This document is the property of L&T Construction - PT&D -Renewable Business and must not be passed on to any third person or firm not authorised by us, nor be copied/made use of in full or part by such person or firm without our prior permission in writing. L&T 16.02.2022 A5 00 Issued for Approval Revision No. Purpose DES Electro Mech MS/SMK SVG 10-Feb-22 14-Feb-22 15-Feb-22 Prepared by Checked by Approved by Revision History Project: DESIGN, ENGINEERING, SUPPLY & PROCUREMENT, CONSTRUCTION, OPERATION AND MAINTENANCE OF 40 MW SOLAR PHOTOVOLTAIC GRID CONNECTED POWER PLANT AT HARIPAR, GUJARAT Engineering: L&T Construction - EDRC Renewables BU Owner: EPC Contractor: L&T Job Code: O20268-PTD-S Document Title : Power & Control cable schedule & Termination schedule Rev. No. L&T Doc.No. O 2 0 2 6 8 - P T D - S - S Y - C S - 0 5 1 1 00 Released For: PRELIMINARY ENQUIRY INFORMATION PAGE 1 OF 15 Size APPROVAL A4/A3 Page No. 1 of 13 FABRICATION Date Revision 14-Feb-22 R0 Contract No. Prepared By Client CONTROL CABLE SCHEDULE FOR 66kV LINE CUM TRANSFORMER FEEDER - (BAY NO- 601) O20268-PTD-S DEMPL Checked By BARVIN Project Approved By SIVA Doc. No. M/s. GSECL GSECL 40MW SOLAR POWER PLANT O20268-PTD-S-SY-TS-0511 R0 TOTAL NO. OF SHEETS REFERENCE DRAWINGS: SR. 1 DESCRIPTION Single Line Diagram (SLD) - 66KV Switchyard SR. DRAWING NO. 8 O20268-PTD-S-SY-VD-0516 2 66kV circuit breaker GTP, GA drawings O20268-PTD-S-SY-VD-0519 3 66kV Isolator with & without Earth Switch GTP & GA drawings O20268-PTD-S-SY-VD-0520 4 66kV CT GTP, GA drawings & TTR O20268-PTD-S-SY-VD-0521 5 6 7 66kV CVT/PT GTP, GA drawings & TTR 66/11kV AIS at Haripar – CT JB, PT JB & BMK 66kV Switchyard Control & Relay Panel Incomer & Transformer Bay C/P 6 01 X/Y/Z DESCRIPTION 66/11kV 40MVA (ONAN)Transformer GA & RTCC Control Schematics HT Panel Datasheet, General arrangement, 9 Schematic & Type Test Report LT Distribution Single line diagram(for Main Control 10 Room) LT Panel Datasheet & General Arrangement(ACDB, 11 DCDB) Nitrogen Injection Fire Prevention System for 66/11kV 12 40MVA (ONAN)Transformer DRAWING NO. O20268-PTD-S-SY-1L-0501 O20268-PTD-S-SY-VD-0522 001 O20268-PTD-S-SY-VD-0536 13 Tariff metering panel & their PT & CT schematic O20268-PTD-S-SY-VD-0525 14 A Outdoor Lighting Panel Drawings, Outdoor Lighting Layout and calculations O20268-PTD-S-AC-VD-0120A O20268-PTD-S-AC-1L-0102 O20268-PTD-S -AC-VD-0123 O20268-PTD-S-SY-VD-0518 O20268-PTD-S-SY-VD-0527 O20268-PTD-S-SY-VD-0529, O20268-PTD-S-SY-lt-0507 THIS FIELD IS OPTIONAL AND WILL BE ALPHABET A , B, C … BASED ON THE CABLE USED AS PARALLEL RUN CABLE SL. NO. STARTING FROM 001 AND INCREMENT SUBSEQUENTLY NOTE: 1. Actual Cable Lengths to be measured at site before cable cutting. THIS FIELD WILL BE SELECTED ON FOLLOWING CONDITIONS: X FOR CABLES WITHIN SWYD. Y FOR CABLES FROM SWYD. TO CONTROL ROOM Z FOR CABLES WITHIN CONTROL ROOM A AC/DC POWER CABLE FOR AUX. SYSTEM BAY NUMBER SYSTEM VOLTAGE C/P C P CONTROL CABLE POWER CABLE Cover Sheet Cables with in SWYD Cables with in Control Room Cables from SWYD to Control Room Date Revision 14-02-22 R0 CONTROL CABLE SCHEDULE FOR 66kV LINE CUM TRANSFORMER FEEDER - (BAY NO- 601) CABLES WITH IN SWITCHYARD CABLE NO. C C C C 6 6 6 6 01 01 01 01 X X X X 001 002 003 004 FROM 601-CT CORE: 1, 2 & 3 (R - PHASE) 601-CT CORE: 1, 2 & 3 (Y - PHASE) 601-CT CORE: 1, 2 & 3 (B - PHASE) 601-2N1 CT EQUIPMENT DESIGNATION TO 601-CT JB * *(SPARE TERMINALS: TB1-4, TB8, TB-12 T0 TB-20) SIZE 12CX2.5 601-CT JB * 12CX2.5 *(SPARE TERMINALS: TB1-4,8,13,17) 601-CT JB * 12CX2.5 *(SPARE TERMINALS: TB1-4,8,13,17) 601-2N1 CT MB 3CX2.5 LENGTH MTRS. 15 15 15 10 CORE: 1 C 6 01 X 005 601-2N2 CT 601-2N2 CT MB 3CX2.5 10 CORE: 2 C 6 01 X 006 601-PT CORE-1 & 2 (R-PHASE) 601-PT JB 5CX2.5 15 Prepared By DEMPL Checked By Approved By O20268-PTD-S Contract No. Client M/s. GSECL BARVIN Project GSECL 40MW SOLAR POWER PLANT SIVA Doc. No. O20268-PTD-S-SY-TS-0511 INTERCONNECTION DETAILS APPLICATION FERRULE TO FERRULE R-1S1 R-1S1 TB1-1 R-1S2 R-1S2 METERING CKT TB1-2 R-1S3 R-1S3 TB1-3 R-2S1 R-2S1 TB1-5 R-2S2 R-2S2 BACKUP PROTECTION CKT TB1-6 R-2S3 R-2S3 TB1-7 R-3S1 R-3S1 TB1-9 R-3S2 R-3S2 HV SIDE DIFFERENTIAL PROTN CKT TB1-10 R-3S3 R-3S3 TB1-11 CORE 1 2 3 4 5 6 7 8 9 10 to 12 FROM 1S1 1S2 1S3 2S1 2S2 2S3 3S1 3S2 3S3 SPARE 1 2 3 4 5 6 7 8 9 10 to 12 1S1 1S2 1S3 2S1 2S2 2S3 3S1 3S2 3S3 SPARE Y-1S1 Y-1S2 Y-1S3 Y-2S1 Y-2S2 Y-2S3 Y-3S1 Y-3S2 Y-3S3 TB2-1 TB2-2 TB2-3 TB2-5 TB2-6 TB2-7 TB2-9 TB2-10 TB2-11 Y-1S1 Y-1S2 Y-1S3 Y-2S1 Y-2S2 Y-2S3 Y-3S1 Y-3S2 Y-3S3 1 2 3 4 5 6 7 8 9 10 to 12 1S1 1S2 1S3 2S1 2S2 2S3 3S1 3S2 3S3 SPARE B-1S1 B-1S2 B-1S3 B-2S1 B-2S2 B-2S3 B-3S1 B-3S2 B-3S3 TB3-1 TB3-2 TB3-3 TB3-5 TB3-6 TB3-7 TB3-9 TB3-10 TB3-11 B-1S1 B-1S2 B-1S3 B-2S1 B-2S2 B-2S3 B-3S1 B-3S2 B-3S3 1 S1 2N1-S1 TB1-39 2N1S1 2 S2 2N1-S2 TB1-40 2N1S2 3 SPARE 1 S1 2N2-S1 TB1-41 2N2S1 2 S2 2N2-S2 TB1-42 2N2S2 3 SPARE 1 2 3 4 5 1a 1n 2a 2n SPARE - TB1-1 TB1-2 TB1-3 TB1-4 E111 E131 E151 E171 R0 REFERENCE DRAWING DETAILS DRG. NO. / SHEET NO. O20268-PTD-S-SY-VD-0525_REV.02 (14 21102-6B SH 01 OF 16); O20268-PTD-S-SY-VD-0521 (4IT/SN/2011/B,REV.03); O20268-PTD-S-SY-VD-0536 (HTS/01/2019-20 SH 04 OF 04) METERING CKT BACKUP PROTECTION CKT O20268-PTD-S-SY-VD-0525_REV.02 (14 21102-6B SH 01 OF 16); O20268-PTD-S-SY-VD-0521 (4IT/SN/2011/B,REV.03); O20268-PTD-S-SY-VD-0536 (HTS/01/2019-20 SH 04 OF 04) HV SIDE DIFFERENTIAL PROTN CKT METERING CKT BACKUP PROTECTION CKT O20268-PTD-S-SY-VD-0525_REV.02 (14 21102-6B SH 01 OF 16); O20268-PTD-S-SY-VD-0521 (4IT/SN/2011/B,REV.03); O20268-PTD-S-SY-VD-0536 (HTS/01/2019-20 SH 04 OF 04) HV SIDE DIFFERENTIAL PROTN CKT 87 RELAY FOR REF O20268-PTD-S-SY-VD-0525_REV.02 (14 21102-6B SH 01 , 04, OF 16); O20268-PTD-S-SY-VD-0516 67 RELAY FOR SEF O20268-PTD-S-SY-VD-0525_REV.02 (14 21102-6B SH 01 , 05,OF 16); O20268-PTD-S-SY-VD-0516 METERING PROTECTION O20268-PTD-S-SY-VD-0525_REV.02 (14 21102-6B SH 01 , 03, 05 OF 16); O20268-PTD-S-SY-VD-0522; O20268-PTD-S-SY-VD-0536 Date Revision 14-02-22 R0 CONTROL CABLE SCHEDULE FOR 66kV LINE CUM TRANSFORMER FEEDER - (BAY NO- 601) CABLES WITH IN SWITCHYARD CABLE NO. C C C C C C C C 6 6 6 6 6 6 6 6 01 01 01 01 01 01 01 01 X X X X X X X X FROM 007 008 009 010 011 012 013 014 EQUIPMENT DESIGNATION TO 601-PT CORE-1 & 2 (Y-PHASE) 601-PT JB 601-PT CORE-1 & 2 (B-PHASE) 601-PT JB 601-MPT (R-PHASE) ABT METERING PANEL 601-MPT (Y-PHASE) ABT METERING PANEL 601-MPT (B-PHASE) ABT METERING PANEL 601-MCT (R-PHASE) ABT METERING PANEL 601-MCT (Y-PHASE) ABT METERING PANEL 601-MCT (B-PHASE) ABT METERING PANEL SIZE LENGTH MTRS. 5CX2.5 15 5CX2.5 3CX2.5 3CX2.5 3CX2.5 3CX2.5 3CX2.5 3CX2.5 15 15 15 15 15 15 15 Prepared By DEMPL Checked By Approved By O20268-PTD-S Contract No. Client M/s. GSECL BARVIN Project GSECL 40MW SOLAR POWER PLANT SIVA Doc. No. O20268-PTD-S-SY-TS-0511 INTERCONNECTION DETAILS CORE FROM FERRULE TO FERRULE 1 2 3 4 5 1a 1n 2a 2n SPARE - TB1-7 TB1-8 TB1-9 TB1-10 E211 E231 E251 E271 1 2 3 4 5 1a 1n 2a 2n SPARE - TB1-13 TB1-14 TB1-15 TB1-16 E311 E331 E351 E371 1 2 3 1a 1n SPARE - - - 1 2 3 1a 1n SPARE - - 1 2 3 1a 1n SPARE - 1 2 3 1S1 1S2 SPARE 1 2 3 1S1 1S2 SPARE APPLICATION METERING PROTECTION METERING PROTECTION R0 REFERENCE DRAWING DETAILS DRG. NO. / SHEET NO. O20268-PTD-S-SY-VD-0525_REV.02 (14 21102-6B SH 01 , 03, 05 OF 16); O20268-PTD-S-SY-VD-0522; O20268-PTD-S-SY-VD-0536 O20268-PTD-S-SY-VD-0525_REV.02 (14 21102-6B SH 01 , 03, 05 OF 16); O20268-PTD-S-SY-VD-0522; O20268-PTD-S-SY-VD-0536 TARIFF METERING O20268-PTD-S-SY-VD-0527 REFER NOTE-1 - TARIFF METERING O20268-PTD-S-SY-VD-0527 REFER NOTE-1 - - TARIFF METERING O20268-PTD-S-SY-VD-0527 REFER NOTE-1 R-1S1 R-1S2 - - TARIFF METERING O20268-PTD-S-SY-VD-0527 REFER NOTE-1 Y-1S1 Y-1S2 - - TARIFF METERING O20268-PTD-S-SY-VD-0527 REFER NOTE-1 - TARIFF METERING O20268-PTD-S-SY-VD-0527 REFER NOTE-1 1S1 1 B-1S1 1S2 B-1S2 2 SPARE 3 NOTE -1: Cable shall be DES ELECTRO scope of work- Number of Core & sqmm will be confirm based on PGVCL requirement. Date Revision 14-Feb-22 R0 CONTROL CABLE SCHEDULE FOR 66kV LINE CUM TRANSFORMER FEEDER - (BAY NO- 601) CABLES FROM SWITCHYARD TO CONTROL ROOM EQUIPMENT DESIGNATION CABLE NO. C C C 6 6 6 01 01 01 Y Y Y 001 002 003 SIZE 5CX2.5 601-CT JB * 66kV LINE CONTROL & RELAY PANEL CORE-2 (R, Y, B -PHASE) *(SHORT TB1-6,TB2-6 & TB3-6 EARTHED IN 601 CT JB) 5CX2.5 601-CT JB * CORE-3 (R, Y, B -PHASE) MTRS. 55 55 C C 6 6 6 01 01 01 Y Y Y 004 004A 005 6 01 Y 006 C 6 6 01 01 Y Y 007 008 BARVIN Project SIVA Doc. No. GSECL 40MW SOLAR POWER PLANT O20268-PTD-S-SY-TS-0511 INTERCONNECTION DETAILS APPLICATION CORE 1 2 3 4 5 FROM TB1-1 TB2-1 TB3-1 TB3-2 SPARE Ferrule R-1S1 Y-1S1 B-1S1 B-1S2 TO X1:1 X1:2 X1:3 X1:4 Ferrule D11 D31 D51 D71 1 2 3 4 5 TB1-5 TB2-5 TB3-5 TB3-6 SPARE R-2S1 Y-2S1 B-2S1 B-2S2 X1:5 X1:6 X1:7 X1:8 C11 C31 C51 C71 R0 REFERENCE DRAWING DETAILS DRG. NO. / SHEET NO. METERING CKT O20268-PTD-S-SY-VD-0525_REV.02 (14 211026B SH 01 OF 16); O20268-PTD-S-SY-VD0521(4IT/SN/2011/B,REV.03); O20268-PTD-S-SY-VD-0536(HTS/01/2019-20 SH 04 OF 04) BACKUP PROTECTION CKT O20268-PTD-S-SY-VD-0525_REV.02 (14 211026B SH 01 OF 16); O20268-PTD-S-SY-VD0521(4IT/SN/2011/B,REV.03); O20268-PTD-S-SY-VD-0536(HTS/01/2019-20 SH 04 OF 04) 55 1 2 3 4 5 TB1-9 TB2-9 TB3-9 TB3-10 SPARE R-3S1 Y-3S1 B-3S1 B-3S2 X1:9 X1:10 X1:11 X1:12 A11 A31 A51 A71 601-NCT MB CORE-1 66kV LINE CONTROL & RELAY PANEL 3CX2.5 60 1 2 3 TB1-39 TB1-40 SPARE 2N1S1 2N1S2 X1:17 X1:18 A181 A111 NCT SIDE REF PROTN CKT O20268-PTD-S-SY-VD-0525_REV.02 (14 211026B SH 01 , 04, 05,OF 16); O20268-PTD-S-SY-VD0516 601-NCT MB CORE-2 66kV LINE CONTROL & RELAY PANEL 1 2 3 TB1-41 TB1-42 SPARE 2N2S1 2N2S2 X1:19 X1:20 A281 A211 NCT SIDE SEF PROTN CKT O20268-PTD-S-SY-VD-0525_REV.02 (14 211026B SH 01 , 04, 05,OF 16); O20268-PTD-S-SY-VD0516 601-PT JB* CORE-1 (R, Y, B, N -PHASE) 66kV LINE CONTROL & RELAY PANEL 1 2 3 4 5 TB2-1 TB2-5 TB2-9 TB2-10 SPARE E112 E212 E312 E332 XB:1 XB:2 XB:3 XB:4 E11 E31 E51 E71 METERING O20268-PTD-S-SY-VD-0525_REV.02 (14 211026B SH 01 OF 16); O20268-PTD-S-SY-VD-0522; O20268-PTD-S-SY-VD-0536 1 2 3 4 5 TB2-3 TB2-7 TB2-11 TB2-12 SPARE E152 E252 E352 E372 XB:5 XB:6 XB:7 XB:8 E21 E41 E61 E81 PROTECTION O20268-PTD-S-SY-VD-0525_REV.02 (14 211026B SH 01 OF 16); O20268-PTD-S-SY-VD-0522; O20268-PTD-S-SY-VD-0536 1 2 3 4 5 6 7 8 9 10 11 TO 19 TB4-2 TB4-1 TB3-2 TB3-1 TB4-3 TB4-4 TB3-4 TB3-3 TB2-1 TB2-2 SPARE CM2 CM1 OM2 OM1 CM3 CM4 OM4 OM3 K1 K2 X9-23 X9-24 X9-25 X9-26 X5-8 X5-9 X5-8 X5-10 X4-52 X4-53 K501 K539 K501 K541 L1 L11 L1 L13 K301 K302 1 2 3 4 5 6 7 8 9 TO 10 SPARE A1 1 B1 1 A2 2 B2 2 X9-27 X9-28 X9-29 X9-30 X5-19 X5-20 X5-19 X5-21 K501 K543 K501 K545 L1 L35 L1 L37 3CX2.5 5CX2.5 60 60 601-PT JB* CORE-2 (R, Y, B, N -PHASE) 66kV LINE CONTROL & RELAY PANEL 5CX2.5 60 *(SHORT TB2-4,TB2-8, TB2-12 NEUTRAL IN TB212 OF 601-PT JB) C Checked By Approved By 5CX2.5 *(SHORT TB2-2,TB2-6, TB2-10 NEUTRAL IN TB210 OF 601-PT JB) C M/s. GSECL 66kV LINE CONTROL & RELAY PANEL *(SHORT TB1-6,TB2-6 & TB3-6 EARTHED IN 601 CT JB) C DEMPL client LENGTH FROM TO 601-CT JB * 66kV LINE CONTROL & RELAY PANEL CORE-1 (R, Y, B -PHASE) *(SHORT TB1-2,TB2-2 & TB3-2 EARTHED IN 601 CT JB) O20268-PTD-S Contract No. Prepared By 601-89A ISOLATOR 601-89ES ISOLATOR (EARTH SWITCH) 66kV LINE CONTROL & RELAY PANEL 66kV LINE CONTROL & RELAY PANEL 19CX2.5 10CX2.5 60 60 O20268-PTD-S-SY-VD-0525_REV.02 (14 211026B SH 01 OF 16); O20268-PTD-S-SY-VDHV SIDE DIFFERENTIAL PROTN CKT 0521(4IT/SN/2011/B,REV.03); O20268-PTD-S-SY-VD-0536(HTS/01/2019-20 SH 04 OF 04) 89A OPEN 89A CLOSE 89A ISOLATOR SEMAPHORE 89A ISOLATOR SEMAPHORE O20268-PTD-S-SY-VD-0525_REV.02 (14 211026B SH 01 , 03, 05,15 OF 16); O20268-PTD-S-SY-VD-0520 FOR ISO.IL SH.2 OF 16 (DC SUPPLY) 89ES OPEN 89ES CLOSE 89ES EARTH SWITCH SEMAPHORE 89ES EARTH SWITCH SEMAPHORE O20268-PTD-S-SY-VD-0525_REV.02 (14 211026B SH 01 , 03, 05,15 OF 16); O20268-PTD-S-SY-VD-0520 (Manual lever type Op Mechanism for earth switch) Date Revision 14-Feb-22 R0 CONTROL CABLE SCHEDULE FOR 66kV LINE CUM TRANSFORMER FEEDER - (BAY NO- 601) CABLES FROM SWITCHYARD TO CONTROL ROOM EQUIPMENT DESIGNATION CABLE NO. FROM C C 6 6 01 01 Y Y 009 010 601-89B ISOLATOR 66kV LINE CONTROL & RELAY PANEL POWER TRAFO. MB 66kV LINE CONTROL & RELAY PANEL *LOOP TB1-5, TB1-3, TB1-15, TB1-13, & TB1-25 IN TB1-23 OF MB FOR TRAFO. TROUBLE CKT_GROUP-1 Checked By BARVIN Project Approved By SIVA Doc. No. 01 Y 011 POWER TRANSFORMER MB INTERCONNECTION DETAILS APPLICATION CORE FROM Ferrule TO Ferrule 19CX2.5 50 1 2 3 4 5 6 7 8 9 10 11 TO 19 TB4-2 TB4-1 TB3-2 TB3-1 TB4-3 TB4-4 TB3-4 TB3-3 TB2-1 TB2-2 SPARE CM2 CM1 OM2 OM1 CM3 CM4 OM4 OM3 K1 K2 X9-31 X9-32 X9-33 X9-34 X5-8 X5-9 X5-8 X5-10 X4-52 X4-53 K501 K543 K501 K545 L1 L11 L1 L13 K301 K302 9 10 11 12 13 14 15 16 17 TO 19 TB1-5 TB1-3 TB1-15 TB1-13 TB1-25 TB1-23 TB1-6 TB1-4 TB1-16 TB1-14 TB1-26 TB1-24 TB1-9 TB1-7 TB1-33 TB1-37 TB1-10 TB1-8 TB1-34 TB1-38 TB1-35 TB1-36 TB1-1 TB1-2 SPARE K3 L1 K7 L5 K9 L7 K4 L2 K8 L6 K10 L8 K5 L3 K11 L9 K6 L4 K12 L10 K13 K14 K1 K2 1 2 3 4 5 6 7 TB1-11 TB1-12 TB1-21 TB1-22 TB1-31 TB1-32 SPARE OM2 OM1 1V1RW2 1V1RW1 2V1RW2 2V1RW1 19CX2.5 60 1 8 RTCC PANEL GSECL 40MW SOLAR POWER PLANT O20268-PTD-S-SY-TS-0511 MTRS. *LOOP TB1-9, TB1-7, TB1-33, TB1-37, OF MB FOR TRAFO. TROUBLE CKT_GROUP-2 6 M/s. GSECL SIZE 2 3 4 5 6 7 C DEMPL client LENGTH TO O20268-PTD-S Contract No. Prepared By 7CX2.5 60 R0 REFERENCE DRAWING DETAILS DRG. NO. / SHEET NO. 89B OPEN 89B CLOSE 89B ISOLATOR SEMAPHORE 89B ISOLATOR SEMAPHORE O20268-PTD-S-SY-VD-0525_REV.02 (14 211026B SH 01 , 03, 05 OF 16); O20268-PTD-S-SY-VD-0520 FOR ISO.IL SH.2 OF 16 X4:1 K201 X4:2 X4:3 X4:4 X4:5 X4:6 X4:7 K221 K223 K225 K227 K229 K231 X4:8 K401 X4:9 X4:10 X4:11 X4:12 X9:3 X9:4 X9:1 X9:2 K427 K429 K431 K433 K501 K519 K501 K517 BUCHH. TRIP BUCH. ALARM HV WTI TRIP HV WTI ALARM LV WTI TRIP LV WTI ALARM BUCHH. TRIP BUCH. ALARM HV WTI TRIP HV WTI ALARM LV WTI TRIP LV WTI ALARM OTI TRIP OTI ALARM MAIN TANK PRV TRIP MOG ALARM OTI TRIP OTI ALARM MAIN TANK PRV TRIP MOG ALARM OLTC PRV TRIP OLTC PRV TRIP OSR TRIP OSR TRIP TB2-17 TB2-18 TB2-19 TB2-20 TB2-21 TB2-22 OM2 OM1 1V1RW2 1V1RW1 2V1RW2 2V1RW1 FOR ROTI REPEATER FOR ROTI REPEATER FOR RWTI REPEATER FOR RWTI REPEATER FOR RWTI REPEATER FOR RWTI REPEATER O20268-PTD-S-SY-VD-0525_REV.02 (14 211026B SH 07 OF 16); O20268-PTD-S-SY-VD-0516 / O20268-PTD-S-SY-VD-0525_REV.02 (14 211026B SH 08 OF 16) Terminal X4:42 and X4:43 of Master trip circuit to be wired (connected) to spare contact of of 30X1 relay (Refer Sheet 10 of 16) O20268-PTD-S-SY-VD-0516 Date Revision 14-Feb-22 R0 CONTROL CABLE SCHEDULE FOR 66kV LINE CUM TRANSFORMER FEEDER - (BAY NO- 601) CABLES FROM SWITCHYARD TO CONTROL ROOM EQUIPMENT DESIGNATION CABLE NO. C 6 C 01 6 01 Y 012 Y 013 O20268-PTD-S Contract No. Prepared By DEMPL M/s. GSECL client Checked By BARVIN Project Approved By SIVA Doc. No. GSECL 40MW SOLAR POWER PLANT O20268-PTD-S-SY-TS-0511 INTERCONNECTION DETAILS LENGTH APPLICATION R0 REFERENCE DRAWING DETAILS FROM TO SIZE MTRS. CORE FROM Ferrule TO Ferrule OLTC PANEL RTCC PANEL 27CX2.5 60 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 TO 27 TB1-1 TB1-2 TB1-3 TB1-4 TB1-5 TB1-6 TB1-7 TB1-8 TB1-9 TB1-10 TB1-11 TB1-12 TB1-13 TB1-14 TB1-15 TB1-16 TB1-17 TB1-18 TB1-19 TB1-20 TB1-21 TB1-22 TB1-23 TB1-24 SPARE N150 N151 N152 N219 N220 N221 N222 N223 N224 N225 N96 N97 N118 NO 117 N117 N119 N120 N106 N107 N113 N102 N126 N98 N114 TB1-1 TB1-2 TB1-3 TB1-4 TB1-5 TB1-6 TB1-7 TB1-8 TB1-9 TB1-10 TB1-11 TB1-12 TB1-13 TB1-14 TB1-15 TB1-16 TB1-17 TB1-18 TB1-19 TB1-20 TB1-21 TB1-22 TB1-23 TB1-24 - OLTC OPERATION CABLE BETWEEN OLTC TO RTCC O20268-PTD-S-SY-VD-0516_PAGE 22 OF 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 TO 27 TB1-37 TB1-38 TB1-39 TB1-40 TB1-41 TB1-42 TB1-43 TB1-44 TB1-45 TB1-46 TB1-47 TB1-48 TB1-49 TB1-50 TB1-51 TB1-52 TB1-53 TB1-54 TB1-55 TB1-56 TB1-57 TB1-58 TB1-59 TB1-60 SPARE N303 N304 N305 N306 N307 N308 N309 N310 N311 N312 N313 N314 N315 N316 N317 N318 N319 N320 H335 N36 N105 N126 NO 223 NO 224 TB1-37 TB1-38 TB1-39 TB1-40 TB1-41 TB1-42 TB1-43 TB1-44 TB1-45 TB1-46 TB1-47 TB1-48 TB1-49 TB1-50 TB1-51 TB1-52 TB1-53 TB1-54 TB1-55 TB1-56 TB1-57 TB1-58 TB1-59 TB1-60 - OLTC OPERATION CABLE BETWEEN OLTC TO RTCC OLTC PANEL RTCC PANEL 27CX2.5 60 DRG. NO. / SHEET NO. O20268-PTD-S-SY-VD-0516_PAGE 22 OF 25 Date Revision 14-Feb-22 R0 CONTROL CABLE SCHEDULE FOR 66kV LINE CUM TRANSFORMER FEEDER - (BAY NO- 601) CABLES FROM SWITCHYARD TO CONTROL ROOM EQUIPMENT DESIGNATION CABLE NO. C 6 C C 01 6 6 C 01 01 6 Y 01 014 Y Y 015 016 Y 017 FROM OLTC PANEL RTCC PANEL TO RTCC PANEL 66kV LINE CONTROL & RELAY PANEL 601-52CB (66kV SF6 CIRCUIT BREAKER) 66kV LINE CONTROL & RELAY PANEL 601-52CB (66kV SF6 CIRCUIT BREAKER) 66kV LINE CONTROL & RELAY PANEL 19CX2.5 10CX2.5 10CX2.5 MTRS. 60 DEMPL M/s. GSECL client Checked By BARVIN Project Approved By SIVA Doc. No. GSECL 40MW SOLAR POWER PLANT O20268-PTD-S-SY-TS-0511 INTERCONNECTION DETAILS LENGTH SIZE 10CX2.5 O20268-PTD-S Contract No. Prepared By APPLICATION R0 REFERENCE DRAWING DETAILS CORE 1 2 3 4 5 6 7 TO 10 FROM TB1-61 TB1-62 TB1-63 TB1-64 TB1-65 TB1-66 SPARE Ferrule X3 X4 X50 X51 X52 X53 TO TB1-61 TB1-62 TB1-63 TB1-64 TB1-65 TB1-66 Ferrule - 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 TO 19 TB3-6 TB3-5 TB3-6 TB3-7 TB1-37 TB1-38 TB1-40 TB1-46 TB1-48 TB1-50 TB1-52 TB1-53 TB1-54 TB3-25 TB3-26 SPARE N148 N423 N148 N424 N303 N304 N306 N312 N314 N316 N318 N319 N320 L35 L36 X10-1 X10-2 X10-3 X10-4 X9-7 X9-8 X9-8 X9-10 X9-12 X9-6 X9-16 X9-18 X9-20 TB-TB-- - 60 1 2 3 4 5 6 7 8 9 TO 10 X1:1 X1:2 X1:59 X1:9 X1:60 X1:10 X1:12 X1:13 SPARE +VE -VE K1+ K11 K1+ K21 K22 K26 X4-13 X4-14 X4-15 X4-16 X4-15 X4-17 X4-18 X4-19 K1 K2 K3 K11 K3 K13 K17 K19 DC SUPPLY-1 BKR TRIPPING-1 CKT SH.6 OF 16 REMOTE CLOSE O20268-PTD-S-SY-VD-0525_REV.02 (14 21102REMOTE CLOSE 6B) (CRP : SH 06 OF 16); O20268-PTD-S-SY-VDREMOTE TRIP CKT-1 0519 CIRCUIT BREAKER (SHEET 2 OF 8) REMOTE TRIP CKT-1 PROT. & POST CLOSE TRIP CIRCUITPRE CLOSE TRIP CIRCUIT-I 60 1 2 3 4 X1:3 X1:4 X1:61 X1:11 +VE -VE K3+ K31 X4-24 X4-25 X4-26 X4-27 K101 K102 K103 K105 X1:14 K32 X4-28 K109 X1:15 K36 X4-29 K111 X3:101 X3:102 SPARE U21 U22 X4-58 X4-59 K401 K417 DC SUPPLY-2 BKR TRIPPING-2 CKT SH.6 OF 16 REMOTE TRIP CKT2 REMOTE TRIP CKT2 PROT. & POST CLOSE TRIP CIRCUITII SUPERVISION PRE CLOSE TRIP CIRCUIT-II SUPERVISION TO DIFF, RELAY HV CB OPEN SH. 4 OF 16 10 5 6 7 8 9 TO 10 DRG. NO. / SHEET NO. OLTC OPERATION CABLE BETWEEN OLTC TO RTCC TAP CHANGER - COMMON TAP RISER COMMAND TAP CHANGER - COMMON TAP LOWER COMMAND OLTC-COMMON OLTC - MOTOR TRIP CONTACT CONTROL SUPPLY FAIL UPPER LIMIT REACHED LOWER LIMIT REACHED TAP POISITION INCOMPLETE SWITCH - AUTO SWITCH - LOCAL SWITCH - REMOTE TPI - 4-20 Ma O20268-PTD-S-SY-VD-0516_PAGE 22 OF 25 O20268-PTD-S-SY-VD-0525_REV.02 /O20268PTD-S-SY-VD-0516 O20268-PTD-S-SY-VD-0525_REV.02 (14 211026B) (CRP : SH 04, 06 OF 16); O20268-PTD-S-SYVD-0519 CIRCUIT BREAKER (SHEET 02, 03 OF 8) Date Revision 14-Feb-22 R0 CONTROL CABLE SCHEDULE FOR 66kV LINE CUM TRANSFORMER FEEDER - (BAY NO- 601) CABLES FROM SWITCHYARD TO CONTROL ROOM EQUIPMENT DESIGNATION CABLE NO. FROM C C C 6 6 6 01 01 01 Y Y Y 018 019 020 601-52CB (66kV SF6 CIRCUIT BREAKER) 601-52CB (66kV SF6 CIRCUIT BREAKER) 601-52CB (66kV SF6 CIRCUIT BREAKER) 66kV LINE CONTROL & RELAY PANEL 66kV LINE CONTROL & RELAY PANEL 66kV LINE CONTROL & RELAY PANEL DEMPL M/s. GSECL client Checked By BARVIN Project Approved By SIVA Doc. No. GSECL 40MW SOLAR POWER PLANT O20268-PTD-S-SY-TS-0511 INTERCONNECTION DETAILS LENGTH TO O20268-PTD-S Contract No. Prepared By APPLICATION SIZE MTRS. CORE FROM Ferrule TO Ferrule 19CX2.5 60 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 TO 19 X1:109 X1:110 X1:103 X1:104 X1:65 X1:66 X1:69 X1:70 X1:55 X1:56 X1:39 X1:40 X1:34 X1:35 X1:28 X1:29 SPARE U41 U42 U23 U24 L11 L12 L26 L27 L15 L16 L17 L18 L9 L10 L5 L6 X9-35 X9-36 X9-37 X9-38 X9-39 X9-40 X9-41 X9-42 X9-47 X9-48 X9-49 X9-50 X9-51 X9-52 X9-53 X9-54 K501 K551 K501 K553 K501 K555 K501 K557 K501 K567 K501 K569 K501 K571 K501 K573 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 TO 19 X1:81 X1:82 X1:111 X1:112 X1:113 X1:114 X1:53 X1:54 X1:22 X1:23 X1:117 X1:118 X1:115 X1:116 X1:121 X1:122 SPARE L23 L25 U43 U44 U51 U52 L29 L30 L1 L2 U61 U62 U53 U54 U71 U72 X9-55 X9-56 X5-1 X5-2 X5-1 X5-3 X5-4 X5-5 X5-6 X5-7 X5-11 X5-12 X5-11 X5-13 X5-14 X5-15 K501 K575 L1 L3 L1 L5 L1 L7 L1 L9 L1 L15 L1 L17 L19 L21 1 2 3 4 5 TO 10 X3:105 X3:106 X1:32 X1:33 SPARE U31 U32 L7 L8 X4-64 X4-65 X6-3 X6-4 K201 K211 L103 L127 19CX2.5 10CX2.5 R0 REFERENCE DRAWING DETAILS DRG. NO. / SHEET NO. 52 CB OPEN 52 CB CLOSE CB FIELD LOCAL MODE SELECTION FROM FIELD PANEL CB-REMOTE END ENABLED FROM O20268-PTD-S-SY-VD-0525_REV.02 (14 21102FIELD 6B) (CRP : SH 12 , 14 OF 16); O20268-PTD-S-SYVD-0519 CIRCUIT BREAKER (SHEET 3, 4 OF 8) SPRING DISCHARGE CB CONTROL SUPPLY FAIL CB SF6 GAS FLOW PRESSURE ALARM CB SF6 GAS FLOW PRESSURE LOCKOUT 60 60 CB MOTOR SUPPLY FAIL CB CLOSE INDICATION CB OPEN INDICATION SPRING CHARGED INDICATION SF6 GAS PRESSURE NORMAL INDICATION O20268-PTD-S-SY-VD-0525_REV.02 (14 211026B) (CRP : SH 14, 15 OF 16); O20268-PTD-S-SYVD-0519 CIRCUIT BREAKER (SHEET 3,4 OF 8)/ 52 CB SEMAPHORE INDICATION AUTO TRIP TO 67 RELAY I/P CB OPEN SH. 5 OF 16 SF6 GAS PRESSURE LOW O20268-PTD-S-SY-VD-0525_REV.02 (14 211026B) (CRP : SH 05, 16 OF 16); O20268-PTD-S-SYVD-0519 CIRCUIT BREAKER (SHEET 3, 4 OF 8) Date 14-02-2022 Revision R0 CONTROL CABLE SCHEDULE FOR 66kV LINE CUM TRANSFORMER FEEDER - (BAY NO- 601) CABLES WITH IN CONTROL ROOM CABLE NO. C C 6 6 01 01 Z Z 001 002 FROM POWER TRANSFORMER NIPFS CONTROL PANEL EQUIPMENT DESIGNATION TO 66kV LINE CONTROL & RELAY PANEL 11kV HT PANEL- (OUTGOING TO POWER 66kV LINE CONTROL & RELAY PANEL TRAFO) 6 01 Z 003 601-LV CT MB * CORE-3 (R, Y, B -PHASE) *(SHORT X2-237, 238,239,240 AND EARTHED IN 601-LV CT AT HT PANEL) 66kV LINE CONTROL & RELAY PANEL DEMPL Checked By Approved By Client M/s. GSECL BARVIN Project GSECL 40MW SOLAR POWER PLANT SIVA Doc. No. INTERCONNECTION DETAILS FROM Ferrule O20268-PTD-S-SY-TS-0511 SIZE LENGTH MTRS. CORE TO Ferrule 19CX2.5 15 1 X4:1 1 X4-40 K201 2 3 4 5 6 7 8 9 10 11 12 13 TO 19 X4:2 X2:1 X2:7 X2:1 X2:14 X2:1 X2:15 X2:1 X2:18 X2:1 X2:17 SPARE 2 1 7' 1 14' 1 15' 1 18' 1 17' X4-41 X4-54 X4-55 X7-1 X7-2 X7-15 X7-16 X7-23 X7-24 X7-25 X7-26 K237 K401 K411 U1 U2 U15 U16 U23 U24 U25 U26 1 X5:37 U37 X4-36 K201 2 X5:38 U38 X4-37 K237 3 X5:25 U25 X4-44 K201 4 X5:26 U26 X4-45 K237 5 X5:45 K3 X4-48 K243 6 X5:46 K18 X4-49 K245 7 X5:1 K9 X4-50 K247 8 X5:2 K9A X4-51 K249 9 X5:39 U39 X4-60 K401 10 X5:40 U40 X4-61 K419 11 X5:47 K3 X4-68 K251 12 X5:48 K18 X4-69 K253 13 14 15 16 17 18 X4:32 X4:33 X4:34 X4:35 X4:30 X4:31 K3D K13 K103A K105 K3A K5 X7-35 X7-36 X7-37 X7-38 X7-39 X7-40 U35 U36 U37 U38 U39 U40 19 TB-- - X7-41 U41 20 TB-- - X4-20 K9 - X4-21 K9A C-112 C-132 C-152 C-170 X1:13 X1:14 X1:15 X1:16 A21 A41 A61 A81 27CX2.5 70 TO BE KEPT LOOPED AT CRP TB. SINCE NO RELATED TB AVAILABLE AT HT PANEL C O20268-PTD-S Contract No. Prepared By 5CX2.5 70 21 TB-- 22 TO 27 SPARE 1 2 3 4 5 X2:231 X2:233 X2:235 X2:237 SPARE APPLICATION R0 REFERENCE DRAWING DETAILS DRG. NO. / SHEET NO. TRIPPING FROM NIFPS SH.8 OF 16 DIFF, RELAY INPUT FOR NIFPS SH. 4 OF 16 86 RELAY O/P FOR NIFPS, SH.8 OF 16 DIFF. RELAY O/P FOR NIFPS SH. 4 OF 16 BUCHHOLZ TRIP FOR NIFPS SCHEME SH. 9 OF 16 MAIN PRV TRIP FOR NIFPS SCHEME SH. 9 OF 16 O20268-PTD-S-SY-VD-0525_REV.02 (14 21102-6B SH 04,8,9 OF 16); O20268-PTD-S -AC-VD-0123, NIFPS (SHEET 6 OF 8) O20268-PTD-S-SY-VD-0525_REV.02 (14 21102-6B) FROM 11kV LV SIDE TRIP RELAY I/P (CRP : SH 08 OF 16) ; O20268-PTD-S-AC-VD-0120A R2 MCR HT PANEL TO 86 SH.8 OF 16 (SHEET 23 OF 23A) O20268-PTD-S-SY-VD-0525_REV.02 (14 21102-6B) LV LBB TRIP OPTD./LV REAR DOOR (CRP : SH 08 OF 16) ; O20268-PTD-S-AC-VD-0120A R2 MCR HT PANEL OPEN SH.8 OF 16 3VS318602 (SHEET 21A OF 21B) 86 TO TRIP LV BKR SH.8 OF 16 O20268-PTD-S-SY-VD-0525_REV.02 (14 21102-6B) (CRP : SH 08 OF 16) ; O20268-PTD-S-AC-VD-0120A R2 MCR HT PANEL 3VS318602 (SHEET 23 OF 23A) TO 86 LV BKR CLOSING INTERLOCK SH.8 OF 16 O20268-PTD-S-SY-VD-0525_REV.02 (14 21102-6B) (CRP : SH 08 OF 16) ; O20268-PTD-S-AC-VD-0120A R2 MCR HT PANEL 3VS318602 (SHEET 22 OF 22A) TO DIFF, RELAY LV CB OPEN SH.4 OF 16 O20268-PTD-S-SY-VD-0525_REV.02 (14 21102-6B) (CRP : SH 04 OF 16) ; O20268-PTD-S-AC-VD-0120A R2 MCR HT PANEL 3VS318602 (SHEET 22B OF 22C) O20268-PTD-S-SY-VD-0525_REV.02 (14 21102-6B) LBB TRIP TO LV SIDE TRIP RELAY, (CRP : SH 05 OF 16) ; O20268-PTD-S-AC-VD-0120A R2 MCR HT PANEL SH 5 OF 16 3VS318602 (SHEET 23 OF 23A) CB OPEN COMMAND SPARE, SH.14.1 OF 16 CB CLOSE COMMAND SPARE, SH.14.1 OF 16 O20268-PTD-S-SY-VD-0525_REV.02 (14 21102-6B) (CRP : SH 06 OF 16) ; O20268-PTD-S-AC-VD-0120A R2 MCR HT PANEL 86(LV SIDE) T CLOSING SH 6 OF 16 (SHEET 01A OF 2) LV SIDE DIFFERENTIAL PROTN CKT O20268-PTD-S-SY-VD-0525_REV.02 (14 21102-6B SH 01, 04 OF 16); O20268-PTD-S-AC-VD-0120A R2 MCR HT PANEL 3VS318602 (SHEET 21B OF 21C) Date Revision 14-02-2022 R0 CONTROL CABLE SCHEDULE FOR 66kV LINE CUM TRANSFORMER FEEDER - (BAY NO- 601) AC/ DC POWER CABLE FOR AUXILIARY SYSTEM EQUIPMENT DESIGNATION TO 7 Power Receptacle O20268-PTD-S Contract No. Prepared By DEMPL Checked By BARVIN Project Approved By SIVA Doc. No. M/s. GSECL Client INTERCONNECTION DETAILS FROM FERRULE TO 11 12 13 R Y B N GSECL 40MW SOLAR POWER PLANT O20268-PTD-S-SY-TS-0511 R0 REFERENCE DRAWING DETAILS APPLICATION DRG. NO. / SHEET NO. FERRULE 14 15 17 415V AC supply for Power Receptacle O20268-PTD-S -AC-VD-0123(3004B-201-01, 03 OF R 05)/ O20268-PTD-S-AC-1L-0102 Y B N SIZE 8 3.5CX70 Al LENGTH MTRS. 9 70 Power Transformer MB 4CX10 Al 70 1 2 3 4 - R Y B N TB1-47 TB1-48 TB1-49 TB1-46 R Y B N Power Transformer MB OLTC PANEL 4CX10 Al 12 1 2 3 4 TB1-47 TB1-48 TB1-49 TB1-46 R Y B N TB1-25 TB1-26 TB1-27 TB1-28 H30 H31 H32 H33 415V AC supply for OLTC & loop for heater, lighting for 230V supply O20268-PTD-S -AC-VD-0123(3004B-201-01, 03 OF 05)/ O20268-PTD-S-AC-1L-0102; O20268-PTD-S-SY-VD-0516 (18, 22 OF 25) 004 ACDB Power Transformer RTCC PANEL 4CX6 Al 15 1 2 3 4 - R Y B N - R Y B N 415V AC supply for RTCC & loop for heater, lighting for 230V supply O20268-PTD-S -AC-VD-0123(3004B-201-01, 03 OF 05)/ O20268-PTD-S-AC-1L-0102; O20268-PTD-S-SY-VD-0516 (18, 22 OF 25) A 005 ACDB Line Cum Transformer CRP 2CX6 Al 12 1 2 - R N X3:1 X3:2 H1 H2 Line cum Transformer CRP Control Supply O20268-PTD-S-SY-VD-0525_REV.02 (14 21102-6B SH 02 OF 16); 01 A 006 ACDB NIFPS Control Panel_ Power Transformer 4CX6 Al 15 1 2 3 4 SPARE R N E X1-3 X1-4 X1-5 L N PE NIFPS Control Panel AC SUPPLY (Power Transformer ) O20268-PTD-S -AC-VD-0123(3004B-201-01, 03 OF 05)/ O20268-PTD-S-AC-1L-0102; O20268-PTD-S-SY-VD-0518 ( SH 18 OF 73) 6 01 A 007 ACDB SUMP PUMP 4CX10 Al 60 1 2 3 4 - R Y B N - R Y B N P 6 01 A 008 ACDB BMK 3.5CX70 Al 55 1 2 3 4 - R Y B N TB1:1 TB1:2 TB1:3 TB1:4 R Y B N P 6 01 A 009 ACDB FEC Panel - Power Transformer 4CX6 Al 40 1 2 3 4 - R Y B N - R Y B N 1 2 3 4 TB2:1 TB2:2 TB2:3 TB2:4 R2 Y2 B2 N2 TB1-4 TB1-5 TB1-6 TB1-7 H10 H20 H30 H40 415V AC supply for Motor, loop 230V Ac supply for Heater & Lighting 1 2 3 4 TB2:5 TB2:6 TB2:7 TB2:8 R4 Y4 B4 N4 TB1-4 TB1-5 TB1-6 TB1-7 H10 H20 H30 H40 415V AC supply for Motor, loop 230V Ac supply for Heater & Lighting CABLE NO. 1 P 2 6 3 01 4 A 5 001 FROM 6 ACDB P 6 01 A 002 ACDB P 6 01 A 003 P 6 01 A P 6 01 P 6 P P P 6 6 01 01 A A 010 011 BMK BMK Isolator 89A Isolator 89B 4CX6 Al 4CX6 Al 25 15 CORE 10 1 2 3 4 415V AC supply for Power Transformer O20268-PTD-S -AC-VD-0123(3004B-201-01, 03 OF 05)/ O20268-PTD-S-AC-1L-0102; O20268-PTD-S-SYMB loop for heater, lighting for 230V supply VD-0516 (18 OF 25) 415V AC supply for Sump Pump 415V AC supply for BMK; Loop 230V supply for Heating lighting 415V AC supply for FEC Panel O20268-PTD-S -AC-VD-0123(3004B-201-01, 03 OF 05); O20268-PTD-S-AC-1L-0102; O20268-PTD-S -AC-VD-0123(3004B-201-01, 03 OF 05); O20268-PTD-S-AC-1L-0102; O20268-PTD-S-SY-VD-0536(SH 21 0F 27) O20268-PTD-S -AC-VD-0123(3004B-201-01, 03 OF 05); O20268-PTD-S-AC-1L-0102; O20268-PTD-S-SY-VD-0536(SH 21 0F 27); O20268-PTD-S-SY-VD-0520(SH 13 of 21) O20268-PTD-S-SY-VD-0536(SH 21 0F 27); O20268-PTD-S-SY-VD-0520(SH 13 of 21) P 6 01 A 012 BMK SF6 66kV Circuit Breaker 2CX6 Al 15 1 2 TB2:9 TB2:12 X1:6 X1:5 N L X1:6 X1:5 230V AC 1PH Motor Supply O20268-PTD-S-SY-VD-0536(SH 21 0F 27); O20268-PTD-S-SY-VD-0519 (SH 18 OF 59) P 6 01 A 013 BMK SF6 66kV Circuit Breaker 2CX6 Al 15 1 2 TB2:13 TB2:16 X1:8 X1:7 N L X1:8 X1:7 230V Ac supply for Heater & Lighting O20268-PTD-S-SY-VD-0536(SH 21 0F 27); O20268-PTD-S-SY-VD-0519 (SH 18 OF 59) Date Revision 14-02-2022 R0 CONTROL CABLE SCHEDULE FOR 66kV LINE CUM TRANSFORMER FEEDER - (BAY NO- 601) AC/ DC POWER CABLE FOR AUXILIARY SYSTEM CABLE NO. FROM P 6 01 A 014 BMK P 6 01 A 015 ACDB P P P 6 6 6 01 01 01 A A A 016 017 018 P 6 01 A 019 P 6 01 A 020 P P P P P P 6 6 6 6 6 6 01 01 01 01 01 01 A A A A A A EQUIPMENT DESIGNATION TO 021 022 023 024 025 026 TARIFF METERING PANEL Outdoor Normal Lighting Panel- Incomer-1 Outdoor Lightining Panel Outdoor Lightining Panel Outdoor Lightining Panel Outdoor Lightining Panel JB1 JB1 JB2 JB3 UPS DB Outdoor Emergency Lightinin DCDB BARVIN Project SIVA Doc. No. INTERCONNECTION DETAILS FROM FERRULE TO GSECL 40MW SOLAR POWER PLANT O20268-PTD-S-SY-TS-0511 R0 REFERENCE DRAWING DETAILS DRG. NO. / SHEET NO. SIZE LENGTH MTRS. 2CX6 Al 24 1 2 - P N - P N 230V Ac supply for Heater & Lighting 3.5CX70 Al 60 1 2 3 4 - R Y B N TB1-1 TB1-2 TB1-3 TB1-4 R Y B N Outdoor Lightining Panel 1 2 3 4 TB2-3 TB2-4 TB2-5 TB2-6 1R3 1Y3 1B3 1N3 - R Y B N SWITCHYARD LIGHTING SUPPLY JB1 O20268-PTD-S-SY-VD-0529 (Lighting Panel) 1 2 3 4 TB2-7 TB2-8 TB2-9 TB2-10 1R4 1Y4 1B4 1N4 - R Y B N SWITCHYARD LIGHTING SUPPLY JB2 O20268-PTD-S-SY-VD-0529 (Lighting Panel) 1 2 3 4 TB2-11 TB2-12 TB2-13 TB2-14 1R5 1Y5 1B5 1N5 - R Y B N SWITCHYARD LIGHTING SUPPLY JB3 O20268-PTD-S-SY-VD-0529 (Lighting Panel) 4CX6 Al 4CX6 Al 4CX6 Al 20 20 20 CORE FERRULE APPLICATION O20268-PTD-S-SY-VD-0536(SH 21 0F 27); O20268-PTD-S-AC-1L-0102 (ACDB); O20268-PTD-S-SY-VD-0529 (Lighting Panel SH 10 OF 13) 15 1 2 - 1R1 1N1 - R Y 240V 1PH SUPPLY FOR POWER RECEPTACLES O20268-PTD-S-SY-VD-0529 (Lighting Panel) LIGHT FITTINGS FL1 & FL3 4CX6 Al 12 1 2 3 4 - R Y B N FL1 FL3 - - SWITCHYARD LIGHTING FL1 & FL3 O20268-PTD-S-SY-VD-0529 (Lighting Panel); O20268-PTD-S-SY-LT-0507 (Lighting Layout) 1 2 3 4 - R Y B N FL4 FL6 - - SWITCHYARD LIGHTING FL4 & FL6 O20268-PTD-S-SY-VD-0529 (Lighting Panel); O20268-PTD-S-SY-LT-0507 (Lighting Layout) 1 2 3 4 - R Y B N FL7 FL8 FL9 - - SWITCHYARD LIGHTING FL7, FL8 & FL9 O20268-PTD-S-SY-VD-0529 (Lighting Panel); O20268-PTD-S-SY-LT-0507 (Lighting Layout) 1 2 3 4 - R Y B N FL7 FL8 FL9 - - SWITCHYARD LIGHTING FL7, FL8 & FL9 O20268-PTD-S-SY-VD-0529 (Lighting Panel); O20268-PTD-S-SY-LT-0507 (Lighting Layout) 1 2 3 4 - R Y B N TB1-1 TB1-2 TB1-3 TB1-4 R Y B N SWITCHYARD EMERGENCY LIGHTING SUPPLY FROM UPS O20268-PTD-S-SY-VD-0529 (Lighting Panel); O20268-PTD-S-SY-LT-0507 (Lighting Layout) 1 2 3 4 TB2-1 TB2-2 - 2R1 2N1 - - - SWITCHYARD LIGHTING ON UPS O20268-PTD-S-SY-VD-0529 (Lighting Panel); O20268-PTD-S-SY-LT-0507 (Lighting Layout) 1 2 - +VE -VE - +VE -VE 110V DC SUPPLY TO RTCC O20268-PTD-S-SY-VD-0516 LIGHT FITTINGS FL7, FL8 & FL9 JB3 Checked By Approved By M/s. GSECL Client 2CX6 Al LIGHT FITTINGS FL7, FL8 & FL9 JB3 DEMPL 240V 1PH POWER RECEPTACLES LIGHT FITTINGS FL4 & FL6 JB2 O20268-PTD-S Contract No. Prepared By 4CX6 Al 4CX6 Al 4CX6 Al Outdoor Emergency Lightining PanelIncomer-2 4CX6 Al LIGHT FITTINGS FL2 & FL5 4CX6 Al RTCC PANEL POWER TRANSFORMER 2CX6 Al 12 12 12 60 35 22 Date Revision 14-02-2022 R0 CONTROL CABLE SCHEDULE FOR 66kV LINE CUM TRANSFORMER FEEDER - (BAY NO- 601) AC/ DC POWER CABLE FOR AUXILIARY SYSTEM CABLE NO. FROM EQUIPMENT DESIGNATION TO SIZE LENGTH MTRS. DEMPL Checked By BARVIN Project Approved By SIVA Doc. No. CORE O20268-PTD-S Contract No. Prepared By M/s. GSECL Client INTERCONNECTION DETAILS FROM FERRULE TO GSECL 40MW SOLAR POWER PLANT O20268-PTD-S-SY-TS-0511 FERRULE P 6 01 A 027 DCDB LINE CUM TRANSFORMER - C&R PANEL 2CX6 Al 20 1 2 TB3-5 TB3-6 +VE -VE X3-4 X3-5 J1 J2 P 6 01 A 028 DCDB Power Transformer NIFPS Control Panel 2CX6 Al 18 1 2 - +VE -VE X1-1 X1-2 +VE -VE P 6 01 A 029 DCDB Isolator 89A 2CX6 Al 60 1 2 - - TB2-1 TB2-2 P 6 01 A 030 DCDB Isolator 89B 2CX6 Al 50 1 2 - - P 6 01 A 031 DCDB SF6 66kV Circuit Breaker 2CX6 Al 55 1 2 - P 6 01 A 032 DCDB SF6 66kV Circuit Breaker 2CX6 Al 55 1 2 - APPLICATION R0 REFERENCE DRAWING DETAILS DRG. NO. / SHEET NO. 110V DC SUPPLY TO CRP O20268-PTD-S-SY-VD-0525_REV.02 (14 21102-6B SH 02 OF 16); O20268-PTD-S-AC-1L-0102_R02; 110 V DC Supply to NIFPS CONTROL PANEL O20268-PTD-S-AC-1L-0102 DCDB; O20268-PTD-S -AC-VD-0123, NIFPS (SHEET 3,4 OF K1 K2 110 V DC Supply to Isolator 89A O20268-PTD-S-SY-VD-0536(SH 21 0F 27); O20268-PTD-S-SY-VD-0520(SH 13 of 21) TB2-1 TB2-2 K1 K2 110 V DC Supply to Isolator 89B O20268-PTD-S-SY-VD-0536(SH 21 0F 27); O20268-PTD-S-SY-VD-0520(SH 13 of 21) - X1-1 X1-2 +VE -VE 110 V DC Supply-1 trip ckt -1 O20268-PTD-S-SY-VD-0536(SH 21 0F 27); O20268-PTD-S-SY-VD-0519 (SH 18 OF 59) - X1-1 X1-2 +VE -VE 110 V DC Supply-2 trip ckt -2 O20268-PTD-S-SY-VD-0536(SH 21 0F 27); O20268-PTD-S-SY-VD-0519 (SH 18 OF 59)