Control of 3-phase synchronous generator Using a 3-phase induction motor to rotate the generator shaft Parameters Generator: Sn=300 VA; fn=50 Hz; Vn=380 V; Y-connection; In 0.55 A; N=3000 rpm; Iex=If 0.4 A; Vex=Vf=190 V; Load: resistors (3 resistors; Y-connection) with 7 levels; IL 0.55 A; Induction motor: 300W; 220/380 V; 2/1.1 A; 2650 rpm; -connection Inverter Mitsubishi D700-SC: Input: V1p=220V; 50Hz; Output: 3*240V; f=0-60 Hz; (Ex. 3: regulating frequency with the adjuster (vol); fmax=60 Hz) Generator: Sn=300 VA; fn=50 Hz; Vn=380 V; Y-connection; In 0.55 A; N=3000 rpm; Iex=If 0.4 A; Vex=Vf=190 V; Load: resistors (3 resistors; Y-connection) with 7 levels; IL 0.55 A; Principle diagram Induction motor: 300W; 220/380 V; 2/1.1 A; 2650 rpm; connection Synchronous machine I <=0.55 A Inverter Mitsubishi D700-SC: Input: V1p=220V; 50Hz; Output: 3*220V; f=0-60 Hz; Y-connection (Ex. 3: regulating frequency with the adjuster (vol); fmax=60 Hz) I <=2 A L1 V1p=220 VAC N Inverter Mitsubishi D700-SC U V V1 W W1 220V (FR-D720S-025SC-EC) Ex:3; fmax=60 Hz Shaft U1 L1 V1 L2 W1 L3 (coupling) AC 3-phase analyzer NG -connection V I <=0.4 A +E NG L1 L2 L3 3-resistor Load Max=300 W NL Y-connection A Monitoring output current and frequency I <=2 A 7-level 380V n ~ 3000 rpm U1 I <=0.55 A -E Neutral DC voltage ~ 150V; (insert a low-pass filer) Field Neutral Report sample (link: bit.ly/3EOD1Tm) Let define the steps of control and operation Results and discussion