Uploaded by wal wal

baseband52125216-integration

advertisement
BASEBAND5212&5216
INTEGRATION
Pre-requisite
Category
Netconf
(XML)
Script
MOS
Script
Item
Format
RbsSummary File
Netconf (xml)
SiteBasic Template
Netconf (xml)
SiteEquipment Template
Netconf (xml)
TN Template
Netconf (xml)
RN Template
Netconf (xml)
Feature Activation Script
Moshell (.mos)
Post Integration Script
Moshell (.mos)
Cell Relation Script
Moshell (.mos)
UP
Upgrade Package (UP)
ZIP
LKF
License Key File (LKF)
XML
PC
Client PC
Cable
Ethernet Cable
Comment
Baseband LMT - PC
Pre-requisite
› Baseband5216 should be installed in RBS6601 and
should be power on.
› Scripts and UP package prepared and stored in Client
PC
› SFTP Server installed in Client PC
› Cygwin and moshell for latest version
Client PC Setup (1)
› Client PC connects to Baseband5216 LMT port
› Set Client PC IP address
- IP Address : 169.254.2.1
- Subnet mask : 255.255.0.0
- Default gateway : 169.254.2.2
Client PC Setup (2)
› Stop Symantec Management
› Stop firewall
Right click the icon of Symantec and waiting until
‘Disabled Symantec Endpoint Protection’ available to click
Client PC Setup (3)
› Client PC SFTP Server Setting
- IP Address : 169.254.2.1
- Username : ftp
- Password : ftp
› Save integration files (XML, UP, MOS) to SFTP HOME
Directory
› Turn on SFTP Server
Semi auto-integration(pre-check)
› Check following from “xxx_RbsSummaryFile.xml” XML
script
Semi auto-integration
› Auto-Integration Tool Page
Recommand explorer: google chrome
- Tool Web Page : https://169.254.2.2:8080 (Before Integration)
https://169.254.2.2/autointegration.html
›
https://169.254.2.2
(After Integration)
• Host : 169.254.2.1
• Username : ftp
• Password : ftp
• Site Installation File :
<File_Name>
Semi auto-integration
› Click ‘Downloading Files’ (finish within 10 mins)
SW Package Download
success (Finished)
Prepare Filesystem
success (Finished)
Unpack and Install SW
success (Successful)
Semi auto-integration
› After UP Installation, shows ‘Download Completed’
‘Integrate’ button is activated and click it to integrate
Semi auto-integration
› After press “Integrate” button Node will Restart and start integrate
Configuration File
› In case error happens during integration, integration should be
stopped and board will restore to factory setting. ESI log could be
collected for integration failure.
› If integration finishes with no error no progress message in AutoIntegration Log
› Wait until TN port LED is ON and access node with moshell to run
scripts.
Semi auto-Integration
• After Auto-Integration finishes, logon with moshell. Need to put in
“Username/Password” after “lt all”
Maintenance User Id/Password: “rbs/rbs”
Type rbs/rbs
Run TN/RN Script
• Open an Terminal and run following TN/RN script running
commands
• File path should be put in correctly.
ssh -o PubKeyAuthentication=no -o UserKnownHostsFile=/dev/null -o ForwardX11=no -p 830
rbs@169.254.2.2 –s <TN XML Script File Name>
ssh -o PubKeyAuthentication=no -o UserKnownHostsFile=/dev/null -o ForwardX11=no -p 830
rbs@169.254.2.2 –s <RN XML Script File Name>
• Command Example
ssh -o PubKeyAuthentication=no -o UserKnownHostsFile=/dev/null -o ForwardX11=no -p 830
rbs@169.254.2.2 -s netconf < 3_eNB12_TN_netconfv2.xml
ssh -o PubKeyAuthentication=no -o UserKnownHostsFile=/dev/null -o ForwardX11=no -p 830
rbs@169.254.2.2 -s netconf < 4_eNB12_RBS6601_RN_netconfv2.xml
Contact DT responsible in case error happens with script running.
Run Post Integration Script
• Logon with moshell and run Post Integration Script
• Run script with following command
run <script_name>
• Run script example
run 5_featureActivation.mos
run 6_PostIntegration.mos
run 7_eutranfreq.mos
• After script running, “lt all” to load new configuration and save CV
cvmk <cv_name>
or
acc BrM=1,BrmBackupManager=1 createBackup
cvmk <cv_name> or acc BrM=1,BrmBackupManager=1 createBackup
Post-Check
• After save CV, Node Cold Restart
acc FieldReplaceableUnit=1 restartUnit
• After node is up, check following with moshell
-
Unlock TermPointToMME, EUtranCellFDD
MME, EUtranCellFDD, Sector, SectorCarrier, Radio Unit Status
“inv” to check License Status
Node configuration parameter and System Constant Status
Alarm Status
Save CV
Command list for baseband
####### General ########
G1
cvls
st cell
st ru
lh ru lmclist
vols
get Subrack=1,Slot=1 productData
al
pst
cabx
hget ^EUtranCellFDD CellIdGroup|SubCellId
get . earfcn
G2
cvls
st cell
st ru
lh ru lmclist
/sysm/discspace
space must be below 80%, otherwise remove logs and
UPs
( use /sysm/discspace –c. But be aware that you then
remove all PMDs. Best is to remove PMDs as soon as
you have disk full alarm. )
get Equipment=1,FieldReplaceableUnit=1 productData
al
pst
command is currently not supported on COM nodes
hget ^EUtranCellFDD CellIdGroup|SubCellId
get . earfcn
Command list for baseband
####### SCTP ######
G1
G2
get . initialAdRecWin
get . numberOfAssociations
get . initARWnd
sctp -config | grep -i "SCTP_SYS_PAR_NUMBER_OF_ASSOCS"
####### SC #########
G1
G2
fget NodeManagementFunction=1,SystemConstants=1 systConstants sysconread
####### sCell #######
G1
get . scellc 1
G2
get . scellc 1
####### Feature License ########
G1
inv
G2
inv
Download