balestro.com.br sales@balestro.com balestro balestro.industria balestroindustria SUPERIOR QUALITY GUARANTEED Brazilian company founded in the 50s, Balestro has presented consistency in its production line throughout its trajectory, began its activities with the manufacture of transformers and surge arresters and over time gained the market’s trust and respect. With the professional and OUR HISTORY technological evolution, Balestro has become a specialist in the design, development and manufacture of products for the protection of electric distribution and energy transmission networks, being today the most respected Brazilian company in the supply of surge arresters, insulators and fuse switches, polymer technology products for medium and high voltage. SCR=20kA The new generation of Balestro's Distribution Surge Arresters 3kV to 42kV The PROTEGE+ arresters offers biggest protection to the system due to its capacity to withstand short-circuit currents up to 20kA. Heavy Duty Distribution Arresters - PROTEGE+ Rated Voltage Nominal Current Standard Short Circuit Rating (0,2 s) Polution Level Accessories Wildlife Protector 3 up to 42 kV 10 kA Distribution High / Class 1 20 kA “a” up to “e” Disconnector Device, Insulating Bracket, NEMA bracket Included Post Type Insulators Dead-end and Suspension Insulators 15 to 45kV Rated Voltage Specified Cantilever Load (SCL) Upper Terminal Material Lower Terminal Thread Rated Voltage 15 up to 45kV up to 12,5kN Specified Mechanical Load (SML) 50 up to 80kN Porcelain Pollution Level (IEC 60815-2007) a up to e M16, M20, 3/4” Fuse Cutout Rated Voltage Nominal Current Basic Insulation Level (BIL) End Fittings Clevis/Tongue - Clamp top/Ball Fuse Holder 15 up to 38KV 300A 110 up to 170KV Rated Voltage Nominal Current Nominal Interrupting (asymmetrical) 15 up to 38kV 100 or 200A 5 up to 16kA RMS DISTRIBUTION Surge-Arresters (Internal Use) Rated Voltage Nominal Current Discharge class (DLT IEC 60099-4) Phase Connection 3 up to 36 kV 10kA 1 insulated cable 16 mm² x 600 mm * Others models on request High Voltage Insulators Transmission Line Arresters Classification (IEC 60099-4 / NBR 16050) SL / CLASS 2 Rated Voltage 6 up to 245kV 12 up to 336kV 10 kA 10 kA up to 40kA up to 65kA 5,5kJ/kV of Uc 8,7kJ/kV of Uc 1,4 C 1,6 C up to 1.500N.m up to 3.500N.m Short Circuit Current Repetitive charge transference (Qrs) Cantilever strength (SSL) 69 to 750kV 600 to 1000kV AC DC Speciļ¬ed mechanical load (SML) 80 to 300kN 160 to 300kN Pollution level (IEC 60815-2007) a up to e a up to e Socket, Ball, Y Clevis and Eye Socket, Ball Rated voltage System Nominal Discharge Current Energy absorption capacity SM / CLASS 3 End fittings *Disconnector device on request Station Class Surge Arresters Classification (IEC 60099-4 / NBR 16050) SL / CLASS 2 Rated Voltage 6 up to 144kV 12 up to 245kV Nominal Discharge Current Short Circuit Current TRANSMISSION Line Post Insulators Energy absorption capacity Repetitive charge transference (Qrs) Cantilever strength (SSL) SM / CLASS 3 10 kA 10 kA up to 40kA up to 65kA 5,5kJ/kV of Uc 8,7kJ/kV of Uc 1,4 C 1,6 C 34 up to 230kV Rated Voltage up to 20kN Specified Cantilever Load (SCL) Line Terminals Clamp Top or Drop tongue *Others models on request up to 2.700N.m up to 5.525N.m *Discharge counter on request Varistors Rated voltages 3kV, 4kV, 5kV and 6kV (5kA and 10kA); Standards NBR16050, IEC60099-4 and ANSI / IEEE C62.11; IEC - DM and DH (distribution); IEC - SL and SM (intermediate, station and TLA). *More information on request Surge Counter Ciclometer Minimum Count Current (wave 8/20µs) Meter Scale (non linear) Terminals for cables 6 digits 100 A 0 to 5 mA Peak / (√2) up to 400MCM * Others models on request sales@balestro.com balestro www.balestro.com.br +55 19 3814-9000 Av. Geraldo Potyguara Silveira Franco, 298 Mogi Mirim - SP - Brasil balestroindustria balestro.industria +55 19 98149-3708 Precisely Right. ISO 9001 DESDE 1997