IEC 60027-7 ® Edition 1.0 2010-05 INTERNATIONAL STANDARD Letter symbols to be used in electrical technology – Part 7: Power generation, transmission, and distribution IEC 60027-7:2010 Symboles littéraux à utiliser en électrotechnique – Partie 7: Production, transport et distribution de l’énergie électrique LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. NORME INTERNATIONALE THIS PUBLICATION IS COPYRIGHT PROTECTED Copyright © 2010 IEC, Geneva, Switzerland All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or IEC's member National Committee in the country of the requester. If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local IEC member National Committee for further information. Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur. Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence. About the IEC The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes International Standards for all electrical, electronic and related technologies. About IEC publications The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the latest edition, a corrigenda or an amendment might have been published. Catalogue of IEC publications: www.iec.ch/searchpub The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…). It also gives information on projects, withdrawn and replaced publications. IEC Just Published: www.iec.ch/online_news/justpub Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available on-line and also by email. Electropedia: www.electropedia.org The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical Vocabulary online. Customer Service Centre: www.iec.ch/webstore/custserv If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service Centre FAQ or contact us: Email: csc@iec.ch Tel.: +41 22 919 02 11 Fax: +41 22 919 03 00 A propos de la CEI La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées. A propos des publications CEI Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez l’édition la plus récente, un corrigendum ou amendement peut avoir été publié. Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm Le Catalogue en-ligne de la CEI vous permet d’effectuer des recherches en utilisant différents critères (numéro de référence, texte, comité d’études,…). Il donne aussi des informations sur les projets et les publications retirées ou remplacées. Just Published CEI: www.iec.ch/online_news/justpub Restez informé sur les nouvelles publications de la CEI. Just Published détaille deux fois par mois les nouvelles publications parues. Disponible en-ligne et aussi par email. Electropedia: www.electropedia.org Le premier dictionnaire en ligne au monde de termes électroniques et électriques. Il contient plus de 20 000 termes et définitions en anglais et en français, ainsi que les termes équivalents dans les langues additionnelles. Egalement appelé Vocabulaire Electrotechnique International en ligne. Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du Service clients ou contactez-nous: Email: csc@iec.ch Tél.: +41 22 919 02 11 Fax: +41 22 919 03 00 LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. IEC Central Office 3, rue de Varembé CH-1211 Geneva 20 Switzerland Email: inmail@iec.ch Web: www.iec.ch IEC 60027-7 ® Edition 1.0 2010-05 INTERNATIONAL STANDARD LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. NORME INTERNATIONALE Letter symbols to be used in electrical technology – Part 7: Power generation, transmission, and distribution Symboles littéraux à utiliser en électrotechnique – Partie 7: Production, transport et distribution de l’énergie électrique INTERNATIONAL ELECTROTECHNICAL COMMISSION COMMISSION ELECTROTECHNIQUE INTERNATIONALE PRICE CODE CODE PRIX ICS 01.060 ® Registered trademark of the International Electrotechnical Commission Marque déposée de la Commission Electrotechnique Internationale U ISBN 978-2-88910-921-0 –2– 60027-7 © IEC:2010 CONTENTS FOREWORD...........................................................................................................................3 1 Scope ...............................................................................................................................5 2 Normative references .......................................................................................................5 3 Letter symbols for AC, three-phase AC, and other network quantities ............................... 7 4 Letter symbols for space and time .................................................................................. 17 5 Letter symbols for numerical values and ratios of quantities ........................................... 20 6 Subscripts and superscripts............................................................................................ 24 LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 6.1 Subscripts for natural quantities and components in three-phase AC systems ....... 24 6.2 Subscripts for operating conditions........................................................................ 25 6.3 Subscripts for electrical equipment ........................................................................ 25 6.4 Subscripts for locations, reference points, and fault locations ................................ 27 6.5 Superscripts .......................................................................................................... 28 6.6 Multiple subscripts and their succession ................................................................ 28 Bibliography.......................................................................................................................... 29 60027-7 © IEC:2010 –3– INTERNATIONAL ELECTROTECHNICAL COMMISSION ____________ LETTER SYMBOLS TO BE USED IN ELECTRICAL TECHNOLOGY – Part 7: Power generation, transmission, and distribution FOREWORD 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any services carried out by independent certification bodies. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC 60027-7 has been prepared by IEC technical committee 25: Quantities and units. The text of this standard is based on the following documents: CDV Report on voting 25/391/CDV 25/406/RVC Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table. This publication has been drafted in accordance with the ISO/IEC Directives, Part 2. LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and nongovernmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. –4– 60027-7 © IEC:2010 A list of all parts of the IEC 60027 series, under the general title Letter symbols to be used in electrical technology can be found on the IEC website. The committee has decided that the contents of this publication will remain unchanged until the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data related to the specific publication. At this date, the publication will be • • • • reconfirmed, withdrawn, replaced by a revised edition, or amended. LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 60027-7 © IEC:2010 –5– LETTER SYMBOLS TO BE USED IN ELECTRICAL TECHNOLOGY – Part 7: Power generation, transmission, and distribution 1 Scope This part of IEC 60027 is applicable to generation, transmission, and distribution of electric energy. It gives names and letter symbols for quantities and units. In addition, rules for multiple subscripts and their succession are given. Guidance on the use of capital and lower case letters, is given in IEC 60027-1, 2.1, and guidance on the representation of complex quantities,is given in IEC 60027-1, 1.6. Therefore in many cases only U is given instead of U, U = U or u . 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60027-1:1992, Letter symbols to be used in electrical technology – Part 1: General Amendment 1:1997 Amendment 2:2005 IEC 60027-2:2005, Letter symbols to be used in electrical technology – Part 2: Telecommunications and electronics IEC 60038:2009, IEC standard voltages IEC 60050-121:1998, tism International Electrotechnical Vocabulary – Part 121: Electromagne- Amendment 1 (2002) IEC 60050-131:2002, International Electrotechnical Vocabulary – Part 131: Circuit theory Amendment 1 (2008) IEC 60050-141:2004, systems and circuits International Electrotechnical Vocabulary – Part 141: Polyphase IEC 60050-151:2001, magnetic devices International Electrotechnical Vocabulary – Part 151: Electrical and IEC 60050-195:1998, International Electrotechnical Vocabulary – Part 195: Earthing and protection against electric shock Amendment 1 (1998) LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. This part of IEC 60027 is an addition to IEC 60027-1. Therefore letter symbols already given in IEC 60027-1 are repeated only if they have a special meaning in the field of power generation, transmission, and distribution or if they are used in this field with special subscripts. 60027-7 © IEC:2010 –6– IEC 60050-411:1996, machines International Electrotechnical Vocabulary – Chapter 411: Rotating Amendment 1 (2007) IEC 60050-421:1990, formers and reactors International Electrotechnical Vocabulary – Chapter 421: Power trans- IEC 60050-441:1984, International Electrotechnical Vocabulary – Chapter 441: Switchgear, controlgear and fuses Amendment 1 (2000) International Electrotechnical Vocabulary – Part 442: Electrical IEC 60050-448:1995, system protection International Electrotechnical Vocabulary – Chapter IEC 60050-466:1990, lines International Electrotechnical Vocabulary – Chapter 466: Overhead 448: Power IEC 60050-601:1985, International Electrotechnical Vocabulary – Chapter 601: Generation, transmission and distribution of electricity – General Amendment 1 (1998) IEC 60050-603:1986, International Electrotechnical Vocabulary – Chapter 603: Generation, transmission and distribution of electricity – Power system planning and management Amendment 1 (1998) IEC 60050-604:1987, International Electrotechnical Vocabulary – Chapter 604: Generation, transmission and distribution of electricity – Operation Amendment 1 (1998) IEC 60050-811:1991, traction IEC 60909-0:2001, currents International Electrotechnical Vocabulary – Chapter 811: Electric Short-circuit currents in three-phase AC systems – Part 0: Calculation of IEC/TR 60909-1:2002, Short-circuit currents in three-phase AC systems – Part 1: Factors for the calculation of short-circuit currents according to IEC 60909-0 IEC/TR 60909-2:2008, Short-circuit currents in three-phase AC systems – Part 2: Data of electrical equipment for short-circuit current calculations IEC 60909-3:2003, Short-circuit currents in three-phase AC systems – Part 3:Currents during two separate simultaneous line-to-earth short circuits and partial short-circuit currents flowing through earth IEC 62428:2008, Electric power engineering – Modal components in three-phase a.c. systems – Quantities and transformations IEC 80000-6:2008, Quantities and units – Part 6: Electromagnetism LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. IEC 60050-442:1998, accessories prospective breaking current, breaking current 441-17-06 441-17-07 105 direct current 131-11-22 442-01-23 108 109 110 capacitive earth-fault current 107 field (excitation) current earth fault current capacitive charging current 106 60909-0 electric current 104 60027-2 hybrid matrix 103 131-14-29 line-to-line capacitance of a line 102 Name of quantity line-to-earth capacitance of a line IEV and/or IEC number 101 Item number IF Ie Id I Ce IC Ib I H C LiLk C Li Chief symbol If I DC Ia C Lik C LiE Reserve symbol Quantities Remarks DC , see IEC 60050-151, Current in the field winding of a machine. See items 107 and 121. For the qualifier 151-15-02 average value, for instance in the case of a direct current link current in a network with isolated neutral (IEV 601-02-24). I Ce is the capacitive single line-to-earth fault three-phase AC line. U IC = ω C n where ω is the angular 3 frequency, C is the positive-sequence capacity, and U n is the nominal voltage of the Current of the first opening pole of a switching device (circuit breaker) or a fuse. The general symbol I is used in case of threephase AC networks if the three currents are equal or nearly equal. Names and symbols for the elements are given in IEC 60027-2. networks i, k = 1, 2, 3 with i ≠ k in three-phase AC i = 1, 2, 3 in three-phase AC networks Letter symbols for AC, three-phase AC, and other network quantities A A A A A A A ampere ampere ampere ampere ampere ampere ampere siemens 1, Ω, F farad one, ohm, F farad Units S Symbol Unit, coherent with the SI Name LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 3 Remarks 60027-7 © IEC:2010 –7– 60909-0 121-11-13 MOD 411-48-16 114 115 116 119 thermal continuous permissible current peak short-circuit current at a short-circuit location 118 60909-0 magnetizing current 117 locked rotor current line conductor current subtransient short-circuit current at a short-circuit location I per ip Im I LR I Li Ik" Ik' Ik I 0F Chief symbol Id i p3 Iμ I an " Ik3 Ik' 3 I k3 I f0 Reserve symbol The peak short circuit current is the maximum possible instantaneous value of the prospective three-phase short-circuit current. I m is the magnetizing current of a machine, a reactor, a transformer, etc. IEC 60027-1, Table 6, Subscript m, mag. asynchronous motor with locked rotor at the most unfavourable postion fed with rated voltage and frequency of the rotor. I LR is the highest r.m.s. current of an i = 1, 2, 3 in three-phase AC networks. The initial symmetrical short-circuit current at a short-circuit location is the r.m.s. value of the AC component of a prospective threephase short-circuit current. The transient short circuit current is the r.m.s. value of a three-phase short-circuit current at a short-circuit location after the decay of the subtransient short-circuit current. Short-circuit currents with subscript k in solidly earthed or impedance earthed networks (IEV 601-02-25, IEV 601-02-26). The steady state short-circuit current in the r.m.s. value of a three-phase short-circuit current at a short-circuit location in a network, which remains after the decay of all transient phenomena. Remarks A A A A A A A A A ampere ampere ampere ampere ampere ampere ampere ampere ampere Units Symbol Unit, coherent with the SI Name LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 60909-0 60909-1 113 transient short-circuit current at a short-circuit location steady-state short-circuit current at a short-circuit location 60909-0 112 Name of quantity no-load field (excitation) current IEV and/or IEC number 111 Item number Quantities Remarks –8– 60027-7 © IEC:2010 60909-0 124 448-11-30 127 128 rated current at the high-voltage side of a transformer 60909-0 126 rated current of a winding inrush current earth-fault residual current 125 rated current of a generator rated field (excitation) current 411-54-07 123 rated current rated current of a current transformer 421-04-05 121 peak short-circuit current of a generator Name of quantity 122 411-48-23 MOD 120 IEV and/or IEC number I rW , I rw Irush I rTHV I rsd I rG I rF I rCT Ir i pG Chief symbol I Rest I fr Reserve symbol In the case of three-winding transformers, see item 253. Transformer winding at the high-voltage side (W) or the low-voltage side (w). Inrush current of a transformer. Use I rTMV and I rTLV , respectively, at the medium-voltage and the low-voltage side. Current at the fault location of a resonant earthed network (see IEV 601-02-27) Rated current, given from the manufacturer of electrical equipment, for a generator, motor, transformer, reactor, etc. If necessary with an additional subscript from 6.3. Peak value reached by the current in the armature winding within a half cycle after the winding has been suddenly short circuited, when the conditions are such that the initial value of any aperiodic component of current is a maximum. Remarks A A A A A A A A A ampere ampere ampere ampere ampere ampere ampere ampere ampere Units Symbol Unit, coherent with the SI Name LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. Item number Quantities Remarks 60027-7 © IEC:2010 –9– dielectric loss 121-12-11 136 active power 134 DC power harmonic current component 133 135 winding current 132 131-11-42 currents at the terminals of the tertiary winding of a three-phase AC transformer 131 thermal equivalent short-circuit current Name of quantity currents at the terminals of threephase AC transformers with two windings 60909-0 IEV and/or IEC number P diel Pd P Iν IW i , I wi I x, I y , I z Iu, Iv, I w I U, I V, IW I th Chief symbol Pε PDC Reserve symbol = (2), 3, (4), 5, ... ≠ 1; fν = ν f where U d is the line-to-line voltage of of a SCline (item 149) and I d the DC-current at the same location (item 108). Pd = U d I d , P = 3UI cos ϕ In a three-phase AC network with symmetric sinusoidal voltages and currents: ν For instance index W for the high-voltage side and index w for the low-voltage side (see item 252). i = 1, 2, 3 in three-phase AC networks The subscripts x, y, z should be used in case of transformer windings in delta connection. Subscripts for the low-voltage side: u, v, w Subscripts for the high-voltage side: U, V, W (thermal) effect of the DC component in a short-circuit current (item 229), and n the factor for the (thermal) effect of the AC component in a short-circuit current (item 232). I k′′ is the subtransient short-circuit current (item 113), m is the factor for the heat where r.m.s. value of a current having the same thermal effect and the same duration as the actual short-circuit current, which may contain a DC component and may subside in time, I th = Ik" m + n , Remarks A A A ampere ampere ampere watt watt W W W A ampere watt A ampere Units Symbol Unit, coherent with the SI Name LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 130 129 Item number Quantities In practice mostly in kW or MW Is used. Remarks – 10 – 60027-7 © IEC:2010 80000-6, 6-61 non-active power 140 131-11-43 rated mechanical power of a motor 139 total load loss in transformer windings at rated current surge-impedance load of a line 421-06-03 MOD Name of quantity 138 137 IEV and/or IEC number Q ~ , Q′ P rM P nat P krT Chief symbol Reserve symbol the phase difference and S 2 − P2 ηrM where S is the apparent power (item 142) und P the active power (item 134) Q~ = the efficiency of the motor. ϕrM U rM is the rated voltage, IrM the rated current, where PrM = 3U rM IrM cos ϕrMηrM For a three-phase asynchronous motor use: where U n is the nominal value of the line-toline voltage (item 159) and Z W = ZW 1 is the surge impedance of a line in the positivesequence system (item 186). Pnat = U n2 / Z W Surge-impedance load of a three-phase AC line in case of U n In case of three-winding transformers three measurements or calculations are necessary (see IEC 60909-0 and IEC 60909-2). In case of a two-winding three-phase transformer (T) one side is short circuited (k) and the other side is fed with the rated current (r) of this side of the main tapping. Remarks Units W VA volt ampere W watt watt W watt Symbol Unit, coherent with the SI Name LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. Item number Quantities Remarks 60027-7 © IEC:2010 – 11 – 601-01-14 MOD 143 121-11-27 195-05-11 147 148 (effective) touch voltage voltage, electric tension transformation matrix 62428 146 short-circuit power of a threephase AC network feeder at the connection point Q rated apparent power 60909-0 short-circuit power apparent power reactive power Name of quantity 145 144 131-11-41 142 60909-0 131-11-44 141 IEV and/or IEC number UB U T Sr " SkQ Sk" S Q Chief symbol Reserve symbol Q = 3UI sin ϕ = S sin ϕ the ϕi as '' IkQ the subtransient indication: line-to-line voltage; line-to-line tension. U is the general symbol, with no further components in the unnormalized form, (see item 256). TS transformation matrix for symmetrical Examples for electrical equipment: S rG , S rT (subscripts in subclause 6.3). short-circuit current at the connection point Q. line-to-line voltage and " " S kQ = 3U nQ I kQ , where U nQ is the nominal subtransient short-circuit current (item 114). '' to-line voltage (item 159) and I k the Sk" = 3U n Ik" , where U n is the nominal line- The short-circuit apparent power in a symmetrical three-phase AC network is given as: voltage (item 147) and (item 104). S = 3UI , where U is the line-to-line I the line current In a symmetrical three-phase AC network use: initial phase of the current (IEC 80000-6, 648). the initial phase of the voltage and ϕu the phase difference with S is the apparent power (item 142) and ϕ = ϕu − ϕi where and currents: Shall be used only in three-phase AC networks with symmetric sinusoidal voltages Remarks VA VA VA VA volt ampere volt ampere volt ampere volt ampere volt volt V V 1 VA volt ampere one Units Symbol Unit, coherent with the SI Name LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. Item number Quantities In practice mostly kVA, MVA is used. In practice mostly MVA Iis used. In practice mostly MVA is used. In practice mostly kVA, MVA is used. In practice mostly var, kvar, Mvar is used. Remarks – 12 – 60027-7 © IEC:2010 195-05-01 141-03-06 195-05-02 421-09-01 154 155 156 601-01-32 442-01-04 601-01-21 411-49-02 159 160 601-01-24 601-01-23 158 157 195-05-03 153 synchronous generated voltage nominal voltage of a line nominal voltage of a system nominal voltage of a network neutral point or neutral conductor to-earth voltage highest and lowest voltage of a network highest voltage for equipment line-to-neutral voltage line-to-line voltage UP Un U NE U min U max Um U LiN U LiLk U Li U Fmax UF UE Ud Chief symbol Up U Nmin U Nmax U Lik U LiE U fmax Uf U DC Reserve symbol volt i =1, 2, 3 in three-phase AC systems with a neutral conductor (low-voltage networks) Voltage, which would be generated in the armature windings on open circuit, in the absence of saturation, by the flux corresponding to the excitation current for the conditions under consideration. The nominal voltage of a network is always a line-to-line voltage. IEV: Neutral point displacement voltage. IEV. Highest (lowest) voltage of a network. volt volt volt volt volt volt i, k = 1, 2, 3 with i ≠ k in three-phase AC networks The highest r.m.s. line to-line voltage permanently admissible for equipment. volt volt volt volt volt V V V V V V V V V V V V Units Symbol Unit, coherent with the SI Name i =1,2,3 in three-phase AC networks. Voltage at the field winding of a machine. For the qualifier DC, see IEC 60050, 151-15-02. Average value, for instance in case of a direct current link. Remarks LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 60038 excitation system ceiling voltage 411-54-06 152 line-to-earth voltage field voltage, excitation voltage 151 earthing potential 60909-3 150 Name of quantity direct voltage, direct tension IEV and/or IEC number 149 Item number Quantities Remarks 60027-7 © IEC:2010 – 13 – 411-54-08 421-04-01 195-05-12 131-12-22 411-49-13 411-49-14 411-49-11 411-49-12 411-50-07 411-50-08 411-50-09 411-50-10 411-50-11 162 163 164 165 166 167 168 169 170 171 172 173 174 60909-0 442-01-03 MOD 161 IEV and/or IEC number direct-axis subtransient reactance quadrature-axis transient reactance direct-axis transient reactance quadrature-axis synchronous reactance direct-axis synchronous reactance quadrature-axis subtransient voltage direct-axis subtransient voltage quadrature-axis transient voltage direct-axis transient voltage source voltage, source tension step voltage rated voltage of a winding rated field voltage rated voltage Name of quantity X "d X q' X d' Xq Xd X d" shall be used. synchronous machine at the moment of threephase short circuit. For the calculation of short-circuit currents the saturated value of V Ω Ω Ω Ω Ω ohm ohm ohm ohm ohm V V V V V V V V volt volt U "d U "q volt volt volt volt volt volt Units Symbol Unit, coherent with the SI Name U 'q X d" i s the effective reactance of a See also item 128. See subclause 6.6. Line-to-line-voltage of electrical equipment, generator, motor, transformer, reactor, etc., if necessary with an additional index from 6.3 Remarks volt Uq U Step U fr Reserve symbol U d' Us US U rW , U rw U rF Ur Chief symbol LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. Item number Quantities Remarks – 14 – 60027-7 © IEC:2010 admittance matrix 179 admittance of the positive sequence system of a line per Length admittance of the negativesequence system of a line per length impedance matrix 131-14-24 60909-0 181 182 183 184 surge impedance of a line in the positive sequence system 603-02-23 448-11-29 MOD 448-11-27 MOD 186 187 188 Remarks Z 1' = R1' + jω L1' Z1' Z W1 = Z 1' / Y 1' Z W0 = Z '0 / Y 0' Z "G = RG + jX d" Names and symbols for the elements are given in IEC 60027-2. Y '2 = G2' + jω C2' Y 1' = G1' + jω C1' Y 0' = G0' + jω C0' Names and symbols for the elements are given in IEC 60027-2. Z '0 = R0' + jω L'0 ZW A Xl Reserve symbol Z0' ZW 1 ZW 0 " ZG Z Y2' Y1' Y0' Y Xσ Xs Xm X q" Chief symbol Ω Ω Ω S ohm ohm ohm siemens Ω Ω ohm ohm per metre ohm per metre Ω/m Ω/m Ω ohm ohm Ω S/m S/m ohm per metre siemens per metre siemens per metre S/m Ω ohm siemens Units Symbol Unit, coherent with the SI Name LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. positive-sequence impedance of a line per length zero-sequence impedance of a line per length surge impedance of a line in the zero sequence system 185 subtransient impedance of a generator admittance of the zero sequence system of a line per length 180 60027-2 leakage reactance 178 131-14-25 self reactance 177 quadrature-axis subtransient reactance Name of quantity mutual reactance 411-50-12 IEV and/or IEC number 176 175 Item number Quantities In practice often Ω/km is used. In practice often Ω/km is used. Remarks 60027-7 © IEC:2010 – 15 – load angle angle between earth penetration depth 60909-3 60909-3 192 193 194 195 specific earth resistance U i and U k impedance angle 191 negative-sequence impedance of a line per length admittance angle 448-11-28 MOD Name of quantity 190 189 IEV and/or IEC number ρE δE δ ik δP ϑik = arctan( X / T ) for Z = R + jX δ E = 1,8514 / ωμ 0 / ρ E (item 195). where ω is the angular frequency, μ 0 the magnetic constant (IEC 60050-121, 121-11-14) and ρE the earth resistivity length of line is , U 1G and Earth penetration depth in case of infinite δ ik = ϕ ui − ϕ uk U P of a synchronous machine. Load angle is the angle between γ γ Y = G + jB Remarks = arctan( B / G ) for Z '2 = R2' + jω L'2 α ϑ Reserve symbol α Z 2' Chief symbol rad rad rad rad m Ωm radian radian radian metre ohm metre Ω/m radian per metre ohm Units Symbol Unit, coherent with the SI Name LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. Item number Quantities In practice often Ω/km is used. Remarks – 16 – 60027-7 © IEC:2010 effective height above ground of a line-conductor from an overhead line line length cross-section radius equivalent radius of a bundle conductor 202 203 204 205 206 60909-0 inertia constant 201 eigenfrequency 200 702-01-07 MOD sag of a line-conductor of an overhead line 199 line-to-earth clearance 198 466-05-13 MOD distance 197 Name of quantity diameter of a line conductor IEV and/or IEC number 196 Item number Letter symbols for space and time fe rB r q l h H f d LEmin d DL Chief symbol rL A L he a dL Reserve symbol Quantities dLiLk qL where n is the number of sub-conductors; for r L see item 205; for r T see item 207. rB = n n ⋅ rL ⋅ rTn −1 Radius of a line conductor Cross-section of a line-conductor overhead line or cable h = h max – 0,7 f max H = Tm / 2 f e = ω e / 2 π , see item 219 f max maximum value in case of a horizontal span between two towers (mid span sag), see IEV 466-03-09 and its Figure 446-1. Distance between two line conductors: Apparent diameter of a stranded conductor, see IEV 581-03-51 Remarks Units m m m m Hz s m m m2 m m metre metre metre metre hertz second metre metre square metre metre metre Symbol Unit, coherent with the SI Name LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 4 usually in mm 2 usually in km Remarks 60027-7 © IEC:2010 – 17 – 411-48-27 411-48-30 411-48-29 411-48-26 60909-0 211 212 213 214 215 electromechanical time constant quadrature-axis subtransient short-circuit time constant 217 short-circuit duration aperiodic time constant, direct current time constant direct-axis subtransient opencircuit time constant direct-axis subtransient shortcircuit time constant direct-axis transient open-circuit time constant 216 411-48-35 411-48-28 210 direct-axis transient short-circuit time constant expected acceleration duration 411-48-15 MOD 209 radius of the sub-conductors in a bundle distance between the centres of gravity of the surfaces i and k 466-10-24 466-10-23 466-10-22 Name of quantity 208 207 IEV and/or IEC number Tq" Tm Tk Ta " Td0 Td" ' Td0 Td' TA s ik rT Chief symbol T DC Reserve symbol =a/ 2 ; This applies to a synchronous machine. where H is the inertia constant (see item 201 ). Tm = 2 H This applies to a synchronous machine. This applies to a synchronous machine. This applies to a synchronous machine. This applies to a synchronous machine. This applies to a synchronous machine. The duration that would be required to bring the rotating parts of a machine from rest to rated speed if the accelerating torque were constant and equal to the quotient of rated active power by rated angular velocity. where a is the distance between two subconductors. quad bundle: rT =a/ 3; =a/ 2; triple bundle: rT twin bundle: rT Remarks Units m m s s s s s s s s s metre metre second second second second second second second second second Symbol Unit, coherent with the SI Name LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. Item number Quantities Remarks – 18 – 60027-7 © IEC:2010 219 218 60909-0 IEV and/or IEC number angular eigenfrequency minimal time delay Name of quantity ωe t min Chief symbol T k min Reserve symbol with f e according to item 200. ωe = 2π fe This is the shortest duration between the beginning of the short circuit and the contact separation of the first pole to open the switching device. Remarks Units s s –1 second second to the power minus one Symbol Unit, coherent with the SI Name LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. Item number Quantities Remarks 60027-7 © IEC:2010 – 19 – number of nodes number of conductors per bundle 231 factor for the heat (thermal) effect of the DC component in a shortcircuit current 229 230 number of meshes 228 60909-0 number of lines 227 impedance correction factor 225 overvoltage factor factor for the increase of a resistance by the skin-effect 224 226 factor for the increase of a resistance by the proximityeffect 223 60909-0 damping factor 222 voltage factor 60909-0 221 Name of quantity refraction factor IEV and/or IEC number 220 Item number n N m M L k K FS FP d c b Chief symbol Reserve symbol Quantities Remarks U b sometimes U m is used). This applies to high-voltage overhead lines in three-phase AC networks. This applies to three-phase AC networks. See item 129 This applies to three-phase AC networks. This applies to three-phase AC networks. (instead of b: U superscript b, see item 335 u o : subscript o, see item 277; k = uo /( 2U b / 3 ) ; For impedances of electrical equipment when calculating short-circuit currents with the equivalent voltage source at the short-circuit location according to IEC 60909-0. R ~ = FS FP R = R ~ = FS FP R = Factor for the equivalent voltage at the shortcircuit location. For travelling waves on lines, different for voltage and current. Letter symbols for numerical values and ratios of quantities one one one one one one one one one one one one 1 1 1 1 1 1 1 1 1 1 1 1 Units Symbol Unit, coherent with the SI Name LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 5 Remarks – 20 – 60027-7 © IEC:2010 rated voltage ratio of a transformer 241 442-01-03 MOD 436-01-15 MOD voltage ratio of a transformer 240 421-04-02 relative short-circuit impedance of a transformer reduction factor 239 60909-3 236 complex voltage reflection factor relative short-circuit reactance of a transformer 131-15-33 235 complex current reflection factor 238 131-15-32 234 number of pairs of poles relative short-circuit resistance of a transformer 60027-1 233 factor for the heat (thermal) effect of the AC component in a shortcircuit current Name of quantity t rT t zT xT rT r rU rI p n Chief symbol Reserve symbol U rT / 3 and IrT , see also U rT / 3 and IrT , see also U rT / 3 and IrT , see also one one one one one The rated voltage ratio may be different from the turns ratio (item 246). U rTLV the rated voltage at the low-voltage one side of the transformer. rated voltage at the high-voltage side and trT = U rTHV / U rTLV ≥ 1 , where U rTHV is the See item 241. item 242. reference values This is the relative value in the case of a twowinding three-phase AC transformer with item 244. reference values This is the relative value in the case of a twowinding three-phase AC transformer with item 243. reference values This is the relative value in the case of a twowinding three-phase AC transformer with This applies to the case of interference. one one This applies to travelling waves on lines. This applies to travelling waves on lines. one one 1 1 1 1 1 1 1 1 1 1 Units Symbol Unit, coherent with the SI Name This applies to synchronous and asynchronous three-phase AC machines. See item 129 Remarks LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 237 60909-0 IEV and/or IEC number 232 Item number Quantities Remarks 60027-7 © IEC:2010 – 21 – 60909-0 60909-0 248 249 604-03-06 factor for the calculation of the steady-state short-circuit current factor for the calculation of the peak short-circuit current earth fault factor 247 195-05-14 turns ratio reactive component of the related short-circuit voltage of a transformer 246 60909-0 244 resistive component of the related short-circuit voltage of a transformer detuning coefficient 60909-0 243 related short-circuit voltage of a transformer Name of quantity 245 60909-0 242 IEV and/or IEC number λ κ δ w v uX uR uk Chief symbol n Reserve symbol ip 2I k′′ , where ip is the peak short- one one one one one one circuit current of a generator . . IkG the steady-state short- I kG , λ max and λmin , where I rG is the one I rG rated current and λ= For one synchronous machine: subtransient short-circuit current (item 114). '' circuit current (item 118) and I k is the κ = In case of a three-phase AC short circuit: w = WHV / WLV (see IEV 195-04-09). This apllies to a resonant earthed neutral network . u Xr , s ee also item 238, the value of u X is equal to the value of x T For rated value: u Rr , see also item 237 , the value of u R is equal to the value of r T rated value: in practice given in % 1 1 1 1 1 1 in practice given in % in practice given in % Remarks 1 1 Units Symbol Unit, coherent with the SI Name U rT / 3 and IrT , see also one item 239, the value of u k is equal to the value of z T . reference values: u kr (IEV 421-07-01) rated value with the In the case of a two-winding transformer; Remarks LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. Item number Quantities – 22 – 60027-7 © IEC:2010 250 60909-0 IEV and/or IEC number factor for the calculation of the symmetrical short-circuit breaking current Name of quantity μ Chief symbol Reserve symbol Ik" Ib Ib is the breaking current circuit current (item 114). Ik'' the subtransient short- , where (item 105) and μ= Remarks one 1 Units Symbol Unit, coherent with the SI Name LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. Item number Quantities Remarks 60027-7 © IEC:2010 – 23 – 60027-7 © IEC:2010 – 24 – 6 Subscripts and superscripts 6.1 Item number Subscripts for natural quantities and components in three-phase AC systems Meaning Chief symbol Reserve symbol Example of use 251 line conductors L1, L2, L3 U L1 , U L2 , U L3 252 windings W1, W2, W3 IW 1 , IW2 , IW 3 253 windings 1W1, 1W2, 1W3 I1w3 N neutral conductor N 255 source s 256 positive sequence system 1 negative sequence system 2 zero sequence system 0 HV-side 1, 2, 3 at the beginning of the symbol defines the HV-, the MV- and the LVside of a transformer. 1, 2, 3 at the end of the symbol defines the three windings on each of the three sides in case of a three-phase AC transformer. IN Applicable in low-voltage networks. q Us, u s See item 165. (1) U 1 , U (1) Symmetrical components (IEC 62428) (2) (0) U 2 , U (2) U 0 , U (0) ⎡U L1 ⎤ ⎡ 1 ⎢ ⎥ ⎢ 2 ⎢U L2 ⎥ = ⎢a ⎢⎣U L3 ⎥⎦ ⎢ a ⎢⎣ with 1 a a2 a = e j2 π/3 = − 1⎤ ⎡ U ⎤ ⎥ ⎢ 1⎥ 1⎥ ⋅ ⎢U 2 ⎥ ⎥ 1⎥⎦ ⎢⎣U 0 ⎥⎦ 1 1 +j 3 2 2 (1), (2), (0) used in IEC 60909-0. dq0-components 257 direct axis d 258 quadrature axis q 259 Clarke component α 260 Clarke component β 261 space phasor s u s = uα + juβ Space phasor in a non-rotating frame of reference. 262 space phasor r ur = ud + juq Space phasor in a rotating frame of reference. 263 active component P 264 non-active component Q αβ 0 -components LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. I1w2 3W1, 3W2, 3W3 254 Windings of electrical equipment, for instance the windings of a transformer in delta-connection, see item 253. I1w1 2W1, 2W2, 2W3 Remarks 60027-7 © IEC:2010 6.2 Item number – 25 – Subscripts for operating conditions Meaning Chief symbol Reserve symbol Example of use Remarks general a ... z Use lower case letters for any operating condition. 266 actuated a Ia Applicable to a protection device. 267 breaking b Ib Breaking current of a circuit breaker. See item 105. 268 earth fault e I Ce In networks with isolated neutral or resonant earthed neutral. See item 107 and see also item 125. 269 induced in U in Induced voltage. 270 three-phase short circuit k k3 '' Ik, Ik'' , Ik3 In case of a three-phase short circuit the additional subscript 3 is not necessary (IEC 60909-0). See item 112 to 114. 271 ′′ Ik1 line-to-earth short circuit k1 272 line-to-line short circuit k2 ′′ Ik2 IEC 60909-0. 273 line-to-line short circuit with earth connection k2E ′′ ′′ Ik2EL2 ,Ik2EL3 ′′ : current flowing through earth in case IkE2E maximum max 274 IEC 60909 IEV 195-04-12 of a line-to-line short circuit with earth connection (IEC 60909-0). m U max, U m U m: Maximum permissible permanent voltage of electrical equipment. 275 minimum min 276 nominal n nom 277 over o ov 278 peak p 279 rated r 280 saturated sat X d sat 281 thermal th I th 282 no load uo Instantaneous value of an over-voltage. ip See items 118, 120. rat 0 See item 129. I 0M 6.3 Subscripts for electrical equipment Item number Meaning Chief symbol 283 general A ... Z 284 asynchronous motor ASM 285 bundle conductor B 286 current transformer CT Reserve symbol No-load current of a motor. Example of use Remarks U rT2HV Use upper case letters for electrical equipment or parts of electrical equipment IM IM : Induction motor. IEV 466-10-22, IEV 466-10-23, IEV 466-10-24 I CT LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 265 60027-7 © IEC:2010 – 26 – Item number Meaning Chief symbol 287 generator G 288 DC generator G– 289 AC generator G~ 290 three-phase AC generator G3 ~ 291 gas insulated line GIL 292 gas insulated switching station GIS 293 high-voltage DC link HVDC 294 inverter IN 295 overhead line, cable L 296 line conductors L1, L2, L3 I L1 , I L2 , I L3 297 motor M IrM 298 DC motor M– DCM 299 AC motor M~ ACM 300 three-phase AC motor M3 ~ 301 machine MA 302 network N 303 neutral conductor N in low-voltage networks 304 protective conductor PE In low-voltage networks, IEV 195-02-09 305 PENconductor PEN In low-voltage networks, IEV 195-02-12 306 power station PS 307 earth wire Q Reserve symbol Example of use Remarks UrG IEV 151-13-35 G 3 U V W IEV 601-03-06. IEV 601-04-01 IEV 151-13-46 X L′ r MA S reactance per length in the positive ′ sequence system: X L′ = X 1L IEV 151-13-39, electric machine S PS , S S Apparent power at the high-voltage side of the unit transformer of a power station. IEV 603-01-01 dQ1L1 If there are more than one earth wires use: Q1, Q2, ... Q n . 308 reactor R Re 309 rotor R 310 rectifier RF IEV 151-13-45. 311 stator S Stator of an electrical machine or a turbine. IEV 811-14-01 312 sheath or shielding S 313 synchronous generator SG 314 synchronous motor SM Sh, Si I S1 , I S2 , I S3 Example: currents in case of three singlecore cables. LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. P HVDC 60027-7 © IEC:2010 Item number Meaning Chief symbol 315 synchronous machine SMA 316 synchronous phase shifter SPH 317 transformer T 318 unit transformer UT 319 voltage transformer VT 320 winding W – 27 – Reserve symbol Example of use Remarks IEV 151-13-47 SrT BT See items 130,132, 163, 252, 253 U rUTLV U rVT Subscripts for locations, reference points, and fault locations Item number Meaning Chief symbol 321 location of stations A ... Z 322 earth E 323 fault location, short-circuit location F 324 high-voltage side HV OS U rTHV 325 low-voltage side LV NS U rTLV 326 mediumvoltage side MV MS U rTMV 327 neutral point N 328 connection point, pole P K 329 connection point of a network Q Q1, Q2, Qn 330 reference earth RE BE 331 connection points of three-phase AC equipment U, V, W u, v, w 332 star point Y 333 positive, negativeand zerosequence neutral reference 01 Reserve symbol Example of use Remarks station A Location of stations or parts thereof. G G : ground (US usage). " IkF1 UN In case of several fault locations: F1, F2 , F3, ... F n. IEV 601-02-22 MOD, neutral point in a polyline network. IEV 601-03-11, pole of an equipment. ′′ SkQ Example: Short-circuit power at the connection point Q of a network. Generator, motor, transformer, reactor etc. in three-phase AC networks, if necessary with additions. or x, y, z 02 00 UY Common point of two-pole elements (windings) in star connection. In case of symmetrical components according to item 256. LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 6.4 60027-7 © IEC:2010 – 28 – Superscripts Item number Meaning Chief symbol Reserve symbol 334 after a n 335 before b v 336 per length ′ X L′ 337 transient ′ X d′ , Td′ 338 subtransient ′′ X d′′ , Td′′ 339 semi-relative * in front of the symbol ∗ 6.6 Example of use Remarks b IG Current of a generator before a short circuit. XT = ukr SrT Semi-relative quantities are used similarly to per-unit quantities for network calculations. Multiple subscripts and their succession Item Position number Meaning Clause Example (Remarks) 340 1 natural quantity or modal component 6.2 U 1 (positive sequence system) 341 2 operating condition 6.2 U 1k1 (during a line-to-earth short circuit) 342 3 electrical equipment 6.3 U 1k1T4 (at the fourth transformer) 343 4 location 6.4 U 1k1T4 344 5 additional indication ― U 1k1T4HVmax (highest value) HV (on the high-voltage side) U 1k1T4HVmax : Highest voltage in the positive sequence system, during a line-to-earth short circuit, at the high-voltage side of transformer number four. If necessary, insert a small space between the different subscripts. LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 6.5 – 29 – 60027-7 © IEC:2010 Bibliography IEC 60050 (all parts), International Electrotechnical Vocabulary _____________ LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. – 30 – 60027-7 © CEI:2010 SOMMAIRE AVANT-PROPOS .................................................................................................................. 31 1 Domaine d'application .................................................................................................... 33 2 Références normatives ................................................................................................... 33 3 Symboles littéraux pour les grandeurs alternatives et triphasées et d'autres grandeurs de réseau ...................................................................................................... 36 4 Symboles littéraux pour l'espace et le temps .................................................................. 45 5 Symboles littéraux pour les valeurs numériques et les rapports de grandeurs ................ 47 6 Indices et exposants ....................................................................................................... 51 Indices pour les grandeurs naturelles et les composantes dans les systèmes alternatifs triphasés ............................................................................................... 51 6.2 Indices pour les conditions de fonctionnement....................................................... 52 6.3 Indices pour les appareils électriques .................................................................... 52 6.4 Indices pour les emplacements, les points de références et la localisation des défauts ........................................................................................................... 54 6.5 Exposants ............................................................................................................. 55 6.6 Indices multiples et leur succession ...................................................................... 55 Bibliographie......................................................................................................................... 56 LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 6.1 60027-7 © CEI:2010 – 31 – COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE ____________ SYMBOLES LITTÉRAUX À UTILISER EN ÉLECTROTECHNIQUE – Partie 7: Production, transport et distribution de l’énergie électrique AVANT-PROPOS 2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux de la CEI intéressés sont représentés dans chaque comité d’études. 3) Les Publications de la CEI se présentent sous la forme de recommandations internationales et sont agréées comme telles par les Comités nationaux de la CEI. Tous les efforts raisonnables sont entrepris afin que la CEI s'assure de l'exactitude du contenu technique de ses publications; la CEI ne peut pas être tenue responsable de l'éventuelle mauvaise utilisation ou interprétation qui en est faite par un quelconque utilisateur final. 4) Dans le but d'encourager l'uniformité internationale, les Comités nationaux de la CEI s'engagent, dans toute la mesure possible, à appliquer de façon transparente les Publications de la CEI dans leurs publications nationales et régionales. Toutes divergences entre toutes Publications de la CEI et toutes publications nationales ou régionales correspondantes doivent être indiquées en termes clairs dans ces dernières. 5) La CEI elle-même ne fournit aucune attestation de conformité. Des organismes de certification indépendants fournissent des services d'évaluation de conformité et, dans certains secteurs, accèdent aux marques de conformité de la CEI. La CEI n'est responsable d'aucun des services effectués par les organismes de certification indépendants. 6) Tous les utilisateurs doivent s'assurer qu'ils sont en possession de la dernière édition de cette publication. 7) Aucune responsabilité ne doit être imputée à la CEI, à ses administrateurs, employés, auxiliaires ou mandataires, y compris ses experts particuliers et les membres de ses comités d'études et des Comités nationaux de la CEI, pour tout préjudice causé en cas de dommages corporels et matériels, ou de tout autre dommage de quelque nature que ce soit, directe ou indirecte, ou pour supporter les coûts (y compris les frais de justice) et les dépenses découlant de la publication ou de l'utilisation de cette Publication de la CEI ou de toute autre Publication de la CEI, ou au crédit qui lui est accordé. 8) L'attention est attirée sur les références normatives citées dans cette publication. L'utilisation de publications référencées est obligatoire pour une application correcte de la présente publication. 9) L’attention est attirée sur le fait que certains des éléments de la présente Publication de la CEI peuvent faire l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence. La Norme internationale CEI 60027-7 a été établie par le comité d'études 25 de la CEI: Grandeurs et unités. Le texte de cette norme est issu des documents suivants: CDV Rapport de vote 25/391/CDV 25/406/RVC Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant abouti à l'approbation de cette norme. Cette publication a été rédigée selon les Directives ISO/CEI, Partie 2. LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 1) La Commission Electrotechnique Internationale (CEI) est une organisation mondiale de normalisation composée de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a pour objet de favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de l'électricité et de l'électronique. A cet effet, la CEI – entre autres activités – publie des Normes internationales, des Spécifications techniques, des Rapports techniques, des Spécifications accessibles au public (PAS) et des Guides (ci-après dénommés "Publication(s) de la CEI"). Leur élaboration est confiée à des comités d'études, aux travaux desquels tout Comité national intéressé par le sujet traité peut participer. Les organisations internationales, gouvernementales et non gouvernementales, en liaison avec la CEI, participent également aux travaux. La CEI collabore étroitement avec l'Organisation Internationale de Normalisation (ISO), selon des conditions fixées par accord entre les deux organisations. – 32 – 60027-7 © CEI:2010 Une liste de toutes les parties de la série CEI 60027, sous le titre général Symboles littéraux à utiliser en électrotechnique, peut être trouvée sur le site internet de la CEI. Le comité a décidé que le contenu de cette publication ne sera pas modifié avant la date de stabilité indiquée sur le site web de la CEI sous "http://webstore.iec.ch" dans les données relatives à la publication recherchée. A cette date, la publication sera • • • • reconduite, supprimée, remplacée par une édition révisée, ou amendée. LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 60027-7 © CEI:2010 – 33 – SYMBOLES LITTÉRAUX À UTILISER EN ÉLECTROTECHNIQUE – Partie 7: Production, transport et distribution de l’énergie électrique 1 Domaine d'application Cette partie de la CEI 60027 s’applique à la production, au transport et à la distribution de l’énergie électrique. Elle donne les noms et les symboles littéraux des grandeurs et unités. Elle fixe en outre des règles concernant les indices multiples et leur succession. La CEI 60027-1:1992 donne en 2.1 des conseils concernant l'emploi des lettres majuscules et minuscules et en 1.6 des conseils concernant la représentation des grandeurs complexes. Dans de nombreux cas, on indique donc seulement U au lieu de U, U = U ou u . 2 Références normatives Les documents de référence suivants sont indispensables pour l’application du présent document. Pour les références datées, seule l’édition citée s’applique. Pour les références non datées, la dernière édition du document de référence s’applique (y compris les éventuels amendements). CEI 60027-1:1992, Symboles littéraux à utiliser en électrotechnique – Partie 1: Généralités Amendement 1:1997 Amendement 2:2005 CEI 60027-2:2005, Symboles littéraux Télécommunications et électronique CEI 60038:2009, à utiliser en électrotechnique – Partie 2: Tensions normales de la CEI CEI 60050-121:1998, magnétisme Vocabulaire Electrotechnique International – Partie 121: Electro- Amendement 1 (2002) CEI 60050-131:2002, circuits Vocabulaire Electrotechnique International – Partie 131: Théorie des Amendement 1 (2008) CEI 60050-141:2004, circuits polyphasés Vocabulaire Electrotechnique International – Partie 141: Systèmes et CEI 60050-151:2001, Vocabulaire Electrotechnique International – Partie 151: Dispositifs électriques et magnétiques LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. Cette partie de la CEI 60027 est une extension de la CEI 60027-1. Les symboles littéraux figurant déjà dans la CEI 60027-1 ne sont donc répétés que s’ils ont une signification particulière dans le domaine de la production, du transport et de la distribution de l’énergie électrique ou s’ils sont utilisés avec des indices particuliers dans ce domaine. – 34 – 60027-7 © CEI:2010 CEI 60050-195:1998, Vocabulaire Electrotechnique International – Partie 195: Mise à la terre et protection contre les chocs électriques Amendement 1 (2001) CEI 60050-411:1996, tournantes Vocabulaire Electrotechnique International – Chapitre 411: Machines Amendement 1 (2007) CEI 60050-421:1990, Vocabulaire Electrotechnique International – Chapitre 421: Transformateurs de puissance et bobines d’inductance CEI 60050-441:1984, reillage et fusibles Vocabulaire Electrotechnique International – Chapitre 441: Appa- CEI 60050-442:1998, reillage Vocabulaire Electrotechnique International – Partie 442: Petit appa- CEI 60050-448:1995, des réseaux d’énergie Vocabulaire Electrotechnique International – Chapitre 448: Protection CEI 60050-466:1990, électriques Vocabulaire Electrotechnique International – Chapitre 466: Lignes CEI 60050-601:1985, Vocabulaire Electrotechnique International – Chapitre 601: Production, transport et distribution de l’énergie électrique – Génàralités Amendement 1 (1998) CEI 60050-603:1986, Vocabulaire Electrotechnique International – Chapitre 603: Production, transport et distribution de l’énergie électrique – Planification et conduite des réseaux Amendement 1 (1998) CEI 60050-604:1987, Vocabulaire Electrotechnique International – Chapitre 604: Production, transport et distribution de l’énergie électrique – Exploitation Amendement 1 (1998) CEI 60050-811:1991, électrique Vocabulaire Electrotechnique International – Chapitre 811: Traction CEI 60909-0:2001, Courants de court-circuit dans les réseaux triphasés à courant alternatif – Partie 0: Calcul des courants CEI/TR 60909-1:2002, Courants de court-circuit dans les réseaux triphasés à courant alternatif – Partie 1: Facteurs pour le calcul des courants de court-circuit conformément à la CEI 60909-0 CEI/TR 60909-2:2008, Short-circuit currents in three-phase AC systems – Part 2: Data of electrical equipment for short-circuit current calculations Disponible en anglais seulement. CEI 60909-3:2003, Courants de court-circuit dans les réseaux triphasés à courant alternatif – Partie 3: Courants durant deux courts-circuits monophasés simultanés séparés à la terre et courants de court-circuit partiels s’écoulant à travers la terre LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. Amendement 1 (2000) 60027-7 © CEI:2010 – 35 – CEI 62428:2008, Energie électrique – Composantes modales dans les systèmes a.c. triphasés – Grandeurs et transformations CEI 80000-6:2008, Grandeurs et unités – Partie 6: Electromagnétisme LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. matrice hybride courant coupé 441-17-07 courant capacitif de défaut à la terre courant continu 131-11-22 442-01-23 107 108 109 courant d’excitation courant d’excitation à vide 110 111 courant de défaut à la terre courant de charge capacitif IF0 IF Ie Id I Ce I f0 If IDC Ia C L ik CLiE Symbole de réserve 3 Un , où ω Courant dans l’enroulement d’excitation d’une machine. Voir les numéros 107 et 121. Pour le qualificatif DC, voir la CEI 60050-151. valeur moyenne, par exemple dans le cas d’une liaison à courant continu phase-terre dans un réseau à neutre isolé (VEI 601-02-24). I Ce est le courant capacitif de défaut nominale de la ligne alternative triphasée. U n la tension est la pulsation, C la capacité du système direct et IC = ω C Courant dans le premier pôle ouvrant d’un appareil de connexion (disjoncteur) ou dans un fusible. Le symbole général I est utilisé dans le cas de réseaux alternatifs triphasés pour lesquels les trois courants sont égaux ou approximativement égaux. Les noms et les symboles des éléments sont donnés dans la CEI 60027-2. alternatifs triphasés i , k = 1, 2, 3 avec i ≠ k dans les réseaux i = 1, 2, 3 dans les réseaux alternatifs triphasés Observations Unités A A A A A A A A ampère ampère ampère ampère ampère ampère ampère ampère siemens 1, F farad un, ohm, F Ω, S Symbole farad Nom Unité cohérente avec le SI LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 106 IC Ib courant coupé présumé, 441-17-06 105 60909-0 I courant électrique H CLiL k CLi Symbole principal 104 60027-2 103 131-14-29 capacité entre phases d’une ligne Nom de la grandeur 102 Numéro VEI et/ou CEI capacité phase-terre d’une ligne N° Grandeurs Symboles littéraux pour les grandeurs alternatives et triphasées et d'autres grandeurs de réseau 101 3 Observations – 36 – 60027-7 © CEI:2010 60909-1 60909-0 121-11-13 MOD 411-48-16 113 114 115 116 119 courant thermiquement admissible en régime continu courant de court-circuit de crête à l’endroit du court-circuit 118 60909-0 courant d'aimantation courant à rotor bloqué courant d’un conducteur de ligne courant de court-circuit subtransitoire à l’endroit du courtcircuit courant de court-circuit transitoire à l’endroit du court-circuit courant de court-circuit permanent à l’endroit du courtcircuit Nom de la grandeur Iper ip Im ILR ILi Ik" Ik' Ik Symbole principal Id ip3 Iμ I an " Ik3 ' Ik3 Ik3 Symbole de réserve A A A A A A A ampère ampère ampère ampère ampère ampère Le courant de court-circuit symétrique initial à l'endroit d'un court-circuit est la valeur efficace de la composante alternative d’un courant de court-circuit triphasé présumé. i = 1, 2, 3 dans les réseaux alternatifs triphasés. Symbole ampère Nom A Le courant de court-circuit de crête est la valeur instantanée maximale possible d’un courant de court-circuit triphasé présumé. machine, d'une bobine d'inductance, d'un transformateur, etc. CEI 60027-1, Tableau 6, indices: m, mag. Im est le courant d’aimantation d'une moteur asynchrone alimenté à la tension assignée et à la fréquence assignée du rotor, le rotor étant bloqué dans la position la plus défavorable. ILR est le plus grand courant efficace d’un Le courant de court-circuit transitoire est la valeur efficace d’un courant de court-circuit triphasé à l’endroit où se produit le courtcircuit, après amortissement du courant de court-circuit subtransitoire. Courants de court-circuit d’indice k dans les réseaux à neutre mis à la terre directement ou par impédance (VEI 601-02-25, VEI 60102-26). Le courant de court-circuit permanent est la valeur efficace d’un courant de court-circuit triphasé à l’endroit du réseau où se produit le court-circuit, après amortissement de tous les phénomènes transitoires. Unités Unité cohérente avec le SI ampère Observations LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 117 60909-0 60909-0 Numéro VEI et/ou CEI 112 N° Grandeurs Observations 60027-7 © CEI:2010 – 37 – 60909-0 124 448-11-30 127 128 courant assigné du côté haute tension d’un transformateur 60909-0 126 courant assigné d’un enroulement courant d’appel courant résiduel terre-défaut 125 courant assigné d’une génératrice courant d’excitation assigné 411-54-07 123 courant assigné courant assigné d’un transformateur de courant 421-04-05 121 courant de court-circuit de crête d’une génératrice Nom de la grandeur 122 411-48-23 MOD 120 Numéro VEI et/ou CEI IrW , Irw Irush IrTHV Irsd IrG IrF IrCT Ir ipG Symbole principal IRest Irf Symbole de réserve (W) pour l'enroulement haute tension d’un transformateur ou (w) pour l'enroulement basse tension. Voir n° 253 pour les transformateurs à trois enroulements. Courant d’appel d’un transformateur. Utiliser respectivement I rTMV et I rTLV du côté moyenne tension et du côté basse tension. Courant à l’endroit d'un défaut d’un réseau compensé par bobine d’extinction (voir VEI 601-02-27). Le courant assigné est indiqué par le fabricant de matériel électrique pour une génératrice, un moteur, un transformateur, une inductance, etc.; si nécessaire, utiliser un indice supplémentaire d'après 6.3. Valeur de crête atteinte par le courant dans un enroulement d’induit durant la demipériode suivant un court-circuit brusque de l’enroulement, sous la condition que la valeur initiale de chaque composante apériodique du courant est maximale. Observations Unités A A A A A A A A A ampère ampère ampère ampère ampère ampère ampère ampère Symbole ampère Nom Unité cohérente avec le SI LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. N° Grandeurs Observations – 38 – 60027-7 © CEI:2010 pertes diélectriques 121-12-11 136 puissance active 134 puissance continue composante harmonique de courant 133 135 courant d’enroulement 132 131-11-42 courants aux bornes de l’enroulement tertiaire d’un transformateur alternatif triphasé 131 courant de court-circuit équivalent thermique Nom de la grandeur courants aux bornes des transformateurs alternatifs triphasés à deux enroulements 60909-0 Numéro VEI et/ou CEI Pdiel Pd P Iv I W i , I wi Ix , Iy , Iz Iu , I v , I w IU , I V , I W I th Symbole principal Pε PDC Symbole de réserve Ik'' est le courant de court-circuit ≠ 1; fν = ν f P = 3UI cos ϕ même endroit. conducteurs d'une ligne supraconductrice (n° 149) et I d le courant continu (n° 108) au Pd = U d I d , où U d est la tension entre symétriques: Dans un réseau alternatif triphasé siège de tensions et de courants sinusoïdaux ν = (2), 3, (4), 5 ... Par exemple indice W du côté haute tension et w du côté basse tension (voir n° 252). triphasés. i = 1,2,3 dans les réseaux alternatifs Il convient d'utiliser les indices x, y, z dans le cas d'enroulements à couplage en triangle. Indices u, v, w pour le côté basse tension Indices U, V, W pour le côté haute tension subtransitoire (n° 113), m est le facteur d'effet thermique de la composante continue du courant de court-circuit (n° 229) et n est le facteur d'effet thermique de la composante alternative du courant de courtcircuit (n° 232). où I th = Ik" m + n Valeur efficace du courant ayant le même effet thermique et la même durée que le véritable court-circuit, qui peut comporter une composante continue et peut diminuer avec le temps: Observations A A A A A W W W ampère ampère ampère ampère watt watt watt Symbole ampère Nom Observations En pratique, le plus souvent en kW ou en MW. Unités Unité cohérente avec le SI LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 130 129 N° Grandeurs 60027-7 © CEI:2010 – 39 – 141 131-11-44 6-61 80000-6, puissance réactive Q Q ~ , Q′ puissance non active 140 Symbole de réserve ϕrM le déphasage et W watt Q = 3UI sin ϕ = S sin ϕ ϕi (CEI 80000-6, 6-48). la phase à l'origine ϕu de la tension et du courant entre la phase à l'origine où S est la puissance apparente (n° 142) et ϕ = ϕu − ϕi est le déphasage ou différence VA VA W watt volt W Symbole watt Nom La grandeur ne doit être utilisée que pour les volt réseaux alternatifs triphasés à tensions et ampère courants symétriques: (n° 134) ηrM Observations en pratique, le plus souvent en var, kvar, Mvar Unités Unité cohérente avec le SI Q~ = S 2 − P 2 , où S est la puissance ampère apparente (n° 142) et P la puissance active le rendement du moteur. courant assigné, PrM = 3U rM IrM cos ϕrMηrM où U rM est la tension assignée, I rM le Pour un moteur asynchrone triphasé: l'impédance d'onde directe de la ligne (n° 186). Z W = Z W1 est U n est la valeur nominale de la tension composée (n° 159) et où Pnat = U n2 / Z W Charge sur impédance d’onde d’une ligne alternative triphasée dans le cas de U n Pour les transformateurs à trois enroulements, il faut trois mesures ou calculs (voir la CEI 60909-0 et la CEI 60909-2). Pour un transformateur triphasé à deux enroulements (T), l'un des côtés est courtcircuité (k) et l'autre est alimenté au courant assigné (r) de ce côté à la prise principale. Observations LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 131-11-43 PrM puissance mécanique assignée d’un moteur Pnat PkrT Symbole principal 139 pertes en charge dans les enroulements d’un transformateur à courant assigné Nom de la grandeur charge d’une ligne sur impédance d’onde 421-06-03 MOD Numéro VEI et/ou CEI 138 137 N° Grandeurs – 40 – 60027-7 © CEI:2010 195-05-11 148 tension d’excitation potentiel de terre 150 151 tension continue tension de contact effective 149 60909-3 121-11-27 147 tension électrique, tension matrice de transformation 62428 146 puissance de court-circuit d'une artère de réseau alternatif triphasé au point de connexion Q puissance apparente assignée 60909-0 puissance de court-circuit puissance apparente Nom de la grandeur 145 144 601-01-14 MOD 143 60909-0 131-11-41 142 Numéro VEI et/ou CEI UF UE Ud UB U T Sr " SkQ Sk" S Symbole principal Uf UDC Symbole de réserve Ik'' le courant de court-circuit '' IkQ le courant de court-circuit et Tension sur l’enroulement d’excitation d’une machine. Pour la qualificatif DC, voir la CEI 60050-151, 151-15-02. Valeur moyenne, par exemple dans le cas d'une ligne en courant continu. U est le symbole général, sans autre indication: tension composée, tension entre phases. composantes symétriques non normalisées (voir n° 256). TS : matrice de transformation pour les Exemples pour un appareil électrique: S rG , S rT (pour les indices, voir 6.3). subtransitoire au point de connexion Q. U nQ est la tension composée nominale où " " S kQ = 3U nQ I kQ subtransitoire (n° 114). (n° 159) et Sk" = 3U n Ik" où U n est la tension composée nominale La puissance apparente de court-circuit dans un réseau alternatif triphasé symétrique est: où S = 3UI U est la tension (n° 147) composée et I est le courant (n° 104) de ligne. Dans un réseau alternatif triphasé symétrique: Observations VA VA VA VA 1 V V V V V volt ampère volt ampère volt ampère one volt volt volt volt volt Symbole volt ampère Nom Observations en pratique, le plus souvent en kVA, MVA en pratique, le plus souvent en MVA en pratique, le plus souvent en MVA en pratique, le plus souvent en kVA, MVA Unités Unité cohérente avec le SI LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. N° Grandeurs 60027-7 © CEI:2010 – 41 – 195-05-01 154 442-01-04 159 411-49-02 442-01-03 MOD 411-54-08 421-04-01 195-05-12 131-12-22 160 161 162 163 164 165 601-01-21 601-01-32 601-01-24 601-01-23 60038 421-09-01 141-03-09 195-05-02 158 157 156 155 195-05-03 153 141-03-06 411-54-06 152 Numéro VEI et/ou CEI tension de source tension de pas tension assignée d’un enroulement tension de champ assignée tension assignée tension générée synchrone tension nominale d’un réseau ou d'une ligne tension entre le point neutre ou le conducteur neutre et la terre tensions la plus élevée et la plus basse d’un réseau tension la plus élevée pour le matériel tension simple, tension phase-neutre tension composée, tension entre phases tension phase-terre tension plafond du système d'excitation Nom de la grandeur V V V V V V V V V V V V volt volt volt volt Us US U rW ,U rw U rF Ur UP Un U NE U min Uq U Step U rf Up UNmin volt La tension nominale d’un réseau est toujours volt une tension composée. volt volt volt volt volt volt Voir aussi n° 128. Voir paragraphe 6.6. Tension composée d’un appareil électrique, d’un alternateur, d’un moteur, d’un transformateur, d’une inductance, etc., avec, si nécessaire, un indice selon 6.3. Tension qui serait induite dans les enroulements d’induit en circuit ouvert, en l’absence de saturation, par le flux correspondant au courant d’excitation dans le régime considéré. VEI: tension de déplacement du point neutre VEI: tension la plus élevée (basse) d’un réseau U max i =1,2,3 dans les réseaux alternatifs triphasés avec neutre (réseaux à basse tension). i , k = 1, 2, 3 avec i ≠ k dans les réseaux alternatifs triphasés. V Symbole volt Nom V i = 1, 2, 3 dans les réseaux alternatifs triphasés. Unités Unité cohérente avec le SI volt Observations Valeur efficace la plus élevée de la tension entre phases admissible par l’appareil en permanence. UNmax UL ik UL i E U f max Symbole de réserve Um UL i N UL i L k UL i UF max Symbole principal LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. N° Grandeurs Observations – 42 – 60027-7 © CEI:2010 411-49-11 411-49-12 411-50-07 411-50-08 411-50-09 411-50-10 411-50-11 168 169 170 171 172 173 174 matrice d'admittance 179 admittance homopolaire linéique admittance directe linéique 181 Ω Ω Ω Ω Ω Ω Ω Ω S S/m S/m ohm ohm ohm ohm ohm ohm ohm ohm siemens siemens par mètre siemens par mètre Y1' Y0' Y Xσ Xs Xm X q" X "d X q' X d' Xq A Ω ohm Xd Xl V volt Y 1' = G1' + jω C1' Y 0' = G0' + jω C0' Les noms et symboles des éléments sont donnés dans la CEI 60027-2. machine synchrone à l'instant d'un courtcircuit triphasé . Pour calculer les courants de court-circuit, on doit utiliser la valeur " saturée de X d . V volt U d" X "d est la réactance équivalente d'une V Symbole volt Nom U q' U q" Unités Unité cohérente avec le SI V Observations volt Symbole de réserve U d' Symbole principal LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 180 60027-2 réactance de fuite 178 131-14-25 réactance propre 177 réactance subtransitoire transversale réactance mutuelle 411-50-12 réactance subtransitoire longitudinale réactance transitoire transversale réactance transitoire longitudinale réactance synchrone transversale réactance synchrone longitudinale tension subtransitoire transversale tension subtransitoire longitudinale tension transitoire transversale tension transitoire longitudinale Nom de la grandeur 176 175 411-49-14 167 60909-0 411-49-13 Numéro VEI et/ou CEI 166 N° Grandeurs Observations 60027-7 © CEI:2010 – 43 – 60909-0 184 impédance d’onde directe d’une ligne 603-02-23 448-11-29 MOD 448-11-27 MOD 448-11-28 MOD 186 187 188 189 ' δ ik angle de charge angle entre U i et U k profondeur de pénétration de la terre 60909-3 60909-3 192 193 194 195 ρE δE δP argument de l’impédance 191 ϑik Z = R+ jX U 1G et ω est la pulsation, μ0 la constante magnétique (CEI 60050-121, 121-11-14) et ρE la résistivité de la terre (n° 195). où δ E = 1,8514 / ωμ 0 / ρ E La profondeur de pénétration dans la terre pour une ligne de longueur infinie est: δ ik = ϕ ui − ϕ uk U P pour une machine synchrone. L’angle de charge est l’angle entre = arctan ( X/T ) pour γ argument de l’admittance γ Z '2 = R2' + jω L'2 Z 1' = R1' + jω L1' Z 0' = R0' + jω L'0 ' ' Z W1 = Z 1 / Y 1 ' Z W0 = Z 0 / Y 0 " Z G = RG + j X d" Les noms et symboles des éléments sont donnés dans la CEI 60027-2. S/m Ω Ω Ω Ω Ω/m Ω/m Ω/m rad rad rad rad m Ωm ohm ohm ohm ohm ohm par mètre ohm par mètre ohm par mètre radian radian radian radian mètre ohm mètre Symbole siemens par mètre Nom Observations le plus souvent en Ω/km le plus souvent en Ω/km le plus souvent en Ω/km Unités Unité cohérente avec le SI LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. résistivité de la terre ' Y 2 = G2' + j ω C2' Observations α = arctan (B/G ) pour Y = G + j B ϑ ZW Symbole de réserve α Z 2' Z1' Z 0' Z W1 ZW0 Z G" Z Y2' Symbole principal 190 impédance d’onde inverse linéique d’une ligne impédance d’onde directe linéique d’une ligne impédance d’onde homopolaire linéique d’une ligne impédance d’onde homopolaire d’une ligne 185 impédance subtransitoire d’un alternateur matrice d’impédance 131-14-24 183 Nom de la grandeur admittance inverse linéique Numéro VEI et/ou CEI 182 N° Grandeurs – 44 – 60027-7 © CEI:2010 longueur d’une ligne section droite rayon rayon équivalent d’un faisceau de conducteurs 60909-0 466-10-22 203 204 205 206 207 466-10-24 466-10-23 hauteur effective d’un conducteur de ligne d’une ligne aérienne audessus du sol 202 fe rT rB r q l h H f dLE min d DL Symbole principal rL A L he a dL Symbole de réserve qL où a est la distance entre deux sousconducteurs. = a/ 2 ; = a/ 3 ; = a/2; faisceau quadruple: rT faisceau triple: rT faisceau double: rT Pour rL voir n° 205, pour rT voir n° 207. sous-conducteurs rB = n n ⋅ rL ⋅ rTn −1 , où n est le nombre de Rayon d’un conducteur de ligne. Section droite d’un conducteur de ligne ligne aérienne ou câble. h = hmax − (2 / 3) fmax H = Tm / 2 f e = ω e / 2 π ,, voir n° 219 horizontale entre deux pylônes (flèche médiane), voir VEI 466-03-09 et sa Figure 446-1. f max : valeur maximale pour une portée dLi Lk Distance entre deux conducteurs de ligne: Diamètre apparent d’un conducteur divisé, voir VEI 581-03-51. Observations Unités mètre mètre mètre mètre carré mètre m m m le plus souvent en mm 2 m2 Observations le plus souvent en km Symbole m m s seconde mètre Hz m m m m hertz mètre mètre mètre mètre Nom Unité cohérente avec le SI LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. rayon des sous-conducteurs dans un faisceau constante d’inertie 201 fréquence propre 200 702-01-07 flèche d’un conducteur de ligne d’une ligne aérienne 199 distance à la masse 198 466-05-13 distance Nom de la grandeur 197 Numéro VEI et/ou CEI diamètre d’un conducteur de ligne N° Grandeurs Symboles littéraux pour l'espace et le temps 196 4 60027-7 © CEI:2010 – 45 – 411-48-28 411-48-27 411-48-30 411-48-29 411-48-26 60909-0 210 211 212 213 214 215 60909-0 218 219 constante de temps subtransitoire transversale en court-circuit 411-48-35 217 fréquence propre angulaire retard minimal constante de temps électromécanique ωe tmin Tq" Tm Tk Ta " Td0 Td" ' Td0 Td' TA sik Symbole principal Tk min T DC Symbole de réserve s s s s s s s s s s –1 seconde seconde seconde seconde seconde seconde seconde seconde seconde seconde à la puissance moins un C’est la plus courte durée entre le début d’un court-circuit et la séparation des contacts du premier pôle à s'ouvrir dans l’appareil de coupure. ωe = 2π fe avec f e selon n° 200. S’applique à une machine synchrone. où H est la constante d'inertie (voir n° 201) Tm = 2 H S’applique à une machine synchrone. S’applique à une machine synchrone. S’applique à une machine synchrone. S’applique à une machine synchrone. S’applique à une machine synchrone. s Symbole seconde Nom m Durée qui serait nécessaire pour amener les parties tournantes d’une machine du repos à la vitesse assignée si le couple d’accélération était constant et égal au quotient de la puissance active assignée par la vitesse angulaire assignée. Unités Unité cohérente avec le SI mètre Observations LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 216 durée de court-circuit constante de temps apériodique constante de temps subtransitoire longitudinale à circuit ouvert constante de temps subtransitoire longitudinale en court-circuit constante de temps transitoire longitudinale à circuit ouvert constante de temps transitoire longitudinale en court-circuit durée d'accélération espérée 411-48-15 MOD 209 Nom de la grandeur distance entre les centres de gravité des surfaces i et k Numéro VEI et/ou CEI 208 N° Grandeurs Observations – 46 – 60027-7 © CEI:2010 nombre de noeuds nombre de conducteurs par faisceau 231 facteur d’effet thermique de la composante continue du courant de court-circuit 229 230 nombre de mailles 228 60909-0 nombre de lignes 227 facteur de correction de l’impédance 225 facteur de surtension facteur d’augmentation de la résistance par effet pelliculaire 224 n N m M L k K FS FP d c b Symbole principal Symbole de réserve S’applique aux lignes aériennes à haute tension dans les réseaux alternatifs triphasés. S’applique aux réseaux alternatifs triphasés. Voir n° 129. S’applique aux réseaux alternatifs triphasés. S’applique aux réseaux alternatifs triphasés. ( U m est utilisé parfois au lieu de U b ). U b : exposant b, voir le numéro 335 u o : indice o, voir le numéro 277; k = uo /( 2U b / 3 ) ; Pour des impédances de matériel électrique dans le calcul des courants de court-circuit avec la source de tension équivalente à l’endroit du court-circuit selon la CEI 60909-0. R ~ = FS FP R = R ~ = FS FP R = Facteur pour la tension équivalente à l’endroit du court-circuit. Pour des ondes progressives sur des lignes; différent pour la tension et le courant. Observations Unités un un un un un un un un un un un un Nom 1 1 1 1 1 1 1 1 1 1 1 1 Symbole Unité cohérente avec le SI LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 226 facteur d’augmentation de la résistance par effet de proximité 223 60909-0 facteur d’amortissement 222 facteur de tension 60909-0 Nom de la grandeur 221 Numéro VEI et/ou CEI facteur de réfraction N° Grandeurs Symboles littéraux pour les valeurs numériques et les rapports de grandeurs 220 5 Observations 60027-7 © CEI:2010 – 47 – 442-01-03 MOD 436-01-15 MOD trT rapport de transformation assigné (d'un transformateur) 241 421-04-02 t rapport de transformation (d'un transformateur) 240 Symbole de réserve U rT / 3 et IrT . U rT / 3 et IrT . U rT / 3 et IrT . Le rapport de transformation assigné peut différer du rapport des nombres de spires (n° 246). assignée du côté basse tension du transformateur. U rTLV est la tension U rTHV est la tension assignée du côté haute tension et où trT = U rTHV / U rTLV ≥ 1 Voir n° 241. Voir aussi n° 242. étant C’est la valeur réduite dans le cas d’un transformateur triphasé à deux enroulements, les valeurs de référence Voir aussi n° 244. étant C’est la valeur réduite dans le cas d’un transformateur triphasé à deux enroulements, les valeurs de référence Voir aussi n° 243. étant C’est la valeur réduite dans le cas d’un transformateur alternatif triphasé à deux enroulements, les valeurs de référence S’applique en présence de perturbations. S’applique aux ondes progressives sur des lignes. S’applique aux ondes progressives sur des lignes. S’applique aux machines alternatives triphasées synchrones et asynchrones. Voir n° 129. Observations Unités un un un un un un un un un un Nom 1 1 1 1 1 1 1 1 1 1 Symbole Unité cohérente avec le SI LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. zT xT rT r impédance de court-circuit réduite d’un transformateur facteur de réduction rU 239 60909-3 236 facteur de réflexion complexe en tension rI réactance de court-circuit réduite d’un transformateur 131-15-33 235 facteur de réflexion complexe du courant p 238 131-15-32 234 nombre de paires de pôles n Symbole principal résistance de court-circuit réduite d’un transformateur 60027-1 233 facteur d’effet thermique de la composante alternative du courant de court-circuit Nom de la grandeur 237 60909-0 Numéro VEI et/ou CEI 232 N° Grandeurs Observations – 48 – 60027-7 © CEI:2010 60909-0 60909-0 248 249 604-03-06 facteur pour le calcul du courant de court-circuit permanent facteur pour le calcul de la valeur de crête du courant de court-circuit facteur de court-circuit à la terre 247 λ κ δ w v uX uR uk Symbole principal n Symbole de réserve zT . xT . uX est uR est uk est 2I k′′ Ik'' est le courant de IrG est le courant assigné et IkG le courant de court-circuit permanent d'une génératrice. où I λ = kG , λmax et λmin IrG Pour une machine synchrone: court-circuit subtransitoire (n° 114). crête (n° 118) et où ip est le courant de court-circuit de κ = Dans le cas d’un court-circuit alternatif triphasé: ip w = WHV / WLV S’applique à un réseau à neutre compensé (par bobine d'extinction) (voir VEI 195-04-09). égale à celle de valeur assignée: u Rr Voir aussi n°238; la valeur de égale à celle de rT . valeur assignée: u Rr Voir aussi n° 237; la valeur de égale à celle de Voir aussi n° 239. La valeur de U rT / 3 et IrT . 421-07-01) avec les valeurs de référence Dans le cas d’ un transformateur à deux enroulements, valeur assignée ukr (VEI Observations Unités un un un un un un un un Nom En pratique s’exprime en %. En pratique s’exprime en %. 1 1 1 1 1 1 1 En pratique s’exprime en %. Observations 1 Symbole Unité cohérente avec le SI LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 195-05-14 rapport des nombres de spires composante réactive de la tension de court-circuit réduite d’un transformateur 246 60909-0 244 composante résistive de la tension de court-circuit réduite d’un transformateur coefficient de désaccord 60909-0 243 tension de court-circuit réduite d’un transformateur Nom de la grandeur 245 60909-0 Numéro VEI et/ou CEI 242 N° Grandeurs 60027-7 © CEI:2010 – 49 – 250 60909-0 Numéro VEI et/ou CEI facteur pour le calcul du courant de court-circuit symétrique coupé Nom de la grandeur μ Symbole principal Symbole de réserve Ik" Ib Ib est le courant coupé (n° Ik'' le courant de court-circuit , où subtransitoire (n° 114). 105) et μ= Observations Unités un Nom 1 Symbole Unité cohérente avec le SI LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. N° Grandeurs Observations – 50 – 60027-7 © CEI:2010 60027-7 © CEI:2010 6 – 51 – Indices et exposants 6.1 N° Indices pour les grandeurs naturelles et les composantes dans les systèmes alternatifs triphasés Symbole principal Signification Symbole de réserve Exemple d’utilisation conducteurs de ligne L1, L2, L3 UL1, U L2 , UL3 252 enroulements W1, W2, W3 I W1, I W 2 , I W3 253 enroulements 1W1, 1W2, 1W3 I1w1 I1w2 2W1, 2W2, 2W3 I1w3 3W1, 3W2, 3W3 254 conducteur neutre N 255 source s 256 système direct Enroulements d'appareils électriques, par exemple ceux d’un transformateur connecté en delta, voir n° 253. N Côté HT 1, 2 ou 3 au début du symbole indique le côté haute, moyenne ou basse tension d’un transformateur. 1, 2 ou 3 à la fin du symbole indique l'un des trois enroulements de chaque côté d’un transformateur alternatif triphasé. IN S’applique aux réseaux à basse tension. q U s , us Voir n° 165. 1 (1) U 1, U (1) Composantes symétriques (CEI 62428): système inverse 2 (2) U 2 , U (2) système homopolaire (0) U 0 , U (0) ⎡U ⎤ ⎡ 1 ⎢ L1 ⎥ ⎢ 2 ⎢U L2 ⎥ = ⎢a ⎢U ⎥ ⎢ a ⎣ L3 ⎦ ⎣ 0 avec a = 1 a a2 e j2π/3 = − 1⎤ ⎡U 1 ⎤ ⎥ ⎢ ⎥ 1⎥ ⋅ ⎢U 2 ⎥ 1⎥⎦ ⎢⎣U 0 ⎥⎦ 1 1 +j 3 2 2 (1), (2), (0) sont utilisés dans la CEI 60909-0. 257 axe longitudinal d 258 axe transversal q 259 composante de Clarke α 260 composante de Clarke β 261 phaseur spatial s u s = uα + juβ Phaseur spatial dans un référentiel fixe. 262 phaseur spatial r ur = ud + juq Phaseur spatial dans un référentiel tournant. 263 composante active P 264 composante non active Q composantes dq0 composantes αβ 0 LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 251 Observations – 52 – 6.2 N° 60027-7 © CEI:2010 Indices pour les conditions de fonctionnement Symbole principal Signification Symbole de réserve Exemple d’utilisation Observations général a ... z Utiliser des lettres minuscules pour les modes de fonctionnement. 266 actionné a Ia S’applique à un dispositif de protection 267 coupé b Ib Courant coupé d'un disjoncteur. Voir n° 105. 268 défaut à la terre e I Ce Dans les réseaux à neutre isolé ou les réseaux compensés par bobine d’extinction. Voir n° 107 et aussi n° 125. 269 induit in U in Tension induite. 270 court-circuit triphasé k '' Ik, Ik'' , Ik3 Dans le cas d’un court-circuit triphasé, l’indice additionnel 3 n’est pas nécessaire (CEI 60909-0). Voir les numéros 112 à 114. 271 court-circuit phase-terre k1 '' Ik1 CEI 60909 272 court-circuit entre phases k2 '' Ik2 CEI 60909-0 273 court-circuit entre phases avec connexion à la terre k2E '' '' Ik2EL2 , Ik2EL3 274 maximal max 275 minimal min 276 nominal n nom 277 surtension o ov 278 de crête p 279 assigné r 280 saturé sat X d sat 281 thermique th I th Voir n° 129. 282 à vide 0 I 0M Courant à vide d'un moteur. k3 m U max, U m VEI 195-04-12 ′′ : courant circulant à travers la IkE2E terre dans le cas d’un court-circuit entre phases avec connexion à la terre (CEI 60909-0). U m : tension maximale admissible en régime permanent. 6.3 N° uo Valeur instantanée d’une surtension. ip Voir les numéros 118, 120. rat Indices pour les appareils électriques Symbole principal Signification 283 général A ... Z 284 moteur asynchrone ASM 285 faisceau de conducteurs B Symbole de réserve Exemple d’utilisation U rT2HV IM Observations Utiliser des lettres majuscules pour les matériels électriques ou leurs parties. IM: moteur à induction. VEI 466-10-22, VEI 466-10-23, VEI 466-10-24. LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 265 60027-7 © CEI:2010 N° – 53 – Symbole principal Signification Symbole de réserve Exemple d’utilisation Observations 286 transformateur de courant CT I CT 287 générateur, génératrice G U rG 288 génératrice de courant continu G– 289 alternateur G~ 290 alternateur triphasé G3 ~ 291 ligne à isolation gazeuse GIL 292 poste de sectionnement à isolation gazeuse GIS 293 liaison à haute tension continue HVDC 294 onduleur IN 295 ligne aérienne, câble L 296 conducteurs de ligne L1, L2, L3 IL1, IL2 , IL3 297 moteur M IrM 298 moteur à courant continu M– DCM 399 moteur à courant alternatif M~ ACM 300 moteur triphasé M3 ~ 301 machine MA 302 réseau N 303 conducteur neutre N Dans les réseaux à basse tension. 304 conducteur de protection PE Dans les réseaux à basse tension, VEI 195-02-09. 305 conducteur PEN PEN 306 centrale électrique PS 307 câble de garde Q 308 (bobine d') inductance R 309 rotor R 310 redresseur RF VEI 151-13-45 311 stator S Stator d’une machine électrique ou d’une turbine. VEI 811-14-01. VEI 151-13-35 G 3 U V W VEI 601-03-06 VEI 601-04-01 VEI 151-13-46 X L′ r MA réactance linéique directe: ' X L' = X 1L VEI 151-13-39, machine électrique. Dans les réseaux à basse tension, VEI 195-02-12. S SPS , SS Puissance apparente du côté haute tension du transformateur de tranche d’une centrale électrique. VEI 603-01-01. dQ1L1 S’il y a plus d’un câble de garde, utiliser: Q1, Q2, ... Qn Re LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. PHVDC – 54 – N° Symbole principal Signification protection (électrique) par écran S 313 générateur synchrone SG 314 moteur synchrone SM 315 machine synchrone SMA 316 déphaseur synchrone SPH 317 transformateur T 318 transformateur de tranche, transformateur de groupe UT 319 transformateur de tension VT 320 enroulement W 6.4 N° Exemple d’utilisation Si et Sh I S1, IS2 , I S3 Observations Exemple: courants dans le cas de trois câbles unipolaires. VEI 151-13-47. SrT BT Voir les numéros 130, 132, 163, 252, 253. U r UTLV U rVT Indices pour les emplacements, les points de références et la localisation des défauts Symbole principal Signification Symbole de réserve Exemple d’utilisation 321 emplacement des centrales A ... Z centrale A 322 terre E 323 localisation d'un F défaut, localisation d’un court-circuit 324 côté haute tension HV HT U rTHV 325 côté basse tension LV BT U rTLV 326 côté moyenne tension MV MT U rTMV 327 point neutre N 328 point de connexion, pôle P K 329 point de connexion d’un réseau Q Q1, Q2, Qn 330 terre de référence RE BE 331 points de connexion d’appareils alternatifs triphasés U, V, W u, v, w G UN x, y, z Emplacement des centrales ou de leurs parties. G: ground (usage US) " IkF1 or Observations Dans le cas de plusieurs défauts: F1, F2, F3, ... Fn. VEI 601-02-22: point neutre dans un réseau polyphasé. VEI 601-03-11: pôle d’un appareil. '' SkQ Exemple: puissance de court-circuit au point de connexion Q d’un réseau. Générateurs, moteurs, transformateurs, inductances, etc. dans des réseaux alternatifs triphasés, si nécessaire avec accessoires. LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. 312 Symbole de réserve 60027-7 © CEI:2010 60027-7 © CEI:2010 N° – 55 – Symbole principal Signification 332 nœud commun Y 333 référence au neutre dans un système direct, inverse, homopolaire 01 6.5 Exemple d’utilisation Dans le cas de composantes symétriques selon n° 256. 02 00 Exposants Symbole principal Signification Symbole de réserve Exemple d’utilisation après a n 335 avant b v 336 linéique ′ X L' 337 transitoire ′ X d' , Td' 338 subtransitoire ′′ X d'' , Td'' 339 semi-relatif * avant le symbole ∗ N° Point commun à des éléments à deux bornes (enroulements) connectés en étoile. UY 334 6.6 Observations Courant dans un générateur avant un court-circuit. I Gb XT = Observations ukr SrT Les grandeurs semi-relatives sont utilisées comme des grandeurs réduites dans les calculs de réseaux. Indices multiples et leur succession Position Signification Article Exemple (observations) 340 1 grandeur naturelle ou composante modale 6.2 U1 (système direct) 341 2 condition de fonctionnement 6.2 U1k1 (lors d’un court-circuit phase-terre) 342 3 appareil électrique 6.3 U1k1T4 (sur le quatrième transformateur) 343 4 localisation 6.4 U1k1T4HV (du côté haute tension) 344 5 indication additionnelle — U1k1T4HV max (valeur la plus élevée) U1k1T4HV max : Valeur la plus élevée de la tension directe, lors d’un court-circuit phase-terre, du côté haute tension sur le quatrième transformateur. Si nécessaire, insérer un petit espace entre les différents indices. LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. N° Symbole de réserve – 56 – 60027-7 © CEI:2010 Bibliographie CEI 60050 (toutes les parties), Vocabulaire Electrotechnique International _____________ LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. ELECTROTECHNICAL COMMISSION 3, rue de Varembé PO Box 131 CH-1211 Geneva 20 Switzerland Tel: + 41 22 919 02 11 Fax: + 41 22 919 03 00 info@iec.ch www.iec.ch LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU. INTERNATIONAL