IUSS HEALTH FACILITY GUIDES Building Engineering Services Gazetted 17 February 2014 Task Team: C:03 supported by: f. g. Name and signature of facility representative Dates of test and acceptance by client. 4. Medical gas installations 1. 2. 3. 4. 5. The design parameters for internal spaces should be found in the detailed room-requirement sheets published in the individual IUSS guidance documents of the various functional units. Where these room-requirement sheets are absent or lacking adequate information, the data contained in this document may be used. All units of a health establishment, except sub-acute and hospice facilities, where patients are accommodated and treated, must have medial gases and vacuum provided by medical-grade piped services, with indexed terminal connecter points. Bottle systems may be provided in sub-acute and outpatient facilities. Mobile gas services must be available for crisis situations. Sub-acute facilities must have one mobile oxygen cylinder per 10 patients and one suction machine for every 10 patients. The minimum services to be supplied to all acute care areas are described in Table 11.1. Should the data in this table be in conflict with the table presented in the individual departmental design guidance documents, those individual guidance documents take precedence. TABLE 5: MINIMUM GAS SERVICES Description Major theatre8 Minor theatre8 Cath lab 8 Oxygen HP Air LP Air N2O VAC Theatre panel 1 1 1 1 2 Per pendant 2 2 2 1 2 Theatre panel 1 1 1 1 2 Per pendant 2 2 2 1 2 Theatre panel 1 1 1 1 2 1 1 Per pendant 1 Post operation Bedhead trunking 1 1 1 Procedure room Theatre panel 1 1 2 Resuscitation bay 1 1 2 Delivery room 2 1 2 High-care unit, per bed 1 1 2 Intensive-care unit, per bed 2 2 2 Casualty, per bed 1 1 1 Wards 1 per 2 beds 6. 7. 8. 8In Scavenging 1 1 1 1 per 2 beds A gas alarm system to monitor gases, excluding scavenging, must be installed in a location that is manned 24 hours per day. A slave panel must also be installed in the intensive-care unit and in the theatre complex. This alarm system must be connected to UPS. All piped vacuum and oxygen systems must have mobile back-up systems with adequately trained staff to handle them. The back-up service shall be automatically activated if the line pressure drops below the set operating pressure. All back-up services and change-over valves shall be on UPS and diesel generator supplies. Medical air (low pressure) for respiratory purposes must be provided at a fixed pipeline pressure of 400 kPa. Medical air (high pressure) for driving surgical power tools must be provided at a terminal usage pressure between 700kPa and 1000 kPa, depending on the tools/equipment to be used. The ICU and operating rooms must be cases where a second pendant is installed, the services in the theatre panel can be omitted. INFRASTRUCTURE UNIT SUPPORT SYSTEMS (IUSS) PROJECT Health Facility Guides: Building Engineering Services - Gazetted 17 February 2016 36 1 Procedure rooms 1 Maternity delivery rooms Dialysis Treatment Beds. Note that the equipment can include water heating with high kw loading so care should be taken when sizing the isolating transformers 2 Pendant Panel fed from MIT and UPS Red dedicated SSO with Blue DPS INFRASTRUCTURE UNIT SUPPORT SYSTEMS (IUSS) PROJECT Health Facility Guides: 25 October 2013 Building Engineering Services [APPROVAL V2] 4 x 16A Dedicated per bed on the same isolating transformer but two separate circuits 4 x 16A per bed per two circuits. 2 1 x Red 16A Dedicated 1 x 16A Normal per Station 1 x Red 16A Dedicated for Radiology Procedure Crash Cart Position 1 x 16A Normal per ward for cleaning + 1 x 16A in ceiling for TV point per bed. 2 x 16A per bed 1 x 16A Normal per Ward for Cleaning 1 x 16A Normal per every 15m of corridor for Cleaning 1 x 16A Normal 1 x 16A Normal per Station Dedicated Red SSO fed from UPS on Wall or Power Skirting Location on wall or from UPS on Wall or Power Skirting 4 x 16A Dedicated per bed on the same isolating transformer but two separate circuits (Note if you are using a 8kva isolating transformer you can put 6 beds on one transformer) 0 1 0 1 Casualty treatment Rooms 1 Casualty ward Corridor 0 Rooms Dedicated 125A supply to dedicated Radiology control room Group Description Location Medical Number and type of Switch Socket Outlets (SSO) Hospital Service Panel Bed Head Trunking fed from MIT and Theatre Panel fed Bed Head UPS. 16 A Red from MIT and UPS Trunking backed dedicated SSO with Red dedicated SSO up by Standby Blue DPS9 with Blue DPS 50 On Wall fed from MIT and UPS Red dedicated SSO with Blue DPS