MR. DENNIS L. ALAG OIC-General Manager TIELCO From: Mr. Jaime R. Remo PLDT-SLZ FPM-Coordinator Date: Ref. No. Work Order Number : Project Proponent : Project Engineer : Project Title/ Description: To: To be accomplished by TIELCO ` PROGRESO ESTE ( TUQUIS ODIONGAN ROMBLON) Item No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Pole No. 117-D 117-E 117-F 117-G 117G-A 117-H 117-I 117-J 117-K 117-L 117-M 117-N 117-O NPT NPT NPT NPT NPT NPT NPT Attachment Data: Cable Position Location (Street name [include landmark]) Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd., Near Store Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd. Description: 24F (FOC) Weight: 140 (kg/km) Length: 4.213 (km) Diameter: 11.3 (mm, for MAIN Cable) No. of pairs: (If Telephone cable) NOTE: Existing (found on site) C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 As per Pole User New Existing (mm) New/Add'l (mm) C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 1. Install down-guy on all angle run, corner run & dead-end construction before cable stringing. 2. Put color code on new & old cables and dropwires. 3. Avoid low sagging cable below 18 feet from ground level. REQUESTED BY: To be accomplished by TIELCO Cable Attachment MR. JAIME R. REMO PLDT-SLZ FPM-Coordinator/Date (signature over printed name) Page (1) of 2 RTA Form of PROGRESO ESTE ( TUQUIS ODIONGAN ROMBLON.xls Cable Attachment Existing RTA Inventory New Attachment Approved Disapproved Alley Arm Existing For Installation Type P/C Size TIELCO Rep./Date Legend REMARKS TIELCO Rep./Date MR. DENNIS L. ALAG OIC-General Manager TIELCO From: Mr. Jaime R. Remo PLDT-SLZ FPM-Coordinator Date: Ref. No. Work Order Number : Project Proponent : Project Engineer : Project Title/ Description: To: To be accomplished by TIELCO ` PROGRESO ESTE ( TUQUIS ODIONGAN ROMBLON) Item No. 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 Pole No. NPT NPT NPT NPT NPT NPT NPT NPT NPT NPT NPT NPT NPT NPT NPT Attachment Data: Cable Position Location (Street name [include landmark]) Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd. Looc - Odiongan Rd., Near Store Looc - Odiongan Rd., Near Store Looc - Odiongan Rd. Looc - Odiongan Rd., Near Store Looc - Odiongan Rd. ***Nothing follows*** Description: 24F (FOC) Weight: 140 (kg/km) Length: 4.213 (km) Diameter: 11.3 (mm, for MAIN Cable) No. of pairs: (If Telephone cable) NOTE: Existing (found on site) C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 As per Pole User New Existing (mm) New/Add'l (mm) C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 1. Install down-guy on all angle run, corner run & dead-end construction before cable stringing. 2. Put color code on new & old cables and dropwires. 3. Avoid low sagging cable below 18 feet from ground level. REQUESTED BY: To be accomplished by TIELCO Cable Attachment MR. JAIME R. REMO PLDT-SLZ FPM-Coordinator/Date (signature over printed name) Page (2) of 2 RTA Form of PROGRESO ESTE ( TUQUIS ODIONGAN ROMBLON.xls Cable Attachment Existing RTA Inventory New Attachment Approved Disapproved Alley Arm Existing For Installation Type P/C Size TIELCO Rep./Date Legend REMARKS TIELCO Rep./Date