Errata for AWS D1.4/D1.4M:2011, Structural Welding Code—Reinforcing Steel (updated 6/7/2013) Page 11 – Figure 3.2 – Correct all instances of “TO” with “to.” Page 27 – Clause 6.1.2.2 – Correct “AWS D12.1” reference to “AWS D1.1.” Page 27 – Clause 6.2.1.1 – Correct “Table 6.1” reference to “Table 6.2.” Page 32 – Table 6.1 – Correct “Maximum Electrode Diametery” to “Maximum Electrode Diameter.” Page 34 – Table 6.3 – Correct row three by adding “or 6.5(D)]” and row four by deleting “(D)” and replacing it with “(E)” as follows: Page 35 – Table 6.4 – Correct row three for Direct Butt Joint under the Fillet Joint column to “F, H, V” as attached: Page 35 – Table 6.4 – Replace “V” in row four of Direct Butt Joint under the Fillet Joint column to “OH” as attached: Page 40 – Figure 6.5(C) —Replace “8” with “B”. Filename: errata_d1-4-2011 Replace “8” with “B” Pages 40-41 – Table 6.5 – Replace all instances of “L1” with “L1.” Pages 40-42 – Table 6.5 and 6.6 – Replace all instances of “LMIN” with “Lmin.” Page 59 – Annex B – Correct cross-sectional area of bar size number 18 from “258” to “2581.” Filename: errata_d1-4-2011 Filename: errata_d1-4-2011