Calculating pressure containment of welding tees

advertisement

Menu
Calculating pressure containment of welding tees
by Martin Blackman
There are at least three recognised methods for assessment of branch intersections. These are most often
applied to fabricated connections on pressure vessels and piping rather than welding tees.
Welding tees to ASME B16.9 are normally qualified by vendor burst tests, but that doesn’t help if you need to
assess a corroded or eroded fitting, or you want to check up on a purchased fitting. (One paper from
2014, PVP2014-28265, found non-compliant fittings that failed below their required burst pressures). Another
standard, EN10253, gives recommended fitting thicknesses and calculation methods.
For pressure calculation of welding tees, we’ll cover and compare three Code methods and another approach
from a recent research paper. The methods considered are as follows:
No.
Method
Reference(s)
1
Area Replacement
ASME B31.3, ASME VIII Div. 1, PVP2014-28265
No.
Method
Reference(s)
2
Pressure-Area
EN13445, EN13480, ASME VIII Div 2, EN10253
3
Local Stress
PD 5500
4
Local Stress
PVT-17-1119
The area replacement method is perhaps the one most familiar to mechanical engineers. The area of
pressure retaining wall removed must be replaced by sufficient thickness in the locally surrounding metal. It
has not typically been used for welding tees, however a way to apply the method will be developed in this
article.
The pressure-area method has its origin in Kellogg “Design of Piping Systems”. The concept is that pressure
times the area of contained fluid must be equated by allowable stress times the area of metal. It has been
adopted in European codes such as EN13445-3, EN13480-3 and more recently in ASME VIII Division 2.
Standard EN10253 for fittings includes examples of how to calculate adequacy of pressure containment.
The PD5500 method is based on research into local stresses at pressure vessel branches in the 1960’s.
The fourth method is essentially a local stress check in the tee crotch area. It is based on shell theory with an
empirical correction to bring it in line with FEA results.
For most of these approaches, you need to know the crotch radius and thickness (shown as below).
This may not be a problem for fittings purchased in accordance with EN10253, as that standard lists
suggested thicknesses and radii. For ASME B16.9 fittings, you need to measure the actual fitting to get the
information. Wall thickness can be measured using an ultrasonic probe for instance.
Area replacement method
In the B31 codes, this method is conventionally applied to fabricated intersections. It is also applied to
extruded tees, however the approach is fairly awkward, involving fitment of rectangles into curved sections
The codes don’t show a method of assessing welding tees, however the curved profile of the welding tee
does lend itself well to a simple calculation. This problem was addressed in an ASME paper from 2014, “Burst
Tests of B16.9 Welded Tees.”, PVP2014-28265, in which an equation for thickness was given.
[eqn 1a]
In the above, the first term represents A2, the second represents A4 (the crotch region), while A3 is
conservatively set to zero. The factor K is from ASME B31.3 Cl. 304.3.4(e), and goes from 1 for full size
intersections to 0.7 for small branches (Db/Dh<=0.15). This factor does not appear in the area-replacement
formulae for fabricated tees, nor in the ASME VIII Div. 1 method.
Eqn 1a provides a good start, but it was not really the main thrust of the paper. So let’s make this approach a
little more rigorous via the following modifications –
use the centreline radius of curvature to calculate length of reinforcement for A4
split A4 into two regions – ‘header side’ (the first 45 degrees of the crotch) and ‘branch side’ (the
remainder)
reduce length of A2 so that it stops at the start of the crotch region
limit reinforcement zones to B31.3 limits for extruded tees, but no further than the ends of the fitting
(minus one times thickness for tapering)
consider reinforcement in the branch, if within the limits (region A3)
Setting reinforcement limits:
where C and M are as shown below:
Limiting angle for reinforcement:
This leads to the following form of the equation for the area replacement check.
[eqn 1b]
This is based on being constant throughout crotch – alternatively, replace
in the calculation of alpha.
For design, we might assume constant thickness throughout fitting (
crotch thickness multiple of matching header nominal thickness,
and evaluate the following equation:
with
in the third term and
) and adopt a guess for the
. Use this for a first estimate of
[eqn 1c]
We would then iterate until the value of N converges.
It should be noted that none of these versions of the area replacement method are specifically endorsed by
any Code. At this stage I would also be wary of using a K-factor of less than one until proven adequate in this
application.
General Issues with the Area replacement method*
There is a lack of agreement concerning distances over which reinforcing material should be placed to
be effective
The rule is not based on quantitative assessment of peak stresses nor theoretical models
Does not provide a uniform factor of safety over the full range of header/branch geometries. There is
no consistent margin with respect to shakedown, distortion or fatigue.
In thick wall equipment it may give excessively rigid designs (with attendant problems in welding for
fabricated intersections)
* Ref. PD 6550 Part 2 Explanatory Supplement to BS5500:1988
Pressure-area method
The intersection is broken into 4 quadrants for assessment. The assessment is in accordance with equation
2:
Examining the formula, we can see that increasing diameter of the header or branch increases the pressurearea of the quadrant, necessitating a thicker wall. If we step back and consider it, it’s actually just a
generalisation of the basic hoop stress formula. The following is for a cylinder; a similar approach could be
taken to derive the equation for a sphere.
Per unit length:
or
The method differs slightly from the original Kellogg approach, which considered stress intensity by further
adding half the pressure to the stress.
Formulae
As there are quite a number of equations involved in the actual calculation, they are not reproduced here.
Instead refer to EN10253-2 Section A.5.2.
Limitations
The wall thickness
and
apply to the whole perimeter of the run and the branch,
respectively. At transitions between the run and the branch (crotch zone) the inside and outside
surfaces shall merge smoothly.
The minimum wall thickness at the branch
shall not be larger than
, the minimum wall
thickness at the run.
Issues with the Pressure – Area method
The issues with this method would appear to be similar to those of the area replacement method, namely
There is no obvious universal law governing distances over which the reinforcing calculation should be
made
It is not based on quantitative assessment of peak stresses
Does not provide a uniform factor of safety over the full range of header/branch geometries. There is
no consistent margin with respect to shakedown, distortion or fatigue.
The EN method equations are not given in detail here. Refer to EN10253-2 Annex A for a full demonstration
of the method.
PD5500
Section 3.5.4.3 of PD5500 contains a method for calculation of vessel nozzle connections by imposing a limit
on local stress, based on the work of Leckie & Penny (1963). It makes the assumption of a right-angle
intersection, ie there is no recognition of the effect of a radiused intersection.
To apply this method to welding tees, first select a value for
and calculate
as below:
The equation should be iterated until it converges. Then a further check is made on
In these formulae,
as follows:
and are the mean header and branch diameters respectively.
Issues with the PD5500 method
This method is simple and quick to apply, however it may not adequately consider the effect of fitting size –
i.e. it could assume the reinforcement zone is larger than available in a pipe fitting.
PVT-17-1119
In this paper, shell theory is used to calculate a theoretical membrane stress in the tee crotch. The calculated
stress overestimates the actual stress due to the reinforcing effect of the straight pipe and the rapidly
changing curvature in this region. However, using an empirical equation, it is then adjusted to match quite
well with stresses from finite element analysis. The equation is said to be typically 0 to 15% on the
conservative side for the range of geometries considered.
Formulae
Although not overly complex, due to the number of equations and the need to apply numerical
differentiation the method is not reproduced here.
Issues with PVT-17-1119 method
This approach has limitations in terms of geometry and thickness parameters due to the range of fittings
considered in the research.
One interesting difference with this method is that a smaller crotch radius leads to higher local stress and an
increase in wall thickness required. The pressure-area & area replacement methods both imply the opposite
in terms of wall thickness required. Burst tests generally agree that a smaller crotch radius for an otherwise
identical welding tee has greater capacity. While stresses may start off higher, the additional surrounding
metal makes up for it as yielding progresses.
This demonstrates the shortcomings of elastic analysis methods when used for pressure containment of
complex components. However, the local stress approach may be relevant when issues such as fatigue or
stress corrosion cracking are of concern.
Brief Comparison of Methods
Required thicknesses were calculated by each method for four geometry variations (assuming constant
thickness throughout each welding tee). The value of K was set to 1 for the area replacement calculations.
The notable outcome of comparison is the remarkable agreement between the pressure-area and area
replacement approaches. However we have just considered a small sample of fittings, so we won’t make any
firm conclusions here.
The PD5500 method consistently generated the thinnest or near-thinnest wall. This tends to confirm the
possibility that some tee fittings have less reinforcement length than assumed for this equation (which is
intended for vessels).
PVT-17-1119 results varied from less to more conservative, though it mostly leaned to the conservative side.
For these calculations, local stresses were limited to
(the ASME B31.3 allowable stress for A106 Gr. B).
Under ASME VIII Div. 2, local stresses may now be permitted to reach the yield stress for certain materials
and operating conditions, however for this comparison that would provide an ‘unfair advantage’ as the
pressure used for calculation is based on hoop stress of in the nominal wall.
Conclusion
At this point in time, the pressure-area method as given in EN10253-2 is the only fully codified approach for
welding tees. The area replacement method demonstrated here seems to give similar results and the
concept is familiar to most engineers, however its use with welding tees is not spelled out in codes. The
method in PD5500 consistently produces the thinnest wall and may not adequately consider the effect of
fitting dimensions. PVT-17-1119 tends to require thicker wall on average as it tries to keep the local
membrane stresses within code limits and it has a typical error margin in the range of 0 to +15%.
Martin Blackman
Martin helps clients keep on top of their pressure piping and equipment integrity issues via stress analysis, FEA
and fitness for service. He is the author of various articles, an ASME paper and software including the Salad postprocessor for CAESAR II and web apps on this site. In a former life he played whizzbang lead guitar, but now he
just plays old albums..
www.xtrados.com
Share this:



Related
‘Quick and Dirty’ FFS of Fittings
December 8, 2016
In "Articles"
Replacement of an existing piping
system
May 10, 2017
In "Articles"
G’day, I’m a hoop stress engineer!
March 10, 2017
In "Blog"
B31.3 branch stress own-goal
 Piping fatigue and corrosion

1 thought on “Calculating pressure containment of welding tees”
Michail Golubjev
April 9, 2019 at 7:04 pm
Great article!
Reply
Leave a Reply
Enter your comment here...
This site uses Akismet to reduce spam. Learn how your comment data is processed.
Search …
Select Language
Powered by
Translate
Sign up
to see all new articles
Email
Unsubscribe anytime
Subscribe
Categories
Articles
Blog
CAESAR II
Corrosion
Design
Education
Fatigue
FEA
Fitness for service
Inspection
Interviews
Materials
Pipe stress
Pipe supports
Pressure containment
Profession
Software
Tutorials
Vessels
RSS - Posts
RSS - Comments
Categories
Select Category
Recent Posts
CSiPlant – inserting a flexible nozzle
Nozzle Pro – Unreinforced Tee
Easy vacuum checks for piping
Improving LNG Plant Piping
FFS Interpolator
Recent Comments
rohit patel on Piping fatigue and corrosion
Michail Golubjev on Calculating pressure containment of welding tees
Martin Blackman on Pipe Support Selection for Bare Pipe
Jorge on Pipe Support Selection for Bare Pipe
Martin Blackman on Pipe Support Selection for Bare Pipe
© 2022 Xtrados Pty Ltd
Download