VENTILATION PIPE SOAKAWAY CESS PIT TANK 150mm PERFORATED PVC PIPE 150mm STANDARD JOINT H.C.F. 300 300 300 TYPICAL MANHOLE 800 BENCHING WC 300 FLUSH CISTERN 300 SLUDGE LEVEL TO SOCKAWAY 300 FROM CESS PIT 1100 SECTION Z-Z 6000 300 5050 SOIL PIPE TRENCH 5235 5900 WIRE BALCON 150mm CONCRETE BAFFLE WALL 5700 150mm STANDARD JOINT 300 300 SURFACE DRAIN 100mm VENT PIPE DRAIN COVER R250 1:200 SOIL AND VENT PIPES REQUIRED TO BE CARRIED UP TO AT LEAST 600mm ABOVE ROOF PIECES OF ROCKS 1:200 B WC C NOTE FOR SEPTIC TANK AIR SHOULD BE EXCLUDED FROM THE SEPTIC TANK TO ENCOURAGE THE GROWTH OF AMOEBIC BACTERIA TO LIQUEFY THE SLUDGE AND TO FACILITATE THE FLOW OF THE EFFLUENT ACCUMULATED. GASES ARE EXPECTED TO BE CONNECTED AND EXPELLED THROUGH THE FOUL AIR OUTLET WHICH SHOULD BE CARRIED AT LEAST 600mm ABOVE EAVES AND ITS END PROTECTED AGAINST NESTING OF BIRDS AS SHOWN ON DRAWINGS. DRAIN SHOULD BE GIVEN SUFFICIENT FALL. PIPE JOINTS SHOULD BE PROPERLY MADE TO PREVENT BLOCKING OF THE APPERTURE AND TO EXPEDITE THE ESCAPE OF ACCUMMULATED GAS. TOP OF SEPTIC TANK MUST BE AT 150mm ABOVE FINISHED GROUND LEVEL. E 4200 BAFFLE WALL 150mm PERFORATED PVC PIPE 4000 4000 R.C. SLAB 1650 1700 Z 1700 1300 TO SOCKAWAY 1100 100 1150 INSPECTION CHAMBER B 300 C-C 8500 C E IMPORTANT WHERE TWO OR MORE WATER CLOSETS ARE CONNECTED TO THE SAME SOIL PIPE, THE TRAP OF EACH WATER CLOSET OTHER THAN THE HIGHIEST SHALL BE VENTILATED BY AN ANTI-SYPHON PIPE INTO THE OPEN AIR AT A POINT 900mm ABOVE THE WATER SEAL IN THE HIGHEST WATER CLOSET. THE ANTI-SYPHON AND CONNECTIONS SHALL BE OF 50mm INTERNAL DIAMETER AND CONNECTED TO SOIL STACK AT A POINT NOT LESS THAN 75mm AND NOT MORE THAN 300mm FROM THE HIFHEST PART OF THE WATER SEAL WHICH IS NEARER TO THE SOIL STACK. OVERALL DEPTH OF SEPTIC TANK BELOW GROUND LEVEL IS DETERMINED BY THE DEPTH OF THE INLET AND SHALL NOT BE LESS THAN 150mm. BAFFLE SCREEN MUST BE PROVIDE TO PREVENT THE FLOW SPLASHING VOILENTLY THUR ALLOWING EASY SUBMERSION AND TO PREVENT DIRECT FLOW BETWEEN INLET AND OUTLET. SEPTIC TANK SHOULD BE OPENED EVERY 6 MONTHS AND DEPTH OF TOP CRUST ACCELERATED. IF THIS EXCEEDS 300mm SURPLUS SHOULD BE REMOVED AND BURIED. SOAKAWAY 300 SECTIONS B-B FROM CESS PIT 100 1400 PLAN 4200 1150 1700 SLUDGE LEVEL SLUDGE LEVEL 150mm PERFORATED PVC PIPE STD 150 JOINT 300 4750 300 6000 5400 BAFFLE WALL PERFORATION 3400 4600 300 300 300 3400 4600 300 SEPTIC TANK DETAILS 300 300 P.O. BOX 8303 ACCRA-NORTH TEL: 0262238617 Email: sowetford2003@yahoo.com MR AUGUSTINE DADZIE PROPOSED ONE STOREY SIX ONE BEDROOM APARTMENT AT KOMENDA SEPTIC TANK DETAILS Project number Date Drawn by Checked by AD201220 16d 22 December, 2020 FREDERICK KOFIE Scale 1 : 100