Uploaded by shxzmd

UMG WH6-xx WN6-xx WS6-xx Compass Pro LR

advertisement
Line 6000
Washers
CompassPro
Essentia
User maintenance guide
5
8
Performance maintenance programmes
4
In order to ensure the safety and performance of your equipment,
it is recommended that regular service is undertaken every
12 months by Electrolux Professional authorised engineers
in accordance with the manufacturer recommendations.
Please contact your local Electrolux Professional Service
Centre for further details of service agreements available.
7
Suggested for you
2
1
For more Accessories & Consumables
please look at our Catalogues or contact
our Electrolux Professional Service Partner
or visit https://buy.electroluxprofessional.com
9
3
6
1
heck that there are no foreign objects inside
C
the drum before loading.
daily
6
lean the drain outlet hose from
C
lint and debree.
2
heck that the door cannot be opened
C
when the program has started.
daily
7
un a high temperature program and add
R
deliming agent to clean elements and interior
of drum from lime.
6
3
lean the drum opening and door gasket
C
from lint. Check that there is no leakage.
daily
8
Clean water inlet filters.
every
months
4
5
lean the exterior of the machine with
C
a soft cloth.
daily
lean the detergent container from
C
chemical residue.
daily
9
Clean the heating elements from lint.
(Mop machines).
every
months
3
0W1Y2F
Working Table
Water soluble bags
(25 bags)
Canvas Trolley
RV-74 - 200 lt
Stainless Steel
Trolley BV-220/BV
131 lt
every
months
6
every
months
6
0W1Y2H
1000 x 700 x 850
0W1Y2J
1500 x 700 x 850
0W1Y2K
2000 x 700 x 850
0W7S9D
Cleaning external surfaces
Wash the external surfaces with warm, soapy water. Avoid using detergents containing abrasive substances, steel wool, brushes or steel scrapers. Rinse with a damp
cloth and dry carefully. Avoid using chlorine or ammonia-based products. Clean the control panel with a soft cloth dampened with water and, if necessary with neutral
detergent. Do not wash the equipment with direct or high pressure jets of water. With the aim of reducing the emission of polluting substances into the atmosphere, it
is advisable to clean the equipment (externally and, when neccessary, internally) with products that have a biodegradability exceeding 90%. Electrolux Professional
strongly recommends to use Electrolux Professional approved cleaning agents, rinse and descaling agents to obtain better results and maintain product efficiency
over time. Damages caused by cleaning, as a consequence of use of not approved cleaning agents, rinse and descaling, will be excluded by the warranty.
The operations described must be performed wearing the needed Personal Protection Equipment. Refer to the User Manual.
05UMW12____ENG00L6CPRO
0W1XFY
2021-12-14
All purpose
Microfibre cloth
0W1XXU (S)
660 x 840 mm
0W1XXV (M)
710 x 990 mm
0W1XXW (L)
910 x 990 mm
0W1Y2B
Spring Trolley
229 lt
Essentia
Anomaly
Description
Instructions to user
Error 11:1
No water
Water level is not reached withing set time. Check that the water tap is fully open.
Press the start button to resume program.
Error 11:2
No heating
It has taken too long for the machine to warm up the water. The machine can still be used but will soon
need service.
Press the start button to resume program.
Error 11:8
Door open
The door was not closed properly. Open and close the door again.
Press the start button to resume program.
Error 20:1
O.H. Motor
The motor is overheated. Switch off the machine for 30 minutes and restart the program.
If the problem persists, contact authorized service.
Error 21:1
Heatsink too hot
The motor control unit (MCU) is overheated. Switch off the machine for 30 minutes and restart the program.
If the problem persists, contact authorized service.
Error 21:2
Motor too hot
The motor is overheated. Switch off the machine for 30 minutes and restart the program.
If the problem persists, contact authorized service.
Error 23:1
Heatsink too hot
The motor control unit (MCU) is overheated. Switch off the machine for 30 minutes and restart the program.
If the problem persists, contact authorized service.
Error 23:2
Motor too hot
The motor is overheated. Switch off the machine for 30 minutes and restart the program.
If the problem persists, contact authorized service.
CMIS communication error
Communication with connectivity system was interrupted. The machine can still be used, but will not send
data to connectivity system. Press the start button to resume program.
Try to resume communication by switching off the machine for 30 seconds and restart the program.
If the problem persists, contact authorized service.
DMIS communication error
Communication with dosing system was interrupted. The machine can still be used, but might not dose
chemicals correctly. Press the start button to resume program. Try to resume communication by switching
off the machine for 30 seconds and restart the program.
If the problem persists, contact authorized service.
Error 52:1
Error 52:2
Download