ProStar
Wiring Guide
™ Star Workstation Control
™ Galaxie Control
™ Stand-alone Control
©Varian, Inc. 2001 - 2004
Printed in U.S.A.
03-914825-00:Rev. 6
Star Workstation Control Contents
Pumps
210/215/218
220/230/240
SD-1
Detectors
310
320
325/335
330
340
345
350/352
363
3
X
3
X
4
X
6
X
4
5
6
X
X
X
7
X
7
8
X
8
9
X
9
10
X
10
11
X
11
12
13
14
15
X
X
X
X
12
X
13
14
15
X
16
17
18
X
16
X
17
X
18
X
X
X
16
17
18
X
X
X
X
See Operation Manual
AutoSampler
3
4
400
410
420/430
X
X
3
500
510
701
704
WS
800 MIB
5
X
4
5
X
5
6
7
8
9
X
10
X
X
X
X
X
X
X
X
X
X
X
X
X
6
7
8
9
10
11
X
12
13
14
15
16
17
X
18
X
X
X
X
X
See Operation Manual
X
X
X
11
12
13
14
X
15
X
X
X
X
X
X
X
X
X
X
2
Back connectors for ProStar 210/218
(to internal CIM)
INTGR 1
HI
INTGR 1
LOW
INTGR 1
GRD
CHASSI
S GRD
ANALOG
OUT
ANALOG
OUT GRD
7725i
ProStar 210/218
Star WS Control
Pumps
of ProStar 210/218 Pumps,
310 UV Detector, and 410 AutoSampler
1
2
9-Pin connectors
comm1
3
comm2
AUX
+5V
AUX
GND
serial communication ribbon
03-935462-91
connected to
comm1 or
comm2
STOP
D GRD
HOLD
D GRD
TRANSFER
D GRD
GPIB Interface
INJECT
CPU
D GRD
MARK
1v
Data system
output 2AUFS
1mV
Chart recorder
Output
D GRD
10V
ProStar 701
10mV
Peak sensing relay
Relay 1
Device Address
Relay 2
1
2
3
4
5
ProStar 310 UV Detector
A-GND
GND
ANALOG
PEAK
+13VDC
Connected to GPIB
slot in the CPU using
cable P/N 81839700-00
CHASSIS
ADVANCE
EVT MARK
Syn Signal
J10
ProStar 410 AutoSampler
INJECT
P2 cable
RACK
J9
P1 cable
INPUTS
Relay 4
OUTPUTS
Relay 3
3
Star WS Control of ProStar 210/218 Pumps,
320 UV Detector, and 410 AutoSampler
Back connectors for 210/218
for 210/218
(To internal CIM)
7725i
INTGR 1
HI
INTGR 1
LOW
INTGR 1
GRD
CHASSIS
GRD
ANALOG
OUT
ANALOG
OUT GRD
ProStar 210/218
Pumps
1
2
9-Pin connectors
comm1
3
comm2
serial communication ribbon
AUX
+5V
03-935462-91
AUX
GND
connected to
comm1 or
comm2
STOP
D GRD
HOLD
D GRD
ProStar 320 UV
Detector Back Plate
TRANSFER
D GRD
REC HI
CPU
INJECT
REC
LOW
D GRD
MARK
REC
GRD
D GRD
ProStar 701
INT HI
INIT
LOW
INIT
GRD
EXT
WAVE HI
1
PN R007200141
ProStar 410 AutoSampler
PEAK
A-GND
ANALOG
+13VDC
GND
CHASSIS
To Contact 1 of 210 /
218 back connector
ADVANCE
EVENT
MARK
D GRD
To Contact 2 of 210/218
back connector
EVT MARK
AUTO
ZERO
5
INJECT
P2 cable
4
RACK
P1 cable
3
INPUTS
LOW
LAMP
ON/OFF
2
OUTPUTS
EXT WAVE
4
Star WS Control of
ProStar 210/218 Pumps,
320 UV Detector, and 430 AutoSampler
with a 510 Mistral Oven
Back connectors for 210/218
(To internal CIM)
INTGR 1
HI
INTGR 1
LOW
INTGR 1
GRD
CHASSIS
GRD
ANALOG
OUT
ANALOG
OUT GRD
7725i
ProStar 210/218
Pumps
1
2
comm1
comm2
serial communication
ribbon
9-Pin connectors
3
AUX
+5V
serial communication ribbon
AUX
GND
03-935462-91
connected to
comm1 or
comm2
STOP
D GRD
HOLD
D GRD
ProStar 320 UV
Detector Back Plate
TRANSFER
D GRD
CPU
REC HI
INJECT
REC
LOW
D GRD
MARK
REC
GRD
D GRD
INT HI
ProStar 701
INIT
LOW
COM
PORT
INIT
GRD
ANALOG
A-GND
GND
5
CHASSIS
PEAK
To Contact 1 of 210/218
back connector
+13VDC
EVENT
MARK
D GRD
To Contact 2 of 210/218
back connector
ADVANCE
AUTO
ZERO
4
EVT MARK
LAMP
ON/OFF
3
INJECT
510 Mistral
Oven
2
RACK
P6
INPUTS
1
INPUTS
P4
MARKER
RELAY
PN R007200141
EXT WAVE
LOW
OUTPUTS
EXT
WAVE HI
ProStar 430 AutoSampler
5
Star WS Control of
ProStar 210/218 Pumps,
325 UV Detector, 701 Fraction Collector
and 410 AutoSampler
Back connectors for 210/218
(To internal CIM)
7725i
INTGR 1
HI
INTGR 1
LOW
INTGR 1
GRD
CHASSIS
GRD
ANALOG
OUT
ANALOG
OUT GRD
ProStar 210/218
Pumps
1
2
9-Pin connectors
comm1
3
comm2
serial communication ribbon
AUX
+5V
03-935462-91
AUX
GND
STOP
D GRD
HOLD
D GRD
TRANSFER
D GRD
GPIB Interface
CPU
INJECT
D GRD
Ethernet
Cable
MARK
ProStar 701
D GRD
R007200141
ProStar 410 AutoSampler
ADVANCE
PEAK
A-GND
ANALOG
EVT MARK
+13VDC
GND
CHASSIS
Analog Cable 110744200
Channel A or B
5
INJECT
ProStar 325
4
RACK
P2 cable
3
INPUTS
P1 cable
2
OUTPUTS
1
6
Star WS Control of
ProStar 210/218 Pumps,
330 PDA Detector, and 410 AutoSampler
Back connectors for 210/218
(To internal CIM)
7725i
ProStar 210/218 Pumps
To Inject & ground
of the 210/218 CIM
back connector
INTGR 1
HI
INTGR 1
LOW
INTGR 1
GRD
CHASSIS
GRD
ANALOG
OUT
ANALOG
OUT GRD
START (+)
1
GROUND (-)
2
9-Pin connectors
comm1
3
comm2
AUX
+5V
serial communication ribbon
03-935462-91
AUX
GND
STOP
D GRD
HOLD
D GRD
TRANSFER
D GRD
GPIB Interface
INJECT
CPU
D GRD
MARK
D GRD
D-line
connectors
p/n 03-935716-01
P1 cable
P2 cable
ProStar 330 PDA Detector
ProStar 410 AutoSampler
p/n 81-839700-00
7
Star WS Control of
ProStar 210/218 Pumps, 335 PDA Detector,
701 Fraction Collector and
410 AutoSampler
Back connectors for 210/218
(To internal CIM)
7725i
INTGR 1
HI
INTGR 1
LOW
INTGR 1
GRD
CHASSIS
GRD
ANALOG
OUT
ANALOG
OUT GRD
ProStar 210/218 Pumps
1
2
9-Pin connectors
comm1
3
comm2
serial communication ribbon
AUX
+5 V
03-935462-91
AUX
GND
STOP
D GRD
HOLD
D GRD
TRANSFER
D GRD
GPIB Interface
CPU
INJECT
D GRD
Ethernet
Cable
ProStar 701
MARK
D GRD
R007200141
Pro Star 335
ADVANCE
PEAK
A-GND
ANALOG
EVT MARK
+13VDC
GND
CHASSIS
Analog Cable 10744200
Channel A or B
5
INJECT
ProStar 410
AutoSampler
4
RACK
P2 cable
3
INPUTS
P1 cable
2
OUTPUTS
1
8
Star WS Control of
ProStar 210/218 Pumps,
345 UV Detector, 800 MIB,
and 410 AutoSampler
Back connectors for 210/218
(To internal CIM)
INTGR 1
HI
INTGR 1
LOW
INTGR 1
GRD
CHASSIS
GRD
ANALOG
OUT
ANALOG
OUT GRD
7725i
ProStar 210/215 Pumps
1
2
serial communication ribbon
comm1
9 -Pin connectors
3
comm2
03-935462-91
AUX
+5V
Ethernet Communication
Crossover cable
AUX
GND
393320601
connected to
comm1 or
comm2
STOP
D GRD
HOLD
800 MIB
D GRD
TRANSFER
Analog cable to 800MIB
0390793802
CPU
.01 V F /S
STOP
D GRD
GND
INJECT
RUN /
START
GND
.10 V F /S
CH .1
.01 V F /S
P2 cable
ProStar 410 AutoSampler
CH .2
MARK
D GRD
ZERO
1 .0 V F / S
ANALOG
GND
P1 cable
D GRD
.10 V F /S
GND
GND
GND
NOT
READY
N.O.
1 .0 V F / S
COMM
ANALOG
GND
N.C.
Note: In 6.2, both CIM can be
activated and used for receiving
analog signals, so the CH1 and 2 data
can be input into INT hi & lo of the two
available CIMs
ProStar 345 Back Plate
9
Star WS Control of
ProStar 210/218 Pumps,
363 Fluorescence Detector, and
410 AutoSampler
Back connectors for 210/218
(To internal CIM)
7725i
INTGR 1
HI
INTGR 1
LOW
INTGR 1
GRD
CHASSIS
GRD
ANALOG
OUT
ANALOG
OUT GRD
ProStar 210/218
Pumps
1
2
9 - Pin connectors
comm1
3
comm2
serial communication ribbon
03-935462-91
AUX
+5V
AUX
GND
connected to
comm1 or
comm2
STOP
D GRD
HOLD
D GRD
TRANSFER
GPIB Interface
D GRD
0393592201
INJECT
CPU
D GRD
MARK
PROCESSOR
D GRD
ProStar 701
RECORDER
Fan
READY/BUSY OUT
ERROR OUT
ProStar 410
AutoSampler
ProStar 363
Fluorescence Detector
PEAK
+13VDC
4
5
ANALOG
ADVANCE
Can send data to
800 MIB using the
cable PN 390793806
EVT MARK
Serial out
INJECT
Power
INPUTS
P2 cable
RACK
P1 cable
3
OUTPUTS
MARKER IN
2
CHASSIS
1
A-GND
R007200141
LAMP OFF
GND
START IN
AUTO ZERO OUT
10
Star WS Control of
ProStar 210/218 Pumps, with 500 CVM,
320 UV Detector, and 410 AutoSampler
Back connectors for 210/218
(internal CIM)
11
INTGR 1
500 CVM
HI
INTGR 1
LOW
INTGR 1
GRD
CHASSIS
GRD
ANALOG
OUT
ANALOG
OUT GRD
ProStar 210/218 Pumps
1
2
9 - Pin connectors
comm1
3
comm2
serial communication ribbon
AUX
+5V
AUX
GND
03-935462-91
connect to comm1
or comm2
STOP
R
S
4
2
2
D GRD
HOLD
D GRD
ProStar 320 UV Detector
Back Plate
TRANSFER
D GRD
REC HI
INJECT
REC
LOW
CPU
D GRD
MARK
REC
GRD
D GRD
ProStar 701
INT HI
INIT
LOW
11
5
ANALOG
CHASSIS
PEAK
+13VDC
ProStar 410
AutoSampler
4
A-GND
ADVANCE
To Contact 2 of 210/
218 back connector
EVT MARK
EVENT
MARK
D GRD
INJECT
AUTO
ZERO
3
RACK
P2 cable
2
INPUTS
LAMP
ON/OFF
P1 cable
1
PN R007200141
OUTPUTS
EXT
WAVE HI
EXT WAVE
LOW
GND
INIT
GRD
Star WS Control of
ProStar 230 Pump, 310 UV Detector,
and 410 AutoSampler
ProStar 230 Pump
Position sensing
switch of Rheodyne
manual injector is
connected to Start In
comm1
1v
Data system
output 2AUFS
1mV
Chart recorder
Output
Start In Start In +
Ready In Ready In +
J9
Fault In Fault In +
Gnd
Gnd
Start Out Start Out +
Ready Out Ready Out + J10
Fault Out Fault Out +
Ready In enable
+5V
comm2
10V (switch)
10mV (switch)
Peak sensing relay
Relay 1
Device Address
Relay 2
Relay 3
Relay 4
J9
Syn Signal
J10
GPIB cable
PN 81-839700-00
-
connect to comm1
or comm2
serial communication ribbon
03-935462-91
GPIB Interface
CPU
1v
Data system
output 2AUFS
1mV
Chart recorder
Output
10V
ProStar 701
10mV
Peak sensing relay
Relay 1
4
5
ANALOG
CHASSIS
2
A-GND
1
GND
Device Address
Relay 2
3
ADVANCE
PEAK
EVT MARK
+13VDC
Syn Signal
J10
ProStar 410
AutoSampler
INJECT
P2 cable
INPUTS
J9
P1 cable
RACK
Relay 4
OUTPUTS
Relay 3
ProStar 310 UV Detector
Connected to GPIB
slot in the CPU using
cable PN 81-839700-00
12
Star WS Control of
ProStar 230 Pump,
320 UV Detector, 800 MIB,
and 410 AutoSampler
comm1
ProStar 230 Pump
Position sensing
switch of Rheodyne
manual injector is
connected to Start In
1v
Data system
output 2AUFS
1mV
Chart recorder
Output
Start In Start In +
Ready In Ready In +
J9
Fault In Fault In +
Gnd
Gnd
Start Out Start Out +
Ready Out Ready Out + J10
Fault Out Fault Out +
Ready In enable
+5V
comm2
10V (switch)
10mV (switch)
Peak sensing relay
Relay 1
Device Address
Relay 2
Relay 3
Relay 4
J9
Syn Signal
J10
GPIB cable
P/N 81-839700-00
Ethernet Communication
Crossover Cable
connect to comm1
or comm2
p /n 393320601
800 MIB
Analog Cable
390793802
REC HI
GPIB Interface
REC
LOW
CPU
serial communication ribbon
03-935462-91
REC
GRD
INT HI
ProStar 701
INIT
LOW
INIT
GRD
EXT
WAVE HI
ProStar 410
AutoSampler
PEAK
A-GND
+13VDC
GND
5
ANALOG
ADVANCE
D GRD
EVT MARK
EVENT
MARK
INJECT
P2 cable
4
INPUTS
P1 cable
NOTE: Lamp ON/OFF,
autozero can be connected
to Relay 2 & 3 respectively
of the 230 pump using the
cable P/N 02-001594-00.
3
RACK
AUTO
ZERO
2
OUTPUTS
1
LAMP
ON/OFF
CHASSIS
EXT WAVE
LOW
ProStar 320 UV Detector
back plate
13
Star WS Control of ProStar 230 Pump,
330 PDA Detector, 410 AutoSampler
and 701 Fraction Collector
ProStar 230 Pump
Position sensing
switch of Rheodyne
manual injector is
connected to Start In
Start In Start In +
Ready In Ready In +
J9
Fault In Fault In +
Gnd
Gnd
Start Out Start Out +
Ready Out Ready Out + J10
Fault Out Fault Out +
Ready In enable
+5V
comm2
10V (switch)
10mV (switch)
Peak sensing relay
Relay 1
Device Address
Relay 2
Relay 3
Relay 4
J9
Syn Signal
J10
GPIB cable
P/N 81-839700-00
connect to comm1
or comm2
D-line
Connectors use
cable p/n
0393571701
serial communication ribbon
GPIB Interface 2 at
address 1
03-935462-91
GPIB Interface 1 at
address 0
CPU
ProStar 330
ProStar 410
AutoSampler
ANALOG
PEAK
+13VDC
5
CHASSIS
ADVANCE
EVT MARK
4
A-GND
INJECT
P2 cable
Connected to GPIB
slot in the CPU using
cable P/N 81839700-00
3
RACK
P1 cable
2
INPUTS
1
Analog I/O board
p/n 0393592191
GND
ProStar 701
OUTPUTS
comm1
1v
Data system
output 2AUFS
1mV
Chart recorder
Output
14
Star WS Control of
ProStar 230 Pump,
363 Fluorescence Detector,
800 MIB, and 410 AutoSampler
comm1
ProStar 230 Pump
Position sensing
switch of Rheodyne
manual injector is
connected to Start In
1v
Data system
output 2AUFS
1mV
Chart recorder
Output
Start In Start In +
Ready In Ready In +
J9
Fault In Fault In +
Gnd
Gnd
Start Out Start Out +
Ready Out Ready Out + J10
Fault Out Fault Out +
Ready In enable
+5V
comm2
10V (switch)
10mV (switch)
Peak sensing relay
Relay 1
Device Address
Relay 2
Relay 3
Relay 4
J9
Syn Signal
J10
PN 81-839700-00
GPIB cable
Ethernet Communication
Crossover Cable
393320601
connect to comm1
or comm2
800 MIB
serial communication ribbon
03-935462-91
Analog Cable for 363 only
390793806
GPIB Interface
CPU
PROCESSOR
RECORDER
ProStar 701
READY/BUSY OUT
Fan
ERROR OUT
ADVANCE
PEAK
EVT MARK
+13VDC
Power
ProStar 410
AutoSampler
Serial out
5
ANALOG
INJECT
P2 cable
4
CHASSIS
INPUTS
RACK
P1 cable
3
OUTPUTS
MARKER IN
2
A-GND
1
LAMP OFF
GND
START IN
AUTO ZERO OUT
ProStar 363
Fluorescence Detector
15
Back connectors for SD-1
(To internal CIM)
Back Connector
7725i
ProStar SD-1
Star WS Control of
Pumps
PrepStar SD-1 Pumps,
320 UV Detector, and 410 AutoSampler
TB 3
RELAY PUTPUT
TB 2
DIGITAL INPUT
TB1
ANALOG
INTGR 1
HI
STOP
D GRD
INTGR 1
LOW
INTGR 1
GRD
CHASSIS
GRD
TRANSFER
INTGR 2
HI
D GRD
HOLD
9-Pin connectors
comm2
INTGR 2
LOW
INTGR 2
GRD
CHASSIS
GRD
CHASSIS
GRD
ANALOG
OUT
D GRD
serial communication
ribbon
INJECT
D GRD
03-935462-91
connected to
comm1 or
comm2
MARK
D GRD
ANALOG
OUT GRD
CHASSIS
GRD
AUX
+5V
CHASSIS
GRD
ProStar 320 UV
Detector Back Plate
REC HI
CPU
REC
LOW
REC
GRD
ProStar 701
INT HI
INIT
LOW
INIT
GRD
PEAK
A-GND
+13VDC
GND
To Contact 1 of SD-1
back connector
ADVANCE
EVENT
MARK
To Contact 2 of SD-1
back connector
EVT MARK
AUTO
ZERO
4
INJECT
P2 cable
3
RACK
P1 cable
2
INPUTS
LAMP
ON/OFF
1
5
ANALOG
PN R007200141
EXT WAVE
LOW
OUTPUTS
EXT
WAVE HI
CHASSIS
comm1
D GRD
ProStar 410 AutoSampler
16
Star WS Control of
PrepStar SD-1 Pumps,
500 CMV, 320 UV Detector,
and 410 AutoSampler
Back connectors for SD-1
(To internal CIM)
500 CVM
Back Connector
ProStar SD-1
Pumps
TB 3
RELAY PUTPUT
TB 2
DIGITAL INPUT
TB1
ANALOG
INTGR 1
HI
STOP
D GRD
INTGR 1
LOW
INTGR 1
GRD
CHASSIS
GRD
TRANSFER
INTGR 2
HI
D GRD
HOLD
9-Pin connectors
comm1
comm2
serial communication
ribbon
connected to
comm1 or
comm2
D GRD
INTGR 2
LOW
INJECT
INTGR 2
GRD
MARK
CHASSIS
S GRD
CHASSIS
GRD
D GRD
ANALOG
OUT
AUX
+5V
CHASSIS
GRD
ANALOG
OUT GRD
CHASSIS
GRD
D GRD
03-935462-91
Pro Star 320 UV
Detector Back Plate
REC HI
REC
LOW
CPU
REC
GRD
ProStar 701
INT HI
INIT
LOW
INIT
GRD
ProStar 410
AutoSampler
ADVANCE
PEAK
A-GND
ANALOG
+13VDC
GND
CHASSIS
To Contact 2 of SD-1
back connector
5
EVT MARK
EVENT
MARK
4
INJECT
AUTO
ZERO
3
RACK
P2 cable
2
INPUTS
LAMP
ON/OFF
P1 cable
1
PN R007200141
OUTPUTS
EXT
WAVE HI
EXT WAVE
LOW
D GRD
17
Star WS Control of
PrepStar SD-1 Pumps,
320 UV Detector, 430 AutoSampler
and 510 Mistral Oven
Back connectors for SD-1
(To internal CIM)
Back Connector
7725i
Model SD-1
Pumps
TB 3
RELAY PUTPUT
TB 2
DIGITAL INPUT
TB1
ANALOG
D GRD
INTGR 1
HI
INTGR 1
LOW
INTGR 1
GRD
CHASSIS
GRD
TRANSFER
INTGR 2
HI
STOP
D GRD
HOLD
serial communication
ribbon
comm1
9-Pin connectors
comm2
INTGR 2
LOW
INTGR 2
GRD
D GRD
serial communication
ribbon
INJECT
CHASSIS
GRD
CHASSIS
GRD
ANALOG
OUT
ANALOG
OUT GRD
CHASSIS
GRD
D
GRD
03-935462-91
MARK
connected to
COMM1
D GRD
AUX
+5V
CHASSIS
GRD
ProStar 320 UV
Detector Back Plate
REC HI
ProStar 430
AutoSampler
REC
LOW
CPU
REC
GRD
INT HI
ProStar 701
INIT
LOW
INIT
GRD
A-GND
GND
5
ANALOG
PEAK
+13VDC
To Contact 1 of SD
- 1
back connector
ADVANCE
EVENT
MARK
- 1
To Contact 2 of SD
back connector
4
EVT MARK
AUTO
ZERO
3
INJECT
P6
INPUTS
LAMP
ON/OFF
2
RACK
P4
MARKER
RELAY
Mistral
ProStar
510 Oven
1
CHASSIS
PN R007200141
EXT WAVE
LOW
INPUTS
EXT
WAVE HI
OUTPUTS
COM
PORT
D GRD
18
Galaxie Control Contents
Pumps
20
210/215/218
220/230/240
SD-1
X
Detectors
20
310
320
325/335
330
340
345
350/352
363
X
21
X
X
21
22
X
X
23
X
23
24
X
24
25
26
27
28
X
X
X
X
25
26
27
28
X
X
X
X
See Operation Manual
AutoSampler
20
21
400
410
420/430
X
X
X
24
25
26
27
28
X
X
X
X
X
X
4
5
6
7
8
9
X
X
X
X
See Operation Manual
X
X
X
X
X
X
X
X
X
X
X
2
X
22
X
23
1
500
510
701
704
WS
800 MIB
22
X
3
X
X
19
Galaxie CDS Control through 800 MIB of
ProStar 210/218 Pumps, 310 UV Detector,
and 410 AutoSampler
Back connectors for ProStar 210/218
(to internal CIM)
INTGR 1
HI
INTGR 1
LOW
INTGR 1
GRD
CHASSI
S GRD
ANALOG
OUT
ANALOG
OUT GRD
7725i
ProStar 210/218
Pumps
1
2
9-Pin connectors
3
AUX
+5V
AUX
GND
serial communication ribbon
03-935462-91
800 MIB
STOP
D GRD
Network
HOLD
D GRD
TRANSFER
03-907938-14
Serial Cable RJ45 to 9 Pin
D GRD
INJECT
D GRD
MARK
1v
Data system
output 2AUFS
1mV
Chart recorder
Output
D GRD
10V
ProStar 701
10mV
Peak sensing relay
Relay 1
Device Address
Relay 2
1
2
3
4
5
PEAK
A-GND
+13VDC
GND
P2 cable
ProStar 410 AutoSampler
J10
ProStar 310 UV Detector
Connected to GPIB
slot in the CPU using
cable P/N 81839700-00
ANALOG
ADVANCE
EVT MARK
Syn Signal
P1 cable
CHASSIS
INJECT
RACK
J9
INPUTS
Relay 4
OUTPUTS
Relay 3
20
Galaxie CDS Control through 800 MIB
of ProStar 210/218 Pumps, 320 UV Detector,
410 AutoSampler, and 701 FC
Back connectors for 210/218
for 210/218
(To internal CIM)
7725i
INTGR 1
HI
INTGR 1
LOW
INTGR 1
GRD
CHASSIS
GRD
ANALOG
OUT
ANALOG
OUT GRD
ProStar 210/218
Pumps
1
2
9-Pin connectors
3
serial communication ribbon
AUX
+5V
03-935462-91
AUX
GND
800 MIB
Network
STOP
D GRD
Connect to
comm 1, 2, 3 or 4
HOLD
D GRD
03-907938-14
ProStar 320 UV
Detector Back Plate
TRANSFER
D GRD
REC HI
INJECT
REC
LOW
D GRD
MARK
REC
GRD
D GRD
ProStar 701
INT HI
INIT
LOW
ProStar 410 AutoSampler
21
PEAK
+13VDC
4
5
ANALOG
ADVANCE
To Contact 1 of 210 /
218 back connector
EVT MARK
EVENT
MARK
D GRD
To Contact 2 of 210/218
back connector
INJECT
AUTO
ZERO
INPUTS
P2 cable
RACK
P1 cable
3
OUTPUTS
LOW
LAMP
ON/OFF
2
CHASSIS
1
PN R007200141
A-GND
EXT
WAVE HI
EXT WAVE
GND
INIT
GRD
Galaxie CDS Control through 800 MIB
of ProStar 210/218 Pumps,
320 UV Detector, and 430 AutoSampler
with a 510 Mistral Oven
Back connectors for 210/218
(To internal CIM)
INTGR 1
HI
INTGR 1
LOW
INTGR 1
GRD
CHASSIS
GRD
ANALOG
OUT
ANALOG
OUT GRD
7725i
ProStar 210/218
Pumps
1
2
800 MIB
serial communication
ribbon
9-Pin connectors
3
Network
Connect to
comm 1, 2, 3 or 4
connected to
comm1 or
comm2
AUX
+5V
serial communication ribbon
03 935462 91
-
AUX
GND
STOP
03-907938-14
D GRD
HOLD
D GRD
ProStar 320 UV
Detector Back Plate
TRANSFER
D GRD
REC HI
INJECT
REC
LOW
D GRD
MARK
REC
GRD
D GRD
INT HI
ProStar 701
INIT
LOW
COM
PORT
ProStar 430 AutoSampler
22
4
5
A-GND
ANALOG
CHASSIS
PEAK
To Contact 1 of 210/218
back connector
+13VDC
EVENT
MARK
D GRD
To Contact 2 of 210/218
back connector
ADVANCE
AUTO
ZERO
3
EVT MARK
LAMP
ON/OFF
2
INJECT
510 Mistral
Oven
1
INPUTS
P6
INPUTS
EXT WAVE
LOW
RACK
P4
MARKER
RELAY
PN R007200141
OUTPUTS
EXT
WAVE HI
GND
INIT
GRD
Galaxie CDS Control through 800 MIB of
ProStar 210/218 Pumps, 345 UV Detector,
and 410 AutoSampler
INTGR 1
HI
INTGR 1
LOW
INTGR 1
GRD
CHASSIS
GRD
ANALOG
OUT
ANALOG
OUT GRD
7725i
ProStar 210/215 Pumps
1
2
serial communication ribbon
9 -Pin connectors
3
03-935462-91
AUX
+5V
AUX
GND
03-907938-14
STOP
D GRD
HOLD
D GRD
800 MIB
TRANSFER
STOP
Analog cable to 800MIB
0390793802
.01 V F /S
GND
RUN /
START
GND
.10 V F /S
CH .1
.01 V F /S
P2 cable
ProStar 410 AutoSampler
CH .2
D GRD
MARK
D GRD
ZERO
1 .0 V F / S
ANALOG
GND
P1 cable
D GRD
INJECT
.10 V F /S
GND
GND
GND
NOT
READY
N.O.
1 .0 V F / S
COMM
ANALOG
GND
N.C.
23
ProStar 345 Back Plate
Galaxie CDS Control through 800 MIB
of ProStar 210/218 Pumps,
363 Fluorescence Detector, and
410 AutoSampler
7725i
ProStar 210/218
Pumps
9 - Pin connectors
serial communication ribbon
03-935462-91
800 MIB
STOP
Connect to
comm 1, 2, 3 or 4
D GRD
HOLD
D GRD
TRANSFER
03-907938-14
D GRD
INJECT
03-907938-06
D GRD
MARK
PROCESSOR
D GRD
ProStar 701
RECORDER
Fan
READY/BUSY OUT
ERROR OUT
ProStar 410
AutoSampler
Serial out
ProStar 363
Fluorescence Detector
ANALOG
ADVANCE
EVT MARK
Power
5
CHASSIS
INJECT
P2 cable
4
A-GND
INPUTS
P1 cable
RACK
MARKER IN
2
GND
1
PEAK
R007200141
LAMP OFF
+13VDC
START IN
AUTO ZERO OUT
OUTPUTS
Network
AUX
+5V
AUX
GND
3
24
Galaxie CDS Control through 800 MIB
of ProStar 230 Pump, 310 UV Detector
and 410 AutoSampler
ProStar 230 Pump
Position sensing
switch of Rheodyne
manual injector is
connected to Start In
1v
Data system
output 2AUFS
1mV
Chart recorder
Output
Start In Start In +
Ready In Ready In +
J9
Fault In Fault In +
Gnd
Gnd
Start Out Start Out +
Ready Out Ready Out + J10
Fault Out Fault Out +
Ready In enable
+5V
10mV (switch)
Peak sensing relay
Relay 1
Device Address
Relay 2
Relay 3
Relay 4
J9
Syn Signal
J10
GPIB Cable Extender
81-839794-00
GPIB cable
PN 81-839700-00
-
800 MIB
Connect to
comm 1, 2, 3 or 4
serial communication ribbon
03-935462-91
03-907938-14
1v
Data system
output 2AUFS
1mV
Chart recorder
Output
10V
ProStar 701
10mV
Peak sensing relay
Relay 1
4
5
A-GND
ANALOG
GND
CHASSIS
2
PEAK
1
+13VDC
Device Address
Relay 2
3
ADVANCE
Syn Signal
J10
ProStar 410
AutoSampler
EVT MARK
P2 cable
INJECT
J9
P1 cable
INPUTS
Relay 4
RACK
Relay 3
OUTPUTS
Network
10V (switch)
ProStar 310 UV Detector
Connected to GPIB
slot in the CPU using
cable PN 81-839700-00
25
Galaxie CDS Control through 800 MIB
of ProStar 230 Pump, 320 UV Detector, and
410 AutoSampler
Position sensing
ProStar 230 Pump
switch of Rheodyne
manual injector is
connected to Start In
1v
Data system
output 2AUFS
1mV
Chart recorder
Output
Start In Start In +
Ready In Ready In +
J9
Fault In Fault In +
Gnd
Gnd
Start Out Start Out +
Ready Out Ready Out + J10
Fault Out Fault Out +
Ready In enable
+5V
10V (switch)
10mV (switch)
Peak sensing relay
Relay 1
Device Address
Relay 2
Relay 3
Relay 4
J9
Syn Signal
J10
GPIB Cable Extender
81-839704-00
800 MIB
Network
03-907938-14
03-907938-14
serial communication ribbon
03-935462-91
Analog Cable 390793802
REC HI
ProStar 701
REC
LOW
REC
GRD
INT HI
INIT
LOW
P1 cable
P2 cable
INIT
GRD
EXT
WAVE HI
ADVANCE
PEAK
A-GND
ANALOG
EVT MARK
+13VDC
GND
CHASSIS
5
INJECT
EVENT
MARK
NOTE: Lamp ON /OFF,
autozero can be connected
to Relay 2 & 3 respectively
of the 230 pump using the
cable P/N 02-001594-00.
4
INPUTS
AUTO
ZERO
3
RACK
LAMP
ON/OFF
2
OUTPUTS
ProStar 410
AutoSampler
1
EXT WAVE
LOW
D GRD
ProStar 320 UV Detector
back plate
26
Galaxie CDS Control through 800 MIB
of ProStar 230 Pump, 325/335 PDA Detector,
410 AutoSampler and Fraction Collector
ProStar 230 Pump
Position sensing
switch of Rheodyne
manual injector is
connected to Start In
1v
Data system
output 2AUFS
1mV
Chart recorder
Output
Start In Start In +
Ready In Ready In +
J9
Fault In Fault In +
Gnd
Gnd
Start Out Start Out +
Ready Out Ready Out + J10
Fault Out Fault Out +
Ready In enable
+5V
10V (switch)
10mV (switch)
Peak sensing relay
Relay 1
Device Address
Relay 2
Relay 3
Relay 4
J9
Syn Signal
J10
(required for 335)
Ethernet
Acquistion Server
GPIB Cable Extender
81-839704-00
GPIB cable
P/N 81-839700-00
800 MIB
Connect to
comm 1, 2, 3 or 4
serial communication ribbon
D-line
Connectors use
cable p/n
0393571701
03-935462-91
03-907938-14
Ethernet Switch
Network
ProStar 701
ADVANCE
PEAK
A-GND
ANALOG
EVT MARK
+13VDC
GND
CHASSIS
5
INJECT
ProStar 325/335
4
RACK
P2 cable
ProStar 410
AutoSampler
3
INPUTS
P1 cable
2
OUTPUTS
1
27
Galaxie CDS Control of ProStar 230 Pump,
363 Fluorescence Detector, 800 MIB,
and 410 AutoSampler
ProStar 230 Pump
Position sensing
switch of Rheodyne
manual injector is
connected to Start In
1v
Data system
output 2AUFS
1mV
Chart recorder
Output
Start In Start In +
Ready In Ready In +
J9
Fault In Fault In +
Gnd
Gnd
Start Out Start Out +
Ready Out Ready Out + J10
Fault Out Fault Out +
Ready In enable
+5V
10V (switch)
10mV (switch)
Peak sensing relay
Relay 1
Device Address
Relay 2
Relay 3
Relay 4
J9
Syn Signal
J10
PN 81-839700-00
GPIB cable
800 MIB
Network
serial communication ribbon
03-935462-91
Analog Cable for 363 only
390793806
PROCESSOR
RECORDER
ProStar 701
READY/BUSY OUT
Fan
ERROR OUT
START IN
1
AUTO ZERO OUT
ProStar 410
AutoSampler
ADVANCE
PEAK
A-GND
ANALOG
EVT MARK
+13VDC
GND
CHASSIS
Serial out
ProStar 363
Fluorescence Detector
5
INJECT
P2 cable
Power
4
RACK
P1 cable
3
INPUTS
MARKER IN
2
OUTPUTS
LAMP OFF
28
Stand-alone Control Contents
Pumps
30
210/215/218
220/230/240
31
32
33
34
X
X
X
X
X
35
36
37
38
39
40
41
X
X
X
35
36
42
43
44
45
X
X
X
X
X
X
X
X
38
39
41
41
42
43
44
X
X
X
X
46
X
SD-1
Detectors
30
310
X
31
33
34
37
X
X
320
32
X
X
X
45
46
X
X
325/335
330
X
340
X
345
350/353
X
X
X
36
37
See Operation Manual
363
AutoSampler
30
31
33
34
35
X
400
410
32
X
X
X
420/430
X
X
38
39
X
X
41
41
42
43
44
45
46
X
X
X
X
X
X
X
X
X
30
31
32
33
34
35
36
37
38
39
41
41
42
43
44
45
46
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
500
510
701
704
See Operation Manual
WS
800 MIB
29
ProStar 220/230/240 Pump (Master),
310 UV Detector, and 410 AutoSampler
ProStar 220/230/240 Pump
1v
10V (switch)
1mV
10mV (switch)
Data system
output 2AUFS
Start In Start In +
Ready In Ready In +
Fault In Fault In +
Gnd
Gnd
Start Out Start Out +
Ready Out Ready Out +
Fault Out Fault Out +
Ready In enable
+5V
Sync Cable Kit
03-91994890
Chart recorder
Output
J9
Peak sensing relay
Relay 1
Device Address
Relay 2
Relay 3
Relay 4
J10
J9
Syn Signal
J10
Signal Cable
02-001954-00
Position sensing
switch of
Rheodyne
manual injector
is connected to
Start In
Start In Start In +
Ready In Ready In +
Fault In Fault In +
Gnd
Gnd
Start Out Start Out +
Ready Out Ready Out +
Fault Out Fault Out +
Ready In enable
+5V
Sync cable for
ProStar 410
AutoSampler
0393516301
J9
1v
Data system
output 2AUFS
J10
1mV
Chart recorder
Output
10V (switch)
10mV (switch)
Peak sensing relay
Relay 1
Relay 2
Device Address
Relay 3
ProStar 701
Relay 4
J9
Clear +ve
Syn Signal
ADVANCE
PEAK
A-GND
+13VDC
GND
5
ANALOG
4
EVT MARK
Detail
CHASSIS
ProStar 410 AutoSampler
3
INJECT
P2 cable
2
RACK
P1 cable
1
INPUTS
ProStar 310 UV-Detector
OUTPUTS
J10
Black -ve
30
210/215/218 Pump (Master),
320 UV Detector, and 410 AutoSampler
Extension cable
R000815107
INTGR 1
HI
INTGR 1
LOW
INTGR 1
GRD
CHASSIS
GRD
ANALOG
OUT
ANALOG
OUT GRD
AUX
+5V
210/215/218 Pump
Position sensing
switch of Rheodyne
manual injector is
connected to Start In
AUX
GND
STOP
D GRD
HOLD
D GRD
TRANSFER
1
D GRD
INJECT
2
D GRD
3
MARK
D GRD
Shielded cable
R007200141
REC HI
REC
LOW
REC
GRD
INT HI
INIT
LOW
ProStar 701
Shielded cable
R007200141
INIT
GRD
EXT
WAVE HI
Shielded cable
R007200141
ADVANCE
PEAK
A-GND
+13VDC
GND
ProStar 320 UV-Detector
EVT MARK
D GRD
INJECT
P2 cable
4
INPUTS
P1 cable
NOTE: Lamp ON/OFF,
autozero can be connected to
Relay 2 & 3 respectively of the
ProStar 220/230/240 pump
using the cable 02-001594-00.
3
RACK
AUTO
ZERO
EVENT
MARK
2
OUTPUTS
1
LAMP
ON/OFF
5
ANALOG
EXT WAVE
LOW
Detail
CHASSIS
Sync cable for
ProStar 410
AutoSamplers
0393516301
ProStar 410 AutoSampler
31
210/215/218 Pump (Master), 320 UV
Detector, and 400 AutoSampler
Extension cable
R000815107
INTGR 1
HI
INTGR 1
LOW
INTGR 1
GRD
CHASSIS
GRD
ANALOG
OUT
ANALOG
OUT GRD
AUX
+5V
210/215/218 Pump
Position sensing
switch of Rheodyne
manual injector is
connected to Start In
AUX
GND
STOP
D GRD
HOLD
D GRD
TRANSFER
1
D GRD
INJECT
2
D
GRD
3
MARK
D GRD
Shielded cable
R007200141
REC HI
REC
LOW
REC
GRD
INT HI
INIT
LOW
ProStar 701
Shielded cable
R007200141
INIT
GRD
EXT
WAVE HI
A-GND
GND
5
ANALOG
PEAK
+13VDC
ProStar 320 UV-Detector
ADVANCE
D GRD
NOTE: Lamp ON/OFF,
autozero can be connected to
Relay 2 & 3 respectively of the
ProStar 220/230/240 pump
using the cable 02-001594-00.
4
EVT MARK
EVENT
MARK
3
INJECT
AUTO
ZERO
2
RACK
1
LAMP
ON/OFF
INPUTS
CONTROL I/O
OUTPUTS
COMM
PORT
Shielded cable
R007200141
EXT WAVE
LOW
Detail
CHASSIS
Sync cable for
ProStar 400
AutoSamplers
0393516201
ProStar 400 AutoSampler
32
210/215/218 Pump (Master), 320 UV
Detector, and 420/430 AutoSampler
Extension cable
R000815107
INTGR 1
HI
INTGR 1
LOW
INTGR 1
GRD
CHASSIS
GRD
ANALOG
OUT
ANALOG
OUT GRD
AUX
+5V
210/215/218 Pump
Position sensing
switch of Rheodyne
manual injector is
connected to Start In
AUX
GND
STOP
D GRD
HOLD
D GRD
TRANSFER
1
D GRD
INJECT
2
D GRD
3
MARK
D GRD
Shielded cable
R007200141
Sync cable for
ProStar 420/430
AutoSamplers
0393516101
REC HI
REC
LOW
REC
GRD
INT HI
INIT
LOW
ProStar 701
INIT
GRD
Shielded cable R007200141
EXT
WAVE HI
2
3
4
INPUTS
INJECT
ADVANCE
PEAK
A-GND
EVT MARK
+13VDC
GND
LAMP
ON/OFF
P6
INPUTS
AUTO
ZERO
EVENT
MARK
D GRD
ProStar 420/430 AutoSampler
NOTE: Lamp ON/OFF, autozero can be
connected to Relay 2 & 3 respectively of
the ProStar 220/230/240 pump using the
cable 02-001594-00.
ProStar 320 UV-Detector
5
Detail
CHASSIS
P4
MARKER
RELAY
ANALOG
1
RACK
Shielded cable
R007200141
EXT WAVE
LOW
OUTPUTS
COM
PORT
33
210/215/218 Pump (Master), 340 UV
Detector, and 420/430 AutoSampler
Extension cable
R000815107
INTGR 1
HI
INTGR 1
LOW
INTGR 1
GRD
CHASSIS
GRD
ANALOG
OUT
ANALOG
OUT GRD
210/215/218 Pump
Position sensing
switch of Rheodyne
manual injector is
connected to Start In
STOP
D GRD
HOLD
D GRD
TRANSFER
1
D GRD
INJECT
2
NOTE:
AUX
+5V
AUX
GND
D GRD
Please refer to the
other detector
diagrams for
connection with
the other
AutoSamplers
3
MARK
D GRD
Shielded cable
R007200141
Shielded cable
R007200141
+
1
-
2
+
-
3
+
4
-
EVENT
+
-
5
+
-
ProStar 701
Shielded cable
R007200141
6
INPUTS
INJECT
ADVANCE
PEAK
EVT MARK
+13VDC
ProStar 340 UV-Detector
3
RACK
P6
INPUTS
2
OUTPUTS
1
P4
MARKER
RELAY
4
5
ANALOG
COM
PORT
INT
1AU/V
CHASSIS
RECORDER
REMOTE
AUTO
ZERO
A-GND
OUTPUT
GND
Sync cable for
ProStar 420/430
AutoSampler
0393516101
Detail
ProStar 420/430 AutoSampler
34
ProStar 220/230/240 Pump (Master),
340 UV Detector, and 410
AutoSampler
ProStar 220/230/240 Pump
Position sensing switch of
Rheodyne manual injector
is connected to Start In
Start In Start In +
Ready In Ready In +
Fault In Fault In +
Gnd
Gnd
Start Out Start Out +
Ready Out Ready Out +
Fault Out Fault Out +
Ready In enable
+5V
1v
Data system
output 2AUFS
1mV
Chart recorder
Output
J9
10V
(switch)
10mV (switch)
Peak sensing relay
Relay 1
Device Address
Relay 2
Relay 3
Relay 4
J10
J9
Syn Signal
J10
Shielded cable,
R007200141
OUTPUT
Sync cable for
ProStar 410
AutoSampler
0393516301
RECORDER
+
1
NOTE:
-
2
Signal Cable
02-001954-00
REMOTE
INT
1AU/V
+
-
3
AUTO
ZERO
+
4
-
EVENT
+
-
5
+
-
6
Please refer the
appropriate diagram for
connections to the other
AutoSamplers
Clear +ve
INPUTS
INJECT
ADVANCE
PEAK
A-GND
EVT MARK
+13VDC
GND
To the appropriate
Integrator
5
ANALOG
4
CHASSIS
3
Detail
P2 cable
ProStar 410 AutoSampler
2
RACK
P1 cable
1
OUTPUTS
ProStar 340 UV-Detector
back plate
Black +ve
ProStar 701
35
ProStar 220/230/240 Pump (Master), 345 UV and
360 Fluorescence Detectors, and 410 AutoSampler
ProStar 220/230/240 Pump
Position sensing switch of
Rheodyne manual injector
is connected to Start In
J9
10V (switch)
10mV (switch)
Peak sensing relay
Relay 1
Device Address
Relay 2
Relay 3
Signal Cable
02-001954-00
Relay 4
J10
J9
Syn Signal
J10
To the appropriate
integrator
Shielded cable
R007200141
STOP
.01 V F/S
GND
RUN/START
.10 V F/S
CH.1
GND
Shielded cable
R007200141
ANALOG
GND
ZERO
NOTE:
Please refer the
appropriate diagram for
connections to the other
AutoSamplers
1.0 V F/S
GND
.01 V F/S
GND
CH.2
GND
NOT READY
N.O.
.10 V F/S
1.0 V F/S
ANALOG
GND
Clear +ve
1
INJECT
ADVANCE
PEAK
A-GND
EVT MARK
+13VDC
GND
P2 cable
4
INPUTS
P1 cable
3
RACK
N.C.
2
OUTPUTS
COMM
5
ANALOG
Sync cable for
ProStar 410
AutoSampler
0393516301
Signal Cable
02-001954-00
Detail
ProStar 345/360 Detector
ProStar 410 Autosampler
CHASSIS
Start In Start In +
Ready In Ready In +
Fault In Fault In +
Gnd
Gnd
Start Out Start Out +
Ready Out Ready Out +
Fault Out Fault Out +
Ready In enable
+5V
1v
Data system
output 2AUFS
1mV
Chart recorder
Output
Black +ve
ProStar 701
36
210/215/218 Pump (Master), 345 UV & 360
Fluorescence Detectors, and 420/430 AutoSampler
INTGR 1
HI
INTGR 1
LOW
INTGR 1
GRD
CHASSIS
GRD
ANALOG
OUT
ANALOG
OUT GRD
Extension cable
R000815107
210/215/218 Pump
Position sensing
switch of
Rheodyne
manual injector
is connected to
Start In
HOLD
TRANSFER
D GRD
INJECT
2
D GRD
3
MARK
D GRD
Shielded cable
R007200141
.01 V F/S
STOP
GND
.10 V F/S
CH.1
ANALOG
GND
.01 V F/S
3
4
5
ANALOG
Detail
2
CHASSIS
N.O.
1
A-GND
P6
INPUTS
ANALOG
GND
GND
NOT READY
1.0 V F/S
PEAK
GND
.10 V F/S
+13VDC
CH.2
Shielded cable
R007200141
ADVANCE
GND
ProStar 701
EVT MARK
GND
INJECT
ZERO
RACK
GND
COM
PORT
1.0 V F/S
INPUTS
RUN/START
Shielded cable
R007200141
OUTPUTS
Sync cable for
ProStar 420/430
AutoSamplers
0393516101
P4
MARKER
RELAY
STOP
D GRD
D GRD
1
NOTE:
Please refer to the
other detector
diagrams for
connection with the
other AutoSamplers
AUX
+5V
AUX
GND
COMM
N.C.
ProStar 420/430 AutoSampler
ProStar 345/360 Detector
37
ProStar 220/230/240 Pump
(Master), 310 UV Detector, and 400
ProStar 220/230/240 Pump
AutoSampler
1v
10V (switch)
Data system
output 2AUFS
Start In Start In +
Ready In Ready In +
Fault In Fault In +
Gnd
Gnd
Start Out Start Out +
Ready Out Ready Out +
Fault Out Fault Out +
Ready In enable
+5V
Sync Cable Kit
03-91994890
1mV
10mV (switch)
Chart recorder
Output
J9
Peak sensing relay
Relay 1
Device Address
Relay 2
Relay 3
Relay 4
J10
J9
Syn Signal
J10
Signal Cable
02-001954-00
Position sensing
switch of Rheodyne
manual injector is
connected to Start In
Sync cable for
ProStar 400
AutoSampler
0393516201
Start In Start In +
Ready In Ready In +
Fault In Fault In +
Gnd
Gnd
Start Out Start Out +
Ready Out Ready Out +
Fault Out Fault Out +
Ready In enable
+5V
J9
1v
Data system
output 2AUFS
J10
1mV
Chart recorder
Output
10V (switch)
10mV (switch)
Peak sensing relay
Relay 1
Device Address
Relay 2
Relay 3
ProStar 701
Relay 4
J9
Clear +ve
Syn Signal
2
3
4
INPUTS
INJECT
ADVANCE
PEAK
A-GND
RACK
EVT MARK
+13VDC
GND
CONTROL I/O
ProStar 310 UV-Detector
5
ANALOG
1
OUTPUTS
J10
COMM
PORT
CHASSIS
Detail
ProStar 400 AutoSampler
Black -ve
38
ProStar 220/230/240 Pump (Master), 320
UV Detector, and 400 AutoSampler
ProStar 220/230/240 Pump
Position sensing
switch of Rheodyne
manual injector is
connected to Start In
1v
10V (switch)
1mV
10mV (switch)
Data system
output 2AUFS
Start In Start In +
Ready In Ready In +
Fault In Fault In +
Gnd
Gnd
Start Out Start Out +
Ready Out Ready Out +
Fault Out Fault Out +
Ready In enable
+5V
Chart recorder
Output
J9
Peak sensing relay
Relay 1
Device Address
Relay 2
Relay 3
Relay 4
J10
J9
Syn Signal
J10
Signal Cable
02-001954-00
Sync cable for
ProStar 400
AutoSampler
0393516201
REC HI
REC
LOW
REC
GRD
INT HI
INIT
LOW
ProStar 701
INIT
GRD
Clear +ve
ProStar 320 UV-Detector
back plate
4
PEAK
A-GND
GND
5
ANALOG
3
+13VDC
ProStar 400 AutoSampler
2
ADVANCE
EVENT
MARK
D GRD
Detail
1
EVT MARK
AUTO
ZERO
NOTE : Lamp ON/OFF,
autozero can be
connected to Relay 2 & 3
respectively of the
ProStar 220/230/240
pump using the cable
02-001594-00.
INJECT
LAMP
ON/OFF
RACK
EXT WAVE
LOW
INPUTS
CONTROL I/O
OUTPUTS
COMM
PORT
CHASSIS
EXT
WAVE HI
Black -ve
39
ProStar 220/230/240 Pump (Master), 320
UV Detector, and 420/430 AutoSampler
Position sensing
switch of Rheodyne
manual injector is
connected to Start In
ProStar 220/230/240 Pump
1v
Data system
output 2AUFS
Start In Start In +
Ready In Ready In +
Fault In Fault In +
Gnd
Gnd
Start Out Start Out +
Ready Out Ready Out +
Fault Out Fault Out +
Ready In enable
+5V
1mV
Chart recorder
Output
J9
10V (switch)
10mV (switch)
Peak sensing relay
Relay 1
Device Address
Relay 2
Relay 3
Relay 4
J10
J9
Syn Signal
J10
Signal Cable
02-001954-00
Sync cable for
ProStar 420/430
AutoSampler
0393516101
REC HI
REC
LOW
REC
GRD
INT HI
ProStar 701
INIT
LOW
INIT
GRD
Clear +ve
EXT WAVE
LOW
ProStar 320 UV-Detector
back plate
ADVANCE
PEAK
A-GND
+13VDC
GND
D GRD
4
EVT MARK
ProStar 420/430 AutoSampler
Detail
3
INJECT
EVENT
MARK
NOTE : Lamp ON/OFF,
autozero can be
connected to Relay 2 & 3
respectively of the ProStar
220/230/240 pump using
the cable 02-001594-00.
2
RACK
AUTO
ZERO
1
INPUTS
LAMP
ON/OFF
OUTPUTS
P6
INPUTS
5
ANALOG
EXT
WAVE HI
P4
MARKER
RELAY
CHASSIS
COM
PORT
Black -ve
40
ProStar 220/230/240 Pump (Master),
310 UV Detector, and 420/430
AutoSampler
ProStar 220/230/240 Pump
1v
10V (switch)
Data system
output 2AUFS
10mV (switch)
Chart recorder
Output
J9
Peak sensing relay
Relay 1
Device Address
Relay 2
Relay 3
Relay 4
J10
J9
Syn Signal
J10
Signal Cable
02-001954-00
Start In Start In +
Ready In Ready In +
J9
Fault In Fault In +
Gnd
Gnd
Start Out Start Out +
Ready Out Ready Out + J10
Fault Out Fault Out +
Ready In enable
+5V
1v
10V (switch)
1mV
10mV (switch)
Data system
output 2AUFS
Chart recorder
Output
Peak sensing relay
Relay 1
Relay 2
Device Address
Relay 3
J9
Clear +ve
Syn Signal
4
PEAK
A-GND
+13VDC
GND
Detail
ProStar 420/430 AutoSampler
5
ANALOG
3
CHASSIS
2
ADVANCE
P6
INPUTS
1
EVT MARK
ProStar 310 UV-Detector
INJECT
J10
RACK
Sync cable for
ProStar 420/430
AutoSampler
0393516101
P4
MARKER
RELAY
ProStar 701
Relay 4
COM
POR
T
INPUTS
Position sensing
switch of
Rheodyne
manual injector is
connected to
Start In
OUTPUTS
Sync Cable Kit
03-91994890
Start In Start In +
Ready In Ready In +
Fault In Fault In +
Gnd
Gnd
Start Out Start Out +
Ready Out Ready Out +
Fault Out Fault Out +
Ready In enable
+5V
1mV
Black -ve
41
210/215/218 Pump (Master),
310 UV Detector, and 400 AutoSampler
INTGR
HI
INTGR
LOW
INTGR
GRD
CHASSIS
GRD
ANALOG
OUT
ANALOG
OUT
AUX
+5V
210/215/218 Pump
Position sensing
switch of Rheodyne
manual injector is
connected to Start In
Extension
R000815107
AUX
GND
STOP
D GND
HOLD
D GND
TRANSFER
1
D GND
INJECT
2
D GND
3
MARK
D GND
Shielded
R007200141
CONTROL I/O
10V (switch)
10mV (switch)
Chart recorder
Output
Peak Sensing relay
Relay 1
Relay 2
Device Address
Relay 3
ProStar 701
Shielded
R007200141
Relay 4
J9
SyN Signal
J10
INJECT
ADVANCE
PEAK
A-GND
EVT MARK
+13VDC
GND
4
RACK
Detail
ProStar 400 AutoSampler
3
INPUTS
ProStarr 310 UV-Detector
2
OUTPUTS
1
5
ANALOG
COMM
PORT
1v
1mV
Data system
output 2AUFS
CHASSIS
Sync cable for
ProStar 400
AutoSampler
0393516201
Start In Start In +
Ready In Ready In +
J9
Fault In Fault In +
Gnd
Gnd
Start Out Start Out +
Ready Out Ready Out + J10
Fault Out Fault Out +
Ready In enable
+5V
Shielded
R007200141
42
210/215/218 Pump (Master), 310 UV
Detector, and 420/430 AutoSampler
Extension
cable
R000815107
INTGR 1
HI
INTGR 1
LOW
INTGR 1
GRD
CHASSIS
GRD
ANALOG
OUT
ANALOG
OUT GRD
AUX
+5V
210/215/218 Pump
AUX
GND
Position sensing
switch of Rheodyne
manual injector is
connected to Start In
STOP
D GRD
HOLD
D GRD
TRANSFER
1
D GRD
INJECT
2
D GRD
3
MARK
D GRD
Shielded cable
R007200141
Sync cable for
ProStar 420/430
AutoSampler
0393516101
COM
PORT
Start In Start In +
Ready In Ready In +
Fault In Fault In +
Gnd
Gnd
Start Out Start Out +
Ready Out Ready Out +
Fault Out Fault Out +
Ready In enable
+5V
J9
J10
1v
Data system
output 2AUFS
1mV
Chart recorder
Output
Shielded cable
R007200141
10V (switch)
10mV (switch)
Peak sensing relay
Relay 1
Device Address
Relay 2
ProStar 701
Relay 3
Shielded cable
R007200141
Relay 4
J9
Syn Signal
J10
ANALOG
PEAK
+13VDC
CHASSIS
ADVANCE
EVT MARK
5
A-GND
INJECT
4
GND
INPUTS
ProStar 310 UV-Detector
3
RACK
P6
INPUTS
2
OUTPUTS
1
P4
MARKER
RELAY
Detail
ProStar 420/430 AutoSampler
43
210/215/218 Pump (Master), 310
UV Detector, and 410 AutoSampler
INTGR 1
HI
INTGR 1
LOW
INTGR 1
GRD
CHASSIS
GRD
ANALOG
OUT
ANALOG
OUT GRD
Extension
cable
R000815107
AUX
+5V
Position sensing
switch of
Rheodyne
manual injector
is connected to
Start In
210/215/218 Pump
AUX
GND
STOP
D GRD
HOLD
D GRD
TRANSFER
1
D GRD
INJECT
2
D GRD
3
MARK
D GRD
Shielded cable
R007200141
Start In Start In +
Ready In Ready In +
J9
Fault In Fault In +
Gnd
Gnd
Start Out Start Out +
Ready Out Ready Out + J10
Fault Out Fault Out +
Ready In enable
+5V
Sync cable for
ProStar 410
AutoSamplers
0393516301
1v
Data system
output 2AUFS
1mV
Chart recorder
Output
Shielded cable
R007200141
10V (switch)
10mV (switch)
Peak sensing relay
Relay 1
Relay 2
Device Address
Relay 3
ProStar 701
Shielded cable
R007200141
Relay 4
Syn
Signal
J9
J10
ADVANCE
PEAK
A-GND
ANALOG
EVT MARK
+13VDC
GND
CHASSIS
5
INJECT
4
RACK
3
INPUTS
ProStar 310 UV-Detector
2
OUTPUTS
1
Detail
P1 cable
P2 cable
ProStar 410 AutoSampler
44
210/215/218 Pump (Master), 340 UV
Detector, and 420/430 AutoSampler
Extension cable
R000815107
INTGR 1
HI
INTGR 1
LOW
INTGR 1
GRD
CHASSIS
GRD
ANALOG
OUT
ANALOG
OUT GRD
210/215/218 Pump
Position sensing
switch of Rheodyne
manual injector is
connected to Start In
STOP
D GRD
HOLD
D GRD
TRANSFER
1
D GRD
INJECT
2
NOTE:
AUX
+5V
AUX
GND
D GRD
Please refer to the
other detector
diagrams for
connection with
the other
AutoSamplers
3
MARK
D GRD
Shielded cable
R007200141
Shielded cable
R007200141
+
1
-
2
+
-
3
+
4
-
EVENT
+
-
5
+
-
ProStar 701
Shielded cable
R007200141
6
INPUTS
INJECT
ADVANCE
PEAK
EVT MARK
+13VDC
ProStar 340 UV-Detector
3
RACK
P6
INPUTS
2
OUTPUTS
1
P4
MARKER
RELAY
4
5
ANALOG
COM
PORT
AUTO
ZERO
CHASSIS
RECORDER
REMOTE
INT
1AU/V
A-GND
OUTPUT
GND
Sync cable for
ProStar 420/430
AutoSampler
0393516101
Detail
ProStar 420/430 AutoSampler
45
ProStar 220/230/240 Pump (Master), 320
UV Detector, and 410 AutoSampler
Position sensing
switch of Rheodyne
manual injector is
connected to Start In
ProStar 220/230/240 Pump
1v
Data system
output 2AUFS
Start In Start In +
Ready In Ready In +
Fault In Fault In +
Gnd
Gnd
Start Out Start Out +
Ready Out Ready Out +
Fault Out Fault Out +
Ready In enable
+5V
1mV
Chart recorder
Output
J9
10V (switch)
10mV (switch)
Peak sensing relay
Relay 1
Device Address
Relay 2
Relay 3
Relay 4
J10
J9
Syn Signal
J10
Signal Cable
02-001954-00
Sync cable for
ProStar 410
0393516301
REC HI
REC
LOW
REC
GRD
INT HI
ProStar 701
INIT
LOW
INIT
GRD
Clear +ve
ProStar410 AutoSampler
ProStar 320 UV-Detector
back plate
ADVANCE
PEAK
A-GND
EVT MARK
+13VDC
GND
D GRD
4
INJECT
P2
cable
Detail
3
INPUTS
P1
cable
EVENT
MARK
NOTE : Lamp ON/OFF,
autozero can be
connected to Relay 2 & 3
respectively of the ProStar
220/230/240 pump using
the cable 02-001594-00.
2
RACK
AUTO
ZERO
1
OUTPUTS
LAMP
ON/OFF
5
ANALOG
EXT WAVE
LOW
CHASSIS
EXT
WAVE HI
Black -ve
46
Download