Uploaded by zhanbulat1964

vm7035t cp

advertisement
General
Information
Explosion Proof Motors
Single and
Three Phase,
C-Face
1/4 thru 50 Hp
NEMA 56C thru 326TC
Single Phase
Motors
Applications: Ideal for use on pumps, blowers, valves, and gearboxes where
hazardous fumes and dust are present requiring Div 1 UL listed and/or CSA
approved enclosures.
General Purpose
Industrial Motors
Features: UL & CSA approved for Class I, Group D; Class I, Group D, Class
II, Group F & G. Totally enclosed heavy gauge steel and cast iron construction.
Corrosion resistant epoxy paint. Single and Three Phase designs. 1.0 Service
Factor. Three Phase 143T frame and larger have 60Hz & 50Hz data included on
the nameplate. Super-E® explosion proof motors have NEMA Premium® efficiency
and 3 year warranty. Fixed speed sine wave operation only. No Drip Cover.
Severe Duty
Motors
Hp
RPM
NEMA
Frame
1/3
1800
3600
1800
1800
3600
1800
3600
1800
3600
1800
3600
1800
1800
56C
56C
56C
56C
56C
56C
143TC
184C
143TC
182TC
184TC
215C
215C
CL5001A
CL5003A
CL5004A
CL5007A
CL5009A
CL5023A
CL5030T
CL5013
CL5031T
CL5027T
CL5028T
CL5018
CL5020
➁
➁
➁
➁
➁
➀
➁
➁
➁
➀
➀
➀
➀
1800
3600
1800
1200
3600
1800
1200
3600
1800
3600
1800
3600
1800
1800
56C
56C
56C
56C
56C
56C
56C
56C
56C
56C
56C
56C
56C
184C
VL5000A
VL4005A
VL5001A
VL5002A
VL5003A
VL5004A
VL5005A
VL5006A
VL5007A
VL5009A
VL5023A
VL5030
VL5024A
VL5027
➁
➁
➁
➁
➁
➁
➁
➁
➁
➁
➀
➁
➀
➀
3600
1800
3600
1800
3600
56C
56C
56C
56C
56C
56C
143TC
143TC
56C
145TC
CM7005A
CM7006A
CM7009A
CM7010A
CM7013
CM7014
CEM7014T
CEM7018T
CM7034
CEM7034T
➁
➁
➁
➁
➁
➁
➁
➁
➁
➁
1/2
3/4
1
1 1/2
Large AC
Motors
2
3
5
Washdown Duty
Motors
1/4
1/3
1/2
Explosion Proof
Motors
3/4
1
1 1/2
Pump Motors
2
1/2
3/4
HVAC Motors
1
1800
3600
1 1/2
1800
Catalog
Number
XP
Temp
Cls/Grp Code
List
Price
Mult.
Sym.
“C”
Dim.
Aprx. Full Load
Wt. (lb) Efficiency
Single Phase, C-Face, Foot Mounted
T3C
827
K
13.22
T3C
726
K
13.22
T3C
828
K
14.22
T4
924
K
15.17
T4
824
K
15.17
T2C
1,049
K
15.17
T3C
1,291
L1
15.23
T3C
2,095
L1
16.93
T3C
1,476
L1
16.10
T2C
2,162
L1
18.86
T2C
2,187
L1
18.86
T2C
3,355
L1
19.56
T2C
4,271
L1
20.69
Single Phase, C-Face, Footless
T3C
732
K
13.22
T3C
557
K
13.22
T3C
748
K
13.22
T4
1,002
K
14.30
T3C
721
K
13.22
T3C
826
K
14.22
T4
1,149
K
15.17
T4
771
K
14.30
T4
920
K
15.17
T4
826
K
15.17
T2C
1,045
K
15.17
T3C
1,189
K
15.17
T2C
1,379
K
17.42
T2C
2,194
L1
18.43
Three Phase, C-Face, Foot Mounted
T3C
867
K
13.22
T3C
938
K
13.22
T3C
895
K
13.22
T3C
956
K
14.22
T3C
936
K
13.22
T3C
1,020
K
14.30
T3C
1,342
L1
14.36
T3C
1,328
L1
14.36
T3C
1,087
K
14.30
T3C
1,453
L1
15.23
Voltage
Full Load
Notes (a)
Amps
30
35
36
49
50
49
53
83
60
99
100
154
170
60
57
64
66
66
67
70
70
74
75
76
79
84
115/208-230
115/230
115/208-230
115/230
115/230
115/230
115/208-230
115/230
115/208-230
115/230
115/230
115/230
230
3
3.7
3.7
5.3
6
6.5
7.5
9.5
11.5
11
14.5
15
21
-
29
34
34
42
28
37
51
40
48
48
52
51
76
90
62
57
60
54
57
64
59
62
66
66
67
70
75
75
115/208-230
115/230
115/208-230
115/230
115/230
115/208-230
115/230
115/230
115/230
115/230
115/230
115/208-230
115/230
115/208-230
2.1
3.5
3
3.4
3.7
3.7
4
4.9
5.3
6
6.5
7.5
8
11
-
27
30
29
34
31
40
45
45
45
52
68
74
75
73
75.5
75.5
85.5
84
81.5
86.5
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460
230/460
230/460
208-230/460
230/460
1.1
1
1.3
1.5
1.8
1.8
1.5
1.9
2.3
2.2
19
19, 30
19
19
19, 30
(a) See notes on inside back flap.
➀ = Class I, Group D; ➁ = Class I, Group D, Class II, Group F & G
Farm Duty
Motors
­78
Caution: Explosion-proof motors have a tight fit between mating parts to ensure the integrity of the explosion-proof enclosure. This can lead to an accumulation of
moisture inside the motors due to condensation. Care should be used when selecting an explosion-proof motor, especially when installed outdoors and on intermittent
duty. Consider explosion-proof motors on pages 81-86 for outdoor applications. These explosion-proof motors are not suitable for use with adjustable speed drives,
inverter duty explosion-proof motors must be used. See pages 88-90.
Single and Three Phase, C-Face
15
20
25
30
40
50
1/4
1/3
1/2
3/4
1
1800
1800
3600
1800
1200
3600
1800
1200
3600
1800
1200
3600
1 1/2
1800
1200
3600
2
3
5
7 1/2
10
1800
3600
1800
3600
1800
3600
1800
1800
VM7001A
VM7002A
VM7005A
VM7006A
VM7007A
VM7009A
VM7010A
VM7031A
VM7013
VM7014
VM7014T
VM7032
VM7018T
VM7034
VM7034T
VM7035T
VM7071T
VM7037
VM7037T
VM7075T
VM7026T
VM7042T
VM7072T
VM7044T
VM7073T
VM7045T
VM7047T
VM7170T
➁
➁
➁
➁
➁
➁
➁
➁
➁
➁
➁
➀
➁
➁
➁
➀
➁
➁
➁
➀
➁
➁
➁
➁
➀
➁
➁
➁
Voltage
Full Load
Notes (a)
Amps
53
49
56
61
97
101
119
124
166
161
235
249
357
376
369
376
512
647
552
699
746
85.5
82.5
86.5
86.5
89.5
88.5
89.5
89.5
89.5
91.7
90.2
91.7
91
92.4
91
93
91.7
93.6
93.6
94.1
94.5
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
2.4
3
2.9
3.6
4.2
5.9
6.7
8.4
9
9.4
11.8
12.2
17.5
18
23
24
28.5
30.5
36
48
58
19, 30
19, 30
19, 30
30
19, 30
19, 30
19, 30
30
19, 30
19, 30
19
19
19, 20, 30
19, 30
19, 20
19, 30
19, 20
19, 30
19, 20, 30
19
19
25
27
26
29
39
28
33
47
30
40
39
44
45
44
46
72
52
49
50
58
80
91
108
103
110
165
157
173
63
67
68
74
70
75
73
77
75.5
75.5
82.5
78.5
82.5
81.5
84
85.5
84
82.5
84
85.5
85.5
87.5
87.5
87.5
88.5
88.5
89.5
89.5
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460
230/460
230/460
230/460
208-230/460
230/460
208-230/460
230/460
230/460
230/460
208-230/460
208-230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
0.7
0.8
1.1
1
1.2
1.3
1.5
1.4
1.8
1.8
1.6
1.9
2.1
2.3
2.4
2.7
2.6
3
3.1
3.7
3.7
4.2
5.6
6.8
8.7
9.5
10.1
13
19
19, 30
19
19
19, 30
19, 30
19
19
19, 20
19, 30
19, 30
30
19, 30
19
19
(a) See notes on inside back flap.
➀ = Class I, Group D; ➁ = Class I, Group D, Class II, Group F & G
■ Cast Iron Frame
Caution: Explosion-proof motors have a tight fit between mating parts to ensure the integrity of the explosion-proof enclosure. This can lead to an accumulation of
moisture inside the motors due to condensation. Care should be used when selecting an explosion-proof motor, especially when installed outdoors and on intermittent
duty. Consider explosion-proof motors on pages 81-86 for outdoor applications. These explosion-proof motors are not suitable for use with adjustable speed drives,
inverter duty explosion-proof motors must be used. See pages 88-90.
Single Phase
Motors
56C
56C
56C
56C
56C
56C
56C
56C
56C
56C
143TC
56C
143TC
56C
145TC
145TC
145TC
56C
145TC
143TC
182TC
182TC
184TC
184TC
184TC
213TC
213TC
215TC
T3C
1,325
L1
15.23
T3C
1,177
K
15.17
T3C
1,539
L1
16.10
T3C
1,643
L1
16.10
T3C
1,866
L1
18.86
T3C
2,167
L1
18.86
T3C
2,256
L1
19.55
T2C
2,544
L1
20.36
T3C
2,887
L1
20.33
T3C
2,646
L1
21.08
T3C
3,151
L1
20.65
T3C
3,219
L1
20.65
T3C
3,419
L1
26.00
T3C
5,324
L1
26.00
T3C
5,458
L1
26.00
T3C
6,310
L1
26.00
T3C
7,197
L1
27.24
T3C
7,727
L1
28.61
T3C
8,967
L1
28.61
T3C
11,961
L1
32.00
T3C
13,601
L1
32.00
Three Phase, C-Face, Footless
T3C
871
K
13.22
T3C
890
K
13.22
T3C
861
K
13.22
T3C
936
K
13.22
T4
1,089
K
14.30
T3C
890
K
13.22
T3C
953
K
14.22
T4
1,144
K
15.17
T3C
927
K
13.22
T3C
1,001
K
15.22
T3C
1,080
L1
14.33
T2C
1,205
K
14.30
T3C
1,138
L1
14.33
T3C
1,078
K
14.30
T3C
1,164
L1
15.21
T2C
1,331
L1
17.48
T3C
1,273
L1
15.21
T3C
1,165
K
15.17
T3C
1,259
L1
15.21
T2C
1,412
L1
16.10
T3C
1,489
L1
17.49
T3C
1,614
L1
18.86
T3C
1,883
L1
18.06
T3C
1,966
L1
18.06
T2C
2,126
L1
20.36
T3C
2,475
L1
19.19
T3C
2,275
L1
19.19
T3C
2760
L1
20.65
Aprx. Full Load
Wt. (lb) Efficiency
General Purpose
Industrial Motors
1800
3600
1800
3600
1800
3600
1800
3600
1800
1800
1800
1800
➁
➁
➁
➀
➁
➁
➁
➀
➁
➁
➁
➁
➁
➁
➁
➁
➁
➁
➁
➁
➁
“C”
Dim.
Severe Duty
Motors
10
3600
CEM7071T
CM7037
CEM7037T
CEM7075T
CEM7042T
CEM7072T
CEM7044T
CEM7073T
CEM7045T
CEM7047T
CEM7174T
CEM7170T
CEM7053T
CEM7054T
CEM7059T
CEM7056T
CEM7063T
CEM7058T
CEM7060T
CEM7062T
CEM7064T
Mult.
Sym.
Large AC
Motors
7 1/2
145TC
56C
145TC
145TC
182TC
184TC
184TC
184TC
213TC
213TC
215TC
215TC
254TC
254TC
256TC
256TC
284TSC
284TC
286TC
324TC
326TC
List
Price
Washdown Duty
Motors
5
3600
1800
3600
1800
XP
Temp
Cls/Grp Code
Explosion Proof
Motors
3
1800
Catalog
Number
Pump Motors
3600
2
NEMA
Frame
HVAC Motors
RPM
Farm Duty
Motors
Hp
General
Information
Explosion Proof Motors
­79
Download