9:35 am Pakistan Time Rfq_19892 - PD/E&I/PT/19892/2022- Supply, Installation And Commissioning Of SCADA System For Adhi Well S5 & S7 Name & Designation Ahsan Ali Hashmi (Sales & Application Engineer II) Buyer Organisation Pakistan Petroleum Limited Date 10/05/2022 9:35:30 am - Time Zone: Pakistan Time Buyer Name Niaz Muhammad [SPO] Division Electrical & Instrument Department Procurement PROJECT INFORMATION Project Code Project Title Project Reference tender_21682 PD/E&I/PT/19892/2022- Supply, Installation and Commissioning of Niaz Muhammad / ADHI / N / NW: SCADA System for Adhi Well S5 & S7 000004014990 / GL: 0900102053 RESPONSE STATUS Response Status No Response Prepared OVERVIEW Code rfq_19892 Title PD/E&I/PT/19892/2022- Supply, Installation and Commissioning of SCADA System for Adhi Well S5 & S7 Description Status Running Supplier Access Press Tender / PPRA Event Currency USD Test RFQ No DATE & TIME INFORMATION Options for Viewing Responses Sealed Publication - Date 06/05/2022 Closing - Date 26/05/2022 Number of Hours before Closing Time to block Expressions of Interest 0 Publication - Time 4:55:30 pm Closing - Time 3:30 pm AWARDING STRATEGY Supplier Response Ranking Scoring Method Maximum Technical Score Best Technical Score Absolute 100 ATTACHMENTS Path root (9) Filename 9.Annex-G.pdf Final.pdf Guidlines for Visitors.pdf Instructions, T&Cs for Procurement of Materials.pdf Instructions, T&Cs for Procurement of Services.pdf Schedule of Payment.pdf SCOPE OF WORK (ITB).pdf Supplier User Guide – Responding to Online Tenders_1.pdf Supplier User Guide – Using the Messaging Tool_1.pdf Description Folder Size 24,556 KB Downloadable Last Modification Date Description File Size No 09/05/2022 IGNORE THIS FILE 206 KB No 09/05/2022 IGNORE THIS FILE 1,943 KB Yes 14/12/2021 18,958 KB Yes 14/12/2021 392 KB Yes 14/12/2021 953 KB Yes 06/05/2022 76 KB Yes 09/05/2022 154 KB Yes 14/12/2021 1,220 KB Yes 14/12/2021 658 KB Technical Envelope 1.1 TERMS: ( Questions: 3 ) 1.2 Questions related to Item Specifications: ( Questions: 1 ) 1.3 Supply, Installation and Commissioning of SCADA System for Adhi Well S5 & S7 ( Questions: 16 ) 1.4 FINANCIAL STATUS OF THE FIRM WITH SUPPORTING DOCUMENTS ( Questions: 4 ) 1.5 General Attachments TECHNICAL ENVELOPE: 1.1 TERMS: - SECTION MAX SCORE = 0 1.1.1 1.1.2 1.1.3 Question DELIVERY: BID VALIDITY Bid Bond Description DELIVERY: BID VALIDITY Attach Scan Copy of Bid Bond (unpriced) Min/Max Score 0/0 0/0 0/0 Response TECHNICAL ENVELOPE: 1.2 QUESTIONS RELATED TO ITEM SPECIFICATIONS: - SECTION MAX SCORE = 0 Question 1.2.1 NOTE Question Description Below is the list of required items. Respond if you are quoting for same specs or a variant. Min/Max Description Response Score 1.2.2 0010179693-99-00010 SCADA System for 02 No Wells. Adhi South S5 & Adhi South S7 0/0 ******************************* REMOTE TERMINAL UNIT (RTU) - QTY 02 Nos. ***************************************** Complete RTU to be supplied, installed, configured & commissioned at 02 Well Sites, and hooked up with existing SCADA MTU HMI at Control Room, on turnkey basis. This specification / scope of works of this project covers the study of the existing SCADA System, all related system engineering works, supply of materials, installation & Commissioning of RTU for the modified SCADA system to incorporate additional well sites viz Adhi South X5, Adhi South X7. 1.0,, GENERAL / EXISTING SYSTEM ********************************* The existing SCADA HMI at control room is running on DeltaV 12.3.1 Version. Presently 30 Wells are being monitored & controlled by SCADA system. The existing Remote Terminal Unit (RTUs) at each Well site comprises of: ·,,Siemens PLC S7-300 & S7-1500 based System ·,,Siemens CP343 Modbus Interface Module ·,,Siemens TP170A Operator Interface Display. ·,,Radio Modem RIPEX, full duplex, with UHF Antenna. ·,,Solar Powered Backup System, 24 VDC system voltage<(>,<)> 6-days backup. ·,,Field equipment's (Per Well Site): ·,,IR Flame Detector-1 No.<(>,<)> ·,,Optical Gas Detector/transmitter-1 Set.<(>,<)> ·,, Exia SOV-4 Nos. ·,,Pressure Switches- 4 Nos. ·,,Smart Pressure Transmitters5 Nos. and ·,,Smart Temperature Transmitters -1 No<(>,<)> ·,,Battery Voltage Monitoring Transducer - 04 No. Complete RTUs for additional 02 well sites (Adhi South X5, Adhi South X7) are to be supplied, installed and hooked up with existing SCADA system of Adhi gas field. Material of new SCADA systems to be supplied, with the RTU, is indicated here under: 2.0,,BILL OF MATERIALS (TYPICAL FOR ONE WELL SITE) ***************************************************** Bill of Material provided .... (Detailed ITB attached) TECHNICAL ENVELOPE: 1.3 SUPPLY, INSTALLATION AND COMMISSIONING OF SCADA SYSTEM FOR ADHI WELL S5 & S7 SECTION MAX SCORE = 0 Min/Max Response Score Compliance / Deviations Vendor has submited "Specifications Compliance / Deviations Sheet" with 0/0 Sheet the bid. Assessment of BOQ Vendor has carried out assessment of mentioned BOQ and include any 0/0 missing component that they feel is necessary for the completion of this system and all such items/services should be quoted separately as an option Quoted complete system Vendor has quoted complete system. 0/0 Vendor cannot submit partial bid (like only quote for solar system, Cables, glands etc are Not Acceptable). Vendor must offer complete solution. Registered Company Bidder must be registered company under company ordinance. 0/0 Established Office Must have well established office(s) in Pakistan to provide required 0/0 services. Offered PLC Bidder has quoted SCADA RTU System based on SIEMENS S7-1500 PLC. 0/0 Relevant Experience Bidder has more than 5 years of experience of in installation / 0/0 commissioning of SCADA System (SIEMENS or Allen Bradley based) with evidence of job completion in different companies have been attached. Job Completion Bidder has provided evidence of installation & startup of SIEMENS or AB 0/0 Certificates for SCADA PLC Based SCADA system (Complete system) in Oil & Gas Company or System installation petroleum refinery in Pakistan. Projects Evidence must be in form of Job completion Certificates. Such evidence shall be provided year-wise, with name of company wherein project has been carried out, description of project and contact person details with valid references. Bidder to submit experience in Tabular form as mentioned in Tender document Section 10. Question 1.3.1 1.3.2 1.3.3 1.3.4 1.3.5 1.3.6 1.3.7 1.3.8 1.3.9 Technical Manpower Resources 1.3.10 Technical Manpower Resources Description PPL may request for the visit and other project evidences. Must have adequate number of manpower resources for the technical support, at site whenever required. 0/0 Vendor should have at least 02 Service Technicians & 02 Service Engineer having 5 years' experience on installation & commissioning of such projects (At least 3 projects). Provided CV of technicians and engineers as per above question. 0/0 1.3.11 Technical Manpower Resources 1.3.12 Technical Manpower Resources 1.3.13 Technical Manpower Resources 1.3.14 PPEs 1.3.15 Transportation 1.3.16 QHSE Policies Technical Resource has relevant experience in SIEMENS PLC or AB PLC. 0/0 CV must reflect same with year of completion of project along with project narrative. General Automation experience is Not Acceptable. Submitted CV of PLC engineer is confirmed employee of Bidder. 0/0 DCS Engineer has 5 year experience in DELTAV DCS. 0/0 Only DeltaV experience is required. Irrelevant Experience (e.g. ABB, Honeywell, Yokogawa etc.) is not required. Bidder will arrange and provide all necessary PPEs (Helmet,Coveralls, Safety Shoes etc) to their staff? Bidder to arrange their own transport for at-site movement and materials handling. Contrator staff must be well-versed with HSE policies and aware of Oil & Gas Plant hazards. All deputed staff must follow & comply with PPL HSE policy. 0/0 0/0 0/0 TECHNICAL ENVELOPE: 1.4 FINANCIAL STATUS OF THE FIRM WITH SUPPORTING DOCUMENTS - SECTION MAX SCORE = 100 Question Description 1.4.1 1 1.4.2 1 1.4.3 2 1.4.4 2 Complete set of Financial Statements for last 5 years including notes to the accounts (Mandatory Requirement for all 5 years) Provide evidence of above Firm’s average turnover during last 5 years Provide evidence of above Min/Max Score 0/50 Response 0/0 15/50 0/0 TECHNICAL ENVELOPE - ATTACHMENTS No Attachments Commercial Envelope 2.1 Total Material Value with Surcharges ( Items 2 ) 2.2 CONFIRM FOLLOWING AS PROVIDED IN THE BID ( Questions: 7 ) 2.3 List of Materials ( Items 1 , Columns: 2 ) 2.4 General Attachments COMMERCIAL ENVELOPE: 2.1 TOTAL MATERIAL VALUE WITH SURCHARGES Unit of Measurement 2.1.1 FOB /Packing Charges LUMP SUM (If any) 2.1.2 Freight (if any) LUMP SUM Section Sub Total Code Description Quantity 1 Unit Price (Exclusive Minimum Unit Maximum Unit Price Comments Taxes) Price Price 0 1 0 0 COMMERCIAL ENVELOPE: 2.2 CONFIRM FOLLOWING AS PROVIDED IN THE BID 2.2.1 2.2.2 2.2.3 2.2.4 2.2.5 2.2.6 2.2.7 Question Delivery Period Bid Validity Delivery Terms Country of Origin Port of Shipment Payment Terms Bid Bond Description Delivery Period Bid Validity (180 days) Delivery Terms Country of Origin Port of Shipment Payment Terms [LC / Advance / Net 30 days] Attach Scan Copy of Bid Bond (Priced) Response COMMERCIAL ENVELOPE: 2.3 LIST OF MATERIALS Code 2.3.1 0010179693-99-00010 Description SCADA System for 02 No Wells. Adhi South S5 & Adhi South S7 ****************************** * REMOTE TERMINAL UNIT (RTU) - QTY 02 Nos. ****************************** *********** Complete RTU to be supplied, installed, configured & commissioned at 02 Well Sites, and hooked up with existing SCADA MTU HMI at Control Room, on turnkey basis. This specification / scope of works of this project covers the study of the existing SCADA System, all related system engineering works, supply of materials, installation & C Unit Price Minimum Unit of Maximum Quantity (Exclusive Unit Price Comments Measurement Unit Price Taxes) Price AU 2 0 Section Sub Total Code 2.3.1 0010179693-99-00010 0 Description SCADA System for 02 No Wells. Adhi South S5 & Adhi South S7 ******************************* REMOTE TERMINAL UNIT (RTU) - QTY 02 Nos. ***************************************** Complete RTU to be supplied, installed, configured & commissioned at 02 Well Sites, and hooked up with existing SCADA MTU HMI at Control Room, on turnkey basis. This specification / scope of works of this project covers the study of the existing SCADA System, all related system engineering works, supply of materials, installation & C Currency: USD Total Price (excluding optional sections) 0 COMMERCIAL ENVELOPE - ATTACHMENTS No Attachments Sales / Total Services (Inclusive Tax % Sales Tax) ---