Blue Point Engineering Design D www.BPEsolutions.com Pointing the Way to Solutions! R-C Snubber Noise and Arc Suppressor The R-C Snubber is in t ended t o suppress t he “ induc t ive kick back ” f rom mo t ors, solenoids, relay coils, pumps or any device t ha t crea t es an elec t ro-magne t ic collapsing field. High energy noise spikes are genera t ed whenever curren t is in t errup t ed t hrough an induc t ive load connec t ed t o a swi t ching circui t . These elec t ro-magne t ic noise spikes (EMI) may in t er fere wi t h elec t ronics equipmen t causing erra t ic opera t ion, CPU failure and may also accelera t e relay con t ac t wear. Applied across an induc t ive load, t he R-C snubber suppresses t he elec t rical noise spikes t o elec t ronics and ex t ends con t ac t life on mechanical relays. B A RC Snubber Network A B Red Lion Part No= SNUB0000 RC Snubber Network Part RC Snubber Network Part Resistor Capacitor Relay Contacts A/B EMI - EMF B/A (NO) A/B B/A Motor, Pump, Relay, Solenoid Supply Voltage Switch RELAY AC -orDC Inductive Load R-C snubber applied with the suppressor directly across the inductive load contacts EMI= Elec t ro-Magne t ic in t er ference Blue Point Engineering EMF= Elec t ro-Magne t ic Field www.BPEsolutions.com Phone (303) 651-3794 Blue Point Engineering Design D www.BPEsolutions.com Pointing the Way to Solutions! R-C Snubber Noise and Arc Suppressor APPLICATION The inductive load suppressors are effective in both AC and DC Power circuits Preferred Application Method R-C snubber should be applied with the inductive load suppressor directly across the inductive load contacts for best results if possible. Relay, Microprocessor, Switch * Control Contact Supply Power AC or DC Voltage (250V MAX) AC VDC + - EMI - EMF INDUCTIVE Load Motor, Solenoid, Relay, Pump, Coil R-C SNUBBER Component Alternate Application Method Placing the R-C snubber with the inductive load suppressor across the control contacts will also work (* Use a snubber across all contacts in the load circuit) Relay, Microprocessor, Switch * Control Contact EMI - EMF Supply Power AC or DC Voltage (250V MAX) AC R-C SNUBBER Component INDUCTIVE Load Motor, Solenoid, Relay, Pump, Coil VDC + EMI= Elec t ro-Magne t ic in t er ference Blue Point Engineering EMF= Elec t ro-Magne t ic Field www.BPEsolutions.com Phone (303) 651-3794 Blue Point Engineering Design D www.BPEsolutions.com Pointing the Way to Solutions! R-C Snubber Noise and Arc Suppressor APPLICATION MOTOR INDUCTIVE Load Supply Power AC or DC Voltage (250V MAX) AC VDC + - Ro t a t i o n R-C SNUBBER Component As Close to Motor as Possible (+) Supply Power AC or DC Voltage (250V MAX) (-) R-C SNUBBER Component (-) Small Relay Relay Control Coil Side VDC + - AC R-C SNUBBER Component Large Relay N.O. COM N.C. Microprocessor or Switch Controller COM X N.C. N.O. (+) R-C SNUBBER Components EMI= Elec t ro-Magne t ic in t er ference Blue Point Engineering Relay Coil Side Relay Switch Side INDUCTIVE Load EMF= Elec t ro-Magne t ic Field www.BPEsolutions.com Phone (303) 651-3794 Blue Point Engineering Design D www.BPEsolutions.com Pointing the Way to Solutions! R-C Snubber Noise and Arc Suppressor APPLICATION Pneumatic Valve Supply Power AC or DC Voltage (250V MAX) AC + - R-C SNUBBER Component VDC + - Air Supply 5/2 Switching Solenoid Air Valve + INDUCTIVE Load Air Hose Air Hose Air Hose Pneumatic Cylinder (Double Acting) EMI= Elec t ro-Magne t ic in t er ference Blue Point Engineering EMF= Elec t ro-Magne t ic Field www.BPEsolutions.com Phone (303) 651-3794 Blue Point Engineering Design D www.BPEsolutions.com Pointing the Way to Solutions! R-C Snubber Noise and Arc Suppressor APPLICATION R-C SNUBBER Component A INDUCTIVE Load Relay (-) N.O. Microprocessor - COM Controller + N.C. B (+) Relay Coil Side Relay Switch Side B A A B RC Snubber Network EMI= Elec t ro-Magne t ic in t er ference Blue Point Engineering EMF= Elec t ro-Magne t ic Field www.BPEsolutions.com Phone (303) 651-3794