Uploaded by vengatesh.uth

Integration Baseband 5212 5216 Ericsson

advertisement
22/9/2017
Help to be great :): Integration Baseband 5212 / 5216 Ericsson Manual Method
Tuesday, June 13, 2017
Search
Integration Baseband 5212 / 5216 Ericsson Manual Method
Integration Baseband 52xx Ericsson Manual Method
Tools
Search
Blog Post
▼ 2017 (2)
▼ June (2)
1. Web Browser (recommended use Firefox or Chrome)
2. Latest Moshell or minimum Moshell 17.0c ( Moshell 17.0e )
3. RJ-45 LAN cable straight
4. SFTP aplication ( Download Here )
5. Software 17A SW R5E74 ( Download Here ) 706 MB
Baseband Configuration Files
1. RBS Summary Script
2. Site Basic Script
3. Site Equipment Script
4. Transport Network Script
5. Radio Network Script
You can download here
Integration Baseband 5212 /
5216 Ericsson Manual M...
Easy Step Commisioning and
Integration LTE DUS / D...
► 2015 (3)
Top Post
How To Install Latest Moshell |
Easy Step Install Moshell 16.0v /
Moshell 17.0e
1. Power Up Baseband 521x
Connect Laptop to port LMT Baseband using RJ45 cable straight
IP Laptop Setting 169.254.2.1
Firewall and antivirus should be disabled in the local PC
Setting SFTP Server
http://kaccunk.blogspot.com.co/2017/06/integration-baseband-52xx-ericsson.html
1/7
22/9/2017
Help to be great :): Integration Baseband 5212 / 5216 Ericsson Manual Method
- IpAddress Baseband : 169.254.2.1
- User : ftp
- Password : ftp
- Root path : Directory to Software 17A SW R5E74 and script folder
2. Open IE/Chrome/Firefox
Log in to AutoIntegration Web GUI :
https://169.254.2.2
- Host : 169.254.2.1 (IP Laptop)
- Username : ftp
- Password: ftp
- Site Installation File: /<RBS_Summary>.xml
3. Press button ‘Download Files’ until download complete.
Proses download will appear in AutoIntegration log
http://kaccunk.blogspot.com.co/2017/06/integration-baseband-52xx-ericsson.html
2/7
22/9/2017
Help to be great :): Integration Baseband 5212 / 5216 Ericsson Manual Method
After download files complete, press button “Integrate” for starting integration. Baseband will restart before
integration, process started (estimation 15 minutes).
Make sure transmission cable already connect to TRM Equipment (mandatory)
After Auto Integration complete, in AutoIntegration Web
GUI will appear “Welcome to RBS”.
Open Moshell, log in to RBS using default IP 169.254.2.2.
If Integration process failed/error, Baseband will automatically restore to factory setting. Details error check in
Emergency Access https://169.254.2.2/ea.html
http://kaccunk.blogspot.com.co/2017/06/integration-baseband-52xx-ericsson.html
3/7
22/9/2017
Help to be great :): Integration Baseband 5212 / 5216 Ericsson Manual Method
4. Running Transport Network & Radio Network script via Netconf with command below.
!ssh -o PubKeyAuthentication=no -o UserKnownHostsFile=/dev/null -o ForwardX11=no -p <port_netconfssh>
rbs@169.254.2.2 -s netconf < filename.xml
Example :
!ssh -o PubKeyAuthentication=no -o UserKnownHostsFile=/dev/null -o ForwardX11=no -p 830 rbs@169.254.2.2
-s netconf < /home/enurnug/BB5212/Test/Transport_Local.xml
Another command maybe usefull
› Chek mac address router: mcc Router=vr_Traffic3G show arp-cache
› Ping test: mcc Router=Traffic ping 10.211.38.86 --count 2 --packetsize 1000
› Make CV: acc BrmBackupManager createBackup or cvmk <backup name>
› Delete CV: acc BrmBackupManager deleteBackup or cvrm <backup name>
› Cvset & node restart on startable CV: acc BrmBackup=XX restore or cvre <backup name>
› Restart Node: acc FieldReplaceableUnit=1 restartUnit
17 comments:
Margarita Morfin July 17, 2017 at 2:41 PM
Hello, Where can I get the Baseband Configuration Files?
1. RBS Summary Script
2. Site Basic Script
3. Site Equipment Script
4. Transport Network Script
5. Radio Network Script
Reply
http://kaccunk.blogspot.com.co/2017/06/integration-baseband-52xx-ericsson.html
4/7
22/9/2017
Help to be great :): Integration Baseband 5212 / 5216 Ericsson Manual Method
Reply
Replies
Man Behind The Signal
July 31, 2017 at 7:30 PM
Hi, sorry for late response.
You can ask script to your Ericsson SPV.
If you wanna example, i'll upload it soon...
Unknown September 9, 2017 at 9:59 PM
Hellp Bro, When the steps you outlined as been followed, Can I say integration has been
completed? If No, what other things needs to be done.
Thanks in advance
Man Behind The Signal
September 11, 2017 at 7:10 AM
Hi bro,
yes, Integration for Endsite has done, then you must request for integration ( RNC side ). :)
Reply
Sirait Mohan August 2, 2017 at 9:46 PM
Thanks udah share Gan... Good Luck
Reply
Anonymous August 8, 2017 at 8:27 PM
Is it compulsory to set up sftp server for login using browser because I tried but not able to login BB
using browser
Can you pls explain setting up sftp server in detail(like options button)
Reply
Replies
Man Behind The Signal
August 24, 2017 at 3:32 AM
Hi bro,
Setting sftp is mandatory for enabling upgrade baseband software, not for login BB.
Please re-check your firewall or antivirus, try to ping BB.
Or you can reset BB first using emergency acces before integrate it. ( If Baseband already
integrated its cant login using browser )
Reply
Unknown September 8, 2017 at 5:54 AM
Hello Experts, Whats the file path to be inputed on the GUI before files re downloaded? Thanks in
advance.
Reply
Replies
Man Behind The Signal
September 11, 2017 at 7:23 AM
I'm still noobs -__You can use any folder in any drive for rootpath ( please re-check name and the path )
- Root path : Directory to Software 17A SW R5E74 and script folder
Adeniran September 15, 2017 at 9:55 AM
Thanks Bro! Appreciate!
Can you please share with me useful onsite commands that I can run incase I need to
troubleshoot. Also, Can license be loaded on site? If yes, how? I also need the script to
activate node after loading TN and rn script.
Thanks in advance
http://kaccunk.blogspot.com.co/2017/06/integration-baseband-52xx-ericsson.html
5/7
22/9/2017
Help to be great :): Integration Baseband 5212 / 5216 Ericsson Manual Method
Reply
Unknown September 8, 2017 at 10:53 AM
Hello Experts,
Will integration be completed if transmission is not connected to BB? Running a trial but integration gets
completed at 70% and wont go past to 100%
Will appreciate response
Reply
Replies
Man Behind The Signal
September 11, 2017 at 7:20 AM
No problem bro, some BB are completed at 70% and wont go past to 100%.
You can always check via moshell, open Moshell -> log in to RBS -> if MO already load ->
Wellcome you're done :)
Unknown September 15, 2017 at 9:51 AM
Thanks Bro! You Spot-on!
Reply
Anonymous September 11, 2017 at 1:59 PM
Hi good day.
Login to download the software 17A but the page indicates "not found", would be so kind to re-upload
this software please.
Another query, do you know how to configure GSM within baseband?
Thank you very much for your information.
Reply
Adeniran September 16, 2017 at 1:59 AM
This comment has been removed by the author.
Reply
Adeniran September 21, 2017 at 3:30 AM
Can someone share with me how to configure external alarms on Ericsson baseband?
Reply
Replies
Anonymous September 21, 2017 at 12:42 PM
Hello, write to this mail and I can guide you a little more.
polanco.cri@gmail.com
I wait your answer
Reply
Enter your comment...
Comment as:
Publish
Select profile...
Preview
http://kaccunk.blogspot.com.co/2017/06/integration-baseband-52xx-ericsson.html
6/7
22/9/2017
Help to be great :): Integration Baseband 5212 / 5216 Ericsson Manual Method
Home
Older Post
Subscribe to: Post Comments (Atom)
Pageviews
9 3 5 4
Awesome Inc. theme. Theme images by 5ugarless. Powered by Blogger.
http://kaccunk.blogspot.com.co/2017/06/integration-baseband-52xx-ericsson.html
7/7
Download