Software Version: AECworks v11.51 Date: 2022/12/05 10:07:55 YVWE Chiller Performance Specification Project information Project Name: Location: Engineer: Contractor: Factory: GBI Sold To: Customer Purchase Order No.: Customer Contract No.: Order Date: 2022/12/02 Unit Tag Qty Model No. Capacity (Ton) Power Supply Refrigerant CH-300TR-712-1 1 YVWE355CA50A22WAX 300.0 380V/3Ph/50Hz R-134a Unit Data Evaporator Condenser EFT (°F): 53.60 86.00 LFT (°F): 44.60 95.00 Flow Rate (GPM): 797.4 936.6 Pressure Drop (ft water): 21.5 21.0 Water Water 2 2 0.000100 0.000250 0.025" Enhanced Boling Copper 0.025" CSL Enhanced Copper Design Working Pressure (psig): 150 150 Water Box Weight, ea (kg) : 53 77 Return Head Weight (kg): 24 41 Fluid Type (%): Circuit No. of Passes: Fouling Factor (hr•ft²F/Btu): Tube Description: Water Weight (kg): 776 Performance Data Other Input Power (kW): 174.0 Operating Wt. (kg): 7616 Efficiency(kW/TR): 0.5800 Shipping Wt. (kg): 6840 NPLV.IP(kW/TR): 0.3540 Each Isolator Avg (kg): 1904 Heat Rejection(Btu/h): 4.194 Refrigerant Wt. (kg): 280 Oil Charge (L): 40 Harmonic Filter: No Variable Vi: No Sound Pressure Level(dBA): 82 Electrical Data Comp FLA1#2#: 293 Min. Circuit Ampacity:** 675 Comp MLA1#2#:* 540 Min Fuse/CB Rating:** 800 Comp LRA1#2#: 2754 Max. Fuse/CB Rating: 1200 Type Starter: VSD VSD Hz: 42.2 * MLA Value is the maximum current Amp. of the compressor running at the boundary of the operation map. Printed: 12/5/2022 10:07:58 AM PERFORMANCE SPECIFICATION Page 1 of 2 Software Version: AECworks v11.51 Date: 2022/12/05 10:07:55 **The MCA and Min fuse/CB rating is based on the chiller's MLA to insure every possible conditions and (worst) cases. Each region and country may have different regulations regarding the MCA and fuse/CB sizing. The consultant can judge the preferable size depends on the local regulation and project request. Partload Performance % Load Capacity Input Power EEFT ELFT Evap. PD Evap. Flow CEFT CLFT Efficiency % Ton kW °F °F ft water GPM °F °F kW/TR 100.0 300.0 174.0 53.60 44.60 21.5 797.3 86.00 94.99 0.5800 90.0 270.0 149.0 53.60 44.60 17.8 717.6 86.00 94.04 0.5517 80.0 240.0 127.6 53.60 44.60 14.4 637.9 86.00 93.11 0.5318 70.0 210.0 110.2 53.60 44.60 11.3 558.1 86.00 92.21 0.5248 60.0 180.0 93.46 53.60 44.60 8.60 478.4 86.00 91.32 0.5192 50.0 150.0 79.29 53.60 44.60 6.21 398.7 86.00 90.44 0.5286 40.0 120.0 65.48 53.60 44.60 4.17 318.9 86.00 89.57 0.5456 30.0 90.00 46.73 53.60 44.60 2.42 239.2 86.00 88.66 0.5192 20.0 60.00 40.57 53.13 44.60 1.20 168.2 86.00 87.84 0.6762 18.2 54.50 41.79 52.35 44.60 1.20 168.2 86.00 87.71 0.7668 Notes: Certified in accordance with the AHRI Water-Cooled Water-Chilling and Heat Pump Water-Heating Packages Using Vapor Compression Cycle Certification Program, which is based on AHRI Standard 550/590 (I-P) and AHRI Standard 551/591 (SI). Certified units may be found in the AHRI Directory at www.ahridirectory.org. Auxiliary components included in total KW - oil pump & heater,chiller controls. Printed: 12/5/2022 10:07:58 AM PERFORMANCE SPECIFICATION Page 2 of 2