Ericsson Command Handling
1. Giving Performance test against a TRX
rxbli:mo=rxotrx-395-5; (Block)
rxtei:mo=rxotrx-395-5; (Perf. Test)
rxble:mo=rxotrx-395-5; (Deblock)
2. To see the frequency state of a TRX(With fault code)
rxmfp:mo=rxotrx-395-5;
3. To see TRX status
1. rxmsp:mo=rxotrx-395-5; (For having only one TRX status)
2. rxmsp:mo=rxotrx-395-4&&-5; (for having two or more TRX status
4. To see all (TX,TS,TRX) status
rxmsp:mo=rxotrx-395-5,subord;
Note: State, BLO, BLA all the values will be zero for active TRX (TRX in good condition)
5. To find the TG value of a Site
rxtcp:moty=rxotg , cell=dx03214;
6. To see all external alarm of a BSC
allip:alcat=bts;
7. To see all internal alarm of a BSC
allip:alcat=sw_dev;
8. To see active alarm of a BSC
allip;
allip:acl=a1;
allip:acl=a2;
allip:acl=a3;
allip:acl=a1,alcat=ext/bts;
(For all the active alarm of a BSC)
(where a1=critical alarm only)
(where a2=major alarm only)
(where a3=minor alarm only)
(for critical ext alarms)
9. To see the total number of TRX of a Site
rxcdp:mo=rxotg-27,details; (where 27 is the TG value of 900B of a site.)
10. Block-Deblock of a TRX
rxbli:mo=rxotrx-23-0,subord; (Block)
rxese:mo=rxotrx-23-0,subord; (Reload Order)
rxesi:mo=rxotrx-23-0,subord; (Reload Execute)
rxble:mo=rxotrx-23-0,subord;(Deblock)
11. TRX no. of 900B and 1800B
900B Cell
1800B Cell
1
2
3
1
2
3
0
1
2
3
4
5
6
7
8
9
10
11
0
1
2
3
4
5
6
7
8
9
10
11
(No. of Cell)
|
|
| (No.
12. To find out The RBL2,RBLTB,RBLT2 number of a Specific site
a) rxapp:mo=rxotg-353; where 353 is the TG value of a site
b) ntcop:snt=all;
Note: Searching format to find out the Fault description, Action from the PDF file: No of class: fault
code. Example: 1B:33, 2A:30
13. To see the GPRS Status of a BSC
rrgbp;
14. Lock-unlock of a TRX(including all TX,TS etc corresponding the TRX)
rxbli:mo=rxotrx-23-0,subord; (Lock)
rxble:mo=rxotrx-23-0,subord; (Unlock)
15. Lock-unlock of a TRX(excluding all TX,TS etc corresponding the TRX)
rxbli:mo=rxotrx-23-0; (Lock)
rxble:mo=rxotrx-23-0; (Unlock)
16. Lock – unlock of a cell
rlstc:cell=dx12341,state=halted; (The first cell lock of DHK_X1234 site)
rlstc:cell=dx12341,state=active; (The first cell unlock of DHK_X1234)
rlstc:cell=dx12341,chgr=1,state=active; (The first cell of 1800 band unlock
of DHK_X1234)
17. To check the RBL2 of a site either it is Working or not (Loop check)
dtstp:dip=84rbl2; (where 84 is the rbl2 number of a site)
18.To check PCMS loop from BSC end of a site
dtstp:dip=84rtltb;
19.To check PCMS loop from TRAU end of a site
dtstp:dip=84rtltt;
20.To know the time from the system
caclp;
21.To find the number of traffic channel of a site
rxapp:mo=rxotg-6; where 6 is the TG value.
22. To get all the signaling of a BSC
c7ltp:ls=all;
23. To clear “digital path quality supervision”alarm
dtqsr:dip=all,es;
dtqsr:dip=all,cs2;
dtqsr:dip=all,ses;
dtqsr:dip=all,ses2;
dtqsr:dip=all,sf;
24. To look into either a cell holding call or to see channel status
rlcrp:cell=dx00932;
25. To monitor signaling point
c7spp:sp=all;
27. To know frequency of all BTS in a BSC
1. rlcfp:cell=all; (For all BTS)
2. rlcfp:cell=dx00501; (For a specific cell)
27. To know cell configuration frequency data
rlcfp:cell=dx00931; (Where 1 is for 1st cell of DHK_X0093)
28. To have all the data of a cell
rldep:cell=dx00931;
29. To get either a cell is 900B or 1800B
Lj-l
30. The command to point the connected BSC’s for the TRC
rrbsp;
31. The command of getting the name of MSC to which BSC is connected
rrmbp;
32. To have the name of all MSC
rrmbp:msc=all;
33. To see all PCM status
dtstp:dip=all;
34. To see either a cell is halted or active
rlstp:cell=dx00931;
35. To see the halted cell status of all BTS in a BSC
rlstp:cell=all,state=halted;
37. To know all TRX faults
1. rxasp:moty=rxotrx; (for all kinds of OML fault of a BSC)
2. rxasp:moty=rxotg; (For all kinds of Fault of a BSC)
39. To know either a Site carrying 2E1 or 1E1
rxapp:mo=rxotg-6;
Here 6 is the TG value of the site. If no. of TCH starts from 1 to 31 then 2E1. If starts from 1 to 15
then it will be 1E1 carrying site .
36. To get all PCM status which are down
dtstp:dip=all,state=abl;
38. To know individual TRX fault
rxasp:mo=rxotrx-260-0;
Where 260 is TG value & 0 is for TRX number
40. To have the TEI number of a site
rxmop:mo=rxocf-8;
41. To manually block or unblock a specific rbtl2
1. dtble:dip=78rblt2; (Unblock)
2. dtbli:dip=78rblt2; (block)
42. To have the site ID (name of site) from an unknown TG value
rxasp:mo=rxotg-340;
43: To get the software version of a Site
rxmop:mo=rxotg-8;
44. A TRX having hardware or not
rxmfp:mo=rxotrx-8-0;
If RU Version, Position all values show zero then the TRX is without hardware.
45. To check if AP is up
1) aploc;
2) prcstate –l
AP is equivalent to BAM. APs are redundant.
46.How to find out RALT2 belongs to which BSC
Let’s assume RALT2:49 in TEDHK01
Connect to TEDHK01
ntcop:snt=all;
There will be a DEV list against all DIPs
Against 49RALT2 there will be a range [RALT2-1568&&-1599]
Add 1 with the lower range, which will be 1569 for 49RALT2
racip:dev=RALT2-1569;
The second command will show connected MSC & BSC.
47.To find out under which sector a TRX is
RXMOP:MO=RXOTX-TG-TRX
Elaboration:
TS= Time slot
TX= Transmission of TRX
RX= Receiver of TRX
TG= Transceiver Group
CF= Control Function
TF= Timing Function
IS= Interface SW
Note:
DXU of ericsson site is equivalent to COBA of Siemens
For CDU-G : If TG value is less than 200 then it is 900B else 1800B
For CDU-K : Both bands will have same TG
Sometimes 1800B and 900B are thrown over 1E1 in that case RBLT2 of Both will be same but their
TG value will be different.
If OML fault appears against a TRX or site that means OMC connection is broken for that site or
TRX. So no command will be successful in that case.
One DTRU Contains two TRXs
BTS
!
!------RBLT2
!
BSC
!------RTLTB/RTB/RTB2
!
!------RTLTT/RTT
TRC
!
!------RAL2/RALT2
!
MSC
RAL2/RALT2 equivalent to PCMA
RTLTT/RTT2 equivalent to PCMS
RBL2/RBLT2 equivalent to PCMB
BSC
BSCT01
BSCT03
BSCT04
BSDH04
BSDH06
BSDH17
BSDH20
BSDH26
BSDH30
TRC
TECTY01
TECTY02
TECTY01
TEDHE01
TEDHK01
TEDHC01
TEDHC02
TEDHK01
MSC
MGCT02
MGCT03
MGCT02
MGDH04
MGDH01
MGDH03
MGDH01
MGDH01
MGDH03
Location
Chittagong
Chittagong
Chittagong
CRP-Mirpur
Hosna
Kaderia
Hosna
Hosna
Kaderia
48. To see whether CDU cable is K or G type.
Rxmfp:mo=rxocf-33;
49.To Find out how many ckt are block of a STM( for this command please connected to respective
switch )
Stdsp:dety=rtltt2,bsc=all;
50, To see the trx band(900/1800) here 289 TG value,2b TRX number
RXMOP:MO=RXOTRX-289-2,subord;
51. for circuit measurement:(TRC)
stdsp:dety=rtltt2,bsc=all;
Calculation: NBL/NDV
52. For created but unconfigured TRX Status:
RXMSP:MO = RXOTG-##,SUBORD;
RXESI:MO = RXOTRX-##-##,SUBORD;
RXBLE:MO = RXOTRX-##-##,SUBORD;
53. To find out TG value against a BTS.
Rxtcp:moty=rxotg,cell=dx22661; where dx22661 is cell no.
54. To find out whether is signaling down or not?
Tpcop:sdip=2etm2;
54,………
Rrgbp;
Download