Uploaded by Yusuf Arya Yudanto

Kelompok 2 Analisis PIK FMEA Unit SA II di PT Petrokimia Gresik

advertisement
ANALISIS PROSES INDUSTRI KIMIA / 2 SKS
Dosen Pengampu: Tjoek Oedowo, S.T., M.H.
ANALISIS PROSES PRODUKSI ASAM
SULFAT DENGAN METODE FAILURE MODE
AND EFFECT ANALYSIS (FMEA)
DEPARTEMEN PRODUKSI III B (UNIT SULPHURIC ACID II) - PT. PETROKIMIA
GRESIK
01
Disusun Oleh Kelompok 2:
Dicky Rinaldi (40040117640004)
M. Kelvin Nandita (40040117640010)
Inke Yolanda Putri W. (40040117640016)
M. Ravi Bachtiar S. (40040117640029)
Yusuf Arya Y. (40040117640031)
Mifta Nur H. (40040117640035)
Mei Syfa Nisrina (40040117640047)
Kresna Suryadi (40040117640022)
FMEA UNIT SA II PT PETROKIMIA GRESIK
Today's Discussion
What actually FMEA is?
Production Process Explanation
of H2SO4
Process Analysis by FMEA
Conclusion
02
TOPICS TO
DISCUSS
FMEA UNIT SA II PT PETROKIMIA GRESIK
FMEA
Failure Mode and Effect Analysis (FMEA) adalah
Salah satu metode yang digunakan untuk
memeriksa setiap kegagalan yang berpotens
terjadi dari proses produksi dan menentukan
efek kegagalan pada sistem.
3 Langkah dalam FMEA (Gumilar, 2012):
Mendefinisikan Proses
Melakukan Analisis
Mendokumentasikan Hasil
It's crucial to know the root
and find the solutions
03
FMEA UNIT SA II PT PETROKIMIA GRESIK
04
This figure shows a typical worksheet
used in performing a FMEA.
FMEA UNIT SA II PT PETROKIMIA GRESIK
TAHAPAN PRODUKSI H2SO4
Sulphur Handling (Seksi 1000)
SO2 Generation (Seksi 1100)
SO2 Conversion (Seksi 1200)
Drying Air & SO3 Absorption
(Seksi 1300)
H2SO4 Storage and
Distribution
Quality Control
05
FMEA UNIT SA II PT PETROKIMIA GRESIK
06
This figure shows PFD of Sulphur
Handling
TABULASI FMEA PADA SEKSI SULPHUR HANDLING
07
FMEA UNIT SA II PT PETROKIMIA GRESIK
08
This figure shows PFD of SO2
Generation and SO2 Conversion
TABULASI FMEA PADA SEKSI SO2 GENERATION
09
TABULASI FMEA PADA SEKSI SO2 CONVERSION
10
FMEA UNIT SA II PT PETROKIMIA GRESIK
This figure shows PFD of Drying
Air & SO3 Absorption
11
TABULASI FMEA PADA SEKSI DRYING AIR & SO3 ABSORPTION
12
TABULASI FMEA PADA SEKSI H2SO4 STORAGE & DISTRIBUTION
13
FMEA UNIT SA II PT PETROKIMIA GRESIK
14
This figure shows Specification of
Product (H2SO4)
TABULASI FMEA PADA QUALITY CONTROL
15
FMEA UNIT SA II PT PETROKIMIA GRESIK
FMEA Worksheet
Berdasarkan FMEA Worksheet,
setiap seksi pada proses produksi
Asam Sulfat di PT Petrokimia Gresik
memiliki potensi kegagalan sistem
yang mungkin terjadi.
Functional Failures
16
Kebijakan perawatan/rekomendasi
yang diberikan untuk menghadapi
functional failures secara
keseluruhan yaitu:
Turn Around (TA) dan Evaluasi
yang dilakukan dengan teliti dan
sistematis.
Preventive Maintenance dan
Replacement.
CONCLUSIONS
FMEA UNIT SA II PT PETROKIMIA GRESIK
TERIMA KASIH
“Carefulness costs you nothing. Carelessness may cost you your life.” –
Safety saying, early 1900’s
Stay Safe and Wash
Your Hands!
17
Download