ProStar Wiring Guide Star Workstation Control Galaxie Control Stand-alone Control ©Varian, Inc. 2001 - 2004 Printed in U.S.A. 03-914825-00:Rev. 6 Star Workstation Control Contents Pumps 210/215/218 220/230/240 SD-1 Detectors 310 320 325/335 330 340 345 350/352 363 3 X 3 X 4 X 6 X 4 5 6 X X X 7 X 7 8 X 8 9 X 9 10 X 10 11 X 11 12 13 14 15 X X X X 12 X 13 14 15 X 16 17 18 X 16 X 17 X 18 X X X 16 17 18 X X X X See Operation Manual AutoSampler 3 4 400 410 420/430 X X 3 500 510 701 704 WS 800 MIB 5 X 4 5 X 5 6 7 8 9 X 10 X X X X X X X X X X X X X 6 7 8 9 10 11 X 12 13 14 15 16 17 X 18 X X X X X See Operation Manual X X X 11 12 13 14 X 15 X X X X X X X X X X 2 Back connectors for ProStar 210/218 (to internal CIM) INTGR 1 HI INTGR 1 LOW INTGR 1 GRD CHASSI S GRD ANALOG OUT ANALOG OUT GRD 7725i ProStar 210/218 Star WS Control Pumps of ProStar 210/218 Pumps, 310 UV Detector, and 410 AutoSampler 1 2 9-Pin connectors comm1 3 comm2 AUX +5V AUX GND serial communication ribbon 03-935462-91 connected to comm1 or comm2 STOP D GRD HOLD D GRD TRANSFER D GRD GPIB Interface INJECT CPU D GRD MARK 1v Data system output 2AUFS 1mV Chart recorder Output D GRD 10V ProStar 701 10mV Peak sensing relay Relay 1 Device Address Relay 2 1 2 3 4 5 ProStar 310 UV Detector A-GND GND ANALOG PEAK +13VDC Connected to GPIB slot in the CPU using cable P/N 81839700-00 CHASSIS ADVANCE EVT MARK Syn Signal J10 ProStar 410 AutoSampler INJECT P2 cable RACK J9 P1 cable INPUTS Relay 4 OUTPUTS Relay 3 3 Star WS Control of ProStar 210/218 Pumps, 320 UV Detector, and 410 AutoSampler Back connectors for 210/218 for 210/218 (To internal CIM) 7725i INTGR 1 HI INTGR 1 LOW INTGR 1 GRD CHASSIS GRD ANALOG OUT ANALOG OUT GRD ProStar 210/218 Pumps 1 2 9-Pin connectors comm1 3 comm2 serial communication ribbon AUX +5V 03-935462-91 AUX GND connected to comm1 or comm2 STOP D GRD HOLD D GRD ProStar 320 UV Detector Back Plate TRANSFER D GRD REC HI CPU INJECT REC LOW D GRD MARK REC GRD D GRD ProStar 701 INT HI INIT LOW INIT GRD EXT WAVE HI 1 PN R007200141 ProStar 410 AutoSampler PEAK A-GND ANALOG +13VDC GND CHASSIS To Contact 1 of 210 / 218 back connector ADVANCE EVENT MARK D GRD To Contact 2 of 210/218 back connector EVT MARK AUTO ZERO 5 INJECT P2 cable 4 RACK P1 cable 3 INPUTS LOW LAMP ON/OFF 2 OUTPUTS EXT WAVE 4 Star WS Control of ProStar 210/218 Pumps, 320 UV Detector, and 430 AutoSampler with a 510 Mistral Oven Back connectors for 210/218 (To internal CIM) INTGR 1 HI INTGR 1 LOW INTGR 1 GRD CHASSIS GRD ANALOG OUT ANALOG OUT GRD 7725i ProStar 210/218 Pumps 1 2 comm1 comm2 serial communication ribbon 9-Pin connectors 3 AUX +5V serial communication ribbon AUX GND 03-935462-91 connected to comm1 or comm2 STOP D GRD HOLD D GRD ProStar 320 UV Detector Back Plate TRANSFER D GRD CPU REC HI INJECT REC LOW D GRD MARK REC GRD D GRD INT HI ProStar 701 INIT LOW COM PORT INIT GRD ANALOG A-GND GND 5 CHASSIS PEAK To Contact 1 of 210/218 back connector +13VDC EVENT MARK D GRD To Contact 2 of 210/218 back connector ADVANCE AUTO ZERO 4 EVT MARK LAMP ON/OFF 3 INJECT 510 Mistral Oven 2 RACK P6 INPUTS 1 INPUTS P4 MARKER RELAY PN R007200141 EXT WAVE LOW OUTPUTS EXT WAVE HI ProStar 430 AutoSampler 5 Star WS Control of ProStar 210/218 Pumps, 325 UV Detector, 701 Fraction Collector and 410 AutoSampler Back connectors for 210/218 (To internal CIM) 7725i INTGR 1 HI INTGR 1 LOW INTGR 1 GRD CHASSIS GRD ANALOG OUT ANALOG OUT GRD ProStar 210/218 Pumps 1 2 9-Pin connectors comm1 3 comm2 serial communication ribbon AUX +5V 03-935462-91 AUX GND STOP D GRD HOLD D GRD TRANSFER D GRD GPIB Interface CPU INJECT D GRD Ethernet Cable MARK ProStar 701 D GRD R007200141 ProStar 410 AutoSampler ADVANCE PEAK A-GND ANALOG EVT MARK +13VDC GND CHASSIS Analog Cable 110744200 Channel A or B 5 INJECT ProStar 325 4 RACK P2 cable 3 INPUTS P1 cable 2 OUTPUTS 1 6 Star WS Control of ProStar 210/218 Pumps, 330 PDA Detector, and 410 AutoSampler Back connectors for 210/218 (To internal CIM) 7725i ProStar 210/218 Pumps To Inject & ground of the 210/218 CIM back connector INTGR 1 HI INTGR 1 LOW INTGR 1 GRD CHASSIS GRD ANALOG OUT ANALOG OUT GRD START (+) 1 GROUND (-) 2 9-Pin connectors comm1 3 comm2 AUX +5V serial communication ribbon 03-935462-91 AUX GND STOP D GRD HOLD D GRD TRANSFER D GRD GPIB Interface INJECT CPU D GRD MARK D GRD D-line connectors p/n 03-935716-01 P1 cable P2 cable ProStar 330 PDA Detector ProStar 410 AutoSampler p/n 81-839700-00 7 Star WS Control of ProStar 210/218 Pumps, 335 PDA Detector, 701 Fraction Collector and 410 AutoSampler Back connectors for 210/218 (To internal CIM) 7725i INTGR 1 HI INTGR 1 LOW INTGR 1 GRD CHASSIS GRD ANALOG OUT ANALOG OUT GRD ProStar 210/218 Pumps 1 2 9-Pin connectors comm1 3 comm2 serial communication ribbon AUX +5 V 03-935462-91 AUX GND STOP D GRD HOLD D GRD TRANSFER D GRD GPIB Interface CPU INJECT D GRD Ethernet Cable ProStar 701 MARK D GRD R007200141 Pro Star 335 ADVANCE PEAK A-GND ANALOG EVT MARK +13VDC GND CHASSIS Analog Cable 10744200 Channel A or B 5 INJECT ProStar 410 AutoSampler 4 RACK P2 cable 3 INPUTS P1 cable 2 OUTPUTS 1 8 Star WS Control of ProStar 210/218 Pumps, 345 UV Detector, 800 MIB, and 410 AutoSampler Back connectors for 210/218 (To internal CIM) INTGR 1 HI INTGR 1 LOW INTGR 1 GRD CHASSIS GRD ANALOG OUT ANALOG OUT GRD 7725i ProStar 210/215 Pumps 1 2 serial communication ribbon comm1 9 -Pin connectors 3 comm2 03-935462-91 AUX +5V Ethernet Communication Crossover cable AUX GND 393320601 connected to comm1 or comm2 STOP D GRD HOLD 800 MIB D GRD TRANSFER Analog cable to 800MIB 0390793802 CPU .01 V F /S STOP D GRD GND INJECT RUN / START GND .10 V F /S CH .1 .01 V F /S P2 cable ProStar 410 AutoSampler CH .2 MARK D GRD ZERO 1 .0 V F / S ANALOG GND P1 cable D GRD .10 V F /S GND GND GND NOT READY N.O. 1 .0 V F / S COMM ANALOG GND N.C. Note: In 6.2, both CIM can be activated and used for receiving analog signals, so the CH1 and 2 data can be input into INT hi & lo of the two available CIMs ProStar 345 Back Plate 9 Star WS Control of ProStar 210/218 Pumps, 363 Fluorescence Detector, and 410 AutoSampler Back connectors for 210/218 (To internal CIM) 7725i INTGR 1 HI INTGR 1 LOW INTGR 1 GRD CHASSIS GRD ANALOG OUT ANALOG OUT GRD ProStar 210/218 Pumps 1 2 9 - Pin connectors comm1 3 comm2 serial communication ribbon 03-935462-91 AUX +5V AUX GND connected to comm1 or comm2 STOP D GRD HOLD D GRD TRANSFER GPIB Interface D GRD 0393592201 INJECT CPU D GRD MARK PROCESSOR D GRD ProStar 701 RECORDER Fan READY/BUSY OUT ERROR OUT ProStar 410 AutoSampler ProStar 363 Fluorescence Detector PEAK +13VDC 4 5 ANALOG ADVANCE Can send data to 800 MIB using the cable PN 390793806 EVT MARK Serial out INJECT Power INPUTS P2 cable RACK P1 cable 3 OUTPUTS MARKER IN 2 CHASSIS 1 A-GND R007200141 LAMP OFF GND START IN AUTO ZERO OUT 10 Star WS Control of ProStar 210/218 Pumps, with 500 CVM, 320 UV Detector, and 410 AutoSampler Back connectors for 210/218 (internal CIM) 11 INTGR 1 500 CVM HI INTGR 1 LOW INTGR 1 GRD CHASSIS GRD ANALOG OUT ANALOG OUT GRD ProStar 210/218 Pumps 1 2 9 - Pin connectors comm1 3 comm2 serial communication ribbon AUX +5V AUX GND 03-935462-91 connect to comm1 or comm2 STOP R S 4 2 2 D GRD HOLD D GRD ProStar 320 UV Detector Back Plate TRANSFER D GRD REC HI INJECT REC LOW CPU D GRD MARK REC GRD D GRD ProStar 701 INT HI INIT LOW 11 5 ANALOG CHASSIS PEAK +13VDC ProStar 410 AutoSampler 4 A-GND ADVANCE To Contact 2 of 210/ 218 back connector EVT MARK EVENT MARK D GRD INJECT AUTO ZERO 3 RACK P2 cable 2 INPUTS LAMP ON/OFF P1 cable 1 PN R007200141 OUTPUTS EXT WAVE HI EXT WAVE LOW GND INIT GRD Star WS Control of ProStar 230 Pump, 310 UV Detector, and 410 AutoSampler ProStar 230 Pump Position sensing switch of Rheodyne manual injector is connected to Start In comm1 1v Data system output 2AUFS 1mV Chart recorder Output Start In Start In + Ready In Ready In + J9 Fault In Fault In + Gnd Gnd Start Out Start Out + Ready Out Ready Out + J10 Fault Out Fault Out + Ready In enable +5V comm2 10V (switch) 10mV (switch) Peak sensing relay Relay 1 Device Address Relay 2 Relay 3 Relay 4 J9 Syn Signal J10 GPIB cable PN 81-839700-00 - connect to comm1 or comm2 serial communication ribbon 03-935462-91 GPIB Interface CPU 1v Data system output 2AUFS 1mV Chart recorder Output 10V ProStar 701 10mV Peak sensing relay Relay 1 4 5 ANALOG CHASSIS 2 A-GND 1 GND Device Address Relay 2 3 ADVANCE PEAK EVT MARK +13VDC Syn Signal J10 ProStar 410 AutoSampler INJECT P2 cable INPUTS J9 P1 cable RACK Relay 4 OUTPUTS Relay 3 ProStar 310 UV Detector Connected to GPIB slot in the CPU using cable PN 81-839700-00 12 Star WS Control of ProStar 230 Pump, 320 UV Detector, 800 MIB, and 410 AutoSampler comm1 ProStar 230 Pump Position sensing switch of Rheodyne manual injector is connected to Start In 1v Data system output 2AUFS 1mV Chart recorder Output Start In Start In + Ready In Ready In + J9 Fault In Fault In + Gnd Gnd Start Out Start Out + Ready Out Ready Out + J10 Fault Out Fault Out + Ready In enable +5V comm2 10V (switch) 10mV (switch) Peak sensing relay Relay 1 Device Address Relay 2 Relay 3 Relay 4 J9 Syn Signal J10 GPIB cable P/N 81-839700-00 Ethernet Communication Crossover Cable connect to comm1 or comm2 p /n 393320601 800 MIB Analog Cable 390793802 REC HI GPIB Interface REC LOW CPU serial communication ribbon 03-935462-91 REC GRD INT HI ProStar 701 INIT LOW INIT GRD EXT WAVE HI ProStar 410 AutoSampler PEAK A-GND +13VDC GND 5 ANALOG ADVANCE D GRD EVT MARK EVENT MARK INJECT P2 cable 4 INPUTS P1 cable NOTE: Lamp ON/OFF, autozero can be connected to Relay 2 & 3 respectively of the 230 pump using the cable P/N 02-001594-00. 3 RACK AUTO ZERO 2 OUTPUTS 1 LAMP ON/OFF CHASSIS EXT WAVE LOW ProStar 320 UV Detector back plate 13 Star WS Control of ProStar 230 Pump, 330 PDA Detector, 410 AutoSampler and 701 Fraction Collector ProStar 230 Pump Position sensing switch of Rheodyne manual injector is connected to Start In Start In Start In + Ready In Ready In + J9 Fault In Fault In + Gnd Gnd Start Out Start Out + Ready Out Ready Out + J10 Fault Out Fault Out + Ready In enable +5V comm2 10V (switch) 10mV (switch) Peak sensing relay Relay 1 Device Address Relay 2 Relay 3 Relay 4 J9 Syn Signal J10 GPIB cable P/N 81-839700-00 connect to comm1 or comm2 D-line Connectors use cable p/n 0393571701 serial communication ribbon GPIB Interface 2 at address 1 03-935462-91 GPIB Interface 1 at address 0 CPU ProStar 330 ProStar 410 AutoSampler ANALOG PEAK +13VDC 5 CHASSIS ADVANCE EVT MARK 4 A-GND INJECT P2 cable Connected to GPIB slot in the CPU using cable P/N 81839700-00 3 RACK P1 cable 2 INPUTS 1 Analog I/O board p/n 0393592191 GND ProStar 701 OUTPUTS comm1 1v Data system output 2AUFS 1mV Chart recorder Output 14 Star WS Control of ProStar 230 Pump, 363 Fluorescence Detector, 800 MIB, and 410 AutoSampler comm1 ProStar 230 Pump Position sensing switch of Rheodyne manual injector is connected to Start In 1v Data system output 2AUFS 1mV Chart recorder Output Start In Start In + Ready In Ready In + J9 Fault In Fault In + Gnd Gnd Start Out Start Out + Ready Out Ready Out + J10 Fault Out Fault Out + Ready In enable +5V comm2 10V (switch) 10mV (switch) Peak sensing relay Relay 1 Device Address Relay 2 Relay 3 Relay 4 J9 Syn Signal J10 PN 81-839700-00 GPIB cable Ethernet Communication Crossover Cable 393320601 connect to comm1 or comm2 800 MIB serial communication ribbon 03-935462-91 Analog Cable for 363 only 390793806 GPIB Interface CPU PROCESSOR RECORDER ProStar 701 READY/BUSY OUT Fan ERROR OUT ADVANCE PEAK EVT MARK +13VDC Power ProStar 410 AutoSampler Serial out 5 ANALOG INJECT P2 cable 4 CHASSIS INPUTS RACK P1 cable 3 OUTPUTS MARKER IN 2 A-GND 1 LAMP OFF GND START IN AUTO ZERO OUT ProStar 363 Fluorescence Detector 15 Back connectors for SD-1 (To internal CIM) Back Connector 7725i ProStar SD-1 Star WS Control of Pumps PrepStar SD-1 Pumps, 320 UV Detector, and 410 AutoSampler TB 3 RELAY PUTPUT TB 2 DIGITAL INPUT TB1 ANALOG INTGR 1 HI STOP D GRD INTGR 1 LOW INTGR 1 GRD CHASSIS GRD TRANSFER INTGR 2 HI D GRD HOLD 9-Pin connectors comm2 INTGR 2 LOW INTGR 2 GRD CHASSIS GRD CHASSIS GRD ANALOG OUT D GRD serial communication ribbon INJECT D GRD 03-935462-91 connected to comm1 or comm2 MARK D GRD ANALOG OUT GRD CHASSIS GRD AUX +5V CHASSIS GRD ProStar 320 UV Detector Back Plate REC HI CPU REC LOW REC GRD ProStar 701 INT HI INIT LOW INIT GRD PEAK A-GND +13VDC GND To Contact 1 of SD-1 back connector ADVANCE EVENT MARK To Contact 2 of SD-1 back connector EVT MARK AUTO ZERO 4 INJECT P2 cable 3 RACK P1 cable 2 INPUTS LAMP ON/OFF 1 5 ANALOG PN R007200141 EXT WAVE LOW OUTPUTS EXT WAVE HI CHASSIS comm1 D GRD ProStar 410 AutoSampler 16 Star WS Control of PrepStar SD-1 Pumps, 500 CMV, 320 UV Detector, and 410 AutoSampler Back connectors for SD-1 (To internal CIM) 500 CVM Back Connector ProStar SD-1 Pumps TB 3 RELAY PUTPUT TB 2 DIGITAL INPUT TB1 ANALOG INTGR 1 HI STOP D GRD INTGR 1 LOW INTGR 1 GRD CHASSIS GRD TRANSFER INTGR 2 HI D GRD HOLD 9-Pin connectors comm1 comm2 serial communication ribbon connected to comm1 or comm2 D GRD INTGR 2 LOW INJECT INTGR 2 GRD MARK CHASSIS S GRD CHASSIS GRD D GRD ANALOG OUT AUX +5V CHASSIS GRD ANALOG OUT GRD CHASSIS GRD D GRD 03-935462-91 Pro Star 320 UV Detector Back Plate REC HI REC LOW CPU REC GRD ProStar 701 INT HI INIT LOW INIT GRD ProStar 410 AutoSampler ADVANCE PEAK A-GND ANALOG +13VDC GND CHASSIS To Contact 2 of SD-1 back connector 5 EVT MARK EVENT MARK 4 INJECT AUTO ZERO 3 RACK P2 cable 2 INPUTS LAMP ON/OFF P1 cable 1 PN R007200141 OUTPUTS EXT WAVE HI EXT WAVE LOW D GRD 17 Star WS Control of PrepStar SD-1 Pumps, 320 UV Detector, 430 AutoSampler and 510 Mistral Oven Back connectors for SD-1 (To internal CIM) Back Connector 7725i Model SD-1 Pumps TB 3 RELAY PUTPUT TB 2 DIGITAL INPUT TB1 ANALOG D GRD INTGR 1 HI INTGR 1 LOW INTGR 1 GRD CHASSIS GRD TRANSFER INTGR 2 HI STOP D GRD HOLD serial communication ribbon comm1 9-Pin connectors comm2 INTGR 2 LOW INTGR 2 GRD D GRD serial communication ribbon INJECT CHASSIS GRD CHASSIS GRD ANALOG OUT ANALOG OUT GRD CHASSIS GRD D GRD 03-935462-91 MARK connected to COMM1 D GRD AUX +5V CHASSIS GRD ProStar 320 UV Detector Back Plate REC HI ProStar 430 AutoSampler REC LOW CPU REC GRD INT HI ProStar 701 INIT LOW INIT GRD A-GND GND 5 ANALOG PEAK +13VDC To Contact 1 of SD - 1 back connector ADVANCE EVENT MARK - 1 To Contact 2 of SD back connector 4 EVT MARK AUTO ZERO 3 INJECT P6 INPUTS LAMP ON/OFF 2 RACK P4 MARKER RELAY Mistral ProStar 510 Oven 1 CHASSIS PN R007200141 EXT WAVE LOW INPUTS EXT WAVE HI OUTPUTS COM PORT D GRD 18 Galaxie Control Contents Pumps 20 210/215/218 220/230/240 SD-1 X Detectors 20 310 320 325/335 330 340 345 350/352 363 X 21 X X 21 22 X X 23 X 23 24 X 24 25 26 27 28 X X X X 25 26 27 28 X X X X See Operation Manual AutoSampler 20 21 400 410 420/430 X X X 24 25 26 27 28 X X X X X X 4 5 6 7 8 9 X X X X See Operation Manual X X X X X X X X X X X 2 X 22 X 23 1 500 510 701 704 WS 800 MIB 22 X 3 X X 19 Galaxie CDS Control through 800 MIB of ProStar 210/218 Pumps, 310 UV Detector, and 410 AutoSampler Back connectors for ProStar 210/218 (to internal CIM) INTGR 1 HI INTGR 1 LOW INTGR 1 GRD CHASSI S GRD ANALOG OUT ANALOG OUT GRD 7725i ProStar 210/218 Pumps 1 2 9-Pin connectors 3 AUX +5V AUX GND serial communication ribbon 03-935462-91 800 MIB STOP D GRD Network HOLD D GRD TRANSFER 03-907938-14 Serial Cable RJ45 to 9 Pin D GRD INJECT D GRD MARK 1v Data system output 2AUFS 1mV Chart recorder Output D GRD 10V ProStar 701 10mV Peak sensing relay Relay 1 Device Address Relay 2 1 2 3 4 5 PEAK A-GND +13VDC GND P2 cable ProStar 410 AutoSampler J10 ProStar 310 UV Detector Connected to GPIB slot in the CPU using cable P/N 81839700-00 ANALOG ADVANCE EVT MARK Syn Signal P1 cable CHASSIS INJECT RACK J9 INPUTS Relay 4 OUTPUTS Relay 3 20 Galaxie CDS Control through 800 MIB of ProStar 210/218 Pumps, 320 UV Detector, 410 AutoSampler, and 701 FC Back connectors for 210/218 for 210/218 (To internal CIM) 7725i INTGR 1 HI INTGR 1 LOW INTGR 1 GRD CHASSIS GRD ANALOG OUT ANALOG OUT GRD ProStar 210/218 Pumps 1 2 9-Pin connectors 3 serial communication ribbon AUX +5V 03-935462-91 AUX GND 800 MIB Network STOP D GRD Connect to comm 1, 2, 3 or 4 HOLD D GRD 03-907938-14 ProStar 320 UV Detector Back Plate TRANSFER D GRD REC HI INJECT REC LOW D GRD MARK REC GRD D GRD ProStar 701 INT HI INIT LOW ProStar 410 AutoSampler 21 PEAK +13VDC 4 5 ANALOG ADVANCE To Contact 1 of 210 / 218 back connector EVT MARK EVENT MARK D GRD To Contact 2 of 210/218 back connector INJECT AUTO ZERO INPUTS P2 cable RACK P1 cable 3 OUTPUTS LOW LAMP ON/OFF 2 CHASSIS 1 PN R007200141 A-GND EXT WAVE HI EXT WAVE GND INIT GRD Galaxie CDS Control through 800 MIB of ProStar 210/218 Pumps, 320 UV Detector, and 430 AutoSampler with a 510 Mistral Oven Back connectors for 210/218 (To internal CIM) INTGR 1 HI INTGR 1 LOW INTGR 1 GRD CHASSIS GRD ANALOG OUT ANALOG OUT GRD 7725i ProStar 210/218 Pumps 1 2 800 MIB serial communication ribbon 9-Pin connectors 3 Network Connect to comm 1, 2, 3 or 4 connected to comm1 or comm2 AUX +5V serial communication ribbon 03 935462 91 - AUX GND STOP 03-907938-14 D GRD HOLD D GRD ProStar 320 UV Detector Back Plate TRANSFER D GRD REC HI INJECT REC LOW D GRD MARK REC GRD D GRD INT HI ProStar 701 INIT LOW COM PORT ProStar 430 AutoSampler 22 4 5 A-GND ANALOG CHASSIS PEAK To Contact 1 of 210/218 back connector +13VDC EVENT MARK D GRD To Contact 2 of 210/218 back connector ADVANCE AUTO ZERO 3 EVT MARK LAMP ON/OFF 2 INJECT 510 Mistral Oven 1 INPUTS P6 INPUTS EXT WAVE LOW RACK P4 MARKER RELAY PN R007200141 OUTPUTS EXT WAVE HI GND INIT GRD Galaxie CDS Control through 800 MIB of ProStar 210/218 Pumps, 345 UV Detector, and 410 AutoSampler INTGR 1 HI INTGR 1 LOW INTGR 1 GRD CHASSIS GRD ANALOG OUT ANALOG OUT GRD 7725i ProStar 210/215 Pumps 1 2 serial communication ribbon 9 -Pin connectors 3 03-935462-91 AUX +5V AUX GND 03-907938-14 STOP D GRD HOLD D GRD 800 MIB TRANSFER STOP Analog cable to 800MIB 0390793802 .01 V F /S GND RUN / START GND .10 V F /S CH .1 .01 V F /S P2 cable ProStar 410 AutoSampler CH .2 D GRD MARK D GRD ZERO 1 .0 V F / S ANALOG GND P1 cable D GRD INJECT .10 V F /S GND GND GND NOT READY N.O. 1 .0 V F / S COMM ANALOG GND N.C. 23 ProStar 345 Back Plate Galaxie CDS Control through 800 MIB of ProStar 210/218 Pumps, 363 Fluorescence Detector, and 410 AutoSampler 7725i ProStar 210/218 Pumps 9 - Pin connectors serial communication ribbon 03-935462-91 800 MIB STOP Connect to comm 1, 2, 3 or 4 D GRD HOLD D GRD TRANSFER 03-907938-14 D GRD INJECT 03-907938-06 D GRD MARK PROCESSOR D GRD ProStar 701 RECORDER Fan READY/BUSY OUT ERROR OUT ProStar 410 AutoSampler Serial out ProStar 363 Fluorescence Detector ANALOG ADVANCE EVT MARK Power 5 CHASSIS INJECT P2 cable 4 A-GND INPUTS P1 cable RACK MARKER IN 2 GND 1 PEAK R007200141 LAMP OFF +13VDC START IN AUTO ZERO OUT OUTPUTS Network AUX +5V AUX GND 3 24 Galaxie CDS Control through 800 MIB of ProStar 230 Pump, 310 UV Detector and 410 AutoSampler ProStar 230 Pump Position sensing switch of Rheodyne manual injector is connected to Start In 1v Data system output 2AUFS 1mV Chart recorder Output Start In Start In + Ready In Ready In + J9 Fault In Fault In + Gnd Gnd Start Out Start Out + Ready Out Ready Out + J10 Fault Out Fault Out + Ready In enable +5V 10mV (switch) Peak sensing relay Relay 1 Device Address Relay 2 Relay 3 Relay 4 J9 Syn Signal J10 GPIB Cable Extender 81-839794-00 GPIB cable PN 81-839700-00 - 800 MIB Connect to comm 1, 2, 3 or 4 serial communication ribbon 03-935462-91 03-907938-14 1v Data system output 2AUFS 1mV Chart recorder Output 10V ProStar 701 10mV Peak sensing relay Relay 1 4 5 A-GND ANALOG GND CHASSIS 2 PEAK 1 +13VDC Device Address Relay 2 3 ADVANCE Syn Signal J10 ProStar 410 AutoSampler EVT MARK P2 cable INJECT J9 P1 cable INPUTS Relay 4 RACK Relay 3 OUTPUTS Network 10V (switch) ProStar 310 UV Detector Connected to GPIB slot in the CPU using cable PN 81-839700-00 25 Galaxie CDS Control through 800 MIB of ProStar 230 Pump, 320 UV Detector, and 410 AutoSampler Position sensing ProStar 230 Pump switch of Rheodyne manual injector is connected to Start In 1v Data system output 2AUFS 1mV Chart recorder Output Start In Start In + Ready In Ready In + J9 Fault In Fault In + Gnd Gnd Start Out Start Out + Ready Out Ready Out + J10 Fault Out Fault Out + Ready In enable +5V 10V (switch) 10mV (switch) Peak sensing relay Relay 1 Device Address Relay 2 Relay 3 Relay 4 J9 Syn Signal J10 GPIB Cable Extender 81-839704-00 800 MIB Network 03-907938-14 03-907938-14 serial communication ribbon 03-935462-91 Analog Cable 390793802 REC HI ProStar 701 REC LOW REC GRD INT HI INIT LOW P1 cable P2 cable INIT GRD EXT WAVE HI ADVANCE PEAK A-GND ANALOG EVT MARK +13VDC GND CHASSIS 5 INJECT EVENT MARK NOTE: Lamp ON /OFF, autozero can be connected to Relay 2 & 3 respectively of the 230 pump using the cable P/N 02-001594-00. 4 INPUTS AUTO ZERO 3 RACK LAMP ON/OFF 2 OUTPUTS ProStar 410 AutoSampler 1 EXT WAVE LOW D GRD ProStar 320 UV Detector back plate 26 Galaxie CDS Control through 800 MIB of ProStar 230 Pump, 325/335 PDA Detector, 410 AutoSampler and Fraction Collector ProStar 230 Pump Position sensing switch of Rheodyne manual injector is connected to Start In 1v Data system output 2AUFS 1mV Chart recorder Output Start In Start In + Ready In Ready In + J9 Fault In Fault In + Gnd Gnd Start Out Start Out + Ready Out Ready Out + J10 Fault Out Fault Out + Ready In enable +5V 10V (switch) 10mV (switch) Peak sensing relay Relay 1 Device Address Relay 2 Relay 3 Relay 4 J9 Syn Signal J10 (required for 335) Ethernet Acquistion Server GPIB Cable Extender 81-839704-00 GPIB cable P/N 81-839700-00 800 MIB Connect to comm 1, 2, 3 or 4 serial communication ribbon D-line Connectors use cable p/n 0393571701 03-935462-91 03-907938-14 Ethernet Switch Network ProStar 701 ADVANCE PEAK A-GND ANALOG EVT MARK +13VDC GND CHASSIS 5 INJECT ProStar 325/335 4 RACK P2 cable ProStar 410 AutoSampler 3 INPUTS P1 cable 2 OUTPUTS 1 27 Galaxie CDS Control of ProStar 230 Pump, 363 Fluorescence Detector, 800 MIB, and 410 AutoSampler ProStar 230 Pump Position sensing switch of Rheodyne manual injector is connected to Start In 1v Data system output 2AUFS 1mV Chart recorder Output Start In Start In + Ready In Ready In + J9 Fault In Fault In + Gnd Gnd Start Out Start Out + Ready Out Ready Out + J10 Fault Out Fault Out + Ready In enable +5V 10V (switch) 10mV (switch) Peak sensing relay Relay 1 Device Address Relay 2 Relay 3 Relay 4 J9 Syn Signal J10 PN 81-839700-00 GPIB cable 800 MIB Network serial communication ribbon 03-935462-91 Analog Cable for 363 only 390793806 PROCESSOR RECORDER ProStar 701 READY/BUSY OUT Fan ERROR OUT START IN 1 AUTO ZERO OUT ProStar 410 AutoSampler ADVANCE PEAK A-GND ANALOG EVT MARK +13VDC GND CHASSIS Serial out ProStar 363 Fluorescence Detector 5 INJECT P2 cable Power 4 RACK P1 cable 3 INPUTS MARKER IN 2 OUTPUTS LAMP OFF 28 Stand-alone Control Contents Pumps 30 210/215/218 220/230/240 31 32 33 34 X X X X X 35 36 37 38 39 40 41 X X X 35 36 42 43 44 45 X X X X X X X X 38 39 41 41 42 43 44 X X X X 46 X SD-1 Detectors 30 310 X 31 33 34 37 X X 320 32 X X X 45 46 X X 325/335 330 X 340 X 345 350/353 X X X 36 37 See Operation Manual 363 AutoSampler 30 31 33 34 35 X 400 410 32 X X X 420/430 X X 38 39 X X 41 41 42 43 44 45 46 X X X X X X X X X 30 31 32 33 34 35 36 37 38 39 41 41 42 43 44 45 46 X X X X X X X X X X X X X X X X X 500 510 701 704 See Operation Manual WS 800 MIB 29 ProStar 220/230/240 Pump (Master), 310 UV Detector, and 410 AutoSampler ProStar 220/230/240 Pump 1v 10V (switch) 1mV 10mV (switch) Data system output 2AUFS Start In Start In + Ready In Ready In + Fault In Fault In + Gnd Gnd Start Out Start Out + Ready Out Ready Out + Fault Out Fault Out + Ready In enable +5V Sync Cable Kit 03-91994890 Chart recorder Output J9 Peak sensing relay Relay 1 Device Address Relay 2 Relay 3 Relay 4 J10 J9 Syn Signal J10 Signal Cable 02-001954-00 Position sensing switch of Rheodyne manual injector is connected to Start In Start In Start In + Ready In Ready In + Fault In Fault In + Gnd Gnd Start Out Start Out + Ready Out Ready Out + Fault Out Fault Out + Ready In enable +5V Sync cable for ProStar 410 AutoSampler 0393516301 J9 1v Data system output 2AUFS J10 1mV Chart recorder Output 10V (switch) 10mV (switch) Peak sensing relay Relay 1 Relay 2 Device Address Relay 3 ProStar 701 Relay 4 J9 Clear +ve Syn Signal ADVANCE PEAK A-GND +13VDC GND 5 ANALOG 4 EVT MARK Detail CHASSIS ProStar 410 AutoSampler 3 INJECT P2 cable 2 RACK P1 cable 1 INPUTS ProStar 310 UV-Detector OUTPUTS J10 Black -ve 30 210/215/218 Pump (Master), 320 UV Detector, and 410 AutoSampler Extension cable R000815107 INTGR 1 HI INTGR 1 LOW INTGR 1 GRD CHASSIS GRD ANALOG OUT ANALOG OUT GRD AUX +5V 210/215/218 Pump Position sensing switch of Rheodyne manual injector is connected to Start In AUX GND STOP D GRD HOLD D GRD TRANSFER 1 D GRD INJECT 2 D GRD 3 MARK D GRD Shielded cable R007200141 REC HI REC LOW REC GRD INT HI INIT LOW ProStar 701 Shielded cable R007200141 INIT GRD EXT WAVE HI Shielded cable R007200141 ADVANCE PEAK A-GND +13VDC GND ProStar 320 UV-Detector EVT MARK D GRD INJECT P2 cable 4 INPUTS P1 cable NOTE: Lamp ON/OFF, autozero can be connected to Relay 2 & 3 respectively of the ProStar 220/230/240 pump using the cable 02-001594-00. 3 RACK AUTO ZERO EVENT MARK 2 OUTPUTS 1 LAMP ON/OFF 5 ANALOG EXT WAVE LOW Detail CHASSIS Sync cable for ProStar 410 AutoSamplers 0393516301 ProStar 410 AutoSampler 31 210/215/218 Pump (Master), 320 UV Detector, and 400 AutoSampler Extension cable R000815107 INTGR 1 HI INTGR 1 LOW INTGR 1 GRD CHASSIS GRD ANALOG OUT ANALOG OUT GRD AUX +5V 210/215/218 Pump Position sensing switch of Rheodyne manual injector is connected to Start In AUX GND STOP D GRD HOLD D GRD TRANSFER 1 D GRD INJECT 2 D GRD 3 MARK D GRD Shielded cable R007200141 REC HI REC LOW REC GRD INT HI INIT LOW ProStar 701 Shielded cable R007200141 INIT GRD EXT WAVE HI A-GND GND 5 ANALOG PEAK +13VDC ProStar 320 UV-Detector ADVANCE D GRD NOTE: Lamp ON/OFF, autozero can be connected to Relay 2 & 3 respectively of the ProStar 220/230/240 pump using the cable 02-001594-00. 4 EVT MARK EVENT MARK 3 INJECT AUTO ZERO 2 RACK 1 LAMP ON/OFF INPUTS CONTROL I/O OUTPUTS COMM PORT Shielded cable R007200141 EXT WAVE LOW Detail CHASSIS Sync cable for ProStar 400 AutoSamplers 0393516201 ProStar 400 AutoSampler 32 210/215/218 Pump (Master), 320 UV Detector, and 420/430 AutoSampler Extension cable R000815107 INTGR 1 HI INTGR 1 LOW INTGR 1 GRD CHASSIS GRD ANALOG OUT ANALOG OUT GRD AUX +5V 210/215/218 Pump Position sensing switch of Rheodyne manual injector is connected to Start In AUX GND STOP D GRD HOLD D GRD TRANSFER 1 D GRD INJECT 2 D GRD 3 MARK D GRD Shielded cable R007200141 Sync cable for ProStar 420/430 AutoSamplers 0393516101 REC HI REC LOW REC GRD INT HI INIT LOW ProStar 701 INIT GRD Shielded cable R007200141 EXT WAVE HI 2 3 4 INPUTS INJECT ADVANCE PEAK A-GND EVT MARK +13VDC GND LAMP ON/OFF P6 INPUTS AUTO ZERO EVENT MARK D GRD ProStar 420/430 AutoSampler NOTE: Lamp ON/OFF, autozero can be connected to Relay 2 & 3 respectively of the ProStar 220/230/240 pump using the cable 02-001594-00. ProStar 320 UV-Detector 5 Detail CHASSIS P4 MARKER RELAY ANALOG 1 RACK Shielded cable R007200141 EXT WAVE LOW OUTPUTS COM PORT 33 210/215/218 Pump (Master), 340 UV Detector, and 420/430 AutoSampler Extension cable R000815107 INTGR 1 HI INTGR 1 LOW INTGR 1 GRD CHASSIS GRD ANALOG OUT ANALOG OUT GRD 210/215/218 Pump Position sensing switch of Rheodyne manual injector is connected to Start In STOP D GRD HOLD D GRD TRANSFER 1 D GRD INJECT 2 NOTE: AUX +5V AUX GND D GRD Please refer to the other detector diagrams for connection with the other AutoSamplers 3 MARK D GRD Shielded cable R007200141 Shielded cable R007200141 + 1 - 2 + - 3 + 4 - EVENT + - 5 + - ProStar 701 Shielded cable R007200141 6 INPUTS INJECT ADVANCE PEAK EVT MARK +13VDC ProStar 340 UV-Detector 3 RACK P6 INPUTS 2 OUTPUTS 1 P4 MARKER RELAY 4 5 ANALOG COM PORT INT 1AU/V CHASSIS RECORDER REMOTE AUTO ZERO A-GND OUTPUT GND Sync cable for ProStar 420/430 AutoSampler 0393516101 Detail ProStar 420/430 AutoSampler 34 ProStar 220/230/240 Pump (Master), 340 UV Detector, and 410 AutoSampler ProStar 220/230/240 Pump Position sensing switch of Rheodyne manual injector is connected to Start In Start In Start In + Ready In Ready In + Fault In Fault In + Gnd Gnd Start Out Start Out + Ready Out Ready Out + Fault Out Fault Out + Ready In enable +5V 1v Data system output 2AUFS 1mV Chart recorder Output J9 10V (switch) 10mV (switch) Peak sensing relay Relay 1 Device Address Relay 2 Relay 3 Relay 4 J10 J9 Syn Signal J10 Shielded cable, R007200141 OUTPUT Sync cable for ProStar 410 AutoSampler 0393516301 RECORDER + 1 NOTE: - 2 Signal Cable 02-001954-00 REMOTE INT 1AU/V + - 3 AUTO ZERO + 4 - EVENT + - 5 + - 6 Please refer the appropriate diagram for connections to the other AutoSamplers Clear +ve INPUTS INJECT ADVANCE PEAK A-GND EVT MARK +13VDC GND To the appropriate Integrator 5 ANALOG 4 CHASSIS 3 Detail P2 cable ProStar 410 AutoSampler 2 RACK P1 cable 1 OUTPUTS ProStar 340 UV-Detector back plate Black +ve ProStar 701 35 ProStar 220/230/240 Pump (Master), 345 UV and 360 Fluorescence Detectors, and 410 AutoSampler ProStar 220/230/240 Pump Position sensing switch of Rheodyne manual injector is connected to Start In J9 10V (switch) 10mV (switch) Peak sensing relay Relay 1 Device Address Relay 2 Relay 3 Signal Cable 02-001954-00 Relay 4 J10 J9 Syn Signal J10 To the appropriate integrator Shielded cable R007200141 STOP .01 V F/S GND RUN/START .10 V F/S CH.1 GND Shielded cable R007200141 ANALOG GND ZERO NOTE: Please refer the appropriate diagram for connections to the other AutoSamplers 1.0 V F/S GND .01 V F/S GND CH.2 GND NOT READY N.O. .10 V F/S 1.0 V F/S ANALOG GND Clear +ve 1 INJECT ADVANCE PEAK A-GND EVT MARK +13VDC GND P2 cable 4 INPUTS P1 cable 3 RACK N.C. 2 OUTPUTS COMM 5 ANALOG Sync cable for ProStar 410 AutoSampler 0393516301 Signal Cable 02-001954-00 Detail ProStar 345/360 Detector ProStar 410 Autosampler CHASSIS Start In Start In + Ready In Ready In + Fault In Fault In + Gnd Gnd Start Out Start Out + Ready Out Ready Out + Fault Out Fault Out + Ready In enable +5V 1v Data system output 2AUFS 1mV Chart recorder Output Black +ve ProStar 701 36 210/215/218 Pump (Master), 345 UV & 360 Fluorescence Detectors, and 420/430 AutoSampler INTGR 1 HI INTGR 1 LOW INTGR 1 GRD CHASSIS GRD ANALOG OUT ANALOG OUT GRD Extension cable R000815107 210/215/218 Pump Position sensing switch of Rheodyne manual injector is connected to Start In HOLD TRANSFER D GRD INJECT 2 D GRD 3 MARK D GRD Shielded cable R007200141 .01 V F/S STOP GND .10 V F/S CH.1 ANALOG GND .01 V F/S 3 4 5 ANALOG Detail 2 CHASSIS N.O. 1 A-GND P6 INPUTS ANALOG GND GND NOT READY 1.0 V F/S PEAK GND .10 V F/S +13VDC CH.2 Shielded cable R007200141 ADVANCE GND ProStar 701 EVT MARK GND INJECT ZERO RACK GND COM PORT 1.0 V F/S INPUTS RUN/START Shielded cable R007200141 OUTPUTS Sync cable for ProStar 420/430 AutoSamplers 0393516101 P4 MARKER RELAY STOP D GRD D GRD 1 NOTE: Please refer to the other detector diagrams for connection with the other AutoSamplers AUX +5V AUX GND COMM N.C. ProStar 420/430 AutoSampler ProStar 345/360 Detector 37 ProStar 220/230/240 Pump (Master), 310 UV Detector, and 400 ProStar 220/230/240 Pump AutoSampler 1v 10V (switch) Data system output 2AUFS Start In Start In + Ready In Ready In + Fault In Fault In + Gnd Gnd Start Out Start Out + Ready Out Ready Out + Fault Out Fault Out + Ready In enable +5V Sync Cable Kit 03-91994890 1mV 10mV (switch) Chart recorder Output J9 Peak sensing relay Relay 1 Device Address Relay 2 Relay 3 Relay 4 J10 J9 Syn Signal J10 Signal Cable 02-001954-00 Position sensing switch of Rheodyne manual injector is connected to Start In Sync cable for ProStar 400 AutoSampler 0393516201 Start In Start In + Ready In Ready In + Fault In Fault In + Gnd Gnd Start Out Start Out + Ready Out Ready Out + Fault Out Fault Out + Ready In enable +5V J9 1v Data system output 2AUFS J10 1mV Chart recorder Output 10V (switch) 10mV (switch) Peak sensing relay Relay 1 Device Address Relay 2 Relay 3 ProStar 701 Relay 4 J9 Clear +ve Syn Signal 2 3 4 INPUTS INJECT ADVANCE PEAK A-GND RACK EVT MARK +13VDC GND CONTROL I/O ProStar 310 UV-Detector 5 ANALOG 1 OUTPUTS J10 COMM PORT CHASSIS Detail ProStar 400 AutoSampler Black -ve 38 ProStar 220/230/240 Pump (Master), 320 UV Detector, and 400 AutoSampler ProStar 220/230/240 Pump Position sensing switch of Rheodyne manual injector is connected to Start In 1v 10V (switch) 1mV 10mV (switch) Data system output 2AUFS Start In Start In + Ready In Ready In + Fault In Fault In + Gnd Gnd Start Out Start Out + Ready Out Ready Out + Fault Out Fault Out + Ready In enable +5V Chart recorder Output J9 Peak sensing relay Relay 1 Device Address Relay 2 Relay 3 Relay 4 J10 J9 Syn Signal J10 Signal Cable 02-001954-00 Sync cable for ProStar 400 AutoSampler 0393516201 REC HI REC LOW REC GRD INT HI INIT LOW ProStar 701 INIT GRD Clear +ve ProStar 320 UV-Detector back plate 4 PEAK A-GND GND 5 ANALOG 3 +13VDC ProStar 400 AutoSampler 2 ADVANCE EVENT MARK D GRD Detail 1 EVT MARK AUTO ZERO NOTE : Lamp ON/OFF, autozero can be connected to Relay 2 & 3 respectively of the ProStar 220/230/240 pump using the cable 02-001594-00. INJECT LAMP ON/OFF RACK EXT WAVE LOW INPUTS CONTROL I/O OUTPUTS COMM PORT CHASSIS EXT WAVE HI Black -ve 39 ProStar 220/230/240 Pump (Master), 320 UV Detector, and 420/430 AutoSampler Position sensing switch of Rheodyne manual injector is connected to Start In ProStar 220/230/240 Pump 1v Data system output 2AUFS Start In Start In + Ready In Ready In + Fault In Fault In + Gnd Gnd Start Out Start Out + Ready Out Ready Out + Fault Out Fault Out + Ready In enable +5V 1mV Chart recorder Output J9 10V (switch) 10mV (switch) Peak sensing relay Relay 1 Device Address Relay 2 Relay 3 Relay 4 J10 J9 Syn Signal J10 Signal Cable 02-001954-00 Sync cable for ProStar 420/430 AutoSampler 0393516101 REC HI REC LOW REC GRD INT HI ProStar 701 INIT LOW INIT GRD Clear +ve EXT WAVE LOW ProStar 320 UV-Detector back plate ADVANCE PEAK A-GND +13VDC GND D GRD 4 EVT MARK ProStar 420/430 AutoSampler Detail 3 INJECT EVENT MARK NOTE : Lamp ON/OFF, autozero can be connected to Relay 2 & 3 respectively of the ProStar 220/230/240 pump using the cable 02-001594-00. 2 RACK AUTO ZERO 1 INPUTS LAMP ON/OFF OUTPUTS P6 INPUTS 5 ANALOG EXT WAVE HI P4 MARKER RELAY CHASSIS COM PORT Black -ve 40 ProStar 220/230/240 Pump (Master), 310 UV Detector, and 420/430 AutoSampler ProStar 220/230/240 Pump 1v 10V (switch) Data system output 2AUFS 10mV (switch) Chart recorder Output J9 Peak sensing relay Relay 1 Device Address Relay 2 Relay 3 Relay 4 J10 J9 Syn Signal J10 Signal Cable 02-001954-00 Start In Start In + Ready In Ready In + J9 Fault In Fault In + Gnd Gnd Start Out Start Out + Ready Out Ready Out + J10 Fault Out Fault Out + Ready In enable +5V 1v 10V (switch) 1mV 10mV (switch) Data system output 2AUFS Chart recorder Output Peak sensing relay Relay 1 Relay 2 Device Address Relay 3 J9 Clear +ve Syn Signal 4 PEAK A-GND +13VDC GND Detail ProStar 420/430 AutoSampler 5 ANALOG 3 CHASSIS 2 ADVANCE P6 INPUTS 1 EVT MARK ProStar 310 UV-Detector INJECT J10 RACK Sync cable for ProStar 420/430 AutoSampler 0393516101 P4 MARKER RELAY ProStar 701 Relay 4 COM POR T INPUTS Position sensing switch of Rheodyne manual injector is connected to Start In OUTPUTS Sync Cable Kit 03-91994890 Start In Start In + Ready In Ready In + Fault In Fault In + Gnd Gnd Start Out Start Out + Ready Out Ready Out + Fault Out Fault Out + Ready In enable +5V 1mV Black -ve 41 210/215/218 Pump (Master), 310 UV Detector, and 400 AutoSampler INTGR HI INTGR LOW INTGR GRD CHASSIS GRD ANALOG OUT ANALOG OUT AUX +5V 210/215/218 Pump Position sensing switch of Rheodyne manual injector is connected to Start In Extension R000815107 AUX GND STOP D GND HOLD D GND TRANSFER 1 D GND INJECT 2 D GND 3 MARK D GND Shielded R007200141 CONTROL I/O 10V (switch) 10mV (switch) Chart recorder Output Peak Sensing relay Relay 1 Relay 2 Device Address Relay 3 ProStar 701 Shielded R007200141 Relay 4 J9 SyN Signal J10 INJECT ADVANCE PEAK A-GND EVT MARK +13VDC GND 4 RACK Detail ProStar 400 AutoSampler 3 INPUTS ProStarr 310 UV-Detector 2 OUTPUTS 1 5 ANALOG COMM PORT 1v 1mV Data system output 2AUFS CHASSIS Sync cable for ProStar 400 AutoSampler 0393516201 Start In Start In + Ready In Ready In + J9 Fault In Fault In + Gnd Gnd Start Out Start Out + Ready Out Ready Out + J10 Fault Out Fault Out + Ready In enable +5V Shielded R007200141 42 210/215/218 Pump (Master), 310 UV Detector, and 420/430 AutoSampler Extension cable R000815107 INTGR 1 HI INTGR 1 LOW INTGR 1 GRD CHASSIS GRD ANALOG OUT ANALOG OUT GRD AUX +5V 210/215/218 Pump AUX GND Position sensing switch of Rheodyne manual injector is connected to Start In STOP D GRD HOLD D GRD TRANSFER 1 D GRD INJECT 2 D GRD 3 MARK D GRD Shielded cable R007200141 Sync cable for ProStar 420/430 AutoSampler 0393516101 COM PORT Start In Start In + Ready In Ready In + Fault In Fault In + Gnd Gnd Start Out Start Out + Ready Out Ready Out + Fault Out Fault Out + Ready In enable +5V J9 J10 1v Data system output 2AUFS 1mV Chart recorder Output Shielded cable R007200141 10V (switch) 10mV (switch) Peak sensing relay Relay 1 Device Address Relay 2 ProStar 701 Relay 3 Shielded cable R007200141 Relay 4 J9 Syn Signal J10 ANALOG PEAK +13VDC CHASSIS ADVANCE EVT MARK 5 A-GND INJECT 4 GND INPUTS ProStar 310 UV-Detector 3 RACK P6 INPUTS 2 OUTPUTS 1 P4 MARKER RELAY Detail ProStar 420/430 AutoSampler 43 210/215/218 Pump (Master), 310 UV Detector, and 410 AutoSampler INTGR 1 HI INTGR 1 LOW INTGR 1 GRD CHASSIS GRD ANALOG OUT ANALOG OUT GRD Extension cable R000815107 AUX +5V Position sensing switch of Rheodyne manual injector is connected to Start In 210/215/218 Pump AUX GND STOP D GRD HOLD D GRD TRANSFER 1 D GRD INJECT 2 D GRD 3 MARK D GRD Shielded cable R007200141 Start In Start In + Ready In Ready In + J9 Fault In Fault In + Gnd Gnd Start Out Start Out + Ready Out Ready Out + J10 Fault Out Fault Out + Ready In enable +5V Sync cable for ProStar 410 AutoSamplers 0393516301 1v Data system output 2AUFS 1mV Chart recorder Output Shielded cable R007200141 10V (switch) 10mV (switch) Peak sensing relay Relay 1 Relay 2 Device Address Relay 3 ProStar 701 Shielded cable R007200141 Relay 4 Syn Signal J9 J10 ADVANCE PEAK A-GND ANALOG EVT MARK +13VDC GND CHASSIS 5 INJECT 4 RACK 3 INPUTS ProStar 310 UV-Detector 2 OUTPUTS 1 Detail P1 cable P2 cable ProStar 410 AutoSampler 44 210/215/218 Pump (Master), 340 UV Detector, and 420/430 AutoSampler Extension cable R000815107 INTGR 1 HI INTGR 1 LOW INTGR 1 GRD CHASSIS GRD ANALOG OUT ANALOG OUT GRD 210/215/218 Pump Position sensing switch of Rheodyne manual injector is connected to Start In STOP D GRD HOLD D GRD TRANSFER 1 D GRD INJECT 2 NOTE: AUX +5V AUX GND D GRD Please refer to the other detector diagrams for connection with the other AutoSamplers 3 MARK D GRD Shielded cable R007200141 Shielded cable R007200141 + 1 - 2 + - 3 + 4 - EVENT + - 5 + - ProStar 701 Shielded cable R007200141 6 INPUTS INJECT ADVANCE PEAK EVT MARK +13VDC ProStar 340 UV-Detector 3 RACK P6 INPUTS 2 OUTPUTS 1 P4 MARKER RELAY 4 5 ANALOG COM PORT AUTO ZERO CHASSIS RECORDER REMOTE INT 1AU/V A-GND OUTPUT GND Sync cable for ProStar 420/430 AutoSampler 0393516101 Detail ProStar 420/430 AutoSampler 45 ProStar 220/230/240 Pump (Master), 320 UV Detector, and 410 AutoSampler Position sensing switch of Rheodyne manual injector is connected to Start In ProStar 220/230/240 Pump 1v Data system output 2AUFS Start In Start In + Ready In Ready In + Fault In Fault In + Gnd Gnd Start Out Start Out + Ready Out Ready Out + Fault Out Fault Out + Ready In enable +5V 1mV Chart recorder Output J9 10V (switch) 10mV (switch) Peak sensing relay Relay 1 Device Address Relay 2 Relay 3 Relay 4 J10 J9 Syn Signal J10 Signal Cable 02-001954-00 Sync cable for ProStar 410 0393516301 REC HI REC LOW REC GRD INT HI ProStar 701 INIT LOW INIT GRD Clear +ve ProStar410 AutoSampler ProStar 320 UV-Detector back plate ADVANCE PEAK A-GND EVT MARK +13VDC GND D GRD 4 INJECT P2 cable Detail 3 INPUTS P1 cable EVENT MARK NOTE : Lamp ON/OFF, autozero can be connected to Relay 2 & 3 respectively of the ProStar 220/230/240 pump using the cable 02-001594-00. 2 RACK AUTO ZERO 1 OUTPUTS LAMP ON/OFF 5 ANALOG EXT WAVE LOW CHASSIS EXT WAVE HI Black -ve 46