kÉï=~ë=çÑW= NMKOMMU `OH fåëí~ää~íáçå=fåëíêìÅíáçåë båÖäáëÜ General information Sirona Dental Systems GmbH General information About this document This document describes how to perform the installation of the C2+ dental treatment center. The installation of optional equipment is described in detail in other documents. kÉï=~ë=çÑW= For installing optional equipment, please refer to the following documents (among others): • SIROLUX FANTASTIC Installation Instructions, Order Number 51 55 556 • SIVISION 3 Installation Instructions, Order Number 59 58 421 • SIVISION 3 Kompakt Installation Instructions, Order Number 59 58 389 NMKOMMU Modification compared with last edition: 02.2006 Chapter or paragraph, page 24 Final Assembly of the Narrow Backrest ................. 33 25 Final Assembly of the Wide Backrest .................... 34 2 59 58 470 D 3370 D 3370.031.01.10.02 Sirona Dental Systems GmbH Table of contents 1 Safety ..................................................................................................5 2 Checks and Prerequirements ..............................................................6 3 Checking the Supply Lines ..................................................................7 4 Installing the Narrow Backrest .............................................................8 5 Installing the Wide Backrest ................................................................9 6 Installation with Motor-Driven Headrest.............................................10 7 Connection of Motor-driven Headrest................................................11 8 Preparing the Chair for Installation ....................................................12 9 Fastening the Chair Base to the Floor ...............................................13 ÇÉìíëÅÜ Table of contents 10 Connecting Air and Water .................................................................15 11 Operating the water unit without disinfection system.........................16 12 Electrical Connection .........................................................................17 13 Fastening of the Chair to the Floor ....................................................18 14 Adapting the Dentist Element ............................................................19 16 Adapting the Water Unit ....................................................................21 17 Water Unit: Making Connections.......................................................23 18 Adapting the Assistant Element.........................................................24 Ñê~å´~áë 15 Preparing Chair and Water Unit ........................................................20 19 Assistant Element: Making Hose Connections ..................................25 20 Valve set additional units: Making the hose connections ..................26 21 Distributor and Fuse Box ...................................................................27 22 Attaching the Water Unit Housing Covers .........................................28 24 Final Assembly of the Narrow Backrest.............................................33 25 Final Assembly of the Wide Backrest ................................................34 26 Installing the Seat Padding ................................................................35 27 Starting up the Treatment Unit ..........................................................36 28 Compare and adjust operating air pressures.....................................37 59 58 470 D 3370 D 3370.031.01.10.02 3 Éëé~¥çä 23 Concluding Work ...............................................................................31 Table of contents Sirona Dental Systems GmbH 29 Checking the Safety Switches ...........................................................39 30 For the Customer … ..........................................................................40 31 Fastening the Chair to the Floor with the M1 Adapter Plate..............42 32 Settings on Dentist and Assistant Elements......................................43 33 Changing Function on "C" Foot Switch .............................................46 34 Demonstration Unit without Water Connection..................................47 35 Packing Position ................................................................................48 36 Reversing the Direction of the Travel Track ......................................49 4 59 58 470 D 3370 D 3370.031.01.10.02 Sirona Dental Systems GmbH 1 1 Safety Safety ATTENTION It is essential that you comply with the warning and safety information contained in the Installationsanleitung. All such information is highlighted by the captions NOTE, ATTENTION, and CAUTION. ATTENTION The installation must be carried out in accordance with the requirements stated in our Installationsanleitung. ATTENTION Use an ESD wrist band. Connect it to the protective ground wire. ATTENTION When opening the unit: Please observe the safety measures for handling PC boards (ESD). Touch a ground point to discharge static electricity before handling any components. ATTENTION båÖäáëÜ Installation may be carried out only by personnel expressly authorized by Sirona. ATTENTION It is essential that you switch off the treatment center PRIOR to starting the installation. ATTENTION For reasons of product safety, only original Sirona accessories approved for this product, or accessories from third parties approved by Sirona, may be used. The user is responsible for dangers resulting from the use of non-approved accessories. If any devices not approved by Sirona are connected, they must comply with the applicable standards, e.g.: • IEC 60950 for information technology equipment and • IEC IEC 60601-1 for medical electrical equipment In case of doubt, contact the manufacturer of the system components. ATTENTION Any person who assembles or modifies a medical electrical system complying with the standard IEC 60 601-1-1 (safety requirements for medical electrical equipment) by combining it with other equipment (e.g. when connecting a PC) is responsible for ensuring that the requirements of this regulation are met to their full extent for the safety of the patients, the operators and the environment. ATTENTION To ensure the operational readiness of medical electrical equipment, the use of mobile radio telephones in the practice or hospital area is prohibited. 59 58 470 D 3370 D 3370.031.01.10.02 5 2 Checks and Prerequirements 2 Sirona Dental Systems GmbH Checks and Prerequirements Suction machine Air oil-free N >80 µm Cold water (drinking water quality) Dilution hardness Water quality Air quality Lime deposits and corrosion residues in tap water can lead to the following malfunctions: Oil-free, dry and hygienically perfect air is required for driving the highspeed handpiece, for cooling the burr drives and for the cooling spray. • Premature clogging of the filters in the unit • Rapid clogging of the fine water paths and jets in the treatment instruments For these reasons, the following points must be observed: • If the water hardness exceeds 12° dH (=2.15mmol), install a water softener. • Set dilution hardness to 8° dH (1.43mmol). • Install a conventional fine filter. Fineness: >80µm (0.08mm). • Installation must be performed in compliance with the recommendations of the national installation requirements (e.g. EN1717/DIN 1988). • The water quality must comply with the national requirements for drinking water. • The connection must be made to cold water. 6 Suction line Install condensate separate K. With a vacuum of pu >0.18 bar back pressure the treatment center must be retrofitted with the “Vacuum limiter” retrofit kit (Order No.: 59 68 826). 59 58 470 D 3370 D 3370.031.01.10.02 Sirona Dental Systems GmbH 3 3 Checking the Supply Lines Checking the Supply Lines 1. Supply through the floor 3/8“ max. 60 mm H 2. e a 0 – 5 mm d B a s e min. 500mm Installation template 3. båÖäáëÜ Solder fittings: 3/8" ext. thread Ventilation ca. 500mm ca. 250mm Supply above the floor ca. 200mm Supply through the floor Supply above the floor • Unfold the mounting template. • Cut out the installation field. Supply tube ends, corner valves and leads are routed as shown (for details see Mounting Template). • Lay the template over lead ends on the site and check the distances of the installation field from the walls in accordance with the practice. • Then check the installation for the following: 1. The top edges of the corner valves for air and water must not project more than 60 mm above the upper surface of the finished floor. 2. The suction and drain pipes must finish flush with the upper surface of the floor. (Permissible deviation: +5 mm). Internal diameter for both pipes: 36.5 mm ∅. 3. The electric leads must project by at least 500 mm. 59 58 470 D 3370 D 3370.031.01.10.02 For the connection, the retrofit kit for installation above ground 33 17 265 is required. ATTENTION Clean out the air and water pipes (metal chips!). 7 4 Installing the Narrow Backrest 4 Sirona Dental Systems GmbH Installing the Narrow Backrest 3. 1. 5. 2. i 4. P 1. Remove the six screws and four washers from the sword. 2. Pull off backrest cover. 3. Pull out the headrest to its stop position. 4. Fit the backrest onto the sword from above. 5. Fasten the backrest with the six screws removed under item 1. . i NOTE With the electrical headrest the padding flap P is fastened with the two middle screws. Never use washers. ATTENTION Tighten all screws. Screws that are not tightened can lead to functional disturbances when moving the headrest in and out. 8 59 58 470 D 3370 D 3370.031.01.10.02 Sirona Dental Systems GmbH 5 5 Installing the Wide Backrest Installing the Wide Backrest 4. i 2. P 1. 6. båÖäáëÜ 3. 5. A B 7. C ATTENTION A C i NOTE The order of installation must be complied with exactly to guarantee the parallelism of the guide rods on the slide of the headrest. With the electrical headrest the padding flap P is fastened with the two middle screws. Never use washers. 1. Remove the six screws and four washers from the strut. Remove screws A on the side of the strut. 7. 2. Pull off backrest cover. 3. Remove two screws from the backrest (for use later at position C). When screwing in screw A, make sure that the threaded spindle is not bent. Use open-end spanner SW10. 4. Pull out the head support to its stop position. 5. Place the metal bracket, tilted slightly backward, onto point B and tilt the backrest forward. 6. Retighten the backrest with the six screws removed under 1. above. 59 58 470 D 3370 D 3370.031.01.10.02 Screw in screws A (see "ATTENTION") and C. ATTENTION ATTENTION Tighten all screws. Screws that have not been tightened can result in malfunctions when the backrest is driven in and out. 9 6 Installation with Motor-Driven Headrest 6 Sirona Dental Systems GmbH Installation with Motor-Driven Headrest E D S 2. 3.D i G E F 1. 4. 1. Remove retaining ring S from driving pin F and pull the pin out. 2. Place fork D on spindle nut E. i 6. NOTE Make sure spindle nut E is properly positioned! Flat end of spindle nut facing fork D! 3. Insert fork D in the slide of headrest G. 4. Insert driving pin F from below and secure it with retaining ring S. 5. Remove cable ties. 6. Remove the (styrofoam) transport safety device. 10 5. 59 58 470 D 3370 D 3370.031.01.10.02 Sirona Dental Systems GmbH 7 7 Connection of Motor-driven Headrest Connection of Motor-driven Headrest X4 X3 X5 4. L 3. H 2. 5. I båÖäáëÜ G G 6. M V 1. / 8. 1. 1. Unscrew cover M. Undo two screws on the distributor housing and remove cover V. 2. Loosen screws G. Insert lead with connector X4 through hole H and run it behind cable clip I to the board. Plug in connector X4. 3. Pass connector X5 through hole H and plug in. 4. Run tilt-part cables with connector X3 through guide L to the board. Plug in connector X3. 5. Retighten cable clip I with screws G. 6. Screw cover V of the distributor housing back on. 7. Interconnect connectors X1 and X2 (floating connection) and place them one after the other into the recess. 7. ATTENTION Make sure all hexagon cable sleeves fit properly. 8. 59 58 470 D 3370 D 3370.031.01.10.02 Screw cover M back on guide L. 11 8 Preparing the Chair for Installation 8 Sirona Dental Systems GmbH Preparing the Chair for Installation 7. 5. 6. 2. 7. 8. 3. 4. 1. 1. Remove the front faceplate of the base. It is fitted on the lateral faceplates (if necessary, carefully prize the faceplates apart with a screwdriver). 2. Unscrew the two screws (with washers) at the front of the cover. Take off the cover. 3. Remove the transport safety device. 4. Pull off the small bellows from the foot control. Remove the rear faceplate of the base. It is fitted on the lateral faceplates (if necessary, carefully prize the faceplates apart with a screwdriver). 5. Unscrew the top faceplate (two screws with washers). 6. Loosen the bellows in the lower region. 7. Separate the chair from the pallet: Unscrew four fastening screws (with washers). 8. Remove lateral cover on each side. 12 i NOTE If the C2+ is being assembled as a replacement for an M1 that was previously located at this position, an adapter board can be ordered (Order No. 58 70 493) with which the existing mounting holes can still be used. For installation information regarding this point refer to “Fastening the Chair to the Floor with the M1 Adapter Plate” on page 42 i NOTE A chair plate can be ordered for particularly uneven floors (Order No. 58 71 913) which compensates the unevenness of the floor. For installation information regarding this point refer to “Fastening the Chair Base to the Floor” on page 13 59 58 470 D 3370 D 3370.031.01.10.02 Sirona Dental Systems GmbH 9 9 Fastening the Chair Base to the Floor Fastening the Chair Base to the Floor 2. M X 7mm M 3. Y 4. 160 mm D 80 mm min. Z B’ B 20mm Option E C 1. A 5. båÖäáëÜ Ø 12mm H G F K i ATTENTION NOTE For special requirements (e.g. demo operation at a fair), installation on a demo plate is possible. In this case please observe the installation instructions provided with the demo plate and proceed with chapter “10 Connecting Air and Water” on page 15. Floor heating! Determine the position of the heating coils with the heating turned on. 1. DO NOT use dowels for wooden floors. With wooden floors provide appropriate supporting beams and make the necessary arrangements. With wooden floors drill 7 mm ∅, depth 80 mm. 2. Drill the dowel holes. ATTENTION Position the mounting template in relation to the corner valves, set to dimensions. Center-punch the fastening points A to K . ATTENTION The fastening points C and H bear the main load of the floor fastening. ATTENTION Drilled hole depth: The screed X and sound-deadening layer Y have to be overcome and a hole at least 80 mm deep has to be drilled in the load-bearing concrete Z for a secure anchorage. 59 58 470 D 3370 D 3370.031.01.10.02 3. Insert the dowels into the concrete support. 4. Option (chair plate 58 71 913): Align the chair plate with the drill holes. 5. Grasp the chair in the M area, lift it off the pallet and move into position. ATTENTION Do not lift the chair by its backrest or by the bracket for the upholstery. 13 9 Fastening the Chair Base to the Floor Sirona Dental Systems GmbH 10x160 (5 ea.) 10x80 (5 ea.) D 58 71 848 D3370 Option 7. S 6. B’ B C A E H K S KS 6. Screw the chair to positions A, B, B’, D, E and K. – 1 mm: Order No. 47 09 304 – With a concrete floor: Use 10 x 160 wood screws and washers. – 2 mm: Order No. 47 09 312 – With a wooden floor: Use 10 x 80 wood screws and washers. i NOTE 7. Option Screw protective ground conductor S to the chair plate and the bottom of the chair (do not forget the contact plate KS). When using the chair plate, the chair is screwed with the chair plate to the floor using the same screws as above. i NOTE The chair must be fastened at positions C and H, after the electrical connection has been made. The chair can then be moved upward with the foot control (refer to page 18). ATTENTION The chair base must be exactly adjusted to the horizontal position! • 14 For compensating any unevenness in the floor, shimming plates contained in the package can be used. More shimming plates can be ordered by quoting the following order numbers: 59 58 470 D 3370 D 3370.031.01.10.02 Sirona Dental Systems GmbH 10 Connecting Air and Water 10 Connecting Air and Water Air A 1. B B båÖäáëÜ Water Air 1. right ATTENTION Do not damage the sanitary hoses and cables. ATTENTION Make sure they are connected properly! ATTENTION The sanitary hoses must not touch belt A and sheet metal cover B! ATTENTION Before connecting the sanitary hoses to the corner valves, the water and air inlet hoses must be thoroughly rinsed and blown out by opening the corner valves. 1. wrong right wrong ATTENTION Use only properly fitting open-jawed wrenches for installation. Never use pipe wrenches. Observe the permissible bending radius and avoid sharp bends. Never twist the hoses. Also make sure that unintentional twisting does not occur when tightening down. Use an additional wrench to prevent any twisting. Tensile forces must not act on the connecting hoses. Make sure that tensile stressing does not occur after installation either. Connect the flexible connecting pipes for water (green marking) and air (blue marking) to the on-site corner valves. Screw seals tight with nuts. 59 58 470 D 3370 D 3370.031.01.10.02 15 11 Operating the water unit without disinfection system Sirona Dental Systems GmbH 11 Operating the water unit without disinfection system YE 1. 2. 4. MV35 GN F MV1 A A AD3 3. B 5. 7. 6. C i E NOTE When it leaves the factors, the patient's chair has been prepared for operation of the water unit with the disinfection system. If the water unit is operate without the disinfection system, remove MV1 and replace with AD3. 1. Remove conductors GN(+) and YE(-) from MV1 and insulate. 2. Turn coil F of MV1 slightly and pull off. 3. Loosen screws D and remove MV1. 4. Insert two new O-rings and set pressure regulator AD3 into place, correctly positioned. Attach firmly with screws A. Be careful with the O-rings! i NOTE Pressure regulator AD3 is included in the water unit package. 5. Undo two screws B and remove nipple holding plate. 6. Remove plug C and attach hose E from AD3. 7. Reattach nipple holding plate with screws. 16 59 58 470 D 3370 D 3370.031.01.10.02 Sirona Dental Systems GmbH 12 Electrical Connection 12 Electrical Connection X4 47 2. X3 49 4 3 X2 2 1 4. 3. NL båÖäáëÜ 1. 5. ATTENTION ATTENTION Switch OFF power from the main switch for the electrical installation. The control voltages connected to X2, X3 and X4 may amount to max. 230V, 6A. 1. Connect power line: N, L, 5. 2. Connect control leads of suction pump to X4.47 and 49. Fasten the control cables from X2, X3 and X4 together with a cable tie. • Switch ON power from the main switch for the electrical installation. i NOTE Connecting technique for X2, X3, X4: First press with a screwdriver, and then plug in. 3. Connect call leads to X2.1 and 2. Only the push-button function is possible. 4. X3.3 and 4 are terminal points for key # (for example, composite function of the ceiling model SIROLUX FANTASTIC, when present). With the SIROLUX FANTASTIC ceiling model, two cables have to be laid from the ceiling to the installation tube in the connection area of the chair. Note setting as switch or push-button (momentary). (See Operating Instructions, chapter ”Basic Workstation Settings, Mode Key”). 59 58 470 D 3370 D 3370.031.01.10.02 17 13 Fastening of the Chair to the Floor Sirona Dental Systems GmbH 13 Fastening of the Chair to the Floor C 3. H 2. 10x200 (2 ea.) 1. 4. 58 71 848 D3370 10x110 (2 ea.) Fastening Points C and H 1. Switch on the main switch. 2. Let the chair travel upwards with the foot control. (Observe Operating Instructions!) 3. Fasten the chair to the floor with two wood screws and washers. – With a concrete floor: Use 10 x 200 wood screws. – With a wooden floor: Use 10 x 110 wood screws. – With the M1 adapter plate (refer also to page 42): Use M 10 x 40 4. 18 Switch the main switch off. 59 58 470 D 3370 D 3370.031.01.10.02 Sirona Dental Systems GmbH 14 Adapting the Dentist Element 14 Adapting the Dentist Element 5. ca. 3 kg 6,6 lbs 4. båÖäáëÜ 2. 3. 1. 6. A 1. Hinge up the flexible cover. Push the dentist element onto the guide bolts of the slide. 5. 2. Insert two screws, nuts and washers in the plugged-in connection. 3. Insert the spacer plate (2x0.5mm, 1x1mm) If the customer wishes to have the dentist element in the neutral position at the head end of the chair, it is necessary to repole as described in Chapter “Reversing the Direction of the Travel Track” on page 49 i 6. NOTE Inserting the intermediate plates enables the dentist element head to be aligned horizontally. The unit-specific tolerances can be compensated for by an empirically determined combination of the intermediate plates . To compensate for the still missing instruments the dentist element head must be loaded with approx. 3kg during the adjustment. 4. i i Put on the tray support. NOTE Plug the ball stopper A into the unoccupied instrument holder to prevent a treatment instrument from being deposited inadvertently in this holder. NOTE The setting of the height adjustment and the swivel stops of the support arms is described on page 43 and 45. Tighten the screws. Check the levelness of the dentist element head with a spirit level at different places on the track. If necessary loosen the screws again, remove the spacer plate and repeat the process until the dentist element stands level. 59 58 470 D 3370 D 3370.031.01.10.02 19 15 Preparing Chair and Water Unit Sirona Dental Systems GmbH 15 Preparing Chair and Water Unit Grease SYNTHESO PRO AA2 1. 7. 3. 2. 5. 6. A 4. K 1. Remove the transport protection tape. 2. Undo two screws of fuse box cover and remove cover. 3. Undo and remove three screws of the cable holder on the distributor box. 4. Check to see if the hoses are arranged as shown in the drawing. Remove protective bag from connector and cable ties K. 5. Check to make sure that the electrical leads have been routed through the other opening in the stand and through the cable holders. 6. Remove both covers carefully. To do this, place a screwdriver in recess A to carefully prize the two housing covers apart. 7. Grease O-rings and insert tumbler faucet up to the stop. 20 59 58 470 D 3370 D 3370.031.01.10.02 Sirona Dental Systems GmbH 16 Adapting the Water Unit 16 Adapting the Water Unit båÖäáëÜ 1. D M8 screw (2x) 2. A 1. D 58 71 848 D3370 1. Only if video option is installed: Remove cover A and unscrew the sheet metal support for the video components (4 screws). Lay suction and drain hoses through. Then reattach cover A and the sheet metal support. 2. Fasten the water unit to the chair base with two screws D (M8x20) and washers (do not tighten yet). 59 58 470 D 3370 D 3370.031.01.10.02 21 16 Adapting the Water Unit Sirona Dental Systems GmbH 10 x 160 (2 ea.) 7. M8x20 (2 ea.) 58 71 848 D3370 10 x 80 (2 ea.) 4. 5. A F E F 8. 8. A B 2. / 3. / 6. Grease SYNTHESO PRO AA2 3. 4. Loosen (do not remove) the nuts on screws F of the fixing bracket B. Screw and tighten brackets B on the floor with screws and washers to floor: – With a concrete floor: Use 10 x 160 wood screws – With a wooden floor: Use 10 x 80 wood screws – With the M1 adapter plate (refer also to page 42): Use M10 x18 WARNING Do not secure the water unit by means of the 2 drill holes E. 5. Use a spirit level to vertically align the water unit in all directions and place shimming plate underneath the unit, if necessary. 6. Tighten screws A. 7. Tighten the nuts of screws F. 8. Pull hoses and cables into the junction box area of the chair. 22 i NOTE Adapt the length of the suction and drain hoses to suit local conditions. Cut off pieces of superfluous hose, if any. 9. Grease O-rings and insert the end-piece of the drain hose (small hose diameter) and of the suction hose (large hose diameter). ATTENTION Make sure that the suction pipe is connected as the suction pipe - in other words, not mistaken for the drain. Make sure the drain slopes over its whole length. Do not place other hoses on it. The drain is not required if the water is removed centrally by suction. If the drain pipe is present, you must cover it. 59 58 470 D 3370 D 3370.031.01.10.02 Sirona Dental Systems GmbH 17 Water Unit: Making Connections 17 Water Unit: Making Connections X1 PK CF X2 GY X7 X8 2 1 X7 X3 3. 2. / 6. A båÖäáëÜ 4. X1 5. X99 X8 X33 i Grease SYNTHESO PRO AA2 1. i NOTE If the drain pipe is in an unfavorable position (such as termination panel M1), the drain hose can be moved as illustrated. 20 41 648 29 40 120 17 54 44 018 0mm±10 ! _ 10 100mm + 1. i 2. Connector X33: Insert cable sleeve of electrical lead into correspondingly marked recess of terminal box. Plug in connector. 3. Connector X7 and cable X1: Plug connector X7 into fuse board CF. Connect gray (GY) cable onto X1.1 (board CF) and pink (PK) cable onto X1.2. ATTENTION Make sure you connect the cables the right way around. 4. Insert cable through recess in fuse box and fasten with washer A. 5. Remove connector housing X8 (jumper with marking tag) from board CJ. Plug in connector housing X8 of cable L32 in its place. 6. Plug connector X99 of cable L43 to board CJ. Connect both connector pieces and supply hoses together and secure them with a clamp. NOTE The fronts of the connector pieces must be firmly enclosed by the clip and the clip must engage. 59 58 470 D 3370 D 3370.031.01.10.02 23 18 Adapting the Assistant Element Sirona Dental Systems GmbH 18 Adapting the Assistant Element 58 71 848 D3370 2. 6. 3. 7. 8. 5. 4. i 1. i 2. 1. Fold back the flexible cover. 2. Push the assistant element onto the guide bolts of the slide. The adjustment of the height and swivel stop settings of the support arms is described on pages 49 and 52. 3. Insert two screws with nuts and washers in the plugged connection. 7. Fit the instrument rack and press it downward. The lock must engage. 4. Insert the spacer plates. (2x0.5mm, 1x1mm) 8. Put the tray support in place. i i NOTE NOTE The spacer plates are used to level the assistant element head horizontally. The system-specific tolerances can be compensated for by an empirically determined combination of spacer plates. 5. Tighten the screws. Check with a spirit level to make sure that the assistant element head is level. If necessary loosen the screws again, remove the spacer plate and repeat the procedure until the assistant element is level. 6. Close the cover again. 24 59 58 470 D 3370 D 3370.031.01.10.02 Sirona Dental Systems GmbH 19 Assistant Element: Making Hose Connections 19 Assistant Element: Making Hose Connections 5. 3. W43 1. 2. W32 W32 A34 A39 Version with and without disinfection system 1. A34 W38 A41 A41 4. båÖäáëÜ W43 Pull the nipple holder off from the four-way manifold and plug in the water hose W38 from the assistant element. i NOTE Step 4. also applies to MV33 in combination with a wet suction system. Refit the nipple holder. 2. Pull the nipple holder off from the three-way manifold and plug in the air hose A39 from the assistant element. 5. Arrange the hose connections below the fuse box as illustrated. Refit the nipple holder. ATTENTION Make sure that the nipple holder is firmly seated in the guide grooves of the hose nipples. Check by pulling on the nipples. Stow the manifolds in the rear bottom area. 3. Attach the nipple of the hose W43 to its matching counterpart. Snap on the safety clip. 4. Attach the nipple of the hose A34 to its matching counterpart. Snap on the safety clip. 59 58 470 D 3370 D 3370.031.01.10.02 25 20 Valve set additional units: Making the hose connections Sirona Dental Systems GmbH 20 Valve set additional units: Making the hose connections 310 2. mm W52 1./3. A 1. W52 W32 W32 W38 W52 4. Version with disinfection system Version with disinfection system 1. Version without disinfection system Version without disinfection system Pull the nipple holder off of the four-way distributor. 1. Unscrew hose W52 from quick coupling A (water connection) and pull it off. Pull the blind nipple off of the four-way distributor and fit water hose W52 (from the connection box / valve set). 2. Shorten hose W52 to a length of 310mm. Refit the nipple holder. 3. Plug hose W52 into quick coupling A (water connection) and screw it tight. 4. Unscrew the closing plate from the valve block. Remove the blind nipple, insert hose W52 and screw it onto the closing plate. 26 59 58 470 D 3370 D 3370.031.01.10.02 Sirona Dental Systems GmbH 21 Distributor and Fuse Box 21 Distributor and Fuse Box 3. båÖäáëÜ 2. 1. 1. Screw on cover of fuse box tight. 2. Screw cable holder to distributor box with three screws. 3. Use ohmmeter to measure resistance between points B and C. The value must be ∞. ATTENTION Due to the relevant EMC regulations, the distributor box and all electrical parts must be isolated from all grounded points. i NOTE If in addition a • unit lamp, • tray and/or • Tray with SIVISION 3 monitor have been ordered, they should be installed now (refer to separate installation instructions). 59 58 470 D 3370 D 3370.031.01.10.02 27 22 Attaching the Water Unit Housing Covers Sirona Dental Systems GmbH 22 Attaching the Water Unit Housing Covers A 2. 4. 1. B 3. 6. 5. 2. A 7. D E 4. 1. Remove the lower part of the amalgam separator or of the automatic separator (if installed). 2. Loosen screws A. Slide both aluminum profiles approx. 10 mm outwards. 3. Place the housing cover at an angle on the foot from above and push down. 4. Slide both aluminum profiles over protrusions B in housing cover. Fasten screws A tight. 5. Insert the two side covers in tongue-and-groove joint. 6. Remove the cover from the front housing. Attach front housing cover, inserting it in side covers. First screw on upper screw D loosely (lining up coupling nut if necessary). ATTENTION Make sure that cables and hoses are not pinched behind the domed nuts for screws E. 7. 28 Screw in two lower screws E. Fasten all screws tightly. 59 58 470 D 3370 D 3370.031.01.10.02 22 Attaching the Water Unit Housing Covers 10. 11. 9. båÖäáëÜ Sirona Dental Systems GmbH 8. 8. Remount bottom part of amalgam separator. 9. Sever the cable tie on the motor of the amalgam separator. 10. Slide transport brace with cable tie downward and remove to the rear through opening in chassis. 11. Put on the cup support. 59 58 470 D 3370 D 3370.031.01.10.02 29 22 Attaching the Water Unit Housing Covers Sirona Dental Systems GmbH 14. 13. 12. Serial No. 12. Note Serial No. for Unit Passport. 13. Insert and engage folding cover. 14. Attach inner housing cover at an angle so that it snaps in place. ATTENTION The housing cover must be seated above the lateral tube connector. 30 59 58 470 D 3370 D 3370.031.01.10.02 Sirona Dental Systems GmbH 23 Concluding Work 23 Concluding Work 3. 1. 4. båÖäáëÜ 2. Foot switch C S 5. i NOTE To make the installation easier, the patient chair can be moved up a little (see Operating Instructions). 1. Install the bellows: Pull lower part of bellows over cast-metal frame and press it on with form-fit. 2. Slide in side housing covers. i NOTE Make sure that the housing bearing with the correct serial number is installed. For comparison purposes, check the serial number that is affixed to point S. 3. Use two screws and washers to screw on upper cover plate. 4. Plug on faceplate. Attach the bellows to the foot control. 5. When using foot switch C: Screw on retaining bow of foot switch with two screws. 59 58 470 D 3370 D 3370.031.01.10.02 31 23 Concluding Work Sirona Dental Systems GmbH 6. 7. 7. 8. Grease SYNTHESO PRO AA2 6. Fit the instrument hoses on the dentist element (according to order) from the left to the right: 7. – Plug in the Mini L.E.D. or the hose for surgical suction or SIROCAM 3 / C. ATTENTION Observe the reversal protection on the hose couplings! – Plug on and screw down the hose for SPRAYVIT. – Plug on the suction hose with the upper part of the filter. – Plug on and screw down the hose for SPRAYVIT. – Plug on and screw down the handpiece hoses for the highspeed handpiece and motor. – Plug the saliva ejector hose with the upper part of the filter onto the connecting piece. – Plug on and screw down the hose for the Mini L.E.D. or SIROSONIC L. – Plug on and screw down the hose for the Mini L.E.D. or the connecting cable for SIROTOM and fasten with screws or plug the video camera into the rear panel of the dentist element. Fit the instrument hoses on the assistant element (according to order) from the left to the right: – Attach the corresponding handpieces. ATTENTION Observe the reversal protection on the hose couplings! 8. Attach the connecting hose to the water unit and assistant element. – Attach the corresponding handpieces. 32 59 58 470 D 3370 D 3370.031.01.10.02 Sirona Dental Systems GmbH 24 Final Assembly of the Narrow Backrest 24 Final Assembly of the Narrow Backrest right wrong 1. 4. 6. A C D 7. båÖäáëÜ 3. A 2. 5. B 1. MultiMotion headrest (optional): Attach and press the headrest upholstery on the snap fasteners. 2. Attach and snap on the backrest cover. Fastening straps A must snap onto the studs (with Torx screws) outside of the backrest support. 3. Remove the transport safety devices from the backrest padding. i 7. A With an electrical headrest: Press the Velcro strap in area C uniformly onto catch D. NOTE For details see the paper slip on the upholstery. 4. Hook the padding onto the two upper studs. ATTENTION Risk of upholstery damage! Do not let the upholstery come into contact with edges B when fitting it. 5. Pull the upholstery backing in the lower fastening area downwards and hook it over the lower studs. 6. Affix the adhesive strips of the Velcro strap by pressing them onto the backrest padding. 59 58 470 D 3370 D 3370.031.01.10.02 33 25 Final Assembly of the Wide Backrest Sirona Dental Systems GmbH 25 Final Assembly of the Wide Backrest 1. 3. B 4. 7. 2. D C B 6. 5. A 1. MultiMotion headrest (optional): Attach and press the headrest upholstery on the snap fasteners. 2. Attach and snap on backrest cover. 3. Unscrew backrest padding from cardboard backing. Remove the two red transport safety devices at the right and left of the padding flap. 4. Hook the padding onto the two upper studs (with Torx screws). 5. Pull down the padding backing in the lower hooking area (do not let the padding come into contact with edges A) and hook it onto the lower studs. 6. Press the padding to the right and left sides over the outer contour of the rear cover while holding the cover back with your hand. The padding snap fasteners B must snap into place. The edge contour of the padding towards the rear cover must be uniform. 7. Press the Velcro strap in area C uniformly onto catch D. 34 59 58 470 D 3370 D 3370.031.01.10.02 Sirona Dental Systems GmbH 26 Installing the Seat Padding 26 Installing the Seat Padding 1. D 2. 1. E båÖäáëÜ 1. First press the padding snap fasteners E carefully until they snap into the clamp D. Then insert the seat padding at the foot area into the bracket. 2. Lay the protective cover on top and press uniformly on the Velcro strap. 59 58 470 D 3370 D 3370.031.01.10.02 35 27 Starting up the Treatment Unit Sirona Dental Systems GmbH 27 Starting up the Treatment Unit 5. 9. C + AD1 6. 5. 7. 10. AD2 1. 11. 12. I MA1 2. A 0 MA2 B 4. – + 8. 1. Open the corner valves. 2. Turn ON main switch I. Wait until the end of the self-test (see Operating Instructions). i NOTE Operating pressures for the treatment center have already been set at the factory. MA1: 4.7 bar flowing SPRAYVIT MA2: 2.3 bar flowing SPRAYVIT 3. Check the operating pressures and at AD1 and AD2 as necessary. 4. Check the air and water connections for leaks. 5. Operate all drilling instruments, SIROSON L and both SPRAYVIT syringes in turn until the spray delivered is perfect (see Operating Instructions). Compare and adjust operating air pressures, see next page. 6. Initiate tumbler filling (see Operating Instructions). 7. Initiate cuspidor rinsing (see Operating Instructions). 36 8. Cuspidor rinsing adjustment: Fold open the cover flap on the base. Adjust control nozzle B by turning the knurled wheel until the bottom of the cuspidor bowl is rinsed evenly. Close cover flap again. 9. If the customer wishes, the factory set suction power can be adjusted at control nozzle C. 10. Check the return swivel movement of the cuspidor bowl: – swing the cuspidor bowl into area traversed by the chair – in succession, press the chair button and trigger the chair program – the cuspidor bowl must swing automatically back into its initial position 11. Mount cover. And fasten it using two screws and washers. Plug on base cover A. 12. Put on the outer housing and click in place. 59 58 470 D 3370 D 3370.031.01.10.02 Sirona Dental Systems GmbH 28 Compare and adjust operating air pressures 28 Compare and adjust operating air pressures RL TL i båÖäáëÜ SL SW EL 1, motor SL NOTE The operating pressures for the instruments are set before they leave the factory. The settings for propellant air and spray air can be changed if the customer so desires. Precise adjustment of the propellant and spray air pressures is possible using the 4-on-1 probe (Order No. 36 66 336). Factory settings for running turbine: The cooling air pressure for the motor results from the driving air setting of the turbine. A turbine has to be fitted instead of the motor for setting. For setting refer to page 38. i NOTE TL = propellant air SW = spray water SL = spray air RL = return air Turbines: T1 Control, TC1 and TC3, TM1 TITAN: Propellant air (shown on the display) 3.5 bar ± 0.1 bar Propellant air at 4-on-1 probe (TL) 2.7 bar ± 0.1 bar Spray air at 4-on-1 probe (SL) 2.7 bar ± 0.1 bar 59 58 470 D 3370 D 3370.031.01.10.02 37 28 Compare and adjust operating air pressures Sirona Dental Systems GmbH SL TL RD5 C - V + D BS M S B A Setting the Air Pressures Propellant air • Repeat setting for other holders. • Close the unit head: – Take out the instruments and remove the instrument tray. The setting is performed separately for each turbine on the chip BS concerned. • Take the instruments from their holders. • Press down two catches A and remove the instrument tray. – Fold down the unit head and install screws B. When installing the unit head, make sure that is centered with respect to the chassis so that gaps of identical size are created when the instrument tray is mounted. • Loosen screws B. • Lift back the unit cover C, and secure with the upright retaining device D. • Set down the instrument tray temporarily and return the instruments to their holders (photelectric light barrier detection must function). Spray air • Connect the 4-on-1 probe. Remove the turbine and screw 4-on-1 probe V between the turbine and hose. • Undo union nut M. • Using a screwdriver, set spray air pressure SL as required by the customer by turning screw S. • Tighten union nut M • Check the settings and readjust if necessary. • Remove the 4-on-1 probe. • • Start the turbine with the foot switch. • Set the pressure of the propellant air at RD5 with a screwdriver. Do not undo the screw further than to the level of the plastic collar. 38 – Put the instrument tray in place and lay the instruments on it. 59 58 470 D 3370 D 3370.031.01.10.02 Sirona Dental Systems GmbH 29 Checking the Safety Switches båÖäáëÜ 29 Checking the Safety Switches Performance of safety tests 1. Prior to handover of the treatment center, a number of safety tests must be performed. They are described in the Maintenance Manual. The values measured during initial start-up must be documented there. Checking the safety switches 2. • Swing in the swiveling cuspidor : The chair movement stops. ATTENTION If one of the safety switches does not stop the chair movement or the backrest movement, the treatment center must not be used for dental work! The fault must be eliminated before handing the treatment center over to the customer. Check the safety switches installed in the unit. Lower the chair and the backrest. • Lift the leg support: The chair movement stops, then there is a corrective movement upwards for about 3s. • Lift the backrest: The backrest movement stops, then there is a corrective movement upwards for about 3s. • Raise the motor-adjustable headrest: The backrest movement stops, then there is a corrective movement upwards for about 3s. 59 58 470 D 3370 D 3370.031.01.10.02 39 30 For the Customer … Sirona Dental Systems GmbH 30 For the Customer … 2. 1. 3. Th 1. e D en ta l C om pa ny Am Amalg a Ro alg m-R a Rotor m R oto to d’a oto r rd m e a alg r m am alg e am a Modell/SerialNr. Mad e in Germ any 1. Installation report/warranty passport: • The serial numbers from the – dentist element, – assistant element, – water unit, – chair, – lamp, – monitor – SIROCAM 3 / SIROCAM C, must be entered in the "Installation report/warranty passport" document. • Enter the equipment of the dentist element. • Complete the installation report • Complete the remaining lines with the customer. • Hand over the CUSTOMER'S COPY to the customer. The DEALER'S COPY is for the customer records kept by the dealer. 2. Dealer: Please fax the DEALER'S COPY to Sirona directly after the installation. 40 ATTENTION Please note that any warranty claims can be fulfilled only if the completely and legibly completed "Installation report/warranty passport" document is available at Sirona directly after the installation! 3. For the Customer … Accessories (depending on order): The accessories shown above for sanitization, water unit, assistant element and for the thermo-disinfectable supply hoses must be handed over to the customer. 59 58 470 D 3370 D 3370.031.01.10.02 Sirona Dental Systems GmbH 30 For the Customer … båÖäáëÜ 4. C2+C5+ 5. 4. Sanitization: Needs to be agreed with the customer. Prior to initial startup, the water paths must be sanitized with DENTOSEPT P as described in the instructions for Care and Maintenance by the Practice Team. – If the customer needs the station for patients within a week, you as the installation engineer have to initiate sanitization. – If the customer does not need the station for patients until later, the customer has to sanitize the water system one day before using the station. 5. Technical documents – Keep the CUSTOMER'S COPY of the unit passport together with the other technical documents. – The operating instructions supplied with the treatment instruments should be kept in the plastic jakket provided. ATTENTION The supplied technical documents are an important part of the delivered unit and are thus to be handed out to the customer. The technical documents must be kept by the customer. 59 58 470 D 3370 D 3370.031.01.10.02 41 31 Fastening the Chair to the Floor with the M1 Adapter Plate Sirona Dental Systems GmbH 31 Fastening the Chair to the Floor with the M1 Adapter Plate S 5. M 4. 3. M D 2. 5. A KS 1. Align the adapter plate with the M1 connection panel. 2. Use the existing drill holes (3) to secure the adapter plate. – With a concrete floor: Use 10 x 160 wood screws and washers. 10x160 10x80 H G K E F 58 71 848 D3370 B C 1. 5. Screw protective ground conductor S to the M1 adapter plate and the bottom of the chair (do not forget contact plate KS). • Continue with installing the chair at the section entitled “Connecting Air and Water” on page 15 – With a wooden floor: Use 10 x 80 wood screws and washers. 3. Grasp the chair in the area near M, lift it from the pallet and position it on the adapter plate. ATTENTION Do not lift the chair by its backrest or by the bracket for the upholstery. 4. i Fasten the chair to the adapter plate at points A, B, D, E and K with the M10 x 18 screws. NOTE The chair must be fastened at positions C and H, after the electrical connection has been made. The chair can then be moved upward with the foot control (refer to page 18 ). 42 59 58 470 D 3370 D 3370.031.01.10.02 Sirona Dental Systems GmbH 32 Settings on Dentist and Assistant Elements 32 Settings on Dentist and Assistant Elements båÖäáëÜ 2. 1./3. Readjusting the Height on the Dentist and Assistant Elements If the customer so wishes, the height setting on the dentist and assistant elements can be readjusted. i NOTE Lift the support arm slightly to loosen the adjusting screw. 1. Loosen the adjusting screw. 2. Adjust to the height desired by the customer or in keeping with room conditions. 3. Retighten the adjusting screw. 59 58 470 D 3370 D 3370.031.01.10.02 43 32 Settings on Dentist and Assistant Elements Sirona Dental Systems GmbH Figure X A A 5. 5. A 4./6. Torx 15 5. 5. Torx 15 Torx 15 Braking effect at the head of the dentist element At the customer's request, the braking effect of the rotary joint at the head of the dentist element can be adjusted. 4. i Remove the covering of the support arm. NOTE To illustrate the position of the setscrews A more clearly, the brake is shown without attachment parts in figure X. 5. Adjust the setscrews A equally until the braking force corresponds to the customer's wishes. 6. Reattach the covering. 44 59 58 470 D 3370 D 3370.031.01.10.02 Sirona Dental Systems GmbH 32 Settings on Dentist and Assistant Elements 10. 13. 7. båÖäáëÜ 8./14. 10./ 11. C D 12. B 9. Swivel Stops on Dentist and Assistant Elements If the customer so wishes, two swivel stops on both the dentist and and the assistant element can be readjusted. ATTENTION In order to avoid damage to the dentist and assistant elements and to the chair upholstery, make sure that these elements do not protrude into the area through which the chair moves. 10. Turn the support arm so that one screw of the end stop can be seen through hole C or D. Loosen screw. Continue rotating the support arm until the second screw can be seen. Loosen screw. Adjust the first stop in accordance with customer's wishes. 11. Tighten down both screws. • To adjust the second stop, repeat steps 10. and 11. in an identical fashion. • Lower the chair and the backrest as far as it will go. 12. Push down stop pin. Retighten screw B. 7. Remove the inner paneling. 13. Reattach paneling. 8. Loosen the adjusting screw on the support arm (refer to page 43). Lower the support arm as far as it will go. 14. Place the support arm at the height required and tighten the adjusting screw. i NOTE To illustrate the point, the figure shows the support arm without paneling for steps 9. to 12. 9. Loosen screw B. Push stop pin upwards. 59 58 470 D 3370 D 3370.031.01.10.02 i NOTE To set the stop of the assistant element towards the water unit, the assistant element must be separated from the chair base, since only then are the screws of the stops accessible. 45 33 Changing Function on "C" Foot Switch Sirona Dental Systems GmbH 33 Changing Function on "C" Foot Switch 1. 3. 2. Setting ex factory: All functions of the foot switch are triggered by operating the pedal at A (for example, starting of the dental instruments). If the customer wants to trigger the functions by operating the pedal at B, the slide switch S5 in the foot switch can be changed as follows: 1. Fold up the rubber hood at the front right corner of the pedal. 2. Using a screwdriver, push the slider of switch S5 to the right (hole in the pedal). 3. Reattach the rubber cover. Press the knobs C tightly into the holes. ATTENTION The complete edge of the rubber hood must be turned over the sealing lip D of the lower rubber cover. 46 59 58 470 D 3370 D 3370.031.01.10.02 Sirona Dental Systems GmbH 34 Demonstration Unit without Water Connection 34 Demonstration Unit without Water Connection X5 2. Ass. el. 1. båÖäáëÜ Dent. el. X5 MV1 gn /ge gn /ge L N L N 3. 1. Unplug connector X5 of SPRAYVIT power supply leads from dentist element (board ADX). 2. Unplug connector X5 of SPRAYVIT power supply leads from assistant element (board HP). 3. For water unit with disinfection system only: Strip and insulate the electric cables in the chair at solenoid valve MV1. 59 58 470 D 3370 D 3370.031.01.10.02 47 35 Packing Position Sirona Dental Systems GmbH 35 Packing Position 650 mm 300 mm To repack the chair (for example, for transportation to an exhibition), move it to the position shown. i NOTE Should the chair be moved after the water unit and the assistant element are already dismantled, the short-circuit plugs X8 and X90 on the connection box PC board CJ must be reinserted (see chapter “Water Unit: Making Connections” on page 23 . 48 59 58 470 D 3370 D 3370.031.01.10.02 Sirona Dental Systems GmbH 36 Reversing the Direction of the Travel Track 36 Reversing the Direction of the Travel Track R6.2 R6.1 4. br A 3. 1. båÖäáëÜ 3 21 2. 5. R6 ATTENTION Unplug the unit! 1. Pull off and swap the positions of the connectors for the white and brown leads at the travel track drive (white in place of brown and brown in place of white). 2. Pull off socket casing R6 from the reversing block. 3. Press lightly on spring clamp A on R6.1 and R6.2 and detach the cores. 4. Press the spring clamps up slightly and attach the cores again in reverse (white to R6. 2 and green to R6.1). 5. Attach socket housing R6 again. 59 58 470 D 3370 D 3370.031.01.10.02 49 tÉ=êÉëÉêîÉ=íÜÉ=êáÖÜí=íç=ã~âÉ=~åó=~äíÉê~íáçåë=ïÜáÅÜ=ã~ó=ÄÉ=êÉèìáêÉÇ=ÇìÉ=íç=íÉÅÜåáÅ~ä=áãéêçîÉãÉåíëK «=páêçå~=aÉåí~ä=póëíÉãë=dãÄe=OMMT a=PPTMKMPNKMNKNMKMO===NMKOMMU péê~ÅÜÉW=ÉåÖäáëÅÜ= ûKJkêKW= NNM=SQQ mêáåíÉÇ=áå=dÉêã~åó fãéêáã¨=Éå=^ääÉã~ÖåÉ páêçå~=aÉåí~ä=póëíÉãë=dãÄe áå=íÜÉ=rp^W c~Äêáâëíê~≈É=PN SQSOR=_ÉåëÜÉáã dÉêã~åó ïïïKëáêçå~KÅçã páêçå~=aÉåí~ä=póëíÉãë=ii` QUPR=páêçå~=aêáîÉI=pìáíÉ=NMM `Ü~êäçííÉI=k`=OUOTP rp^ lêÇÉê=kç RV=RU=QTM=a=PPTM