TRANSMISSION AND DISTRIBUTION III Year / V Semester Subject code : EE T 53 SYLLABUS EE T53 TRANSMISSION AND DISTRIBUTION Objectives: To understand the structure of electric supply system and different types of distribution systems, To gain the knowledge of line parameters, skin effect, proximity effect and corona in transmission lines. To learn the performance evaluation of different types of transmission lines by calculating transmission efficiency and voltage regulation. To study on the selection of cables and insulators for specific applications and To gain a thorough knowledge of the design aspects of rural and town electrification schemes, HVDC and FACTS technology. UNIT I: DISTRIBUTION SYSTEMS Structure of electric power systems-one Line Diagram-generation, transmission and distribution Systems-comparison of distribution systems–radial and ring –two wire dc, ac single phase and three phase systems–current and voltage calculations in distributors with concentrated and Distributed loads – Kelvin’s law for the design of feeders and its limitations. UNIT II: TRANSMISSION LINE PARAMETERS Resistance, inductance and capacitance of single and three phase transmission linessymmetrical and unsymmetrical spacing– transposition-single and double circuitsstranded and bundled conductors-application of self and mutual GMD–Skin and Proximity effect-inductive interference-Coronacharacteristics. UNIT III: PERFORMANCE OF TRANSMISSION LINES Development of equivalent circuits for short, medium and long lines–efficiency and regulation- Attenuation constant and phase constant- surge impedance loading –power circle diagrams for sending and receiving ends-transmission capacity, steady state stability limit–voltage control of lines -shunt and series compensation. UNIT IV: INSULATORS AND CABLES Insulators–types and comparison–voltage distribution in string insulator–string efficiency–Methods of improving string efficiency–Stress and sag calculations–effect of wind and ice– supports at different levels– stinging chart-cables– types–capacitance of cables–insulation resistance - dielectric stress and grading- dielectric loss- thermal characteristics- capacitance of three core cables. UNIT V: RECENT TRENDS IN TRANSMISSION Design of rural distribution, planning and design of town electrification schemes– comparison of EHVAC & HVDC system– economic distance for HVDC–terminal equipment for HVDC systems–description of DC transmission system–planningadvantages-interconnection of HVDC & AC systems–Introduction to FACTS technology STRUCTURE OF THE POWER SYSTEM DISTRIBUTION SYSTEM i) Feeders. (ii) Distributor (iii) Service mains ( CLASSIFICATION OF DISTRIBUTION SYSTEMS (i) Nature of current (iii) Scheme of connection (ii) Type of construction A.C. Distribution D.C Distribution Typical Primary Distribution System Typical Secondary Distribution System CONNECTION SCHEMES OF DISTRIBUTION SYSTEM (i) a single line diagram of a radial system for d.c. distribution •a single line diagram of radial system for a.c. Distribution (i) Single line diagram of a radial system for D.C. Distribution (ii) Single line diagram of radial system for A.C. Distribution Single line diagram of ring main system for A.C. distribution Advantages : (a) There are less voltage fluctuations at consumer’s terminals. (b) The system is very reliable as each distributor is fed via two feeders Single line diagram of Interconnected system Advantages : It increases the service reliability Any area fed from one generating station during peak load hours can be fed from the other generating station. This reduces reserve power capacity and increases efficiency of the system. REQUIREMENTS OF A DISTRIBUTION SYSTEM Proper voltage Availability of power on demand. Reliability Kelvin’s Law and its Limitations The cost of conductor material is generally a very considerable part of the total cost of a transmission line. Therefore, the determination of proper size of conductor for the line is of vital importance. The most economical area of conductor is that for which the total annual cost of transmission line is minimum. This is known as Kelvin’s Law after Lord Kelvin who first stated it in 1881. The total annual cost of transmission line can be divided broadly into two parts viz., annual charge on capital outlay and annual cost of energy wasted in the conductor. (i) Annual charge on capital outlay. This is on account of interest and depreciation on the capital cost of complete installation of transmission line. In case of overhead system, it will be the annual interest and depreciation on the capital cost of conductors, supports and insulators and the cost of their erection. Now, for an overhead line, insulator cost is constant, the conductor cost is proportional to the area of Xsection and the cost of supports and their erection is partly constant and partly proportional to area of X section of the conductor. Therefore, annual charge on an overhead transmission line can be expressed as : Annual charge = P1 + P2 a ...(i) Where, P1 and P2 are constants and a is the area of X-section of the conductor. (ii) Annual cost of energy wasted. This is on account of energy lost mainly in the conductor due to I2 R losses. Assuming a constant current in the conductor throughout the year, the energy lost in the conductor is proportional to resistance. As resistance is inversely proportional to the area of X section of the conductor, therefore, the energy lost in the conductor is inversely proportional to area of X-section. Thus, the annual cost of energy wasted in an overhead transmission line can be expressed as : Annual cost of energy wasted = P3 / a ...(ii) Where, P3 is a constant. Total annual cost, C = exp. (i) + exp. (ii) = (P1 + P2 a) + P3 / a ∴ C = P1 + P2 a + P3 / a ...(iii) In exp. (iii), only area of X-section a is variable. Therefore, the total annual cost of transmission line will be minimum if differentiation of C w.r.t. a is zero. Variable part of annual charge = Annual cost of energy wasted Graphical illustration of Kelvin’s law Limitations of Kelvin’s law. (i) It is not easy to estimate the energy loss in the line without actual load curves, which are not available at the time of estimation. (ii) The assumption that annual cost on account of interest and depreciation on the capital outlay is in the form P1 + P2a is strictly speaking not true. For instance, in cables neither the cost of cable dielectric and sheath nor the cost of laying vary in this manner UNIT –II Transmission Line Parameters INSULATORS