advertisement
4 Initial connection and network search
1 Contents
TYDOM 3.0
1 Server
Mise en service
2 X3D USB key
Start the TYDOM 3.0 server, wait a few minutes for
the system to start up and for your router to assign
an IP address via DHCP.
3 Fastening plate
Multi-protocol home automation
server
4 Fastenings
7
You will find your server’s IP address using one
of the various equipment search tools on the
network, such as:
5 Power lead
Installation guide
6 Mains adapter
7 Installation guide
• “TYDOM HD Finder” is available on
www.deltadore.fr for a PC or MAC computer
6
• “FING” is available online for any computer, tablet
or smartphone
With this tool, the TYDOM’s IP address will appear on the network with the name:
Elitegroup Computeur Systems
1
4
5
INFO
PRODUIT
Open a web browser and type in the server
administration page as follows: https://<IP_
address>:8443 where <IP_address> is the
server’s IP address on the network.
3
www.deltadore.com
Note: If you are using “TYDOM HD Finder” to find
the server, you can open the administration page
directly by clicking on the displayed thumbnail.
The default password is “1234”. You will be able to
change the TYDOM 3.0 server’s IP address, run
updates or save the configuration.
Download and install the “Config Studio” and
“Design Studio” onto your Windows or iMac PC.
Check and download the available updates to get
the latest features and upgrades.
Note: do not shut down the server while the
installation is in progress.
Note: The automatic scanning of TYDOM 3.0 servers from the “TYDOM HD Finder” tool,
the “Config Studio” and “Design Studio”, requires
the installation of the “Bonjour” service.
This installation is automatically available as
applicable.
2
INPUT 100-240V~ 50-60 Hz 1,5A
3,42 A
OUTPUT : 19V
The connection quality of your product may be affected
due to changes on the IP architecture on which it
operates. These changes may involve (the list is not
exhaustive) a change in hardware, software update or
configuration operations, work on your operator’s equipment or any other multimedia devices such as tablets,
smartphones, etc.” Android™ and Google play are registered trademarks of Google Inc. IOS™ is a registered
trademark of Cisco Systems Inc. Due to the changes in
standards and hardware, the specifications laid down in
the text and the images in this document are only binding
subsequent to confirmation by our company.
5 Administrator password
5.1 Password entry (default: 1234)
-20°C / +70°C
-10°C / +40°C
IP 30
115 x 115 x 37 mm
The image is grey and will change to blue once you start entering your password.
Delta Dore hereby declares that the equipment complies with
the essential requirements and other relevant provisions of
R&TTE directive 1999/5/EC(radio).
5.2 Changing the password
2 Installation
2.1 Connections
If you press the image and hold it, the panel will
become larger; allowing you to change
the password.
2.1.1 Prerequisites
You will need a computer network
with an Internet connection that includes a router
with activated DHCP function, which is the case
for all ADSL units supplied by Internet service providers.
2.1.2 Connections
1 Connect the power lead
to the power unit.
2 Connect the power unit plug to the server.
3 Connect the power lead to the server’s network socket
(at the back) and to your computer network on the other side.
4 Connect the X3D USB key
5 Connect to a power outlet.
6 Press the key
.
We recommend that you keep TYDOM 3.0 away from any
equipment which could potentially transmit or receive a radio
signal.
1
2
5
4
The image is red and will change to blue only if the new password is entered correctly.
3
6 Remote access
6.1 Used ports
6
To access the TYDOM 3.0 server remotely, you will need a three-port (TCP) router: 8443, 8090 and
51023. The 8443 port is required for access to the server from an iPhone, iPad (HD version) and Android
phones as remote access. It is also used by “Config Studio” and “Design Studio”. Only “Config Studio”
and “Design Studio” for Windows and Mac use port 51023 for the communication socket receiving status
reports. The iPad Design Studio version uses port 8090 for this communication socket.
Note: To switch off the server, press
once and wait for the
indicator light to go out before disconnecting the power lead.
6.2 Alternative to using default ports
You can however select a different port to each port used by default. You will then have to indicate the applicable port for the application instead of the corresponding port. This is done when you want to connect
using Config Studio or Design Studio (see screenshot opposite).
3 Activation
The applicable syntax with “Config Studio” and “Design Studio” for Windows and Mac is the following:
<adresse_ip>?portws=<port_8443>&portsocket=<port_51023>
Before starting up TYDOM, you must activate your unit (you can anticipate this operation within a maximum
time frame of 48 hours).
Demandez l’activation du TYDOM 3.0
The applicable syntax for the “Design Studio” iPad application is the following:
<adresse_ip>?portws=<port_8443>&portsocket=<port_8090>
6.3 Summary table
• Téléchargez le fichier PDF à cette adresse : http://www.deltadore.fr/activationT3/
• Renseignez les champs du formulaire, communiquez notamment le numéro de série
de votre TYDOM 3.0 (Situé sous le boîtier de l’appareil ou sur le packaging,
12 caractères commençant par G6YE).
• Enregistrez le fichier sur votre ordinateur
123456789012
• Envoyez le fichier PDF complété à l’adresse indiquée : activation@deltadore.com
Default port
URL parameter URL
For all applications
8443
portws
For Windows and Mac applications
51023
portsocket
For iPad and Androïd Design Studio applications
8090
portsocket
6.4 Connecting
Enter the IP address (xxx.xxx.xxx.xxx), followed by the access port details, without spaces or any other
character. It is not necessary to indicate the ports if you have routed the default ports, in which case the
server’s IP address or DynDNS is enough.
Pour plus de renseignements, ou pour ajouter des fonctionnalités à votre appareil (protocoles, produits,
services ...)
In the example shown opposite, we are using port 44301 instead of port 8443 and port 44307 instead of
port 51023.
Note: Some ADSL unit models require the installation of an additional router. Please check the documentation on our site: www.deltadore.fr
6.5 Example
Remember to forward the ports to your Ethernet router:
For all applications
<ip distante>:44301
<ip box>:8443
For Windows and Mac applications
<ip distante>:44307
<ip box>:51023
For iPad and Androïd Design Studio
applications
<ip distante>:8090
<ip box>:8090
In this example, the syntax for access to Design Studio on
PC is for:<192.168.x.x>?portws=44301&portsocket=44307
Configuration
Run the software
Key to symbols
Config
studio
1
1
!
Start
connector
Locate
Change
Duplicate Remove
2
Select the TYDOM 3.0
to be configured
Find
Confirm
Module
not configured
Next
3
My sites
Connectors
Configure X3D dongle
Find X3D dongle
(this is to be done when the X3D
dongle is configured).
To add new modules jump to step 6.
Confirm
Description:
Properties:
COM port
Protocol: Delta Dore X3D
Category: USB interface
Interface: X3D USB dongle
USB interface
USB interface
7
Select the type of
DELTA DORE products
to associate
Lighting
X3D USB dongle
USB
Openings
Protocol: Delta Dore X3D
Category: USB interface
Interface: X3D USB dongle
Protocol: Delta Dore X3D
Category: USB interface
Interface: X3D USB dongle
Other control systems
Thermal receiver
Thermostat
Alarm
Transmitter
Run the USB
dongle connector
1
3
Found modules
2
Existing room
Type:
Label:
Light
Module configuration
Lighting
5
Room configuration
Specify the room where the
equipment is installed.
Site configuration
Specify the site to which the
equipment is connected.
Label:
Auxiliary light
Lighting
Max. capacity: 12 networks of 16 products
1 alarm - 20 transmitters
4
Equipment configuration
Specify the type of unit
controlled
Simple lighting
House
Auxiliary light
Auxiliary light
Associated locations
Night/sleep
Auxiliary light
Living room
Water
.....
Create
the equipment
Skip
6
Module configuration
Label:
Auxiliary light
Living room
.....
Saving
New room
Main
House
Sockets
Set the receiver(s) to association
standby mode
(refer to the user guide).
DELTA DORE
?
Example: Lighting
Service
The auxiliary light is
associated with the living room
Confirm
Run
the search
Site management
The auxiliary light module
is created
My house
Rooms
Equipment
1
Config Studio
Open the main page
Groups
Users
1
Multimedia
Rights
1
Control
system
Connectors
Locate
Change
Remove
Creation:
1 room
1 equipment unit
Current site:
My house
Auxiliary light
Planning
Infrastructure
Note: Before running a new search for
modules, set the receivers in association
standby mode (refer to the user guide)
Stat.
1
To change the access rights: create an administrator user
During configuration, a user is
automatically created, with restricted
access rights.
To access the edit and update modes,
an administrator user had to be
created.
To do this:
From the home page
Select the Users menu
Site management
Guest
1
Groups
1
Multimedia
Username:
Administrator
New user
Equipment
Control
system
Users
Rights
Enabled
Infrastructure
Stat.
2 Change the username
Navigation
MP3 player
Videophone
Rights
Scenario
Planning
Statistics
Histo. Alarms
Edit mode
User
Update
2
1
Planning
1 Add a new user
User management
Current site:
My house
Rooms
?
3 Unlock the menus
Control system*:
Perform advanced functions such as scenario, controller, etc.
Planning*:
Programme the control of your products depending on your lifestyle.
Design
studio
192.168.x.xx
4 Confirm
Guest
4
Update
Config Studio
3
Administrator
* Find out more on
www.deltadore.com
Use
Windows/Mac
software
Room selection
Display home page
Display rooms
in carousel mode
Living room
Thermostat
HD
Smartphone/Tablet application
Download the TYDOM HD application
1. Depending on your unit, connect to Google play or App Store
Smartphone
Navigation
Equipment
Installed
equipment
display
TYDOM
MP3 player
Videophone
Rights
Lighting
Scenario
Planning
Statistics
Alarms history
Edit mode
Adjustment area
for the selected module
User
Update
Select your
TYDOM 3.0
Edit mode
Unlock the menu rights:
Edit mode
Update
Multimedia*:
Configure your TV set, home cinema, IP camera, etc.
Run the software
- Edit mode
- Update
1
Design
studio
Number
of items
DELTA DORE
Add DELTA DORE
modules
X3D USB dongle
Run the search
Lighting network
6
Short label:
X3D USB dongle
Minimise
the window
DELTA DORE
FT232R USB UART (A7044SM9)
USB
Back
X3D USB dongle
Select the X3D dongle
Label:
X3D USB dongle
Home
page
Dune HD
Confirm
192.168.x.xx
8
4
Sonos
(default: 1234)
Configure a
DELTA DORE module
Sub-menu TYDOM 3.0
Infrared
Config Studio
USB
Add
KNX
Password:
5
Close
the window
2. Find and download the free “TYDOM HD” application
3. Enable the WIFI connection on your smartphone or tablet.
4 Configure the application.
Ê Open the application.
Ë Enter the server's IP address
Ì Enter your password.
Í Press the "Connect" button.
Î The home screen appears. You are now connected
Tablet
Update
TYDOM 3.0
2
1
Server update and backup
procedure
OK
OK
http://www.deltadore.com
4
3
5
Tydom Finder
PC
Tydom Finder
MAC
www.deltadore.com
7
1
1
2
8
9
1 The
2 TYDOM
3 4 3.0
5 server
6 7 and
8 a 9computer
10 111must
122 be3 con4 5
nected to the same local network with Internet access.
1 2 3 4 5 6
2 Go
3 to:4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7
http://www.deltadore.com
3 Open
4 5the 6link 7"Tydom
8 9Finder"
10 11
12 download section
in the
1 2 3 4 5 6 7 8
and select the required version.
212
11 22 33 44 55 Download
66 77 88and
99install
10
10111
11
123 4 5
the
software
Tydom Finder
6
7
8
TydomFinder.exe
TydomFinder Installation
Tydom Finder
10
6 Open
7 8 the9Tydom
10 11
12 application
Finder
7 Select
8 9 your
10 server's
11 12 thumbnail.
8 Enter
9 10the11administrator
12
password
(default: 1234) and confirm.
9 10
11 the
12"update" menu
Select
When
an
9 10 11 12 update is available
Click on “download updates"
Backup
After configuring your TYDOM 3.0, we recommend that you do a backup at a different physical location (network PC,
network-attached storage (NAS) etc.).
Backup settings
1
3
2
5
4
1 Select
2 3 your
4 server's
5 6 thumbnail.
7 8 9 10 11 12
1
1
2 Enter
3 4the5administrator
6 7 8 password
9 10 11
12 1234) and confirm.
(default:
1
2
3 Select
4 5 the
6 "Backup
7 8 settings"
9 10 11
12
menu
1
2
3
4 Click
5 6on the
7 "Add
8 9a network-attached
10 11 12
server"
2
3
4
5 Enter
6 7the8network-attached
9 10 11 12 server settings. Click on “Add”
A backup will be performed automatically every week on Sunday night.
Backup and recovery
1
1 Select
2 3 the
4 “Backup
5 6 and
7 recovery”
8 9 10
11 12
menu
2
1
1
2
2
6
3 4 5and6recovery
7 8 menu
9 10 11 12
Backup
Ê Generate a new backup -> Launch a manual backup
Generate a new backup (without the logs)
Send a backup
Restore factory settings
Ë Action on the selected backup
Rename
Delete
Download
Reset
Download