A-Series Lighting Control Panel with Remotely Operated Circuit Breakers (ROCB) 1 ROCB Panel A-Series Lighting Control Panel with Remote Operated Circuit Breakers Factors Driving Use Continued Rise in Energy Costs Market Adopting Energy Efficient Codes Integration of Systems within Facilities Lighting is 30% of energy cost for Commercial Benefits • Reduced Energy Cost •Reduced Lighting Cost (Extend lamp life, lower maintenance cost) • Short Circuit Protection and Remote Control • Maximizes Lighting Effectiveness and Property Security At Min. Cost. 2 ROCB Panel Remote Operated Circuit Breaker Overview + = 3 ROCB Panel Remote Operated Circuit Breaker Overview Remotely Operated Circuit Breaker: Amps: 15, 20, 30A Volts: 120/240, 208Y/120, 277/480VAC Status Indicator Green – open White - closed Poles: 1 and 2 Pole UL: 489 Certified 20 Year Life reliability 50,000 operations under full load Bolt On Line strap Unidirectional Motor Floating Control Pin for Electrical Connection Snap on Clip Aux Switch for Contact Status, linked to Contact Arm 4 ROCB Panel A-Series Lighting Control Panel Overview TEYRC: Remote Operated Circuit Breaker Backplane: PC Boards Houses Breaker Input/Output Connections and Controller Plug-In Interface Cable: DB 25 straight thru Cable connection Integral Controller: Schedules and Controls Breakers Class 2 Transformer: Fed Off Main Bus To Power Controller 5 ROCB Panel A-Series Lighting Control Panel Overview Panel Highlights • TEYRC and TEY branch breakers • THQBGF / THQBGFEP available @ 120/208V • Maximum branch ampacity = 150A Capability to mount standard TEY breakers • Main bus ratings up to 400A UL • Subfeed Breaker Combinations: • (1) SF @ 225A and (1) TED @ 150A Capability to mount 240V Ground Fault 6 ROCB Panel Controller Overview Controller: (Internal Firmware) • Open Protocol; Native BacNet & Modbus • 16 Time of Day, On/Off Scheduling •Day of week repeating schedule • 16 Lighting Zones/groups of control • Real Time & Astronomical Clock • Holidays Control Override • Leap Year & Day Light Savings Time Controller: (Internal Hardware) • 16 Digital Inputs, 2 or 3 wire • 3 Analog Inputs • Auto Flip • Off Warning (flick) • Self Diagnostics, Breaker contact status • Burn Hour Tracking, Load Priority Management • Event alarm and recovery • Battery back-up •Daylight Optimization Module 7 ROCB Panel Controller 16 Digital Inputs Auto Flip Battery Backup Addressable Dip Switch Analog Inputs Hand-held Programmer Port Alarm Output Local Overrides 8 ROCB Panel Controller Comm RS232 Programming port Ethernet port (Optional – highly recommend on at least 1 ROCB per system) RS485 Net 1 For multiple ROCB RS485 Net2 for Daylight & Sw Modules 9 ROCB Panel A-Series Lighting Control Panelboard Section 9 BuyLog 10 ROCB Panel Lighting Control Panel: How to Review Standard TEY Breaker Int Control w/Ethernet RC = ROCB Breaker Approval Drawing 11 ROCB Panel Controller Set-up and Configuration Hand Held Programmer Software Programming 12 ROCB Panel 13 ROCB Panel 14 ROCB Panel 15 ROCB Panel 16 ROCB Panel ROCB PANEL WORKSHEET Notes: 1) 2) 3) 4) RJC FEB,06 This is a worksheet for basic functions, see instruction book for details and more complex functions. Decide which circuits will be controlled at the same time, put these in group. Max 16 groups per panel, groups can be inside groups. Decide how a group will be controlled: hard wire input, time of day schedule, Astrological time for location, or photo cell. Fill out schedule with on periods of lights, max 8 per day. Max 16 schedules/panel. Lighting Group No (ZN01 to ZN16) ___________LTG Grp (Can be breakers in this panel or other panel; or other groups.) I/O Definition Lighting Outputs (Select which breakers will be in a group of control) Breaker No Panel No Circuit description Configuration Flick Warning Enable___ Minutes before off ____(Will blink lights before shutting them off.) Input_____Time_____(ex Switch to turn lgts on if working late) Override (Can control on, off or both) Schedule No / ______ On_____ Off_____ (See Schedule below.) or Input No On_____ On offset______min Off______ Off offset____min Astro Astro clock based on location (ex Cleveland, OH), can control on, off or both Input_____On_____ Off_____ (Can control on, off or both) Photo Cell Schedule No (SchA to SchP) ___________ Daily Schedule Sunday Monday Tuesday Wednesday Thursday Friday Saturday Holiday CAL 1 Holiday CAL 2 On_____ On_____ On_____ On_____ On_____ On_____ On_____ Y/N_____ Y/N_____ (Set on/off times for each day of week, max 8 on/off per day) Off_____ On_____ Off_____ On_____ Off_____ On_____ Off_____ On_____ Off_____ On_____ Off_____ On_____ Off_____ On_____ Off_____ On_____ Off_____ On_____ Off_____ On_____ Off_____ On_____ Off_____ On_____ Off_____ On_____ Off_____ On_____ Off_____ On_____ Off_____ On_____ Off_____ On_____ Off_____ On_____ Off_____ On_____ Off_____ On_____ Off_____ On_____ (Sub Schedule to control lights on a holiday) (Sub Schedule to control lights on a holiday) Off_____ Off_____ Off_____ Off_____ Off_____ Off_____ Off_____ 17 ROCB Panel ROCB PANEL WORKSHEET Panel 200 (LP4-P2) Notes: 1) 2) ROCB Panel Address 3) 4) RJC This is a worksheet for basic functions, see instruction book for details and more complex functions. Decide which circuits will be controlled at the same time, put these in group. Max 16 groups per panel, groups can be inside groups. Decide how a group will be controlled: hard wire input, time of day schedule, Astrological time for location, or photo cell. Fill out schedule with on periods of lights, max 8 per day. Max 16 schedules/panel. Lighting Group No (ZN01 to ZN16) ___ZN02____LTG Grp 2 Pole Breakers In Group Used Astro Clock I/O Definition Lighting Outputs Breaker No Panel No 7,9 200 11,13 200 15,17 200 8,10 200 12,14 200 (Can be breakers in this panel or other panel; or other groups.) (Select which breakers will be in a group of control) Circuit description Site Poles Site Poles Site Poles Site Poles Site Poles Configuration Flick Warning Enable___ No Can't use with Metal Halide fixtures Input_____Time_____Not used Override Not used Schedule No / ______ On_____ Off_____ Not used or Input No Astro HID – No flick warning ON YES On offset 60 min Off YES Off offset 60 min Astro clock based on location Erie, PA Photo Cell Input_____On_____ Off_____ Not used Schedule No (SchA to SchP) Not Used 18 ROCB Panel PROGRAMMABLE PANEL WORKSHEET 02/21/2006 Lighting Group # ZN01 Breaker No 2,4 6,8 10,12 16,18 20,22 24,26 28,30 32,34 36,38 Panel No A A A A A A A A A Added 14 A Circuit description SITE LIGHTING POLES SITE LIGHTING POLES SITE LIGHTING POLES SITE LIGHTING POLES SITE LIGHTING POLES SITE LIGHTING POLES SITE LIGHTING POLES SITE LIGHTING POLES SITE LIGHTING POLES Sign@ Whipple Ave Configuration Flick Warning Override Schedule No / or Input No Astro NO - not capable with metal halide fixtures NO SEE PHOTOCELL INPUT BELOW Photo Cell Lights will be on from dusk-to-dawn and also on gloomy days, based on the photocell. NO Used input 101, wired as maintained 2 wire input. Photo Cell Connected to 1 of 16 Inputs 19 ROCB Panel School Lighting Control System With 4 ROCB’s Address Set w/ Dip Switch ROCB PANEL 100 ROCB PANEL 200 Line Circuit Breaker Building Automation System Line Load Circuit Breaker ON OFF Status Controller Controller ROCB PANEL 400 Line Load Circuit Breaker ON OFF Status Panel Ethernet ROCB PANEL 300 Line Load Circuit Breaker ON OFF Status Controller Panel ON OFF Status Controller Panel Ethernet Or Net 1 Ethernet Or Net 1 RS485 RS485 Load Panel Ethernet Or Net 1 RS485 20 ROCB Panel A-Series Lighting Control Panel with Remote Operated Circuit Breakers Specifying Tips Use internal controller (If space allows) with Ethernet Spec panel with TVSS (To protect electronic ballast) Spec Software (Provides backup file) or Hand Held Programmer to configure panel. Spec Factory Programming (Provide control scheme desired or must be quoted at a latter time.) Spec On-site System commissioning (Particularly for larger jobs or BAS interface.) Analysis and Benefits • Compare Installed Cost – ROCB vs. Lighting Panel w/Relay Panel w/Interconnection • Lighting Control w/ communication, lamp burn info, flexible, expandable. • Install ROCB to meet energy code, configure and define as building use grows. 21 ROCB Panel