294604-YTG-G-0511 ® TECHNICAL GUIDE R-410A AFFINITY™ SERIES DEQ, DEX, DEY AND DEZ MODELS 2 - 5 TON 60 Hertz Description These York® Affinity™ packaged air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point of installation. Field-installed electric heater accessories are available to provide electric heat, if required. Tested in accordance with: FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 294604-YTG-G-0511 Table of Contents Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Component Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Guide Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Capacity Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Airflow Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Sound Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Typical Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Weights and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Component Location Cooling Only Direct Drive Condenser Fan Motor Highly Efficient Enhanced Copper Tube/Aluminum Fin Indoor Coil Highly Efficient Enhanced Copper Tube/Enhanced Aluminum Fin OR Micro-Channel Aluminum Tube/Aluminum Fin Condenser Back And Bottom Return Air and Supply Air Duct Opening Decorative Protective Coil Guard High Voltage Terminal Block Low Voltage Terminal Block Long-Lasting Powder Paint Finish High-Efficiency Compressor Rigidly Mounted 2 Direct Drive Blower Motor With Slide-Out Blower Assembly Heavy Gauge Removable Base Rails Johnson Controls Unitary Products 294604-YTG-G-0511 Nomenclature Cooling Only D 2 EZ 024 A 06 Product Category Voltage Code D = Single Package Air Conditioner (Air Cooled) 06 = 208/230-1-60 25 = 208/230-3-60 46 = 460-3-60 58 = 575-3-60 Product Generation 2 = Second Generation Product Identifier EZ = R-410A 13 SEER EQ = R-410A 14 SEER EY = R-410A 14 SEER EX = R-410A 15 SEER Features and Benefits Standard Features • Operating Efficiency - All air conditioners provide operating efficiencies of 13 to 15 SEER. All efficiencies exceed legislated minimum levels. • On Site Flexibility - All model sizes share a common, compact design cabinet in a single footprint. The installer has the flexibility of setting one curb and placing the proper tonnage unit on that curb after the internal load has been determined. Field convertible duct connections from side shot to down shot allows the installer to have greater flexibility with less inventory. • Lower Installation Cost - Installation time and costs are reduced by easy power and control wiring connections. The small base dimension means less space is required on the ground or roof, plus, the installer can fit this unit between the wheel wells of full size pick-up truck. All units are completely wired, charged with R-410A and tested prior to shipment. Unique test stations using a new state of the art computerized process system are used to insure product quality. Refrigerant charge and component part numbers are verified via computers at assembly. Vital run test statistics such as system pressure, motor currents, air velocity and temperature, unit vibration, and gas system safeties are monitored and recorded by the system to insure unit performance. Equal size, side supply and return duct connections allows easy hook-up of ducts to match low crawl spaces without transition pieces. • Utility Connections Made Easy - Electric utility knockouts are provided through the bottom as well as the side of the unit. Utility connections can be made quickly and with a minimum amount of field labor. A field supplied and field installed electrical disconnect switch must be installed. • Convertible Airflow Design - The bottom duct openings are covered when they leave the factory ready to be used for a side supply/side return application. If a bottom supply/bottom return application is desired, you simply remove the two panels from the bottom of the unit and place them in the side supply/side return duct openings. No panel cutting is required and no accessory panel is necessary. Convertible airflow design allows maximum field flexibility and minimum inventory. Johnson Controls Unitary Products Factory Installed Electric Heat A = No Electric Heat Installed Nominal Cooling Capacity (MBH) 024 = 24,000 BTUH 030 = 30,000 BTUH 036 = 36,000 BTUH 042 = 42,000 BTUH 048 = 48,000 BTUH 060 = 60,000 BTUH • Condensate Pan - A non-corrosive, long-lasting, watertight pan is positioned below the evaporator coil to collect and drain all condensate. Less collection of stagnate condensate will build-up. The condensate pan conforms to ASHRAE 62-89 standards (Ventilation for Acceptable Indoor Air Quality). • Condensate Drain - The heavy duty, 3/4 inch NPTI copper connection is more durable over time. The connection is rigidly mounted to assure proper fit and leak tight seal. • Durable Finish - With a heavy duty cabinet made of powder-painted, galvanized steel the neutral color blends into surrounding areas. The powdered paint provides a better paint to steel bond, which resists corrosion and rust creep. The special primer formulas and glossy finish insures less fading when exposed to sunlight and offers a more attractive on site appearance. This paint finish meets ASTM-B117 standards for 1000 hours salt spray rating. The highest in the industry. • Full Perimeter Base Rails - The easily removable base rails provide a solid foundation for the entire unit and protects the unit during shipment. The rails provide fork lift access from all sides, and rigging holes are also provided so that an overhead crane can be used to place the units on a roof. On applications where the unit is placed on a pad, the base will keep the unit off the pad to deter corrosion. On applications where height is limited, the inch high base rails may be removed on location. • More Attractive Appearance - A single piece Water Shed top cover containing a top discharge condenser fan arrangement requires less square footage on installation and provides a wider variety of installations. The one piece design adds greater water integrity. Rounded corners with water drip edges add to the attractive appearance. The cabinet panels have a non-fibrous insulation that will not release insulation fibers into conditioned area. • Top Discharge - The top discharge condenser fan does not disrupt neighboring areas or dry-out vegetation surrounding the unit. The warm air from the top mounted fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications. • Condenser Coil Grille - All DEZ models utilize a decorative “Wire-Form” coil guard to provide impact protection against large objects. All other models utilize a stamped “Louvered” design which provides superior 3 294604-YTG-G-0511 • • • • • • • • • • 4 impact protection against smaller objects during transit and after installation. Low Operating Sound Level - The upward air flow carries the normal operating noise up and away from the living area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and compressor operating sounds. The unique formed base pan also aids in sound alterations with it's Super-Structure design. This design strategically places embossments in the pan for optimum strength and rigidity. Fan System - All models operate over a wide range of design conditions with an electrically commutated fan motor. These units easily match all types of applications and provide greater on site flexibility to match comfort requirement. The cooling speed is factory set and can be field adjusted to a second speed. The heating speed is factory set but can be field adjusted. This allows maximum comfort conditions. Simple Control Circuit - A low voltage printed circuit board contains a diagnostic indicator light and a low voltage terminal strip. An additional set of pin connectors is also provided to simplify the field interface of external controls. Mate-n-lock plug connectors are used. The electrical control box is not located in the compressor compartment. The controls are mounted on a Control-Tilt control panel to allow the access cover to be removed for trouble shooting and maintenance without affecting the normal system operating pressures. All wiring internal to the unit is color/number coded. Protected Compressor - The compressor is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protect the compressor if undesirable operating conditions occur. Pressure Switches - High pressure and low pressure/ loss of charge switches standard in all units. When abnormal conditions are sensed through the pressure switches, the unit will lock out preventing any further operation until reset or problem is corrected. Exclusive Coil Design - Grooved copper tubes and enhanced aluminum fin construction improves heat transfer for maximum efficiency and durability. Self Diagnostic Fan Control Module - Due to this self diagnostic control, less on site time is required to trouble shoot these units. Low Maintenance - Long life, permanently lubricated condenser and evaporator fan motor bearings need no annual maintenance adding greater reliability to the unit. Blower assembly can be easily cleaned by the unique Slip- Track slide-out blower assembly. Secured Service Access Ports - Protected, externally mounted, re-usable service access ports are provided on both the high and low lines for ease of evacuating and charging the system. No final field mounting required. Easy Service Access - A large, single panel covers the electrical controls to make servicing easy. The blower compartment has an additional large panel with a built-in handle tab. Removing this panel will allow the blower assembly to slide-out for easy removal for maintenance and ease of trouble shooting. • Replacement Parts - The installer requires no special training to replace any of the components of these units and does not need to maintain an inventory of unique parts. • System Integration - Each unit has the internal ability to integrate an electronic air cleaner or humidifier to work in conjunction with the base unit. Field Installed Accessories • Economizer Down Discharge/Supply Kit - Modulating integrated economizer provides simultaneous operation between the mechanical cooling and economizer operation. Independent blade design insures proper control and less than 1% leak rate. Includes hood and mesh bird screen filter integrated into the hood, dry bulb sensor and relief damper. Separate field accessories of single enthalpy and dual enthalpy are also available. A built-in barometric relief of 25% is provided. • Single Enthalpy Sensor - Sensor replaces dry bulb sensor standard in economizer kit. Provides improved economizer operation by sensing the dry bulb temperature from outdoors plus the enthalpy content of the outdoor air. • Dual Enthalpy Sensor - Additional sensor to single enthalpy sensor. Sensor senses both the return air temperature dry bulb and humidity in conjunction with the single enthalpy to determine the most economical mix. Single Enthalpy sensor also required. • Hail Guard Kit - Kit contains protective grilles made of expanded aluminum with full perimeter frame. Sloped hoods are also included to assure maximum protection. • Filter/Frame Kit (Single Phase Only) - Kit contains the necessary hardware to field install return air filters into the base unit. Pre-cut filter racks and appropriate cleanable standard size filters are shipped in one kit. The filter rack is suitable for either 1" or 2" filters. (1" filter is supplied) This kit is available for single phase horizontal or vertical duct application only. Standard in all 3 Phase models. • Motorized Fresh Air Damper - Designed for duct mounted side supply/return and unit mounted down supply/return applications. Damper capable of providing 0% through 50% of outdoor air (field supplied). Closes on power loss, includes hood and screen assembly. • Rectangle To Round Adapters - Kit includes one supply and one return air rectangle to round duct adapter. Adapters are preformed and designed to fit over current duct openings on the base unit. Transition is from side square duct opening to 14" round duct opening. • Roof Curbs - NRCA approved curbs provide proper fit to base unit for rooftop installations. Curbs are designed to be assembled through hinge pins in each corner. Kit also provides seal strip to assure a water tight seal. 8 and 14 inch high roof curbs are available. • Manual Outdoor Damper - Provides 0% through 50% outdoor air capability (field adjustable). Designed for duct mounted side supply/return applications. Includes hood and screen assembly. • Wall Thermostat - The units are designed to operate with 24-volt electronic and electro-mechanical thermostats. All units can operate with single stage heat/single stage cool thermostats - with or without the economizer. Johnson Controls Unitary Products 294604-YTG-G-0511 • Low Ambient Kit - Kit provides necessary hardware to convert unit to operate in cooling cycle down to 0º F. Standard unit operation 45º F. • Transformer Kit - Kit provides necessary hardware to provide single phase models from factory furnished 40 VA transformer capability to 75 VA transformer capability. (Required on installations with economizer or motorized damper.) Guide Specifications General Units shall be manufactured by Johnson Controls Unitary Products in an ISO 9001 certified facility. YORK’s Affinity™ package units give you the flexibility and choices you need in today’s market. These packaged air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point of installation. Description Units shall be factory-assembled, single packaged, Electric Cooling units, designed for outdoor mounted installation. For SEER ratings, refer to technical literature. They shall have built in, equal size, field convertible duct connections for down discharge supply/return or horizontal discharge supply/return. The units shall be factory wired, piped, charged with R-410A Refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All units shall be manufactured in a facility certified to ISO 9001 standards, and the cooling performance shall be rated in accordance with DOE and ARI test procedures. Units shall be CSA listed and classified to ANSI Z21.47/CAN/CSA 2.3 standards and UL 1995/CAN/CSA No. 236-M90 conditions. Unit Cabinet Unit cabinet shall be constructed of G90 galvanized steel, with exterior surfaces coated with a non-chalking, powdered paint finish, certified at 1000 hours salt spray test per ASTM-B117 standards. The unit top shall be a single piece “Water Shed” design, with drip edges and no-seam corners to provide optimum water integrity. Unit shall have a rigidly mounted condenser coil guard to provide protection from objects and personnel after installation. Indoor blower section shall be insulated with up to 3/4” thick, aluminum, foil faced insulation, fastened to prevent insulation from entering the air stream. Cabinet panels shall be “large” size, easily removable for servicing and maintenance, with built-in lift handles. Unit shall be built on a formed, “Super-Structure” design base pan, with embossments at critical points to add strength, rigidity and aid in minimizing sound. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging, for truck access and proper sealing on roof curb applications. Base rails shall be removable, when required, to lower unit height. Filters shall be furnished and be accessible through a removable access door, sealed airtight. Units vertical discharge and return duct configuration shall be designed to fit between standard 24” O.C. beams without modification to building structure, duct work and base unit. Condensate pan shall be internally sloped and conform to ASHRAE 62-89 self-draining standards, with 3/4” NPTI copper, ridged mount connection. Johnson Controls Unitary Products Indoor (Evaporator) Fan Assembly Fan shall be direct drive design. Fan wheel shall be double-inlet type with forward-curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant air volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. Fan assembly shall be “Slip Track” (slide-out) design for easy removal and cleaning. Outdoor (Condenser) Fan Assembly The outdoor fan shall be of the direct-driven propeller type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider bracket and shall be statically balanced for smooth operation. The outdoor fan motor shall be totally enclosed with permanently lubricated bearings and internally protected against overload conditions. Refrigerant Components Compressors: a. Shall be fully hermetic type, direct drive, internally protected with internal high-pressure relief and over temperature protection. The hermetic motor shall be suction gas cooled and have a voltage range of +/- 10% of the unit nameplate voltage. b. Shall have internal isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting. Coils: a. Evaporator coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. b. Evaporator coil shall be of the direct expansion, draw through design. c. Condenser coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed or Mircro-Channel aluminum tube, aluminum fins. d. Condenser coil shall be draw through design. Refrigerant Circuit and Refrigerant Safety Components shall include: a. Independent fixed orifice expansion devices. b. Filter/strainer to eliminate any foreign matter. Electric Heating Section (Field Install Accessory) An electric heating section, with nickel chromium elements, shall be provided in a range of 5 thru 25 KW. The heating section shall have a primary limit control(s) (automatic reset) to prevent the heating element system from operating at an excessive temperature. The Heating Section assembly shall slide out of the unit for easy maintenance and service. Units with Electric Heating Sections shall be wired for a single point power supply with branch circuit fusing (where required). 5 294604-YTG-G-0511 Physical Data DEZ024-060 Physical Data Component Nominal Tonnage Models DEZ024 DEZ030 DEZ036 DEZ042 DEZ048 DEZ060 2.0 2.5 3.0 3.5 4.0 5.0 59.2 ARI COOLING PERFORMANCE Gross Capacity @ ARI A point (MBH) 24.4 30.7 35.3 42.8 49.5 ARI net capacity (MBH) 24.0 30.0 34.5 41.5 48.0 57.5 EER 12.62 11.55 11.36 11.78 11.92 11.03 SEER 13.0 13.0 13.0 13.0 13.0 13.0 Nominal CFM 780 1050 1200 1450 1500 1600 System power (KW) 1.90 2.60 3.04 3.52 4.03 5.21 R-410A R-410A R-410A R-410A R-410A R-410A 3-2 3-7 3-6 4-4 4-0 4-8 Length 49 1/8 49 1/8 49 1/8 49 1/8 49 1/8 49 1/8 Width 47 1/4 47 1/4 47 1/4 47 1/4 47 1/4 47 1/4 33 1/2 33 1/2 33 1/2 33 1/2 41 1/2 41 1/2 374 375 379 400 401 405 Recip Recip Recip Recip Recip Scroll 1 1 1 1 1 1 15 Refrigerant type Refrigerant charge (lb-oz) DIMENSIONS (inches) Height OPERATING WT. (lbs.) COMPRESSORS Type Quantity CONDENSER COIL DATA Face area (Sq. Ft.) 11.9 11.9 11.9 11.9 15 Rows 1 1 1 1 1 1 Fins per inch 23 23 23 23 23 23 0.71/18 0.71/18 0.71/18 0.71/18 0.71/18 0.71/18 Tube diameter (in.) Circuitry Type 2-pass Microchannel 2-pass Microchannel 2-pass Microchannel 2-pass Microchannel 2-pass Microchannel 2-pass Microchannel EVAPORATOR COIL DATA Face area (Sq. Ft.) 4.38 4.38 4.38 5.63 5.63 Rows 2 2 2 3 2 5.63 3 Fins per inch 15 15 15 15 16 16 Tube diameter 3/8 3/8 3/8 3/8 3/8 3/8 Circuitry Type Interlaced Interlaced Interlaced Interlaced Interlaced Interlaced Orifice Orifice Orifice Orifice Orifice Orifice Refrigerant control CONDENSER FAN DATA Fan diameter (Inch) 22 22 22 22 22 22 Type Prop Prop Prop Prop Prop Prop Drive type Direct Direct Direct Direct Direct Direct No. speeds 1 1 1 1 1 1 Number of motors 1 1 1 1 1 1 Motor HP each 1/4 1/4 1/4 1/3 1/3 1/3 RPM 850 850 850 1120 1120 1100 Nominal total CFM 1800 1800 2400 3000 3000 3000 DIRECT DRIVE EVAP FAN DATA Quantity Fan Size (Inch) Type 1 1 1 1 1 1 10 x 8 10 x 8 11 x 10 11 x 10 11 x 10 11 x 10 Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal No. speeds 5 5 5 5 5 5 Motor HP each 1/2 1/2 1/2 3/4 3/4 1 Variable Variable Variable Variable Variable Variable 48 48 48 48 48 48 2 - 22 x 14 x 1 2 - 22 x 14 x 1 2 - 22 x 14 x 1 2 - 22 x 14 x 1 2 - 22 x 14 x 1 2 - 22 x 14 x 1 RPM Frame size FILTERS Quantity - Size 6 Johnson Controls Unitary Products 294604-YTG-G-0511 DEQ024-060 Physical Data Component Nominal Tonnage Models DEQ024 DEQ030 DEQ036 DEQ042 DEQ048 DEQ060 2.0 2.5 3.0 3.5 4.0 5.0 59.0 ARI COOLING PERFORMANCE Gross Capacity @ ARI A point (Btu) 23.3 32.3 36.9 43.5 49.3 ARI net capacity (Btu) 23.0 31.0 36.0 42.0 48.0 57.5 EER 12.0 12.0 12.0 12.1 12.2 12.0 SEER 14.3 14.1 14.0 14.2 14.0 14.0 Nominal CFM 800 900 1150 1400 1550 1500 System power (KW) 1.92 2.58 3.00 3.47 3.93 4.79 R-410A R-410A R-410A R-410A R-410A R-410A 5-0 7-8 8-2 7-12 9-8 10-12 Length 49 1/8 49 1/8 49 1/8 49 1/8 49 1/8 49 1/8 Width 47 1/4 47 1/4 47 1/4 47 1/4 47 1/4 47 1/4 Height 33 1/2 33 1/2 33 1/2 41 1/2 41 1/2 41 1/2 346 386 396 406 440 452 Recip Recip Recip Recip Scroll Scroll 1 1 1 1 1 1 16.4 Refrigerant type Refrigerant charge (lb-oz) DIMENSIONS (inches) OPERATING WT. (lbs.) COMPRESSORS Type Quantity CONDENSER COIL DATA Face area (Sq. Ft.) 11.7 11.7 11.7 16.4 16.4 Rows 1 2 2 1 2 2 Fins per inch 20 20 20 20 20 20 Tube diameter (in.) Circuitry Type 3/8 3/8 3/8 3/8 3/8 3/8 Interlaced Interlaced Interlaced Interlaced Interlaced Interlaced 5.63 EVAPORATOR COIL DATA Face area (Sq. Ft.) 4.38 4.38 4.38 5.63 5.63 Rows 2 2 3 3 2 3 Fins per inch 15 15 15 16 16 16 Tube diameter 3/8 3/8 3/8 3/8 3/8 3/8 Circuitry Type Interlaced Interlaced Interlaced Interlaced Interlaced Interlaced Orifice Orifice Orifice Orifice Orifice TX Valve Refrigerant control CONDENSER FAN DATA Fan diameter (Inch) 22 22 22 22 22 22 Type Prop Prop Prop Prop Prop Prop Drive type Direct Direct Direct Direct Direct Direct No. speeds 1 1 1 1 1 1 Number of motors 1 1 1 1 1 1 Motor HP each 1/4 1/4 1/4 1/4 1/3 1/3 RPM 850 850 850 1100 1100 1100 Nominal total CFM 1800 1800 2400 3000 3000 3000 DIRECT DRIVE EVAP FAN DATA Quantity Fan Size (Inch) Type 1 1 1 1 1 1 10 x 8 10 x 8 10 x 8 11 x 10 11 x 10 11 x 10 Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal No. speeds 1 1 1 1 1 1 Motor HP each 1/2 1/2 1/2 3/4 3/4 1 Variable Variable Variable Variable Variable Variable 48 48 48 48 48 48 RPM Frame size FILTERS Quantity - Size 2 - 22 x 14 x 1 2 - 22 x 14 x 1 2 - 22 x 14 x 1 2 - 22 x 14 x 1 2 - 22 x 14 x 1 2 - 22 x 14 x 1 Johnson Controls Unitary Products 7 294604-YTG-G-0511 DEX024-048 Physical Data Component DEX030 2.5 Models DEX036 3.0 DEX042 DEX048 Nominal Tonnage 3.5 4.0 ARI COOLING PERFORMANCE Gross Capacity @ ARI A point (Btu) 23.5 29.2 36.8 44.5 50.8 ARI net capacity (Btu) 23.2 28.6 36.0 43.5 49.0 EER 12.3 12.3 12.3 12.3 12.3 SEER 15 15 15 15 15 Nominal CFM 800 1000 1150 1400 1600 System power (KW) 1.9 2.3 2.9 3.5 4.0 Refrigerant type R-410A R-410A R-410A R-410A R-410A Refrigerant charge (lb-oz) 5-0 8-0 8-0 7-8 10-0 DIMENSIONS (inches) Length 49 1/8 49 1/8 49 1/8 49 1/8 49 1/8 Width 47 1/4 47 1/4 47 1/4 47 1/4 47 1/4 Height 33 1/2 33 1/2 33 1/2 41 1/2 41 1/2 OPERATING WT. (lbs.) 355 390 400 410 440 COMPRESSORS Type Scroll 2-spd Scroll 2-spd Scroll 2-spd Scroll 2-spd Scroll 2-spd Quantity 1 1 1 1 1 CONDENSER COIL DATA Face area (Sq. Ft.) 11.7 11.7 11.7 16.4 16.4 Rows 1 2 2 1 2 Fins per inch 20 20 20 20 20 Tube diameter (in.) 3/8 3/8 3/8 3/8 3/8 Circuitry Type Interlaced Interlaced Interlaced Interlaced Interlaced EVAPORATOR COIL DATA Face area (Sq. Ft.) 4.38 4.38 4.38 5.63 5.63 Rows 2 2 3 3 3 Fins per inch 15 15 15 16 16 Tube diameter 3/8 3/8 3/8 3/8 3/8 Circuitry Type Interlaced Interlaced Interlaced Interlaced Interlaced Refrigerant control TX Valve TX Valve TX Valve TX Valve TX Valve CONDENSER FAN DATA Fan diameter (Inch) 22 22 22 22 22 Type Prop. Prop. Prop. Prop. Prop. Drive type Direct Direct Direct Direct Direct No. speeds 1 1 1 1 1 Number of motors 1 1 1 1 1 Motor HP each 1/4 1/4 1/4 1/4 1/3 RPM 850 850 850 1100 1100 Nominal total CFM 1800 1800 2400 3000 3000 DIRECT DRIVE EVAP FAN DATA Quantity 1 1 1 1 1 Fan Size (Inch) 10 x 8 10 x 8 10 x 8 11 x 10 11 x 10 Type Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal No. speeds 2 2 2 2 2 Motor HP each 1/2 1/2 1/2 3/4 3/4 RPM Variable Variable Variable Variable Variable Frame size 48 48 48 48 48 FILTERS Quantity - Size 2 - 22 x 14 x 1 2 - 22 x 14 x 1 2 - 22 x 14 x 1 2 - 22 x 14 x 1 2 - 22 x 14 x 1 8 DEX024 2.0 Johnson Controls Unitary Products 294604-YTG-G-0511 DEY060 Physical Data Component Models DEY060 5.0 Nominal Tonnage ARI COOLING PERFORMANCE Gross Capacity @ ARI A point (Btu) 60.4 ARI net capacity (Btu) 58.5 EER 11.6 SEER 14.5 Nominal CFM 1750 System power (KW) 5.0 Refrigerant type R-410A Refrigerant charge (lb-oz) 10-8 DIMENSIONS (inches) Length 49 1/8 Width 47 1/4 Height 41 1/2 OPERATING WT. (lbs.) 460 COMPRESSORS Type Scroll 2-spd Quantity 1 CONDENSER COIL DATA Face area (Sq. Ft.) 16.4 Rows 2 Fins per inch 20 Tube diameter (in.) 3/8 Circuitry Type Interlaced EVAPORATOR COIL DATA Face area (Sq. Ft.) 5.63 Rows 3 Fins per inch 16 Tube diameter 3/8 Circuitry Type Interlaced Refrigerant control TX Valve CONDENSER FAN DATA Fan diameter (Inch) 22 Type Prop. Drive type Direct No. speeds 1 Number of motors 1 Motor HP each 1/3 RPM 1100 Nominal total CFM 3000 DIRECT DRIVE EVAP FAN DATA Quantity 1 Fan Size (Inch) 11 x 10 Type Centrifugal No. speeds 2 Motor HP each 1 RPM Variable Frame size 48 FILTERS Quantity - Size 2 - 22 x 14 x 1 Johnson Controls Unitary Products 9 294604-YTG-G-0511 Unit Limitations Size (Tons) 024 (2.0) 030 (2.5) 036 (3.0) Model DEZ, DEQ DEX DEZ, DEQ DEX DEZ DEQ DEX 042 (3.5) DEZ DEQ DEX DEZ 048 (4.0) DEQ DEX DEZ 060 (5.0) DEQ DEY 10 Unit Voltage 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-3-60 460-3-60 575-3-60 208/230-1-60 208/230-3-60 460-3-60 208/230-1-60 208/230-3-60 460-3-60 575-3-60 208/230-1-60 208/230-3-60 460-3-60 208/230-1-60 208/230-3-60 460-3-60 575-3-60 208/230-1-60 208/230-3-60 460-3-60 575-3-60 208/230-1-60 208/230-3-60 460-3-60 208/230-1-60 208/230-3-60 460-3-60 575-3-60 208/230-1-60 208/230-3-60 460-3-60 575-3-60 208/230-1-60 208/230-3-60 460-3-60 Min 187 187 187 187 187 187 432 540 187 187 432 187 187 432 540 187 187 432 187 187 432 540 187 187 432 540 187 187 432 187 187 432 540 187 187 432 540 187 187 432 Unit Limitations Applied Voltage Max 252 252 252 252 252 252 504 630 252 252 504 252 252 504 630 252 252 504 252 252 504 630 252 252 504 630 252 252 504 252 252 504 630 252 252 504 630 252 252 504 Outdoor DB Temp Max (°F) 125 115 125 115 125 125 125 125 115 115 115 125 125 125 125 115 115 115 115 115 115 115 125 125 125 125 115 115 115 115 115 115 115 125 125 125 125 115 115 115 Johnson Controls Unitary Products 294604-YTG-G-0511 Capacity Performance DEZ024-060 Cooling Capacities DEZ024 (2.0 Ton) Air on Evaporator Coil CFM 600 700 800 900 1000 600 700 800 900 1000 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 30.3 28.5 26.6 24.1 23.5 31.8 29.8 27.9 25.3 24.7 33.2 31.2 29.2 26.4 25.8 31.8 29.7 26.9 26.3 32.4 30.3 27.4 26.8 1.2 1.4 1.6 1.4 1.4 1.3 1.5 1.7 1.5 1.5 1.4 1.6 1.8 1.6 1.6 1.8 2.0 1.7 1.7 1.9 2.1 1.9 1.9 8.6 15.0 21.4 23.8 23.5 10.5 17.9 25.4 25.1 24.7 12.4 20.8 29.2 26.4 25.8 21.0 29.7 26.9 26.3 21.2 30.3 27.4 26.8 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 26.8 24.3 21.8 19.5 20.1 28.3 25.6 22.9 20.6 21.2 29.7 26.9 24.1 21.6 22.3 27.0 24.2 21.7 22.3 27.0 24.2 21.8 22.4 2.0 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 2.0 2.0 1.9 1.9 2.1 2.1 2.0 2.0 12.8 16.2 19.6 19.5 20.1 14.3 18.1 21.8 20.6 21.2 15.8 20.0 24.1 21.6 22.3 21.2 24.1 21.7 22.3 22.5 24.2 21.8 22.4 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 6.3 4.0 28.6 1.6 12.7 10.4 8.1 26.4 1.7 19.1 16.8 14.5 12.2 24.2 1.8 19.1 16.2 13.9 11.6 9.3 21.8 1.6 20.1 17.6 15.3 13.0 10.7 21.8 1.6 7.7 5.2 30.0 1.6 15.4 12.9 10.4 27.7 1.7 23.1 20.6 18.1 15.6 25.4 1.8 22.8 20.1 17.6 15.1 12.6 22.9 1.7 23.0 21.7 19.2 16.7 14.2 22.9 1.7 9.1 6.3 31.5 1.7 18.1 15.4 12.7 29.1 1.8 27.1 24.4 21.7 19.0 26.7 1.9 26.4 24.0 21.3 18.6 15.9 24.0 1.7 25.8 25.8 23.1 20.4 17.7 24.1 1.7 17.8 14.6 11.4 29.4 1.9 26.6 23.4 20.3 17.1 27.0 2.0 26.9 23.9 20.7 17.5 14.3 24.3 1.8 26.3 25.5 22.3 19.1 16.0 24.3 1.8 17.5 13.9 10.2 29.7 2.0 26.1 22.5 18.8 15.2 27.2 2.1 27.4 23.7 20.1 16.4 12.8 24.6 1.9 26.8 25.2 21.5 17.9 14.2 24.6 1.9 95°F 10.4 8.0 24.6 2.1 13.8 11.4 9.0 21.9 2.1 17.2 14.8 12.4 10.0 19.2 2.0 19.5 17.7 15.3 12.9 10.5 18.3 2.0 20.1 17.9 15.6 13.2 10.8 18.6 2.0 11.6 8.8 25.5 2.1 15.3 12.6 9.9 22.7 2.1 19.1 16.3 13.6 10.9 19.9 2.0 20.6 19.6 16.9 14.1 11.4 18.9 2.0 21.2 19.9 17.1 14.4 11.7 19.3 2.0 12.8 9.7 26.4 2.1 16.9 13.8 10.7 23.5 2.1 21.0 17.9 14.8 11.8 20.6 2.0 21.6 21.5 18.4 15.3 12.3 19.6 2.0 22.3 21.8 18.7 15.6 12.6 19.9 2.0 17.9 14.6 11.2 23.9 2.1 22.2 18.9 15.6 12.2 20.9 2.1 21.7 21.6 18.3 15.0 11.7 19.9 2.1 22.3 22.1 18.8 15.4 12.1 20.3 2.1 18.9 15.3 11.7 24.2 2.2 23.4 19.9 16.3 12.7 21.2 2.2 21.8 21.8 18.2 14.6 11.0 20.2 2.2 22.4 22.4 18.8 15.2 11.7 20.6 2.2 90 10.7 15.6 20.5 21.7 21.8 12.4 18.0 23.6 22.9 22.9 14.1 20.4 26.7 24.0 24.1 21.1 27.0 24.3 24.3 21.8 27.2 24.6 24.6 12.5 15.3 18.1 18.3 18.6 14.7 17.0 19.3 18.9 19.3 16.9 18.8 20.6 19.6 19.9 20.1 20.9 19.9 20.3 21.4 21.2 20.2 20.6 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 8.3 6.0 13.2 10.9 8.5 18.1 15.8 13.5 11.1 19.3 17.0 14.6 12.3 20.1 17.8 15.4 13.1 9.6 7.0 15.4 12.7 10.1 21.1 18.5 15.9 13.2 21.7 19.9 17.2 14.6 22.1 20.8 18.2 15.5 10.9 8.0 17.5 14.6 11.7 24.1 21.2 18.3 15.4 24.0 22.7 19.8 17.0 24.1 23.8 20.9 18.0 17.8 14.6 11.3 24.4 21.2 17.9 14.7 24.3 22.7 19.5 16.2 24.3 23.8 20.5 17.3 18.2 14.6 11.0 24.8 21.2 17.6 13.9 24.6 22.7 19.1 15.5 24.6 23.8 20.2 16.6 105°F 9.6 7.2 12.9 10.5 8.0 16.2 13.8 11.3 8.9 18.3 16.3 13.8 11.4 18.5 16.2 13.7 11.3 10.9 7.9 14.3 11.5 8.7 17.6 15.1 12.4 9.6 18.9 17.9 15.1 12.4 19.2 17.8 15.0 12.3 12.3 8.6 15.7 12.5 9.4 19.1 16.5 13.4 10.3 19.6 19.5 16.4 13.3 19.9 19.4 16.3 13.2 16.7 13.3 10.0 19.9 17.6 14.2 10.8 19.9 19.9 16.5 13.1 20.3 20.0 16.6 13.2 17.8 14.1 10.5 20.8 18.6 14.9 11.3 20.2 20.2 16.6 12.9 20.6 20.6 16.9 13.3 65 9.9 10.7 12.0 12.9 14.1 15.1 13.0 14.0 11.9 12.9 9.0 8.9 9.6 9.5 10.2 10.1 9.7 9.8 9.3 9.6 11 294604-YTG-G-0511 DEZ024 (2.0 Ton) (Continued) Air on Evaporator Coil CFM 600 700 800 900 1000 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 22.4 19.5 16.6 17.0 17.0 22.8 19.8 16.8 17.2 17.3 23.1 20.1 17.1 17.5 17.6 20.8 17.7 18.1 18.2 21.4 18.2 18.7 18.8 2.3 2.2 2.2 2.2 2.2 2.3 2.2 2.2 2.1 2.1 2.3 2.2 2.2 2.1 2.1 2.3 2.2 2.2 2.2 2.4 2.3 2.3 2.3 12.3 14.4 16.6 17.0 17.0 15.2 16.0 16.8 17.2 17.3 18.0 17.6 17.1 17.5 17.6 19.0 17.7 18.1 18.2 20.4 18.2 18.7 18.8 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 8.8 6.3 20.1 2.4 12.0 9.5 7.1 17.0 2.4 15.2 12.7 10.3 7.9 13.9 2.3 17.0 14.8 12.4 9.9 7.5 15.7 2.3 16.8 14.4 11.9 9.5 7.0 15.5 2.3 10.3 6.9 20.0 2.4 13.2 10.4 7.6 16.9 2.4 16.2 13.9 11.1 8.3 13.8 2.3 17.2 16.2 13.4 10.6 7.8 15.6 2.3 17.2 15.7 12.9 10.1 7.3 15.4 2.3 11.7 7.5 19.9 2.4 14.4 11.3 8.2 16.7 2.3 17.1 15.1 12.0 8.8 13.6 2.3 17.5 17.5 14.4 11.3 8.1 15.5 2.3 17.6 17.0 13.9 10.7 7.6 15.3 2.3 15.6 12.1 8.7 17.7 2.4 17.7 16.2 12.8 9.3 14.4 2.4 18.1 18.1 14.7 11.2 7.8 16.3 2.4 18.2 17.9 14.5 11.0 7.6 16.1 2.4 16.7 13.0 9.2 18.6 2.5 18.2 17.3 13.6 9.9 15.2 2.5 18.7 18.7 14.9 11.2 7.5 17.1 2.5 18.8 18.8 15.0 11.3 7.6 17.0 2.4 90 13.1 13.5 13.9 15.7 15.5 16.1 15.0 13.8 15.6 15.4 19.1 16.4 13.6 15.5 15.3 17.7 14.4 16.3 16.1 18.6 15.2 17.1 17.0 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 8.2 5.5 11.1 8.6 6.1 13.9 11.7 9.3 6.8 15.7 13.4 10.9 8.4 15.2 12.6 10.1 7.7 10.5 6.0 12.1 9.3 6.5 13.8 12.7 9.9 7.1 15.6 14.5 11.6 8.8 15.2 13.6 10.8 8.0 12.8 6.4 13.2 10.0 6.9 13.6 13.6 10.5 7.3 15.5 15.5 12.4 9.2 15.3 14.7 11.5 8.3 14.4 10.9 7.4 14.4 14.4 11.4 7.9 16.3 16.3 12.9 9.4 16.1 15.8 12.3 8.8 15.6 11.8 8.0 15.2 15.2 12.3 8.4 17.1 17.1 13.3 9.5 17.0 17.0 13.2 9.3 65 6.0 5.2 6.0 5.2 6.0 5.1 5.9 5.3 5.7 5.5 1. These capacities are Net Capacities. 2. These ratings include the compressor, condenser fan and supply air blower motors. 12 Johnson Controls Unitary Products 294604-YTG-G-0511 DEZ030 (2.5 Ton) Air on Evaporator Coil CFM 750 875 1000 1125 1250 750 875 1000 1125 1250 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 35.0 33.6 32.2 29.9 29.9 35.9 34.5 33.1 30.7 30.7 36.8 35.4 34.0 31.5 31.5 35.9 34.4 31.9 32.0 36.4 34.9 32.4 32.4 2.5 2.4 2.4 2.4 2.4 2.5 2.4 2.4 2.4 2.3 2.4 2.4 2.4 2.3 2.3 2.5 2.4 2.4 2.4 2.5 2.5 2.4 2.4 16.1 20.8 25.5 29.9 29.9 17.4 22.4 27.4 30.7 30.7 18.7 24.0 29.3 31.5 31.5 25.0 30.8 31.9 32.0 26.0 32.2 32.4 32.4 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 32.5 30.1 27.7 25.1 25.6 33.7 31.2 28.8 26.0 26.6 34.9 32.4 29.8 27.0 27.5 32.5 29.9 27.1 27.7 32.7 30.1 27.3 27.8 2.9 2.8 2.8 2.7 2.7 2.9 2.8 2.8 2.7 2.7 2.9 2.8 2.7 2.7 2.7 2.9 2.8 2.7 2.7 2.9 2.8 2.8 2.8 15.2 19.5 23.8 25.1 25.6 16.7 21.3 25.9 26.0 26.6 18.1 23.1 28.0 27.0 27.5 24.2 29.1 27.1 27.7 25.3 30.1 27.3 27.8 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 13.5 11.0 33.8 2.7 18.2 15.6 13.1 31.9 2.6 22.9 20.3 17.8 15.2 30.0 2.6 26.9 24.3 21.7 19.2 16.6 27.5 2.5 29.9 28.1 25.6 23.0 20.4 27.8 2.5 14.5 11.6 34.8 2.7 19.5 16.6 13.7 32.9 2.6 24.5 21.6 18.7 15.8 30.9 2.6 29.2 25.8 22.9 20.0 17.2 28.4 2.5 30.7 29.9 27.0 24.1 21.2 28.6 2.5 15.5 12.3 35.9 2.7 20.8 17.6 14.4 33.9 2.6 26.1 22.9 19.7 16.5 31.9 2.6 31.5 27.3 24.1 20.9 17.7 29.2 2.5 31.5 31.5 28.5 25.3 22.0 29.5 2.5 21.7 18.3 15.0 34.2 2.7 27.2 23.8 20.5 17.2 32.2 2.6 31.9 28.7 25.4 22.0 18.7 29.5 2.6 32.0 32.0 28.7 25.3 22.0 29.8 2.6 22.6 19.1 15.6 34.6 2.7 28.3 24.8 21.3 17.8 32.5 2.7 32.4 30.1 26.6 23.2 19.7 29.8 2.6 32.4 32.4 28.9 25.4 22.0 30.1 2.6 95°F 12.5 9.8 30.8 3.1 16.8 14.1 11.4 27.9 3.0 21.1 18.4 15.7 12.9 25.1 2.9 24.9 22.2 19.5 16.8 14.1 22.7 2.9 25.6 23.7 21.0 18.3 15.5 23.8 2.9 13.6 10.6 31.5 3.1 18.3 15.2 12.1 28.6 3.0 22.9 19.8 16.7 13.7 25.8 2.9 25.9 23.9 20.9 17.8 14.7 23.3 2.9 26.6 25.5 22.5 19.4 16.3 24.4 2.9 14.7 11.3 32.3 3.1 19.7 16.3 12.9 29.3 3.0 24.6 21.2 17.8 14.4 26.4 2.9 27.0 25.6 22.2 18.8 15.4 23.8 2.9 27.5 27.4 24.0 20.5 17.1 25.0 2.9 20.6 16.9 13.3 29.8 3.0 25.7 22.1 18.5 14.9 26.8 3.0 27.1 26.5 22.9 19.2 15.6 24.2 2.9 27.7 27.6 24.0 20.4 16.8 25.4 2.9 21.4 17.6 13.8 30.3 3.1 26.8 23.0 19.2 15.3 27.2 3.0 27.3 27.3 23.5 19.6 15.8 24.6 3.0 27.8 27.8 24.0 20.2 16.4 25.8 3.0 90 15.7 20.2 24.6 27.5 27.8 17.1 21.9 26.7 28.4 28.6 18.4 23.6 28.7 29.2 29.5 24.6 29.9 29.5 29.8 25.6 31.2 29.8 30.1 14.8 18.9 23.1 22.7 23.8 16.7 20.5 24.3 23.3 24.4 18.7 22.1 25.5 23.8 25.0 23.4 26.4 24.2 25.4 24.7 27.2 24.6 25.8 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 13.0 10.4 17.5 14.9 12.2 22.0 19.4 16.7 14.1 25.9 23.3 20.6 18.0 27.8 25.9 23.3 20.6 14.1 11.1 18.9 15.9 12.9 23.7 20.7 17.7 14.8 27.6 24.9 21.9 18.9 28.6 27.7 24.7 21.8 15.1 11.8 20.2 16.9 13.6 25.4 22.0 18.7 15.4 29.2 26.5 23.2 19.9 29.5 29.5 26.2 22.9 21.1 17.6 14.2 26.4 23.0 19.5 16.0 29.5 27.6 24.1 20.6 29.8 29.8 26.3 22.9 22.0 18.4 14.7 27.5 23.9 20.2 16.6 29.8 28.7 25.1 21.4 30.1 30.1 26.5 22.8 105°F 12.0 9.2 16.1 13.3 10.5 20.3 17.5 14.7 11.9 22.6 20.3 17.5 14.7 23.8 21.8 19.0 16.2 12.9 9.8 17.4 14.2 11.1 21.8 18.7 15.6 12.4 23.2 21.8 18.6 15.5 24.4 23.3 20.2 17.1 13.9 10.4 18.7 15.2 11.7 23.4 19.9 16.4 13.0 23.8 23.2 19.7 16.2 25.0 24.9 21.4 17.9 19.7 16.0 12.3 24.5 21.0 17.2 13.5 24.2 23.9 20.2 16.5 25.4 25.3 21.6 17.9 20.7 16.8 12.8 25.6 22.0 18.1 14.1 24.6 24.6 20.7 16.7 25.8 25.8 21.9 17.9 65 15.3 18.0 15.9 18.8 16.6 19.6 17.2 19.4 17.8 19.2 11.9 13.4 12.3 13.9 12.8 14.5 12.8 14.2 12.7 13.9 13 294604-YTG-G-0511 DEZ030 (2.5 Ton) (Continued) Air on Evaporator Coil CFM 750 875 1000 1125 1250 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 29.0 25.7 22.5 20.3 22.0 29.3 26.0 22.8 20.5 22.2 29.6 26.3 23.0 20.7 22.5 27.1 23.7 21.3 23.1 27.8 24.4 21.9 23.8 3.3 3.2 3.1 3.1 3.1 3.3 3.2 3.1 3.1 3.1 3.3 3.2 3.1 3.0 3.1 3.2 3.1 3.1 3.1 3.3 3.2 3.1 3.2 14.3 18.3 22.3 20.3 22.0 16.8 19.7 22.7 20.5 22.2 19.3 21.2 23.0 20.7 22.5 22.6 23.7 21.3 23.1 24.1 24.4 21.9 23.8 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 11.4 8.5 27.2 3.5 15.4 12.5 9.6 23.5 3.4 19.4 16.5 13.7 10.8 19.9 3.3 20.3 18.4 15.6 12.7 9.8 17.9 3.3 22.0 19.9 17.0 14.1 11.3 20.2 3.3 12.3 9.0 27.1 3.5 16.5 13.3 10.1 23.4 3.4 20.8 17.6 14.4 11.1 19.8 3.3 20.5 19.6 16.4 13.2 10.0 17.7 3.2 22.2 21.2 17.9 14.7 11.5 20.1 3.3 13.1 9.6 27.0 3.5 17.6 14.1 10.5 23.3 3.4 22.1 18.6 15.1 11.5 19.6 3.3 20.7 20.7 17.2 13.7 10.1 17.6 3.2 22.5 22.4 18.9 15.3 11.8 20.0 3.2 18.8 15.0 11.2 24.4 3.4 23.2 19.8 16.0 12.2 20.6 3.3 21.3 21.3 17.5 13.7 9.9 18.4 3.3 23.1 23.1 19.3 15.5 11.7 20.9 3.3 20.0 15.9 11.8 25.4 3.5 24.4 21.0 17.0 12.9 21.5 3.4 21.9 21.9 17.8 13.8 9.7 19.3 3.3 23.8 23.8 19.7 15.6 11.5 21.8 3.4 90 15.5 17.7 19.9 17.9 20.2 18.1 18.9 19.8 17.7 20.1 20.7 20.2 19.6 17.6 20.0 21.9 20.6 18.4 20.9 23.5 21.5 19.3 21.8 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 10.8 7.9 14.7 11.7 8.8 18.6 15.6 12.7 9.7 17.9 16.6 13.6 10.6 20.2 18.0 15.1 12.1 12.2 8.3 15.7 12.4 9.1 19.7 16.5 13.2 9.9 17.7 17.4 14.1 10.8 20.1 19.0 15.7 12.4 13.5 8.7 16.6 13.0 9.4 19.6 17.3 13.7 10.1 17.6 17.6 14.7 11.1 20.0 19.9 16.3 12.7 17.9 14.0 10.1 20.6 18.7 14.8 10.9 18.4 18.4 14.9 10.9 20.9 20.8 16.9 13.0 19.3 15.1 10.9 21.5 20.1 15.8 11.6 19.3 19.3 15.0 10.8 21.8 21.8 17.5 13.3 65 7.6 9.1 7.6 9.1 7.5 9.1 7.0 9.1 6.6 9.1 1. These capacities are Net Capacities. 2. These ratings include the compressor, condenser fan and supply air blower motors. 14 Johnson Controls Unitary Products 294604-YTG-G-0511 DEZ036 (3.0 Ton) Air on Evaporator Coil CFM 900 1050 1200 1300 1400 900 1050 1200 1300 1400 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 43.2 40.7 38.2 35.5 35.6 44.2 41.7 39.1 36.4 36.5 45.3 42.7 40.0 37.2 37.3 42.7 40.1 37.2 37.4 42.7 40.1 37.3 37.4 2.5 2.5 2.4 2.4 2.4 2.6 2.6 2.5 2.5 2.5 2.7 2.6 2.6 2.6 2.6 2.7 2.7 2.6 2.6 2.8 2.8 2.7 2.7 19.7 25.6 31.5 35.5 35.6 21.1 27.3 33.6 36.4 36.5 22.5 29.0 35.6 37.2 37.3 29.5 36.7 37.2 37.4 30.1 37.8 37.3 37.4 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 39.3 36.1 32.9 31.1 31.1 40.2 37.0 33.7 31.9 31.8 41.2 37.8 34.5 32.6 32.5 37.9 34.6 32.7 32.6 38.0 34.7 32.8 32.7 3.0 2.9 2.8 2.8 2.8 3.1 3.0 2.9 2.9 2.9 3.2 3.1 3.0 3.0 3.0 3.2 3.1 3.1 3.1 3.3 3.2 3.1 3.1 18.6 24.0 29.3 31.1 31.1 20.0 25.7 31.4 31.9 31.8 21.5 27.5 33.5 32.6 32.5 28.5 34.1 32.7 32.6 29.4 34.7 32.8 32.7 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 16.7 13.7 41.2 2.7 22.6 19.7 16.7 38.4 2.7 28.5 25.6 22.6 19.6 35.6 2.6 35.2 31.4 28.5 25.5 22.5 33.3 2.6 35.6 33.7 30.7 27.7 24.7 33.3 2.6 17.8 14.5 42.2 2.8 24.0 20.7 17.4 39.3 2.8 30.3 27.0 23.7 20.4 36.4 2.7 36.2 33.1 29.8 26.5 23.3 34.1 2.7 36.5 35.5 32.2 28.9 25.6 34.1 2.7 18.9 15.2 43.2 2.9 25.4 21.8 18.2 40.3 2.9 32.0 28.4 24.7 21.1 37.3 2.8 37.2 34.9 31.2 27.6 24.0 34.9 2.8 37.3 37.3 33.7 30.1 26.5 34.9 2.8 25.8 22.0 18.2 40.3 2.9 32.4 28.6 24.8 21.0 37.3 2.9 37.2 35.6 31.8 28.0 24.2 35.0 2.8 37.4 37.4 33.6 29.8 26.0 35.0 2.9 26.1 22.1 18.2 40.4 3.0 32.8 28.8 24.8 20.9 37.4 3.0 37.3 36.4 32.4 28.5 24.5 35.0 2.9 37.4 37.4 33.4 29.5 25.5 35.0 2.9 95°F 15.5 12.3 36.3 3.2 20.8 17.7 14.6 33.0 3.1 26.2 23.1 20.0 16.8 29.7 3.0 31.1 28.8 25.7 22.6 19.4 28.2 3.0 31.1 29.1 25.9 22.8 19.7 28.1 3.0 16.6 13.1 37.2 3.3 22.3 18.8 15.3 33.8 3.2 28.0 24.5 21.0 17.5 30.4 3.1 31.9 30.5 27.1 23.6 20.1 28.9 3.1 31.8 30.8 27.3 23.9 20.4 28.8 3.1 17.6 13.8 38.1 3.4 23.7 19.8 16.0 34.6 3.3 29.7 25.9 22.0 18.2 31.1 3.2 32.6 32.3 28.4 24.6 20.8 29.6 3.2 32.5 32.5 28.7 24.9 21.0 29.5 3.2 24.4 20.3 16.2 34.7 3.4 30.5 26.5 22.4 18.3 31.2 3.3 32.7 32.5 28.4 24.4 20.3 29.6 3.3 32.6 32.6 28.5 24.5 20.4 29.5 3.3 25.1 20.8 16.4 34.7 3.5 31.4 27.1 22.7 18.4 31.2 3.4 32.8 32.8 28.5 24.1 19.8 29.6 3.3 32.7 32.7 28.4 24.0 19.7 29.6 3.3 90 19.1 24.8 30.4 33.3 33.3 20.6 26.5 32.5 34.1 34.1 22.0 28.3 34.6 34.9 34.9 29.0 35.4 35.0 35.0 29.7 36.2 35.0 35.0 17.5 22.7 27.9 28.2 28.1 19.9 24.6 29.3 28.9 28.8 22.3 26.5 30.6 29.6 29.5 27.4 30.9 29.6 29.5 28.4 31.2 29.6 29.6 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 16.1 13.0 21.7 18.7 15.6 27.4 24.3 21.3 18.2 33.2 30.1 27.1 24.0 33.3 31.4 28.3 25.3 17.2 13.8 23.1 19.7 16.4 29.1 25.7 22.3 18.9 34.0 31.8 28.5 25.1 34.1 33.2 29.8 26.4 18.2 14.5 24.5 20.8 17.1 30.8 27.1 23.4 19.6 34.9 33.6 29.8 26.1 34.9 34.9 31.2 27.5 25.1 21.1 17.2 31.5 27.5 23.6 19.6 35.0 34.1 30.1 26.2 35.0 35.0 31.1 27.1 25.6 21.4 17.3 32.1 27.9 23.8 19.6 35.0 34.6 30.4 26.3 35.0 35.0 30.9 26.8 105°F 14.3 11.1 19.5 16.3 13.2 24.7 21.6 18.4 15.2 28.2 25.8 22.7 19.5 28.1 25.9 22.8 19.6 15.4 11.9 21.0 17.5 13.9 26.6 23.0 19.5 15.9 28.9 27.6 24.1 20.5 28.8 27.7 24.2 20.6 16.6 12.7 22.5 18.6 14.7 28.5 24.5 20.6 16.7 29.6 29.4 25.5 21.5 29.5 29.5 25.6 21.6 23.3 19.1 14.9 29.0 25.1 21.0 16.8 29.6 29.5 25.3 21.1 29.5 29.5 25.3 21.1 24.0 19.5 15.1 29.6 25.7 21.3 16.8 29.6 29.6 25.2 20.8 29.6 29.6 25.1 20.7 65 21.0 22.2 21.7 23.0 22.4 23.8 22.3 23.2 22.1 22.6 16.3 16.4 16.9 17.0 17.6 17.7 16.9 17.0 16.3 16.2 15 294604-YTG-G-0511 DEZ036 (3.0 Ton) (Continued) Air on Evaporator Coil CFM 900 1050 1200 1300 1400 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 33.4 29.9 26.4 25.3 25.2 34.2 30.7 27.1 25.9 25.8 35.1 31.4 27.8 26.5 26.5 31.4 27.7 26.5 26.4 31.4 27.7 26.5 26.4 3.4 3.3 3.2 3.2 3.2 3.5 3.4 3.3 3.3 3.3 3.6 3.5 3.4 3.4 3.4 3.6 3.5 3.5 3.5 3.7 3.6 3.6 3.6 16.4 21.4 26.4 25.3 25.2 19.8 23.4 27.1 25.9 25.8 23.2 25.5 27.8 26.5 26.5 26.4 27.7 26.5 26.4 27.4 27.7 26.5 26.4 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 13.1 9.9 30.4 3.6 18.2 15.0 11.7 26.8 3.5 23.2 20.0 16.8 13.6 23.2 3.4 25.3 22.9 19.6 16.4 13.2 22.3 3.4 25.2 22.8 19.6 16.3 13.1 22.3 3.4 14.3 10.7 31.2 3.7 19.8 16.2 12.5 27.5 3.6 25.3 21.6 18.0 14.4 23.8 3.5 25.9 24.7 21.1 17.4 13.8 22.9 3.5 25.8 24.6 21.0 17.4 13.7 22.8 3.5 15.6 11.5 32.0 3.9 21.4 17.4 13.3 28.2 3.7 27.3 23.2 19.2 15.1 24.4 3.6 26.5 26.5 22.5 18.4 14.4 23.5 3.6 26.5 26.5 22.4 18.4 14.3 23.4 3.6 22.1 17.8 13.5 28.1 3.8 27.5 23.8 19.5 15.2 24.3 3.7 26.5 26.5 22.2 17.9 13.6 23.4 3.7 26.4 26.4 22.1 17.8 13.5 23.4 3.7 22.8 18.3 13.7 28.0 3.9 27.7 24.4 19.9 15.3 24.2 3.8 26.5 26.5 21.9 17.4 12.8 23.4 3.8 26.4 26.4 21.9 17.3 12.7 23.3 3.8 90 17.0 20.1 23.2 22.3 22.3 20.8 22.3 23.8 22.9 22.8 24.6 24.5 24.4 23.5 23.4 25.4 24.3 23.4 23.4 26.4 24.2 23.4 23.3 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 12.0 8.7 16.8 13.6 10.3 21.7 18.5 15.2 11.9 22.3 19.9 16.6 13.3 22.3 19.6 16.4 13.1 14.1 9.5 18.6 14.9 11.1 23.8 20.2 16.5 12.8 22.9 21.8 18.1 14.3 22.8 21.5 17.8 14.1 16.2 10.4 20.3 16.1 12.0 24.4 21.9 17.8 13.6 23.5 23.5 19.5 15.4 23.4 23.4 19.3 15.1 21.0 16.6 12.2 24.3 22.5 18.1 13.7 23.4 23.4 19.1 14.7 23.4 23.4 18.9 14.5 21.7 17.0 12.3 24.2 23.1 18.4 13.8 23.4 23.4 18.7 14.0 23.3 23.3 18.6 13.9 65 10.1 9.8 10.6 10.4 11.2 10.9 10.3 10.1 9.3 9.2 1. These capacities are Net Capacities. 2. These ratings include the compressor, condenser fan and supply air blower motors. 16 Johnson Controls Unitary Products 294604-YTG-G-0511 DEZ042 (3.5 Ton) Air on Evaporator Coil CFM 1050 1225 1400 1550 1700 1050 1225 1400 1550 1700 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 52.2 48.2 44.2 40.5 37.5 54.7 50.5 46.3 42.5 39.3 57.3 52.9 48.5 44.5 41.1 53.1 48.7 44.7 41.3 53.4 48.9 44.9 41.5 3.2 3.1 3.0 3.0 3.0 3.2 3.1 3.0 3.0 3.0 3.2 3.1 3.0 3.0 3.0 3.2 3.1 3.1 3.1 3.3 3.2 3.2 3.2 23.4 29.9 36.4 40.5 37.5 25.7 33.2 40.7 42.5 39.3 28.1 36.5 45.0 44.5 41.1 38.3 47.0 44.7 41.3 40.1 48.9 44.9 41.5 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 45.5 41.4 37.3 33.4 32.8 48.0 43.6 39.3 35.2 34.6 50.4 45.9 41.3 37.0 36.3 45.9 41.3 37.1 36.4 45.9 41.3 37.1 36.4 3.6 3.6 3.5 3.5 3.5 3.7 3.6 3.6 3.5 3.5 3.7 3.6 3.6 3.5 3.5 3.7 3.7 3.6 3.6 3.8 3.7 3.7 3.7 21.8 27.8 33.8 33.4 32.8 24.9 31.2 37.5 35.2 34.6 28.1 34.7 41.3 37.0 36.3 36.7 41.3 37.1 36.4 38.8 41.3 37.1 36.4 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 19.2 15.0 48.8 3.4 25.7 21.5 17.2 44.8 3.3 32.2 27.9 23.7 19.5 40.7 3.3 39.1 33.6 29.3 25.1 20.9 37.0 3.2 37.5 34.2 29.9 25.7 21.5 35.2 3.2 21.3 16.5 51.3 3.4 28.4 23.6 18.8 47.1 3.4 35.6 30.8 26.0 21.2 42.8 3.3 41.8 37.0 32.2 27.4 22.6 38.9 3.3 39.3 37.7 32.9 28.1 23.3 36.9 3.2 23.4 18.0 53.8 3.4 31.2 25.8 20.5 49.4 3.4 39.0 33.6 28.3 22.9 44.9 3.3 44.5 40.4 35.0 29.7 24.3 40.8 3.3 41.1 41.1 35.8 30.4 25.1 38.7 3.3 32.6 26.8 21.0 49.5 3.5 40.7 34.9 29.1 23.3 45.0 3.4 44.7 42.7 36.9 31.1 25.3 40.9 3.4 41.3 41.3 35.6 29.8 24.0 38.9 3.3 33.9 27.7 21.6 49.6 3.6 42.3 36.1 29.9 23.7 45.1 3.5 44.9 44.9 38.7 32.5 26.3 41.0 3.5 41.5 41.5 35.4 29.2 23.0 39.0 3.4 95°F 17.5 13.2 41.7 3.9 23.5 19.2 14.8 37.3 3.8 29.5 25.2 20.8 16.5 32.8 3.7 33.4 30.4 26.1 21.8 17.5 30.1 3.7 32.8 29.8 25.5 21.2 16.9 29.7 3.7 19.6 14.6 44.1 3.9 26.2 21.3 16.3 39.4 3.8 32.9 27.9 22.9 17.9 34.7 3.8 35.2 33.7 28.7 23.7 18.7 31.8 3.7 34.6 33.1 28.1 23.1 18.1 31.4 3.7 21.7 16.0 46.4 4.0 29.0 23.3 17.7 41.5 3.9 36.3 30.6 25.0 19.3 36.6 3.8 37.0 37.0 31.4 25.7 20.0 33.6 3.7 36.3 36.3 30.7 25.0 19.3 33.1 3.7 30.6 24.5 18.4 41.5 4.0 38.3 32.1 26.0 19.9 36.6 3.9 37.1 37.1 30.9 24.8 18.7 33.6 3.8 36.4 36.4 30.2 24.1 18.0 33.1 3.8 32.2 25.6 19.0 41.6 4.1 40.2 33.6 27.1 20.5 36.6 4.0 37.1 37.1 30.5 23.9 17.3 33.6 3.9 36.4 36.4 29.8 23.2 16.6 33.1 3.9 90 22.6 28.9 35.1 37.0 35.2 25.3 32.2 39.1 38.9 36.9 28.1 35.6 43.2 40.8 38.7 37.5 44.1 40.9 38.9 39.5 45.1 41.0 39.0 21.6 26.3 31.1 30.1 29.7 25.7 29.8 33.9 31.8 31.4 29.8 33.2 36.6 33.6 33.1 35.3 36.6 33.6 33.1 37.5 36.6 33.6 33.1 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 18.3 14.1 24.6 20.3 16.0 30.8 26.5 22.3 18.0 36.3 32.0 27.7 23.4 35.2 32.0 27.7 23.5 20.4 15.5 27.3 22.4 17.5 34.2 29.3 24.4 19.5 38.5 35.4 30.5 25.6 36.9 35.4 30.5 25.6 22.5 17.0 30.1 24.6 19.1 37.6 32.1 26.6 21.1 40.8 38.7 33.2 27.7 38.7 38.7 33.2 27.7 31.6 25.6 19.7 39.5 33.5 27.6 21.6 40.9 39.9 33.9 28.0 38.9 38.9 32.9 27.0 33.1 26.7 20.3 41.3 34.9 28.5 22.1 41.0 41.0 34.6 28.2 39.0 39.0 32.6 26.2 105°F 16.3 12.0 22.0 17.7 13.4 27.7 23.4 19.1 14.8 30.1 27.3 23.0 18.7 29.7 26.9 22.6 18.3 18.6 13.4 24.8 19.8 14.8 30.9 26.2 21.2 16.2 31.8 30.4 25.4 20.4 31.4 30.0 25.0 20.0 20.9 14.8 27.5 21.8 16.2 34.1 28.9 23.2 17.5 33.6 33.6 27.9 22.2 33.1 33.1 27.4 21.7 29.2 23.0 16.8 35.1 30.4 24.2 18.1 33.6 33.6 27.4 21.2 33.1 33.1 26.9 20.8 30.8 24.2 17.5 36.1 31.9 25.3 18.6 33.6 33.6 26.9 20.3 33.1 33.1 26.4 19.8 65 19.2 19.2 20.7 20.7 22.2 22.2 22.0 21.0 21.8 19.8 14.4 13.9 15.5 15.0 16.6 16.1 15.1 14.6 13.6 13.1 17 294604-YTG-G-0511 DEZ042 (3.5 Ton) (Continued) Air on Evaporator Coil CFM 1050 1225 1400 1550 1700 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 37.8 33.1 28.4 26.8 26.5 40.2 35.2 30.2 28.4 28.2 42.5 37.2 31.9 30.1 29.8 37.2 31.9 30.1 29.8 37.2 31.9 30.1 29.8 4.2 4.0 3.9 3.9 3.9 4.2 4.1 4.0 3.9 3.9 4.2 4.1 4.0 4.0 4.0 4.2 4.1 4.1 4.1 4.3 4.2 4.2 4.2 21.3 24.9 28.4 26.8 26.5 26.4 28.3 30.2 28.4 28.2 31.5 31.7 31.9 30.1 29.8 33.9 31.9 30.1 29.8 36.2 31.9 30.1 29.8 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 15.2 10.9 34.0 4.4 20.6 16.3 12.0 29.0 4.3 26.0 21.7 17.4 13.1 24.0 4.1 26.8 24.1 19.8 15.5 11.2 23.5 4.1 26.5 23.9 19.6 15.3 11.0 23.4 4.1 17.7 12.2 36.3 4.5 23.3 18.3 13.3 30.9 4.3 29.0 24.4 19.4 14.4 25.6 4.2 28.4 27.1 22.1 17.1 12.2 25.0 4.1 28.2 26.8 21.9 16.9 11.9 25.0 4.2 20.1 13.6 38.5 4.5 26.0 20.3 14.7 32.9 4.4 31.9 27.1 21.4 15.7 27.2 4.2 30.1 30.1 24.4 18.7 13.1 26.6 4.2 29.8 29.8 24.1 18.4 12.8 26.5 4.2 27.7 21.5 15.3 32.9 4.5 31.9 28.7 22.5 16.3 27.2 4.3 30.1 30.1 23.9 17.7 11.5 26.6 4.3 29.8 29.8 23.6 17.4 11.2 26.5 4.3 29.4 22.7 16.0 32.9 4.6 31.9 30.2 23.5 16.8 27.2 4.5 30.1 30.1 23.4 16.6 9.9 26.6 4.4 29.8 29.8 23.1 16.3 9.6 26.5 4.4 90 22.8 23.4 24.0 23.5 23.4 28.0 26.8 25.6 25.0 25.0 33.2 30.2 27.2 26.6 26.5 32.5 27.2 26.6 26.5 32.9 27.2 26.6 26.5 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 14.3 9.8 19.1 14.9 10.6 24.0 20.0 15.7 11.5 23.5 21.0 16.7 12.4 23.4 20.9 16.6 12.4 18.1 11.1 21.8 16.9 11.9 25.6 22.7 17.7 12.7 25.0 23.8 18.8 13.8 25.0 23.7 18.7 13.8 21.8 12.4 24.5 18.9 13.2 27.2 25.3 19.6 14.0 26.6 26.6 20.9 15.2 26.5 26.5 20.8 15.2 26.3 20.1 13.8 27.2 26.9 20.7 14.4 26.6 26.6 20.4 14.1 26.5 26.5 20.3 14.0 28.1 21.3 14.4 27.2 27.2 21.7 14.9 26.6 26.6 19.8 13.0 26.5 26.5 19.7 12.9 65 8.1 8.1 8.9 8.8 9.6 9.5 7.9 7.8 6.2 6.1 1. These capacities are Net Capacities. 2. These ratings include the compressor, condenser fan and supply air blower motors. 18 Johnson Controls Unitary Products 294604-YTG-G-0511 DEZ048 (4.0 Ton) Air on Evaporator Coil CFM 1200 1400 1600 1700 1800 1200 1400 1600 1700 1800 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 59.7 57.1 54.5 49.7 51.4 61.0 58.3 55.7 50.7 52.5 62.3 59.6 56.9 51.8 53.6 59.4 56.7 51.7 53.5 59.2 56.6 51.5 53.3 3.6 3.5 3.5 3.5 3.5 3.6 3.6 3.5 3.5 3.5 3.6 3.6 3.5 3.5 3.5 3.7 3.6 3.6 3.6 3.7 3.7 3.7 3.7 26.9 34.5 42.1 49.7 51.4 29.0 37.1 45.3 50.7 52.5 31.1 39.7 48.4 51.8 53.6 40.3 49.0 51.7 53.5 40.9 49.7 51.5 53.3 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 55.5 51.3 47.2 44.3 45.4 56.4 52.1 47.9 45.0 46.1 57.3 53.0 48.7 45.7 46.8 53.3 49.0 46.0 47.1 53.7 49.3 46.3 47.4 4.2 4.2 4.1 4.0 4.1 4.3 4.2 4.1 4.1 4.1 4.3 4.2 4.1 4.1 4.1 4.3 4.2 4.2 4.2 4.4 4.3 4.3 4.3 24.5 32.2 39.8 44.3 45.4 26.5 34.7 42.8 45.0 46.1 28.5 37.2 45.8 45.7 46.8 38.1 46.9 46.0 47.1 39.0 48.0 46.3 47.4 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 22.8 18.7 57.6 3.9 30.4 26.3 22.2 54.2 3.9 38.0 33.9 29.8 25.7 50.9 3.8 43.2 39.1 35.0 30.9 26.8 47.0 3.8 50.3 46.2 42.1 37.9 33.8 48.4 3.8 24.5 19.9 58.7 3.9 32.6 28.1 23.5 55.2 3.9 40.7 36.2 31.7 27.1 51.8 3.8 47.5 41.8 37.2 32.7 28.2 47.9 3.8 52.0 49.3 44.8 40.2 35.7 49.3 3.8 26.1 21.2 59.8 3.9 34.8 29.8 24.9 56.3 3.9 43.4 38.5 33.6 28.6 52.8 3.8 51.8 44.4 39.5 34.6 29.6 48.7 3.8 53.6 52.4 47.5 42.6 37.6 50.2 3.8 35.2 30.1 25.0 56.4 4.0 43.9 38.9 33.8 28.7 52.9 3.9 51.7 44.8 39.8 34.7 29.6 48.8 3.9 53.5 52.9 47.9 42.8 37.7 50.3 3.9 35.6 30.4 25.2 56.4 4.1 44.5 39.2 34.0 28.8 52.9 4.0 51.5 45.2 40.0 34.8 29.5 48.9 4.0 53.3 53.3 48.2 43.0 37.8 50.4 4.0 95°F 20.1 15.8 54.4 4.6 27.8 23.4 19.1 48.5 4.5 35.4 31.1 26.7 22.4 42.6 4.4 43.0 38.7 34.3 30.0 25.6 41.3 4.3 44.3 39.9 35.6 31.2 26.9 41.7 4.3 21.7 16.8 54.5 4.6 29.8 25.0 20.1 48.6 4.5 38.0 33.1 28.3 23.5 42.7 4.4 44.4 41.2 36.4 31.6 26.7 41.4 4.4 45.5 42.6 37.7 32.9 28.0 41.9 4.4 23.2 17.9 54.7 4.6 31.9 26.5 21.2 48.8 4.5 40.5 35.2 29.9 24.5 42.9 4.5 45.7 43.8 38.5 33.1 27.8 41.6 4.4 46.8 45.2 39.9 34.6 29.2 42.0 4.4 32.6 27.0 21.5 49.7 4.6 41.4 35.8 30.3 24.8 43.7 4.6 46.0 44.6 39.1 33.5 28.0 42.4 4.5 47.1 46.0 40.5 35.0 29.4 42.8 4.5 33.3 27.5 21.8 50.7 4.7 42.2 36.5 30.7 25.0 44.5 4.7 46.3 45.4 39.7 33.9 28.2 43.2 4.6 47.4 46.9 41.1 35.4 29.6 43.7 4.6 90 25.7 33.3 41.0 47.0 48.4 27.8 35.9 44.0 47.9 49.3 29.8 38.5 47.1 48.7 50.2 39.2 48.0 48.8 50.3 39.9 48.8 48.9 50.4 24.3 31.2 38.1 41.3 41.7 27.4 33.6 39.8 41.4 41.9 30.5 36.0 41.5 41.6 42.0 37.2 42.7 42.4 42.8 38.5 43.9 43.2 43.7 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 21.5 17.2 29.1 24.9 20.6 36.7 32.5 28.3 24.0 43.1 38.9 34.7 30.4 47.3 43.1 38.8 34.6 23.1 18.4 31.2 26.5 21.8 39.4 34.7 30.0 25.3 45.9 41.5 36.8 32.1 48.8 45.9 41.3 36.6 24.7 19.5 33.3 28.2 23.1 42.0 36.8 31.7 26.6 48.7 44.1 39.0 33.9 50.2 48.8 43.7 38.6 33.9 28.6 23.3 42.7 37.4 32.0 26.7 48.8 44.7 39.4 34.1 50.3 49.5 44.2 38.9 34.5 29.0 23.5 43.3 37.9 32.4 26.9 48.9 45.3 39.8 34.3 50.4 50.2 44.7 39.2 105°F 19.9 15.4 26.8 22.3 17.8 33.6 29.2 24.7 20.3 40.6 36.1 31.7 27.2 41.1 36.6 32.2 27.7 21.3 16.4 28.6 23.7 18.7 35.9 31.0 26.0 21.1 41.1 38.4 33.4 28.5 41.5 38.9 34.0 29.0 22.8 17.3 30.5 25.1 19.6 38.3 32.8 27.4 21.9 41.6 40.6 35.2 29.7 42.0 41.2 35.8 30.3 31.5 25.8 20.1 39.5 33.7 28.0 22.3 42.4 41.7 36.0 30.3 42.8 42.3 36.6 30.9 32.5 26.5 20.5 40.7 34.7 28.7 22.7 43.2 42.8 36.8 30.8 43.7 43.4 37.4 31.5 65 26.2 30.3 27.5 31.9 28.7 33.4 28.8 33.6 28.9 33.7 22.7 23.3 23.5 24.0 24.3 24.8 24.6 25.2 24.9 25.5 19 294604-YTG-G-0511 DEZ048 (4.0 Ton) (Continued) Air on Evaporator Coil CFM 1200 1400 1600 1700 1800 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 53.3 45.6 37.9 38.4 38.1 52.7 45.1 37.5 37.9 37.7 52.1 44.6 37.1 37.5 37.2 46.2 38.4 38.8 38.6 47.8 39.7 40.2 39.9 4.9 4.8 4.7 4.6 4.6 4.9 4.8 4.7 4.7 4.7 5.0 4.9 4.8 4.7 4.7 5.0 4.9 4.8 4.8 5.1 5.0 4.9 4.9 24.2 30.3 36.4 38.4 38.1 28.4 32.5 36.7 37.9 37.7 32.6 34.8 37.1 37.5 37.2 36.4 38.4 38.8 38.6 37.9 39.7 40.2 39.9 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 19.6 15.1 52.2 5.2 25.7 21.1 16.6 42.8 5.1 31.8 27.2 22.7 18.1 33.3 5.0 38.1 33.5 29.0 24.4 19.9 35.4 4.9 37.9 33.3 28.8 24.2 19.7 34.5 4.9 21.0 15.9 50.9 5.3 27.5 22.4 17.3 41.6 5.1 33.9 28.8 23.8 18.7 32.3 5.0 37.8 35.5 30.4 25.3 20.3 34.4 5.0 37.6 35.3 30.2 25.1 20.0 33.5 4.9 22.4 16.8 49.5 5.3 29.2 23.6 18.0 40.4 5.2 36.0 30.4 24.8 19.2 31.3 5.1 37.5 37.5 31.9 26.3 20.7 33.4 5.0 37.2 37.2 31.6 26.0 20.4 32.4 5.0 30.5 24.6 18.7 42.6 5.3 37.5 31.6 25.8 19.9 33.1 5.2 38.8 38.8 32.9 27.0 21.1 35.2 5.1 38.6 38.6 32.7 26.8 20.9 34.3 5.1 31.7 25.5 19.3 44.9 5.4 39.1 32.9 26.7 20.5 35.0 5.3 40.2 40.2 34.0 27.8 21.6 37.1 5.2 39.9 39.9 33.7 27.5 21.3 36.2 5.2 90 25.3 29.3 33.3 35.4 34.5 30.6 31.5 32.3 34.4 33.5 36.0 33.6 31.3 33.4 32.4 35.5 33.1 35.2 34.3 37.4 35.0 37.1 36.2 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 19.3 14.7 24.7 20.0 15.3 30.0 25.3 20.7 16.0 35.4 31.0 26.3 21.6 34.5 30.0 25.4 20.7 21.9 15.5 26.3 21.1 15.9 31.9 26.7 21.5 16.3 34.4 32.6 27.4 22.2 33.5 31.6 26.4 21.2 24.5 16.3 27.9 22.2 16.4 31.3 28.0 22.3 16.6 33.4 33.4 28.6 22.8 32.4 32.4 27.5 21.8 29.4 23.3 17.3 33.1 29.6 23.5 17.4 35.2 35.2 29.8 23.8 34.3 34.3 28.8 22.7 30.9 24.5 18.1 35.0 31.1 24.6 18.2 37.1 37.1 31.1 24.7 36.2 36.2 30.0 23.6 65 17.0 16.0 17.0 16.0 17.1 16.0 17.7 16.6 18.3 17.2 1. These capacities are Net Capacities. 2. These ratings include the compressor, condenser fan and supply air blower motors. 20 Johnson Controls Unitary Products 294604-YTG-G-0511 DEZ060 (5.0 Ton) Air on Evaporator Coil CFM 1500 1550 1600 1800 2000 1500 1550 1600 1800 2000 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 78.1 71.7 65.2 58.7 51.3 78.7 72.2 65.7 59.1 51.6 79.3 72.7 66.2 59.6 52.0 74.1 67.5 60.7 53.0 75.6 68.8 61.9 54.1 4.6 4.5 4.4 4.3 4.2 4.6 4.5 4.3 4.2 4.2 4.6 4.5 4.3 4.2 4.1 4.6 4.5 4.4 4.3 4.8 4.6 4.5 4.5 35.6 44.2 52.7 58.7 51.3 36.6 45.3 54.0 59.1 51.6 37.5 46.4 55.3 59.6 52.0 49.1 58.5 60.7 53.0 51.9 61.7 61.9 54.1 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 68.5 62.3 56.1 50.7 49.4 69.4 63.1 56.8 51.4 50.0 70.2 63.9 57.5 52.0 50.6 64.5 58.1 52.5 51.1 65.2 58.7 53.1 51.7 5.6 5.4 5.3 5.2 5.1 5.6 5.4 5.2 5.1 5.1 5.5 5.4 5.2 5.1 5.1 5.5 5.4 5.3 5.2 5.7 5.6 5.4 5.4 31.9 40.2 48.4 50.7 49.4 32.7 41.2 49.7 51.4 50.0 33.5 42.3 51.1 52.0 50.6 44.9 54.1 52.5 51.1 47.6 57.1 53.1 51.7 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 29.7 23.9 73.3 5.1 38.3 32.4 26.5 67.0 5.0 46.8 40.9 35.0 29.1 60.6 4.8 56.0 49.4 43.5 37.6 31.7 54.7 4.7 51.3 50.1 44.2 38.3 32.5 50.3 4.7 30.5 24.4 74.0 5.1 39.2 33.1 27.1 67.6 4.9 47.9 41.9 35.8 29.7 61.3 4.8 57.8 50.5 44.5 38.4 32.3 55.2 4.7 51.6 51.3 45.2 39.1 33.1 50.8 4.6 31.2 25.0 74.7 5.1 40.2 33.9 27.7 68.3 4.9 49.1 42.8 36.6 30.3 61.9 4.8 59.6 51.7 45.4 39.2 32.9 55.8 4.7 52.0 52.0 46.2 40.0 33.7 51.3 4.6 42.4 35.6 28.9 69.3 5.1 51.8 45.0 38.3 31.5 62.8 4.9 60.7 54.3 47.6 40.8 34.1 56.6 4.8 53.0 53.0 46.5 39.8 33.0 52.1 4.8 44.6 37.4 30.1 70.4 5.3 54.5 47.2 40.0 32.7 63.7 5.1 61.9 57.0 49.8 42.5 35.3 57.5 5.0 54.1 54.1 46.8 39.6 32.4 52.9 4.9 95°F 26.1 20.4 63.9 6.2 34.4 28.7 22.9 57.6 6.0 42.7 36.9 31.2 25.5 51.3 5.8 50.7 45.7 40.0 34.2 28.5 45.9 5.7 49.4 47.3 41.6 35.9 30.1 45.9 5.7 26.9 21.0 64.7 6.1 35.4 29.5 23.7 58.3 6.0 43.9 38.0 32.2 26.3 51.9 5.8 51.4 47.1 41.2 35.4 29.5 46.5 5.7 50.0 48.8 42.9 37.1 31.2 46.4 5.7 27.6 21.6 65.4 6.1 36.3 30.4 24.4 59.0 5.9 45.1 39.1 33.2 27.2 52.5 5.8 52.0 48.4 42.5 36.5 30.6 47.0 5.7 50.6 50.2 44.2 38.3 32.3 47.0 5.7 38.3 31.7 25.0 59.4 6.1 47.4 40.8 34.2 27.6 52.9 6.0 52.5 50.5 43.9 37.2 30.6 47.4 5.8 51.1 50.9 44.3 37.7 31.0 47.3 5.8 40.3 33.0 25.7 59.9 6.3 49.8 42.5 35.2 27.9 53.3 6.1 53.1 52.6 45.2 37.9 30.6 47.7 6.0 51.7 51.7 44.4 37.1 29.8 47.7 6.0 90 33.8 42.2 50.6 54.7 50.3 34.6 43.3 51.9 55.2 50.8 35.5 44.4 53.2 55.8 51.3 47.0 56.3 56.6 52.1 49.7 59.4 57.5 52.9 29.6 37.8 45.9 45.9 45.9 30.5 38.8 47.2 46.5 46.4 31.3 39.9 48.5 47.0 47.0 42.4 50.5 47.4 47.3 44.8 52.5 47.7 47.7 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 27.9 22.1 36.3 30.5 24.7 44.7 38.9 33.1 27.3 53.4 47.5 41.7 35.9 50.3 48.7 42.9 37.1 28.7 22.7 37.3 31.3 25.4 45.9 40.0 34.0 28.0 54.6 48.8 42.8 36.9 50.8 50.0 44.1 38.1 29.4 23.3 38.2 32.1 26.0 47.1 41.0 34.9 28.8 55.8 50.1 44.0 37.9 51.3 51.3 45.2 39.1 40.3 33.7 27.0 49.6 42.9 36.2 29.5 56.6 52.4 45.7 39.0 52.1 52.1 45.4 38.7 42.4 35.2 27.9 52.1 44.8 37.6 30.3 57.5 54.8 47.5 40.2 52.9 52.9 45.6 38.3 105°F 24.0 18.4 32.2 26.5 20.9 40.3 34.7 29.1 23.5 45.9 42.8 37.1 31.5 45.9 44.2 38.6 33.0 24.7 18.9 33.1 27.3 21.5 41.5 35.7 29.9 24.2 46.5 44.0 38.2 32.5 46.4 45.5 39.7 34.0 25.4 19.5 34.0 28.1 22.2 42.6 36.7 30.8 24.9 47.0 45.2 39.3 33.4 47.0 46.7 40.8 34.9 35.8 29.3 22.8 44.8 38.3 31.8 25.3 47.4 46.3 39.8 33.3 47.3 47.2 40.7 34.2 37.7 30.6 23.4 47.1 39.9 32.8 25.7 47.7 47.4 40.3 33.2 47.7 47.7 40.6 33.5 65 30.1 31.3 30.9 32.1 31.8 33.0 32.4 32.0 32.9 31.1 25.9 27.4 26.7 28.2 27.5 29.0 26.8 27.7 26.1 26.3 21 294604-YTG-G-0511 DEZ060 (5.0 Ton) (Continued) Air on Evaporator Coil CFM 1500 1550 1600 1800 2000 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 59.3 52.9 46.5 41.1 42.5 60.0 53.5 47.0 41.6 42.9 60.6 54.1 47.5 42.0 43.4 54.3 47.7 42.2 43.5 54.5 47.9 42.3 43.7 6.7 6.6 6.4 6.3 6.3 6.7 6.5 6.4 6.3 6.3 6.7 6.5 6.4 6.2 6.2 6.7 6.5 6.4 6.4 6.9 6.7 6.6 6.6 27.4 35.4 43.4 41.1 42.5 28.2 36.4 44.7 41.6 42.9 29.0 37.5 46.0 42.0 43.4 39.8 46.9 42.2 43.5 42.0 47.9 42.3 43.7 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 21.9 16.4 54.7 7.3 29.9 24.4 18.9 48.2 7.1 37.9 32.4 27.0 21.5 41.7 7.0 41.1 39.8 34.3 28.9 23.4 36.3 6.8 42.5 41.1 35.6 30.1 24.6 39.0 6.9 22.5 16.8 55.3 7.3 30.8 25.1 19.4 48.7 7.1 39.0 33.3 27.7 22.0 42.1 7.0 41.6 40.9 35.2 29.6 23.9 36.7 6.8 42.9 42.2 36.5 30.9 25.2 39.4 6.9 23.2 17.3 55.8 7.2 31.6 25.8 19.9 49.2 7.1 40.1 34.2 28.4 22.5 42.5 6.9 42.0 42.0 36.1 30.3 24.4 37.0 6.8 43.4 43.3 37.5 31.6 25.7 39.8 6.8 33.4 27.0 20.6 49.1 7.3 42.2 35.8 29.4 23.0 42.5 7.1 42.2 42.2 35.8 29.4 23.0 37.0 7.0 43.5 43.5 37.1 30.7 24.3 39.7 7.0 35.1 28.2 21.2 49.1 7.4 44.4 37.4 30.5 23.5 42.5 7.3 42.3 42.3 35.4 28.5 21.5 37.0 7.1 43.7 43.7 36.8 29.8 22.9 39.7 7.2 90 25.1 33.0 40.9 36.3 39.0 26.4 34.0 42.1 36.7 39.4 27.7 35.1 42.5 37.0 39.8 37.2 42.5 37.0 39.7 39.3 42.5 37.0 39.7 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 19.7 14.4 27.6 22.3 16.9 35.5 30.2 24.8 19.5 36.3 36.3 31.5 26.2 39.0 37.9 32.6 27.2 20.4 14.8 28.5 22.9 17.3 36.6 31.0 25.4 19.8 36.7 36.7 32.2 26.7 39.4 38.9 33.3 27.8 21.0 15.1 29.3 23.5 17.6 37.6 31.8 26.0 20.1 37.0 37.0 33.0 27.2 39.8 39.8 34.1 28.3 30.9 24.6 18.3 39.6 33.3 27.0 20.7 37.0 37.0 31.7 25.4 39.7 39.7 33.5 27.3 32.5 25.8 19.0 41.6 34.9 28.1 21.4 37.0 37.0 30.5 23.7 39.7 39.7 33.0 26.2 65 20.8 21.9 21.1 22.2 21.3 22.5 19.2 21.0 17.0 19.5 1. These capacities are Net Capacities. 2. These ratings include the compressor, condenser fan and supply air blower motors. 22 Johnson Controls Unitary Products 294604-YTG-G-0511 DEQ024-060 Cooling Capacities DEQ024 (2.0 Ton) Air on Evaporator Coil CFM 600 700 800 900 600 700 800 900 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 27.3 26.2 25.2 23.5 22.6 28.6 27.5 26.3 24.6 23.6 29.8 28.7 27.5 25.8 24.7 30.4 29.1 27.3 26.1 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 10.8 16.0 21.2 23.5 22.6 12.1 18.1 24.1 24.6 23.6 13.3 20.1 26.9 25.8 24.7 19.1 27.0 27.3 26.1 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 24.3 22.5 20.7 18.8 18.9 25.6 23.7 21.7 19.8 19.9 26.8 24.8 22.8 20.7 20.8 26.4 24.2 22.0 22.1 1.9 1.8 1.8 1.8 1.8 1.9 1.8 1.8 1.8 1.8 1.9 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 12.6 16.0 19.4 18.8 18.9 14.1 17.6 21.1 19.8 19.9 15.6 19.2 22.8 20.7 20.8 21.7 24.2 22.0 22.1 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 8.5 6.2 25.8 1.7 13.7 11.4 9.1 24.4 1.7 18.9 16.6 14.4 12.1 22.9 1.7 21.6 17.9 15.6 13.3 11.0 21.2 1.6 22.6 19.7 17.4 15.1 12.8 20.7 1.6 9.7 7.2 27.1 1.7 15.5 13.0 10.5 25.6 1.7 21.4 18.9 16.4 13.9 24.0 1.7 23.7 20.4 17.9 15.4 12.9 22.2 1.6 23.6 22.4 19.8 17.3 14.8 21.8 1.6 10.8 8.1 28.3 1.7 17.4 14.6 11.9 26.7 1.7 23.9 21.2 18.4 15.7 25.1 1.7 25.8 22.9 20.2 17.4 14.7 23.2 1.6 24.7 24.7 22.3 19.6 16.8 22.8 1.6 15.8 12.5 9.2 28.4 1.7 21.7 18.4 15.1 11.8 26.7 1.7 27.3 20.6 17.3 14.0 10.7 24.7 1.6 26.1 23.0 19.7 16.4 13.2 24.1 1.6 95°F 10.3 7.9 22.1 2.0 13.7 11.3 9.0 20.1 2.0 17.1 14.7 12.4 10.1 18.1 1.9 18.8 17.9 15.6 13.2 10.9 16.7 1.9 18.9 18.1 15.8 13.4 11.1 17.1 1.9 11.2 8.4 23.2 2.0 14.8 12.1 9.3 21.1 2.0 18.5 15.7 12.9 10.2 19.0 1.9 19.8 19.1 16.3 13.5 10.8 17.6 1.9 19.9 19.3 16.5 13.8 11.0 17.9 1.9 12.1 9.0 24.3 2.0 16.0 12.8 9.6 22.1 2.0 19.8 16.6 13.5 10.3 19.9 1.9 20.7 20.2 17.0 13.8 10.7 18.4 1.9 20.8 20.5 17.3 14.1 10.9 18.8 1.9 18.3 14.9 11.5 23.6 2.0 22.8 19.4 16.0 12.6 21.2 2.0 22.0 22.6 19.2 15.8 12.4 19.6 1.9 22.1 22.5 19.1 15.7 12.3 20.0 1.9 90 11.7 16.0 20.3 21.2 20.7 13.1 17.8 22.6 22.2 21.8 14.5 19.7 24.8 23.2 22.8 20.4 25.6 24.7 24.1 12.7 15.1 17.5 16.7 17.1 14.6 16.7 18.7 17.6 17.9 16.6 18.2 19.9 18.4 18.8 20.7 21.2 19.6 20.0 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 9.4 7.1 13.7 11.4 9.1 18.0 15.7 13.4 11.1 20.2 17.9 15.6 13.3 20.7 18.9 16.6 14.3 10.4 7.8 15.2 12.6 9.9 19.9 17.3 14.7 12.0 21.7 19.7 17.1 14.5 21.8 20.8 18.2 15.5 11.5 8.5 16.7 13.7 10.8 21.9 18.9 15.9 13.0 23.2 21.6 18.6 15.6 22.8 22.8 19.8 16.8 17.1 13.7 10.4 22.2 18.9 15.6 12.2 24.7 21.6 18.2 14.9 24.1 22.8 19.4 16.1 105°F 9.5 7.2 12.8 10.4 8.1 16.0 13.7 11.4 9.0 16.7 16.0 13.7 11.3 17.1 16.3 13.9 11.6 10.6 7.7 13.9 11.1 8.4 17.2 14.6 11.8 9.1 17.6 17.1 14.3 11.5 17.9 17.3 14.6 11.8 11.6 8.1 15.0 11.8 8.6 18.4 15.5 12.3 9.1 18.4 18.1 14.9 11.7 18.8 18.4 15.2 12.0 17.2 13.8 10.4 20.5 18.1 14.7 11.2 19.6 19.9 16.4 13.0 20.0 20.4 16.9 13.5 65 11.0 11.9 11.8 12.9 12.7 13.9 11.6 12.7 9.0 9.3 8.8 9.0 8.5 8.8 9.6 10.1 23 294604-YTG-G-0511 DEQ024 (2.0 Ton) (Continued) Air on Evaporator Coil CFM 600 700 800 900 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 19.9 17.7 15.5 14.7 15.3 20.8 18.5 16.3 15.3 16.0 21.7 19.4 17.0 16.0 16.7 20.7 18.2 17.2 17.9 2.2 2.1 2.1 2.1 2.1 2.2 2.1 2.1 2.1 2.1 2.2 2.1 2.1 2.1 2.1 2.2 2.1 2.1 2.1 12.8 14.2 15.5 14.7 15.3 15.2 15.7 16.3 15.3 16.0 17.5 17.2 17.0 16.0 16.7 19.6 18.2 17.2 17.9 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 8.8 6.5 17.7 2.4 11.9 9.6 7.2 15.3 2.3 15.0 12.6 10.3 8.0 13.0 2.2 14.7 14.1 11.8 9.5 7.2 12.6 2.2 15.3 14.4 12.1 9.8 7.5 13.5 2.2 10.0 6.9 18.5 2.4 13.0 10.2 7.4 16.0 2.3 16.0 13.5 10.7 8.0 13.5 2.2 15.3 15.0 12.3 9.5 6.8 13.1 2.2 16.0 15.4 12.6 9.9 7.1 14.0 2.2 11.1 7.3 19.2 2.4 14.0 10.8 7.6 16.6 2.3 17.0 14.3 11.1 7.9 14.1 2.2 16.0 16.0 12.8 9.6 6.4 13.6 2.2 16.7 16.3 13.1 9.9 6.7 14.6 2.2 16.1 12.7 9.2 17.9 2.3 18.2 16.8 13.3 9.8 15.2 2.2 17.2 17.2 13.7 10.2 6.8 14.7 2.2 17.9 18.2 14.8 11.3 7.8 15.8 2.2 90 13.6 13.3 13.0 12.6 13.5 16.0 14.8 13.5 13.1 14.0 18.5 16.3 14.1 13.6 14.6 18.2 15.2 14.7 15.8 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 8.9 5.7 11.0 8.7 6.4 13.0 11.6 9.3 7.0 12.6 12.2 9.9 7.6 13.5 12.5 10.2 7.9 10.5 6.1 12.0 9.3 6.5 13.5 12.4 9.6 6.9 13.1 13.0 10.3 7.5 14.0 13.4 10.7 7.9 12.1 6.5 13.1 9.9 6.6 14.1 13.2 10.0 6.8 13.6 13.6 10.7 7.5 14.6 14.3 11.1 7.9 15.1 11.6 8.1 15.2 15.4 11.9 8.4 14.7 14.7 10.9 7.4 15.8 16.1 12.6 9.1 65 5.3 5.6 4.8 5.2 4.3 4.7 3.9 5.6 1. These capacities are Net Capacities. 2. These ratings include the compressor, condenser fan and supply air blower motors. 24 Johnson Controls Unitary Products 294604-YTG-G-0511 DEQ030 (2.5 Ton) Air on Evaporator Coil CFM 925 1000 1075 1150 925 1000 1075 1150 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 38.7 38.6 38.6 34.8 33.1 38.5 38.5 38.4 34.6 32.9 38.3 38.3 38.2 34.4 32.8 38.8 38.8 34.9 33.3 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 18.3 25.0 31.8 34.8 33.1 18.7 25.6 32.5 34.6 32.9 19.1 26.1 33.2 34.4 32.8 26.9 34.4 34.9 33.3 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 35.4 34.1 32.8 28.8 28.7 35.4 34.1 32.8 28.8 28.7 35.5 34.2 32.8 28.8 28.7 34.6 33.3 29.2 29.1 2.6 2.6 2.5 2.5 2.5 2.6 2.6 2.5 2.5 2.5 2.6 2.6 2.6 2.5 2.5 2.6 2.5 2.5 2.5 17.5 23.8 30.1 28.8 28.7 18.2 24.7 31.3 28.8 28.7 18.9 25.7 32.5 28.8 28.7 26.2 32.7 29.2 29.1 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 14.9 11.5 37.1 2.4 21.7 18.3 14.9 36.4 2.3 28.4 25.0 21.7 18.3 35.7 2.3 33.8 30.3 26.9 23.6 20.2 31.8 2.3 33.1 32.5 29.3 25.9 22.5 30.9 2.3 15.2 11.8 37.0 2.4 22.1 18.7 15.2 36.3 2.4 29.0 25.5 22.1 18.6 35.6 2.3 34.6 30.9 27.5 24.0 20.5 31.7 2.3 32.9 32.9 29.8 26.4 22.9 30.8 2.3 15.6 12.0 36.9 2.4 22.6 19.0 15.5 36.2 2.4 29.6 26.0 22.5 18.9 35.5 2.3 35.4 31.5 28.0 24.4 20.9 31.6 2.3 32.8 33.4 30.4 26.8 23.3 30.7 2.3 23.1 19.4 15.6 36.7 2.4 30.2 26.5 22.8 19.0 36.0 2.3 34.9 32.3 28.6 24.9 21.1 32.1 2.3 33.3 33.3 29.7 25.9 22.2 31.2 2.3 95°F 13.9 10.3 33.0 2.8 20.2 16.7 13.1 31.1 2.8 26.6 23.0 19.4 15.9 29.3 2.7 28.5 26.9 23.4 19.8 16.2 25.7 2.7 28.5 27.3 23.8 20.2 16.6 26.0 2.7 14.4 10.7 33.0 2.8 21.0 17.3 13.5 31.1 2.8 27.6 23.8 20.1 16.4 29.3 2.7 28.8 27.9 24.2 20.4 16.7 25.7 2.7 28.7 28.3 24.6 20.9 17.1 26.0 2.7 15.0 11.1 33.0 2.9 21.8 17.9 14.0 31.1 2.8 28.6 24.7 20.8 16.9 29.3 2.7 29.1 28.9 25.0 21.1 17.2 25.7 2.7 28.8 29.3 25.4 21.5 17.6 26.0 2.7 22.1 18.0 13.9 31.5 2.8 29.0 24.8 20.7 16.6 29.7 2.7 29.2 28.8 24.7 20.6 16.5 26.1 2.7 29.1 28.9 24.8 20.7 16.6 26.4 2.7 90 17.9 24.4 31.0 31.8 30.9 18.4 25.2 31.9 31.7 30.8 19.0 25.9 32.8 31.6 30.7 26.5 33.5 32.1 31.2 17.7 22.7 27.7 25.7 26.0 18.8 23.7 28.5 25.7 26.0 20.0 24.6 29.3 25.7 26.0 25.2 29.4 26.1 26.4 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 14.4 10.9 20.9 17.5 14.0 27.5 24.0 20.6 17.1 31.2 28.6 25.1 21.7 30.9 30.0 26.5 23.0 14.8 11.2 21.6 18.0 14.4 28.3 24.7 21.1 17.5 31.7 29.4 25.8 22.2 30.8 30.8 27.2 23.6 15.3 11.6 22.2 18.5 14.7 29.1 25.4 21.6 17.9 32.2 30.2 26.5 22.7 30.7 31.6 27.9 24.2 22.6 18.7 14.8 29.6 25.7 21.7 17.8 32.1 30.6 26.7 22.7 31.2 31.2 27.2 23.3 105°F 13.1 9.5 19.1 15.5 11.9 25.1 21.5 18.0 14.4 25.6 24.3 20.7 17.2 25.9 24.8 21.2 17.6 13.7 9.9 19.9 16.1 12.4 26.2 22.4 18.6 14.9 25.7 25.3 21.5 17.8 26.0 25.8 22.0 18.2 14.2 10.3 20.7 16.7 12.8 27.2 23.2 19.3 15.0 25.9 26.2 22.3 17.7 26.1 26.7 22.8 18.1 21.1 16.9 12.7 27.3 23.4 19.3 15.1 26.1 25.9 21.7 17.6 26.4 26.3 22.1 17.9 65 18.2 19.6 18.6 20.0 19.0 20.5 18.8 19.4 13.6 14.0 14.0 14.5 13.7 14.1 13.4 13.8 25 294604-YTG-G-0511 DEQ030 (2.5 Ton) (Continued) Air on Evaporator Coil CFM 925 1000 1075 1150 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 30.5 28.1 25.7 22.7 23.4 30.5 28.1 25.7 22.7 23.4 30.5 28.1 25.7 22.7 23.4 28.5 26.1 23.0 23.7 3.0 3.0 2.9 2.8 2.8 3.1 3.0 2.9 2.9 2.9 3.1 3.0 2.9 2.9 2.9 3.0 2.9 2.9 2.9 17.9 21.6 25.4 22.7 23.4 19.5 22.6 25.7 22.7 23.4 21.0 23.6 26.1 22.7 23.4 24.2 26.1 23.0 23.7 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 12.3 8.7 28.0 3.3 18.0 14.4 10.8 25.1 3.2 23.7 20.1 16.5 12.9 22.2 3.1 22.7 21.7 18.1 14.5 10.9 19.6 3.0 23.3 22.3 18.7 15.0 11.4 20.7 3.0 12.9 9.1 28.0 3.3 18.8 15.0 11.2 25.1 3.2 24.7 21.0 17.2 13.4 22.2 3.1 22.7 22.7 18.9 15.1 11.3 19.6 3.0 23.4 23.2 19.4 15.6 11.8 20.7 3.0 13.4 9.4 28.0 3.3 19.6 15.6 11.7 25.1 3.2 25.8 21.8 17.8 13.9 22.2 3.1 22.7 23.6 19.6 15.7 11.7 19.6 3.1 23.4 24.2 20.2 16.2 12.3 20.7 3.1 20.0 15.8 11.6 25.4 3.2 25.7 22.0 17.8 13.6 22.5 3.1 23.0 23.0 18.8 14.5 10.3 19.9 3.0 23.7 23.6 19.4 15.2 11.0 21.0 3.1 90 18.8 20.5 22.2 19.6 20.7 20.9 21.5 22.2 19.6 20.7 22.9 22.5 22.2 19.6 20.7 23.2 22.5 19.9 21.0 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 12.3 7.9 16.9 13.3 9.6 21.8 18.6 15.0 11.4 19.6 19.0 15.5 11.9 20.7 19.7 16.1 12.5 13.2 8.2 17.7 13.9 10.1 22.2 19.5 15.7 11.9 19.6 19.6 16.2 12.4 20.7 20.7 16.9 13.0 14.1 8.6 18.5 14.5 10.5 22.6 20.4 16.4 12.0 19.6 20.3 17.0 12.0 20.7 21.6 17.6 12.7 18.9 14.7 10.4 22.5 20.6 16.3 12.1 19.9 19.9 15.8 11.5 21.0 21.0 16.7 12.4 65 8.3 8.8 8.6 9.2 7.9 8.7 7.2 8.2 1. These capacities are Net Capacities. 2. These ratings include the compressor, condenser fan and supply air blower motors. 26 Johnson Controls Unitary Products 294604-YTG-G-0511 DEQ036 (3.0 Ton) Air on Evaporator Coil CFM 1000 1100 1200 1300 1000 1100 1200 1300 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 46.0 44.1 42.2 39.0 32.9 46.5 44.6 42.6 39.4 33.3 47.0 45.0 43.1 39.8 33.6 44.7 42.8 39.6 33.4 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 23.9 29.4 34.9 39.0 32.9 24.9 30.6 36.3 39.4 33.3 25.8 31.8 37.7 39.8 33.6 34.1 41.5 39.6 33.4 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 40.8 38.2 35.7 31.9 28.3 41.3 38.7 36.2 32.3 28.7 41.9 39.3 36.6 32.7 29.0 39.6 36.9 33.0 29.3 2.8 2.8 2.8 2.7 2.7 2.8 2.8 2.8 2.7 2.7 2.8 2.8 2.8 2.7 2.7 2.8 2.8 2.7 2.7 20.6 27.1 33.6 31.9 28.3 21.7 28.4 35.1 32.3 28.7 22.9 29.8 36.6 32.7 29.0 30.9 36.9 33.0 29.3 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 20.3 16.4 43.4 2.6 25.6 21.7 17.9 41.2 2.5 30.9 27.0 23.1 19.3 38.9 2.5 38.3 34.5 30.7 26.8 23.0 35.4 2.5 32.9 32.6 28.7 24.9 21.0 30.6 2.5 21.0 16.7 43.9 2.6 26.3 22.1 17.8 41.7 2.5 31.6 27.4 23.1 18.8 39.4 2.5 39.1 35.0 30.8 26.5 22.2 35.8 2.5 33.3 33.1 28.8 24.6 20.3 31.0 2.5 21.7 17.1 44.4 2.6 27.1 22.4 17.7 42.1 2.5 32.4 27.7 23.0 18.3 39.9 2.5 39.8 35.6 30.9 26.2 21.5 36.3 2.5 33.6 33.6 28.9 24.3 19.6 31.3 2.5 29.0 24.0 18.9 42.1 2.6 34.8 29.8 24.7 19.7 39.9 2.5 39.6 38.1 33.1 28.0 23.0 36.3 2.5 33.4 33.4 28.4 23.3 18.3 31.3 2.5 95°F 15.9 11.3 37.9 3.1 22.6 18.0 13.5 34.7 3.0 29.3 24.8 20.2 15.7 31.4 3.0 31.9 28.9 24.4 19.9 15.3 28.8 2.9 28.3 26.0 21.4 16.9 12.4 26.6 2.9 16.7 12.0 38.3 3.1 23.8 19.1 14.5 35.1 3.0 30.9 26.2 21.6 16.9 31.8 3.0 32.3 30.6 26.0 21.3 16.6 29.1 2.9 28.7 27.5 22.8 18.2 13.5 26.9 2.9 17.5 12.7 38.8 3.1 25.0 20.2 15.4 35.5 3.0 32.5 27.7 22.9 18.1 32.2 3.0 32.7 32.3 27.5 22.7 18.0 29.5 2.9 29.0 29.0 24.2 19.5 14.7 27.3 2.9 25.7 20.6 15.4 35.8 3.1 33.4 28.2 23.0 17.9 32.5 3.0 33.0 32.9 27.8 22.6 17.5 29.8 2.9 29.3 29.3 24.1 19.0 13.8 27.5 3.0 90 22.3 28.3 34.3 35.4 30.6 23.3 29.5 35.7 35.8 31.0 24.3 30.8 37.2 36.3 31.3 32.5 39.2 36.3 31.3 21.3 25.8 30.4 28.8 26.6 23.1 27.2 31.3 29.1 26.9 25.0 28.6 32.2 29.5 27.3 30.3 32.5 29.8 27.5 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 18.1 13.9 24.1 19.9 15.7 30.1 25.9 21.7 17.5 35.1 31.7 27.5 23.3 30.6 29.3 25.1 20.9 18.8 14.4 25.0 20.6 16.1 31.3 26.8 22.3 17.9 35.7 32.8 28.4 23.9 31.0 30.3 25.8 21.4 19.6 14.9 26.0 21.3 16.5 32.4 27.7 23.0 18.2 36.3 33.9 29.2 24.5 31.3 31.3 26.6 21.9 27.4 22.3 17.2 34.1 29.0 23.9 18.8 36.3 35.5 30.4 25.3 31.3 31.3 26.2 21.1 105°F 15.6 11.1 21.4 17.0 12.6 27.3 23.0 18.6 14.2 28.8 26.4 22.0 17.6 26.6 24.6 20.2 15.8 16.5 11.7 22.6 18.0 13.3 28.7 24.2 19.6 15.0 29.1 27.9 23.2 18.6 26.9 25.9 21.3 16.7 17.3 12.3 23.7 18.9 14.0 30.1 25.4 20.6 15.8 29.5 29.3 24.4 19.6 27.3 27.3 22.4 17.6 25.0 19.8 14.6 30.7 26.7 21.5 16.3 29.8 29.7 24.5 19.3 27.5 27.5 22.3 17.1 65 19.1 16.7 19.4 16.9 19.7 17.1 20.2 16.0 13.2 11.4 14.0 12.1 14.7 12.7 14.1 11.9 27 294604-YTG-G-0511 DEQ036 (3.0 Ton) (Continued) Air on Evaporator Coil CFM 1000 1100 1200 1300 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 35.0 31.1 27.2 25.7 25.0 35.3 31.4 27.4 26.0 25.2 35.7 31.7 27.7 26.2 25.5 32.1 28.1 26.6 25.8 3.3 3.3 3.2 3.1 3.1 3.3 3.3 3.2 3.1 3.1 3.4 3.3 3.2 3.1 3.1 3.3 3.2 3.2 3.2 22.0 24.6 27.2 25.7 25.0 24.5 26.0 27.4 26.0 25.2 27.0 27.4 27.7 26.2 25.5 29.6 28.1 26.6 25.8 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 15.3 10.9 32.1 3.6 20.3 16.0 11.8 27.5 3.5 25.3 21.2 16.9 12.7 22.9 3.4 25.7 24.0 19.7 15.4 11.2 22.6 3.3 25.0 23.3 19.0 14.8 10.5 23.3 3.3 16.2 11.4 32.3 3.6 21.4 16.8 12.2 27.7 3.5 26.5 22.2 17.6 13.0 23.1 3.4 26.0 25.1 20.5 15.9 11.3 22.8 3.3 25.2 24.4 19.8 15.2 10.6 23.5 3.3 17.2 11.9 32.6 3.6 22.5 17.6 12.7 27.9 3.5 27.7 23.2 18.3 13.4 23.3 3.4 26.2 26.2 21.3 16.4 11.5 23.0 3.4 25.5 25.5 20.6 15.7 10.8 23.7 3.4 24.4 19.1 13.8 28.4 3.6 28.1 25.2 19.9 14.7 23.7 3.4 26.6 26.6 21.3 16.0 10.7 23.4 3.4 25.8 25.8 20.6 15.3 10.0 24.1 3.4 90 23.7 23.3 22.9 22.6 23.3 26.4 24.7 23.1 22.8 23.5 29.1 26.2 23.3 23.0 23.7 28.4 23.7 23.4 24.1 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 15.7 10.7 19.2 15.0 10.9 22.8 19.4 15.3 11.2 22.6 21.5 17.3 13.2 23.3 22.0 17.8 13.7 17.4 11.1 20.2 15.6 11.1 23.1 20.2 15.6 11.1 22.8 22.3 17.8 13.2 23.5 22.8 18.3 13.7 19.2 11.5 21.2 16.3 11.3 23.3 21.0 16.0 11.0 23.0 23.0 18.2 13.2 23.7 23.7 18.8 13.8 23.7 18.4 13.0 23.7 23.7 18.4 13.1 23.4 23.4 18.0 12.7 24.1 24.1 18.8 13.4 65 9.1 9.6 8.7 9.2 8.3 8.8 7.4 8.1 1. These capacities are Net Capacities. 2. These ratings include the compressor, condenser fan and supply air blower motors. 28 Johnson Controls Unitary Products 294604-YTG-G-0511 DEQ042 (3.5 Ton) Air on Evaporator Coil CFM 1200 1300 1400 1500 1200 1300 1400 1500 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 58.6 54.7 50.8 46.3 45.4 58.7 54.8 50.9 46.3 45.4 58.7 54.8 50.9 46.3 45.4 55.8 51.8 47.2 46.2 2.9 2.8 2.8 2.7 2.6 2.9 2.8 2.7 2.7 2.5 2.9 2.8 2.7 2.7 2.5 2.8 2.8 2.7 2.5 27.7 36.7 45.7 46.3 45.4 27.9 37.7 47.6 46.3 45.4 28.1 38.8 49.4 46.3 45.4 41.3 51.1 47.2 46.2 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 51.2 46.8 42.5 39.3 39.3 51.3 47.0 42.7 39.4 39.5 51.5 47.2 42.8 39.5 39.6 47.3 42.9 39.6 39.7 3.4 3.3 3.2 3.2 3.1 3.4 3.3 3.2 3.2 3.1 3.4 3.3 3.2 3.1 3.1 3.3 3.2 3.1 3.1 27.9 34.2 40.6 39.3 39.3 29.7 35.7 41.7 39.4 39.5 31.5 37.2 42.8 39.5 39.6 38.3 42.9 39.6 39.7 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 23.2 17.8 54.9 3.2 31.3 25.8 20.4 50.8 3.1 39.3 33.9 28.4 23.0 46.7 3.0 46.2 42.8 37.3 31.9 26.5 42.8 2.9 45.4 43.0 37.5 32.1 26.7 42.3 2.9 23.9 18.3 55.0 3.2 32.1 26.6 21.0 50.9 3.1 40.4 34.8 29.2 23.6 46.8 3.0 46.3 44.0 38.4 32.8 27.2 42.9 2.9 45.4 44.2 38.6 33.0 27.4 42.4 2.8 24.5 18.8 55.1 3.2 33.0 27.3 21.5 51.0 3.1 41.5 35.8 30.0 24.3 46.8 3.0 46.3 45.2 39.4 33.7 27.9 42.9 2.9 45.4 45.4 39.7 33.9 28.2 42.5 2.8 35.1 28.9 22.8 51.5 3.1 44.1 38.0 31.8 25.7 47.4 3.0 47.2 46.6 40.5 34.3 28.2 43.4 2.9 46.2 46.2 40.1 33.9 27.8 43.0 2.8 95°F 21.3 15.6 46.6 3.7 28.6 22.9 17.2 42.2 3.6 35.8 30.1 24.5 18.8 37.8 3.5 39.2 35.8 30.1 24.4 18.8 34.7 3.4 39.3 36.8 31.1 25.4 19.7 35.2 3.4 22.2 16.2 46.9 3.7 29.7 23.7 17.8 42.5 3.6 37.3 31.3 25.3 19.3 38.1 3.4 39.4 37.2 31.2 25.2 19.2 34.9 3.4 39.5 38.2 32.2 26.2 20.3 35.5 3.4 23.1 16.8 47.2 3.7 30.9 24.6 18.3 42.8 3.6 38.7 32.4 26.2 19.9 38.4 3.4 39.5 38.5 32.3 26.0 19.7 35.2 3.4 39.6 39.6 33.3 27.0 20.8 35.7 3.4 31.6 25.0 18.3 42.6 3.6 39.6 32.9 26.2 19.6 38.2 3.4 39.6 39.1 32.4 25.8 19.1 35.0 3.4 39.7 39.7 33.0 26.4 19.7 35.6 3.4 90 27.8 35.5 43.1 42.8 42.3 28.8 36.7 44.6 42.9 42.4 29.8 38.0 46.1 42.9 42.5 39.8 47.0 43.4 43.0 28.1 32.5 36.9 34.7 35.2 30.4 34.0 37.6 34.9 35.5 32.7 35.5 38.4 35.2 35.7 36.4 38.2 35.0 35.6 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 22.3 16.7 29.9 24.4 37.6 32.0 26.5 20.9 42.7 39.3 33.7 28.2 42.3 39.9 34.3 28.8 23.0 17.2 30.9 25.2 19.4 38.8 33.1 27.3 21.5 42.8 40.6 34.8 29.0 42.4 41.2 35.4 29.6 23.8 17.8 32.0 25.9 19.9 40.1 34.1 28.1 22.1 42.9 41.9 35.8 29.8 42.5 42.5 36.5 30.5 33.4 27.0 20.5 41.8 35.4 29.0 22.6 43.4 42.9 36.5 30.0 43.0 43.0 36.6 30.1 105°F 20.0 14.1 26.8 21.2 15.5 33.7 28.3 22.6 16.9 34.7 31.7 26.1 20.4 35.2 33.0 27.3 21.7 21.1 14.6 28.0 22.0 16.1 35.0 29.5 23.5 17.5 34.9 33.0 27.1 21.1 35.5 34.4 28.4 22.4 22.1 15.2 29.2 22.9 16.6 36.3 30.6 24.3 18.1 35.2 34.4 28.1 21.8 35.7 35.7 29.4 23.2 29.7 23.0 16.3 36.5 30.7 24.0 17.3 35.0 34.5 27.8 21.1 35.6 35.6 28.9 22.2 65 22.6 23.2 23.2 23.8 23.8 24.5 23.6 23.7 14.7 16.0 15.1 16.4 15.5 16.9 14.4 15.5 29 294604-YTG-G-0511 DEQ042 (3.5 Ton) (Continued) Air on Evaporator Coil CFM 1200 1300 1400 1500 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 42.0 37.6 33.2 30.1 31.2 42.4 38.0 33.5 30.4 31.5 42.9 38.4 33.9 30.8 31.9 38.0 33.5 30.4 31.5 4.0 3.8 3.7 3.6 3.6 4.0 3.8 3.7 3.6 3.6 4.0 3.8 3.7 3.6 3.6 3.8 3.7 3.6 3.6 28.4 30.8 33.2 30.1 31.2 31.1 32.3 33.5 30.4 31.5 33.8 33.9 33.9 30.8 31.9 34.5 33.5 30.4 31.5 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 18.7 12.5 37.4 4.2 25.1 19.5 13.8 32.9 4.0 31.5 26.4 20.7 15.1 28.5 3.9 30.1 27.6 22.0 16.3 10.7 25.5 3.8 31.2 29.2 23.5 17.9 12.2 27.1 3.9 19.9 13.1 38.0 4.2 26.3 20.3 14.4 33.5 4.0 32.7 27.6 21.6 15.7 29.0 3.9 30.4 28.9 22.9 16.9 11.0 26.0 3.8 31.5 30.5 24.5 18.6 12.6 27.5 3.9 21.2 13.7 38.6 4.2 27.5 21.2 14.9 34.0 4.1 33.9 28.8 22.5 16.2 29.5 3.9 30.8 30.2 23.9 17.6 11.3 26.4 3.8 31.9 31.9 25.6 19.3 13.0 28.0 3.9 27.8 21.0 14.3 33.3 4.0 33.5 28.5 21.8 15.1 28.8 3.9 30.4 29.9 23.1 16.4 9.7 25.9 3.8 31.5 31.5 24.8 18.1 11.3 27.4 3.9 90 29.6 29.0 28.5 25.5 27.1 32.2 30.6 29.0 26.0 27.5 34.9 32.2 29.5 26.4 28.0 32.6 28.8 25.9 27.4 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 18.3 11.0 23.4 17.7 12.1 28.5 24.5 18.9 13.2 25.5 23.5 17.9 12.3 27.1 25.4 19.7 14.1 20.3 11.5 24.6 18.7 12.7 29.0 25.8 19.8 13.8 26.0 24.8 18.8 12.8 27.5 26.7 20.7 14.7 22.3 12.1 25.9 19.6 13.2 29.5 27.0 20.7 14.4 26.4 26.0 19.7 13.4 28.0 28.0 21.7 15.4 25.8 19.1 12.3 28.8 26.4 19.6 12.8 25.9 25.3 18.5 11.8 27.4 27.4 20.7 13.9 65 6.6 8.5 6.8 8.8 7.0 9.0 5.0 7.2 1. These capacities are Net Capacities. 2. These ratings include the compressor, condenser fan and supply air blower motors. 30 Johnson Controls Unitary Products 294604-YTG-G-0511 DEQ048 (4.0 Ton) Air on Evaporator Coil CFM 1400 1500 1600 1700 1400 1500 1600 1700 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 56.8 54.4 51.9 48.9 47.3 56.7 54.3 51.9 48.9 47.3 56.6 54.2 51.8 48.8 47.2 55.2 52.8 49.7 48.1 2.9 2.8 2.7 2.8 2.7 2.9 2.8 2.7 2.8 2.7 2.9 2.8 2.7 2.8 2.7 2.8 2.8 2.8 2.8 26.1 35.7 45.3 48.9 47.3 26.8 36.7 46.6 48.9 47.3 27.6 37.7 47.9 48.8 47.2 38.2 48.7 49.7 48.1 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 53.5 50.5 47.5 44.5 44.6 53.9 50.9 47.9 44.8 44.9 54.4 51.3 48.3 45.2 45.3 51.4 48.4 45.3 45.4 3.5 3.5 3.6 3.5 3.5 3.5 3.5 3.6 3.5 3.5 3.5 3.5 3.6 3.5 3.5 3.5 3.6 3.5 3.5 27.0 35.1 43.3 44.5 44.6 28.0 36.5 44.9 44.8 44.9 29.0 37.8 46.6 45.2 45.3 38.8 47.7 45.3 45.4 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 21.1 16.2 55.1 3.2 30.7 25.8 20.8 52.4 3.2 40.4 35.4 30.4 25.5 49.7 3.2 46.6 42.1 37.1 32.2 27.2 46.7 3.2 47.3 45.5 40.5 35.5 30.6 46.0 3.1 21.7 16.6 55.3 3.2 31.6 26.5 21.4 52.6 3.2 41.5 36.4 31.3 26.2 49.9 3.2 47.7 43.3 38.2 33.1 28.0 46.9 3.2 47.3 46.4 41.7 36.6 31.5 46.1 3.1 22.3 17.1 55.5 3.2 32.5 27.2 22.0 52.8 3.2 42.7 37.4 32.2 26.9 50.1 3.2 48.8 44.5 39.2 34.0 28.8 47.0 3.2 47.2 47.2 42.8 37.6 32.3 46.3 3.1 32.9 27.5 22.1 53.3 3.2 43.2 37.8 32.4 27.0 50.6 3.2 49.7 45.1 39.8 34.4 29.0 47.5 3.2 48.1 48.1 43.1 37.7 32.3 46.7 3.1 95°F 21.7 16.4 51.0 4.0 29.9 24.6 19.4 47.6 4.0 38.1 32.8 27.5 22.3 44.2 4.0 44.0 40.9 35.6 30.3 25.1 41.1 4.0 44.3 41.5 36.2 30.9 25.7 41.7 4.0 22.5 17.0 51.4 4.0 31.0 25.5 20.0 48.0 4.0 39.5 34.0 28.5 23.0 44.5 4.0 44.6 42.3 36.9 31.4 25.9 41.4 4.0 44.8 43.0 37.5 32.0 26.5 42.0 4.0 23.3 17.6 51.8 4.0 32.1 26.4 20.7 48.3 4.0 40.9 35.2 29.4 23.7 44.9 4.0 45.2 43.8 38.1 32.4 26.7 41.7 4.0 45.3 44.4 38.7 33.0 27.3 42.3 4.0 33.0 27.1 21.2 48.3 4.0 42.0 36.1 30.2 24.3 44.8 4.0 45.3 44.7 38.8 33.0 27.1 41.7 4.0 45.4 45.0 39.1 33.3 27.4 42.2 4.0 90 26.5 35.4 44.3 46.7 46.0 27.4 36.6 45.8 46.9 46.1 28.3 37.8 47.2 47.0 46.3 38.5 48.2 47.5 46.7 26.8 34.1 41.4 41.1 41.7 28.3 35.5 42.7 41.4 42.0 29.9 36.9 44.0 41.7 42.3 37.8 44.4 41.7 42.2 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 21.4 16.3 30.3 25.2 20.1 39.2 34.1 29.0 23.9 45.3 41.5 36.4 31.3 45.9 43.5 38.4 33.2 22.1 16.8 31.3 26.0 20.7 40.5 35.2 29.9 24.6 46.2 42.8 37.5 32.2 46.1 44.9 39.6 34.3 22.8 17.3 32.3 26.8 21.3 41.8 36.3 30.8 25.3 47.0 44.1 38.7 33.2 46.3 46.3 40.8 35.3 32.9 27.3 21.7 42.6 36.9 31.3 25.7 47.5 44.9 39.3 33.7 46.7 46.7 41.1 35.5 105°F 20.6 15.3 28.8 23.5 18.1 36.9 31.6 26.3 21.0 40.8 38.1 32.8 27.4 41.3 38.4 33.1 27.8 21.5 15.9 30.0 24.4 18.8 38.4 32.9 27.3 21.7 41.3 39.6 34.0 28.4 41.8 39.9 34.3 28.8 22.3 16.5 31.1 25.3 19.5 39.9 34.1 28.3 22.5 41.7 41.0 35.2 29.4 42.3 41.4 35.6 29.8 31.8 25.8 19.9 40.8 34.8 28.8 22.8 41.7 41.4 35.4 29.4 42.2 41.9 35.9 29.9 65 26.1 28.1 26.9 29.0 27.7 29.8 28.1 29.9 22.1 22.5 22.9 23.2 23.6 24.0 23.4 23.9 31 294604-YTG-G-0511 DEQ048 (4.0 Ton) (Continued) Air on Evaporator Coil CFM 1400 1500 1600 1700 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 48.6 44.7 40.8 37.7 38.7 48.9 45.0 41.1 38.0 39.0 49.3 45.3 41.4 38.3 39.3 45.1 41.2 38.1 39.1 4.5 4.5 4.4 4.4 4.4 4.5 4.5 4.4 4.4 4.4 4.5 4.5 4.4 4.4 4.4 4.5 4.4 4.4 4.5 26.7 33.1 39.5 37.7 38.7 28.7 34.6 40.5 38.0 39.0 30.7 36.1 41.4 38.3 39.3 36.8 41.2 38.1 39.1 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 19.6 14.2 46.1 5.0 27.7 22.3 16.9 41.8 4.9 35.8 30.4 25.1 19.7 37.5 4.8 37.7 35.3 29.9 24.5 19.1 34.4 4.9 38.2 35.4 30.0 24.6 19.2 35.8 4.9 20.5 14.8 46.4 5.0 28.9 23.3 17.6 42.1 4.9 37.4 31.7 26.1 20.4 37.8 4.8 38.0 36.8 31.1 25.5 19.8 34.6 4.9 38.8 36.9 31.2 25.6 19.9 36.0 4.9 21.3 15.4 46.7 5.0 30.1 24.2 18.3 42.4 4.9 38.9 33.0 27.1 21.2 38.0 4.8 38.3 38.3 32.3 26.4 20.5 34.8 4.9 39.3 38.4 32.4 26.5 20.6 36.3 4.9 30.7 24.6 18.5 42.0 5.0 39.7 33.6 27.5 21.4 37.7 4.9 38.1 38.1 32.0 25.9 19.8 34.5 4.9 39.1 38.7 32.6 26.5 20.4 35.9 4.9 90 27.0 32.1 37.5 34.4 35.8 29.7 33.6 37.8 34.6 36.0 32.4 35.2 38.0 34.8 36.3 35.8 37.7 34.5 35.9 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 18.5 13.1 26.6 21.2 15.7 34.7 29.3 23.8 18.4 34.4 32.5 27.1 21.6 35.2 32.3 26.9 21.4 19.4 13.7 27.9 22.2 16.4 36.4 30.6 24.9 19.1 34.6 33.7 28.3 22.5 35.7 33.8 28.1 22.4 20.3 14.3 29.2 23.1 17.1 38.0 32.0 25.9 19.9 34.8 34.8 29.5 23.4 36.3 35.3 29.3 23.3 29.6 23.4 17.2 37.7 32.3 26.1 19.9 34.5 34.5 28.6 22.3 35.9 35.6 29.4 23.1 65 16.2 16.0 16.8 16.6 17.4 17.2 16.1 16.9 1. These capacities are Net Capacities. 2. These ratings include the compressor, condenser fan and supply air blower motors. 32 Johnson Controls Unitary Products 294604-YTG-G-0511 DEQ060 (5.0 Ton) Air on Evaporator Coil CFM 1500 1600 1650 1800 1900 1500 1600 1650 1800 1900 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 76.2 71.6 67.1 59.1 55.5 76.5 71.9 67.3 59.4 55.7 76.7 72.1 67.5 59.5 55.8 77.1 72.5 67.9 59.9 56.2 77.5 72.8 68.1 60.1 56.4 3.8 3.6 3.4 3.5 3.4 3.8 3.6 3.4 3.5 3.5 3.9 3.7 3.5 3.6 3.5 4.0 3.8 3.6 3.7 3.6 4.0 3.8 3.6 3.7 3.7 34.4 44.7 55.1 59.1 55.5 35.8 46.5 57.1 59.4 55.7 36.4 47.3 58.2 59.5 55.8 38.5 49.9 61.3 59.9 56.2 39.9 51.6 63.3 60.1 56.4 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 69.3 63.6 57.9 54.1 51.9 69.3 63.6 58.0 54.1 51.9 69.3 63.7 58.0 54.1 52.0 69.4 63.7 58.0 54.1 52.0 69.4 63.7 58.0 54.1 52.0 4.6 4.6 4.5 4.4 4.4 4.7 4.6 4.5 4.5 4.4 4.7 4.6 4.5 4.5 4.4 4.7 4.6 4.5 4.5 4.5 4.7 4.6 4.5 4.5 4.5 30.3 40.7 51.2 54.1 51.9 31.5 42.2 53.0 54.1 51.9 32.1 43.0 53.9 54.1 52.0 33.8 45.2 56.6 54.1 52.0 35.0 46.7 58.4 54.1 52.0 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 28.1 21.7 72.8 4.2 38.4 32.1 25.8 67.6 4.1 48.8 42.4 36.1 29.8 62.5 3.9 51.8 45.4 39.1 32.8 26.5 56.6 4.0 55.5 51.8 45.5 39.1 32.8 53.7 3.9 29.1 22.4 72.9 4.2 39.8 33.1 26.5 67.8 4.1 50.5 43.8 37.2 30.5 62.6 4.0 54.2 47.0 40.3 33.7 27.0 56.7 4.0 55.7 53.5 46.8 40.2 33.5 53.8 4.0 29.6 22.8 73.0 4.3 40.5 33.7 26.9 67.9 4.1 51.4 44.5 37.7 30.9 62.7 4.0 55.5 47.7 40.9 34.1 27.3 56.8 4.0 55.8 54.3 47.5 40.7 33.9 53.9 4.0 31.2 23.9 73.3 4.3 42.6 35.3 28.0 68.1 4.2 54.0 46.7 39.3 32.0 62.9 4.0 59.2 50.0 42.7 35.3 28.0 57.0 4.1 56.2 56.9 49.6 42.3 35.0 54.1 4.0 32.2 24.6 73.4 4.4 44.0 36.3 28.7 68.2 4.2 55.7 48.1 40.4 32.8 63.1 4.1 61.6 51.5 43.8 36.2 28.5 57.1 4.1 56.4 58.6 51.0 43.3 35.7 54.2 4.1 95°F 24.1 18.0 63.8 5.2 34.6 28.5 22.3 58.4 5.1 45.1 38.9 32.8 26.7 52.9 5.0 51.5 45.4 39.2 33.1 26.9 50.5 4.9 51.9 48.4 42.3 36.1 30.0 49.2 4.9 25.0 18.5 63.9 5.2 35.8 29.3 22.8 58.5 5.1 46.5 40.1 33.6 27.1 53.0 5.0 52.5 46.7 40.2 33.8 27.3 50.6 4.9 51.9 49.8 43.4 36.9 30.4 49.3 4.9 25.4 18.8 64.0 5.2 36.4 29.7 23.1 58.5 5.1 47.3 40.7 34.0 27.4 53.1 5.1 53.1 47.4 40.7 34.1 27.5 50.6 4.9 52.0 50.5 43.9 37.3 30.6 49.3 4.9 26.7 19.6 64.2 5.2 38.1 31.0 23.9 58.7 5.2 49.5 42.4 35.2 28.1 53.2 5.1 54.6 49.4 42.2 35.1 28.0 50.8 5.0 52.0 52.7 45.6 38.4 31.3 49.5 5.0 27.6 20.1 64.3 5.3 39.3 31.8 24.4 58.8 5.2 51.0 43.5 36.1 28.6 53.3 5.1 55.7 50.7 43.2 35.8 28.3 50.9 5.0 52.0 54.1 46.7 39.2 31.7 49.6 5.0 90 32.3 42.7 53.1 56.6 53.7 33.6 44.3 55.1 56.7 53.8 34.2 45.1 56.0 56.8 53.9 36.2 47.6 59.0 57.0 54.1 37.5 49.2 60.9 57.1 54.2 29.7 39.5 49.3 50.5 49.2 31.5 41.0 50.4 50.6 49.3 32.4 41.7 50.9 50.6 49.3 35.2 43.9 52.6 50.8 49.5 37.0 45.4 53.8 50.9 49.6 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 26.1 19.9 36.5 30.3 24.0 46.9 40.7 34.5 28.2 51.6 45.4 39.2 32.9 53.7 50.1 43.9 37.6 27.0 20.5 37.8 31.2 24.7 48.5 42.0 35.4 28.8 53.4 46.8 40.3 33.7 53.8 51.7 45.1 38.5 27.5 20.8 38.4 31.7 25.0 49.3 42.6 35.9 29.2 54.3 47.5 40.8 34.1 53.9 52.4 45.7 39.0 29.0 21.7 40.3 33.1 25.9 51.7 44.5 37.3 30.1 56.9 49.7 42.4 35.2 54.1 54.8 47.6 40.4 29.9 22.4 41.6 34.1 26.5 53.3 45.8 38.2 30.7 58.6 51.1 43.5 36.0 54.2 56.4 48.8 41.3 105°F 23.6 17.6 33.4 27.3 21.2 43.2 37.1 31.0 24.9 49.2 43.6 37.5 31.4 49.2 46.0 39.9 33.8 24.5 18.1 34.6 28.1 21.7 44.6 38.2 31.8 25.4 49.8 44.9 38.5 32.1 49.3 47.4 41.0 34.6 24.9 18.4 35.1 28.5 22.0 45.3 38.7 32.2 25.6 50.1 45.6 39.0 32.4 49.3 48.1 41.5 34.9 26.2 19.1 36.8 29.8 22.7 47.5 40.4 33.3 26.3 51.1 47.5 40.4 33.4 49.5 50.1 43.1 36.0 27.1 19.7 38.0 30.6 23.2 48.9 41.5 34.1 26.7 51.7 48.8 41.4 34.0 49.6 51.5 44.1 36.7 65 26.7 31.4 27.1 32.0 27.4 32.3 28.0 33.1 28.4 33.7 25.4 27.8 25.7 28.2 25.8 28.3 26.3 28.9 26.7 29.3 33 294604-YTG-G-0511 DEQ060 (5.0 Ton) (Continued) Air on Evaporator Coil CFM 1500 1600 1650 1800 1900 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 58.3 53.1 47.9 46.9 46.5 58.6 53.3 48.1 47.1 46.6 58.7 53.4 48.2 47.2 46.7 59.0 53.8 48.5 47.5 47.0 59.2 54.0 48.7 47.7 47.2 5.7 5.6 5.6 5.4 5.4 5.7 5.7 5.6 5.4 5.4 5.7 5.7 5.6 5.4 5.4 5.7 5.7 5.7 5.4 5.4 5.8 5.7 5.7 5.5 5.5 29.2 38.2 47.3 46.9 46.5 31.6 39.7 47.7 47.1 46.6 32.8 40.4 48.0 47.2 46.7 36.5 42.6 48.6 47.5 47.0 38.9 44.0 49.1 47.7 47.2 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 23.2 17.1 52.8 6.2 32.2 26.2 20.2 47.9 6.2 41.3 35.2 29.2 23.2 42.9 6.1 46.9 41.9 35.8 29.8 23.8 43.4 5.8 46.5 43.6 37.6 31.5 25.5 43.7 5.8 24.0 17.7 53.2 6.2 33.3 27.0 20.6 48.2 6.2 42.7 36.3 30.0 23.6 43.2 6.2 47.1 43.1 36.8 30.4 24.1 43.6 5.9 46.6 44.9 38.6 32.2 25.9 44.0 5.9 24.4 17.9 53.3 6.2 33.9 27.4 20.9 48.3 6.2 43.4 36.8 30.3 23.8 43.4 6.2 47.2 43.8 37.2 30.7 24.2 43.8 5.9 46.7 45.6 39.1 32.6 26.1 44.1 5.9 25.7 18.7 53.8 6.3 35.6 28.6 21.6 48.8 6.2 45.4 38.4 31.4 24.5 43.8 6.2 47.5 45.7 38.7 31.7 24.7 44.2 5.9 47.0 47.6 40.6 33.6 26.6 44.5 5.9 26.5 19.2 54.2 6.3 36.7 29.4 22.0 49.1 6.3 46.8 39.5 32.2 24.9 44.0 6.3 47.7 46.9 39.6 32.3 25.0 44.4 6.0 47.2 48.9 41.6 34.3 26.9 44.8 6.0 90 31.1 37.0 42.9 43.4 43.7 33.6 38.4 43.2 43.6 44.0 34.9 39.1 43.4 43.8 44.1 38.7 41.2 43.8 44.2 44.5 41.2 42.6 44.0 44.4 44.8 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 22.7 16.7 31.0 25.0 19.1 39.4 33.4 27.4 21.4 43.4 40.1 34.1 28.1 43.7 41.2 35.2 29.3 23.5 17.2 32.1 25.8 19.5 40.7 34.4 28.1 21.8 43.6 41.3 35.0 28.8 44.0 42.5 36.2 29.9 23.9 17.5 32.7 26.2 19.7 41.4 34.9 28.5 22.0 43.8 42.0 35.5 29.1 44.1 43.1 36.7 30.2 25.2 18.2 34.3 27.4 20.4 43.4 36.5 29.5 22.6 44.2 43.8 36.9 30.0 44.5 45.0 38.1 31.2 26.0 18.8 35.4 28.1 20.9 44.7 37.5 30.3 23.0 44.4 45.0 37.8 30.6 44.8 46.3 39.0 31.8 65 22.2 23.3 22.5 23.6 22.6 23.8 23.0 24.2 23.3 24.6 1. These capacities are Net Capacities. 2. These ratings include the compressor, condenser fan and supply air blower motors. 34 Johnson Controls Unitary Products 294604-YTG-G-0511 DEX024-048 Cooling Capacities DEX024 (2.0 Ton) Air on Evaporator Coil CFM 600 800 600 800 600 800 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 21.5 21.3 21.2 20.2 19.4 30.1 28.4 26.7 24.0 24.4 1.1 1.1 1.1 1.1 1.1 1.6 1.6 1.5 1.5 1.5 7.5 14.3 21.2 20.2 19.4 13.1 19.9 26.7 24.0 24.4 77 72 67 62 57 77 72 67 62 57 21.8 20.0 18.3 16.6 17.0 27.8 25.5 23.2 21.4 21.6 1.4 1.4 1.4 1.4 1.4 2.0 1.9 1.9 1.9 1.8 12.1 15.2 18.3 16.6 17.0 14.7 18.9 23.2 21.4 21.6 77 72 67 62 57 77 72 67 62 57 18.7 16.8 15.0 14.2 14.1 23.7 21.7 19.6 18.4 18.3 1.8 1.8 1.8 1.8 1.8 2.5 2.4 2.3 2.3 2.3 13.2 14.1 15.0 14.2 14.1 15.7 17.6 19.6 18.4 18.3 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 7.8 6.8 21.6 1.3 12.7 11.0 9.3 20.7 1.3 17.6 15.2 12.9 10.6 19.7 1.3 20.2 19.9 15.6 11.4 7.1 18.4 1.3 19.4 19.4 15.1 10.9 6.6 18.2 1.3 12.3 10.2 28.9 1.8 17.3 14.8 12.2 26.9 1.8 22.4 19.3 16.2 13.1 24.9 1.7 24.0 24.0 20.6 17.1 13.7 22.7 1.7 24.4 24.4 20.8 17.3 13.7 23.0 1.7 95°F 8.8 7.0 20.2 1.6 13.0 10.7 8.4 18.4 1.6 17.1 14.3 11.6 8.8 16.6 1.6 16.6 16.6 12.4 8.2 3.9 15.4 1.6 17.0 17.0 12.7 8.3 4.0 15.5 1.6 11.2 9.0 25.8 2.3 16.2 13.4 10.7 23.6 2.2 21.2 17.9 14.6 11.3 21.4 2.2 21.4 21.4 17.9 14.4 10.9 19.9 2.1 21.6 21.6 18.1 14.6 11.1 20.0 2.1 115°F 8.5 6.0 11.8 9.4 7.1 15.0 12.9 9.0 5.1 14.2 14.2 10.1 6.0 1.9 14.1 14.1 11.3 8.4 5.6 10.1 7.6 14.8 11.9 9.1 19.5 16.2 13.0 9.7 18.4 18.4 15.0 11.5 8.0 18.3 18.3 14.8 11.3 7.8 90 9.8 14.8 19.7 18.4 18.2 13.9 19.4 24.9 22.7 23.0 12.7 14.7 16.6 15.4 15.5 15.2 18.3 21.4 19.9 20.0 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 8.3 6.9 12.8 10.8 8.9 17.3 14.8 12.2 9.7 18.4 18.3 14.0 9.8 18.2 18.2 13.9 9.6 11.7 9.6 16.8 14.1 11.4 21.8 18.6 15.4 12.2 22.7 22.7 19.2 15.7 23.0 23.0 19.5 15.9 105°F 8.7 6.5 12.4 10.1 7.8 16.0 13.6 10.3 6.9 15.4 15.4 11.2 7.1 15.5 15.5 12.0 8.4 10.6 8.3 15.5 12.7 9.9 20.4 17.1 13.8 10.5 19.9 19.9 16.4 12.9 20.0 20.0 16.5 13.0 65 5.5 5.3 12.3 12.4 2.9 4.8 9.4 9.5 1. These capacities are Net Capacities. 2. These ratings include the compressor, condenser fan and supply air blower motors. Johnson Controls Unitary Products 35 294604-YTG-G-0511 DEX030 (2.5 Ton) Air on Evaporator Coil CFM 675 1000 675 1000 675 1000 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 29.5 27.2 25.0 22.8 20.1 37.4 36.3 35.3 31.0 30.5 1.3 1.3 1.3 1.4 1.4 2.1 2.1 2.1 1.9 1.9 14.1 18.6 23.0 22.8 20.1 16.7 24.7 32.7 31.0 30.5 77 72 67 62 57 77 72 67 62 57 26.3 24.2 22.0 20.2 19.9 37.1 32.9 28.6 27.5 27.3 1.7 1.7 1.7 1.7 1.7 2.7 2.5 2.3 2.4 2.4 12.6 17.3 21.9 20.2 19.9 18.1 23.4 28.6 27.5 27.3 77 72 67 62 57 77 72 67 62 57 22.3 20.3 18.3 16.5 16.8 30.8 28.2 25.6 23.8 23.7 2.2 2.2 2.2 2.2 2.2 3.1 3.1 3.0 2.9 2.9 12.8 15.5 18.3 16.5 16.8 17.4 21.5 25.6 23.8 23.7 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 12.0 9.9 27.9 1.5 16.2 13.7 11.3 25.7 1.5 20.3 17.5 14.8 12.0 23.5 1.5 22.8 21.4 17.3 13.3 9.2 21.5 1.5 20.1 20.3 15.8 11.2 6.6 20.0 1.5 14.7 12.0 37.2 2.3 21.5 18.3 15.1 34.6 2.2 28.3 24.5 20.8 17.0 32.0 2.2 31.0 28.8 24.8 20.7 16.6 29.2 2.1 30.5 30.5 26.3 22.1 17.9 28.9 2.1 95°F 10.6 8.6 24.3 2.0 14.8 12.4 10.0 22.2 2.0 19.1 16.2 13.4 10.6 20.2 2.0 20.2 20.0 15.7 11.5 7.3 18.3 2.0 19.9 20.2 15.9 11.6 7.4 18.3 2.0 14.7 12.0 34.0 2.9 20.1 16.9 13.7 30.5 2.8 25.5 21.8 18.0 14.3 27.1 2.7 27.5 27.1 23.0 18.9 14.8 25.6 2.7 27.3 27.2 23.1 18.9 14.8 25.5 2.7 115°F 8.1 7.1 13.2 10.8 8.5 18.3 14.6 10.8 7.1 16.5 16.7 12.5 8.4 4.2 16.8 17.0 13.8 10.6 7.4 12.5 9.8 18.3 15.1 11.9 24.1 20.4 16.7 12.9 23.8 23.7 19.7 15.6 11.5 23.7 23.7 19.6 15.5 11.4 90 13.4 17.9 22.5 21.5 20.0 17.4 24.0 30.7 29.2 28.9 12.7 16.4 20.1 18.3 18.3 17.7 22.4 27.1 25.6 25.5 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 11.3 9.2 15.5 13.1 10.6 19.7 16.9 14.1 11.3 21.5 20.7 16.5 12.4 20.0 20.2 15.8 11.4 14.7 12.0 20.8 17.6 14.4 26.9 23.2 19.4 15.7 29.2 28.0 23.9 19.8 28.9 28.8 24.7 20.5 105°F 9.3 7.8 14.0 11.6 9.2 18.7 15.4 12.1 8.8 18.3 18.3 14.1 10.0 18.3 18.6 14.9 11.1 13.6 10.9 19.2 16.0 12.8 24.8 21.1 17.4 13.6 25.6 25.4 21.3 17.3 25.5 25.4 21.3 17.2 65 8.3 7.0 15.7 16.3 5.8 7.4 13.2 13.1 1. These capacities are Net Capacities. 2. These ratings include the compressor, condenser fan and supply air blower motors. 36 Johnson Controls Unitary Products 294604-YTG-G-0511 DEX036 (3.0 Ton) Air on Evaporator Coil CFM 800 1150 800 1150 800 1150 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 36.6 31.9 27.2 26.6 23.8 48.0 44.5 41.1 37.5 37.6 1.5 1.5 1.5 1.5 1.5 2.4 2.4 2.4 2.3 2.3 17.4 21.9 26.5 26.6 23.8 23.1 30.7 38.3 37.5 37.6 77 72 67 62 57 77 72 67 62 57 31.4 28.4 25.4 23.5 23.5 44.2 40.1 36.0 33.9 33.7 1.9 1.9 1.9 1.9 1.9 3.2 3.1 2.9 2.9 2.9 16.9 21.2 25.4 23.5 23.5 21.3 28.6 36.0 33.9 33.7 77 72 67 62 57 77 72 67 62 57 26.1 23.8 21.6 19.8 20.3 38.0 34.8 31.6 29.2 29.6 2.4 2.4 2.4 2.4 2.4 3.8 3.8 3.7 3.6 3.6 16.2 18.9 21.6 19.8 20.3 21.2 26.4 31.6 29.2 29.6 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 15.3 12.6 34.0 1.7 18.9 15.9 12.9 30.1 1.7 22.6 19.2 15.7 12.3 26.3 1.7 26.6 25.4 21.2 17.0 12.8 25.1 1.7 23.8 24.0 19.8 15.5 11.2 23.6 1.7 19.5 15.9 46.1 2.7 26.6 22.5 18.4 42.3 2.7 33.7 29.1 24.5 19.9 38.5 2.6 37.5 36.4 31.4 26.4 21.4 35.7 2.5 37.6 37.8 32.6 27.4 22.3 35.7 2.5 95°F 13.6 10.7 28.7 2.2 18.0 14.9 11.8 26.1 2.2 22.5 19.1 15.7 12.3 23.5 2.2 23.5 23.1 19.0 14.9 10.8 21.6 2.2 23.5 23.2 19.0 14.9 10.7 21.9 2.2 17.8 14.3 41.1 3.4 24.6 20.6 16.5 37.4 3.3 31.4 26.8 22.3 17.7 33.8 3.2 33.9 32.9 28.0 23.0 18.0 31.5 3.2 33.7 33.5 28.5 23.4 18.3 31.7 3.1 115°F 10.5 8.3 15.8 12.8 9.8 21.2 17.3 13.5 9.6 19.8 19.8 15.7 11.6 7.6 20.3 20.1 16.5 12.9 9.3 15.2 11.7 22.4 18.3 14.3 29.6 25.0 20.5 15.9 29.2 29.2 24.4 19.7 14.9 29.6 29.5 24.7 19.8 15.0 90 17.2 21.6 25.9 25.1 23.6 22.2 29.7 37.1 35.7 35.7 16.5 20.0 23.5 21.6 21.9 21.3 27.5 33.8 31.5 31.7 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 14.4 11.7 18.5 15.4 12.3 22.5 19.1 15.7 12.3 25.1 24.2 20.1 15.9 23.6 23.6 19.4 15.2 18.7 15.1 25.6 21.5 17.5 32.6 28.0 23.4 18.8 35.7 34.7 29.7 24.7 35.7 35.7 30.5 25.4 105°F 12.0 9.5 16.9 13.9 10.8 21.9 18.2 14.6 11.0 21.6 21.4 17.3 13.3 21.9 21.7 17.8 13.9 16.5 13.0 23.5 19.4 15.4 30.5 25.9 21.4 16.8 31.5 31.1 26.2 21.3 31.7 31.5 26.6 21.6 65 11.8 11.0 19.7 20.3 9.2 10.0 16.5 16.6 1. These capacities are Net Capacities. 2. These ratings include the compressor, condenser fan and supply air blower motors. Johnson Controls Unitary Products 37 294604-YTG-G-0511 DEX042 (3.5 Ton) Air on Evaporator Coil CFM 925 1400 925 1400 925 1400 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 40.2 37.1 34.0 30.5 29.4 61.7 55.5 49.4 44.5 46.0 1.9 1.9 1.9 1.9 1.8 3.4 3.1 3.1 3.0 2.9 21.0 26.3 31.6 30.5 29.4 29.1 37.9 46.7 44.5 46.0 77 72 67 62 57 77 72 67 62 57 34.4 31.8 29.2 25.7 25.6 51.7 47.6 43.5 39.2 39.8 2.4 2.3 2.3 2.4 2.4 3.8 3.7 3.5 3.5 3.5 17.5 23.3 29.1 25.7 25.6 25.3 34.3 43.3 39.2 39.8 77 72 67 62 57 77 72 67 62 57 28.9 26.2 23.4 21.3 21.5 43.2 39.4 35.6 33.2 33.6 2.9 2.9 2.9 2.9 2.9 4.5 4.4 4.3 4.2 4.2 17.9 20.6 23.4 21.3 21.5 24.6 30.1 35.6 33.2 33.6 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 17.4 13.7 37.3 2.2 22.4 18.5 14.7 34.5 2.1 27.5 23.3 19.2 15.1 31.6 2.1 30.5 27.7 23.2 18.8 14.3 28.1 2.1 29.4 29.4 24.8 20.1 15.5 27.5 2.1 24.8 20.4 56.7 3.3 32.7 27.6 22.4 51.6 3.3 40.7 34.7 28.8 22.8 46.5 3.3 44.5 42.4 36.2 30.1 23.9 41.8 3.2 46.0 45.5 39.2 32.8 26.4 42.9 3.1 95°F 14.0 10.6 31.7 2.6 19.5 15.7 11.9 29.0 2.6 24.9 20.8 16.7 12.6 26.3 2.6 25.7 25.3 20.9 16.5 12.1 23.5 2.6 25.6 25.6 21.0 16.5 11.9 23.6 2.7 20.8 16.3 47.4 4.1 29.2 24.1 19.0 43.5 4.0 37.6 31.9 26.2 20.5 39.5 3.9 39.2 39.2 33.0 26.8 20.7 36.2 3.8 39.8 39.8 33.6 27.4 21.2 36.7 3.8 115°F 11.5 8.6 17.1 13.5 9.9 22.6 18.4 14.3 10.1 21.3 21.3 16.9 12.6 8.2 21.5 21.4 17.2 13.0 8.8 16.5 12.6 25.4 20.7 16.0 34.2 28.7 23.3 17.8 33.2 33.3 27.2 21.2 15.2 33.6 33.8 27.8 21.9 15.9 90 19.2 24.8 30.3 28.1 27.5 27.2 36.1 45.0 41.8 42.9 17.7 21.9 26.2 23.5 23.6 24.9 32.2 39.4 36.2 36.7 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 15.7 12.2 20.9 17.1 13.3 26.2 22.1 18.0 13.8 28.1 26.5 22.0 17.6 27.5 27.5 22.9 18.3 22.8 18.4 31.0 25.8 20.7 39.1 33.3 27.5 21.7 41.8 40.8 34.6 28.4 42.9 42.7 36.4 30.1 105°F 12.8 9.6 18.3 14.6 10.9 23.8 19.6 15.5 11.4 23.5 23.3 18.9 14.5 23.6 23.5 19.1 14.7 18.7 14.5 27.3 22.4 17.5 35.9 30.3 24.7 19.1 36.2 36.2 30.1 24.0 36.7 36.8 30.7 24.6 65 13.2 13.7 22.3 23.8 10.1 10.4 17.9 18.5 1. These capacities are Net Capacities. 2. These ratings include the compressor, condenser fan and supply air blower motors. 38 Johnson Controls Unitary Products 294604-YTG-G-0511 DEX048 (4.0 Ton) Air on Evaporator Coil CFM 1050 1600 1050 1600 1050 1600 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 47.3 43.7 40.1 35.9 35.5 66.0 61.0 56.0 51.7 50.8 2.2 2.1 2.1 2.1 2.1 3.6 3.5 3.4 3.3 3.2 23.6 30.5 37.3 35.9 35.5 30.9 42.4 53.9 51.7 50.8 77 72 67 62 57 77 72 67 62 57 42.1 38.5 35.0 31.8 31.3 58.1 53.6 49.0 45.6 44.9 2.7 2.7 2.7 2.7 2.7 4.2 4.1 4.0 3.9 3.9 21.6 28.3 35.0 31.8 31.3 29.0 39.0 49.0 45.6 44.9 77 72 67 62 57 77 72 67 62 57 34.3 31.6 28.9 26.4 26.7 48.7 44.4 40.2 37.7 37.9 3.4 3.4 3.3 3.3 3.3 4.9 4.8 4.8 4.6 4.6 22.6 25.7 28.9 26.4 26.7 31.7 36.0 40.2 37.7 37.9 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 19.9 16.0 44.7 2.4 26.1 21.8 17.5 41.1 2.4 32.3 27.6 22.9 18.1 37.5 2.4 35.9 33.2 28.9 24.6 20.3 33.8 2.4 35.5 35.5 30.9 26.3 21.6 33.4 2.4 26.5 21.0 62.1 3.8 36.3 30.1 24.0 57.3 3.7 46.0 39.2 32.4 25.7 52.5 3.6 51.7 48.9 41.6 34.2 26.8 48.7 3.5 50.8 50.7 43.0 35.4 27.7 47.8 3.5 95°F 17.3 13.2 38.2 3.1 23.8 19.4 14.9 35.1 3.0 30.4 25.6 20.7 15.9 31.9 3.0 31.8 30.9 26.4 22.0 17.5 29.1 3.0 31.3 31.3 26.8 22.2 17.7 29.0 3.0 22.5 17.1 53.4 4.5 32.9 26.8 20.7 49.0 4.4 43.4 36.5 29.7 22.9 44.6 4.3 45.6 45.5 38.0 30.5 23.0 41.6 4.2 44.9 44.8 37.4 29.9 22.4 41.4 4.2 115°F 15.4 10.8 21.3 16.9 12.6 27.2 23.1 18.9 14.7 26.4 26.4 22.0 17.5 13.0 26.7 26.7 21.6 16.5 11.4 19.6 14.4 29.9 23.8 17.8 40.2 33.3 26.4 19.5 37.7 37.7 30.2 22.8 15.3 37.9 37.9 30.6 23.4 16.2 90 22.6 29.4 36.1 33.8 33.4 29.9 40.7 51.5 48.7 47.8 22.1 27.0 31.9 29.1 29.0 30.3 37.5 44.6 41.6 41.4 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 18.6 14.6 25.0 20.6 16.2 31.4 26.6 21.8 17.0 33.8 32.1 27.7 23.3 33.4 33.4 28.8 24.2 24.5 19.1 34.6 28.5 22.3 44.7 37.9 31.1 24.3 48.7 47.2 39.8 32.4 47.8 47.7 40.2 32.6 105°F 16.4 12.0 22.6 18.2 13.7 28.8 24.3 19.8 15.3 29.1 28.7 24.2 19.7 29.0 29.0 24.2 19.4 21.0 15.7 31.4 25.3 19.3 41.8 34.9 28.1 21.2 41.6 41.6 34.1 26.6 41.4 41.3 34.0 26.7 65 18.9 19.7 24.9 25.1 15.3 14.6 19.2 19.3 1. These capacities are Net Capacities. 2. These ratings include the compressor, condenser fan and supply air blower motors. Johnson Controls Unitary Products 39 294604-YTG-G-0511 DEY060 Cooling Capacities DEY060 (5.0 Ton) Air on Evaporator Coil CFM 1150 1750 1150 1750 1150 1750 WB (°F) Net Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 58.8 53.4 47.9 45.5 44.6 73.6 69.7 65.8 61.0 58.9 2.7 2.7 2.8 2.7 2.7 4.5 4.2 4.0 4.0 3.9 27.2 33.7 40.3 45.5 44.6 30.7 44.0 57.4 61.0 58.9 77 72 67 62 57 77 72 67 62 57 51.8 47.1 42.5 40.3 38.9 71.9 65.2 58.5 53.3 54.0 3.5 3.4 3.4 3.4 3.4 5.1 5.1 5.1 4.8 4.8 23.5 31.5 39.5 40.3 38.9 33.0 43.7 54.5 53.3 54.0 77 72 67 62 57 77 72 67 62 57 45.1 41.6 38.1 34.8 34.1 61.9 56.3 50.7 46.2 47.9 4.3 4.3 4.3 4.3 4.3 6.2 6.1 6.0 5.8 5.8 23.6 29.6 35.6 34.8 34.1 30.2 40.4 50.7 46.2 47.9 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Net Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 22.9 18.6 55.3 3.1 29.3 24.9 20.5 50.3 3.1 35.8 31.3 26.8 22.4 45.2 3.1 44.0 39.0 34.6 30.2 25.8 42.9 3.1 44.6 42.8 38.3 33.8 29.4 41.8 3.1 26.7 22.7 72.7 4.9 38.8 33.5 28.2 67.4 4.8 50.9 44.3 37.8 31.3 62.1 4.6 61.0 54.7 47.2 39.6 32.0 57.1 4.5 58.9 58.2 50.7 43.3 35.8 56.4 4.5 95°F 19.9 16.3 48.4 3.9 27.2 22.8 18.4 44.4 3.9 34.4 29.3 24.2 19.0 40.3 3.9 40.3 36.6 32.3 27.9 23.6 37.6 3.9 38.9 37.7 33.2 28.6 24.1 36.5 3.8 27.3 21.6 66.9 5.8 37.5 31.3 25.1 60.7 5.7 47.7 41.0 34.2 27.5 54.6 5.7 53.3 49.6 42.7 35.7 28.7 49.7 5.5 54.0 53.0 45.2 37.5 29.8 50.9 5.5 115°F 18.7 13.8 25.1 20.6 16.2 31.6 27.5 23.4 19.4 34.8 33.7 29.3 25.0 20.7 34.1 33.0 27.5 22.1 16.7 23.6 18.0 34.2 28.0 21.8 44.8 38.0 31.1 24.3 46.2 46.2 38.8 31.3 23.9 47.9 46.7 39.1 31.5 23.9 90 25.4 32.6 39.9 42.9 41.8 31.8 43.9 55.9 57.1 56.4 23.6 30.6 37.6 37.6 36.5 31.6 42.1 52.6 49.7 50.9 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 21.4 17.4 28.2 23.9 19.5 35.1 30.3 25.5 20.7 42.2 37.8 33.4 29.1 41.8 40.3 35.7 31.2 27.0 22.1 38.1 32.4 26.6 49.3 42.6 36.0 29.4 57.1 52.2 44.9 37.6 56.4 55.6 48.0 40.4 105°F 19.3 15.0 26.1 21.7 17.3 33.0 28.4 23.8 19.2 37.6 35.1 30.8 26.5 36.5 35.3 30.4 25.4 25.4 19.8 35.9 29.6 23.4 46.3 39.5 32.7 25.9 49.7 47.9 40.7 33.5 50.9 49.9 42.2 34.5 65 24.7 26.7 30.3 32.8 22.1 20.4 26.3 26.8 1. These capacities are Net Capacities. 2. These ratings include the compressor, condenser fan and supply air blower motors. 40 Johnson Controls Unitary Products 294604-YTG-G-0511 Airflow Performance Side Duct Application DEY/DEX024-060 Size (Tons) Model Mode Low Cool 024 (2.0) DEX High Heat Low Cool 030 (2.5) DEX High Heat Low Cool 036 (3.0) DEX High Heat Low Cool 042 (3.5) DEX High Heat Low Cool 048 (4.0) DEX High Heat Low Cool 060 (5.0) DEY High Heat Thermostat Input Speed Tap CFM Y1 Y1 Y1 Y1 Y1+Y2 Y1+Y2 Y1+Y2 Y1+Y2 W1 W1 W1 Y1 Y1 Y1 Y1 Y1+Y2 Y1+Y2 Y1+Y2 Y1+Y2 W1 W1 W1 W1 Y1 Y1 Y1 Y1 Y1+Y2 Y1+Y2 Y1+Y2 Y1+Y2 W1 W1 W1 W1 Y1 Y1 Y1 Y1 Y1+Y2 Y1+Y2 Y1+Y2 Y1+Y2 W1 W1 W1 W1 Y1 Y1 Y1 Y1 Y1+Y2 Y1+Y2 Y1+Y2 Y1+Y2 W1 W1 W1 W1 Y1 Y1 Y1 Y1 Y1+Y2 Y1+Y2 Y1+Y2 Y1+Y2 W1 W1 W1 W1 COOL-A COOL-B COOL-C COOL-D COOL-A COOL-B COOL-C COOL-D HEAT-A HEAT-B HEAT-C COOL-A COOL-B COOL-C COOL-D COOL-A COOL-B COOL-C COOL-D HEAT-A HEAT-B HEAT-C HEAT-D COOL-A COOL-B COOL-C COOL-D COOL-A COOL-B COOL-C COOL-D HEAT-A HEAT-B HEAT-C HEAT-D COOL-A COOL-B COOL-C COOL-D COOL-A COOL-B COOL-C COOL-D HEAT-A HEAT-B HEAT-C HEAT-D COOL-A COOL-B COOL-C COOL-D COOL-A COOL-B COOL-C COOL-D HEAT-A HEAT-B HEAT-C HEAT-D COOL-A COOL-B COOL-C COOL-D COOL-A COOL-B COOL-C COOL-D HEAT-A HEAT-B HEAT-C HEAT-D 600 450 525 675 800 600 700 900 800 720 880 670 620 720 770 1000 925 1075 1150 1000 900 1100 1000 900 750 830 980 1200 1000 1100 1300 1200 1080 1275 1200 920 790 850 980 1400 1200 1300 1500 1225 1100 1350 1225 1050 920 980 1120 1600 1400 1500 1700 1600 1440 1760 1600 1170 1110 1210 1270 1750 1650 1800 1900 1900 1975 2150 2070 Johnson Controls Unitary Products External Static Pressure (Inch Water Gauge) 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Watts Watts Watts Watts Watts Watts Watts Watts Watts 57 74 91 108 126 143 161 179 197 39 54 69 84 100 117 134 152 171 47 63 79 95 112 129 146 164 182 71 88 106 124 142 161 179 198 216 99 117 137 156 176 196 217 237 258 57 74 91 108 126 143 161 179 197 76 94 112 130 148 167 186 205 224 126 146 166 187 208 231 253 277 300 99 117 137 156 80 98 116 135 120 140 160 180 61 78 95 113 130 148 166 184 201 54 70 87 104 121 138 156 173 191 70 88 106 124 142 160 178 197 215 81 99 118 136 155 174 193 213 232 159 179 200 222 246 270 296 323 350 129 148 169 190 211 233 256 280 304 194 214 236 260 285 312 341 371 403 233 254 277 302 330 360 392 427 463 159 179 200 222 120 139 159 180 206 227 249 274 159 179 200 222 120 139 159 180 201 222 244 267 291 76 94 113 131 150 168 187 206 225 97 116 135 155 174 194 215 236 256 150 170 191 213 236 260 285 311 337 261 283 306 333 362 394 429 467 507 159 179 200 222 246 270 296 323 350 206 227 249 274 300 328 357 389 422 325 346 372 401 434 471 511 556 604 261 283 306 333 196 217 239 263 308 330 355 383 261 283 306 333 139 166 195 224 255 286 319 352 386 100 124 149 176 205 235 266 299 333 117 143 170 198 227 257 289 322 356 159 188 218 249 281 313 346 379 414 338 383 426 468 509 549 589 627 664 245 281 318 354 390 426 462 497 533 290 330 370 409 447 485 523 560 596 391 439 486 532 576 618 660 700 739 256 293 330 367 203 237 270 304 314 356 397 438 256 293 330 367 184 216 248 280 313 346 380 414 449 139 166 195 224 255 286 319 352 386 159 188 218 249 281 313 346 379 414 211 245 279 313 348 382 417 452 486 448 500 551 600 647 693 736 779 819 338 383 426 468 509 549 589 627 664 391 439 486 532 576 618 660 700 739 508 565 620 672 723 772 818 863 905 448 500 551 600 647 359 405 449 493 535 546 606 663 718 771 448 500 551 600 647 235 283 328 368 404 435 463 485 505 205 258 304 345 381 410 434 451 465 255 301 344 384 420 454 483 509 533 286 329 371 410 448 483 516 547 576 559 608 658 710 762 815 870 925 981 498 542 588 634 683 732 783 835 888 590 643 696 750 805 860 916 973 1030 654 715 775 836 895 955 1013 1072 654 715 775 836 895 703 772 839 904 968 823 913 999 1079 1154 767 847 923 997 1066 - 41 294604-YTG-G-0511 DEQ024-060 Size (Tons) Model Thermostat Input Speed Tap CFM Y1 Y1 Y1 Y1 W1 W1 W1 Y1 Y1 Y1 Y1 W1 W1 W1 W1 Y1 Y1 Y1 Y1 W1 W1 W1 W1 Y1 Y1 Y1 Y1 W1 W1 W1 W1 Y1 Y1 Y1 Y1 W1 W1 W1 W1 Y1 Y1 Y1 Y1 W1 W1 W1 W1 COOL-A COOL-B COOL-C COOL-D HEAT-A HEAT-B HEAT-C COOL-A COOL-B COOL-C COOL-D HEAT-A HEAT-B HEAT-C HEAT-D COOL-A COOL-B COOL-C COOL-D HEAT-A HEAT-B HEAT-C HEAT-D COOL-A COOL-B COOL-C COOL-D HEAT-A HEAT-B HEAT-C HEAT-D COOL-A COOL-B COOL-C COOL-D HEAT-A HEAT-B HEAT-C HEAT-D COOL-A COOL-B COOL-C COOL-D HEAT-A HEAT-B HEAT-C HEAT-D 800 600 700 900 800 720 880 1000 925 1075 1150 1000 900 1100 1000 1200 1000 1100 1300 1200 1080 1275 1200 1400 1200 1300 1500 1225 1100 1350 1225 1600 1400 1500 1700 1600 1440 1760 1600 1500 1650 1800 1900 1900 1975 2150 2070 Unit Speed 0.2 W 87 97 131 170 110 153 214 269 168 215 255 301 354 221 299 376 466 - Mode Cool 024 (2.0) DEQ Heat Cool 030 (2.5) DEQ Heat Cool 036 (3.0) DEQ Heat Cool 042 (3.5) DEQ Heat Cool 048 (4.0) DEQ Heat Cool 060 (5.0) DEQ Heat External Static Pressure (Inch Water Gauge) 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Watts Watts Watts Watts Watts Watts Watts Watts Watts 99 117 137 156 176 196 217 237 258 57 74 91 108 126 143 161 179 197 76 94 112 130 148 167 186 205 224 126 146 166 187 208 231 253 277 300 99 117 137 156 80 98 116 135 120 140 160 180 159 179 200 222 246 270 296 323 350 129 148 169 190 211 233 256 280 304 194 214 236 260 285 312 341 371 403 233 254 277 302 330 360 392 427 463 159 179 200 222 120 139 159 180 206 227 249 274 159 179 200 222 261 283 306 333 362 394 429 467 507 159 179 200 222 246 270 296 323 350 206 227 249 274 300 328 357 389 422 325 346 372 401 434 471 511 556 604 261 283 306 333 196 217 239 263 308 330 355 383 261 283 306 333 338 383 426 468 509 549 589 627 664 245 281 318 354 390 426 462 497 533 290 330 370 409 447 485 523 560 596 391 439 486 532 576 618 660 700 739 256 293 330 367 203 237 270 304 314 356 397 438 256 293 330 367 408 461 512 562 610 657 703 747 790 290 334 378 422 465 508 550 592 633 349 397 445 492 537 582 626 669 711 467 524 579 632 683 732 779 825 868 408 461 512 562 610 657 313 359 405 450 494 537 503 562 619 674 726 777 408 461 512 562 610 657 404 438 475 512 555 597 644 692 728 498 542 588 634 683 732 783 835 888 590 643 696 750 805 860 916 973 1030 654 715 775 836 895 955 1013 1072 654 715 775 836 895 703 772 839 904 968 823 913 999 1079 1154 767 847 923 997 1066 - DEZ024-060 Size (Tons) Model 024 (2.0) DEZ 030 (2.5) DEZ 036 (3.0) DEZ 042 (3.5) DEZ 42 Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) SCFM 726 768 883 990 828 953 1091 1189 966 1148 1258 1361 1458 1241 1406 1536 1656 - RPM 632 651 704 755 673 735 807 861 771 763 766 778 797 702 759 808 858 - SCFM 629 679 812 934 759 894 1041 1144 1235 890 1062 1167 1267 1362 1151 1325 1461 1584 1687 External Static Pressure (Inch Water Gauge) 0.4 0.6 0.8 W RPM SCFM W RPM SCFM W 99 739 110 754 147 797 736 162 889 651 177 187 839 868 202 920 791 216 985 245 952 913 257 125 771 172 823 824 189 909 234 883 983 253 958 910 269 288 927 1091 305 994 1027 318 347 970 1186 360 1028 1125 368 186 860 237 841 975 259 918 278 839 1075 301 911 980 325 325 845 1170 349 913 1070 372 379 859 1262 402 923 1156 423 245 778 1058 268 853 324 826 1242 349 893 1158 373 403 869 1384 427 928 1305 449 492 912 1509 515 966 1430 533 590 955 1611 610 1004 1527 620 RPM 979 1000 1022 1033 1061 1086 983 981 986 959 988 1019 1051 SCFM 696 813 785 912 1007 964 1040 1072 1223 1344 1428 1.0 W 227 261 273 316 352 393 436 396 468 542 615 RPM 1078 1090 1106 1132 1147 1048 1048 1025 1046 1070 1097 Johnson Controls Unitary Products 294604-YTG-G-0511 DEZ024-060 (Continued) Size (Tons) Model 048 (4.0) DEZ 060 (5.0) DEZ Unit Speed Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) SCFM 1287 1596 1705 1806 1898 1580 1650 1854 2120 2214 0.2 W 222 397 476 561 652 394 448 605 856 968 RPM 695 817 858 895 929 859 888 972 1073 1104 SCFM 1513 1624 1726 1819 1504 1579 1783 2021 2089 External Static Pressure (Inch Water Gauge) 0.4 0.6 0.8 W RPM SCFM W RPM SCFM W 422 875 1432 447 934 1354 474 501 911 1545 526 966 1466 549 587 945 1646 610 995 1564 628 679 977 1736 698 1023 1646 709 420 917 476 945 1499 478 1003 1401 494 629 1020 1703 646 1065 1605 648 840 1102 1908 815 1127 1769 772 918 1121 1949 859 1136 1785 787 RPM 995 1021 1046 1069 1049 1104 1148 1148 SCFM 1276 1386 1476 1547 1528 1567 1576 1.0 W 501 571 639 706 659 685 689 RPM 1058 1077 1096 1112 1146 1154 1154 Bottom Duct Application DEY/DEX024-060 Size (Tons) Model Mode Low Cool 024 (2.0) DEX High Heat Low Cool 030 (2.5) DEX High Heat Low Cool 036 (3.0) DEX High Heat Low Cool 042 (3.5) DEX High Heat Low Cool 048 (4.0) DEX High Heat Thermostat Input Speed Tap CFM Y1 Y1 Y1 Y1 Y1+Y2 Y1+Y2 Y1+Y2 Y1+Y2 W1 W1 W1 Y1 Y1 Y1 Y1 Y1+Y2 Y1+Y2 Y1+Y2 Y1+Y2 W1 W1 W1 W1 Y1 Y1 Y1 Y1 Y1+Y2 Y1+Y2 Y1+Y2 Y1+Y2 W1 W1 W1 W1 Y1 Y1 Y1 Y1 Y1+Y2 Y1+Y2 Y1+Y2 Y1+Y2 W1 W1 W1 W1 Y1 Y1 Y1 Y1 Y1+Y2 Y1+Y2 Y1+Y2 Y1+Y2 W1 W1 W1 W1 COOL-A COOL-B COOL-C COOL-D COOL-A COOL-B COOL-C COOL-D HEAT-A HEAT-B HEAT-C COOL-A COOL-B COOL-C COOL-D COOL-A COOL-B COOL-C COOL-D HEAT-A HEAT-B HEAT-C HEAT-D COOL-A COOL-B COOL-C COOL-D COOL-A COOL-B COOL-C COOL-D HEAT-A HEAT-B HEAT-C HEAT-D COOL-A COOL-B COOL-C COOL-D COOL-A COOL-B COOL-C COOL-D HEAT-A HEAT-B HEAT-C HEAT-D COOL-A COOL-B COOL-C COOL-D COOL-A COOL-B COOL-C COOL-D HEAT-A HEAT-B HEAT-C HEAT-D 600 450 525 675 800 600 700 900 800 720 880 670 620 720 770 1000 925 1075 1150 1000 900 1100 1000 900 750 830 980 1200 1000 1100 1300 1200 1080 1275 1200 920 790 850 980 1400 1200 1300 1500 1225 1100 1350 1225 1050 920 980 1120 1600 1400 1500 1700 1600 1440 1760 1600 Johnson Controls Unitary Products External Static Pressure (Inch Water Gauge) 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Watts Watts Watts Watts Watts Watts Watts Watts Watts 57 74 91 108 126 143 161 179 197 39 54 69 84 100 117 134 152 171 47 63 79 95 112 129 146 164 182 71 88 106 124 142 161 179 198 216 99 117 137 156 176 196 217 237 258 57 74 91 108 126 143 161 179 197 76 94 112 130 148 167 186 205 224 126 146 166 187 208 231 253 277 300 99 117 137 156 80 98 116 135 120 140 160 180 61 78 95 113 130 148 166 184 201 54 70 87 104 121 138 156 173 191 70 88 106 124 142 160 178 197 215 81 99 118 136 155 174 193 213 232 159 179 200 222 246 270 296 323 350 129 148 169 190 211 233 256 280 304 194 214 236 260 285 312 341 371 403 233 254 277 302 330 360 392 427 463 159 179 200 222 120 139 159 180 206 227 249 274 159 179 200 222 120 139 159 180 201 222 244 267 291 76 94 113 131 150 168 187 206 225 97 116 135 155 174 194 215 236 256 150 170 191 213 236 260 285 311 337 261 283 306 333 362 394 429 467 507 159 179 200 222 246 270 296 323 350 206 227 249 274 300 328 357 389 422 325 346 372 401 434 471 511 556 604 261 283 306 333 196 217 239 263 308 330 355 383 261 283 306 333 139 166 195 224 255 286 319 352 386 100 124 149 176 205 235 266 299 333 117 143 170 198 227 257 289 322 356 159 188 218 249 281 313 346 379 414 338 383 426 468 509 549 589 627 664 245 281 318 354 390 426 462 497 533 290 330 370 409 447 485 523 560 596 391 439 486 532 576 618 660 700 739 256 293 330 367 203 237 270 304 314 356 397 438 256 293 330 367 184 216 248 280 313 346 380 414 449 139 166 195 224 255 286 319 352 386 159 188 218 249 281 313 346 379 414 211 245 279 313 348 382 417 452 486 448 500 551 600 647 693 736 779 819 338 383 426 468 509 549 589 627 664 391 439 486 532 576 618 660 700 739 508 565 620 672 723 772 818 863 905 448 500 551 600 647 359 405 449 493 535 546 606 663 718 771 448 500 551 600 647 - 43 294604-YTG-G-0511 DEY/DEX024-060 (Continued) Size (Tons) Model Mode Thermostat Input Speed Tap CFM Y1 Y1 Y1 Y1 Y1+Y2 Y1+Y2 Y1+Y2 Y1+Y2 W1 W1 W1 W1 COOL-A COOL-B COOL-C COOL-D COOL-A COOL-B COOL-C COOL-D HEAT-A HEAT-B HEAT-C HEAT-D 1170 1110 1210 1270 1750 1650 1800 1900 1900 1975 2150 2070 Low Cool 060 (5.0) DEY High Heat External Static Pressure (Inch Water Gauge) 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Watts Watts Watts Watts Watts Watts Watts Watts Watts 235 283 328 368 404 435 463 485 505 205 258 304 345 381 410 434 451 465 255 301 344 384 420 454 483 509 533 286 329 371 410 448 483 516 547 576 559 608 658 710 762 815 870 925 981 498 542 588 634 683 732 783 835 888 590 643 696 750 805 860 916 973 1030 654 715 775 836 895 955 1013 1072 654 715 775 836 895 703 772 839 904 968 823 913 999 1079 1154 767 847 923 997 1066 - DEQ024-060 Size (Tons) Model Mode Cool 024 (2.0) DEQ Heat Cool 030 (2.5) DEQ Heat Cool 036 (3.0) DEQ Heat Cool 042 (3.5) DEQ Heat Cool 048 (4.0) DEQ Heat Cool 060 (5.0) DEQ Heat 44 Thermostat Input Speed Tap CFM Y1 Y1 Y1 Y1 W1 W1 W1 Y1 Y1 Y1 Y1 W1 W1 W1 W1 Y1 Y1 Y1 Y1 W1 W1 W1 W1 Y1 Y1 Y1 Y1 W1 W1 W1 W1 Y1 Y1 Y1 Y1 W1 W1 W1 W1 Y1 Y1 Y1 Y1 W1 W1 W1 W1 COOL-A COOL-B COOL-C COOL-D HEAT-A HEAT-B HEAT-C COOL-A COOL-B COOL-C COOL-D HEAT-A HEAT-B HEAT-C HEAT-D COOL-A COOL-B COOL-C COOL-D HEAT-A HEAT-B HEAT-C HEAT-D COOL-A COOL-B COOL-C COOL-D HEAT-A HEAT-B HEAT-C HEAT-D COOL-A COOL-B COOL-C COOL-D HEAT-A HEAT-B HEAT-C HEAT-D COOL-A COOL-B COOL-C COOL-D HEAT-A HEAT-B HEAT-C HEAT-D 800 600 700 900 800 720 880 1000 925 1075 1150 1000 900 1100 1000 1200 1000 1100 1300 1200 1080 1275 1200 1400 1200 1300 1500 1225 1100 1350 1225 1600 1400 1500 1700 1600 1440 1760 1600 1500 1650 1800 1900 1900 1975 2150 2070 External Static Pressure (Inch Water Gauge) 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Watts Watts Watts Watts Watts Watts Watts Watts Watts 99 117 137 156 176 196 217 237 258 57 74 91 108 126 143 161 179 197 76 94 112 130 148 167 186 205 224 126 146 166 187 208 231 253 277 300 99 117 137 156 80 98 116 135 120 140 160 180 159 179 200 222 246 270 296 323 350 129 148 169 190 211 233 256 280 304 194 214 236 260 285 312 341 371 403 233 254 277 302 330 360 392 427 463 159 179 200 222 120 139 159 180 206 227 249 274 159 179 200 222 261 283 306 333 362 394 429 467 507 159 179 200 222 246 270 296 323 350 206 227 249 274 300 328 357 389 422 325 346 372 401 434 471 511 556 604 261 283 306 333 196 217 239 263 308 330 355 383 261 283 306 333 338 383 426 468 509 549 589 627 664 245 281 318 354 390 426 462 497 533 290 330 370 409 447 485 523 560 596 391 439 486 532 576 618 660 700 739 256 293 330 367 203 237 270 304 314 356 397 438 256 293 330 367 408 461 512 562 610 657 703 747 790 290 334 378 422 465 508 550 592 633 349 397 445 492 537 582 626 669 711 467 524 579 632 683 732 779 825 868 408 461 512 562 610 657 313 359 405 450 494 537 503 562 619 674 726 777 408 461 512 562 610 657 404 438 475 512 555 597 644 692 728 498 542 588 634 683 732 783 835 888 590 643 696 750 805 860 916 973 1030 654 715 775 836 895 955 1013 1072 654 715 775 836 895 703 772 839 904 968 823 913 999 1079 1154 767 847 923 997 1066 - Johnson Controls Unitary Products 294604-YTG-G-0511 DEZ024-060 Size (Tons) Model 024 (2.0) DEZ 030 (2.5) DEZ 036 (3.0) DEZ 042 (3.5) DEZ 048 (4.0) DEZ 060 (5.0) DEZ Unit Speed Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) SCFM 726 768 883 990 828 953 1091 1189 966 1148 1258 1361 1458 1241 1406 1536 1656 1287 1596 1705 1806 1898 1580 1650 1854 2120 2214 Johnson Controls Unitary Products 0.2 W 87 97 131 170 110 153 214 269 168 215 255 301 354 221 299 376 466 222 397 476 561 652 394 448 605 856 968 RPM 632 651 704 755 673 735 807 861 771 763 766 778 797 702 759 808 858 695 817 858 895 929 859 888 972 1073 1104 SCFM 629 679 812 934 759 894 1041 1144 1235 890 1062 1167 1267 1362 1151 1325 1461 1584 1687 1513 1624 1726 1819 1504 1579 1783 2021 2089 External Static Pressure (Inch Water Gauge) 0.4 0.6 0.8 W RPM SCFM W RPM SCFM W 99 739 110 754 147 797 736 162 889 651 177 187 839 868 202 920 791 216 985 245 952 913 257 125 771 172 823 824 189 909 234 883 983 253 958 910 269 288 927 1091 305 994 1027 318 347 970 1186 360 1028 1125 368 186 860 237 841 975 259 918 278 839 1075 301 911 980 325 325 845 1170 349 913 1070 372 379 859 1262 402 923 1156 423 245 778 1058 268 853 324 826 1242 349 893 1158 373 403 869 1384 427 928 1305 449 492 912 1509 515 966 1430 533 590 955 1611 610 1004 1527 620 422 875 1432 447 934 1354 474 501 911 1545 526 966 1466 549 587 945 1646 610 995 1564 628 679 977 1736 698 1023 1646 709 420 917 476 945 1499 478 1003 1401 494 629 1020 1703 646 1065 1605 648 840 1102 1908 815 1127 1769 772 918 1121 1949 859 1136 1785 787 RPM 979 1000 1022 1033 1061 1086 983 981 986 959 988 1019 1051 995 1021 1046 1069 1049 1104 1148 1148 SCFM 696 813 785 912 1007 964 1040 1072 1223 1344 1428 1276 1386 1476 1547 1528 1567 1576 1.0 W 227 261 273 316 352 393 436 396 468 542 615 501 571 639 706 659 685 689 RPM 1078 1090 1106 1132 1147 1048 1048 1025 1046 1070 1097 1058 1077 1096 1112 1146 1154 1154 45 294604-YTG-G-0511 Additional Static Resistance Size (Tons) Model 024 (2.0) DEZ DEQ DEX 030 (2.5) DEZ DEQ DEX 036 (3.0) DEZ DEQ DEX 042 (3.5) DEZ DEQ DEX 048 (4.0) DEZ DEQ DEX 060 (5.0) DEZ DEQ DEX CFM Wet Indoor Coil Economizer1 Filter/Frame Kit Electric Heat 500 600 700 800 900 1000 1100 1200 700 800 900 1000 1100 1200 1300 700 800 900 1000 1100 1200 1300 1400 1100 1200 1300 1400 1500 1600 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 0.01 0.01 0.01 0.01 0.01 0.02 0.03 0.04 0.01 0.01 0.01 0.02 0.03 0.04 0.07 0.01 0.01 0.01 0.02 0.03 0.04 0.04 0.04 0.03 0.04 0.04 0.04 0.05 0.06 0.03 0.04 0.04 0.04 0.04 0.04 0.05 0.05 0.06 0.07 0.03 0.04 0.04 0.04 0.04 0.04 0.05 0.05 0.06 0.07 0.00 0.00 0.00 0.01 0.01 0.01 0.01 0.02 0.00 0.01 0.01 0.01 0.01 0.02 0.03 0.00 0.01 0.01 0.01 0.01 0.02 0.03 0.04 0.01 0.02 0.03 0.04 0.05 0.06 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.07 0.08 0.08 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.07 0.08 0.08 0.01 0.02 0.02 0.02 0.02 0.02 0.03 0.03 0.02 0.02 0.02 0.02 0.03 0.03 0.17 0.02 0.02 0.02 0.02 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.04 0.05 0.03 0.03 0.03 0.03 0.04 0.05 0.05 0.06 0.06 0.07 0.03 0.03 0.03 0.03 0.04 0.05 0.05 0.06 0.06 0.07 0.02 0.03 0.03 0.03 0.04 0.04 0.05 0.06 0.03 0.03 0.04 0.04 0.05 0.06 0.03 0.03 0.04 0.04 0.05 0.06 0.07 0.08 0.05 0.06 0.07 0.08 0.09 0.10 0.05 0.06 0.07 0.08 0.09 0.10 0.11 0.11 0.11 0.12 0.05 0.06 0.07 0.08 0.09 0.10 0.11 0.11 0.11 0.12 1. The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. 46 Johnson Controls Unitary Products 294604-YTG-G-0511 Electric Heat Minimum Supply Air Size (Tons) Model Voltage DEZ DEQ DEX DEZ DEQ DEX 024 (2.0) 030 (2.5) DEX 036 (3.0) DEZ DEQ DEX 042 (3.5) DEZ DEQ DEX 048 (4.0) DEZ DEQ DEY 060 (5.0) DEZ DEQ Minimum Supply Air (CFM) Heater kW 10.0 15.0 5.0 7.5 20.0 25.0 208/230-1-60 630 630 800 - - - 208/230-1-60 630 630 800 800 - - 208/230-1-60 208/230-3-60 460-3-60 208/230-1-60 208/230-3-60 460-3-60 575-3-60 208/230-1-60 208/230-3-60 460-3-60 208/230-1-60 208/230-3-60 460-3-60 575-3-60 208/230-1-60 208/230-3-60 460-3-60 208/230-1-60 208/230-3-60 460-3-60 575-3-60 208/230-1-60 208/230-3-60 460-3-60 208/230-1-60 208/230-3-60 460-3-60 575-3-60 1070 1070 1070 1070 1070 1070 1070 1225 1225 1225 1225 1225 1225 1225 - 1070 1070 1070 1070 1070 1070 1070 1225 1225 1225 1225 1225 1225 1225 - 1070 1070 1070 1070 1070 1070 1070 1225 1225 1225 1225 1225 1225 1225 1200 1200 1200 1200 1200 1200 1200 1615 1615 1615 1615 1615 1615 1615 1070 1070 1070 1070 1070 1070 1070 1225 1225 1225 1225 1225 1225 1225 1430 1430 1430 1430 1430 1430 1430 1615 1615 1615 1615 1615 1615 1615 1430 1430 1430 1430 1430 1430 1430 1955 1955 1955 1955 1955 1955 1955 1430 1430 1430 1430 1430 1430 1430 1955 1955 1955 1955 1955 1955 1955 Indoor Blower Specifications Size (Tons) 024 (2.0) 030 (2.5) 036 (3.0) 042 (3.5) 048 (4.0) 060 (5.0) Model DEZ DEQ DEX DEZ DEQ DEX DEZ DEQ DEX DEZ DEQ DEX DEZ DEQ DEX DEZ DEQ DEX HP RPM Motor Eff. SF Frame 1/2 Variable 0.8 1.0 48 1/2 Variable 0.8 1.0 48 1/2 Variable 0.8 1.0 48 3/4 Variable 0.8 1.0 48 3/4 Variable 0.8 1.0 48 1 Variable 0.8 1.0 48 Johnson Controls Unitary Products 47 294604-YTG-G-0511 Electric Heat Multipliers Voltage Nominal Applied 208 230 460 575 240 480 600 kW Capacity Multipliers1 0.75 0.92 0.92 0.92 1. Electric heaters are rated at nominal voltage. Use this table to determine the electric heat capacity for heaters applied at lower voltages. Sound Performance Outdoor Sound Power Levels Size (Tons) 024 (2.0) 030 (2.5) 036 (3.0) 042 (3.5) 048 (4.0) 060 (5.0) Model Sound Rating1 dB (A) DEZ, DEQ DEX DEZ, DEQ DEX DEZ, DEQ DEX DEZ, DEQ DEX DEZ, DEQ DEX DEZ, DEQ DEY 80 73 79 77 74 78 74 76 80 79 80 79 125 72 61.5 66 60 65 63 64 67.5 71 71.5 68 68 Octave Band Centerline Frequency (Hz) 250 500 1000 2000 4000 70 65 76 66 72 64.5 68.5 66.5 62 60 67 67 76 75 66 62.5 64.5 75.5 62.5 59.5 64 67 68 67 65 65 76 73 64.5 62.5 65 68 69 63 59 68.5 69.5 69 66 63.5 72 74 73 69 67 69.5 71.5 75.5 68 67 71 74 73 72 72 70 73.5 73 68.5 66.5 8000 58 54 57 58.5 59 60 57 60 62 62 60 62.5 1. Rated in accordance with ARI 270 standard. 48 Johnson Controls Unitary Products 294604-YTG-G-0511 Electrical Data DEZ024-060 Cooling Only With/Without Electric Heat Size (Tons) Volt OD Fan Supply Motors Blower (each) Motor RLA LRA MCC FLA FLA Compressors (each) 024 (2.0) 208/230-1-60 8.3 43 13 1.3 4.1 030 (2.5) 208/230-1-60 13.1 74 21 1.3 4.1 208/230-1-60 14.7 74 23 1.3 4.1 208/230-3-60 9.1 68 14 1.3 4.1 036 (3.0) 042 (3.5) 460-3-60 4.5 34 7 0.8 4.1 575-3-60 3.8 28 6 0.6 6.0 208/230-1-60 15.7 88 25 1.7 6.0 208/230-3-60 9.3 68 15 1.7 6.0 460-3-60 5.1 34 8 1.0 6.0 575-3-60 3.8 28 6 0.8 6.0 208/230-1-60 16.8 115 25 1.7 6.0 208/230-3-60 11.2 120 18 1.7 6.0 048 (4.0) 460-3-60 5.1 50 8 1.0 6.0 575-3-60 4.5 40 7 0.8 6.0 Johnson Controls Unitary Products Electric Heat Option Model None 2NH04500506 2NH04500706 2NH04501006 None 2NH04500506 2NH04500706 2NH04501006 2NH04501506 None 2NH04500506 2NH04500706 2NH04501006 2NH04501506 None 2NH04501025 2NH04501525 None 2NH04501046 2NH04501546 None 2NH04501058 2NH04501558 None 2NH04500506 2NH04500706 2NH04501006 2NH04501506 None 2NH04501025 2NH04501525 None 2NH04501046 2NH04501546 None 2NH04501058 2NH04501558 None 2NH04501006 2NH04501506 2NH04502006 2NH04502506 None 2NH04501025 2NH04501525 2NH04502025 2NH04502525 None 2NH04501046 2NH04501546 2NH04502046 2NH04502546 None 2NH04501058 2NH04501558 2NH04502058 2NH04502558 MCA1 (Amps) kW Stages Amps 15.8 3.8 / 5 1 18.1 / 20.8 27.7 / 31.2 5.6 / 7.5 2 27.1 / 31.3 39 / 44.2 7.5 / 10 2 36.1 / 41.7 50.3 / 57.2 21.8 3.8 / 5 1 18.1 / 20.8 27.7 / 31.2 5.6 / 7.5 2 27.1 / 31.3 39 / 44.2 7.5 / 10 2 36.1 / 41.7 50.3 / 57.2 11.3 / 15 2 54.2 / 62.5 72.8 / 83.3 23.8 3.8 / 5 1 18.1 / 20.8 27.7 / 31.2 5.6 / 7.5 2 27.1 / 31.3 39 / 44.2 7.5 / 10 2 36.1 / 41.7 50.3 / 57.2 11.3 / 15 2 54.2 / 62.5 72.8 / 83.3 16.8 7.5 / 10 1 20.8 / 24.1 31.2 / 35.2 11.3 / 15 1 31.3 / 36.1 44.2 / 50.2 10.5 10 1 12 20.2 15 1 18 27.7 11.9 10 1 9.6 19.5 15 1 14.4 25.5 27.3 3.8 / 5 1 18.1 / 20.8 30.1 / 33.5 5.6 / 7.5 2 27.1 / 31.3 41.4 / 46.6 7.5 / 10 2 36.1 / 41.7 52.6 / 59.6 11.3 / 15 2 54.2 / 62.5 75.2 / 85.6 19.3 7.5 / 10 1 20.8 / 24.1 33.6 / 37.6 11.3 / 15 1 31.3 / 36.1 46.6 / 52.6 13.6 10 1 12 22.5 15 1 18 30.1 12.1 10 1 9.6 19.5 15 1 14.4 25.5 28.7 7.5 / 10 2 36.1 / 41.7 52.6 / 59.6 11.3 / 15 2 54.2 / 62.5 75.2 / 85.6 15 / 20 2 72.2 / 83.3 97.8 / 111.7 18.8 / 25 2 90.3 / 104.2 120.3 / 137.7 21.7 7.5 / 10 1 20.8 / 24.1 33.6 / 37.6 11.3 / 15 1 31.3 / 36.1 46.6 / 52.6 15 / 20 2 41.7 / 48.1 59.6 / 67.6 18.8 / 25 2 52.1 / 60.1 72.7 / 82.7 13.6 10 1 12 22.5 15 1 18 30.1 20 2 24.1 37.6 25 2 30.1 45.1 12.8 10 1 9.6 19.5 15 1 14.4 25.5 20 2 19.2 31.6 25 2 24.1 37.6 Max Fuse2/ Breaker3 Size (Amps) 20 30 / 35 40 / 45 60 / 60 30 30 / 35 40 / 45 60 / 60 80 / 90 30 35 / 35 40 / 45 60 / 60 80 / 90 25 35 / 40 45 / 60 15 25 30 15 20 30 35 40 / 40 45 / 50 60 / 60 80 / 90 25 35 / 40 50 / 60 15 25 35 15 20 30 35 60 / 60 80 / 90 100 / 125 125 / 150 30 35 / 40 50 / 60 60 / 70 80 / 90 15 25 35 40 50 15 20 30 35 40 49 294604-YTG-G-0511 DEZ024-060 Cooling Only With/Without Electric Heat (Continued) Size (Tons) Volt OD Fan Supply Motors Blower (each) Motor RLA LRA MCC FLA FLA Compressors (each) 208/230-1-60 26.2 150 41 2.2 7.6 208/230-3-60 17.9 120 28 2.2 7.6 060 (5.0) 460-3-60 9.6 70 15 1.1 7.6 575-3-60 7.4 53 12 0.8 7.6 Electric Heat Option Model None 2NH04501006 2NH04501506 2NH04502006 2NH04502506 None 2NH04501025 2NH04501525 2NH04502025 2NH04502525 None 2NH04501046 2NH04501546 2NH04502046 2NH04502546 None 2NH04501058 2NH04501558 2NH04502058 2NH04502558 MCA1 (Amps) kW Stages Amps 42.6 7.5 / 10 2 36.1 / 41.7 54.6 / 61.6 11.3 / 15 2 54.2 / 62.5 77.2 / 87.6 15 / 20 2 72.2 / 83.3 99.8 / 113.7 18.8 / 25 2 90.3 / 104.2 122.3 / 139.7 32.2 7.5 / 10 1 20.8 / 24.1 35.6 / 39.6 11.3 / 15 1 31.3 / 36.1 48.6 / 54.6 15 / 20 2 41.7 / 48.1 61.6 / 69.6 18.8 / 25 2 52.1 / 60.1 74.7 / 84.7 20.7 10 1 12 24.5 15 1 18 32.1 20 2 24.1 39.6 25 2 30.1 47.1 16.9 10 1 9.6 21.5 15 1 14.4 27.5 20 2 19.2 33.6 25 2 24.1 39.6 Max Fuse2/ Breaker3 Size (Amps) 60 60 / 70 80 / 90 100 / 125 125 / 150 40 45 / 50 50 / 60 70 / 70 80 / 90 25 30 35 40 50 20 25 30 35 40 1. Minimum Circuit Ampacity. 2. Maximum Over Current Protection per standard UL 1995. 3. Fuse or HACR circuit breaker size installed at factory or field installed. 50 Johnson Controls Unitary Products 294604-YTG-G-0511 DEQ024-060 Cooling Only With/Without Electric Heat Size (Tons) Volt OD Fan Supply Motors Blower (each) Motor RLA LRA MCC FLA FLA Compressors (each) 024 (2.0) 208/230-1-60 8.3 43 13 1.2 4.3 030 (2.5) 208/230-1-60 13.1 74 21 1.2 4.3 208/230-1-60 14.7 74 23 1.2 4.3 208/230-3-60 9.1 68 14 1.2 4.3 036 (3.0) 042 (3.5) 460-3-60 4.5 34 7 0.8 2.2 575-3-60 3.8 28 6 0.6 1.7 208/230-1-60 15.7 88 25 1.4 6.8 208/230-3-60 9.3 68 15 1.4 6.8 460-3-60 5.1 34 8 0.8 3.4 575-3-60 3.8 28 6 0.6 2.7 208/230-1-60 20.5 115 32 1.7 6.8 208/230-3-60 16.0 120 25 1.7 6.8 048 (4.0) 460-3-60 7.7 50 12 1.0 3.4 575-3-60 6.4 40 10 0.8 2.7 Johnson Controls Unitary Products Electric Heat Option Model None 2NH04500506 2NH04500706 2NH04501006 None 2NH04500506 2NH04500706 2NH04501006 2NH04501506 None 2NH04500506 2NH04500706 2NH04501006 2NH04501506 None 2NH04501025 2NH04501525 None 2NH04501046 2NH04501546 None 2NH04501058 2NH04501558 None 2NH04500506 2NH04500706 2NH04501006 2NH04501506 None 2NH04501025 2NH04501525 None 2NH04501046 2NH04501546 None 2NH04501058 2NH04501558 None 2NH04501006 2NH04501506 2NH04502006 2NH04502506 None 2NH04501025 2NH04501525 2NH04502025 2NH04502525 None 2NH04501046 2NH04501546 2NH04502046 2NH04502546 None 2NH04501058 2NH04501558 2NH04502058 2NH04502558 MCA1 (Amps) kW Stages Amps 15.9 3.8 / 5 1 18.1 / 20.8 27.9 / 31.4 5.6 / 7.5 2 27.1 / 31.3 39.2 / 44.4 7.5 / 10 2 36.1 / 41.7 50.5 / 57.5 --21.9 3.8 / 5 1 18.1 / 20.8 27.9 / 31.4 5.6 / 7.5 2 27.1 / 31.3 39.2 / 44.4 7.5 / 10 2 36.1 / 41.7 50.5 / 57.5 11.3 / 15 2 54.2 / 62.5 73.1 / 83.5 23.9 3.8 / 5 1 18.1 / 20.8 27.9 / 31.4 5.6 / 7.5 2 27.1 / 31.3 39.2 / 44.4 7.5 / 10 2 36.1 / 41.7 50.5 / 57.5 11.3 / 15 2 54.2 / 62.5 73.1 / 83.5 16.9 7.5 / 10 1 20.8 / 24.1 31.4 / 35.4 11.3 / 15 1 31.3 / 36.1 44.5 / 50.5 8.6 10 1 12 17.8 15 1 18 25.3 7.1 10 1 9.6 14.2 15 1 14.4 20.2 27.8 3.8 / 5 1 18.1 / 20.8 31.1 / 34.5 5.6 / 7.5 2 27.1 / 31.3 42.4 / 47.6 7.5 / 10 2 36.1 / 41.7 53.6 / 60.6 11.3 / 15 2 54.2 / 62.5 76.2 / 86.6 19.8 7.5 / 10 1 20.8 / 24.1 34.6 / 38.6 11.3 / 15 1 31.3 / 36.1 47.6 / 53.6 10.6 10 1 12 19.3 15 1 18 26.8 8.1 10 1 9.6 15.4 15 1 14.4 21.4 34.1 7.5 / 10 2 36.1 / 41.7 53.6 / 60.6 11.3 / 15 2 54.2 / 62.5 76.2 / 86.6 15 / 20 2 72.2 / 83.3 98.8 / 112.7 18.8 / 25 2 90.3 / 104.2 121.3 / 138.7 28.5 7.5 / 10 1 20.8 / 24.1 34.6 / 38.6 11.3 / 15 1 31.3 / 36.1 47.6 / 53.6 15 / 20 2 41.7 / 48.1 60.6 / 68.6 18.8 / 25 2 52.1 / 60.1 73.7 / 83.7 14 10 1 12 19.3 15 1 18 26.8 20 2 24.1 34.3 25 2 30.1 41.8 11.5 10 1 9.6 15.4 15 1 14.4 21.4 20 2 19.2 27.4 25 2 24.1 33.4 Max Fuse2/ Breaker3 Size (Amps) 20 30 / 35 40 / 45 60 / 60 30 30 / 35 40 / 45 60 / 60 80 / 90 30 35 / 35 40 / 45 60 / 60 80 / 90 25 35 / 40 45 / 60 15 20 30 15 15 25 35 40 / 40 45 / 50 60 / 70 80 / 90 25 35 / 40 50 / 60 15 20 30 15 20 25 45 60 / 70 80 / 90 100 / 125 125 / 150 35 40 / 40 50 / 60 70 / 70 80 / 90 20 20 30 35 45 15 20 25 30 35 51 294604-YTG-G-0511 DEQ024-060 Cooling Only With/Without Electric Heat (Continued) Size (Tons) Volt OD Fan Supply Motors Blower (each) Motor RLA LRA MCC FLA FLA Compressors (each) 208/230-1-60 26.2 150 41 2.8 9.1 208/230-3-60 17.9 120 28 2.8 9.1 060 (5.0) 460-3-60 8.3 70 13 1.4 4.6 575-3-60 7.4 53 12 1.1 3.6 Electric Heat Option Model None 2NH04501006 2NH04501506 2NH04502006 2NH04502506 None 2NH04501025 2NH04501525 2NH04502025 2NH04502525 None 2NH04501046 2NH04501546 2NH04502046 2NH04502546 None 2NH04501058 2NH04501558 2NH04502058 2NH04502558 MCA1 (Amps) kW Stages Amps 44.7 7.5 / 10 2 36.1 / 41.7 56.5 / 63.5 11.3 / 15 2 54.2 / 62.5 79.1 / 89.5 15 / 20 2 72.2 / 83.3 101.7 / 115.5 18.8 / 25 2 90.3 / 104.2 124.2 / 141.6 34.3 7.5 / 10 1 20.8 / 24.1 37.4 / 41.4 11.3 / 15 1 31.3 / 36.1 50.5 / 56.5 15 / 20 2 41.7 / 48.1 63.5 / 71.5 18.8 / 25 2 52.1 / 60.1 76.5 / 86.6 16.4 10 1 12 20.8 15 1 18 28.3 20 2 24.1 35.8 25 2 30.1 43.3 14 10 1 9.6 16.5 15 1 14.4 22.5 20 2 19.2 28.6 25 2 24.1 34.6 Max Fuse2/ Breaker3 Size (Amps) 60 70 / 70 80 / 90 110 / 125 125 / 150 45 45 / 50 60 / 60 70 / 80 80 / 90 20 25 30 40 45 20 20 25 30 35 1. Minimum Circuit Ampacity. 2. Maximum Over Current Protection per standard UL 1995. 3. Fuse or HACR circuit breaker size installed at factory or field installed. DEX024-048 Cooling Only With/Without Electric Heat Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) FLA Supply Blower Motor FLA 024 (2.0) 208/230-1-60 10.2 52 16 1.2 4.3 030 (2.5) 208/230-1-60 14.1 70 22 1.2 4.3 208/230-1-60 16.6 82 26 1.2 4.3 208/230-3-60 11.1 58 17 1.2 4.3 4.5 29 7 0.8 4.3 208/230-1-60 16.6 96 26 1.4 6.8 208/230-3-60 13.4 88 21 1.4 6.8 44 10 0.8 6.8 036 (3.0) 460-3-60 042 (3.5) 460-3-60 52 6.1 Electric Heat Option Model None 2NH04500506 2NH04500706 2NH04501006 None 2NH04500506 2NH04500706 2NH04501006 2NH04501506 None 2NH04500506 2NH04500706 2NH04501006 2NH04501506 None 2NH04501025 2NH04501525 None 2NH04501046 2NH04501546 None 2NH04500506 2NH04500706 2NH04501006 2NH04501506 None 2NH04501025 2NH04501525 None 2NH04501046 2NH04501546 kW Stages Amps 3.8/5 1 18.1/20.8 5.6/7.5 2 27.1/31.3 7.5/10 2 36.1/41.7 3.8/5 1 18.1/20.8 5.6/7.5 2 27.1/31.3 7.5/10 2 36.1/41.7 11.3/15 2 54.2/62.5 3.8/5 1 18.1/20.8 5.6/7.5 2 27.1/31.3 7.5/10 2 36.1/41.7 11.3/15 2 54.2/62.5 7.5/10 1 20.8/24.1 11.3/15 1 31.3/36.1 10 1 12 15 1 18 3.8/5 1 18.1/20.8 5.6/7.5 2 27.1/31.3 7.5/10 2 36.1/41.7 11.3/15 2 54.2/62.5 7.5/10 1 20.8/24.1 11.3/15 1 31.3/36.1 10 1 12 15 1 18 MCA1 (Amps) 18.3 27.9 / 31.4 39.2 / 44.4 50.5 / 57.5 23.1 27.9 / 31.4 39.2 / 44.4 50.5 / 57.5 73.1 / 83.5 26.3 27.9 / 31.4 39.2 / 44.4 50.5 / 57.5 73.1 / 83.5 19.4 31.4 / 35.4 44.5 / 50.5 10.7 20.4 27.9 29 31.1 / 34.5 42.4 / 47.6 53.6 / 60.6 76.2 / 86.6 25 34.6 / 38.6 47.6 / 53.6 15.4 23.5 31.1 Max Fuse2/ Breaker3 Size (Amps) 25 30 / 35 40 / 45 60 / 60 30 35 / 35 40 / 45 60 / 60 80 / 90 35 35 / 40 40 / 45 60 / 60 80 / 90 25 35 / 40 45 / 60 15 25 30 35 40 / 45 45 / 50 60 / 70 80 / 90 30 35 / 40 50 / 60 20 25 35 Johnson Controls Unitary Products 294604-YTG-G-0511 DEX024-048 Cooling Only With/Without Electric Heat (Continued) Size (Tons) Volt RLA LRA 048 (4.0) MCC OD Fan Motors (each) FLA Supply Blower Motor FLA Compressors (each) 208/230-1-60 21.1 96 33 1.7 6.8 208/230-3-60 13.4 88 21 1.7 6.8 41 10 1.0 6.8 460-3-60 6.4 Electric Heat Option Model None 2NH04501006 2NH04501506 2NH04502006 2NH04502506 None 2NH04501025 2NH04501525 2NH04502025 2NH04502525 None 2NH04501046 2NH04501546 2NH04502046 2NH04502546 MCA1 (Amps) kW Stages Amps 34.9 7.5/10 2 36.1/41.7 53.6 / 60.6 11.3/15 2 54.2/62.5 76.2 / 86.6 15/20 2 72.2/83.3 98.8 / 112.7 18.8/25 2 90.3/104.2 121.3 / 138.7 25.3 7.5/10 1 20.8/24.1 34.6 / 38.6 11.3/15 1 31.3/36.1 47.6 / 53.6 15/20 2 41.7/48.1 60.6 / 68.6 18.8/25 2 52.1/60.1 73.7 / 83.7 15.9 10 1 12 23.5 15 1 18 31.1 20 2 24.1 38.6 25 2 30.1 46.1 Max Fuse2/ Breaker3 Size (Amps) 45 60 / 70 80 / 90 100 / 125 125 / 150 35 35 / 40 50 / 60 70 / 70 80 / 90 20 25 35 40 50 1. Minimum Circuit Ampacity. 2. Maximum Over Current Protection per standard UL 1995. 3. Fuse or HACR circuit breaker size installed at factory or field installed. DEY060 Cooling Only With/Without Electric Heat Size (Tons) Volt RLA LRA 060 (5.0) MCC OD Fan Motors (each) FLA Supply Blower Motor FLA Compressors (each) 208/230-1-60 25.6 118 40 1.7 9.1 208/230-3-60 17.6 123 28 1.7 9.1 62 14 1.0 9.1 460-3-60 9.0 Electric Heat Option Model None 2NH04501006 2NH04501506 2NH04502006 2NH04502506 None 2NH04501025 2NH04501525 2NH04502025 2NH04502525 None 2NH04501046 2NH04501546 2NH04502046 2NH04502546 MCA1 (Amps) kW Stages Amps 42.8 7.5/10 2 36.1/41.7 56.5 / 63.5 11.3/15 2 54.2/62.5 79.1 / 89.5 15/20 2 72.2/83.3 101.7 / 115.5 18.8/25 2 90.3/104.2 124.2 / 141.6 32.8 7.5/10 1 20.8/24.1 37.4 / 41.4 11.3/15 1 31.3/36.1 50.5 / 56.5 15/20 2 41.7/48.1 63.5 / 71.5 18.8/25 2 52.1/60.1 76.5 / 86.6 21.4 10 1 12 26.4 15 1 18 33.9 20 2 24.1 41.4 25 2 30.1 49 Max Fuse2/ Breaker3 Size (Amps) 60 60 / 70 80 / 90 110 / 125 125 / 150 40 45 / 50 60 / 60 70 / 80 80 / 90 30 30 35 45 50 1. Minimum Circuit Ampacity. 2. Maximum Over Current Protection per standard UL 1995. 3. Fuse or HACR circuit breaker size installed at factory or field installed. Johnson Controls Unitary Products 53 294604-YTG-G-0511 Typical Wiring Diagrams Typical DEZ024-060 Cooling Only 208/230-1-60 volt Wiring Diagram 54 Johnson Controls Unitary Products 294604-YTG-G-0511 Typical DEZ036-060 Cooling Only 208/230-3-60 volt Wiring Diagram Johnson Controls Unitary Products 55 294604-YTG-G-0511 Typical DEZ036-060 Cooling Only 460/575-3-60 volt Wiring Diagram 56 Johnson Controls Unitary Products 294604-YTG-G-0511 Typical DEQ024-048 Cooling Only 208/230-1-60 volt Wiring Diagram Johnson Controls Unitary Products 57 294604-YTG-G-0511 Typical DEQ060 Cooling Only 208/230-1-60 volt Wiring Diagram 58 Johnson Controls Unitary Products 294604-YTG-G-0511 Typical DEQ036-048 Cooling Only 208/230-3-60 volt Wiring Diagram Johnson Controls Unitary Products 59 294604-YTG-G-0511 Typical DEQ060 Cooling Only 208/230-3-60 volt Wiring Diagram 60 Johnson Controls Unitary Products 294604-YTG-G-0511 Typical DEQ036-048 Cooling Only 460/575-3-60 volt Wiring Diagram Johnson Controls Unitary Products 61 294604-YTG-G-0511 Typical DEQ060 Cooling Only 460/575-3-60 volt Wiring Diagram 62 Johnson Controls Unitary Products 294604-YTG-G-0511 Typical DEX024-048/DEY060 Cooling Only 208/230-1-60 volt Wiring Diagram Johnson Controls Unitary Products 63 294604-YTG-G-0511 Typical DEX036-048/DEY060 Cooling Only 208/230-3-60 volt Wiring Diagram 64 Johnson Controls Unitary Products 294604-YTG-G-0511 Typical DEX036-048/DEY060 Cooling Only 460-3-60 volt Wiring Diagram Johnson Controls Unitary Products 65 294604-YTG-G-0511 Weights and Dimensions Unit 4 Point Load Weight "D" CENTER OF GRAVITY FRONT OF UNIT "C" "A" 49-1/8 "B" X Weight (lbs.) Center of Gravity Size Model (Tons) Shipping Operating X Y DEZ 379 374 23 23.25 024 DEQ 351 346 22.25 25 (2.0) DEX 360 355 22.25 25 DEZ 380 375 23 22.25 030 DEQ 391 386 22.25 25 (2.5) DEX 395 390 22.25 25 DEZ 384 379 23 22.25 036 DEQ 401 396 22.25 25 (3.0) DEX 405 400 22.25 25 DEZ 405 400 23 21.25 042 DEQ 411 406 22.25 25 (3.5) DEX 415 410 22.25 25 DEZ 406 401 21.5 21.75 048 DEQ 445 440 22.25 25 (4.0) DEX 445 440 22.25 25 DEZ 410 405 23.5 22.75 060 DEQ 457 452 22.25 25 (5.0) DEY 465 460 22.25 25 Y 47-1/4 4 Point Load Location (lbs.) A B C D 92 85 95 102 94 82 79 91 96 84 81 93 88 82 99 106 105 92 88 101 106 92 89 102 89 83 100 107 108 94 91 104 109 95 92 105 90 83 109 118 110 96 93 106 111 97 94 108 98 80 101 123 120 104 101 115 120 104 101 115 95 92 107 110 123 107 103 119 125 109 105 121 Unit Accessory Weights Unit Accessory Model Add Economizer Add Electric Heat1 All DEZ, DEQ, DEY, DEX Weight (lbs.) Shipping Operating 45 40 13 12 1. Weight given is for the maximum heater size available (25 kW). 66 Johnson Controls Unitary Products 294604-YTG-G-0511 Cooling Only Unit Dimensions HIGH VOLTAGE CONN. 7/8" DIA. KNOCKOUT FRONT COMPRESSOR SERVICE ACCESS COMPARTMENT PANEL HIGH VOLTAGE CONN. 1-31/32" DIA. KNOCKOUT LOW VOLTAGE CONN. 7/8" DIA. KNOCKOUT “A” 2-3/8 (OVERALL) SIDE SUPPLY AIR OPENING REFRIGERANT CONNECTIONS SIDE RETURN AIR OPENING ELECTRICAL/FILTER SERVICE ACCESS COMPARTMENT PANEL 17-1/4 28-1/4 22-1/4 49-1/8 (OVERALL) 17-1/4 2-1/2 28-1/4 22-1/4 47-1/4 HIGH VOLTAGE CONN. 1-23/64" DIA. KNOCKOUT (OVERALL) 3-3/4 1-1/2 4-1/2 UNIT CONDENSATE CONNECTION 3/4" NPTF (TRAP REQUIRED) Cooling Only Unit Dimensions Unit Size Dimensions “A” 024, 030, 036, 0421 33-1/2 0422, 048, 060 41-1/2 1. DEZ Models. 2. DEX Models. Cooling Only Unit Clearances Distance (in.) Direction Distance (in.) Direction Top1 36 Right 24 Front 12 Left 24 Rear 0 Bottom2 3 0 1. Units must be installed outdoors. Over hanging structure or shrubs should not obscure condenser air discharge outlet. 2. Units may be installed on combustable floors made from wood or class A, B or C roof covering materials. 3. Minimum Clearance of 1inch all sides of supply air duct for the first 3 foot of duct for 20 & 25 kW., zero inches there after. For all other heaters, zero inch clearance all sides for entire length of duct. Note: For units applied with a roof curb, the minimum clearance may be reduced from 1 inch to 1/2 inch between combustible roof curb material and this supply air duct. Johnson Controls Unitary Products 67 294604-YTG-G-0511 Unit Dimensions Front and Bottom HIGH VOLTAGE CONN. 1-3/32" DIA. KNOCKOUT 8-7/8 11-7/8 19-1/4 FRONT GAS SUPPLY 1-5/8" DIA. KNOCKOUT (1/2" NPTF CONNECTION) LOW VOLTAGE CONN. 7/8" DIA. KNOCKOUT LOW VOLTAGE CONN. 7/8" DIA. KNOCKOUT HIGH VOLTAGE CONN. 1-31/32" x 7/8" KNOCKOUT 4-5/8 CONDENSATE DRAIN 3/4" NPTF 40-1/2 26-3/4 22-1/2 43-1/2 6 Unit Dimensions Back and Bottom SIDE SUPPLY AIR OPENING *CONDENSER COIL 14-1/2 28-3/8 14-1/2 BACK BOTTOM SUPPLY AIR OPENING 3-3/8 SIDE RETURN AIR OPENING 14-1/2 4 4-1/4 1-3/4 15 15 1-3/4 15 28-9/16 68 3-1/2 1-3/4 BOTTOM RETURN AIR OPENING Johnson Controls Unitary Products 294604-YTG-G-0511 Unit Typical Duct Applications ROOF CURB INSTALLATION REAR DUCT ROOF CURB INSTALLATION BOTTOM DUCT SLAB ON GROUND INSTALLATION Unit Typical Slab on Ground Installation SUPPLY AIR DUCT RETURN AIR DUCT FIELD SUPPLIED DISCONNECT SWITCH LOCATED TO REAR OF UNIT TO POWER SUPPLY CONTROL WIRING TO INDOOR THERMOSTAT Johnson Controls Unitary Products 69 294604-YTG-G-0511 Unit Typical Roof Curb Installation FIELD SUPPLIED DISCONNECT SWITCH MOUNTED ON UNIT TO POWER SUPPLY CONTROL WIRING TO INDOOR THERMOSTAT SUPPLY AIR DUCT RETURN AIR DUCT Unit Accessory Dimensions Roof Curb1 RECOMMENDED DUCT SIZE 17-1/2" x 16-3/4" 42-2/3 40-3/4 3-1/2 45-1/8 17-5/8 17-1/4 43-1/4 OPENING FOR RETURN AIR DUCT 22 OPENING FOR SUPPLY AIR DUCT 14 1 RECOMMENDED DUCT SIZE 17-1/8" x 21-1/2" 1. 8” Roof Curb also available. 70 Johnson Controls Unitary Products 294604-YTG-G-0511 Roof Curb Cross Section \ 1" 3/4" x 1" WIDE GASKETING FOR CURB FRAME AND ALL DUCT SUPPORT SURFACES UNIT BASE UNIT BASE RAIL WOOD NAILER COUNTERFLASHING 8" MIN. ABOVE FINISHED ROOF 14" CANT STRIP CURB FRAME INSULATION AND ROOFING MATERIAL INSULATION ROOF DECK AND ROOFING MATERIAL Johnson Controls Unitary Products 71 Subject to change without notice. Printed in U.S.A. Copyright © 2011 by Johnson Controls, Inc. All rights reserved. Johnson Controls Unitary Products 5005 York Drive 294604-YTG-G-0511 Supersedes: 294604-YTG-F-1210