User manual Barkey XPT heating system Version 5 GB Issue 2013-10-23 Barkey autocontrol 3XPT Barkey autoline XPT 4R Barkey autotherm XPT Manufactured by: Barkey GmbH & Co. KG Gewerbestrasse 8 33818 Leopoldshoehe Germany User manual Barkey XPT heating system Contents Table of Contents 1 2 Introduction ................................................................................................. 1 1.1 Important things to observe ..................................................................... 1 1.2 Pictograms, signal words and symbols .................................................. 2 1.3 Target group.............................................................................................. 2 1.4 Disclaimer of liability ................................................................................ 2 1.5 Copyright ................................................................................................... 3 1.6 Conformities.............................................................................................. 3 1.7 Further development ................................................................................ 3 Barkey autocontrol 3XPT ........................................................................... 4 2.1 Overtemperature protection..................................................................... 5 2.2 Contra-indications .................................................................................... 5 2.3 Safety features .......................................................................................... 5 2.4 Intended purpose / Use for the intended purpose .................................. 6 2.5 2.5.1 2.5.2 2.5.3 Safety instructions.................................................................................... 7 Safety instructions for using the device ....................................................... 7 Safety instructions on handling the device .................................................. 9 Safety instructions and environmental influences...................................... 10 2.6 2.6.1 2.6.2 2.6.3 Electromagnetic properties / safety distances ..................................... 11 Electromagnetic outputs ........................................................................... 11 Electromagnetic immunity ......................................................................... 12 Recommended safety distance ................................................................. 14 2.7 2.7.1 2.7.2 2.7.3 2.7.4 2.7.5 Controls and displays ............................................................................ 15 Operating panel ........................................................................................ 15 Symbols on labels ..................................................................................... 16 Safety instructions sticker for Barkey autoline XPT 4R heater ................... 17 Connection area ....................................................................................... 18 Stand clamp.............................................................................................. 18 2.8 Operation................................................................................................. 20 2.8.1 Getting started .......................................................................................... 20 2.8.1.1 Installation location ............................................................................... 20 2.8.1.2 Installing the device .............................................................................. 21 2.8.1.3 Connecting the power cord................................................................... 21 2.8.1.4 Connecting the heaters ........................................................................ 22 2.8.1.5 Connecting an optional temperature measurement sensor................... 23 2.8.1.6 Switching on ......................................................................................... 23 2.8.1.7 Login screen......................................................................................... 24 2.8.1.8 Main screen.......................................................................................... 24 2.8.1.9 Switching off ......................................................................................... 25 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Contents 2.8.2 Calling up the devices functions that are displayed as menu items ........... 25 2.8.2.1 Menu overview ..................................................................................... 25 2.8.2.2 Calling up the menu ............................................................................. 26 2.8.2.3 "Temperature measurement" device function ....................................... 27 2.8.2.4 "Set value channel 1" and "Set value channel 2" device functions ........ 29 2.8.2.5 "Overnight mode" device function ......................................................... 31 2.8.2.6 "Language selection" device function ................................................... 32 2.8.2.7 "Information System" device function ................................................... 33 2.8.2.8 "Channel 1 information" and "Channel 2 information" device functions . 34 3 Barkey autoline XPT 4R ........................................................................... 36 3.1 Device functions ..................................................................................... 37 3.2 Safety features ........................................................................................ 37 3.3 Intended purpose / Use for the intended purpose ................................ 38 3.4 3.4.1 3.4.2 3.4.3 Safety instructions.................................................................................. 39 Safety instructions for using the device ..................................................... 39 Safety instructions on handling the device ................................................ 41 Safety instructions and environmental influences ...................................... 42 3.5 Components of the heater ...................................................................... 43 3.5.1 Wärmeprofil mit Steuerleitung ................................................................... 43 3.5.2 Support with stand clamp .......................................................................... 44 3.6 3.6.1 3.6.2 3.6.3 3.6.4 4 Getting started ........................................................................................ 44 Installation location ................................................................................... 44 Installing the heater................................................................................... 45 Inserting the infusion tube ......................................................................... 46 Connecting the heater ............................................................................... 47 Barkey autotherm XPT ............................................................................. 49 4.1 Device functions ..................................................................................... 50 4.2 Safety features ........................................................................................ 50 4.3 Intended purpose / Use for the intended purpose ................................ 51 4.4 4.4.1 4.4.2 4.4.3 Safety instructions.................................................................................. 52 Safety instructions for using the device ..................................................... 52 Safety instructions on handling the device ................................................ 54 Safety instructions and environmental influences ...................................... 55 4.5 Components of the heater ...................................................................... 56 4.6 4.6.1 4.6.2 4.6.3 4.6.4 Getting started ........................................................................................ 57 Installation location ................................................................................... 57 Installing the heater................................................................................... 58 Application ................................................................................................ 58 Connecting the heater ............................................................................... 59 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Contents 5 Cleaning and care ..................................................................................... 61 6 Maintenance .............................................................................................. 62 7 6.1 Technical safety inspection (TSI) .......................................................... 62 6.2 Replacing the battery ............................................................................. 63 Error messages......................................................................................... 64 7.1 Barkey autocontrol 3XPT error codes ................................................... 65 7.2 Error codes for heater channel 1 ........................................................... 66 7.3 Error codes for heater channel 2 ........................................................... 66 8 Warranty and disclaimer .......................................................................... 67 9 Customer Service ..................................................................................... 68 10 Factory settings for temperature............................................................. 69 11 Specifications ........................................................................................... 70 11.1 Barkey autocontrol 3XPT ....................................................................... 70 11.2 Barkey autoline XPT 4R .......................................................................... 71 11.3 Barkey autotherm XPT ........................................................................... 72 Device master data sheet template Declaration of Conformity Certificates User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Introduction 1 Introduction This user manual is intended as an introduction to the commissioning, use and maintenance of the following devices: 1.1 Barkey autocontrol 3XPT control unit Barkey autoline XPT 4R heater profile Barkey autotherm XPT heater jacket Important things to observe WARNING Carefully read through this user manual before using the device. Comply strictly with the instructions for correct use and the safety instructions contained in this user manual. For a better understanding of these chapters you should familiarise yourself with the basic functions of the device as described at the start of Chapters 0 to 4. You should also comply with the requirements for the training and skills of persons using the device, as indicated in Chapter 1.3. WARNING Medical electrical devices are subject to particular precautionary measures with regard to EMC (electromagnetic compatibility). Make sure that the devices are installed and commissioned in accordance with the EMC advice contained in this user manual. You must follow the conditions of use and safety instructions contained in this user manual at all times when using the devices. This will ensure that the devices are handled properly and that patients and users cannot be put at risk nor equipment damaged. Barkey GmbH & Co. KG can accept no liability for damage caused as a result of failure to follow this user manual. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 1 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system 1.2 Introduction Pictograms, signal words and symbols These instructions use the following pictograms and symbol words to highlight warnings and special advice: WARNING If not observed: danger to people. CAUTION If not observed: Gefahr for Sachen, das Gerät oder elementare Gerätefunktionen. NOTE Additional helpful advice and information. (The "i" stands for "information".) You will find the following symbol in instructions about the use and maintenance of the device: Step contained in instructions. Carry out this step as indicated. ► NOTE The symbols that are associated with the controls and indicators on the devices, and the symbols on the stickers on the devices are explained in Chapter 0 of this user manual. 1.3 Target group This user manual is intended for use by: medical specialists in hospitals who hold a recognised vocational qualification in medicine, and specialist medical technicians who hold an accepted vocational qualification as an electrical device electronics engineer or equivalent training WARNING Only personnel who meet these requirements may use and service the devices. 1.4 Disclaimer of liability The manufacturer and/or its subsidiary companies can accept liability for the safety, reliability and performance of the systems only provided that all operating procedures, adjustments and repairs are carried out by properly trained and qualified personnel; provided that all modifications to the device are authorised in writing by the manufacturer carried out by properly trained and qualified personnel; provided that the electrical installation of the treatment room complies with local regulations and IEC requirements (where they apply); and provided that the devices are used according to the published user manuals (these documents). 2 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de Introduction 1.5 User manual Barkey XPT heating system Copyright This user manual and all illustrations it contains are protected by copyright. Translation, duplication, reprinting, extraction of images, reproduction using photographic technology and storage and processing in electronic systems, even only as excerpts, or any alterations shall require the written authorisation of Barkey GmbH & Co. KG. Any further usage which goes beyond using the contents described in connection with the product purchased is not permitted. Third party products, protected trademarks etc. are stated without reference to the registration or copyright status as a matter of principle. Existing industrial property rights and registered trademarks are explicitly acknowledged. We reserve the right to make corrections of typographical errors and mistakes and to make changes in the interests of technical progress or which are necessary due to changes in regulations. 1.6 Conformities Full particulars regarding conformity can be found in the attached declaration of conformity. 1.7 Further development The devices in the Barkey XPT heating system are the result of continuing development team work between scientists, technical experts, users and Barkey GmbH & Co. KG. Barkey GmbH & Co. KG is continuing to make further developments and add new features to the XPT product line and will ensure compatibility between the Barkey autocontrol 3XPT control unit and the Barkey XPT heaters. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 3 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system 2 Barkey autocontrol 3XPT Barkey autocontrol 3XPT Figure 1: Barkey autocontrol 3XPT The Barkey autocontrol 3XPT control unit is capable of controlling up two Barkey XPT heaters to the pre-set value at the same time. Depending on the heater that is connected, the set value for each heater can be set within the range +33 °C to +43 °C for each heater. The Barkey autocontrol 3XPT detects various different heaters as they are connected and automatically performs the settings for the relevant control requirements. The display shows the current temperature of the heater. Two connection sockets are provided on the front of the Barkey autocontrol 3XPT control unit for connection of the heater profiles. Access using the serial interface on the underside of the device is reserved for communications devices approved by the manufacturer. An ambient temperature sensor or a sensor for measuring temperatures can be connected to the connection for an external sensor. WARNING External temperature sensors sold by Barkey are not medical electrical thermometers and therefore must not be used for medical measurements (such as the patient's temperature). The Barkey autocontrol 3XPT is controlled by means of a operating panel which is equipped with buttons, a large display and indicator lamps. In addition the device is equipped with an acoustic buzzer which serves to draw attention to any faults that occur. The Barkey autocontrol 3XPT is equipped with a mounting lug on the back. This allows it to be mounted on either an infusion stand or a standard rail. The back wall of the device is shaped at the top into a grip recess, so that the user can safely carry and manipulate the device by hand. 4 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de Barkey autocontrol 3XPT 2.1 User manual Barkey XPT heating system Overtemperature protection The Barkey autocontrol 3XPT control unit is equipped with a separate overtemperature protection for each channel. This operates by reference to the set value. This overtemperature protection value is defined as 1°C above the respective set value for the heater that is connected. After the device has been switched on or after connection of a heater this overtemperature protection is at first set to the maximum value so as to avoid false alarms if the heaters had previously been heated. As soon as the actual temperature falls below the set value, overtemperature protection is automatically initiated at a value 1°C above the set value. Each heater incorporates a second overtemperature protection which is factory-set to a value specific to the type of heater. This second overtemperature protection monitors the temperature in the heater via a separate measurement sensor. The overtemperature protection cutout function is implemented within the control unit as an independent circuit. At soon as the temperature of one of the heaters reaches one of the two overtemperature protection values, both channels are switched off automatically and the connected heaters start to cool down. The fault indication lights up and an acoustic signal sounds. An error message is shown in the display. The error messages are identified by numeric codes, which are listed in Chapter 7. 2.2 Contra-indications There are no known contra-indications in relation to heating and keeping warm transfusions, infusions and fluids (purging solutions), for the avoidance of hypothermia. 2.3 Safety features Safe control of the heating conditions at the connected heaters by permanently pre-set temperature bands restricted to a safe range and by dual-band overtemperature protection, which permanently shuts down the device in the event of overtemperature. When the Barkey infusion heating system is used it ensures there is no degradation of important and sensitive biological components of the blood and blood products due to excessive temperatures When the Barkey patient heating system is used it ensures there is no disturbance or injury to the patient due to excessive temperatures Plain local language text displays Clearly arranged and labelled displays and controls. Device is designed for continuous operation Power supply to the heaters via a non-hazardous safety low voltage Automatic cut-out if overtemperature occurs in the power electronics Corrosion-free plastic casing Secure attachment of the device with a sturdy stand clamp User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 5 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system 2.4 Barkey autocontrol 3XPT Intended purpose / Use for the intended purpose The purpose of the Barkey autocontrol 3XPT active medical device is to act as a control unit for two active therapeutic heaters for heating and keeping warm whole blood, erythrocyte concentrates, infusion solutions and other substances and materials to + 37°C in a way that is hygienic, corresponds to patients' needs, biologically protective and safe. The Barkey autocontrol 3XPT has the following areas of application: Heating and keeping warm whole blood, blood products and plasma conserves when connected to Barkey infusion heating system heaters Continuous operation heating and keeping warm non-denaturisable infusion solutions when connected to Barkey infusion heating system heaters Protection of patients against chilling and overheating when connected to Barkey patient heating system heaters The Barkey autocontrol 3XPT be used whenever it is desirable to prevent the chilling of patients as a result of cold transfusions and infusion solutions. These summarised statements on the intended use of the device are supplemented in this user manual by specific descriptions of the various different applications and of the handling of the device. You will find these descriptions in Chapters 0 to 2.8 of this user manual. Please use these chapters to find specific information about usage of the device in individual cases. 6 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de Barkey autocontrol 3XPT 2.5 2.5.1 User manual Barkey XPT heating system Safety instructions Safety instructions for using the device The device and its system components must be checked WARNING before every use to ensure they are all intact. Damaged devices must not be used. In order not to put the safety of the patient or operator at risk, do not use the device if one of the following conditions applies: - The power cords, mains plugs, control leads, plugs or sockets are damaged or worn - The casing or operating panel is damaged - The device has been dropped or its internal electronic components have become wet - The device does not heat correctly (as displayed by optical and acoustic alarms) - The yellow alarm lamp and/or acoustic alarm (on the display) is activated - The heater is damaged. All electrical installations must comply with the relevant applicable regulations and standards, in addition to the specifications stated by the manufacturer. Before using the Barkey autocontrol 3XPT control unit, thoroughly read all the relevant chapters in this user manual, together with all chapters on the heaters that will be connected. Before using the temperature measurement sensors, read the associated user documentation. The manufacturer can accept no liability for the safety of the patient if the operating, maintenance and adjustment procedures for the system deviate from the procedures described in this user manual or in the service manual. Persons using the device must be properly trained and qualified. Only use the device in accordance with the regulations as described previously and in accordance with the processes described in this user manual. The Barkey autocontrol 3XPT control unit may be operated only in conjunction with Barkey XPT series heaters. Before the Barkey autocontrol 3XPT is used with a heater, both devices must be allowed to acclimatise at the place of use for at least an hour at ambient temperature. If heaters are connected to the Barkey infusion heating system to heat or keep warm infusion solutions or medicaments, the user must make sure that the temperature settings at the device are appropriate and that the controls are effective. If this is not so, the user must adjust the temperature settings to values appropriate to the infusion solutions or medicaments. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 7 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system WARNING 8 Barkey autocontrol 3XPT After being connected to the Barkey autocontrol 3XPT, a heater must remain connected for at least 6 seconds. Otherwise the parameters saved in the heater will not be recognised correctly. After disconnecting a heater from the Barkey autocontrol 3XPT, you must wait at least 6 seconds before connecting another heater. Otherwise the parameters saved in the heater will not be recognised correctly. The heater contains no parts which can be repaired by the user. Do not carry out repairs to the heater yourself. Please contact Barkey GmbH & Co. KG or your medical technician service, who can request information about repair from the manufacturer. Repairs and modifications to the device may only be carried out by Barkey GmbH & Co. KG or authorised personnel. The infusion system and/or patient heating system can be used at ambient temperatures from +10 °C to +40 °C and is suitable for continuous operation. If a malfunction alarm occurs during self-test, the system must not be used. Call a trained qualified service technician. If the Barkey autocontrol 3XPT is operated with accessories, these must exclusively be those approved by Barkey GmbH & Co. KG. The use of unapproved accessories can lead to increased radiated electromagnetic emissions (EMI) or reduce the device's immunity to electromagnetic interference. If the overtemperature alarm sounds, allow the temperature of the heaters to fall to a value less than the maximum permissible set temperature for the heater that is connected. Otherwise the supply of fluids to the patient must be stopped immediately or the heater disconnected from the patient. Only measurement sensors approved by Barkey GmbH & Co. KG may be connected to the external temperature measurement sensor port. These external temperature sensors are not medical thermometers and therefore they may not be used for medical purposes (such as taking the patient's temperature). The control unit must not be used if it has a fault. The control unit should be examined by Barkey GmbH & Co. KG or by an authorised person. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de Barkey autocontrol 3XPT 2.5.2 User manual Barkey XPT heating system Safety instructions on handling the device Before using the Barkey autocontrol 3XPT control unit, thoroughly read all the relevant chapters in this user manual, WARNING together with all chapters on the heaters that will be connected. Before using the temperature measurement sensors, read the associated user documentation. All electrical installations must comply with the relevant applicable regulations and standards, in addition to the specifications stated by the manufacturer. The user is responsible for correct installation. The mains plug must be removed from the mains socket to ensure safe isolation of the device from the power supply. Using cleaning products and disinfectants other than as described in this User manual can damage the device. Check with the manufacturer before using cleaning agents which are not expressly recommended for use. In particular, you are warned against the use of the following solutions: - halogenated aromatic and aliphatic solvents; - ketonic solvents. The device contains no parts which can be repaired by the user. Do not carry out repairs to the device yourself. Please contact Barkey GmbH & Co. KG or your medical technician service, who can request information about repair from the manufacturer. Repairs and modifications to the device may only be carried out by Barkey GmbH & Co. KG or authorised personnel. An annual technical safety inspection must be carried out by qualified service personnel or employees of Barkey GmbH & Co. KG. The battery (lithium battery CR 1225, 3 V) must be replaced every three years by qualified service personnel or CAUTION employees of Barkey GmbH & Co. KG. The 3XPT infusion and patient heating system must be cleaned regularly. Before cleaning the 3XPT infusion heating system it must be disconnected from the mains supply by withdrawing the power plug from the mains socket. The device rating plate can be found at the bottom of the back panel. The power supply requirements and the serial number ("SN") of the device are specified on this. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 9 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system 2.5.3 10 Barkey autocontrol 3XPT Safety instructions and environmental influences The influence of strong electromagnetic fields (e.g. through the use of HF therapy or surgical devices) can lead to malfunctions WARNING in devices of the Barkey XPT heating system. If interference of this type occurs, increase the distance between the XPT device suffering interference and the device causing the interference, or do not operate both devices at the same time. XPT devices work perfectly within the interference limit values set in the EN 60601-1-2 standard. XPT devices can be affected by interference outside the limit values set by EN 60601-1-2. The 3XPT infusion heating system may not be used immediately next to other devices or stacked on top of other devices. If it is necessary to operate the device next to or stacked on top of other devices, the 3XPT infusion heating system should be monitored to check that it is working correctly in this situation. Portable and mobile HF communication equipment such as mobile phones can affect XPT devices. Do not use XPT devices in the immediate vicinity of flammable materials (e.g. gases, liquids), flammable mixtures of anaesthetic substances with air, flammable mixtures of anaesthetic substances with oxygen or laughing gas whose flashpoint is below 50℃. In particular, it is imperative that XPT devices are not used in the same areas where alcohol disinfectants and anaesthetising substances are being used at the time. Only power supply cords supplied by Barkey GmbH & Co. KG which are designed for the rated voltage of the device may be used. The operation of accessories, converters or cabling in conjunction with devices or systems other than those listed here can lead to increased emissions or reduced device immunity. XPT devices may not be operated in the immediate vicinity of devices with a high thermal discharge output. Cables must be laid where they cannot affect the operation of any other devices. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de Barkey autocontrol 3XPT 2.6 2.6.1 User manual Barkey XPT heating system Electromagnetic properties / safety distances Electromagnetic outputs Guidelines and manufacturers declaration - Electromagnetic emission The Barkey autocontrol 3XPT is suitable for operation in any of the environments listed below. The customer or user of the Barkey autocontrol 3XPT must ensure that it is operated in one of these environments. Electromagnetic environment Radiated EMI measurements Compliance guidelines The Barkey autocontrol 3XPT uses high-frequency energy for internal functions only. This means that HF HF emissions to CISPR 11 Group 1 emission is very low, and neighbouring electronic devices are unlikely to be affected. HF emissions to CISPR 11 Class B The Barkey autocontrol 3XPT is suitable for use in buildings other Harmonic emissions to IEC 61000- Class A than residential and those which are 3-2 directly connected to a public Emission of voltage Complies supply network which is also used fluctuations/flickering to to supply buildings used for IEC 61000-3-3 residential purposes. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 11 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system 2.6.2 Barkey autocontrol 3XPT Electromagnetic immunity Guidelines and manufacturers declaration - Electromagnetic immunity The Barkey autocontrol 3XPT is intended for operation in any of the electromagnetic environments listed below. The customer or user of the Barkey autocontrol 3XPT must ensure that it is operated in one of these environments. IEC 60601 test Electromagnetic environment Immunity test Compliance level level Guideline ± 6 kV The floor should be constructed in ± 6 kV Contact wood or concrete or be covered Static discharge Contact discharge with ceramic tiles. If the floor is (ESD) to discharge covered with synthetic material, IEC 61000-4-2 ± 8 kV air the relative humidity must be at ± 8 kV air discharge discharge least 30 %. ± 2 kV for power ± 2 kV for power Rapid transient cords cords The quality of the supply voltage electrical noise/ should comply with a typical bursts to ± 1 kV for input ± 1 kV for input and business or hospital environment. IEC 61000-4-4 and output cords output cords ± 1kV voltage ± 1kV voltage phase-to-phase phase-to-phase The quality of the supply voltage Surges to IEC should comply with a typical 61000-4-5 ± 2kV Not applicable business or hospital environment. voltage phase-to- (double insulated earth class II) < 5 % UT < 5 % UT (> 95 % drop of (> 95 % drop of UT ) The quality of the supply voltage UT ) for 1/2 cycle should comply with a typical for 1/2 cycle business or hospital environment. 40 % UT 40 % UT Voltage dips, If the user of the Barkey ( 60 % drop of ( 60 % drop of UT ) short-time autocontrol 3XPT requires interruptions and UT ) for 5 cycles for 5 cycles continued operation even if the fluctuations of 70 % UT power supply is interrupted, we 70 % UT supply voltage to (30 % drop of (30 % drop of UT ) recommend that the Barkey IEC 61000-4-11 UT ) for 25 autocontrol 3XPT is connected to for 25 cycles cycles an uninterruptible power supply < 5 % UT < 5 % UT or to a battery. (> 95 % drop of (> 95 % drop of UT UT ) for 5s ) for 5s Magnetic field at 3 A/m 3 A/m Magnetic fields at mains supply frequency frequency should comply with the (50/60 Hz) in typical values as found in accordance with business and hospital IEC 61000-4-8 environments. NOTE: UT is the mains AC supply before applying the test rule 12 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Barkey autocontrol 3XPT Guidelines and manufacturers declaration - Electromagnetic immunity The Barkey autocontrol 3XPT is intended for operation in any of the electromagnetic environments listed below. The customer or user of the Barkey autocontrol 3XPT must ensure that it is operated in one of these environments. IEC 60601 Electromagnetic environment Immunity test Compliance level test level guidelines Portable and mobile radio sets should not be used within a distance from the Barkey autocontrol 3XPT including its cords that is less than the recommended safety distance as calculated by the relevant equation for the transmitted frequency. Recommended safety distance Wire-borne HF 3 Veff d = 1.17 √P 3 Veff interference to 150 kHz to 150 kHz to 80 MHz for 150 kHz to 80 MHz IEC 61000-4-6 80 MHz Radiated HF interference to IEC 61000-4-3 3 V/m 80 MHz to 2.5 GHz d = 1.17 √P 3 V/m 80 MHz to 2.5 GHz for 80 kHz to 800 MHz d = 2.33 √P for 800 MHz to 2.5 GHz where P is the nominal power of the transmitter in Watts (W) as stated by the transmitter manufacturer and d is the recommended safety distance in metres (m). An on-site investigation must show that the field strength a of stationary transmitters is less than the compliance level b at all frequencies. Interference is possible near devices that display the following symbol. NOTE 1 The higher frequency level applies at 80 MHz and 800 MHz. NOTE 2 These guidelines may not apply in all cases. The propagation of electromagnetic variables is affected by absorption and reflection of buildings, objects and people. a The field strength of stationary transmitters, such as base stations of radio telephones and mobile land radios, amateur radios, AM and FM radio and television transmissions cannot be precisely theoretically predetermined. You should consider carrying out a site study to determine the electromagnetic environment with regard to stationary transmitters. If the measured field strength at the location where the Barkey autocontrol 3XPT is being used exceeds the above compliance levels, the Barkey autocontrol 3XPT should be monitored to ensure that the device is functioning as intended. If unusual performance characteristics are observed, additional measures such as changing the alignment or location of the Barkey autocontrol 3XPT may be necessary. b The field strength should be less than 3 V/m in the frequency range 150 kHz to 80 MHz. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 13 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system 2.6.3 Barkey autocontrol 3XPT Recommended safety distance Recommended safety distances between portable and mobile HF telecommunications devices and the Barkey autocontrol 3XPT The Barkey autocontrol 3XPT is intended for operation in an electromagnetic environment in which HF interference is controlled. The customer or user of the Barkey autocontrol 3XPT can help avoid electromagnetic interference by observing the minimum distance between portable and mobile HF communications devices (transmitters) and the Barkey autocontrol 3XPT as stated below, depending on the output power of the communication device. Safety distance depending on transmitter frequency m Nominal 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2.5 GHz transmitter power W d 1.17 P d 1.17 P d 2.33 P 0.01 0.12 0.12 0.23 0.1 0.37 0.37 0.74 1 1.17 1.17 2.33 10 3.69 3.69 7.38 100 11.67 11.67 23.33 For transmitters whose maximum nominal output is not given in the above table, the recommended safety distance d in metres (m) can be calculated using the equation belonging to the appropriate column, where P is the maximum nominal output of the transmitter in Watts (W) as stated by the transmitter manufacturer. NOTE 1 The higher frequency level applies at 80 MHz and 800 MHz. NOTE 2 These guidelines may not apply in all cases. The propagation of electromagnetic variables is affected by absorption and reflection of buildings, objects and people. 14 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Barkey autocontrol 3XPT 2.7 2.7.1 Controls and displays Operating panel The Barkey autocontrol 3XPT device is provided with an operating panel on the front with a multi-line display, 4 buttons and 4 lights (LEDs). On/Off button Operation indicator Störungsanzeige Display Operation indic channel 1 (LED) Operation indic channel 2 (LED) Selection button Confirmation button Figure 2: Operating panel Button for turning the device on and off. Selection button for input in the user dialogue. Each button has its function shown in the display. Confirmation button for input in the user dialogue. Each button has its function shown in the display. The green light (LED) shows that the device has been switched on. 1 2 The two orange operation indicators (LEDs) are each assigned to a channel of the autocontrol 3XPT and indicate that a heater is connected and has been detected. The yellow light (LED) indicates a device malfunction. The display is for information about the heaters currently connected and their temperature set values and actual values, displaying the menu for operation of the device, displaying the status of the various device functions that can be called up using the menu, and outputting error messages. An acoustic signal transmitter indicates when an error has occurred. A message is additionally shown in the display in the event of errors. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 15 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system 2.7.2 Barkey autocontrol 3XPT Symbols on labels Labels showing printed symbols are affixed to the Barkey XPT heating system devices. These have the following meaning: This symbol declares that the device conforms with EU Directive 93/42/EEC of 14th June 1993 for medical devices. The four-digit number indicates the appointed body (TÜV Product Service) which supervises the manufacturer's quality assurance system. IP X1 This symbol means that the device is protected against vertically dripping water (incident angle to the vertical 0°) to IEC 601-1 in its intended operating conditions. This symbol indicates that the device with its application part is of type CF (cardio floating) and is defibrillation proof. This symbol indicates that the electrical protective insulation within the device protects the user from electric shocks and that the device does not need to be connected to the protective earth cable of the building's alternating current power supply (double insulated class II). This symbol shows the year of manufacture as a four-digit number. 2014 This symbol identifies the month and the year in which the next safety inspection must be carried out. This symbol advises you that you must comply with the user manual supplied. This symbol indicates that the mains plug must be withdrawn from the socket before the device housing is opened. This symbol indicates the humidity range which the medical device can be safely exposed to. The values limiting humidity are located next to the upper and lower horizontal line. You can find the limit values in the “Technical data” section. 16 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de Barkey autocontrol 3XPT User manual Barkey XPT heating system This hazard symbol advises you that failure to follow the instructions contained in this user manual can result in hazards to patients, the device user or the device itself. This symbol indicates that the device may not be disposed of with household waste. It must be recycled professionally or returned to the manufacturer for disposal. 2.7.3 Safety instructions sticker for Barkey autoline XPT 4R heater A label is fixed to the front of the Barkey autocontrol 3XPT unit. The symbols indicate which safety instructions must be specially complied with when using the Barkey autoline XPT 4R heater, and the ways in which the Barkey autoline XPT 4R heater may not be used. WARNING If instructions contained in this user manual are not observed, hazards can occur for patients, the device user or the device itself. Before starting to use the device, read this user manual thoroughly. Do not kink, cover, warm or cool the heater! Do not cover the heaters with cloths or dressing materials, do not run them under bedcovers, hot-air covers, etc., and do not expose them to direct sunlight or thermal radiation. Only run the heater uncovered through the air. Do not run it into or through incubators. Do not shorten or damage the heater. Figure 3: Safety instructions sticker for the Barkey autoline XPT 4R User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 17 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system 2.7.4 Barkey autocontrol 3XPT Connection area Heater connection (channel 2) Heater connection (channel 1) for special applications only for Barkey service personnel External temperature measurement sensor Ventilation grille Power cord Figure 4: Underside of the device All the connection ports of the Barkey autocontrol 3XPT and exit point of the integral power cord for the device are located in two areas on the underside of the device. This means the cables run directly downwards from the device in its correctly installed position. This prevents the formation of loops and tangles in the cables, which can contribute to accidents. 2.7.5 Stand clamp The stand clamp for mounting the devices is located on the back of the device. The stand clamp can be rotated, and has detents at 90° intervals. Carrying grip Rotary stand clamp Securing screw The illustration alongside shows the securing slot in a horizontal position. This orientation of the stand clamp is for attaching the device to a standard rail. Figure 5: 18 Stand clamp at the back of the device (horizontal) User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Barkey autocontrol 3XPT Carrying grip Rotary stand clamp Securing screw The illustration alongside shows the securing slot in a vertical position. This orientation of the stand clamp is for attaching the device to an infusion stand. Figure 6: Stand clamp at the back of the device (vertical) User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 19 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system 2.8 2.8.1 Barkey autocontrol 3XPT Operation Getting started WARNING Before starting to use the device, check it for damage on each occasion. If the device is damaged, do not use it. Before commissioning the device, first the suitability of the installation location must be checked. Then the necessary cables can be connected. WARNING When selecting a location for the device it is essential that the distances from other devices with electromagnetic emissions are maintained as stated in this user manual. 2.8.1.1 Installation location The Barkey autocontrol 3XPT is designed for use as a fixed indoors installation. Mobile use is not intended. The Barkey autocontrol 3XPT must be attached to a standard rail or to an infusion stand. The connection ports and the buttons on the operating panel must be easy to access so that the display and the indicator lights can easily be read by the user of the device. WARNING Be sure to note the information in Chapters 0 and 0 of this user manual, which give instructions about the ambient conditions under which the device may not be used or under which its operation may be impaired. The device is ventilated from below. The ventilation slots on the underside of the device must not be covered or blocked so as to obstruct the air flow. The ventilation slots in the handle moulding allow the device to discharge heat to the environment. The ventilation slots must not be covered or blocked. CAUTION When carrying or turning the stand clamp, grip the device with one hand in the grip recess at the top back of the device. CAUTION Install the device so that the mains plug is accessible at all times and the mains plug can easily be withdrawn from the socket, for instance in an emergency. 20 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de Barkey autocontrol 3XPT User manual Barkey XPT heating system 2.8.1.2 Installing the device ► Hold the device at the grip recess at the top back and turn the stand clamp to the desired position. To fasten the device to an infusion stand, turn the stand clamp to the position where its slot is vertical. To fasten the device to a standard rail, turn the stand clamp to the position where its slot is horizontal. WARNING Do not clamp any cables or tubes in the stand clamp slot. ► Using the clamp, install the device on the standard rail or the infusion stand. For this purpose the standard rail or the infusion stand must be inserted to the full depth of the stand clamp slot. If the securing screw obstructs this it must be unscrewed anticlockwise to clear the slot. ► Secure the device by tightening the securing screw clockwise. If access to the screw is awkward you can try taking the device off again and turning the stand clamp through 180°. The orientation of the clamp is now the same as it was but the screw is on the opposite side which may allow it to be more easily screwed in and tightened. WARNING Tighten the securing screw so that the device is securely attached to the standard rail or the infusion stand. It must not wobble or be able to slide. If the device is not securely attached operation is made more difficult and the device may fall. 2.8.1.3 Connecting the power cord WARNING The power supply must correspond to the data on the device rating plate, the technical data in this user manual, and the applicable regulations for electrical installations. Route the power cord for the Barkey autocontrol 3XPT control unit so that it is does not generate interference for other devices. ► Connect the integral power cord for the device to the building's alternating current power supply by plugging the moulded-on plug into a power socket. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 21 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Barkey autocontrol 3XPT 2.8.1.4 Connecting the heaters CAUTION When connecting a heater make sure its plug is correctly aligned. It can be inserted in only one position. Do not force the plug when inserting it. Never unscrew the heater connection plug. This might damage the electronics contained within it. ► Connect a heater to one of the two ports provided for the purpose. These two ports can be found in the upper connection area immediately below the operating panel. To aid alignment, both plug and socket carry a red dot; these dots must lie one above the other. Knurled sleeve The heater connection plugs are provided with catches when engage automatically when they are plugged in thus preventing accidental unplugging. ► First release the catch by pulling back the knurled sleeve on the heater connection plug. Figure 7: Heater ► connection plug If you wish you can connect a second heater to the other port provided for the purpose. NOTE Heaters can be plugged in even when the Barkey autocontrol 3XPT is already switched on. The various types of heater are detected automatically and the controls are set up correctly for them. WARNING When a heater is plugged in to a Barkey autocontrol 3XPT that is already switched on, it must remain connected for at least 6 seconds in order that the parameters stored in the heater can be correctly read and recognised. Therefore do not change over any heaters within this period. Similarly after disconnecting a heater from the Barkey autocontrol 3XPT, you must wait at least 6 seconds before connecting another heater to the same port. 22 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de Barkey autocontrol 3XPT User manual Barkey XPT heating system 2.8.1.5 Connecting an optional temperature measurement sensor ► If desired you may connect a temperature measurement sensor for sensing the external temperature. The 3-pin port provided for this is located in the lower connection area of the device on the right hand side viewed from the front. The port of the left is of the same type; it is provided for customised extensions of the Barkey autocontrol 3XPT and is not generally connected internally. WARNING Only temperature measurement sensors provided by Barkey GmbH & Co. KG for this purpose may be connected. At present a ambient temperature measurement sensor with a 5 cm long connection lead and a general-purpose external temperature measurement sensor with a 2.8 m long connection lead are available. Measurement sensors may not be used for measuring patients' body temperatures. CAUTION When connecting a temperature measurement sensor make sure its plug is correctly aligned. It can be inserted in only one position. Do not force the plug when inserting it. Use the union nut to secure the plug connection. 2.8.1.6 Switching on ► Press the top button on the operating panel to turn the device on. A green operation indicator light (LED) to the left of the On/Off button lights up to confirm availability of power. The yellow background illumination of the display, the two orange indicator lights (LEDs) for channels 1 and 2 and the yellow fault indicator light (LED) flash twice, and at the same time an acoustic buzzer sounds. WARNING Make sure that the flashing and the acoustic signal are executed by the device and that they are clearly visible / audible. This is required for confirmation that the alarm system safety devices are operating correctly. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Barkey autocontrol 3XPT 2.8.1.7 Login screen autocontrol 3XPT For approx. 10 seconds the display shows: the Barkey logo the device name An internal system test is in progress during this time. Figure 8: Login screen 2.8.1.8 Main screen Channel 1: Channel 2: autoline autotherm Set 41.0 Set 38.5 39.3°C38.5°C Menu Then the display shows the main screen with the following data separately for each channel: the name of the type of heater that is connected the set temperature value the actual measured temperature The actual temperature is shown in large size digits. Figure 9: Main screen If one of the channels has no heater connected to it, the three display digits for that channel are blank. Once heaters are connected they are supplied with power and regulated according to the appropriate values, then heated to the displayed temperature value and maintained at this temperature. In addition to the data shown on the display the connection of heaters is also indicated by the respective yellow indicator lights (LEDs) which are located to the left and right of the display. The menu can be called up by pressing the centre button under the display. 24 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de Barkey autocontrol 3XPT User manual Barkey XPT heating system 2.8.1.9 Switching off ► Press the top button on the operating panel when you wish to turn the device on. NOTE The device can be switched off at any time. This shuts down the power supply to all the heaters that are connected. 2.8.2 Calling up the devices functions that are displayed as menu items 2.8.2.1 Menu overview The menu allows various device functions to be called up. It is divided into two screens. Bildschirm Menu item Temperature measurement The temperature display of an optional temperature measurement sensor that is connected can be called up. Set value channel 1 The set value for the heater connected to channel 1 can be changed. Set value channel 2 The set value for the heater connected to channel 2 can be changed. Nighttime mode The background illumination of the display and the yellow lights (LEDs) can be switched off. 1 next Language Information System 2 Application / device function Switching over to the second menu screen. Eine Sprache for die Menütexte kann gewählt werden. The display of information about the control unit can be called up. Channel 1 information The display of information about the heater connected to channel 1 can be called up. Channel 2 information The display of information about the heater connected to channel 2 can be called up. back Switching back to the first menu screen. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 25 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Barkey autocontrol 3XPT 2.8.2.2 Calling up the menu ► In the main screen, press the "Menu" button to start the menu system. ► Press the left selection button "Select" Temperature measurement Set value channel 1 Set value channel 2 Nighttime mode next -> Select OK to highlight the next menu item. ► Acknowledge the "OK" display with the confirmation button to call up a highlighted menu item. ► Press the right hand selection button "End" to revert to the main screen. ► Use the left hand selection button End "Select" to highlight the "back" menu item and press the left hand selection button "Select" to revert to the menu screen 2. Figure 10: Menu screen 1 ► Press the left selection button "Select" Language Information System Channel 1 information Channel 2 information <- back Select OK End to highlight the next menu item. ► Acknowledge the "OK" display with the confirmation button to call up a highlighted menu item. ► Press the right hand selection button "End" to revert to the main screen. ► Use the left hand selection button "Select" to highlight the "next" menu item and press the left hand selection button "Select" to revert to the menu screen 1. Figure 11: Menu screen 2 NOTE The display automatically returns to the main screen if no button is pressed within 30 seconds. The functions of the three buttons change depending on the selected option and are described below for the individual menu items. 26 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Barkey autocontrol 3XPT 2.8.2.3 "Temperature measurement" device function The temperature of an external ambient temperature sensor or of an external temperature sensor is shown in the display, provided a temperature measurement sensor is connected. WARNING Only temperature measurement sensors approved by Barkey GmbH & Co. KG for this purpose may be connected. Measurement sensors may not be used for measuring patients' body temperatures or for other medical purposes. ► In the main screen, press the "Menu" button to start the menu system. Temperature measurement Set value channel 1 Set value channel 2 Nighttime mode next -> ► Acknowledge the "OK" display with Select OK the confirmation button to call up the first "Temperature measurement" menu item. End Figure 12: Menu screen 1 Ambient temperature: 20.9°C external sensor: --.-°C Back The adjacent "Temperature measurement" screen shows the temperature measured by the ambient temperature measurement sensor that is connected. ► Press the confirmation button ("Back") to revert to menu screen 1. Figure 13: "Temperature measurement" screen (1) (Ambient temperature) User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 27 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Barkey autocontrol 3XPT Ambient temperature: --.-°C external sensor: 35.5°C Back The adjacent "Temperature measurement" screen shows the temperature measured by the external temperature measurement sensor that is connected. ► Press the confirmation button ("Back") to revert to menu screen 1. Figure 14: "Temperature measurement" screen (2) (external sensor) If no external ambient temperature sensor or external temperature sensor is connected, horizontal dashes are shown. NOTE After 30 seconds the display automatically reverts to the main screen. 28 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Barkey autocontrol 3XPT 2.8.2.4 "Set value channel 1" and "Set value channel 2" device functions The menu items "Set value channel 1" and "Set value channel 2" allow the temperature of the heater to be set to a range that is safe for the patient. Barkey XPT heating system heaters have a device-specific default set temperature value and a temperature range within which a set temperature value different from the default value can be set: Device Default temperature Temperature range Barkey autoline XPT 4R 41°C 33 °C ... 43°C Barkey autotherm XPT 38.5°C 33 °C ... 41°C The set temperature value can be varied in "0.5 °C steps". NOTE The set value is set separately for each channel. It can be varied at any time. The last setting of the set value for a channel remains in force until a different heater is connected to this channel, or until the Barkey autocontrol 3XPT is switched off. The set value must always be set higher than the currently prevailing ambient temperature, otherwise an "undertemperature error" will be triggered. ► Press the“Menu“ button on the main screen to start the menu system. Temperature measurement Set value channel 1 Set value channel 2 Nighttime mode next -> ► Press the left selection button ("Select") repeatedly until the desired channel is highlighted. ► Acknowledge the "OK" display with Select OK End the confirmation button to call up the highlighted menu item. Figure 15: Menu screen 1 NOTE The set value setting can be selected only for a channel to which a heater is connected. Otherwise the highlighting reverts automatically to the "Temperature measurement" menu item. Channel 1 is used here as an example; the description applies equally to both channels. The procedure for setting the set temperature value is identical for both channels. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 29 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Barkey autocontrol 3XPT The "Channel 1 set value" that is called up shows the channel number, the type of heater that is connected and its current set temperature value. In addition the set temperature value is shown in large digits. The "°C" now flashes to indicate that a setting procedure has been initiated. Channel 1: autoline Set 37.0 37.0 The two selection buttons ("-" and "+") can be used to increment or decrement the set temperature. °C ► Press "-" or "+" repeasted until the large characters show the desired set temperature. ► Acknowledge the "OK" display with - OK + the confirmation button to load the temperature setting. Figure 16: "Channel 1 set value" screen (1) Channel 1: autoline Set 41.0 41.0 - °C BACK The character "°C" now stops flashing and the set temperature value is shown at top in small digits. + ► Press the "Back" button to revert to menu screen 1. Figure 17: "Channel 1 set value" screen (2) NOTE If the "Back" button is not pressed the display will automatically revert to the main screen after about 30 seconds. 30 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Barkey autocontrol 3XPT 2.8.2.5 "Overnight mode" device function The background illumination of the display and the orange indicator lights (LEDs) for the two channels can be switched off for overnight mode in the patient's room. To check the main screen display, overnight mode can be interrupted briefly without having to switch it off permanently. ► In the main screen, press the confirm Temperature measurement Set value channel 1 Set value channel 2 Nighttime mode next -> button ("Menu") to start the menu system. ► Press the left selection button ("Select") repeatedly until the "Overnight mode" menu item is highlighted. ► Acknowledge the "OK" display with Select OK End the confirmation button to call up the highlighted menu item. Figure 18: Menu screen 1 The "Overnight mode" screen that is called up allows overnight mode to be switched on and off. Nighttime mode (illumination of the displays only if a button is pressed) The two selection buttons "Off" and "On") allow the illumination to be switched off and on, Illumination ► Press "Off" to start overnight mode. off Back on ► Press "On" to stop overnight mode. Figure 19: "Overnight mode" screen NOTE If whilst in overnight mode any of the three buttons under the display is pressed, the illumination is switched on for 30 seconds. If during this 30 seconds no further button is pressed the background illumination and indicator lights switch off again automatically and overnight mode is resumed. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 31 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Barkey autocontrol 3XPT 2.8.2.6 "Language selection" device function This menu item selects the desired language for displaying the menu texts. The selected language is retained in the memory even after the device is switched off. ► In the main screen, press the "Menu" button to start the menu system. Temperature measurement Set value channel 1 Set value channel 2 Nighttime mode next -> ► Press the left selection button Select OK End ("Select") repeatedly until the second menu screen appears. Figure 20: Menu screen 1 Language Information System Channel 1 information Channel 2 information <- back ► Acknowledge the "OK" display with Select OK End the confirmation button to call up the highlighted first menu item "Language selection". Figure 21: Menu screen 2 The menu item "Language selection" offers four available languages. Please select the language: German Dutch Italian French Select OK ► Press the left selection button ("Select") repeatedly until the desired language is highlighted. ► Acknowledge the "OK" display with the confirmation button to activate the highlighted language. The display automatically reverts to the second menu screen End Figure 22: "Language selection" screen NOTE If no button is pressed within 30 seconds of calling up the menu item the display automatically reverts to the main screen. 32 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Barkey autocontrol 3XPT 2.8.2.7 "Information System" device function The purpose of this menu item is to display important information about the Barkey autocontrol 3XPT control unit. ► In the main screen, press the "Menu" button to start the menu system. Temperature measurement Set value channel 1 Set value channel 2 Nighttime mode next -> ► Press the left selection button Select Figure 23: Menu screenOK 1 End Language Information System Channel 1 information Channel 2 information <- back ("Select") repeatedly until the second menu screen appears. ► Press the left selection button ("Select") repeatedly until the "Information System" menu item is highlighted. ► Acknowledge the "OK" display with Select OK End the confirmation button to call up the highlighted menu item. Figure 24: Menu screen 2 The following information about the device is displayed under the "Information System" menu item: System information: Name : 3XPT SN : 1206012 Man. date. : 08.02.07 Calibr. : 15.02.07 Version : sv 1.5 Device designation Serial number Date of manufacture Date of last servicing/TSI Version number of the device software ► Press the confirmation button Back ("Back") to revert to the second menu screen. Figure 25: "Information System" screen NOTE If no button is pressed within 30 seconds of calling up the menu item the display reverts to the main screen. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 33 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Barkey autocontrol 3XPT 2.8.2.8 "Channel 1 information" and "Channel 2 information" device functions The purpose of this menu item is to display important information about the heaters that are currently connected. ► In the main screen, press the "Menu" button to start the menu system. Temperature measurement Set value channel 1 Set value channel 2 Nighttime mode next -> ► Press the left selection button Select OK End ("Select") repeatedly until the second menu screen appears. Figure 26: Menu screen 1 Language Information System Channel 1 information Channel 2 information <- back ► Press the left selection button ("Select") repeatedly until "Information channel 1" is highlighted. ► Acknowledge the "OK" display with Select OK End the confirmation button to call up the highlighted menu item. Figure 27: Menu screen 2 NOTE This menu item can be selected only for a channel to which a heater is connected. Otherwise the menu item cannot be called up and the highlighting reverts to the "Language selection" menu item. Channel 1 is used here as an example; the description applies equally to both channels. The display of information is presented in the same way for both channels. 34 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de Barkey autocontrol 3XPT User manual Barkey XPT heating system The following information about the heater that is connected is shown under the "Channel 1 information" menu item: Information: Channel 1 Name : autoline SN : 2300000 Man. date. : 12.02.07 Calibr. : 13.02.07 Back Device designation Serial number Date of manufacture Date of last servicing/TSI ► Press the confirmation button ("Back") to revert to the second menu screen. Figure 28: "Channel 1 information" screen NOTE If no button is pressed within 30 seconds of calling up the menu item the display automatically reverts to the main screen. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 35 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system 3 Barkey autoline XPT 4R Barkey autoline XPT 4R Figure 29: Barkey autoline XPT 4R The Barkey autoline XPT 4R is an active therapeutic medical device in the form of an active heater jacket which heats an infusion tube or, in conjunction with haemodialysis devices, heats the blood return flow and prevents it cooling. The infusion tubes to be warmed are inserted into and enveloped within the Barkey autoline XPT 4R heater profile. This means there is the maximum amount of heat transfer from the heater profile to the fluid to be warmed. Des Barkey autoline XPT 4R is connected to one of the two channels of a Barkey autocontrol 3XPT unit, which regulates the temperature of the heater. The Barkey autocontrol 3XPT detects a Barkey autoline XPT 4R heater as it is connected and automatically performs the settings for the relevant control requirements. The autoline XPT 4R stand support is used for securing the heater profile to the infusion stand. The Barkey autoline XPT 4R heater profile is available in several versions with different internal diameters and different maximum temperatures. The maximum temperature setting has to be indicated as a variant when ordering. Available Barkey autoline XPT 4R heater profiles: Device designation 36 Length Internal diameter max. temperature Barkey autoline XPT 4R 1.5 m approx. 5 mm 37, 40, 41 or 43°C Barkey autoline XPT 4R 1.5 m approx. 7 mm 37, 40, 41 or 43°C User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de Barkey autoline XPT 4R 3.1 User manual Barkey XPT heating system Device functions The Barkey autoline XPT 4R is an electronically regulated heater for heating and keeping warm infusion fluids on the way to the patient. The thermal output of the heater is applied to the infusion tube through which the fluid is flowing. For this purpose the device is constructed as a heater profile of resilient material with a slit into which the infusion tube can easily be inserted. A support with a stand clamp permits positioning of the heater profile on an infusion stand. The heater profile is made of biologically compatible silicone which has been proven to cause no skin irritation or other toxic reactions. This means the Barkey autoline XPT 4R is particularly suited to intraoperative use. The Barkey autocontrol 3XPT control unit in conjunction with the Barkey autoline XPT 4R offers a very high degree of patient safety by means of a multi-layer safety concept and independent overtemperature protection. The Barkey autocontrol 3XPT controls the thermal output of the Barkey autoline XPT 4R to which it is connected in conformity with the specified value saved in the heater. The user can change the set value at the Barkey autocontrol 3XPT to the respective maximum temperature adjustable. The maximum temperature of the autoline XPT 4R is factory set as desired by the customer for 37, 40, 41 or 43 ° C. 3.2 Safety features Safe heating conditions at the Barkey autoline XPT 4R by conformity with the pre-set temperature The temperature can be varied only within a safe range Double-acting overtemperature protection shuts the device down safely on overtemperature No degradation of important and sensitive biological components of the blood and blood products due to excessive temperatures Plain local language text displays of the set temperature value and actual temperature of the Barkey autoline XPT 4R on the large display of the Barkey autocontrol 3XPT Device is designed for continuous operation Operation with non-hazardous safety low voltage Heater elements are embedded corrosion-free in plastic Secure attachment of the device to a stand clamp Hygienic support attachment of the end of the heater profile when not in use User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 37 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system 3.3 Barkey autoline XPT 4R Intended purpose / Use for the intended purpose The Barkey autoline XPT 4R is an active therapeutic medical device in the form of an active heater jacket which heats an infusion tube or, in conjunction with haemodialysis devices, heats the blood return flow and prevents it cooling. A precondition for the correct use of the Barkey autoline XPT 4R is that it has been correctly installed and used in compliance with all safety instructions as described in this user manual. The Barkey autocontrol 3XPT control unit must also be correctly installed as described in this user manual. These summarised statements on the intended use of the device are supplemented in this user manual by specific descriptions of the use and handling of the device. You will find these descriptions in Chapters 3.4 to 3.6 of this user manual. Please use these chapters to find specific information about usage of the device in individual cases. WARNING Barkey XPT heaters may be operated only in conjunction with the Barkey autocontrol 3XPT control unit. If infusion solutions or medicaments are being kept warm the user must ensure that the temperature setting in the control unit is appropriate for them and will not impair their effectiveness. If this is not so, the user must adjust the temperature settings to values appropriate to the infusion solutions or medicaments. If despite the use of biologically compatible materials the patient suffers skin irritation, the heater must be removed from the patient immediately. 38 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de Barkey autoline XPT 4R 3.4 3.4.1 User manual Barkey XPT heating system Safety instructions Safety instructions for using the device The device and its system components must be checked WARNING before every use to ensure they are all intact. Damaged devices must not be used. In order not to put the safety of the patient or operator at risk, do not use the device if one of the following conditions applies: - The power cords, mains plugs, control leads, plugs or sockets are damaged or worn - The housing and/or operating panel is damaged - The device has been dropped or its internal electronic components have become wet. - The device does not heat correctly (as displayed by optical and acoustic alarms). - The yellow alarm lamp and/or acoustic alarm is activated - The heater is damaged. All electrical installations must comply with the relevant applicable regulations and standards, in addition to the specifications stated by the manufacturer. Before using the Barkey autoline XPT 4R heater, thoroughly read all the relevant chapters of this user manual together with all the chapters on the Barkey autocontrol 3XPT control unit. Before using temperature measurement sensors, read Chapter 2 of this user manual. Only use the heater in accordance with the regulations as described previously and in accordance with the processes described in this user manual. Barkey XPT heaters may be operated only in conjunction with the Barkey autocontrol 3XPT control unit. Never attach the heater in an improvised fashion, instead always attach it as described in this user manual. Do not clamp any cables or tubes in the stand clamp slot of the clamp that is used to mount the heater. The head of the heater where the control cable enters the heater profile must be inserted into the support provided for it. The head must not be covered, insulated, heated or cooled. Tighten the securing screw on the stand support so that the support is securely fastened to the infusion stand. It must not wobble or be able to slide. If the support is not securely fixed it can slip down taking the heater profile and infusion tube with it, thereby restricting or preventing infusion flow. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 39 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Barkey autoline XPT 4R The heater profile must not be kinked, damaged or shortened. WARNING CAUTION 40 If the infusion is brought to a stop and at the same time the heater profile starts to cool down, the risk of overheating the infusion tube cannot be excluded. The heater profile must not be cooled or heated. Route the heater profile through the air without obstruction. Do not cover it with dressing material, cloths, bedcovers or warm air blankets. Do not expose the heater profile to direct sunlight or thermal radiation, nor run it into or through incubators. If despite the use of biologically compatible materials the patient suffers skin irritation, the heater must be removed from the patient immediately. Before the Barkey autoline XPT 4R is used with a control unit, both devices must be allowed to acclimatise at the place of use for at least an hour at ambient temperature. Before using the heating system, perform a disinfectant wipe of the heater and all the other components. Before cleaning the heater it must be disconnected from the mains supply by withdrawing the power plug from the mains socket. After being connected to the Barkey autocontrol 3XPT, a heater must remain connected for at least 6 seconds. Otherwise the parameters saved in the heater will not be recognised correctly. After disconnecting a heater from the Barkey autocontrol 3XPT, you must wait at least 6 seconds before connecting another heater. Otherwise the parameters saved in the heater will not be recognised correctly. If infusion solutions or medicaments are being heated the user must ensure that the temperature setting in the control unit is appropriate for them and will not impair their effectiveness. If this is not so, the user must adjust the temperature settings to values appropriate to the infusion solutions or medicaments. The infusion heating system can be used at ambient temperatures from +10°C to +40°C and is suitable for continuous operation. If the overtemperature alarm sounds, the temperature of the heater must be allowed to fall below the maximum setpoint. Otherwise the supply of liquids to the patient must be stopped immediately. The heater must not be used if it has a fault. The heater should be examined by Barkey GmbH & Co. KG or by an authorised person. If the ambient temperature is higher than the control unit temperature setting, this may lead to an overtemperature alarm because the heater has been heated by the ambient to an excessive temperature. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de Barkey autoline XPT 4R 3.4.2 User manual Barkey XPT heating system Safety instructions on handling the device Before using the Barkey autoline XPT 4R heater, thoroughly read all the relevant chapters of this user manual together with WARNING all the chapters on the Barkey autocontrol 3XPT control unit. All electrical installations must comply with the relevant applicable regulations and standards, in addition to the specifications stated by the manufacturer. The user is responsible for correct installation. The control unit mains plug must be withdrawn from the mains socket to ensure safe isolation of the heater from the power supply. Do not sharply kink the heater or fold it! Do not pierce the heater with sharp objects! Do not apply external heating or cooling to the heater Do not attempt to modify the shape of the heater or damage it Using cleaning products and disinfectants other than as described in this User manual can damage the device. Check with the manufacturer before using cleaning agents which are not expressly recommended for use. In particular, you are warned against the use of the following solutions: - halogenated aromatic and aliphatic solvents; - ketonic solvents. The heater contains no parts which can be repaired by the user. Do not carry out repairs to the heater yourself. Please contact Barkey GmbH & Co. KG or your medical technician service, who can request information about repair from the manufacturer. Repairs and modifications to the device may only be carried out by Barkey GmbH & Co. KG or authorised personnel. An annual technical safety inspection must be carried out by qualified service personnel or employees of Barkey GmbH & Co. KG. The rating plate of the heater is attached to the cable near the connection plug. Amongst other things, this specified the serial CAUTION number ("SN") of the heater. Never unscrew the heater connection plug. This might damage the electronics contained within it. When connecting the heater make sure its plug is correctly aligned. It can be inserted in only one position. Do not force the plug when inserting it. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 41 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system 3.4.3 42 Barkey autoline XPT 4R Safety instructions and environmental influences The influence of strong electromagnetic fields (e.g. through the use of HF therapy or surgical devices) can lead to malfunctions WARNING in devices of the Barkey XPT heating system. If interference of this type occurs, increase the distance between the XPT device suffering interference and the device causing the interference, or do not operate both devices at the same time. XPT devices work perfectly within the interference limit values set in the EN 60601-1-2 standard. XPT devices can be affected by interference outside the limit values set by EN 60601-1-2. The Barkey autoline XPT 4R may not be used immediately next to other devices or stacked on top of other devices. If it is necessary to operate the device next to or stacked on top of other devices, the Barkey autoline XPT 4R must be monitored to check that it is working correctly in this situation. Portable and mobile HF communication equipment such as mobile phones can affect XPT devices. Do not use the device in the immediate vicinity of flammable materials (e.g. gases, liquids), flammable mixtures of anaesthetic substances with air, flammable mixtures of anaesthetic substances with oxygen or laughing gas whose flashpoint is below 50°C. It is imperative that the device is not used in areas in which alcoholic disinfectants and anaesthetising substances are being used at the same time. XPT devices may not be operated in the immediate vicinity of devices with a high thermal discharge output. Control cables must be laid where they cannot affect the operation of any other devices. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Barkey autoline XPT 4R 3.5 3.5.1 Components of the heater Wärmeprofil mit Steuerleitung Support with stand clamp Heater profile head Heater profile Control cable Connection plug Figure 30: Heater profile with control cable and support Heater profile The heater profile is made of biologically compatible silicone and has a slit to accommodate the infusion tube. The heater profile contains the heater element and the temperature sensors as well as the necessary cabling. Two heater profiles are available, both the same length but with different internal diameters. The maximum temperature of the autoline 4R XPT is factory preset according to the needs of the user to 37, 40, 41 or 43°C: Device designation Length Internal diameter max. temperature Barkey autoline XPT 4R 1.5 m approx. 5 mm 37, 40, 41 or 43°C Barkey autoline XPT 4R 1.5 m approx. 7 mm 37, 40, 41 or 43°C Control cable This allows the control unit to supply the heater profile with a safety low voltage for operation of the heater element. It also reports back to the control unit the measured values from the temperature sensors incorporated in the heater profile. The control cable is mechanically connected to the heater profile. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 43 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Barkey autoline XPT 4R Connection plug The multi-pin connection plug connects the heater to the control unit. The plug automatically locks into place when it is inserted. To withdraw the plug, release the catch by pulling on the knurled sleeve of the plug. The plug contains the electronics which store the parameters of the heater. 3.5.2 Support with stand clamp A support is supplied with the Barkey autoline XPT 4R heater so that it can be attached to an infusion stand. So that the entire heated length of the Barkey autoline XPT 4R can be used, the support is designed to allow adjustment but regarding the height and also the distance from the infusion stand to be selected. In this way the exact position can be established to suit various different shapes of infusion vessels. 3.6 Getting started Before commissioning the heater, first the suitability of the installation location must be checked. Then the necessary cables can be connected. WARNING The device and its system components must be checked before every use to ensure they are all intact. Damaged devices must not be used. In order not to put the safety of the patient or operator at risk, do not use the device if one of the following conditions applies: - The power cords, mains plugs, control leads, plugs or sockets are damaged or worn - The casing or operating panel is damaged - The device has been dropped or its internal electronic components have become wet. - The device does not heat correctly (as displayed by optical and acoustic alarms). - The yellow alarm lamp and/or acoustic alarm on the control unit is activated - The heater is damaged. 3.6.1 Installation location The infusion heating system consisting of the Barkey autocontrol 3XPT and Barkey autoline XPT 4R is intended for use indoors as a fixed installation. Mobile use is not intended. The Barkey autoline XPT 4R must be mounted on an infusion stand. WARNING The infusion heating system can be used at ambient temperatures from +10°C to +40°C and is suitable for continuous operation. Be sure to comply with the safety instructions in the respective chapters of this user manual, which give instructions about the environmental conditions under which the heater may not be used or under which its operation may be impaired. 44 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de Barkey autoline XPT 4R 3.6.2 User manual Barkey XPT heating system Installing the heater WARNING Never attach the heater in an improvised fashion, instead always attach it as described in this user manual. Do not clamp any cables or tubes in the stand clamp slot of the clamp that is used to mount the heater. WARNING Tighten the securing screw so that the support is securely fastened to the infusion stand. It must not wobble or be able to slide. If the support is not securely fixed, it can slip down taking the heater profile and infusion tube with it, thereby restricting or preventing infusion flow. ► Attach the support at the correct position on the infusion stand using the securing screw. ► Insert the infusion tube, starting at the end of the heater profile. Insert the heater profile into the support and route the control cable to the Barkey autocontrol 3XPT. Connect the connection plug to the Barkey autocontrol 3XPT. ► Insert the free end of the heater profile into the recess attached to the stand clamp of the support. ► Secure the stand clamp of the heater support close to the infusion tube on the infusion stand, so that the mounting for the head faces the infusion tube. Secure the support by tightening the securing screw clockwise. For this purpose place the stand clamp on the infusion stand. At this point the infusion stand must rest on the bottom of the attachment slot. If the securing screw obstructs this it must be unscrewed anticlockwise to clear the slot. ► Insert the head of the heater profile from above into the mounting for the head, so that the heater profile runs down from it. WARNING The heater profile must not be covered, insulated, heated or cooled. If the infusion is brought to a stop and at the same time the heater profile starts to cool down, the risk of overheating the infusion tube cannot be excluded. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 45 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system 3.6.3 Barkey autoline XPT 4R Inserting the infusion tube WARNING Before using the heating system, perform a disinfectant wipe of the heater and all the other components. Each time before using the heater, check it including the control cable and the plug for mechanical damage. If the heater is damaged, do not use it. ► Insert the infusion tube into the heater profile. Experience shows it is best to start at the patient's end of the infusion tube. Insert the infusion tube about 3 cm up from the Luer-Lock connection into the end of the heater profile. Use your thumbs to press the infusion tube along the slit in the heater profile. To accommodate a metering restrictor the tube can be brought out of the heater profile at any point or at the device head. Figure 31: Inserting the infusion tube WARNING Make sure that the infusion tube is not twisted, nor kinked where it enters or exits the heater profile. Such twists or kinks can restrict or prevent the infusion flow. The heater profile must not be kinked, damaged or shortened. 46 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de Barkey autoline XPT 4R 3.6.4 User manual Barkey XPT heating system Connecting the heater WARNING Before the heater can be connected, the Barkey autocontrol 3XPT control unit must have been correctly mounted on a standard rail or infusion stand. You will find particulars for this in Chapters 0 and 2.8 of this user manual. Before the Barkey autoline XPT 4R is used with a control unit, both devices must be allowed to acclimatise at the place of use for at least an hour at ambient temperature. CAUTION When connecting the heater make sure its plug is correctly aligned. It can be inserted in only one position. Do not force the plug when inserting it. Never unscrew the heater connection plug. This might damage the electronics contained within it. WARNING After being connected to the Barkey autocontrol 3XPT, a heater must remain connected for at least 6 seconds. Otherwise the parameters saved in the heater will not be recognised correctly. Therefore do not change over the heater within this period. After disconnecting a heater from the Barkey autocontrol 3XPT, you must wait at least 6 seconds before connecting another heater. Otherwise the parameters saved in the heater will not be recognised correctly. Therefore do not change over any heaters within this period. The Barkey autoline XPT 4R heater can be connected to the Barkey autocontrol 3XPT control unit, irrespective of whether the control unit is switched on or not. The heater and the control unit support "hot-plugging", so the parameters are read electronically and correct regulation is established even if the control unit is switched on when the connection to the heater is made. The connection plug for the heater is inserted into the relevant socket for channel 1 or 2 at the Barkey autocontrol 3XPT control unit (it is the user's free choice which of the two channels is selected for connecting the heater). ► Connect the heater to either one of the sockets provided for the purpose on the Barkey autocontrol 3XPT control unit. The two sockets are located immediately underneath the display on the device. To aid alignment, both plug and socket carry a red dot; these dots must lie one above the other. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 47 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Barkey autoline XPT 4R Knurled sleeve The heater connection plug is provided with a catch when engages automatically when it is plugged in, thus preventing accidental unplugging. ► To withdraw the connection plug, release the catch by pulling back the knurled sleeve on the connection plug. Figure 32: Heater connection plug NOTE The heater can be plugged in even when the Barkey autocontrol 3XPT is already switched on. The heater is detected automatically and the controls set up correctly for it. ► If the Barkey autocontrol 3XPT control unit was not already in operation when the heater was connected, now switch it on. You will find particulars for this in Chapters 0 and 2.8 of this user manual. CAUTION When a heater is plugged in to a Barkey autocontrol 3XPT that is already switched on, it must remain connected for at least 6 seconds in order that the parameters stored in the heater can be correctly read and recognised. Therefore do not change over the heater within this period. 48 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Barkey autotherm XPT 4 Barkey autotherm XPT Figure 33: Barkey autotherm XPT The Barkey autotherm XPT is an active therapeutic medical device in the form of an active heater jacket which heats pre-heated blood conserves, infusion bottles or bags and prevents them cooling. The 3XPT infusion heating system can be with infusions in all cases where it is necessary to prevent the patient suffering a fall in temperature. The Barkey autotherm XPT is connected to one of the two channels of a Barkey autocontrol 3XPT unit, which regulates the temperature of the heater. The Barkey autocontrol 3XPT detects a Barkey autotherm XPT heater as it is connected and automatically performs the settings for the relevant control requirements. The Barkey autotherm XPT heater jacket is available in various versions suitable for different infusion vessels: Designation Description Barkey autotherm 1 for round bottles 500 ml DIN (approx. 75 mm diameter) Infusion bags 250 - 300 ml Barkey autotherm 2 for round bottles 1000 ml DIN (approx. 90 mm diameter) for round bottles 500 ml ISO (approx. 90 mm diameter) Infusion bags 500 ml Barkey autotherm 3 for round bottles 1000 ml ISO (approx. 100 mm diameter) Barkey autotherm 4 for infusion bags (plastic) 250 ml to 400 ml Barkey autotherm 5 for rund bottles (glass) 250 ml DIN (approx. 65 mm diameter) Barkey autotherm s Made to customer order User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 49 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system 4.1 Barkey autotherm XPT Device functions The Barkey autotherm XPT is an electronically regulated active heater jacket for heating and keeping warm pre-heated blood conserves, infusion bottles or bags. Heat transfer characteristics are directly dependent on the matching shape of the bottle or bag. The device is available in a variety of versions appropriate to this application. It is designed as a jacket open at one end which is suspended from the infusion hook. The vessel containing the liquid is then suspended within the jacket. Infusion bottles thus require no additional suspension point. The Barkey autocontrol 3XPT control unit in conjunction with the Barkey autotherm XPT offers a very high degree of patient safety by means of a multi-layer safety concept and independent overtemperature protection. The Barkey autocontrol 3XPT controls the thermal output of the Barkey autotherm XPT to which it is connected in conformity with the specified value saved in the heater. The user can change the set value at the Barkey autocontrol 3XPT within the available range of +33 °C to +41°C for the Barkey autotherm XPT. 4.2 Safety features 50 Safe heating conditions at the Barkey autotherm XPT by conformity with pre-set temperatures The temperature can be varied only within a safe range Double-acting overtemperature protection shuts the device down safely on overtemperature No degradation of important and sensitive biological components of the blood and blood products due to excessive temperatures Plain local language text displays of the set temperature value and actual temperature of the Barkey autotherm XPT on the large display of the Barkey autocontrol 3XPT Device is designed for continuous operation Operation of the heater via a non-hazardous safety low voltage Corrosion-resistant aluminium with surface treatment Secure installation of the device on the infusion hook by means of a suspension eye User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de Barkey autotherm XPT 4.3 User manual Barkey XPT heating system Intended purpose / Use for the intended purpose The Barkey autotherm XPT is an active therapeutic medical device in the form of a heater jacket which heats pre-heated blood conserves, infusion bottles or bags and prevents them cooling. The 3XPT infusion heating system can be with infusions in all cases where it is necessary to prevent the patient suffering a fall in temperature due to the temperature of transfusion and infusion solutions. A precondition for the correct use of the Barkey autotherm XPT is that it has been correctly installed and used in compliance with all safety instructions as described in this user manual. The Barkey autocontrol 3XPT control unit must also be correctly installed as described in this user manual. These summarised statements on the intended use of the device are supplemented in this user manual by specific descriptions of the use and handling of the device. You will find these descriptions in Chapters 4.4 to 4.6of this user manual. Please use these chapters to find specific information about usage of the device in individual cases. WARNING Barkey XPT heaters may be operated only in conjunction with the Barkey autocontrol 3XPT control unit. If infusion solutions or medicaments are being heated or kept warm the user must ensure that the temperature setting in the control unit is appropriate for them and will not impair their effectiveness. If this is not so, the user must adjust the temperature settings to values appropriate to the infusion solutions or medicaments. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 51 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system 4.4 4.4.1 Barkey autotherm XPT Safety instructions Safety instructions for using the device The device and its system components must be checked WARNING before every use to ensure they are all intact. Damaged devices must not be used. In order not to put the safety of the patient or operator at risk, do not use the device if one of the following conditions applies: - The power cords, mains plugs, control leads, plugs or sockets are damaged or worn. - The housing and/or operating panel is damaged - The device has been dropped or its internal electronic components have become wet. - The device does not heat correctly (as displayed by optical and acoustic alarms). - The yellow alarm lamp and/or acoustic alarm on the control unit is activated - The heater is damaged. All electrical installations must comply with the relevant applicable regulations and standards, in addition to the specifications stated by the manufacturer. Before using the Barkey autotherm XPT heater, thoroughly read all the relevant chapters of this user manual together with all the chapters on the Barkey autocontrol 3XPT control unit. Before using temperature measurement sensors, read Chapter 2 of this user manual. Only use the heater in accordance with the regulations as described previously and in accordance with the processes described in this user manual. Barkey XPT heaters may be operated only in conjunction with the Barkey autocontrol 3XPT control unit. Never attach the heater in an improvised fashion, instead always attach it as described in this user manual. Before the Barkey autotherm XPT is used with a control unit, both devices must be allowed to acclimatise at the place of use for at least an hour at ambient temperature. Before using the heating system, perform a disinfectant wipe of the heater and all the other components. Before cleaning the heater it must be disconnected from the mains supply by withdrawing the power plug from the mains socket. After being connected to the Barkey autocontrol 3XPT, a heater must remain connected for at least 6 seconds. Otherwise the parameters saved in the heater will not be recognised correctly. 52 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de Barkey autotherm XPT WARNING CAUTION User manual Barkey XPT heating system After disconnecting a heater from the Barkey autocontrol 3XPT, you must wait at least 6 seconds before connecting another heater. Otherwise, the parameters saved in the heater cannot be correctly recognised. If infusion solutions or medicaments are being heated or kept warm the user must ensure that the temperature setting in the control unit is appropriate for them and will not impair their effectiveness. If this is not so, the user must adjust the temperature settings to values appropriate to the infusion solutions or medicaments. The user of the heater must ensure that the temperature set at the control unit is appropriate for the application concerned. The heater must not be laid on cold surfaces before or during use, less the temperature sensor is induced to report false readings. This can cause contact temperatures to exceed 41 °C. The infusion heating system can be used at ambient temperatures from +10°C to +40°C and is suitable for continuous operation. If the overtemperature alarm sounds, the temperature of the heater must be allowed to fall below 41°C. Otherwise the supply of liquids to the patient must be stopped immediately. The heater must not be used if it has a fault. The heater should be examined by Barkey GmbH & Co. KG or by an authorised person. If the ambient temperature is higher than the control unit temperature setting, this may lead to an overtemperature alarm because the heater has been heated by the ambient to an excessive temperature. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 53 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system 4.4.2 54 Barkey autotherm XPT Safety instructions on handling the device Before using the Barkey autotherm XPT heater, thoroughly read all the relevant chapters of this user manual together with WARNING all the chapters on the Barkey autocontrol 3XPT control unit. All electrical installations must comply with the relevant applicable regulations and standards, in addition to the specifications stated by the manufacturer. The user is responsible for correct installation. The control unit mains plug must be withdrawn from the mains socket to ensure safe isolation of the heater from the power supply. Using cleaning products and disinfectants other than as described in this User manual can damage the device. Check with the manufacturer before using cleaning agents which are not expressly recommended for use. In particular, you are warned against the use of the following solutions: - halogenated aromatic and aliphatic solvents; - ketonic solvents. Do not apply external heating or cooling to the heater The heater contains no parts which can be repaired by the user. Do not carry out repairs to the heater yourself. Please contact Barkey GmbH & Co. KG or your medical technician service, who can request information about repair from the manufacturer. Repairs and modifications to the device may only be carried out by Barkey GmbH & Co. KG or authorised personnel. An annual technical safety inspection must be carried out by qualified service personnel or employees of Barkey GmbH & Co. KG. The rating plate of the heater is attached to the cable near the connection plug. Amongst other things, this specified the serial CAUTION number ("SN") of the heater. Never unscrew the heater connection plug. This might damage the electronics contained within it. When connecting the heater make sure its plug is correctly aligned. It can be inserted in only one position. Do not force the plug when inserting it. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de Barkey autotherm XPT 4.4.3 User manual Barkey XPT heating system Safety instructions and environmental influences The influence of strong electromagnetic fields (e.g. through the use of HF therapy or surgical devices) can lead to malfunctions WARNING in devices of the Barkey XPT heating system. If interference of this type occurs, increase the distance between the XPT device suffering interference and the device causing the interference, or do not operate both devices at the same time. XPT devices work perfectly within the interference limit values set in the EN 60601-1-2 standard. XPT devices can be affected by interference outside the limit values set by EN 60601-1-2. The device may not be used immediately next to other devices or stacked on top of other devices. If it is necessary to operate the device next to or stacked on top of other devices, the device must be monitored to check that it is working correctly in this situation. Portable and mobile HF communication equipment such as mobile phones can affect XPT devices. Do not use XPT devices in the immediate vicinity of flammable materials (e.g. gases, liquids), flammable mixtures of anaesthetic substances with air, flammable mixtures of anaesthetic substances with oxygen or laughing gas whose flashpoint is below 50 ℃. In particular, it is imperative that XPT devices are not used in the same areas where alcohol disinfectants and anaesthetising substances are being used at the time. XPT devices may not be operated in the immediate vicinity of devices with a high thermal discharge output. Control cables must be laid where they cannot affect the operation of any other devices. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 55 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system 4.5 Barkey autotherm XPT Components of the heater Suspension eye Support Heater jacket Control cable Connection plug Figure 34: Heater jacket with support and connection lead Heater jacket The heater jacket is made of aluminium with surface treatment and has a slit at the side to accept liquid vessels to which an infusion tube is already attached. The infusion vessels can thus easily be suspended. An infusion bottle thus does not require a separate suspension from the infusion hook. The heater jacket contains the heater element and the temperature sensors as well as the necessary cabling. Support The heater jacket support has an eye at the top so that it can be suspended from the infusion hook on the infusion stand. If the hook is free to slide on the support this allows the infusion bag and its tube loop as well as the heater to be secured against accidentally falling down. Control cable This allows the control unit to supply the heater jacket with a safety low voltage for operation of the heater element. It also reports back to the control unit the measured values from the temperature sensors incorporated in the heater jacket. The control cable is connected to the heater jacket via a strain relief. 56 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de Barkey autotherm XPT User manual Barkey XPT heating system Connection plug The connection plug connects the heater to the control unit. The plug automatically locks into place when it is inserted. To withdraw the plug, release the catch by pulling on the knurled sleeve of the plug. The plug contains the electronics which store the parameters of the heater. 4.6 Getting started Before commissioning the heater, first the suitability of the installation location must be checked. Then the necessary cables can be connected. WARNING The device and its system components must be checked before every use to ensure they are all intact. Damaged devices must not be used. In order not to put the safety of the patient or operator at risk, do not use the device if one of the following conditions applies: 4.6.1 - The power cords, mains plugs, control leads, plugs or sockets are damaged or worn - The casing or operating panel is damaged - The device has been dropped or its internal electronic components have become wet. - The device does not heat correctly (as displayed by optical and acoustic alarms). - The yellow alarm lamp and/or acoustic alarm on the control unit is activated - The heater is damaged. Installation location The infusion heating system consisting of the Barkey autocontrol 3XPT and Barkey autotherm XPT is intended for use indoors as a fixed installation. Mobile use is not intended. The Barkey autotherm XPT must be mounted on an infusion stand. CAUTION The infusion heating system can be used at ambient temperatures from +10°C to +40°C and is suitable for continuous operation. Be sure to comply with the safety instructions in this user manual, which give instructions about the environmental conditions under which the heater may not be used or under which its operation may be impaired. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 57 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system 4.6.2 Barkey autotherm XPT Installing the heater WARNING Never attach the heater in an improvised fashion, instead always attach it as described below. ► Suspend the heater by hanging the eye on its support from the infusion hook on the infusion stand. WARNING Make sure the infusion tube is not twisted or pinched. WARNING The heater must not be cooled or heated. Simultaneous cooling of the heater can cause contact temperatures to exceed 41 °C. 4.6.3 Application WARNING Before using the heating system, perform a disinfectant wipe of the heater and all the other components. Each time before using the heater, check it including the control cable and the plug for mechanical damage. If the heater is damaged, do not use it. The heater must never be installed anywhere but on an infusion stand. ► 58 Always install the infusion bottle in the heater jacket with its opening facing downwards. The end of the bag must be attached to the hook on the device to prevent the infusion bag accidentally slipping down. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de Barkey autotherm XPT 4.6.4 User manual Barkey XPT heating system Connecting the heater WARNING Before the heater can be connected, the Barkey autocontrol 3XPT control unit must have been correctly mounted on a standard rail or infusion stand. You will find particulars for this in Chapters 0 and 2.8 of this user manual. Before the Barkey autotherm XPT is used with a control unit, both devices must be allowed to acclimatise at the place of use for at least an hour at ambient temperature. CAUTION When connecting the heater make sure its plug is correctly aligned. It can be inserted in only one position. Do not force the plug when inserting it. Never unscrew the heater connection plug. This might damage the electronics contained within it. WARNING After being connected to the Barkey autocontrol 3XPT, a heater must remain connected for at least 6 seconds. Otherwise, the parameters saved in the heater cannot be correctly recognised. Therefore do not change over the heater within this period. After disconnecting a heater from the Barkey autocontrol 3XPT, you must wait at least 6 seconds before connecting another heater. Otherwise the parameters saved in the heater will not be recognised correctly. Therefore do not change over the heater within this period. The Barkey autotherm XPT heater can be connected to the Barkey autocontrol 3XPT control unit, irrespective of whether the control unit is switched on or not. The heater and the control unit support "hot-plugging", so the parameters are read electronically and correct regulation is established even if the control unit is switched on when the connection to the heater is made. The connection plug for the heater is inserted into the relevant socket for channel 1 or 2 at the Barkey autocontrol 3XPT control unit (it is the user's free choice which of the two channels is selected for connecting the heater). User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 59 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system ► Barkey autotherm XPT Connect the heater to either one of the sockets provided for the purpose on the Barkey autocontrol 3XPT control unit. The two sockets are located immediately underneath the operating panel on the device. To aid alignment, both plug and socket carry a red dot; these dots must lie one above the other. Knurled sleeve The heater connection plug is provided with a catch when engages automatically when it is plugged in, thus preventing accidental unplugging. ► To withdraw the connection plug, release the catch by pulling back the knurled sleeve on the connection plug. Figure 35: Heater connection plug NOTE The heater can be plugged in even when the Barkey autocontrol 3XPT is already switched on. The heater is detected automatically and the controls set up correctly for it. CAUTION When a heater is plugged in to a Barkey autocontrol 3XPT that is already switched on, it must remain connected for at least 6 seconds in order that the parameters stored in the heater can be correctly read and recognised. Therefore do not change over the heaters within this period. ► 60 If the Barkey autocontrol 3XPT control unit was not already in operation when the heater was connected, now switch it on. You will find particulars for this in Chapters 0 and 2.8 of this user manual. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de Cleaning and care 5 User manual Barkey XPT heating system Cleaning and care The Barkey autocontrol 3XPT and XPT heaters are simple and easy to clean due to their smooth surfaces and rounded corners. The surfaces of the Barkey heating system XPT devices must be regularly cleaned and disinfection-wiped. WARNING Before cleaning or wipe-disinfecting the device: Switch off the Barkey autocontrol 3XPT using the On/Off switch at the top of the operating panel and withdraw the mains plug from the mains socket. Disconnect the heater from the control unit by releasing and withdrawing its connection plug. Do not pour cleaning fluid or disinfectant directly on to the heater. Always moisten a cloth and then use this cloth to clean the heater. Never apply cleaning agents to the ventilation openings on the control unit. Never use steam (i.e. in autoclaves), hot air or thermo-chemical cleaning solutions to disinfect the control unit and heater. You should use standard commercial preparations based on alcohol without oxygenreleasing components (with sodium hydrochloride with 1.4% bleach solution or aldehyde content < 0.2%) as a disinfectant. ► If possible clean the heater with a solution of soap and water. ► Dry the surfaces and use a surface disinfectant. Note the time to take effect stated by the disinfectant manufacturer! ► After allowing the disinfectant time to take effect, dry the device off with disposable tissues. WARNING The user should not use any other cleaning or decontamination methods than those recommended by the manufacturer. If you intend to use alternative cleaning products or decontaminants, you must first consult the manufacturer to ensure that the proposed methods will not damage the device. Otherwise, please refer to the hygiene measures and regulations which apply in your hospital. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 61 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system 6 Maintenance Maintenance Besides cleaning the heating system and performing the electrical safety checks, other maintenance measures that must be carried out are a regular safety check and regular battery replacement. These servicing operations may be carried out only by qualified service personnel or employees of Barkey GmbH & Co. KG. Training for medical technicians in checking and repairing the Barkey autocontrol 3XPT and the heaters for connection to it is available at the Barkey GmbH & Co. KG factory. Please call us on +49 (5202) 9801-30 for information about current availability and costs. At the end of this user manual you will find a blank form for a device master data sheet. You can use this as the front page of your servicing records file. 6.1 Technical safety inspection (TSI) As with all electronic devices, the Barkey XPT heating system's temperature regulation capabilities are subject to normal ageing and to the tolerances of the electronic components. To ensure that the temperature regulation capabilities of the Barkey autocontrol 3XPT are always within the stated tolerances, a technical safety inspection (TSI) must be carried out each year by qualified service personnel or by employees of Barkey GmbH & Co. KG (see Operators of Medical Products Directive § 6). Since the control unit can be operated with any of the heaters, the technical safety inspection for the control unit and for each heater must be performed separately. The technical safety inspection should also include the prescribed electrical safety check. As soon as a safety inspection for the control unit or a heater connected to it becomes due, when you switch on the control unit you will be automatically reminded of the requirement for safety inspection of the respective device by a message in the display. When the Barkey autocontrol 3XPT control unit is switched on it performs a self-check. A safety inspection therefore extends to the measurement functions at the signal inputs and the checking of the overtemperature protection function. Safety inspections also include checking the ventilation grilles at the air intake and outlet and cleaning them as necessary. Inspection of the heaters also includes checking the temperature value actually achieved by the heater. If the measured values lie outside the tolerances stated in the test certificate, the device must be recalibrated. Correction of the temperature setting can be performed only at Barkey GmbH & Co. KG. All the work necessary for servicing and for the TSI is described in a separate service manual which can be requested from Barkey GmbH & Co. KG. 62 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de Maintenance 6.2 User manual Barkey XPT heating system Replacing the battery CAUTION Only qualified service personnel and employees of Barkey GmbH & Co. KG may replace the battery. Please dispose of any batteries properly in accordance with regulations. The internal device clock and the language setting of the Barkey autocontrol 3XPT control unit will need to be reset after the battery has been changed. The device battery in the Barkey autocontrol 3XPT (lithium battery CR 1225, 3 V) must be replaced every 3 years. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 63 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system 7 Error messages Error messages Error messages are shown on the Barkey autocontrol 3XPT display as numeric codes. If an error occurs, the yellow “ for the last occurring error. ” light will light up. The display shows the code NOTE In some cases, the serial number of the device will not be shown with an error message. You can also find the serial number on the nameplate on the rear of the control unit or on the heater control lines. NOTE If several device errors occur, the display shows the error code for the error that occurred last. If an error message is displayed, please proceed as follows: The following error is present: No.: 104 ► Note the error message. ► Make a note of the error numbers and serial numbers. ► Switch off the device. ► Notify your medical technical service or the Barkey GmbH & Co. KG service department. Figure 36: Error message screen The various errors are divided into three numeric ranges: Error number range Device components affected 1 – 99 Barkey autocontrol 3XPT 100 – 199 Heater on channel 1 200 – 255 Heater on channel 2 A list of errors can be called up in the "Service" menu. This documents the six last errors that occurred. You can ask your medical technical service or the Barkey GmbH & Co. KG service department for more details. 64 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Error messages 7.1 Barkey autocontrol 3XPT error codes Error code 10, 12 Error description Comments Display is incorrect It is possible that no text is visible on the display. What appears the display may be incorrect. This also applies to the temperatures displayed. 20 to 23 Internal device data incorrect 30 Checksum for internal device data is incorrect 31 Checksum of the batterypowered backup memory is incorrect 32 44 45 Checksum of the program memory is incorrect Clock is incorrect Error when setting clock time Error when setting date Error when reading clock time Error when reading date Clock not running 50 Switch-off relay is faulty 51 The "watchdog timer" is defective 40 41 42 43 The "watchdog timer" has detected an error 61 No power supply for the heaters 70 to 73 Error during temperature measurement 74 Overtemperature in the control unit Replace battery (only by authorised specialist staff). Note: If the battery has run down, all text is displayed in the English language. Replace battery (only by authorised specialist staff). Then set the time and date. In the event of an error, this relay cuts off the power supply to the heaters. Note: Correct functioning of this relay is tested every time the device is switched on. A monitoring module which monitors the correct operation of the control unit. Note: Correct functioning of this component is tested every time the device is switched on. 60 Possible cause: F110 fuse faulty Possible cause: sensor break, sensor shortcircuit Possible cause: ventilator faulty, ventilation grille clogged User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 65 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system 7.2 Error codes for heater channel 1 Error Error description code 100 to Incorrect heater data 102 103 Checksum of the device data is incorrect 104 Software overtemperature 105 7.3 Electronic overtemperature Comments The measured temperature is more than 1.0°C over the set value temperature for this heater. An overtemperature protection facility which is independent of the software and which cuts out the heater if the temperature rises to an excessive value. Error codes for heater channel 2 Error Error description code 200 to Incorrect heater data 202 203 Checksum of the device data is incorrect 204 Software overtemperature 205 66 Error messages Electronic overtemperature Comments The measured temperature is more than 1.0°C over the set value temperature for this heater. An overtemperature protection facility which is independent of the software and which cuts out the heater if the temperature rises to an excessive value. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de Warranty and disclaimer 8 User manual Barkey XPT heating system Warranty and disclaimer Because Barkey GmbH & Co. KG has no control whatsoever over the quality of servicing work that is not carried out by Barkey personnel, and because Barkey GmbH & Co. KG cannot evaluate the effects which such servicing and repairs might have on the device and its serviceability, Barkey GmbH & Co. KG cannot accept any liability for damage to property, personal injury or consequential losses arising out of the use of a device which has not been repaired or serviced by Barkey service personnel. Barkey GmbH & Co. KG categorically declines all responsibility whatsoever for indirect damages or consequential damages of any type, and restricts its liabilities exclusively to repair or replacement of the device. Barkey GmbH & Co. KG grants this warranty in place of contractually or legally required warranties on this product, including other statutory guarantees of marketability or suitability for a particular use, and accepts no other liabilities. Barkey GmbH & Co. KG accepts no responsibility or liability whatsoever for the use of accessories other than those indicated in this User manual, for the use of non-original components or for any use/installation which does not conform to the User manual accompanying such components. The use of other components and accessories than those listed in the user manual leads to a reduction of the manufacturer's warranty for the device. Barkey GmbH & Co. KG only holds itself responsible for effects on the safety, reliability and performance of the device when extensions, resettings, modifications or repairs are carried out by persons it has authorised, and technical safety inspections have been demonstrably carried out by suitable specialist personnel at the prescribed intervals, and electrical installation has been carried out in accordance with German VDE stipulations or similar, and the device is used in accordance with this User manual, and the electrical safety has been demonstrably checked and tested according to the applicable regulations and at the prescribed intervals. WARNING Barkey GmbH & Co. KG accepts no liability for alterations carried out without authorisation or overhaul to the devices carried out by the customer or nonauthorised third parties. We recommend that you have any necessary repairs and regular maintenance carried out by Barkey GmbH & Co. KG or that you ensure your specialist personnel are trained at our special product training sessions with regard to inspection and maintenance. User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 67 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system 9 Customer Service Customer Service Barkey heating system XPT devices operate to a very large extent maintenance-free and are reliable. Should a repair be necessary despite our careful choice of components and high quality of manufacture, please note: Please return faulty devices for recycling repair to Barkey GmbH & Co. KG. Barkey GmbH & Co. KG will ensure that materials are properly separated, sorted and disposed of. We recommend that you have any necessary repairs and regular maintenance carried out by Barkey GmbH & Co. KG or that you ensure your specialist personnel are trained at our special product training sessions with regard to inspection and maintenance. The manufacturer and/or its subsidiary companies can supply upon request and against payment of a nominal charge a service manual containing all necessary circuit diagrams, parts lists, test instructions and service information enabling appropriately trained and qualified personnel to repair all those parts of the device which the manufacturer regards as repairable. If the device cannot be repaired or serviced on site, it must be returned. Please note the following rules before dispatching the device: Send the defective device for recycling and repair only to Barkey GmbH & Co. KG or its authorised distributors. The device must be cleaned and if necessary disinfected before it is dispatched. The returned device must not pose any kind of health risk, e.g. as a result of toxic, carcinogenic, biohazardous or radioactive substances. The sender shall be held liable for any losses caused by inadequate cleaning and disinfection. . Each returned device must be accompanied by a formal certificate of cleaning. Forms for this purpose are obtainable from Barkey GmbH & Co. KG on request. For safety reasons, devices which have not been cleaned or which are not accompanied by a certificate of cleaning will be returned to sender without being examined or repaired. Please follow the cleaning and disinfection procedures described in this user manual / operator manual. Please send a brief description of the fault along with the device. This will save you the cost of expensive fault diagnosis. Please pack the device for dispatch to Barkey GmbH & Co. KG so that it cannot be damaged in transit. Barkey GmbH & Co. KG can accept no liability for damage in transit due to inadequate packing. The Barkey GmbH & Co. KG customer service department is available Monday to Friday Saturday and Sunday on the following telephone number e-mail: 68 07:00 - 20:00 10:00 - 18:00 +49(0)5202- 9801-30. info@barkey.de User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Factory settings for temperature NOTE Barkey GmbH & Co. KG accepts no liability for modifications or repairs to the devices carried out by the user or by unauthorised third parties without consulting the supplier. Our conditions for repair and assembly and our warranty conditions are applicable. Our supply is subject to the general supply conditions for products and services of the electrical industry. 10 Factory settings for temperature The various Barkey heating system XPT heaters have the following factory settings and adjustment ranges: max. temperature Default value Barkey autoline XPT 4R 37°C Barkey autoline XPT 4R Heater Adjustment range Minimum Maximum 37,0°C 33,0°C 37,0°C 40°C 37,0°C 33,0°C 40,0°C Barkey autoline XPT 4R 41°C 37,0°C 33,0°C 41,0°C Barkey autoline XPT 4R 43°C 41,0°C 33,0°C 43,0°C Barkey autotherm XPT 41°C 38,5°C 33,0°C 41,0°C User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 69 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Specifications 11 Specifications 11.1 Barkey autocontrol 3XPT Manufacturer 70 Type Terminal Barkey GmbH & Co. KG Gewerbestrasse 8 33818 Leopoldshoehe Germany Tel.: +49(0)5202-9801-0 Fax: +49(0)5202-9801-99 Barkey autocontrol 3XPT 230 VAC / 115 VAC Mains frequency 50 – 60 Hz Power consumption max. 200 watts Current consumption 0.9 A at 230 VAC 1.75 A at 115 VAC Fusing 1 A slow-blow at 230 VAC 2 A slow-blow at 115 VAC Battery type lithium battery CR 1225, 3 V Outputs for two XPT heaters from the Barkey range each 24 Volt DC / max. 65 W Overtempere protection software-controlled: electronic: Temperature setting selectable from +33 °C to max. +43 °C (depending on the heater) Default setting +37 °C, 38.5 °C, 41 °C (depending on the heater) Control accuracy ± 0.5 ℃ set value + 1 °C 43.5 °C ± 1.5 ℃ 45.5 °C ± 1.5 °C for autoline Operation Storage/Transport Ambient temperature +10 to +40 °C -20 to +70 ℃ Relative atmospheric humidity (non-condensing) 30 to 75 % 30 to 90 % Air pressure 700 to 1060 hPa Operation type Continuous operation Dimensions Weight 140 x 210 x 130 mm (W x H x D mm) approx. 3.7 kg Safety class II double insulated Degree of protection CF, defibrillation proof MDD classification II b Moisture protection IP X1 Certification CE 0123 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system Specifications 11.2 Barkey autoline XPT 4R Manufacturer Type Barkey GmbH & Co. KG Gewerbestrasse 8 33818 Leopoldshoehe Germany Tel.: +49(0)5202-9801-0 Fax: +49(0)5202-9801-99 Barkey autoline XPT 4R Terminal 24 Volt DC Power consumption 60 watts Overtemperature protection software-controlled: electronic: Temperature setting selectable from +33°C to max. +37, 40, 41 or 43°C in 0.5°C – steps Default setting +37 or 41°C Sollwert + 1°C 45.5℃ ± 1.5℃ according to max. temp. as described in chapter 10 Control accuracy ± 0.5°C Warming time (from 20°C to 37°C) ca. 10 Min. (under conditions of moderate thermal dissipation) Operation Storage/Transport Ambient temperature +10 to +40°C -20 to +70℃ Relative atmospheric humidity (non-condensing) 30 to 75 % 30 to 90 % Air pressure 700 to 1060 hPa Operation type Continuous operation Dimensions (L x internal Ø) 2 variants: Weight approx. 0.3 kg Connection cord 2m 150 cm x Ø 4.3 mm 150 cm x Ø 6.0 mm In combination with the Barkey autocontrol 3XPT control unit: Safety class II double insulated Degree of protection CF, defibrillation proof MDD classification II b Moisture protection IP X1 Certification CE 0123 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 71 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de User manual Barkey XPT heating system 11.3 Barkey autotherm XPT Manufacturer Specifications Type Barkey GmbH & Co. KG Gewerbestrasse 8 33818 Leopoldshoehe Germany Tel.: +49(0)5202-9801-0 Fax: +49(0)5202-9801-99 Barkey autotherm XPT Terminal 24 Volt DC Power consumption 60 watts Overtemperature protection software-controlled: electronic: Temperature setting selectable from +33 °C to max. +41 °C in 0.5 °C steps set value 1 °C 43.5 ℃ ± 1.5 ℃ Default setting +38.5 °C Control accuracy ± 0.5 ℃ Warm-up time (from 20°C auf 37°C) approx. 20 min. (under conditions of moderate thermal dissipation) Operation Storage/Transport Ambient temperature +10 to +40 °C -20 to +70 ℃ Relative atmospheric humidity 30 to 75 % 30 to 90 % (non-condensing) Air pressure 700 to 1060 hPa Operation type Continuous operation Dimensions (H x internal Ø) depending on the version Weight depending on the version Connection cord depending on the version In combination with the Barkey autocontrol 3XPT control unit: 72 Safety class II double insulated Degree of protection CF defibrillation proof MDD classification II b Moisture protection IP X1 Certification CE 0123 User manual Barkey XPT heating system - V5 GB - ac-200-EW-0000-07 - 2013-10-23 Barkey GmbH & Co. KG - Gewerbestrasse 8 - 33818 Leopoldshoehe - Germany - Switchboard: +49(0)5202-9801-0 Customer service: +49(0)5202-9801-30 Fax: +49(0)5202-9801-99 - e-mail: info@barkey.de Barkey heating system XPT device master data sheet. Device designation: __________________________________________ Serial numbers: __________________________________________ Inventory number: __________________________________________ Set-up location: __________________________________________ Commissioning: __________________________________________ Identification: 0123 Manufacturer: Barkey GmbH & Co. KG Gewerbestrasse 8 33818 Leopoldshoehe Germany Telephone: +49(0)5202-9801-0 Fax: +49(0)5202-9801-99 E-mail: info@barkey.de