Uploaded by Nicole Glenn Camacho

BASEPLAN STINGRAY CONFIGURATION new-STINGRAY

advertisement
B
A
A
05
07
A
A
B
11
06
WEATHERPROOF
T-CONNECTOR
IP66 RATED
15
DECORATIVE BULB
IN IP65/ IP66 RATED
SOCKET RECEPTACLE
20
B
14
A
DECORATIVE BULB
IN IP65/ IP66 RATED
SOCKET RECEPTACLE
B
04
A
WEATHERPROOF
T-CONNECTOR
IP66 RATED
A
10
B
B
13
2975
03
A
19
17
B
B
18
16
02
21
A
TO CIRCUIT B
09
A
B
08
B
ECB 30AT, 2P
IN NEMA 4X
(CONFIRM LOC.)
1 - 3x3.5mm2
ROYAL CORD
ECB 30AT, 2P
IN NEMA 4X
(CONFIRM LOC.)
A
01
2 - 3x3.5mm2
ROYAL CORD
1 - 3x3.5mm2
ROYAL CORD
Sab
WEATHERPROOF
2-GANG SWITCH
(CONFIRM LOC.)
12
TO CIRCUIT A
B
22
2 - 3x3.5mm2
ROYAL CORD
Sab
WEATHERPROOF
2-GANG SWITCH
(CONFIRM LOC.)
CIRCUIT - A
CIRCUIT - B
LIGHTING LAYOUT CIRCUIT-A
LIGHTING LAYOUT CIRCUIT-B
3-PIN TERMINAL
BLOCK
PG21 CABLE GLAND
LIQUIDTIGHT
MOUNTED ON WIRE ROPE WITH ELEV: 4m +/-5%
02
POST SUPPORT
FOR WIRE ROPE
HEAVY DUTY CABLE TIE
ROYAL CORD
1 -3C -3.5mm2
03
04
05
06
07
08
09
10
T-JOINT IP66
RATED CONNECTOR
13
14
15
PG21 CABLE GLAND
BOTTOM MOUNTED
1400
PG21 CABLE GLAND
BOTTOM MOUNTED
TO NEXT LIGHT BULB
NOTE:
1. SEE T-CONNECTOR JOINT
DIAGRAM FOR TERMINATION
TO LIGHT BULB
20
T-JOINT CONNECTOR DETAILS
EMBEDDED
ROYAL CORD
ROYAL CORD
1 -3C -3.5mm2
ECB 30AT, 2P
IN NEMA 4X ENCLOSURE
(CONFIRM EXACT LOC.)
INDIVIDUAL WIRES
LINE 1, LINE 2 & GROUND
ROYAL CORD
3C x 3.5mm2
11
19
PG21 CABLE GLAND
LIQUIDTIGHT
PG21 CABLE GLAND
LIQUIDTIGHT
ROYAL CORD
2 -3C -3.5mm2
ECB
G
T-JOINT CONNECTOR
HOUSING
01
30AT,2P
NEMA4X
G
FROM ECB / SWITCH
DECORATIVE
LIGHT BULB IN IP65/66
SOCKET RECEPTACLE
TO TAPPING PT.
R
B
B
R G B
CIRCUIT - A
WIRE ROPE
ROYAL CORD
3C -3.5mm2
R
CIRCUIT - B
2G SWITCH
ECB
12
16
17
18
21
30AT, 2P, 230V
60HZ MCB
NEMA4X ENC.
22
L1
L2
Sa
WP, PLASTIC
W/ COVER
Sb
Sab
DECORATIVE LIGHT BULB DIAGRAM FOR LOCATION 1
2-GANG SWITCH IN
WEATHERPROOF COVER/ENCLOSURE
CONFIRM EXACT LOC. AND HEIGHT (MIN: 1200mm fr. FF)
GROUNDING
PEDESTAL
EXISTING STRUCTURE /BUILDING
G
L1
NOTE:
GROUND LEVEL
L2
G
1. BOTTOM MOUNTED PG21 CABLE
GLAND IN ALL ENCLOSURES
LOCKNUT
2. LOCATION 1 DECORATIVE LIGHT
BULB QUANTITY: 22PCS
PG21 CABLE GLAND
LIQUIDTIGHT
LOCKNUT
RUBBER GASKET
FOR LIQUIDTIGHT
RUBBER GASKET
FOR LIQUIDTIGHT
PG21 CABLE GLAND
LIQUIDTIGHT
TO CIRCUIT A
TO CIRCUIT B
ENCLOSURE & CABLE GLAND
INSTALLATION DETAILS
RISER / SINGLE LINE DIAGRAM
SCHEDULE OF LOADS
VOLTAGE DROP CALCULATION
PROJECT TITLE:
PROFESSIONAL ELECTRICAL ENGINEER
PRC NO:
PTR NO:
VALIDITY:
TIN:
PROPOSED STINGRAY CONFIGURATION
ELECTRICAL PLAN - LOCATION 1
LOCATION:
SHEET CONTENTS:
- SCHEDULE OF
- LIGHTING LAYOUT CIRCUIT-A
LOADS
- LIGHTING LAYOUT CIRCUIT-B
- RISER/SINGLE LINE DIAGRAM - VOLTAGE DROP
CALCULATION
- INSTALLATION DETAILS
EE
01
Download