Component & Cladding - First floor walls Step 1: Basic Wind speed: 140mph Step 2: Kd = 0.85 Exposure Category B Kzt = 1 Enclosure classification: Partially enclosed Internal pressure coefficient: GCpi = ±0.55. Step 3: *Kz = 0.7 (h = 20.5ft) 4ft 18.5ft *Mean Roof height = 18.5 + 4/2 = 20.5ft Step 4: Velocity Pressure qh qh = 0.00256 kzkztKdV2 = 0.00256(0.7)(1)(0.85)(140)2 = 29.85 lb/ft2 H 0-15 15-20 Kz 0.7 0.7 qz 29.85 29.85 Step 5: External pressure coefficient Cp *Wall 1: Effective length = 15.54 ft (Eff. Length is taken from perforated shear wall design) Height of wall = 9.33ft Effective area = 15.54 x 9.33 = 145 sq.ft. GCp = +0.8 & -1.0 for 5 zone; -0.9 for 4 zone. Component & Cladding - First floor walls Step 6: Wind Pressure, For zone 5 Positive internal pressure P = 29.85[ +0.8 – (+0.55)] = 7.4625 lb/ft2. P = 29.85 [-1 – (+0.55)] = - 46.2675 lb/ft2 Negative Internal Pressure P = 29.85 [ +0.8 – ( -0.55)] = 40.29 lb/ft2. P = 29.85 [ -1.0 – ( -0.55)] = -13.4325 lb/ft2. For zone 4 Positive internal pressure P = 29.85[ +0.8 – (+0.55)] = 7.4625 lb/ft2. P = 29.85 [-0.9 – (+0.55)] = - 43.2825 lb/ft2 Negative Internal Pressure P = 29.85 [ +0.8 – ( -0.55)] = 40.29 lb/ft2. P = 29.85 [ -0.9 – ( -0.55)] = -10.4475 lb/ft2. *Wall 2: Effective length = 6 ft (Eff. Length is taken from perforated shear wall design) Height of wall = 9.33ft Effective area = 6 x 9.33 = 55.98 sq.ft. Component & Cladding - First floor walls GCp = +0.83 & -1.18 for 5 zone; -0.98 for 4 zone. Wind Pressure, P For zone 5 Positive internal pressure P = 29.85[ +0.83 – (+0.55)] = 8.358 lb/ft2. P = 29.85 [-1.18 – (+0.55)] = - 51.64 lb/ft2 Negative Internal Pressure P = 29.85 [ +0.83 – ( -0.55)] = 41.2 lb/ft2. P = 29.85 [ -1.18 – ( -0.55)] = -18.8 lb/ft2. For zone 4 Positive internal pressure P = 29.85[ +0.83 – (+0.55)] = 8.358 lb/ft2. P = 29.85 [-0.98 – (+0.55)] = - 45.68 lb/ft2 Negative Internal Pressure P = 29.85 [ +0.83 – ( -0.55)] = 41.2 lb/ft2. P = 29.85 [ -0.98 – ( -0.55)] = -12.835 lb/ft2. *Wall 3: Effective length = 5.67 ft Component & Cladding - First floor walls (Eff. Length is taken from perforated shear wall design) Height of wall = 9.33ft Effective area = 5.67 x 9.33 = 53 sq.ft GCp = +0.83 & -1.18 for 5 zone; -0.98 for 4 zone. Wind Pressure, P For zone 5 Positive internal pressure P = 29.85[ +0.83 – (+0.55)] = 8.358 lb/ft2. P = 29.85 [-1.18 – (+0.55)] = - 51.64 lb/ft2 Negative Internal Pressure P = 29.85 [ +0.83 – ( -0.55)] = 41.2 lb/ft2. P = 29.85 [ -1.18 – ( -0.55)] = -18.8 lb/ft2. For zone 4 Positive internal pressure P = 29.85[ +0.83 – (+0.55)] = 8.358 lb/ft2. P = 29.85 [-0.98 – (+0.55)] = - 45.68 lb/ft2 Negative Internal Pressure P = 29.85 [ +0.83 – ( -0.55)] = 41.2 lb/ft2. Component & Cladding - First floor walls P = 29.85 [ -0.98 – ( -0.55)] = -12.835 lb/ft2. *Wall 4: Effective length = 7.85 ft (Eff. Length is taken from perforated shear wall design) Height of wall = 9.33ft Effective area = 7.85 x 9.33 = 73.24 sq.ft GCp = +0.82 & -1.15 for 5 zone; -0.95 for 4 zone. Wind Pressure, P For zone 5 Positive internal pressure P = 29.85[ +0.82 – (+0.55)] = 8.059 lb/ft2. P = 29.85 [-1.15 – (+0.55)] = - 50.74 lb/ft2 Negative Internal Pressure P = 29.85 [ +0.82 – ( -0.55)] = 40.89 lb/ft2. P = 29.85 [ -1.15 – ( -0.55)] = -17.8 lb/ft2. For zone 4 Positive internal pressure P = 29.85[ +0.82 – (+0.55)] = 8.058 lb/ft2. P = 29.85 [-0.95 – (+0.55)] Component & Cladding - First floor walls = - 44.68 lb/ft2 Negative Internal Pressure P = 29.85 [ +0.82 – ( -0.55)] = 40.89 lb/ft2. P = 29.85 [ -0.95 – ( -0.55)] = -11.935 lb/ft2. *Wall 5: Effective length = 9.326 ft (Eff. Length is taken from perforated shear wall design) Height of wall = 9.33ft Effective area = 9.326 x 9.33 = 87 sq.ft GCp = +0.8 & -1.1 for 5 zone; -0.92 for 4 zone. Wind Pressure, P For zone 5 Positive internal pressure P = 29.85[ +0.8 – (+0.55)] = 7.45 lb/ft2. P = 29.85 [-1.1 – (+0.55)] = - 49.24 lb/ft2 Negative Internal Pressure P = 29.85 [ +0.8 – ( -0.55)] = 40.29 lb/ft2. P = 29.85 [ -1.1 – ( -0.55)] = -16.48 lb/ft2. For zone 4 Component & Cladding - First floor walls Positive internal pressure P = 29.85[ +0.8 – (+0.55)] = 7.45 lb/ft2. P = 29.85 [-0.95 – (+0.55)] = - 44.78 lb/ft2 Negative Internal Pressure P = 29.85 [ +0.8 – ( -0.55)] = 40.29 lb/ft2. P = 29.85 [ -0.95 – ( -0.55)] = -11.935 lb/ft2. *Wall 6: Effective length = 3.51ft (Eff. Length is taken from perforated shear wall design) Height of wall = 9.33ft Effective area = 3.51 x 9.33 = 32.8 sq.ft GCp = +0.9 & -1.2 for 5 zone; -1.0 for 4 zone. Wind Pressure, P For zone 5 Positive internal pressure P = 29.85[ +0.9 – (+0.55)] = 10.45 lb/ft2. P = 29.85 [-1.2 – (+0.55)] = - 52.24 lb/ft2 Negative Internal Pressure P = 29.85 [ +0.9 – ( -0.55)] Component & Cladding - First floor walls = 43.29 lb/ft2. P = 29.85 [ -1.2 – ( -0.55)] = -19.48 lb/ft2. For zone 4 Positive internal pressure P = 29.85[ +0.9 – (+0.55)] = 10.45 lb/ft2. P = 29.85 [-1.0 – (+0.55)] = - 46.28 lb/ft2 Negative Internal Pressure P = 29.85 [ +0.9 – ( -0.55)] = 43.29 lb/ft2. P = 29.85 [ -1.0 – ( -0.55)] = -13.435 lb/ft2. *Wall 7: Effective length = 10ft (Eff. Length is taken from perforated shear wall design) Height of wall = 9.33ft Effective area = 10 x 9.33 = 93.3 sq.ft GCp = +0.8 & -1.15 for 5 zone; -0.93 for 4 zone. Wind Pressure, P For zone 5 Positive internal pressure P = 29.85[ +0.8 – (+0.55)] = 7.45 lb/ft2. Component & Cladding - First floor walls P = 29.85 [-1.1 – (+0.55)] = - 49.24 lb/ft2 Negative Internal Pressure P = 29.85 [ +0.8 – ( -0.55)] = 40.29 lb/ft2. P = 29.85 [ -1.1 – ( -0.55)] = -16.48 lb/ft2. For zone 4 Positive internal pressure P = 29.85[ +0.8 – (+0.55)] = 7.45 lb/ft2. P = 29.85 [-0.95 – (+0.55)] = - 44.78 lb/ft2 Negative Internal Pressure P = 29.85 [ +0.8 – ( -0.55)] = 40.29 lb/ft2. P = 29.85 [ -0.95 – ( -0.55)] = -11.935 lb/ft2.