NDE PLAN EXTENT OF NDE TYPE PF WELD SL. NO. 1 2 4 5 6 7 8 FULL PENETRATION BUTT WELD FULL PENETRATION BUTT WELD BRANCH CONNECTIONS AND FILLET WELDS ATTACHMENTS WITH FULL/PARTIAL PENETRATION WELDS & FILLET WELDS TEMPORARY ATTACHMENTS WITH FULL PENETRATION OR PARTIAL PENETRATION & FILLET WELDS NA (JOINT DISCRIPTION) ALL CIRCUMFERENTIAL WELD JOINTS (BARREL TO REDUCER/FLANGE/QOEC) WELDOLET TO FLANGE JOINTS NOZZLE TO SHELL JOINTS TYPE OF NDE REMARKS BEFORE FIT UP AFTER WELD MT/PT 100% (BEVEL EDGE) 100% RT NA 100% VT 100% 100% MT/PT 100% (BEVEL EDGE) 100% RT NA 100% VT 100% 100% MT/PT 100% (BEVEL EDGE) 100% MT RT NA NA VT 100% 100% MT NA 100% VT 100% 100% MT NA 100% VT 100% 100% MT NA 100% VT 100% 100% U.T.L 100% NA PERMANENT ATTACHMENTS PRESSURE RETAINING AREAS AFTER REMOVAL OF TEMP. ATTACHMENTS & WELDINGGRINDING AREAS Lifting lugs Lifting lug area Lifting lug to plate welds shall be subjected to UT where accessible.