From: "Heller, Michael" <michael.heller@miraclon.com> Date: Tuesday, August 4, 2020 at 3:20 PM To: Miguel Tristani-Kendra <miguel.tristani-kendra@miraclon.com> Subject: Update Hi Miguel, I started the bubble test on R20-011 (DS001) control and Exp. Conditions. The test will conclude on Thursday. The plates are 39 days old at start of test. Also looked up some peel forces of delaminating TIL and TIL-R peel from plate after UV exposure. The TIL peel is from testing of cycle 39 from 3/30/2011. TIL-R peel is from July this year. TIL No image 100% DC 0.35 N/cm 0.64 N/cm TIL-R No Image 100% DC 0.25 N/cm 0.47 N/cm Peel Force TIL-R fr plate Peel Force TIL-R fr plate 250 700 600 200 500 Force, g Force, g 150 NXH114 no ablation 1 100 DS001 no ablation 1 400 NXH114 100% DC 1 300 DS001 100% DC 1 200 50 100 0 0 0 1 2 3 Time, s 4 5 6 0 1 2 3 Time, s 4 5 6