VERIFY IN FIELD LEGENDS 1 WALL TYPES TYPE EXIT LIGHT W/BATTERY BACK UP EMERGENCY W/BATTERY BACK UP TYPE 1 ELEC.PANEL "L" TOTAL PROJECT AREA: 1,030 S.F. MOP OFFICE :TILE CONN PL W/ BOLT TYP JANITOR CLOSET N2 :TILE CEILING 1 3 1 N3 WH ANGLE BRACE @48" O.C. MAX AT ALTERNATE SIDES PL W/STUDS KITCHEN :TILE CEILING AS PER SCHEDULE MEN :TILE 4 5/8" W METAL STUDS @24" O.C. CORRIDOR :TILE PLAN N3 1 1 1/2" GYPSUM WALL BOARD ON EA. SIDE 1 3-1/2" METAL STUDS 1 F PROJECT NAME: MILAN CAFETERIA LOST & FOUND :TILE PROJECT LOCATION: 3819E S GEORGE MASON DR BAILEYS CROSSROADS VA 22041 BASE, REF. TO SCHEDULE FLOOR CONTINUOUS SEALANT N2 FLOOR N2 1. PROVIDE MOISTURE RESISTANT GYP. BD. AT RESTROOM,JANITOR CLOSET AND KITCHEN AREA 2. INSTALL GYP. BD. CONTROL JOINTS AS NEEDED TO PREVENT CRACKING 3. PROVIDE FINISHES PER ROOM FINISH SCHEDULE ON SHEET CO. 1 VERIFY IN FIELD REMARKS WOMEN :TILE SEAL: F WALL BRACING @3-1/2" METAL STUDS SYN.AMEP@GMAIL.COM HOOKAH BOOTH (SMOKING AREA) :TILE 4 1 VERIFY IN FIELD EXIST. WALL TO REMAIN CASHIER :TILE EQUIPMENT SCHEDULE MANUFACTURER DATE: 1 CASH REGISTER 2 MERCHANDISER REFRIGERATOR BEVERAGE-AIR / MT23-1B 3 ESPRESSO MACHINE CIME / CO-01 4 BLENDER AVAMIX / 928BX2000T NSF 5 1 COM SINKS WITH SIDE BOARD REGENCY / 600S1181818XRT NSF 6 HAND SINK W/SIDE SPLASH GUARD - 7 3 COM SINKS W/ SIDE BOARD STEELTON / 522CS31620LR 8 SS WORKTABLE 9 WATER HEATER 10 1 DR REFRIGERATOR 11 UNDERCOUNTER ICE MACHINE 12 WALL MTD S/S WIRE SHELVE 13 HOOKS FOR EMPLOYEE'S BELONGINGS 01/28/22 REV1 1 UL 34"H MAX ADA COUNTER NSF WAITING AREA :TILE SEE MECHANICAL PLANS FOR DETAILS AVANTCO / 194UC120A NSF NOTES: · ALL EQUIPMENT SHALL BE FURNISHED BY THE OWNER AND INSTALLED BY CONTRACTOR. · CONTRACTOR SHALL FURNISH ALL REQUIRED CONNECTION APPARATUS NOT SUPPLIED BY EQUIP. SUPPLIER FOR FINAL CONNECTION. · CONTRACTOR SHALL VERIFY ALL EQUIPMENT REQUIREMENTS PER MANUFACTURER'S SPECIFICATION. · ALL WASTE DRAINS FROM EQUIPMENT IN WHICH FOOD, UTENSILS OR PORTABLE EQUIPMENT MAY BE 1 F N1 VESTIBULE :TILE METAL FRAME FIXED WITH TEMPERED GLASS (1/4") PARTITION WALLS FLOOR PLANS & EQUIPMENT LIST SHEET #: 2 E1 DISCLAIMER: ALL COUNTER MOUNTED EQUIPMENT MUST BE INSTALLED ON 4" LEGS, BE SEALED TO THE COUNTER OR BE EASILY MOVABLE. GENERAL NOTES EX. 3'L FRONT DOOR AND STORE FRONT TO REMAIN ALL FLOOR-MOUNTED EQUIPMENT MUST BE INSTALLED ON 6" LEGS, ROLLERS, A RAISED PLATFORM OF CONCRETE OR BE SEALED TO THE FLOOR AND WALL, IF INSTALLED ALONG A WALL. SCALE: SHEET TITLE: WASTE SYSTEM BY MEANS OF AIR-GAP OR AIR-BREAK. · 1 3/8" = 1'-0" DINING AREA :TILE PLACED, SUCH AS PREP SINKS, 3 COMPARTMENT SINKS ETC., MUST BE INDIRECTLY CONNECTED TO THE · ISSUE: REMARK EX. 1HR FIRE RATED DEMISING WALL(UL U419) ITEM ADJACENT TENANT MARK ADJACENT TENANT · CONSULTANT: 1 PROPOSED FLOOR PLAN 3/8" = 1'-0" 1 PORTABLE FIRE EXTINGUISHERS TO BE LOCATED PER SECTION 906 OF THE VCC, 2018 2 EXISTING ACCESSIBLE DOOR WITH NEW PANIC HARDWARE TO BE INSTALLED. 3 PROVIDE S/S PANELING UP TO SPLASH LEVEL. 4 PROPER RESTROOM SIGNAGE WILL BE PROVIDED FOR CUSTOMER USE. THESE DRAWINGS, IDEAS, SPECIFICATIONS AND DESIGNS ARE EXCLUSIVE PROPERTY OF SYN ARCHITECTURE & ENGINEERING LLC. NO PART OF THESE DRAWINGS MAY BE COPIED, REPRODUCED, OR OTHER STRUCTURES BUILT FROM SUCH WITHOUT THE WRITTEN CONSENT OF SYN ARCHITECTURE & ENGINEERING LLC. SYN ARCHITECTURE & ENGINEERING LLC ALL RIGHTS RESERVED