EQ setting for Beyerdynamic DT770 (fresh earpads)
SPL Frequency Response
with EQ
30
30
20
20
Sound Pressure Level [dBr]
Sound Pressure Level [dBr]
SPL Frequency Response
without EQ
10
0
-10
10
0
-10
Harman AE/OE 2 018 Target
Raw Frequency Response
Compensated Frequency Response
-20
10
100
Harman AE/OE 2 018 Target
Raw Frequ ency Response
Compensated Freq uency Response
-20
1.000
10.000
10
100
Frequency [Hz]
EQ Curve
Individual Filters
20
f3
105 Hz
f4
210 Hz
f6
f8
f10
3800 Hz 6450 Hz
10000 Hz
10
Amplitude [dBr]
Amplitude [dBr]
10
0
-10
0
-10
f1
43 Hz
f2
90 Hz
f5
2550 Hz
f7
f9
5100 Hz8300 Hz
-20
-20
10
100
1.000
10.000
10
100
1.000
10.000
Frequency [Hz]
Frequency [Hz]
Error Curve Histogram
without EQ
100%
Error Curve Histogram
with EQ
80%
Relative Statistic Frequency [%]
80%
Relative Statistic Frequency [%]
10.000
EQ Curve
total
20
100%
1.000
Frequency [Hz]
60%
40%
20%
60%
40%
20%
less
-20
-15
-10
-9
-8
-7
-6
-5
-4
-3
-2
-1
1
2
3
4
5
6
7
8
9
10
15
20
more
0%
less
-20
-15
-10
-9
-8
-7
-6
-5
-4
-3
-2
-1
1
2
3
4
5
6
7
8
9
10
15
20
more
0%
Deviation [dB]
Deviation [dB]
Filter Settings
Filter Type Frequency
Band 1
PEAK
43 Hz
Band 2
PEAK
90 Hz
Band 3
LOW_SHELF
105 Hz
Band 4
PEAK
210 Hz
Band 5
PEAK
2550 Hz
Band 6
PEAK
3800 Hz
Band 7
PEAK
5100 Hz
Band 8
PEAK
6450 Hz
Band 9
PEAK
8300 Hz
Band 10
HIGH_SHELF 10000 Hz
Gain
-9,5 dB
2,0 dB
5,5 dB
6,0 dB
-1,6 dB
3,0 dB
-2,8 dB
-4,0 dB
-3,9 dB
-4,0 dB
Q-Factor
0,25
1,4
0,71
1,3
2,0
1,0
3,0
4,0
4,0
0,71
BW
4,17
1,01
1,08
0,71
1,39
0,48
0,36
0,36
Preamp gain:
-2,6 dB
Deviation from Target
Before EQ After EQ
1,69 dB
0,82 dB
Use this settings if your earpads are <1 year old
Adjust gain of band 3 to preference (bass)
Adjust gain of band 6 to preference (presence)
Adjust gain of band 10 to preference (airiness)
Preference Rating*
Before EQ After EQ
83/100
92/100
*preference rating prediction based on:
[1] S. Olive et al: "A Statistical Model That Predicts Listeners' Preference Ratings of In-Ear Headphones: Part 1" (2017)
[2] S. Olive et al: "A Statistical Model That Predicts Listeners' Preference Ratings of In-Ear Headphones: Part 2" (2017)
[3] S. Olive et al: "A Statistical Model That Predicts Listeners' Preference Ratings of Around-Ear and On-Ear Headphones" (2018)
The normalized preference ratings are used, where zero deviation from target equals a preference rating of 100
measured on GRAS45BC KEMAR
GRAS KB5000/5001 anthropometric pinnae
APx515 or APx526 Signal Generator/Analyzer
APx1701 amplifier
v2.9
by oratory1990
14.04.21
Download