IT Certification Guaranteed, The Easy Way! Exam : NS0-509 Title : NetApp Certified Implementation Engineer - SAN, ONTAP Vendor : Network Appliance Version : V12.75 1 IT Certification Guaranteed, The Easy Way! QUESTION NO: 1 Exhibit: Referring to the exhibit, you have SAN LUNs on an AFF A700s and are asked to test an SSD shelf stack failure. What is the maximum allowed number of failed paths per controller to shelf stack before a storage failover occurs? A. 1 B. 3 C. 2 D. 4 Answer: Go with 4 QUESTION NO: 2 Exhibit: 2 IT Certification Guaranteed, The Easy Way! Referring to the exhibit, which two pairs of ports are currently configurable as FC SAN LIFs? (Choose two.) A. 01b, 0h B. 01a, 0g C. 01a, 0h D. 01b, 0g Answer: A & D QUESTION NO: 3 Exhibit: Referring to the exhibit, which FC LIF would cause a path failure on a host connecting to a LUN? A. fcp_sanluns01prod02p0e B. fcp_sanluns01prod02p0g C. fcp_sanluns01prod02p0g D. fcp_sanluns0lptodOlp0e Answer: ?? QUESTION NO: 4 Exhibit: 3 IT Certification Guaranteed, The Easy Way! A Linux host cannot discover a newly provisioned LUN. Referring to the exhibit, what would be the cause of the problem? A. The IUN ID Is Incorrect. B. The host's MPIO feature is not enabled. C. The Initiator group is misconfigured. D. The host's IP address is misconfigured. Answer: C QUESTION NO: 5 A customer has an existing 8-node cluster that consists of six FAS2650 nodes and two FAS2554 nodes. The customer wants to expand the cluster by adding two AFF A220 nodes. Which resource would be used to determine whether this configuration is supported? A. Interoperability Matrix Tool (IMT) B. Config Advisor C.OneCollect D Hardware Universe (HWU) Answer: D QUESTION NO: 6 Exhibit: 4 IT Certification Guaranteed, The Easy Way! The exhibit shows the Lun show command output for the oradata oraFinProd_l LUN. Which two statements are correct about the LUN'? (Choose two.) A. The LUN Is thick provisioned. B. The LUN supports SCSI Thin unmap. C. The LUN type is Windows. D. The LUN is thin provisioned. Answer: B,D QUESTION NO: 7 Exhibit: 5 IT Certification Guaranteed, The Easy Way! An administrator is configuring FCoE on Cisco Nexus switches for a new AFF A200 ONTAP cluster. The administrator executes the commands shown in the exhibit to create the necessary network configuration. Which VLAN is responsible for controlling the FCoE traffic on the new interface? A. 0 B. 3011 C. 23 D. 11 Answer: B QUESTION NO: 8 A storage administrator created a LUN using two ports on a storage system. Later, additional LUNs were added to the same node as the original LUN. After a while, the performance of the original LUN dropped beyond an acceptable level. What would you advise to remedy the Issue? A. Add an additional switch between the hosts and cluster. B. Add new LIFs on unused ports. C. Add new LIFs on the used ports. D. Reduce the queue depth on the used ports. Answer: B Queue depth is the number of I/O requests (SCSI commands) that can be queued at one time on a storage controller. Each I/O request from the host's initiator HBA to the storage controller's target adapter consumes a queue entry. Typically, a higher queue depth equates to better performance. QUESTION NO: 9 Exhibit: 6 IT Certification Guaranteed, The Easy Way! You have a LUN owned by Node 01 and mapped using the default Selective LUN Map (SLM) configuration. You want to enable your host to access this LUN and facilitate future maintenance. Which best-practice zone configuration accomplishes this task? A. Zone 1: HBA 0, LIF_1, LIF_3, LIF_5 and LIF_7 Zone 2: HBA 1, LIF_2, LIF_4, LIF_6 and LIF_8 B. Zone 1: HBA 0, HBA 1, LIF_1, LIF_2, LIF_3, LIF_4, LIF_5, LIF_6, LIF_7, LIF_8 C. Zone 1: HBA 0, LIF_1, LIF_3 Zone 2: HBA 1, LIF_2, LIF_4 D. Zone 1: HBA 0, HBA 1, LIF_1, LIF_2, L1F_3, LIF_4 Answer: A QUESTION NO: 10 Exhibit: 7 IT Certification Guaranteed, The Easy Way! You are adding a boot LUN for a new server. The server uses FCP attached through a CN A. The ONTAP cluster is also attached to the same fabric by way of UTA2. You configure the zoning for the fabric as shown in the exhibit. You discover that the server cannot see its boot LUN. What is the problem with your zoning configuration? A. The zone set must have the same name as the zone. B. The zone was not activated. C. The zone used a wrong zone ID. D. The WWPN for the NetApp LIF is incorrect. Answer: D QUESTION NO: 11 An administrator wants to implement FCoE for connectivity of an AFF A200 using VLAN 3011 for fabric traffic across VSAN 11. When configuring the Nexus switches for FCoE connectivity, which two actions are required? (Choose two.) A. Create a new virtual FC interface and bind the physical interface to it. B. Add the virtual interface to the VSAN. C. Create a port channel and add all of the physical network ports that will have FCoE LIFs. D. Add the adapter MAC address to the network port configuration where the node is connected. Answer: B,C QUESTION NO: 12 You need to move a LUN non-disruptively from an AFF A200 HA pair to an AFF A700 HA pair within the same 4-node cluster using the steps shown below. 1. Scan the host OS to discover all paths to the LUN. 2. Execute the lun move command to move the LUN to the AFF A/00 HA pair. 3. Remove the AFF A200 HA pair from the reporting-nodes list. 4. Add the AFF A700 HA pair to the reporting-nodes list. What is the correct sequence in performing, these steps? A.1,2,3.4 B.4.1,2,3 C.4,3.2.1 D. 3, 2, 1,4 Answer: B 8 IT Certification Guaranteed, The Easy Way! QUESTION NO: 13 An SVM's LUN setup needs to have LIFs that are configured for FC access and iSCSI access. The administrator will also be using NetApp Virtual Storage Console. In this scenario, which three types of LIFs are required? (Choose three.) FC LIFs A. management LIFs B. iSCSI data LIFs C. NAS data LIFs Incorrect D. intercluster LIFs Incorrect Answer: A,B, ? I think the answer is FC LIFs, ISCSI LIFs & management LIFs QUESTION NO: 14 Exhibit: Referring to the exhibit, what happens when you change the type for port 1a from target to initiator? A. The port type for 1a changes to initiator, and you must reboot the controller for the changes to take effect. B. You receive an error message that you must take ports 1a and 1b offline before you can change the type. C. You receive an error message that you must take the port 1a offline before you can change the type. D. The port type for 1a and 1b changes to initiator, and you must reboot the controller for the changes to take effect. Answer: I think D because of a shared ASIC https://kb.netapp.com/app/answers/answer_view/a_id/1001031/~/what-are-unified-target-adapter-%28uta2%29%2Fcnaports-and-how-to-configure-them%3F- QUESTION NO: 15 An administrator is planning a hardware refresh and data migration from a Data ONTAP 7.3 system to new AFF A300 cluster that is using ONTAP 9.0. The 7 Mode system only serves FC LUNs to a Windows 2012Rs server cluster that needs to remain connected after migration Referring to the scenario, which method would be used for the LUN migration. A. Unified Host Utility Kit B. 7-Mode Transition Tool (7MTT) C. Foreign LUN import (FLI) D. Oncommand system Manager Answer: B 9 IT Certification Guaranteed, The Easy Way! QUESTION NO: 16 You are setting up FC ports and must configure the speeds for both the SAN and the host ports. In this scenario, which statement is correct? A. Set the target port speed higher than the switch port speed. B. Set the target port speed to auto-negotiation. C. Set the target port speed to match the switch port speed. D. Set the target port speed lower than the switch port speed. Answer: C QUESTION NO: 17 Exhibit: Referring to the exhibit, which two statements are true? (Choose two.) A. The volume guarantee has no effect. B. LUN overwrites are guaranteed. C. The LUN might run out of space. D. The LUN space reservation has no effect. Answer: C & D If a space-reserved LUN is created in a none-guaranteed volume, the LUN behaves the same as a non-spacereserved LUN. This is because a none-guaranteed volume has no space to allocate to the LUN; the volume itself can only allocate space as it is written to, due to its none guarantee. Therefore, creating a space-reserved LUN in a none-guaranteed volume is not recommended; employing this configuration combination might provide write guarantees that are in fact impossible. QUESTION NO: 18 An administrator wants to design an NVMe solution to connect Linux hosts to an ONTAP cluster. The proposed solution uses two Cisco MDS 9396T switches for each fabric in a top-of-rack design. In this scenario, which statement is true? A. Asymmetric Namespace Access requires ONTAP 9.4 and higher. B. NVMe solutions require heterogeneous multiple switch fabrics. C. N_Port ID virtualization (NPIV) must be enabled on all switches. D. A middle-of-rack design is required. Answer: C https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanconf%2FGUID-9CD2611E-7081-41258418-D223C407B86E.html QUESTION NO: 19 An administrator reviews the Upgrade Advisor before performing an upgrade of their ONTAP cluster. What information is detailed in the report? (Choose two.) A. pre-upgrade checks B. performance metrics 10 IT Certification Guaranteed, The Easy Way! C. risk exposures D. cluster interconnect checks Answer: A,C https://kb.netapp.com/app/answers/answer_view/a_id/1003905/~/how-data-ontap-upgrade-advisor-helps-to-perform-adata-ontap-upgrade-or-revert QUESTION NO: 20 You will be purchasing two high availability NetApp AFF A700s systems. You want to set up a 4-node cluster. Which switch would you use for the cluster interconnect switches? A. NetApp CN1610 B. Cisco Nexus 3132Q-V C. CiscoCN1610 Nexus 5548UP NetApp D. Cisco Nexus 5020 Answer: B QUESTION NO: 21 You want to access and mount a Linux LUN using only iSCSl. In the past, the LUN has been accessed using FC. What must you do to accomplish this task? A. Change the LUN protocol type to ISCSI. B. Create a new iSCSI igroup. and change the LUN mapping from the original to the new igroup. C. Create a new iSCSI Igroup and map the LUN to both the new and existing FC igroup. D. Add an iSCSI protocol type to the existing igroup so that the LUN can be accessed by both FC and iSCSI hosts. Answer: A & B ?? QUESTION NO: 22 What are two examples of supported NetApp FC configurations? (Choose two.) A. a single NetApp node directly connected to a single host B. a single switched environment with a NetApp node connected to only one host C. a dual switched environment with a NetApp node connected to multiple hosts D. a single NetApp node directly connected to multiple hosts Answer: B,C QUESTION NO: 23 A4-node ONTAP FAS9000 cluster was used to serve I/O from six RedHat 7.3 servers. The servers were configured with maximum, queue depth. For production purposes, an additional 60 similarly configured hosts were added to the environment. Later, the hosts started reporting random QFull errors, and the aggregated performance degraded. Which two solutions would alleviate the QFull errors and performance problems? (Choose two.) A. Remove Selective LUN Mapping (SIM) from the 4-node FAS9000 cluster. B. Download the latest FC HBA driver, firmware, and BIOS, and deploy them on the hosts. C. Configure and use additional FC target HBAs in the FAS9000 cluster. D. Reduce FC HBA queue depth on the hosts. 11 IT Certification Guaranteed, The Easy Way! Answer: C,D ?? https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanconf%2FGUID-A055B184-0876-43769C75-35FE8C9BE832.html QUESTION NO: 24 A customer is required to encrypt iSCSI traffic across their public network. In this scenario, which method will accomplish this task? A. dot1q B. IPsec C. NVMe D. CHAP Answer: B https://kb.netapp.com/app/answers/answer_view/a_id/1004048/~/what-security-implementations-can-i-use-with-iscsitechnologies%3F- QUESTION NO: 25 Automatic host-side space management with SCSI T10 thin-provisioned LUNs is achieved by which feature of ONTAP? A. fractional reserve B. space allocation C. space reservation D. volume auto-grow Answer: B https://library.netapp.com/ecmdocs/ECMP1196784/html/GUID-6AD84908-041A-497D-95A7-BB6AFDD1B282.html QUESTION NO: 26 Which formula is appropriate for calculating target port Queue Depth? A. The number of LIFs using a physical port * 256 B. The sum of the Queue Depth setting for all hosts using a physical port C. The number of LIFs using the physical port * Maximum Host HBA Queue Depth setting D. The number of physical ports * 2048 Answer: C QUESTION NO: 27 You use iSCSI to present a LUN to a newly installed Windows 2016 Server. You have created the volume and LUN on the NetApp cluster. When you perform a hardware rescan on the Windows host, you cannot see the newly presented storage. What are three reasons for this problem? (Choose three.) A. The protocol has not been enabled on the NetApp cluster. B. You need to add the IQN of the Windows host to the newly created LUN. C. The IQN of the Windows host is not included in the igroup for the new LUN. D. The wrong igroup has been associated with the new LUN. E. The volume has not been enabled for iSCSI access. Answer: I think BCD QUESTION NO: 28 An administrator is migrating from a third-party's SAN to a newly purchased FAS9000. The administrator decides to use the NetApp Foreign LUN Import (FL1) process. What must the administrator do for this process to work properly? 12 IT Certification Guaranteed, The Easy Way! A. Create multiple igroups for the Initiator ports. B. Create six distinct zones that include specific ports within each zone. C. Zone target ports of source storage with initiator ports of destination storage. D. Make the destination LUN larger than the foreign LUN. Answer: C https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanmig-fli%2FGUID-32AB9C37-6151428A-8DC2-B75931BEC1E5.html QUESTION NO: 29 Exhibit: A customer is testing a dual-fabric FC SAN configuration as shown in the exhibit and the zones are implemented on the switches shown below. If all the nodes are in the SLM reporting nodes list, how many path per LUN should the customer expect when simulating an FC SFP failure by bringing LIF_3 offline? A. 15 paths B. 3 paths C. 4 paths D. 7 paths Answer: D QUESTION NO: 30 You have three Windows servers and one Linux server, each with dual-ported HBAs that are connected into a dual fabric. 13 IT Certification Guaranteed, The Easy Way! In this scenario, what is the minimum number of zones that you need to create within each fabric switch? A. 8 B. 1 C. 4 D. 2 Answer: 4 zones per fabric QUESTION NO: 31 You are planning to expand a SAN-only ONTAP 9.5 cluster that consists of eight AFF A700 nodes. In this scenario, what is the maximum number of additional AFF A700 nodes that would be added? A. 2 B. 4 C. 8 D. 0 Answer: B 12 san nodes in a cluster? QUESTION NO: 32 You are testing iSCSI LUN failover across a 4-node FAS9000 fabric-attached MetroCluster configuration. In this scenario, which front end configuration is required for non-disruptive host LUN failover between sites? A. an intercluster LIF B. a stretched Layer 2 network C. Ipv6 D. a stretched VSAN Answer: I think B QUESTION NO: 33 Exhibit: Referring to the exhibit, what is the problem with switch port 0? A. The transmit and receive links were switched. B. The SFP+ is faulty. 14 IT Certification Guaranteed, The Easy Way! C. The receive power is lower. D. The link is not connected. Answer: I think B QUESTION NO: 34 You want to ensure maximum performance of iSCSI LUNs on an AFF A220. In this scenario, which two actions will accomplish this task? (Choose two.) A. Disable flow control. B. Configure virtual LAN (VLAN). C. Enable flow control. D. Enable jumbo frames. Answer: A&D https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.exp-iscsi-esx-cpg%2FGUID-BE5FD8D6-C2E449F3-9040-DF1373A2E325.html QUESTION NO: 35 You need to configure iSCSI on your existing ONTAP cluster in a new SVM. The iSCSI LUNs will be served over a new Layer 2 network using the same physical ports that also use the CIFS protocol on a different SVM. Which two actions should you perform to accomplish this task? (Choose two.) A. Create a new portset. B. Create a new VLAN. C. Create a new broadcast domain. D. Create a new AD object. Answer: B,C QUESTION NO: 36 You want to create an additional SVM from the System Manager GUI to serve data only using block-based protocols. You know the SVM name, the aggregate containing the root volume, and the required protocols. What other information is required to successfully create this SVM? A. name servers B. SVM Management LIF network details C. search domains D. root volume security style Answer: D QUESTION NO: 37 Exhibit: 15 IT Certification Guaranteed, The Easy Way! The VMware ESX host discovers only two of four paths to a LUN on a new ONTAP cluster. Referring to the exhibit, which statement Is correct? A. The fabric zoning configuration does not allow access to the target LlFs. B. The igroup does not contain the WWPN of one initiator. C. The fabric name server is disabled. D. The initiator HBA is not connected to the fabric. Answer: Possibly B but not sure why it says of one initiator. QUESTION NO: 38 Which two are supported in ONTAP 9.5? (Choose two.) A. an NVMe LIF and an FC LIF in the same SVM Not Supported B. an NVMe LIF associated with an FC Direct Connect port not supported C. a NVMe LIF and an FC LIF associated with the same port Yes supported D. multiple NVMe LIFs in the same SVM 2 lifd Supported from 9.5 per SVM Answer: CD https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanag%2FGUID-4B666C44-694A-48A3B0A9-517FA7FD2502.html QUESTION NO: 39 Exhibit: 16 IT Certification Guaranteed, The Easy Way! A customer is testing a dual-fabric FC SAN configuration as shown in the exhibit. The zones are implemented on the switches shown below. IF all the nodes are in the SLM reporting nodes list, how many paths per LUN should the customer expect when simulating a node failure by powering off Node 04? A. 4 paths B. 6 paths C. 8 paths D. 2 paths Answer: B QUESTION NO: 40 You are implementing a new AFF A800 HA pair and are required to migrate NetApp ESeries E2624 data to the AFF A800 controllers. You do not have a host server that is available for the migration. In this scenario, which NetApp migration method is supported? A. OnCommand Unified Manager (OCUM) B. NetApp Data Availability Services (NDAS) C. SnapMirror Synchronous (SM-S) D. Foreign LUN Import (FLI) Answer: D QUESTION NO: 41 Exhibit: 17 IT Certification Guaranteed, The Easy Way! Referring to the exhibit, which type of zoning should be used? A. a WWPN with a single initiator and multiple targets B. a WWPN with a single initiator and a single target C. a WWNN with a single initiator and multiple targets D. a WWNN with a single Initiator and a single target Answer: B QUESTION NO: 42 Exhibit: You have an existing 2-node AFF A300 cluster with premium bundle licensing applied. You need to have consistently low front end latency, and have determined that NVMe satisfies this requirement. Referring to the exhibit, which two actions would accomplish this task? (Choose two.) A. Add a UTA2 adapter to each of the two AFF A300 nodes. B. Add a 32 GB FC HBA to each of the two AFF A300 nodes. C. Apply the license for FCP. D. Apply the license for NVMe. Answer: B,D an NVMe license is required from 9.5 https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cmsanag%2FGUID-5B161BC9-213E-4393-AEC9-8324901EFBF8.html QUESTION NO: 43 You are deploying an 8-node FAS8200 ONTAP cluster and attaching to an existing FC fabric. Which two ONTAP features would be used to restrict or limit the available paths seen from 18 IT Certification Guaranteed, The Easy Way! the host? (Choose two.) A. port sets B. igroup C. VIAN D. Selective LUN Map Answer: A,D https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanag%2FGUID-62ABF745-6017-40B09D65-CE9F7FF66AB3.html QUESTION NO: 44 You currently have a FAS8200 with ONTAP 9.5. You want to expand the front end FC I/O capabilities. However, you are unsure which target adapters are supported. What would you use to confirm which adapters are supported with your current configuration? A. Hardware Universe (HWU) B. Upgrade Advisor C. OneCollect D. Interoperability Matrix Tool (IMT) Answer: A QUESTION NO: 45 You are provisioning a LUN using an ISCSI initiator on an ESX host. You disable Ethernet flow control for all ports but are experiencing Performance issues. In this scenario, which two actions would improve the performance issue? (Choose two.) A. Set the MTU settings 1500 for optimal performance. B. Dedicate your ports to ISCSI traffic. C. Enable jumbo frames across the entire data path. D. Confirm that your host .mil storage polls are connected to a different network. Answer: B,C QUESTION NO: 46 Exhibit: Referring to the exhibit, what is the total amount of space that is guaranteed for the LUNs in the /vo1/vo1_sanlunsiprod_03 volume? A.0GB 19 IT Certification Guaranteed, The Easy Way! B. 300 GB C. 600 GB D. 2600 GB Answer: A ?? QUESTION NO: 47 Exhibit: You have a requirement to serve LUNs with under 200 microsecond latency using local server lass memory. You also are required to use a shared SAN. Using MAX Data as shown in the exhibit, which two LUN access protocols are supported with this solution? (Choose two.) A. iSCSI B. FCoE C. FC D. NVMe Answer: A,C https://library.netapp.com/ecm/ecm_download_file/ECMLP2849021 QUESTION NO: 48 While expanding a 200 GB LUN in an ONTAP 9.4 system, the following error is observed: What is the cause of this error? A. The volume auto-grow is disabled. B. The LUN reached maximum capacity. 20 IT Certification Guaranteed, The Easy Way! C. The LUN can be expanded up to 10 times its original size. D. Space reservation is enabled. Answer: C https://kumaraysun.wordpress.com/2016/09/29/lun-resize-limitation-in-netapp/#more-298 QUESTION NO: 49 Exhibit: You are troubleshooting high CPU use on a FAS8200 with all SAS HDDs. You have SAN hosts with LUNs in a volume named vol1. You want to reduce CPU use and maintain storage efficiencies. Referring to the exhibit which three actions will accomplish this task? (Choose three.) A. Disable compression. B. Enable cross-volume deduplication. C. Disable inline deduplication. D. Enable post process deduplication. E. Enable data compaction. Answer: A,C,D QUESTION NO: 50 Which three components are required for NetApp iSCSI LUN access on Linux servers? (Choose three.) A. device-mapper-multipath B. NetApp SnapDrive C. scsi-target-utils D. iscsi-initiator-utils E. NetApp Host Utilities Answer: A,C,E QUESTION NO: 51 You have an SVM that serves LUNs to your hosts in an FC SAN environment. This SVM runs 21 IT Certification Guaranteed, The Easy Way! on a 4-node cluster and has two data LIFs on each node, according to best practices. You just created a LUN and mapped it to your initiators group. The LUN is owned by node01. In this scenario, what would be an appropriate test for LUN mobility? A. Move the LUN to node02. B. Mirror the LUN to another node in your cluster. C. Physically disconnect the SAN ports, and verify if the SAN data LIFs automatically move to other hosts. D. Copy the LUN to another node and create a new LUN map. Answer: A QUESTION NO: 52 Exhibit: 22 IT Certification Guaranteed, The Easy Way! You are working on a project to install a new AFF A300 storage array. You use a pair of Nexus 3596 switches for FC connectivity between your VMware ESXi servers and the AFF A300. Which SAN switch feature must be enabled to accomplish this task? A. N_Port ID visualization (NPIV) B. Open Shortest Path First (OSPF) C. Link Aggregation Control Protocol (LACP) D. N_Port Visualization (NPV) Answer: A QUESTION NO: 53 You are provisioning storage to an ESX host that uses iSCSI. According to NetApp best practice, which three actions accomplish this task? (Choose three.) A. Enable the iSCSI service. B. Bind the iSCSI ports to the software iSCSI adapter. C. Install Virtual Storage Console (VSC) for VMware. D. Enable BGP on the switch. E. Configure MTU 1500 on the switch. Answer: ABC QUESTION NO: 54 Exhibit: You have a performance critical database application that is running on a FAS9000 controller that uses FC. As shown in the exhibit, volume efficiency is enabled. If you follow the performance recommendation, what are two results to the data in the volume? (Choose two.) A. The new written data is compressed. B. The new written data is uncompressed. C. The existing data is uncompressed. D. The existing data is compressed. 23 IT Certification Guaranteed, The Easy Way! Answer: A,C QUESTION NO: 55 A customer wants to use both Cisco FC and FCoE switches in their ONTAP environment. According to NetApp best practices, what are two requirements in this scenario? (Choose two.) A. You must use single initiator zoning. B. You must create interface groups to isolate FC and FCoE LIFs. C. You must create a trunk with multiple virtual LANs. D. You must not have more than one target LIF for the same physical port in a single fabric zone. Answer: A,D QUESTION NO: 56 A company has 20 ESX hosts. Ten of the hosts are connected using FC, and the rest are connected over iSCSI. The FC host HBA queue depth is set to 32, and the iSCSI LUN queue depth is set to 64. The FC hosts are now experiencing random connectivity issues. In this scenario, what would be the reason for the disconnects? A. The FC host has a lower queue depth. B. According to the IMT, unsupported HBA firmware is in use. C. All of the hosts are part of the same cluster. D. The queue depth is not consistent across the cluster. Answer: A QUESTION NO: 57 You have a 4 node cluster with an AFF A300 HA pair and a FAS8200 HA pair. You plan on using the default storage efficiency settings. With inline data compaction, you estimate that you can save 6% of storage space. AFF A300 LUNs that use under 5000 IOPS are moved to a FAS8200 using the lun move command. In this scenario, what happens to the data after the LUN is moved? (Choose two.) A. The new written data is not compacted. B. The new written data is compacted. C. The existing data is compacted. D. The existing data is not compacted. Answer: A,D https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanag%2FGUID-84BF574F-694B-4D2A9E5D-4EBE33FDC23A.html QUESTION NO: 58 Which NetApp tool views automated, schedule configuration, and performance data for a customer's SAN from a Web browser? A. Virtual Storage Console B. OnCommand Workflow Analyzer C. Config Advisor D. Active IQ Answer: D 24 IT Certification Guaranteed, The Easy Way! QUESTION NO: 59 Which two scenarios in deploying ONTAP Cloud are supported by the Cloud Manager tool? (Choose two.) A. ONTAP Cloud deployed as an HA pair on IBM Cloud B. ONTAP Cloud deployed as an HA pair on VMware C. ONTAP Cloud deployed as a single instance on Microsoft Azure D. ONTAP Cloud deployed as an HA pair on Amazon Web Services Answer: C,D QUESTION NO: 60 Exhibit: A customer has an AFF A700 connected to a Cisco switch and has verified connectivity but cannot see any LUNs. The customer issued the run -node scaling-01 -command fcp topology show command to verify the connection. Referring to the exhibit, what needs to be enabled on the Cisco switch? A. Trunking needs to be enabled. B. VSAN needs to be enabled. C. NPIV needs to be enabled. D. VFC needs to be enabled. Answer: I think C QUESTION NO: 61 An administrator has a 2node AFF ONTAP cluster named cl1. A Windows 2016 server has 10 FC LUNs mapped from the cluster , and the administrator can multiple paths to each LUN, During a scheduled storage failover, node cl1-02 took over cl1-01, and Windows server lost connectivity to all mapped LUNs but reestablished connectivity after the giveback operation finished. In the scenario, what would cause the LUN connectivity outage? A. Multipathing software is not installed on the host. 25 IT Certification Guaranteed, The Easy Way! B. Switch zoning does not exist between the host initiator ports and the data LIFs that reside no node cl-01. C. NPIV is not enabled on the switches. D. Switch zoning does not exist between the host initiator ports and the data LIFs that reside on node cl1-02. Answer: D QUESTION NO: 62 You have a 4-node cluster with a FAS8200 HA pair and an AFF A300 HA pair. You need to migrate a LUN from a FAS8200 node to an AFF A300 node for faster performance. Which method will non-disruptively migrate the LUN to the AFF A300 while retaining snapshots of the LUN on the FAS8200? A. You move the LUN. B. You relocate the aggregate. C. You move the volume. D. You copy the LUN. Answer: c QUESTION NO: 63 As a system administrator, you perform a routine check of available storage space on your FAS2750. You notice that the vol_1 volume is approaching 100% capacity. The volume is configured with the space guarantee set to volume and the LUN reservation is disabled. You want to free up space in the volume without increasing its size. Which action would accomplish this task? A. Increase the size of the LUN. B. Increase the Snapshot Reserve. C. Increase the aggregate size. D. Use deduplication. Answer: D QUESTION NO: 64 When planning out a new FC SAN implementation for a AFF cluster, which two variables should be considered for a highly-available, resilient solution? (Choose two.) A. Length of LC/LC optic cables B. Multiple disk shelves C. Multiple PDUs connected to separate circuits D. Data-fabric zones using multiple switches Answer: C,D QUESTION NO: 65 What does the space allocation argument in a lun create command do? A. It thick provisions the LUN. B. It only disables space reclamation (or the LUN. C. It thin provisions the LUN, 26 IT Certification Guaranteed, The Easy Way! D. It enables or disables space reclamation for the LUN Answer: D QUESTION NO: 66 Exhibit: A customer has an AFF A200 with a LUN residing in a volume by Node 4. The default Selection Mapping settings are effect. During a planned takeover cluster test, Node 3 performs a take over of Node 4. Referring to the exhibit, what is the expected number of paths seen from the host? A. 6 B. 8 C. 4 D. 2 Answer: A QUESTION NO: 67 Exhibit: 27 IT Certification Guaranteed, The Easy Way! You are asked to change the iSCSl Target Node Name of an SVM named SVM1 that is serving data. Referring to the exhibit, which two statements are correct? (Choose two.) A. Reconnect all the LUNs alter renaming the target node. B. Disable Selective LUN Mapping (SLM) and create port sets. C. Unmap and re-map the LUNs. D. Stop and start the iSCSI service. Answer: C,D QUESTION NO: 68 On your ONTAP 9.5 cluster, you need to set up the onboard key manager with hardware-based security and volume encryption. Which two licenses are required in this situation? (Choose two.) A. FDE Full Disk Encryption B. TPM Trusted Platform Module https://www.dburkland.com/trusted-platform-module-tpmsupported-platforms/ C. D. VE ?? Don’t think this is a real NetApp License ?? E. RSA Don’t think this is a real NetApp License ?? Answer: A&B QUESTION NO: 69 You recently bought a FAS8200 series with SAS drives and want to maximize data efficiencies. Performance is not a primary. Which two statements are correct in this scenario? (Choose two.) A. Enable both inline and post process efficiencies. B. Enable always-on compaction. C. Enable always-on deduplication. D. Enable compression. Compression only AFF Answer: AC https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-vsmg%2FGUID-9C88C1A6-990A-482683F8-0C8EAD6C3613.html QUESTION NO: 70 You are planning few a new AFF A700 2-node switchless FC solution with two Cisco 9100 switches. Each AFF A700 will have one 16 Gb port Connected to each Cisco 9100 switch and four FC LIFs per physical port. You want to guarantee recovery from connection loss on a NetApp physical port and you are using single initiator to multiple target zoning. What is the minimum number of zones required to accomplish this task? 28 IT Certification Guaranteed, The Easy Way! A. 8 B. 4 C. 2 D. 1 Answer: C QUESTION NO: 71 Which data collection tool would be used for obtaining detailed information about hosts that are attached to ONTAP storage? A. Upgrade Advisor B. OneCollect C. Brocade Network Advisor D. Conflg Advisor Answer: B QUESTION NO: 72 Exhibit: An administrator has an AFF A200 HA pair. Referring to the exhibit, how many 10 Gbps connections would the customer have on a single node for SAN host connectivity? A. 4 B. 6 C. 7 D. 2 Answer: A QUESTION NO: 73 A customer's Red Hat Linux 7.0 server's Linux native DM-MP settings for multi pathing have not been set correctly. In this scenario, what would cause this problem? A. The multi path, conf file contains the blacklist stanza. 29 IT Certification Guaranteed, The Easy Way! B. Challenge-Handshake Authentication Protocol (CHAP) is not enabled. C. The rdloaddriver=scsi_dh_alua was not added to the end of the boot loader file. D. The incorrect WWID was added to the multipath.conf file. Answer: D QUESTION NO: 74 Which path selection policy is used by Windows Servers using NetApp LUNs that are greater than 2 TB? A. Least Queue Depth B. Round Robin C. Round Robin with Subset Policy D. Least Weighted Paths Answer: C https://library.netapp.com/ecmdocs/ECMP1307349/html/GUID-29CBF302-D78C-4A38-900D-9F1E8DDB0D6A.html QUESTION NO: 75 Exhibit: Which two storage efficiencies have been enabled on the NVMe namespace that is shown in the exhibit? (Choose two.) A. deduplication B. compaction C. compression D. thin provisioning Answer: A&C QUESTION NO: 76 You have a 4-node cluster with an AFF A300 HA pair and a FAS8200 HA pair. You plan on using the default storage efficiency settings. With inline data compaction, you estimate that you can save 6% of storage space. AFF A300 volumes that use under 5000 IOPS are moved to a FAS8200 using the volume move command. In this scenario, what happens to the data after the volume is moved? (Choose two.) A. The new written data is not compacted. B. The existing data is compacted. C. The new written data is compacted. 30 IT Certification Guaranteed, The Easy Way! D. The existing data is not compacted. Answer: A&D ??? QUESTION NO: 77 You must relocate a LUN from one AFF A700 HA pair to another AFF A300 HA pair while preserving all storage efficiencies. What are two ways to accomplish this task? (Choose two.) A. Copy the volume. B. Copy the LUN. C. Move the volume. D. Move the LUN. Answer: A,C QUESTION NO: 78 You have inherited a small FC SAN infrastructure that consists of 15 servers (hosts), two Cisco MDS 9148s switches, and a 4-node NetApp AFF A300 cluster. You suspect that your predecessor did not configure zoning according to best practices. In this scenario, what information is necessary to audit your SAN zoning? (Choose two.) A. SVM WWNNs B. SVM LIF WWPNs C. Controller port WWPNs D. Host HBA WWPNs Answer: B,D QUESTION NO: 79 You are planning to implement a 32 Gb FC SAN on a 2-node AFF A700 ONTAP 9.5 cluster. You need to create 112 FC LIFs across the HA pair with a limit of 20 FC LIFs per physical HBA port. In this scenario, how many 2-port 32 Gb HBA cards do you need per storage controller? A. 2 B. 1 C. 4 D. 3 Answer: A QUESTION NO: 80 Exhibit: 31 IT Certification Guaranteed, The Easy Way! A customer wants to add a 2-port, 32 Gb FC card to support NVMe in an AFF A700 2-node cluster. Currently, there are cards in slots 1, 2, 4, 6, 8, and 9. Referring to the exhibit, what is the number of the slot that should be used? A. 10 B. 3 C. 5 D. 7 Answer: A QUESTION NO: 81 You want to provision an iSCSl LUN. Which two steps are required to accomplish this task? (Choose two.) A. Add the initiator IP address to the igroup. B. Map the LUN to the igroup. C. Add the target WWPN to the igroup. D. Add the initiator IQN to the igroup. Answer: B,D QUESTION NO: 82 Exhibit: You are asked to serve iSCSI LUNs in an existing SVM on your AFF A220 using ONTAP 9.5. You verified that the iSCSI license is configured on your cluster and that the iSCSI protocol is enabled. Referring to the exhibit, what is needed to allow hosts to log into the iSCSI target? 32 IT Certification Guaranteed, The Easy Way! A. Create new LIFs with the iSCSI data protocol. B. Create new igroups with the host IQNs. C. Add iSCSI to the data protocol of the existing LIFs. D. Map LUNs to the igroups. Answer: I think A https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-nmg%2FGUID-CEE760DF-A059-4018BE6C-6B3A034CB377.html QUESTION NO: 83 Exhibit: Referring to the exhibit, which two LIFs would be optimized paths to LUN /vol/OraDev_Vol/OraDev? (Choose two.) A. aff_node-01_0g_A B. aff_node-02_0e_A C. aff_node-02_0g_A D. aff_node-01_0e_A Answer: A&D https://kb.netapp.com/app/answers/answer_view/a_id/1003251/~/asymmetric-logical-unit-access-%28alua%29-support-onnetapp-storage---frequently QUESTION NO: 84 Exhibit: 33 IT Certification Guaranteed, The Easy Way! You want to configure a UTA2 port as an FCoE target. Referring to the exhibit, which action must be performed? A. Configure the port mode as CNA. B. Configure the port mode as Ethernet. C. Configure the port type as initiator. D. Configure the port mode as FC. Answer: A QUESTION NO: 85 Which two components must be verified for a supported NetApp SAN confutation? (Choose two.) A. host memory B. host CPU C. host multipath D. host bus adapter Answer: C,D QUESTION NO: 86 You are configuring both NVMe and FC on the same AFF A800 2-node ONTAP 9.5 cluster. You are configuring both protocols on the same Cisco FC network switches. In this scenario, which configuration on the cluster is supported? A. a volume with both LUNs and namespaces B. an SVM with both nvme and fcp allowed protocols C. an AFF A800 node HBA with both NVMe/FC and FC on the same port D. a LIF with both fc-nvme and fcp data protocols Answer: I think C https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanconf%2FGUID-A39311D7-D917-4462862C-4AC844EB4CA9.html QUESTION NO: 87 Exhibit: 34 IT Certification Guaranteed, The Easy Way! An administrator has an ONTAP cluster with SVMs and LUNs as shown in the exhibit. Hosts attempting to connect to LUNs mapped from SVM "C" are unable to see their LUNs. The hosts are not configured to connect to any other SVM. Which action should be performed to restore multi-path connectivity to the LUNs in this scenario? A. Create LIFs on SVM "C" for host connectivity. B. Move the LUN to a different volume within SVM "C". C. Move the LUN to SVM "E" to restore connectivity. D. Move the LUN to SVM "A" to restore connectivity. Answer: A QUESTION NO: 88 Exhibit: 35 IT Certification Guaranteed, The Easy Way! The host in the exhibit is connected to a 4-node ONTAP SAN using dual-fabric implementation. LUNs have been mapped through all available LIFs. Switch 2 is powered off for high-availability testing. How many paths per LUN would you expect the host to see in this scenario? A. 2 B. 6 C. 4 D. 8 Answer: C QUESTION NO: 89 Exhibit: 36 IT Certification Guaranteed, The Easy Way! You want to map a LUN to a server. To which SAN object is the highlighted value in the exhibit added? A. LUN B. fabric zone C. FlexClone D. igroup Answer: D QUESTION NO: 90 A customer wants to move its iSCSI SAN data from the edge locations into the cloud for data analytics, while keeping the ability to access modify the data. Which two combined solutions meet the customer's requirements in this scenario? (Choose two.) A. Use Microsoft Azure compute resources to access the near cloud AFF SnapMirror data for 37 IT Certification Guaranteed, The Easy Way! analytics. B. Deploy ONTAP Cloud at edge locations find use SnapVault to move the data into an AFF on-premises data center. C. Deploy ONTAP Select at edge locations and use SnapMirror to move the data to AFF near cloud with the NetApp Private Storage (NPS) service. D. Use Amazon Web Services (AWS) compute resources to access ONTAP Select data at the edge office locations for analytics. Answer: A,D QUESTION NO: 91 A customer that is using an AFF A220 has a problem with a host for a new FC LUN. Other LUNs on the same SVM are working properly. This LUN is not visible on the host. Which configuration does the customer need to verify in their solution? A. LUN mapping with igroup B. host HBA speed settings C. FC target port setting on NetApp node D. FC switch zoning Answer: A QUESTION NO: 92 You have a 4-node FAS8200 AFF A300 cluster that are using ONTAP 9.3 default settings. For faster performance, you move a volume with LUNs from a node on the FAS8200 to a node on the AFF A300. You determine that your SAN host is still using all active/optimized FC paths to the FAS8300 HA pair. What do you need to troubleshoot to move all active/optimized FC paths to the AFF A300 HA pair? A. reporting nodes list B. host MPIO and ALUA C. LUN mapping D. igroup WWPNs Answer: A QUESTION NO: 93 Exhibit: 38 IT Certification Guaranteed, The Easy Way! Referring to the exhibit, what is the total number of target LUNs that are being accessed? A. 4 B. 1 C. 2 D. 8 Answer: B QUESTION NO: 94 A customer experiences intermittent connectivity problems between an ESXi server and FC LUNs in an SVM. The customer has examined the nodes hosting the LUNs and both the disk and CPU performance are below 50% utilization. The customer examined the switch ports connected to the storage array, and they are also below 50% utilization. Which two steps would you perform next in this scenario? (Choose two.) A. Verify that the host is using SnapDrive. B. Verify that the host Ethernet interfaces are using jumbo frames. C. Verify that the host recommended settings were applied by Virtual Storage Console. D. Verify that the HBA queue depth is set properly. Answer: C,D QUESTION NO: 95 Exhibit: 39 IT Certification Guaranteed, The Easy Way! You are moving volumes between aggregate aft_01_aggr1 and the aggregate Aggr_Data shown in the exhibit. How much space will be moved? A. 11.17 TB B. 935.75 GB C. 296 KB 40 IT Certification Guaranteed, The Easy Way! D. 1. 91 TB Answer: C QUESTION NO: 96 Exhibit: Referring to the exhibit, which two elements are required for NVMe host access with ONTAP 9.5 and using supported AFF nodes? (Choose two.) A. You need 16 Gb FC HBAs installed in the AFF nodes. B. You must have the license installed for NVMe support in the cluster. C. You must have the license installed for FC support in the cluster. D. You need 32 Gb FC HBAs installed in the AFF nodes. Answer: B&D 41 IT Certification Guaranteed, The Easy Way! QUESTION NO: 97 Exhibit: You need to configure the SnapCenter Plug-in for VMware vSphere to back up and restore VMware datastores. Referring to the exhibit, which additional LIF type should you create before you configure the plug-in? A. intercluster B. node management C. SVM management D. cluster management Answer: C QUESTION NO: 98 Exhibit: 42 IT Certification Guaranteed, The Easy Way! You configured a SAN host with a 4-node ONTAP 9.5 cluster that uses default settings. All paths are available from the host to the four nodes. You have a requirement to see only two paths to each LUN. One path is optimized and the other is non-optimized. In this scenario, which NetApp SAN feature supports this requirement? A. portsets B. SLM C. VLANs D. igroups Answer: I think B QUESTION NO: 99 An administrator needs to connect a new VMware 6.5 cluster to an ONTAP cluster for iSCSl connectivity. Which two steps would accomplish this task? (Choose two.) A. Enable iSCSl adapters on the ESXi hosts. B. Install the Virtual Storage Console for VMware vSphere. C. Configure zoning for the HBAs and the ONTAP data LIFs. Zoning is FC D. Configure ALUA on the ONTAP SVM. No config necessary Answer: A&B 43 IT Certification Guaranteed, The Easy Way! QUESTION NO: 100 Which two features does Assymmetric Namespase Access (ANA) support? (Choose two.) A. multipathing B. LUN masking C. LUN hosting D. path management Answer: A,D QUESTION NO: 101 Exhibit: A customer is using both FC and NVMe in a cluster. The customer needs to do some work on AFF_1. Referring to the exhibit, what will happen? A. The NVMe namespaces on AFF_2 will be available after takeover of AFF_1. B. The FC LUNs that use cluster interconnect to access the LUNs on AFF_1 will be unavailable after failover. C. The FC LUNs on node AFF_2 will be unavailable after failover of AFF_1. D. The NVMe namespaces on AFF_1 will be unavailable after takeover by AFF_2. Answer: I think D theres no nvme lif on node 2 QUESTION NO: 102 An administrator is configuring their Ethernet switches to support an AFF A300 cluster that will be providing iSCSI LUNs to servers. The switches are also used for other traffic from various hosts. In this scenario, which statement about the switch configuration is correct? A. Use a larger MTU size at the SAN connection rather than the host connections to allow for greater SAN bandwidth. B. Use network ports as access ports only. C. Use multiple VLANs to segregate iSCSI traffic from other traffic types D. Use a single VLAN to consolidate all data traffic on the switches. Answer: I think C 44 IT Certification Guaranteed, The Easy Way! QUESTION NO: 103 You have a thin-provisioned LUN that was created by using the lun create -vserver vs1 path /vol/vol1/lun1 -size 500G -ostype windows 2008 -space-reserve disabled -spaceallocation disabled command. You verify that your Windows 2016 host reports 200 GB free on lun1. However, lun1 shows 0 bytes free on the storage cluster. What should you do to solve this problem? A. Change the LUN -space-allocation parameter to enabled. B. Change the LUN -ostype parameter to windows_gpt. C. Change the LUN -space-reserve parameter to enabled. D. Rescan the LUN disk in your Windows host so that it will notify NetApp about the free space. Answer: I think A QUESTION NO: 104 An administrator has an AFF A200 cluster at their primary site that is used for FC connectivity to servers. For disaster recovery purposes they want to start replicating their data to another AFF A300 cluster In a secondary location. The AFF A300 is In a site that has no FC or FCoE capable switches, and is currently only used for CIFS data. A cluster peering relationship already exists between the two clusters. Which three additional actions are needed for the data to be ready for access from hosts at the secondary site? (Choose three.) A. Create zones with the appropriate initiators and targets for the secondary site. B. Enable the iSCSI service on the SVM at the secondary site. C. Replicate the data from the primary site to the secondary site with SnapMirror. D. Create new iSCSI igroups for LUN mapping. E. Enable the iSCSI service on the SVM at the primary site. Answer: B,C,D QUESTION NO: 105 Your server administrator upgraded a Windows 2016 Server from 16 Gb to 32 Gb HBAs. The application owner is now reporting slower performance to the AFF A700. Which two actions will help troubleshoot performance on the server? (Choose two.) A. Verify the HBA model using Hardware Universe. B. Verify the HBA firmware using the Interoperability Matrix Tool. C. Confirm that LUN mapping exists. D. Confirm that Windows Host Utilities Is installed. Answer: A,B QUESTION NO: 106 You want to connect a NetApp AFF A700 to a 32 Gb FC switch. The ports need to connect at 32 Gb speed. In this scenario, which statement is correct? A. The AFF A700 includes FC ports natively on the controller. B. The AFF A700 includes an additional FC I/O module that is already populated in each 45 IT Certification Guaranteed, The Easy Way! controller. C. You need to purchase a two-port or four-port unified I/O module that enables FC and Ethernet connectivity. D. You need to purchase a two-port or four-port FC I/O module. Answer: I think D QUESTION NO: 107 Exhibit: Referring to the exhibit, which container gains space savings from deduplication, compression and compaction? A. the aggregate B. the qtree C. the volume D. the LUN Answer: C QUESTION NO: 108 An administrator is configuring a SAN-only cluster. The data room that houses four AFF A220 controllers is small and not able to house the DS224C shelves. The administrator proposes to rack the shelves in a separate room that is 40 meters away from the controllers. In this situation, how would you properly cable the controllers to the shelves? A. Use multimode passive optical cables. B. Use multimode active copper cables. C. Use multimode active optical cables. D. Use multimode passive copper cables. Answer: C QUESTION NO: 109 Exhibit: 46 IT Certification Guaranteed, The Easy Way! Referring to the exhibit. What are two viable scenarios to test LUN multipathing on Host 1? (Choose two.) A. Reboot one of the switches. B. Disable one of the FC LIFs on Controller 1. C. Disconnect one of the host cables. D. Reboot Host 1. Answer: I think A&B QUESTION NO: 110 You have an SVM that serves LUNs to your hosts in an FC SAN environment. This SVM runs on a 4-node cluster and has two data LIFs on each node, according to best practices. You just created a LUN and mapped it to your initiators group. The LUN is owned by node01. In this scenario, what would be an appropriate test for LUN mobility? A. Copy the LUN to another node and create a new LUN map. B. Physically disconnect the SAN ports, and verify if the SAN data LIFs automatically move to other hosts. C. Move the LUN to node02. D. Mirror the LUN to another node in your cluster. Answer: C QUESTION NO: 111 You deployed a new SVM for FC access, and you used the vserver create -vserver svm1 - status-admin up command to enable FC service on the SVM. You then created the LIFs for the FC protocol. When you review the status of the LIFs, they show that the admin status is up, but the operational status is down. You have already verified that the ports are physically connected. In this scenario, what is the next step to bring the LIFs up? A. Use the network interface modify command to change the operational status of the LIFs. 47 IT Certification Guaranteed, The Easy Way! B. Create at least one zone that contains your SVM LIF WWPNs and an initiator. C. Verify that an FC license is applied on your system. D. Disable the SAN switch port where your NetApp storage is connected. Answer: B QUESTION NO: 112 An administrator who is using the Virtual Storage Console (VSC) creates a new FC datastore on an existing volume. While the datastore was provisioned, two hosts were in maintenance mode. When the maintenance was completed, the two hosts do not have access to the new datastore, but they have access to other datastores on the same volume. In this scenario, what caused this result? A. The VSC cannot create datastores while hosts are in maintenance mode. B. During host maintenance, the FC HBAs were replaced with different FC HBAs. C. The VSC created a new igroup that contains only the hosts that were online during the datastore creation. D. After creation using the VSC, the administrator needs to create a LUN mapping. Answer: C QUESTION NO: 113 An enterprise customer has both a NetApp FAS8200 4-node cluster and a third-party storage array in a shared SAN environment. The host servers connect to both storage vendors' arrays in the fabric. Regarding the hosts in this scenario, what are two NetApp best practices when performing this task? (Choose two.) A. Set the default timeout values and storage parameters for the host system. B. Provide isolation between storage systems using NetApp's multitenancy feature. C. Always use the same adapter for heterogeneous storage systems. D. Use separate adapters to connect to each vendors' storage system. Answer: A,D QUESTION NO: 114 A customer is planning to connect a Linux server to a FAS8200 using Brocade FC switches. During the initial configuration, the SVM does not log in to the fabric. Which two statements are correct in this scenario? (Choose two.) A. NPIV has not been enabled on the switches. B. The switch port topology is set incorrectly to the E_Port. C. ALUA has not been set up on the FAS8200. D. Zoning is incorrectly configured between the Linux server and the ONTAP cluster. Answer: I think A&D QUESTION NO: 115 An administrator has expanded a 2-node ONTAP cluster to a 4-node ONTAP cluster. The cluster is using FC LUNs with all of the default settings. You must rebalance the LUNs to the new nodes. 48 IT Certification Guaranteed, The Easy Way! Which configuration must be made to achieve this requirement? A. The new nodes must be added to the reporting nodes list. B. All nodes must be removed from the reporting nodes list. C. The original nodes must be added to the reporting nodes list. D. The original nodes must be removed from the reporting nodes list. Answer: A QUESTION NO: 116 An administrator has a new AFF A220 system with two DS224C disk shelves and wants to validate if the shelf cabling is correct. Which resource would be used to accomplish this task? A. Config Advisor B. OnCommand Unified Manager (OCUM) C. OneCollect D. Interoperability Matrix Tool (IMT) Answer: A QUESTION NO: 117 Exhibit: A customer needs to change ports 0e and 0f on AFF_1 to support FC. Referring to the exhibit, which three steps are required to accomplish this task? (Choose three.) A. Issue the ucadmin modify -node AFF_1 -adapter 0e -mode FC -type target command. B. Issue the ucadmin modify -node AFF_1 -adapter 0e -mode FC -type initiator command. C. Restart the FC service. D. Take ports 0e and 0f offline. E. Reboot the node. Answer: A,D,E QUESTION NO: 118 Exhibit: 49 IT Certification Guaranteed, The Easy Way! You connected your FAS8200 to a Brocade SAN switch. As shown in the exhibit, port 0e is not available. In this scenario, which statement is correct? A. The incorrect SFP+ module is installed. B. The switch zoning is using the FC nodename. C. The incorrect firmware revision is installed. D. The switch port is configured for mode E_Port. Answer: I think A ?? QUESTION NO: 119 Which tool collects configuration data from hosts and switches to assist in evaluating a qualified configuration? A. System Manager B. sysstat. command C. SnapCenter D. OneCollect Answer: D QUESTION NO: 120 Exhibit: 50 IT Certification Guaranteed, The Easy Way! During a data mobility test on a 4-node ONTAP 9.3 cluster, the host loses direct access to its LUNs. The LUNs are hosting on node cl1-01 and are being moved to cl1-03 on a different HA pair. Referring to the exhibit, which corrective step is needed to ensure access while the volume is moved? A. Add reporting nodes for cl1-03 and cl1-04. B. Create additional LIFs on cl1-01 and cl1-02. C. Create a new destination volume on cll-03. D. Create new igroups on cl1-03 and cl1-04. Answer: A 51