EQUIPMENT SCHEDULE
PHASE 1
LOWER GROUND FLOOR (SPLIT TYPE-FCU-FAN COIL UNIT)
ITEM
NO
QTY.
UNIT DESIG.
1
1
FLGF-1
2
2
FLGF-2 & FLGF-3
3
2
FLGF-4 & FLGF-5
AREA
SERVED
PRIVATE
LECTURE ROOM
PUBLIC HEALTH
& TRAINING ROOM
PUBLIC HEALTH
& TRAINING ROOM
NOMINAL CAPACITY
TR HP
BTU/HR
AIR FLOW RATE
CFM
CMH
FAN DATA
OPERATING WT. SOUND LEVEL
WATT VOLT PHASE CYCLE
KGS.
DBA
FLOOR
LEVEL
TYPE
LGF
CEILING SUSPENDED
3.0
4.0
36,000
847
1,439
SIROCCO FAN
150
230
1
60
38
42
LGF
CEILING SUSPENDED
2.0
2.5
24,000
600
1,020
SIROCCO FAN
117
230
1
60
32
38
LGF
CEILING SUSPENDED
2.0
2.5
24,000
600
1,020
SIROCCO FAN
117
230
1
60
32
38
TYPE
REMARKS
UNIT SHALL BE INVERTER PACKAGE AIR C0NDITIOINING TYPE (CEILING SUSPENDED) COMPLETE
WITH STANDARD ACCESSORIES
UNIT SHALL BE INVERTER PACKAGE AIR C0NDITIOINING TYPE (CEILING SUSPENDED) COMPLETE
WITH STANDARD ACCESSORIES.
UNIT SHALL BE INVERTER PACKAGE AIR C0NDITIOINING TYPE (CEILING SUSPENDED) COMPLETE
WITH STANDARD ACCESSORIES.
LOWER GROUND FLOOR (SPLIT TYPE-ACCU-AIR COOLED CONDENSING UNIT)
ITEM
NO
QTY.
UNIT DESIG.
1
1
ALGF-1
2
2
ALGF-2 & ALGF-3
3
2
ALGF-4 & ALGF-5
AREA
SERVED
PRIVATE
LECTURE ROOM
PUBLIC HEALTH
& TRAINING ROOM
PUBLIC HEALTH
& TRAINING ROOM
NOMINAL CAPACITY
TR HP BTU/HR
3.0
4.0
36,000
2.0
2.5
24,000
2.0
2.5
24,000
COMPRESSOR DATA
TYPE
KW
HERMETICALLY SEALED
SWING TYPE
HERMETICALLY SEALED
SWING TYPE
HERMETICALLY SEALED
SWING TYPE
FAN DATA
TYPE
WATT
CMH
ELECTRICAL CHARACTERISTICS OPERATING WT. REF. PIPE SIZE MAX.PIPE LENGTH
KW
VOLT PHASE CYCLE
KGS
LIQUID GAS
METERS
2.03
PROFELLER FAN
200
3,780
3.03
230
1
60
65
9.50
15.90
50
1.76
PROFELLER FAN
60
2,700
2.37
230
1
60
43
9.50
15.90
50
1.76
PROFELLER FAN
60
2,700
2.37
230
1
60
43
9.50
15.90
50
REMARKS
1. APPROPRIATE ACCU CLEARANCES SHALL BE BY MANUFACTURER'S INSTALLATION STANDARD.
2.APPROPRIATE ACCU FOOTING / MOUNTING BASE SUPPORT SHALL BE BY MANUFACTURER'S INSTALLATION
STANDARD.
3.PROVIDE APPROPRIATE VIBRATION ISOLATOR FOR ACCU'S AND E MOTORS.
4.UNIT SHALL BE SUITABLE FOR OUTDOOR INSTALLATION C/W STD.ACCU'S.
LOWER GROUND FLOOR - (VRF)
ITEM
NO
QTY.
UNIT DESIG.
AREA
SERVED
FLOOR
LEVEL
1
2
FLGF-A1,A2
RECEPTION /
WAITING AREA
LGF
2
1
FLGF-A3
COUNSELING ROOM
LGF
3
1
FLGF-A4
COUNSELING ROOM
LGF
4
1
FLGF-A5
5
1
FLGF-A6
PHU EXAMINATION
ROOM 01
PHU EXAMINATION
ROOM 02
6
1
FLGF-A7
PHU 01
LGF
7
1
FLGF-A8
PHU 02
LGF
8
1
FLGF-A9
PHU 03
LGF
9
1
FLGF-A10
PHU 04
LGF
10
1
FLGF-A11
PHU 05
LGF
11
1
FLGF-A12
PHU 06
LGF
12
1
FLGF-A13
PHU 07
LGF
13
1
FLGF-A14
PHU 8
LGF
14
1
FLGF-A15
PHU STAFF
LOUNGE
LGF
15
1
FLGF-A16
RECEPTION
LGF
16
1
FLGF-A17
17
1
FLGF-A18
18
1
FLGF-A19
19
1
FLGF-A20
PHU ADMINITRATIVE
OFFICE
MEDICAL EDUC.
GALLERY
PH MED.TREATMENT
EDUC.ROOM
PHU
LOBBY
LGF
LGF
LGF
LGF
LGF
LGF
FAN COIL UNIT
NOMINAL CAPACITY AIR FLOW RATE
UNIT TYPE
TR HP
BTU/HR
CFM
CMH
WALL
MOUNTED
WALL
MOUNTED
WALL
MOUNTED
WALL
MOUNTED
WALL
MOUNTED
WALL
MOUNTED
WALL
MOUNTED
WALL
MOUNTED
WALL
MOUNTED
WALL
MOUNTED
WALL
MOUNTED
WALL
MOUNTED
WALL
MOUNTED
CEILING
SUSPENDED
WALL
MOUNTED
CEILING
SUSPENDED
CEILING MOUNTED
CASSETTE ROUND FLOW
CEILING MOUNTED
CASSETTE ROUND FLOW
CEILING MOUNTED
CASSETTE ROUND FLOW
1.5
2
18,000
530
1020
1.0
1.5
12,000
300
510
1.0
1.5
12,000
300
510
1.0
1.5
12,000
300
510
1.0
1.5
12,000
300
510
1.0
1.5
12,000
300
510
1.0
1.5
12,000
300
510
1.0
1.5
12,000
300
510
1.0
1.5
12,000
300
510
1.0
1.5
12,000
300
510
1.0
1.5
12,000
300
510
1.0
1.5
12,000
300
510
1.0
1.5
12,000
300
510
3
4
36,000
883
1500
0.75
1
9,000
282
479
3
4
36,000
883
1500
3
4
36,000
1130
1921
3
4
36,000
1130
1921
3
4
36,000
1130
1921
FAN DATA
ACCU(VRF TYPE)
UNIT DESIG.
WATTS VOLT PHASE CYCLE
TYPE
CROSS FLOW FAN
DIRECT DRIVE
CROSS FLOW FAN
DIRECT DRIVE
CROSS FLOW FAN
DIRECT DRIVE
CROSS FLOW FAN
DIRECT DRIVE
CROSS FLOW FAN
DIRECT DRIVE
CROSS FLOW FAN
DIRECT DRIVE
CROSS FLOW FAN
DIRECT DRIVE
CROSS FLOW FAN
DIRECT DRIVE
CROSS FLOW FAN
DIRECT DRIVE
CROSS FLOW FAN
DIRECT DRIVE
CROSS FLOW FAN
DIRECT DRIVE
CROSS FLOW FAN
DIRECT DRIVE
CROSS FLOW FAN
DIRECT DRIVE
SIROCCO FAN
DIRECT DRIVE
CROSS FLOW FAN
DIRECT DRIVE
SIROCCO FAN
DIRECT DRIVE
TURBO FAN
DIRECT DRIVE
TURBO FAN
DIRECT DRIVE
TURBO FAN
DIRECT DRIVE
33
230
1
60
40
230
1
60
40
230
1
60
40
230
1
60
40
230
1
60
40
230
1
60
40
230
1
60
40
230
1
60
40
230
1
60
40
230
1
60
40
230
1
60
40
230
1
60
40
230
1
60
130
230
1
60
40
230
1
60
130
230
1
60
120
230
1
60
120
230
1
60
120
230
1
60
AIR COOLED CONDENSING UNIT
NOMINAL CAPACITY
ELEC.CHARACTERISTICS
HP
BTU/HR
KW VOLT PHASE CYCLE
40
ALGF - A
382,000
29.6
380
3
60
1. APPROPRIATE ACCU CLEARANCES SHALL BE BY MANUFACTURER'S
INSTALLATION STANDARD.
2. APPROPRIATE ACCU FOOTING/ MOUNTING BASE SUPPORT SHALL BE BY
MANUFACTURER'S INSTALLATION STANDARD. 3. PROVIDE APPROPRIATE
VIBRATION ISOLATOR FOR BLOWERS, ACCU'S, AND E. MOTORS.
4.UNIT SHALL BE SUITABLE FOR OUTDOOR INSTALLATION C/W STD.
ACC'S.
LOWER GROUND FLOOR - VENTILATION SCHEDULE
ITEM
NO
QTY.
UNIT DESIG.
AREA
SERVED
FLOOR
LEVEL
TYPE
1
7
TEF-LGF-1 TO 7
TOILET
LGF
2
2
EF-LGF-1 & 2
AS SHOWN
LGF
CEILING
CASSETTE
CEILING
CASSETTE
3
4
AC-LGF 1 TO 4
ENTRANCES
LGF
AIR CURTAIN
AIR FLOW RATE
CFM
CMH
TOTAL STATIC PRESSURE
Pa.
INCH
CONSUMPTION
WATTS
ELEC.CHARACTERISTICS
VOLT
PHASE
CYCLE
100
170
100
0.4
19
230
1
60
100
170
100
0.4
19
230
1
60
800
1360
N/A
N/A
300
230
1
60
DENTAL UNIT AIR COMPRESSOR DATA
REMARKS
UNIT SHALL BE CEILING MOUNT CASSETTE TYPE SERVED AS TOILET EXHAUST FAN,
MECHANICAL CONTRACTOR TO INSTALL WIRE AND MAKE UNIT OPERATIONAL.
UNIT SHALL BE CEILING CASSETTE TYPE SERVED AS EXHAUST FAN, MECHANICAL
CONTRACTOR TO INSTALL WIRE AND MAKE UNIT OPERATIONAL.
MECHANICAL CONTRACTOR TO INSTALL WIRE AND MAKE UNIT OPERATIONAL.
FAN SCHEDULE
ITEM
NO
QTY.
1
REMARKS
ITEM NO.
1
QTY.
5
UNIT DESIG.
AIR COMPRESSOR
AREA SERVED
DENTAL UNIT 1 TO 5
FLOOR LEVEL
UGF
DENTAL OIL-LESS
SILENT TYPE
TYPE
UNIT DESIG.
AREA
SERVED
FLOOR
LEVEL
7
OF-LGF 1 TO 7
AS SHOWN
LGF
2
12
OF-GF 1 TO 12
AS SHOWN
UGF
3
6
TF-GF1 TO 6
AS SHOWN
UGF
4
2
HF-1 TO HF-2
UHS CENTRAL HALL
2F
5
2
OF-2F 1 TO 2
VIEWING AREA
2F
TYPE
CEILING MOUNTED
ORBIT FAN
CEILING MOUNTED
ORBIT FAN
CEILING MOUNTED
TRANSFER FAN
HELI FAN
5 AEROFOIL BLADES
CEILING MOUNTED
ORBIT FAN
FAN DIAMETER
INCH
FT
AIR FLOW
CFM
CMH
MAX.
RPM
ELEC.CHARACTERISTICS
VOLT PHASE CYCLE
CONSUMPTION
HP WATTS
REMARKS
16
1.3
3,037
5162
1,410
0.10
75
230
1
60
COMPLETE WITH CEILING MOUNTED ON-OFF SWITCH.
16
1.3
3,037
5162
1,410
0.10
75
230
1
60
COMPLETE WITH CEILING MOUNTED ON-OFF SWITCH.
N/A
N/A
300
510
580
0.07
55
230
1
60
288
24
360,000
612,000
53
2
1,500
230
1
60
UNIT SHALL BE CEILING MOUNT CASSETTE TYPE SERVED AS TRANSFER FAN, MECHANICAL
CONTRACTOR TO INSTALL WIRE AND MAKE UNIT OPERATIONAL.
COMPLETE WITH CEILING MOUNTED ON-OFF SWITCH AND ACCESSORIES.
16
1.3
3,037
5162
1,410
75
230
1
60
COMPLETE WITH CEILING MOUNTED ON-OFF SWITCH.
0.10
UPPER GROUND FLOOR - BLOWERS SCHEDULE:
AIR FLOW RATE
CFM
CMH
TOTAL STATIC PRESSURE
Pa.
INCH
MOTOR DRIVE
HP
ELEC.CHARACTERISTICS
WATTS VOLT PHASE CYCLE
ITEM
NO
QTY.
UNIT DESIG.
AREA
SERVED
FLOOR
LEVEL
1
1
FAB1
GENERATOR ROOM
UGF
AXIAL BLOWER
9300
15800
250
1
3
800
380
3
60
2
1
ISO1
ISOLATION ROOM
UGF
NEGATIVE PRESSURE
ISOLATION UNIT
582
990
N/A
N/A
0.23
175
230
1
60
TYPE
CAPACITY LITER
TANK CAPACITY
LITER
SIZE
LxWxH
WT
KGS
MOTOR DRIVE
HP
ELEC.
CHARACTERISTICS
REMARKS
UNIT SHALL BE COMPLETE PACKAGE WITH COMPLETE STANDARD
ACCESSORIES.
UNIT SHALL BE COMPLETE PACKAGE WITH STANDARD ACCESSORIES.
REMARKS
165
35
410x410x600
27
1
WATTS
VOLT
PHASE
850
220
1
CYCLE
60
UNIT SHALL BE DENTAL OIL LESS AIR
COMPRESSOR SILENT TYPE 1HP
APPROVED OR EQUAL WITH COMPLETE
STANDARD ACCESSORIES.
EQUIPMENT SCHEDULE