LEISTUNG LUFT 3 LUFT 3 Characteristics The lung ventilator for Intensive Care Units (ICU) LUFT3 with integrated 17" touchscreen technology, offers a full range of ventilation modes, allowing the monitoring of the patient's condition. Its relation of functions make it suitable for adult, pediatric and neonatal patients. Graphic Interface Ventilation Modes Adult / Pediatric Neonatal VCV Assisted / Controlled VCV Assisted / Controlled PCV Assisted / Controlled PCV Assisted / Controlled PSV/CPAP PSV/CPAP PRVC SIMV (PCV) + PSV SIMV (VCV) + PSV Continuos Flow SIMV (PCV) + PSV Nasal CPAP MMV + PSV Backup (all the spontaneous modes): PSV + VT Assured Backup Ventilation (VCV) Biphasic Pressure (APRV+BIPAP) Backup Ventilation (PCV) NIV Backup (all the spontaneous modes): Backup Ventilation (VCV) Backup Ventilation (PCV) Initial Configuration Screen Operation Display: Patient Setup Gerder Height Automatic Theoretical Weight Value mL/kg Ventilation Level Artificial Airway Type Humidification Type Calibration Tests Circuit Complacency Measurement Last Patient Function Ventilatory variables programming. Pressure bargraph. Customized selection up to 5 simultaneous graphics: Pressure / Time Flow / Time Volume / Time Volume / Pressure Adult and Pediatric Flow / Volume Pressure / Flow Plethysmography ETCO2 / Time ETCO2 / Volume NEONATAL: up to 3 simultaneous graphics: Pressure / Time Flow / Time Volume / Time Neonatal Plethysmography ETCO2 / Time Special Setup Touch Screen Calibration. Easy Firmware upgrading without opening the ventilator. Gas measurements with BTPS corrections. Programmable nebulization time with automatic inspiration flow L compression. 100% Oxygen up to 20 min. with alarms silence for 30 sec. LEISTUNG PATIENT Patient interface adequacy or circuit change without needing to CIRCUIT 8.0 165 sutdown the equipment and maintaining the historical log of the cm Man Adult Heigth mm Tube Diameter Active 60.0 patient. kg Pediatric Woman Alarm´s volume adjustment. Ideal Weight Cannula Pasive 8 mL/kg Neonatal Altitude compensation. Language selection. LUFT 3 Last Patient Volume Mask Start Tests PATIENT CIRCUIT TEST Hold circuit output closed News Automatic calculation of the theoreotical weight and interface selection according to the patient. Up to 5 selectable graphics simultaneous. Customized Touch function lock. Configuration Monitored variables setup. Stress Index Measurement. Volumetric Capnography´s arch graphic. Parameters Alarms Monitored Parameters Programmable Parameters Lung Mechanics Time Constant FiO2 AutoPEEP Maximum Pressure Expiratory Flow Wave Form: Dynamic Compliance Minimum Pressure Programmable I:E Square Static Compliance Max. Expired Minute Volume TI/Ttot Sinusoidal PV Curve with Low Flow Min. Expired Minute Volume Peak Inspiratory Flow: Ascending Slow Vital Capacity Maximum Expired TV Descending P0.1 Minimum Expired TV 50% Descending Tobin Index Max. Respiratory Frequency Stress Index Apnea (Distal & Proximal) Peak Expiratory Flow: (Distal & Proximal) Expiratory Tidal Volume: Rise time Inspiratory Time PEEP Respiratory Frequency Auxiliary Function Tidal Volume Nebulizer (Distal & Proximal) Pressure Control 100% Oxygen Automatic Compressible Volume Pressure Support Manual Inspiratory Trigger Interrupted Cycle FiO2 PEEP TGI Inverted I:E Ratio Leakage Sensibility: (Distal & Proximal) Minute Volume: Respiratory Frequency Power Failure Pressure / Flow Peak Pressure Apnea Time Plateau Pressure Inspiratory Pause Mean Pressure Sigh Base Pressure (PEEP) Expiratory Sensibility FiO2 Low Gas Supply Pressure Low Battery Safety System Internal Battery. Inspiratory Time Expiratory Time Optionals Tendencies Volumetric Capnography Alarms Log Inspired CO2 Inspiratory Resistance ETCO2 Expiratory Resistance Heart Rate SpO2 SpO2/FiO2 Automatic Gases Compensation. Automatic Opening of the Pressure Regulator Valves. Automatic Notification of the Hours of use without Locking the Equipment. Possibility of Operating without the Expiratory Flow Sensor or without the O2 Cell. Leistung Equipamentos Ltda. João Ropelatto, 202 St. Nereu Ramos Dt. - 89.265-520 Jaraguá do Sul - SC - Brazil Phone/Fax: (47) 3371-2741 E-mail: leistung@leistungbrasil.com Website: www.leistungbrasil.com Operating authorization ANVISA No.: GHL3983MX9H2 GMP Certiļ¬cate MADE IN BRAZIL