3/7/22, 2:17 PM Midterm Examination: ME 530-ME42S22 - Design of Building Piping System and Air Conditioning Duct Works Midterm Examination Due Mar 7 at 11:59pm Points 80 Questions 24 Available Mar 7 at 8:30am - Mar 7 at 11:59pm about 15 hours Time Limit 120 Minutes Allowed Attempts 2 Instructions Directions: Choose the best answer in Multiple Choices and Insert the correct numerical answer in the Numerical Answer Question. The Midterm Examination has two attempts and 120 mins per attempt. Good Luck! Attempt History Attempt Time Score KEPT Attempt 2 8 minutes 80 out of 80 LATEST Attempt 2 8 minutes 80 out of 80 Attempt 1 32 minutes 78 out of 80 Score for this attempt: 80 out of 80 Submitted Mar 7 at 2:17pm This attempt took 8 minutes. Question 1 https://tip.instructure.com/courses/29147/quizzes/383967 2 / 2 pts 1/16 3/7/22, 2:17 PM Midterm Examination: ME 530-ME42S22 - Design of Building Piping System and Air Conditioning Duct Works The opposite of a trim compressor, a base compressor is expected to be mostly loaded. If the compressed air system has only one compressor, the requirements of the Energy Standards require that the single compressor be treated as a trim compressor. Correct! Base compressor Trim compressor Online compressors Back-up compressors Question 2 2 / 2 pts An NFPA code where contains Recommended Practice for Fire Department Operations in Properties Protected by Sprinkler and Standpipe Systems NFPA 13R NFPA 13 NFPA 13D Correct! NFPA 13E https://tip.instructure.com/courses/29147/quizzes/383967 2/16 3/7/22, 2:17 PM Midterm Examination: ME 530-ME42S22 - Design of Building Piping System and Air Conditioning Duct Works Question 3 2 / 2 pts Foam extinguishing systems are effective for rapidly controlling and extinguishing flammable liquid fires. Gaseous Fire Suppression Systems Dry Chemical Fire Suppression Systems Correct! Foam Fire Suppression Systems Special Hazard Fire Protection Systems Question 4 2 / 2 pts A system that delivers mechanical energy (Pneumatic System), process air supply (mixing, agitation), drying and cleaning. Fire Protection System https://tip.instructure.com/courses/29147/quizzes/383967 3/16 3/7/22, 2:17 PM Midterm Examination: ME 530-ME42S22 - Design of Building Piping System and Air Conditioning Duct Works Compressor Pipes Correct! Compressed Air Piping System Question 5 2 / 2 pts ACFM stands for? Correct! ACTUAL MEASUREMENT OF COMPRESSED AIR EQUIVALENT TO FREE AIR AT 0 PSIG EQUIVALENT TO FREE AIR AT 10 PSIG ACTUAL CUBIC FOOT PER MINUTE Question 6 https://tip.instructure.com/courses/29147/quizzes/383967 2 / 2 pts 4/16 3/7/22, 2:17 PM Midterm Examination: ME 530-ME42S22 - Design of Building Piping System and Air Conditioning Duct Works Demand for water by a plumbing fixture varies according to its type and the occupancy category of the building in which it is installed. Fixture Unit Minimum supply pressure Drainage Fixture Units Correct! Supply Fixture Units Question 7 2 / 2 pts A compressor that is designated for part-load operation, handling the short term variable trim load of end uses, in addition to the fully loaded base compressor Back-up compressors Correct! Trim compressor Base compressor https://tip.instructure.com/courses/29147/quizzes/383967 5/16 3/7/22, 2:17 PM Midterm Examination: ME 530-ME42S22 - Design of Building Piping System and Air Conditioning Duct Works Online compressors Question 8 2 / 2 pts An NFPA code where contains Standard for the Installation of Sprinkler Systems. NFPA 11 Correct! NFPA 13 NFPA 12 NFPA 10 Question 9 2 / 2 pts It is the most economic for throttling flow and it can be hand controlled. Correct! Globe Valve https://tip.instructure.com/courses/29147/quizzes/383967 6/16 3/7/22, 2:17 PM Midterm Examination: ME 530-ME42S22 - Design of Building Piping System and Air Conditioning Duct Works Butterfly Valve Check Valve Valve Question 10 2 / 2 pts A design factor that represents a probable flowrate of a plumbing fixture. The number of fixture units depends on the volume of water required, the average duration of a single-use, and the number of uses per unit time. Correct! Fixture Unit Minimum supply pressure Drainage Fixture Units Supply Fixture Units Question 11 https://tip.instructure.com/courses/29147/quizzes/383967 2 / 2 pts 7/16 3/7/22, 2:17 PM Midterm Examination: ME 530-ME42S22 - Design of Building Piping System and Air Conditioning Duct Works Accessories in piping where the functions are to block the flow, throttle, and prevent flow reversal. Correct! Valve Check Valve Globe Valve Butterfly Valve Question 12 2 / 2 pts SCFM stands for? EQUIVALENT TO FREE AIR AT 10 PSIG Correct! EQUIVALENT TO FREE AIR AT 0 PSIG EQUIVALENT TO FREE AIR AT 14.7 PSIG ACTUAL MEASUREMENT OF COMPRESSED AIR https://tip.instructure.com/courses/29147/quizzes/383967 8/16 3/7/22, 2:17 PM Midterm Examination: ME 530-ME42S22 - Design of Building Piping System and Air Conditioning Duct Works Question 13 2 / 2 pts Designed to detect and extinguish fires in locations where standard suppression systems are not appropriate or adequate. Gaseous Fire Suppression Systems Correct! Special Hazard Fire Protection Systems Foam Fire Suppression Systems Dry Chemical Fire Suppression Systems Question 14 2 / 2 pts It prevents flow reversal and does not completely shut off reverse flow. Valve Butterfly Valve Globe Valve https://tip.instructure.com/courses/29147/quizzes/383967 9/16 3/7/22, 2:17 PM Correct! Midterm Examination: ME 530-ME42S22 - Design of Building Piping System and Air Conditioning Duct Works Check valve Question 15 2 / 2 pts All compressors that are available to serve peak load. Back-up compressors Correct! Online compressors Trim compressor Base compressor Question 16 2 / 2 pts An NFPA code where contains Standard for the Installation of Standpipe and Hose Systems. NFPA 12 https://tip.instructure.com/courses/29147/quizzes/383967 10/16 3/7/22, 2:17 PM Midterm Examination: ME 530-ME42S22 - Design of Building Piping System and Air Conditioning Duct Works NFPA 11 Correct! NFPA 14 NFPA 13 Question 17 2 / 2 pts Those compressors are not used to meet peak compressed air flow loads. It can be physically connected to the compressed air piping system and can be automatically controlled to turn on if one of the other compressors on the system fails. It does not normally operate. Base compressor Correct! Back-up compressors Online compressor Trim compressor Question 18 https://tip.instructure.com/courses/29147/quizzes/383967 2 / 2 pts 11/16 3/7/22, 2:17 PM Midterm Examination: ME 530-ME42S22 - Design of Building Piping System and Air Conditioning Duct Works Can extinguish a fire before it becomes detectable to the eye, thus protecting resources from damage and businesses from any major interruptions. Gaseous Fire Suppression Systems Special Hazard Fire Protection Systems Correct! Dry Chemical Fire Suppression Systems Foam Fire Suppression Systems Question 19 2 / 2 pts An important component of a building’s safety plan, regardless of whether it’s a commercial facility, hospital, or educational facility. Correct! fire protection system Elevator system Safety Plan System Building Plan System https://tip.instructure.com/courses/29147/quizzes/383967 12/16 3/7/22, 2:17 PM Midterm Examination: ME 530-ME42S22 - Design of Building Piping System and Air Conditioning Duct Works Question 20 2 / 2 pts Carbon dioxide is a clean and non-flammable gas that is commonly used as a fire-extinguishing agent for areas that are not typically occupied by people. CO2 efficiently and effectively extinguishes fires without leaving any toxic or liquid residue that might damage property or equipment. Correct! Gaseous Fire Suppression Systems Dry Chemical Fire Suppression Systems Special Hazard Fire Protection Systems Foam Fire Suppression Systems Question 21 10 / 10 pts Calculate the total head loss (ft) of the following system. https://tip.instructure.com/courses/29147/quizzes/383967 13/16 3/7/22, 2:17 PM Correct! Correct Answers Midterm Examination: ME 530-ME42S22 - Design of Building Piping System and Air Conditioning Duct Works 24.15 0 (with margin: 0) 0 (with margin: 0) Between 23.5 and 24.8 0 (with margin: 0) Question 22 10 / 10 pts 1” S40 galvanized steel pipe delivers 20 GPM of water. Calculate pressure drop per length of water flow (kPa/m) using Moody diagram. Correct! 3.55 https://tip.instructure.com/courses/29147/quizzes/383967 14/16 3/7/22, 2:17 PM Correct Answers Midterm Examination: ME 530-ME42S22 - Design of Building Piping System and Air Conditioning Duct Works 0 (with margin: 0) 0 (with margin: 0) 0 (with margin: 0) Between 3.05 and 4.05 Question 23 10 / 10 pts Given a system with 4 base compressors with capacities of 100 acfm (Compressor A), 300 acfm (Compressor B), 500 acfm (Compressor C), and 900 acfm (Compressor D), what is the Largest Net Capacity Increment? Correct! Correct Answers 300 0 (with margin: 0) 300 (with margin: 0) 0 (with margin: 0) 0 (with margin: 0) Question 24 10 / 10 pts Calculate the total pressure loss (psi) of the following system. https://tip.instructure.com/courses/29147/quizzes/383967 15/16 3/7/22, 2:17 PM Correct! Correct Answers Midterm Examination: ME 530-ME42S22 - Design of Building Piping System and Air Conditioning Duct Works 10.47 0 (with margin: 0) 0 (with margin: 0) 0 (with margin: 0) Between 10 and 11 Quiz Score: 80 out of 80 https://tip.instructure.com/courses/29147/quizzes/383967 16/16