VERIFY IN FIELD
LEGENDS
1
WALL TYPES
TYPE
EXIT LIGHT W/BATTERY BACK UP
EMERGENCY W/BATTERY BACK UP
TYPE
1
ELEC.PANEL "L"
TOTAL PROJECT AREA: 1,030 S.F.
MOP
OFFICE
:TILE
CONN PL W/ BOLT TYP
JANITOR CLOSET N2
:TILE
CEILING
1
3
1
N3
WH
ANGLE BRACE @48" O.C. MAX
AT ALTERNATE SIDES
PL W/STUDS
KITCHEN
:TILE
CEILING AS PER SCHEDULE
MEN
:TILE
4 5/8" W METAL STUDS
@24" O.C.
CORRIDOR
:TILE
PLAN
N3
1
1
1/2" GYPSUM WALL BOARD ON EA. SIDE
1
3-1/2" METAL STUDS
1
F
PROJECT NAME:
MILAN
CAFETERIA
LOST & FOUND
:TILE
PROJECT LOCATION:
3819E S GEORGE MASON DR
BAILEYS CROSSROADS VA 22041
BASE, REF. TO SCHEDULE
FLOOR
CONTINUOUS SEALANT
N2
FLOOR
N2
1. PROVIDE MOISTURE RESISTANT GYP. BD. AT RESTROOM,JANITOR CLOSET
AND KITCHEN AREA
2. INSTALL GYP. BD. CONTROL JOINTS AS NEEDED TO PREVENT CRACKING
3. PROVIDE FINISHES PER ROOM FINISH SCHEDULE ON SHEET CO.
1
VERIFY IN FIELD
REMARKS
WOMEN
:TILE
SEAL:
F
WALL BRACING
@3-1/2" METAL STUDS
SYN.AMEP@GMAIL.COM
HOOKAH BOOTH
(SMOKING AREA)
:TILE
4
1
VERIFY IN FIELD
EXIST. WALL TO REMAIN
CASHIER
:TILE
EQUIPMENT SCHEDULE
MANUFACTURER
DATE:
1
CASH REGISTER
2
MERCHANDISER REFRIGERATOR
BEVERAGE-AIR / MT23-1B
3
ESPRESSO MACHINE
CIME / CO-01
4
BLENDER
AVAMIX / 928BX2000T
NSF
5
1 COM SINKS WITH SIDE BOARD
REGENCY / 600S1181818XRT
NSF
6
HAND SINK W/SIDE SPLASH GUARD
-
7
3 COM SINKS W/ SIDE BOARD
STEELTON / 522CS31620LR
8
SS WORKTABLE
9
WATER HEATER
10
1 DR REFRIGERATOR
11
UNDERCOUNTER ICE MACHINE
12
WALL MTD S/S WIRE SHELVE
13
HOOKS FOR EMPLOYEE'S BELONGINGS
01/28/22 REV1
1
UL
34"H MAX
ADA COUNTER
NSF
WAITING AREA
:TILE
SEE MECHANICAL PLANS FOR DETAILS
AVANTCO / 194UC120A
NSF
NOTES:
·
ALL EQUIPMENT SHALL BE FURNISHED BY THE OWNER AND INSTALLED BY CONTRACTOR.
·
CONTRACTOR SHALL FURNISH ALL REQUIRED CONNECTION APPARATUS NOT SUPPLIED BY EQUIP.
SUPPLIER FOR FINAL CONNECTION.
·
CONTRACTOR SHALL VERIFY ALL EQUIPMENT REQUIREMENTS PER MANUFACTURER'S SPECIFICATION.
·
ALL WASTE DRAINS FROM EQUIPMENT IN WHICH FOOD, UTENSILS OR PORTABLE EQUIPMENT MAY BE
1 F
N1
VESTIBULE
:TILE
METAL FRAME
FIXED WITH
TEMPERED GLASS (1/4")
PARTITION WALLS
FLOOR PLANS &
EQUIPMENT LIST
SHEET #:
2
E1
DISCLAIMER:
ALL COUNTER MOUNTED EQUIPMENT MUST BE INSTALLED ON 4" LEGS, BE SEALED TO THE COUNTER OR
BE EASILY MOVABLE.
GENERAL NOTES
EX. 3'L FRONT DOOR
AND STORE FRONT
TO REMAIN
ALL FLOOR-MOUNTED EQUIPMENT MUST BE INSTALLED ON 6" LEGS, ROLLERS, A RAISED PLATFORM OF
CONCRETE OR BE SEALED TO THE FLOOR AND WALL, IF INSTALLED ALONG A WALL.
SCALE:
SHEET TITLE:
WASTE SYSTEM BY MEANS OF AIR-GAP OR AIR-BREAK.
·
1
3/8" = 1'-0"
DINING AREA
:TILE
PLACED, SUCH AS PREP SINKS, 3 COMPARTMENT SINKS ETC., MUST BE INDIRECTLY CONNECTED TO THE
·
ISSUE:
REMARK
EX. 1HR FIRE RATED
DEMISING WALL(UL U419)
ITEM
ADJACENT TENANT
MARK
ADJACENT TENANT
·
CONSULTANT:
1
PROPOSED FLOOR PLAN
3/8" = 1'-0"
1 PORTABLE FIRE EXTINGUISHERS TO BE LOCATED PER SECTION 906 OF
THE VCC, 2018
2 EXISTING ACCESSIBLE DOOR WITH NEW PANIC HARDWARE TO BE
INSTALLED.
3 PROVIDE S/S PANELING UP TO SPLASH LEVEL.
4 PROPER RESTROOM SIGNAGE WILL BE PROVIDED
FOR CUSTOMER USE.
THESE DRAWINGS, IDEAS,
SPECIFICATIONS AND DESIGNS ARE
EXCLUSIVE PROPERTY OF SYN
ARCHITECTURE & ENGINEERING LLC.
NO PART OF THESE DRAWINGS MAY BE
COPIED, REPRODUCED, OR OTHER
STRUCTURES BUILT FROM SUCH WITHOUT
THE WRITTEN CONSENT OF SYN
ARCHITECTURE & ENGINEERING LLC.
SYN ARCHITECTURE & ENGINEERING LLC
ALL RIGHTS RESERVED
Download