ELECTRICAL MACHINES ARMATURE DESIGN Submitted by: Gutierrez, Rojay Z. Submitted to: Engr. Lorenzo L. Moricho ARMATURE DESIGN SPECIFICATIONS Double Layer Triplex - Lap Winding (Progressive Winding) Slots (S) = 12 slots Segments = 24 segments Plex (m) = 3 (Triplex - Lap) Poles(P) = 2 Poles Total no. Of Armature Conductors (Z) = No. Of slot x No. of conductors/slot=12x4=48 CALCULATIONS Coil span: 𝑆 12 𝑃 2 𝑌𝑠 = ; = 𝟔 slots per conductor Commutator pitch: Yc = ±m = ± 3 Pole pitch: 𝑍 48 𝑃 2 𝑌𝑝 = ; = 𝟐𝟒 conductor per pole Back pitch: Front pitch: 𝑍 48 𝑃 2 .𝑌𝑏 = + 𝑚; + 3 = 𝟐𝟕 Average pitch:. .𝑌𝑎𝑣 = 𝑌𝑏+𝑌𝑓 2 ; 𝑍 48 𝑃 2 𝑌𝑓 = − 𝑚; − 3 = 𝟐𝟏 Resultant pitch: 27+21 2 = 𝟐𝟒 Reentrancy Yc = 3; Reentrancy = 3 𝑌𝑅 = 𝑌𝑏 − 𝑌𝑓 ; 27 − 21 = 𝟔 Parallel paths a = m(P); 3(2) = 6 WINDING TABLE Yc = 3 1 4 7 10 13 16 19 22 2 5 8 11 14 17 20 23 3 6 9 12 15 18 21 24 Yb = +27 1 to (1+27) = 28 7 to (7+27) = 34 13 to (13+27) = 40 19 to (19+27) = 46 25 to (25+27) = 52-48 = 4 31 to (31+27) = 58-48 = 10 37 to (37+27) = 64-48 = 16 43 to (43+27) = 70-48 = 22 3 to (3+27) = 30 9 to (9+27) = 36 15 to (15+27) = 42 21 to (21+27) = 48 27 to (27+27) = 54-48 = 6 33 to (33+27) = 60-48 = 12 39 to (39+27) = 66-48 = 18 45 to (45+27) = 72-48 = 24 5 to (5+27) = 32 11 to (11+27) = 38 17 to (17+27) = 44 23 to (23+27) = 50-48 = 2 29 to (29+27) = 56-48 = 8 35 to (35+27) = 62-48 = 14 41 to (41+27) = 68-48 = 20 47 to (47+27) = 74-48 = 26 Yf= -21 28 to (28-21) = 7 34 to (34-21) = 13 40 to (40-21) = 19 46 to (46-21) = 25 4 to (52-21) = 31 10 to (58-21) = 37 16 to (64-21) = 43 22 to (22-21) = 1 30 to (30-21) = 9 36 to (36-21) = 15 42 to (42-21) = 21 48 to (48-21) = 27 6 to (54-21) = 33 12 to (60-21) = 39 18 to (66-21) = 45 24 to ( 24-21) = 3 32 to (32-21) = 11 38 to (38-21) = 17 44 to (44-21) = 23 2 to (50-21) = 29 8 to (56-21) = 35 14 to (62-21) = 41 20 to (68-21) = 47 26 to (26-21) = 5