Leading LED Applications XD6/XD10 User Manual Table of Contents 1. Product Introduction 2. Product Components 3. Product Installation 4. Product Wiring 5. Maintenance Safety information WARNING! Please read the Safety Measures listed in this section carefully before installing, switching on, operating and maintenance of this product. The following marks on the product and in this manual indicate important safety measures. WARNING! Safety Risk! Might cause equipment damage Or safety risk WARNING! Please read the manual before operating WARNING! Dangerous Voltage! Might cause equipment damage or electric shock WARNING! Hot Surface! Do not touch WARNING! Flammable! WARNING! Possible damage to eyes Warning: Be sure to understand and follow all safety guidelines, safety instructions, warnings and precautions listed in this manual. This product is for professionals use only! This product may result in serious injury or death due to fire hazard, electric shock or on dropping. Please read this manual carefully before installing, powering up, operating and maintenance of this product. Follow safety instructions in this manual and on the product. If you have any questions, please seek help from Absen. Beware of Electric Shock! To prevent electric shock the device must be properly grounded during installation. Do not ignore using the grounding plug, or else there is a risk of electric shock. During a lightning storm, please disconnect the device’s power supply, or provide other suitable lightning protection. If the equipment is not in use for a long time, please unplug the power cord. When performing any installation or maintenance work (e.g. removing the fuses, etc.,) make sure to turn off the master switch. Disconnect AC power when the product is not in use, or before disassembling, or installing the product. The AC power used in this product must comply with local building and electrical codes, and should be equipped with overload and ground fault protection. The main power switch should be installed at a location near the product and should be clearly visible and easily reached. This way in case of any failure the power can be promptly disconnected. Before using this product check all electrical distribution equipment, cables and all connected devices, and make sure all meet current requirements. Use appropriate power cords. Please select the appropriate power cord according to the required power and current capacity, and ensure the power cord is not damaged, aged or wet. If any overheating occurs, replace power cord immediately. For any other questions, please consult a professional. Beware of Fire! Use a circuit breaker or fuse protection to avoid fire caused by power supply cables overloading. To avoid fire caused by power supply cables overloading, do not connect to the same power supply point for more than 4 cabinets at a voltage of 100-120V, or 8 cabinets at a voltage of 200-240V. Maintain good ventilation around the display screen, controller, power supply and other devices, and keep a minimum 0.1 meter gap with other objects. Do not stick or hang anything on the screen. Do not modify the product, do not add or remove parts. Do not use the product in case ambient temperature is over 55 ℃. Beware of Injury! Warning: Wear a helmet to avoid injury. Ensure any structures used to support, fix and connect the equipment can withstand at least 10 times the weight of all the equipment. When stacking products, please hold products firmly to prevent tipping or falling. Ensure all components and steel frames are securely installed. When installing, repairing, or moving the product, ensure the working area is free of obstacles, and ensure the working platform is securely and stably fixed. In the absence of proper eye protection, please do not look directly at the lit screen from within a 1 meter distance. Do not use any optical devices that have converging functions to look at the screen to avoid burning the eyes. WARNING: Beware of suspended loads. LED lamps used in the module are sensitive and can be damaged by ESD (electrostatic discharge). To prevent damage to LED lamps, do not touch when the device is running or switched off. WARNING: The manufacturer shall not bear any responsibility for any incorrect, inappropriate, irresponsible or unsafe system installation. Product Disposal Any component that has a recycling bin label can be recycled. For more information on collecting, reusing and recycling, please contact the local or regional waste management unit. Please contact us directly for detailed environmental performance information. Product Introduction About the product The series are a breakthrough from traditional products, innovatively using independent waterproof modules, and designed with smart monitoring system. The products support front and rear installation and maintenance, have a simple design, excellent display effect, high stability, and provide easy and convenient installation and maintenance. Product Specifications Parameter XD6 XD10 Pixel Configuration Pixel Pitch (mm) Pixel matrix per panel Physical Parameter SMD2727 6.66 10 96×144 64×96 Module Dimensions (LxW)/(mm) 320×320 Panel Dimensions (LxWxH)/(mm) 640×960×106 Panel material Electronic Parameter Panel weight (kg) 21 Color Grayscale (Bit) 16 Refresh Rate(Hz) Driving Type Optical Parameter Aluminum 1920 3840 1/6 1/2 Brightness(cd/m2) 6000 Color Temperature(K) 7500 Color Contrast Viewing Angle (H/V) (°) 7000:1 6500:1 160/100 160/110 AC Input Voltage(V) Electrical 100~240 Power Consumption Max.(W/m²) 630 660 Power Consumption Avg.(W/m²) 210 220 Parameter Circumstan Storage Temperature(℃) ﹣40~﹢60 Operating Temperature(℃) ﹣20~﹢50 Storage Humidity(RH) 10﹪~90﹪ Operating Humidity(RH) 10﹪~90﹪ IP rating (Front/Rear) IP65/IP54 ce Parameter Lifetime Typical Value(hrs) 100000 Key Product Selling Points Panel weight is only 21kg, easy delivery and installation Panel thickness is 106mm,saving your installation space. Without any monitoring card and data wire can realize monitor display working status, realtime to monitoring sending card, receiving card, module, module connection, temperature ,voltage& etc. Smart Modules: Module can store ID number, production date, order information, usage duration, color coordinates, current and other information. More convenient and practical.Front and Rear cabinet installation: Convenient front installation design ensures screen maintenance without servicing channel at the back, saving space. Built-in standard mounting holes ensures easy rear installation. Front & Rear maintenance design for individual components: modules, controlling cards and power unit. External test button, enables simple test just by pressing the button. No cables design, simple and convenient, saving cost. Module data and power supply adopt parallel connecting, one module failure, will not effect others. Adopt SMD2727 LED, higher contrast ratio, XD6 5000:1, XD10 6500:1. Product Dimensions Product Components Cabinet Introduction Installation hole Distribution box Positioning Column Handle Test button Module Distribution box loc Modules Packaging Carton Packing Wooden case packing Note: Wooden packing is recommended for long-distance transportation. Installation-use connecting plates and bolts Connecting plates M8x10 Bolt Product Installation Installation Types Outdoor fixed mounted LED display can be installed in the following 6 types. Please select appropriate installation type as per site environment: Preparation work before installation Outdoor LED display frame design should minimize structural weight, while ensuring sufficient mounting strength and should look good. 1. Before installing the cabinet, please check if the steel structure parameters are appropriate: • Bottom structure should be stable and solid. • Is the structure width and height appropriate? • The distance between the 2 square hollow bars (or angle iron) should be the same (when cabinet size is the same). • Is the maintenance-channel position appropriate? Check if it is blocking disassembly and maintenance of power distribution box and modules. • Steel structure welding should be firm and complete, surface appearance should be nice and even. 2. Installation order for the cabinets should start from center moving to both sides, and from bottom to top, according to the number of cabinets. Installation methods are as follows. • Gently lift and place the cabinets. Be careful not to damage the LED and cabinet structure. • Control the installation gap between cabinets. Generally keep within 2mm. • After finishing each cabinet row, make sure it is stable and horizontal at the same level before installing an upper row. Cabinet Installation Cabinet Front Installation Remove the corner modules Set up the corner modules Convenient front installation design enables fast installation without maintenance-channel at the back of the display, greatly saving space. Cabinet Rear Installation Mounting fixing holes *4 Product comes with standard mounting holes, easy for rear installation. Cabinet Installation Method Produce steel structure according to different installation method (Take column installation for example) as shown below: Cabinet installation sequence: First install the middle cabinet followed by the two sides (see below): Use connecting plates and bolts to fix the cabinet onto the square hallow bar (as shown below): After completing one row of cabinets’ installation, start installing the next upper row of cabinets. (See below): Decorate appropriately after the cabinets’ installation is finished. (See below) Product Wiring Power Cable Wiring • Preparation before wiring Before connecting to power supply and switching on control signal to the entire screen, please carefully check the power supply and signal cable connections. Please carefully check the "L" line, "N" line and "PE" of each cabinet’s AC inlet, and ensure there is no short circuit between the three lines (Use multimeter to measure). • Power cable wiring description Please calculate and select the appropriate distribution box model according to the maximum power consumption of XD6 630 W/m2, XD10 660W/m2. Please consult your distribution box manufacturer for the specific options. The cabinet’s input voltage is 100-240 V/AC. Select the distribution box according to the display’s total power. When the display’s total power is larger than 10 KW, it is generally recommended to use 3-phase 5-wire 380 V/190V input electricity to the distribution box, then output 220V/110V single-phase electricity from the distribution box to supply power for the display: Note: Lightning proof device, timers, AC contactor, current and voltage sensors are optional as per requirement. Use 3X2.5 mm2 cable to connect from distribution box to cabinet. When input power supply is 220V, each power cable can support maximum 8 cabinets’ load; when input voltage is 110V, each power cab can support maximum 4 cabinets’ load. Take XD6 product 6x4 cabinets for example. Following are instructions for power and signal cables connection method: Power cabling: Total power for 24 units of 640x960mm cabinets is 24x0.64x0.96x630W = 14.7KW. Taking into account surplus requirement and lighting electricity, select a 20 KW main distribution box. The main cable uses 3-phase 5-wire 380V input to the main distribution box. Use 3x2.5 mm 2 power cable to connect from distribution box to the display. Connect each row of 6 cabinets with power cable in series, and then connect the power distribution box to the first cabinet. Power cable can be connected from the left or right cabinet, as shown below: 3X2.5mm² 20KW Distribution Box Network Cabling Cat 5 USB cable Sending card DVI cable Based on actual situation, network cables can be connected in left-right "Z" type or up-down "S" type format. Please connect the signal cables according to each cabinet’s pixels: XD6 (96x144), XD10 (64x96), as per the load range of the transmission card. Please note that the load pixel range of each network interface should be no more than 650,000 pixels. Maintenance Preparation Tools Tools needed include: Allen wrench, Phillips screwdriver, a Multimeter, module front maintenance tools, etc. Module Front Maintenance Insert tool into Loosen screws the maintenance hole Disassemble the module Module Rear Maintenance Loosen screws Push the module Disassemble the module Front Maintenance for Power box Rear Maintenance for Power box Check Power Supply Short Circuit After completing the cabinet wiring, please use a multimeter to measure if there is any short circuit at the AC input power supply (L / N / PE) and DC output terminal (VCC / GND). If there is a short circuit, please carefully investigate the wirings. Make sure all wirings are normal, and only then connect power to operate the unit.