Uploaded by Juan Pablo Montiel

KKSsiemens

advertisement
nd
2 complete, non-project related edition
th
Basis VGB 4 Edition
Revision b, Condition-Date: January 20, 1999
Identification System for Power Plants
Function key
Equipment unit key
Component key
Proj.-Code.
UA
Contents Code
ZEN000
DA01 383
Consec. No.
UNID
Index
970404
1 000 822 159
b
KKS
Identification System for Power Plants
Change notification No. 2
Revision „b“ of 20.01.99
Please print out the pages and update your KKS Manual according to the following table.
For print-out on both sides the pages HA1 of HA1, HN1 of HN1 and HS1 of HS2 have been added.
Page
Index
H1 of H1
HR1 of HR2
HR2 of HR2
b
a
a
KWU OI42
Hünecke
Tel. +49 (0)69/807-2078
Revision
date
20.01.99
20.01.99
20.01.99
Exchange
Addition
Deletion
Remarks
X
X
X
31.07.98
KKS
Identification System for Power Plants
Change notification No. 1
Revision „a“ of 31.07.98
To update your KKS Manual you find the revised pages in the Intranet:
KWU-Homepage/Handbücher, Regelwerke/KKS Documentation.
Please print out the pages and update your KKS Manual according to the following table.
Page
Index
HA1 of HA1
MB1 of MB2
MF1 of MF1
MG1 of MG1
MK1 of MK1
X1 of X1
XG1 of XG1
XK1 of XK1
a
a
a
a
a
a
a
a
KWU OI42
Hünecke
Tel. +49 (0)69/807-2078
Revision
date
31.07.98
31.07.98
31.07.98
31.07.98
31.07.98
31.07.98
31.07.98
31.07.98
Exchange
Addition
Deletion
Remarks
X
X
X
X
X
X
X
X
31.07.98
Siemens
2 nd complete, non-project related edition
Identification System for Power
Plants
General view Function key
Condition-Date: 04.04.97
A
Grid and distribution systems
B
Power transmission and auxiliary power supply
C
Instrumentation and control equipment
D
Instrumentation and control equipment
E
Conventional fuel supply and residues disposal
F
Handling of nuclear equipment
G
Water supply and disposal
H
Conventional heat generation
J
Nuclear heat generation
K
Reactor auxiliary systems
L
Steam, water, gas cycles
M
Main machine sets
N
Process energy supply for external users (e. g. district heating)
P
Cooling water systems
Q
Auxiliary systems
R
Gas generation and treatment
S
Ancillary systems
U
Structures
W
Renewable energy plants
X
Heavy machinery (not main machine sets)
Z
Workshop and office equipment
Printout date: 12. Sep. 01
Page 1 of 1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : A
04.04.97
A
Grid and distribution systems
AB
> 420 kV systems
AC
380 - (420) kV systems
AD
220 - (245) kV systems
AE
110 - (150) kV systems
AF
60 - (72) kV systems
AG
45 - (50) kV systems
AH
30 - (35) kV systems
AJ
20 - (25) kV systems
AK
10 - (15) kV systems
AL
6 - (5) kV systems
AM
1 - 3 kV systems
AN
< 1 kV systems
AP
Control consoles
AQ
Measuring and metering equipment
AR
Protection equipment
AS
Decentralized panels and cabinets
AT
Transformer equipment
AU
Open-loop control, checkback and auxiliary equipment
AV
Marshalling racks
AW
Instrument panels
AX
Central equipment
AY
Communication equipment
Printout date 14. Mrz. 01
Page A1 of A1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : AB
04.04.97
A
Grid and distribution systems
AB
> 420 kV systems
Printout date 14. Mrz. 01
Page AB1 of AB1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : AC
04.04.97
A
Grid and distribution systems
AC
380 - (420) kV systems
Printout date 14. Mrz. 01
Page AC1 of AC1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : AD
04.04.97
A
Grid and distribution systems
AD
220 - (245) kV systems
Printout date 14. Mrz. 01
Page AD1 of AD1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : AE
04.04.97
A
Grid and distribution systems
AE
110 - (150) kV systems
Printout date 14. Mrz. 01
Page AE1 of AE1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : AF
04.04.97
A
Grid and distribution systems
AF
60 - (72) kV systems
Printout date 14. Mrz. 01
Page AF1 of AF1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : AG
04.04.97
A
Grid and distribution systems
AG
45 - (50) kV systems
Printout date 14. Mrz. 01
Page AG1 of AG1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : AH
04.04.97
A
Grid and distribution systems
AH
30 - (35) kV systems
Printout date 14. Mrz. 01
Page AH1 of AH1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : AJ
04.04.97
A
Grid and distribution systems
AJ
20 - (25) kV systems
Printout date 14. Mrz. 01
Page AJ1 of AJ1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : AK
04.04.97
A
Grid and distribution systems
AK
10 - (15) kV systems
Printout date 14. Mrz. 01
Page AK1 of AK1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : AL
04.04.97
A
Grid and distribution systems
AL
6 - (5) kV systems
Printout date 14. Mrz. 01
Page AL1 of AL1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : AM
04.04.97
A
Grid and distribution systems
AM
1 - 3 kV systems
Printout date 14. Mrz. 01
Page AM1 of AM1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : AN
04.04.97
A
Grid and distribution systems
AN
< 1 kV systems
ANA
Low voltage switchgear 500-1000 V, AC
ANB
Low voltage switchgear 500-1000 V, AC
ANC
Low voltage switchgear 500-1000 V, AC
ANE
Low voltage switchgear 380/220 V, AC
ANF
Low voltage switchgear 380/220 V, AC
ANG
Low voltage switchgear 380/220 V, AC
ANH
Low voltage switchgear 380/220 V, AC
ANK
DC switchgear 220/110 V
ANL
DC switchgear 220/110 V
ANM
DC switchgear 220/110 V
ANN
DC switchgear 220/110 V
ANQ
DC switchgear 60/48 V
ANR
DC switchgear 60/48 V
ANS
DC switchgear 60/48 V
ANU
DC switchgear 24/12 V
ANV
DC switchgear 24/12 V
ANW
DC switchgear 24/12 V
Printout date 14. Mrz. 01
Page AN1 of AN1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : AP
04.04.97
A
Grid and distribution systems
AP
Control consoles
Printout date 14. Mrz. 01
Page AP1 of AP1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : AQ
04.04.97
A
Grid and distribution systems
AQ
Measuring and metering equipment
Printout date 14. Mrz. 01
Page AQ1 of AQ1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : AR
04.04.97
A
Grid and distribution systems
AR
Protection equipment
Printout date 14. Mrz. 01
Page AR1 of AR1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : AS
04.04.97
A
Grid and distribution systems
AS
Decentralized panels and cabinets
ASA
Circuit breaker appurtenances
ASB
Multiplication, conversion, decoupling
ASC
Transducer appurtenances
ASD
Compressed air, hydraulics
ASJ
Automated controls, closed-loop control
ASL
Grid simulation, voltage group selection
ASM
Measuring equipment
ASN
Auxiliary power supply
ASP
Recording
ASQ
Metering
ASR
Protection
ASS
Synchronization
AST
Transformation
ASU
Panels and cabinets for auxiliary equipment
ASV
Group, intermediate and general terminal blocks
ASW
Indication, manual operation, monitoring
ASX
Alarm annunciation
Printout date 14. Mrz. 01
Page AS1 of AS1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : AT
04.04.97
A
Grid and distribution systems
AT
Transformer equipment
Printout date 14. Mrz. 01
Page AT1 of AT1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : AU
04.04.97
A
Grid and distribution systems
AU
Open-loop control, checkback and auxiliary equipment
Printout date 14. Mrz. 01
Page AU1 of AU1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : AV
04.04.97
A
Grid and distribution systems
AV
Marshalling racks
Printout date 14. Mrz. 01
Page AV1 of AV1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : AW
04.04.97
A
Grid and distribution systems
AW
Instrument panels
Printout date 14. Mrz. 01
Page AW1 of AW1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : AX
04.04.97
A
Grid and distribution systems
AX
Central equipment
Printout date 14. Mrz. 01
Page AX1 of AX1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : AY
04.04.97
A
Grid and distribution systems
AY
Communication equipment
AYA
Telephone system (PABX)
AYB
Control console telephone system
AYC
Alarm system (acoustic)
AYD
Alarm system (optical)
AYE
Fire alarm system
AYF
Clock system
AYG
Remote control system
AYH
Telemetry system
AYJ
Remote metering system
AYK
HF carrier telephone system
AYL
Staff paging system, wireless
AYM
Staff paging system, inductive
AYN
Staff paging system, hardwired
AYP
Optical monitoring system
AYQ
General gas detection system (if not assigned to specific system)
AYS
Radiotelephone system
Printout date 14. Mrz. 01
Page AY1 of AY1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : B
04.04.97
B
Power transmission and auxiliary power supply
BA
Power transmission
BB
Medium-voltage distribution boards and transformers, normal system
BC
Medium-voltage distribution boards and transformers, general-purpose
BD
Medium-voltage emergency distribution boards and transformers, (diesel)
emergency power system 1
BF
Low-voltage main distribution boards and transformers, normal system
BG
Low-voltage distribution boards and transformers, (may be used in addition to
*BF*, *BH*, *BJ*, *BK* and *BL*)
BH
Low-voltage main distribution boards and transformers, general-purpose
BJ
Low-voltage subdistribution boards and transformers, normal system
BK
Low-voltage distribution boards and transformers, (may be used in addition to
*BF*, *BG*, *BH*, *BJ* and *BL*)
BL
Low-voltage subdistribution boards and transformers, general-purpose (local
switchgear)
BM
Low-voltage distribution boards and transformers, (diesel) emergency power
system 1
BN
Low-voltage distribution boards and transformers, (diesel) emergency power
system 2 (protection against external impact)
BP
Power installations for variable-speed drives (e. g. for feedwater pump, excitation
equipment, not power adjusters in switchgear)
BR
Low-voltage distribution boards, uninterruptible (converter) power supply
BT
Battery systems
BU
DC distribution boards, normal system
BV
DC distribution boards, emergency power system 1
BW
DC distribution boards, emergency power system 2 (protection against external
impact)
BX
Fluid supply system for control and protection equipment
BY
Control and protection equipment
Printout date 14. Mrz. 01
Page B1 of B1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : BA
04.04.97
B
Power transmission and auxiliary power supply
BA
Power transmission
BAA
Generator leads
Limit: from excl. generator bushings, incl. current and voltage transformers,
cooling and ventilation systems
to excl. generator transformer low side bushings or
to excl. auxiliary power transformer high side bushings
BAB
Foundation cabinets
BAC
Generator circuit breaker, also commutating pole circuit breaker, incl. cooling
system
BAT
Generator transformers, including cooling system
BAU
Earthing and lightning protection systems
BAX
Control air supply system
BAY
Control and protection equipment
Printout date 14. Mrz. 01
Page BA1 of BA1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : BB
04.04.97
B
Power transmission and auxiliary power supply
BB
Medium-voltage distribution boards and transformers, normal system
BBA
MV distribution board
BBB
MV distribution board
BBC
MV distribution board
BBD
MV distribution board
BBE
MV distribution board
BBF
MV distribution board
BBG
MV distribution board
BBH
MV distribution board
BBJ
MV distribution board
BBK
MV distribution board
BBL
MV distribution board
BBM
MV distribution board
BBN
MV distribution board
BBP
MV distribution board
BBQ
MV distribution board
BBR
MV distribution board
BBS
MV distribution board
BBT
MV auxiliary power transformers
BBX
Fluid supply system for control and protection equipment
BBY
Control and protection equipment
Printout date 14. Mrz. 01
Page BB1 of BB1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : BC
04.04.97
B
Power transmission and auxiliary power supply
BC
Medium-voltage distribution boards and transformers, general-purpose
BCA
MV start-up distribution board
BCB
MV start-up distribution board
BCC
MV start-up distribution board
BCD
MV start-up distribution board
BCE
MV start-up distribution board
BCF
MV start-up distribution board
BCG
MV start-up distribution board
BCH
MV start-up distribution board
BCJ
MV start-up distribution board
BCK
MV start-up distribution board
BCL
MV start-up distribution board
BCM
MV start-up distribution board
BCN
MV start-up distribution board
BCP
MV start-up distribution board
BCQ
MV start-up distribution board
BCR
MV start-up distribution board
BCS
MV start-up distribution board
BCT
Start-up, offsite, general-purpose transformers
BCX
Fluid supply system for control and protection equipment
BCY
Control and protection equipment
Printout date 14. Mrz. 01
Page BC1 of BC1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : BD
04.04.97
B
Power transmission and auxiliary power supply
BD
Medium-voltage emergency distribution boards and transformers, (diesel)
emergency power system 1
BDA
MV emergency distribution board
BDB
MV emergency distribution board
BDC
MV emergency distribution board
BDD
MV emergency distribution board
BDE
MV emergency distribution board
BDF
MV emergency distribution board
BDG
MV emergency distribution board
BDH
MV emergency distribution board
BDJ
MV emergency distribution board
BDK
MV emergency distribution board
BDL
MV emergency distribution board
BDM
MV emergency distribution board
BDN
MV emergency distribution board
BDP
MV emergency distribution board
BDQ
MV emergency distribution board
BDR
MV emergency distribution board
BDS
MV emergency distribution board
BDT
MV transformator
BDX
Fluid supply system for control and protection equipment
BDY
Control and protection equipment
Printout date 14. Mrz. 01
Page BD1 of BD1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : BF
04.04.97
B
Power transmission and auxiliary power supply
BF
Low-voltage main distribution boards and transformers, normal system
BFA
LV main distribution board
BFB
LV main distribution board
BFC
LV main distribution board
BFD
LV main distribution board
BFE
LV main distribution board
BFF
LV main distribution board
BFG
LV main distribution board
BFH
LV main distribution board
BFJ
LV main distribution board
BFK
LV main distribution board
BFL
LV main distribution board
BFM
LV main distribution board
BFN
LV main distribution board
BFP
LV main distribution board
BFQ
LV main distribution board
BFR
LV main distribution board
BFS
LV main distribution board
BFT
LV auxiliary power transformer
BFU
LV auxiliary power transformer
BFV
LV auxiliary power transformer
BFW
LV auxiliary power transformer
BFX
Fluid supply system for control and protection equipment
BFY
Control and protection equipment
Printout date 14. Mrz. 01
Page BF1 of BF1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : BG
04.04.97
B
Power transmission and auxiliary power supply
BG
Low-voltage distribution boards and transformers, (may be used in addition to
*BF*, *BH*, *BJ*, *BK* and *BL*)
BGA
LV distribution board
BGB
LV distribution board
BGC
LV distribution board
BGD
LV distribution board
BGE
LV distribution board
BGF
LV distribution board
BGG
LV distribution board
BGH
LV distribution board
BGJ
LV distribution board
BGK
LV distribution board
BGL
LV distribution board
BGM
LV distribution board
BGN
LV distribution board
BGP
LV distribution board
BGQ
LV distribution board
BGR
LV distribution board
BGS
LV distribution board
BGT
LV auxiliary power transformer
BGU
LV auxiliary power transformer
BGV
LV auxiliary power transformer
BGW
LV auxiliary power transformer
BGX
Fluid supply system for control and protection equipment
BGY
Control and protection equipment
Printout date 14. Mrz. 01
Page BG1 of BG1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : BH
04.04.97
B
Power transmission and auxiliary power supply
BH
Low-voltage main distribution boards and transformers, general-purpose
BHA
LV main distribution board
BHB
LV main distribution board
BHC
LV main distribution board
BHD
LV main distribution board
BHE
LV main distribution board
BHF
LV main distribution board
BHG
LV main distribution board
BHH
LV main distribution board
BHJ
LV main distribution board
BHK
LV main distribution board
BHL
LV main distribution board
BHM
LV main distribution board
BHN
LV main distribution board
BHP
LV main distribution board
BHQ
LV main distribution board
BHR
LV main distribution board
BHS
LV main distribution board
BHT
LV auxiliary power transformer
BHU
LV auxiliary power transformer
BHV
LV auxiliary power transformer
BHW
LV auxiliary power transformer
BHX
Fluid supply system for control and protection equipment
BHY
Control and protection equipment
Printout date 14. Mrz. 01
Page BH1 of BH1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : BJ
04.04.97
B
Power transmission and auxiliary power supply
BJ
Low-voltage subdistribution boards and transformers, normal system
BJA
LV sudistribution board
BJB
LV sudistribution board
BJC
LV sudistribution board
BJD
LV sudistribution board
BJE
LV sudistribution board
BJF
LV sudistribution board
BJG
LV sudistribution board
BJH
LV sudistribution board
BJJ
LV sudistribution board
BJK
LV sudistribution board
BJL
LV sudistribution board
BJM
LV sudistribution board
BJN
LV sudistribution board
BJP
LV sudistribution board
BJQ
LV sudistribution board
BJR
LV sudistribution board
BJS
LV sudistribution board
BJT
LV auxiliary power transformer
BJX
Fluid supply system for control and protection equipment
BJY
Control and protection equipment
Printout date 14. Mrz. 01
Page BJ1 of BJ1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : BK
04.04.97
B
Power transmission and auxiliary power supply
BK
Low-voltage distribution boards and transformers, (may be used in addition to
*BF*, *BG*, *BH*, *BJ* and *BL*)
BKA
LV distribution board
BKB
LV distribution board
BKC
LV distribution board
BKD
LV distribution board
BKE
LV distribution board
BKF
LV distribution board
BKG
LV distribution board
BKH
LV distribution board
BKJ
LV distribution board
BKK
LV distribution board
BKL
LV distribution board
BKM
LV distribution board
BKN
LV distribution board
BKP
LV distribution board
BKQ
LV distribution board
BKR
LV distribution board
BKS
LV distribution board
BKT
LV auxiliary power transformer
BKU
LV auxiliary power transformer
BKV
LV auxiliary power transformer
BKW
LV auxiliary power transformer
BKX
Fluid supply system for control and protection equipment
BKY
Control and protection equipment
Printout date 14. Mrz. 01
Page BK1 of BK1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : BL
04.04.97
B
Power transmission and auxiliary power supply
BL
Low-voltage subdistribution boards and transformers, general-purpose (local
switchgear)
BLA
LV subdistribution board
BLB
LV subdistribution board
BLC
LV subdistribution board
BLD
LV subdistribution board
BLE
LV subdistribution board
BLF
LV subdistribution board
BLG
LV subdistribution board
BLH
LV subdistribution board
BLJ
LV subdistribution board
BLK
LV subdistribution board
BLL
LV subdistribution board
BLM
LV subdistribution board
BLN
LV subdistribution board
BLP
LV subdistribution board
BLQ
LV subdistribution board
BLR
LV subdistribution board
BLS
LV subdistribution board
BLT
LV auxiliary power transformer
BLX
Fluid supply system for control and protection equipment
BLY
Control and protection equipment
Printout date 14. Mrz. 01
Page BL1 of BL1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : BM
04.04.97
B
Power transmission and auxiliary power supply
BM
Low-voltage distribution boards and transformers, (diesel) emergency power
system 1
BMA
LV emergency distribution board
BMB
LV emergency distribution board
BMC
LV emergency distribution board
BMD
LV emergency distribution board
BME
LV emergency distribution board
BMF
LV emergency distribution board
BMG
LV emergency distribution board
BMH
LV emergency distribution board
BMJ
LV emergency distribution board
BMK
LV emergency distribution board
BML
LV emergency distribution board
BMM
LV emergency distribution board
BMN
LV emergency distribution board
BMP
LV emergency distribution board
BMQ
LV emergency distribution board
BMR
LV emergency distribution board
BMS
LV emergency distribution board
BMT
LV auxiliary power transformer
BMU
LV auxiliary power transformer
BMV
LV auxiliary power transformer
BMW
LV auxiliary power transformer
BMX
Fluid supply system for control and protection equipment
BMY
Control and protection equipment
Printout date 14. Mrz. 01
Page BM1 of BM1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : BN
04.04.97
B
Power transmission and auxiliary power supply
BN
Low-voltage distribution boards and transformers, (diesel) emergency power
system 2 (protection against external impact)
BNA
LV distribution board
BNB
LV distribution board
BNC
LV distribution board
BND
LV distribution board
BNE
LV distribution board
BNF
LV distribution board
BNG
LV distribution board
BNH
LV distribution board
BNJ
LV distribution board
BNK
LV distribution board
BNL
LV distribution board
BNM
LV distribution board
BNN
LV distribution board
BNP
LV distribution board
BNQ
LV distribution board
BNR
LV distribution board
BNS
LV distribution board
BNT
LV auxiliary power transformer
BNU
LV auxiliary power transformer
BNV
LV auxiliary power transformer
BNW
LV auxiliary power transformer
BNX
Fluid supply system for control and protection equipment
BNY
Control and protection equipment
Printout date 14. Mrz. 01
Page BN1 of BN1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : BP
04.04.97
B
Power transmission and auxiliary power supply
BP
Power installations for variable-speed drives (e. g. for feedwater pump, excitation
equipment, not power adjusters in switchgear)
BPA
Power installations for variable-speed drives
BPB
Power installations for variable-speed drives
BPC
Power installations for variable-speed drives
BPD
Power installations for variable-speed drives
BPE
Power installations for variable-speed drives
BPF
Power installations for variable-speed drives
BPG
Power installations for variable-speed drives
BPH
Power installations for variable-speed drives
BPJ
Power installations for variable-speed drives
BPK
Power installations for variable-speed drives
BPL
Power installations for variable-speed drives
BPM
Power installations for variable-speed drives
BPN
Power installations for variable-speed drives
BPP
Power installations for variable-speed drives
BPQ
Power installations for variable-speed drives
BPR
Power installations for variable-speed drives
BPS
Power installations for variable-speed drives
BPT
Power installations for variable-speed drives
BPU
Power installations for variable-speed drives
BPX
Fluid supply system for control and protection equipment
BPY
Control and protection equipment
Printout date 14. Mrz. 01
Page BP1 of BP1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : BR
04.04.97
B
Power transmission and auxiliary power supply
BR
Low-voltage distribution boards, uninterruptible (converter) power supply
BRA
LV distribution board, uninterruptible (converter) power supply
BRB
LV distribution board, uninterruptible (converter) power supply
BRC
LV distribution board, uninterruptible (converter) power supply
BRD
LV distribution board, uninterruptible (converter) power supply
BRE
LV distribution board, uninterruptible (converter) power supply
BRF
LV distribution board, uninterruptible (converter) power supply
BRG
LV distribution board, uninterruptible (converter) power supply
BRH
LV distribution board, uninterruptible (converter) power supply
BRJ
LV distribution board, uninterruptible (converter) power supply
BRK
LV distribution board, uninterruptible (converter) power supply
BRL
LV distribution board, uninterruptible (converter) power supply
BRM
LV distribution board, uninterruptible (converter) power supply
BRN
LV distribution board, uninterruptible (converter) power supply
BRP
LV distribution board, uninterruptible (converter) power supply
BRQ
LV distribution board, uninterruptible (converter) power supply
BRR
LV distribution board, uninterruptible (converter) power supply
BRS
LV distribution board, uninterruptible (converter) power supply
BRT
Converter (rotary)
BRU
Converter (static), inverter
BRV
Emergency power generating equipment (if not under *X* = Heavy Machinery)
BRX
Fluid supply system for control and protection equipment
BRY
Control and protection equipment
Printout date 14. Mrz. 01
Page BR1 of BR1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : BT
04.04.97
B
Power transmission and auxiliary power supply
BT
Battery systems
BTA
Batteries
BTB
Batteries
BTC
Batteries
BTD
Batteries
BTE
Batteries
BTF
Batteries
BTG
Batteries
BTH
Batteries
BTJ
Batteries
BTK
Batteries
BTL
Rectifiers, battery chargers
BTM
Rectifiers, battery chargers
BTN
Rectifiers, battery chargers
BTP
Rectifiers, battery chargers
BTQ
Rectifiers, battery chargers
BTR
Rectifiers, battery chargers
BTS
Rectifiers, battery chargers
BTT
Rectifiers, battery chargers
BTU
Rectifiers, battery chargers
BTV
Rectifiers, battery chargers
BTW
Common equipment
BTX
Common equipment
BTY
Common equipment
BTZ
Common equipment
Printout date 14. Mrz. 01
Page BT1 of BT1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : BU
04.04.97
B
Power transmission and auxiliary power supply
BU
DC distribution boards, normal system
BUA
DC distribution board
BUB
DC distribution board
BUC
DC distribution board
BUD
DC distribution board
BUE
DC distribution board
BUF
DC distribution board
BUG
DC distribution board
BUH
DC distribution board
BUJ
DC distribution board
BUK
DC distribution board
BUL
DC distribution board
BUM
DC distribution board
BUN
DC distribution board
BUP
DC distribution board
BUQ
DC distribution board
BUR
DC distribution board
BUS
DC distribution board
BUX
Fluid supply system for control and protection equipment
BUY
Control and protection equipment
Printout date 14. Mrz. 01
Page BU1 of BU1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : BV
04.04.97
B
Power transmission and auxiliary power supply
BV
DC distribution boards, emergency power system 1
BVA
DC distribution board
BVB
DC distribution board
BVC
DC distribution board
BVD
DC distribution board
BVE
DC distribution board
BVF
DC distribution board
BVG
DC distribution board
BVH
DC distribution board
BVJ
DC distribution board
BVK
DC distribution board
BVL
DC distribution board
BVM
DC distribution board
BVN
DC distribution board
BVP
DC distribution board
BVQ
DC distribution board
BVR
DC distribution board
BVS
DC distribution board
BVX
Fluid supply system for control and protection equipment
BVY
Control and protection equipment
Printout date 14. Mrz. 01
Page BV1 of BV1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : BW
04.04.97
B
Power transmission and auxiliary power supply
BW
DC distribution boards, emergency power system 2 (protection against external
impact)
BWA
DC distribution board
BWB
DC distribution board
BWC
DC distribution board
BWD
DC distribution board
BWE
DC distribution board
BWF
DC distribution board
BWG
DC distribution board
BWH
DC distribution board
BWJ
DC distribution board
BWK
DC distribution board
BWL
DC distribution board
BWM
DC distribution board
BWN
DC distribution board
BWP
DC distribution board
BWQ
DC distribution board
BWR
DC distribution board
BWS
DC distribution board
BWX
Fluid supply system for control and protection equipment
BWY
Control and protection equipment
Printout date 14. Mrz. 01
Page BW1 of BW1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : BX
04.04.97
B
Power transmission and auxiliary power supply
BX
Fluid supply system for control and protection equipment
BXA
Fluid supply system for control and protection equipment
BXB
Fluid supply system for control and protection equipment
BXC
Fluid supply system for control and protection equipment
BXD
Fluid supply system for control and protection equipment
BXE
Fluid supply system for control and protection equipment
BXF
Fluid supply system for control and protection equipment
BXG
Fluid supply system for control and protection equipment
BXH
Fluid supply system for control and protection equipment
BXJ
Fluid supply system for control and protection equipment
BXK
Fluid supply system for control and protection equipment
BXL
Fluid supply system for control and protection equipment
BXM
Fluid supply system for control and protection equipment
BXN
Fluid supply system for control and protection equipment
BXP
Fluid supply system for control and protection equipment
BXQ
Fluid supply system for control and protection equipment
BXR
Fluid supply system for control and protection equipment
BXS
Fluid supply system for control and protection equipment
BXT
Fluid supply system for control and protection equipment
BXU
Fluid supply system for control and protection equipment
Printout date 14. Mrz. 01
Page BX1 of BX1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : BY
04.04.97
B
Power transmission and auxiliary power supply
BY
Control and protection equipment
BYA
Control and protection equipment
BYB
Control and protection equipment
BYC
Control and protection equipment
BYD
Control and protection equipment
BYE
Control and protection equipment
BYF
Control and protection equipment
BYG
Control and protection equipment
BYH
Control and protection equipment
BYJ
Control and protection equipment
BYK
Control and protection equipment
BYL
Control and protection equipment
BYM
Control and protection equipment
BYN
Control and protection equipment
BYP
Control and protection equipment
BYQ
Control and protection equipment
BYR
Control and protection equipment
BYS
Control and protection equipment
BYT
Control and protection equipment
BYU
Control and protection equipment
Printout date 14. Mrz. 01
Page BY1 of BY1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : C
04.04.97
C
Instrumentation and control equipment
CA
Protective interlocks
CB
Functional group control, subloop control
CC
Binary signal conditioning
CD
Drive control interface
CE
Annunciation
CF
Measurement, recording
CG
Closed-loop control (excl. power section)
CH
Protection (excl. reactor protection)
CJ
Unit coordination level
CK
Process computer system
CL
Reactor protection
CR
Programmable process control systems and associated cabinets
CU
Closed-loop control (power section)
CV
Marshalling racks
CW
Control rooms
CX
Local control stations (e. g. for solid fuel supply system, ash removal system,
cooling water system, diesel engine plant, monitoring of generator cooling,
emergency control station)
CY
Communication equipment
Printout date 14. Mrz. 01
Page C1 of C1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : CA
04.04.97
C
Instrumentation and control equipment
CA
Protective interlocks
CAA
Cabinets for protective interlocks
CAB
Cabinets for protective interlocks
CAC
Cabinets for protective interlocks
CAD
Cabinets for protective interlocks
CAE
Cabinets for protective interlocks
CAF
Cabinets for protective interlocks
CAG
Cabinets for protective interlocks
CAH
Cabinets for protective interlocks
CAJ
Cabinets for protective interlocks
CAK
Cabinets for protective interlocks
CAL
Cabinets for protective interlocks
CAM
Cabinets for protective interlocks
CAN
Cabinets for protective interlocks
CAP
Cabinets for protective interlocks
CAQ
Cabinets for protective interlocks
CAR
Cabinets for protective interlocks, installation in the secured area (of nuclear
power plant)
CAS
Cabinets for protective interlocks, installation in the secured area (of nuclear
power plant)
CAT
Cabinets for protective interlocks, installation in the secured area (of nuclear
power plant)
CAU
Cabinets for protective interlocks, installation in the secured area (of nuclear
power plant)
CAV
Cabinets for protective interlocks, installation in the secured area (of nuclear
power plant)
CAW
Cabinets for protective interlocks, installation in the secured area (of nuclear
power plant)
CAX
Cabinets for protective interlocks, installation in the secured area (of nuclear
power plant)
CAY
Cabinets for protective interlocks, installation in the secured area (of nuclear
power plant)
Printout date 14. Mrz. 01
Page CA1 of CA1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : CB
04.04.97
C
Instrumentation and control equipment
CB
Functional group control, subloop control
CBA
Cabinets for functional group control
CBB
Cabinets for functional group control
CBC
Cabinets for functional group control
CBD
Cabinets for functional group control
CBE
Cabinets for functional group control
CBF
Cabinets for functional group control
CBG
Cabinets for functional group control
CBH
Cabinets for functional group control
CBJ
Cabinets for functional group control
CBK
Cabinets for functional group control
CBL
Cabinets for functional group control
CBM
Cabinets for functional group control
CBN
Cabinets for functional group control
CBP
Cabinets for synchronization
CBQ
Cabinets for auxiliary power changeover
CBR
Cabinets for functional group control, installation in the secured area (of nuclear
power plant)
CBS
Cabinets for functional group control, installation in the secured area (of nuclear
power plant)
CBT
Cabinets for functional group control, installation in the secured area (of nuclear
power plant)
CBU
Cabinets for functional group control, installation in the secured area (of nuclear
power plant)
CBV
Cabinets for functional group control, installation in the secured area (of nuclear
power plant)
CBW
Cabinets for functional group control, installation in the secured area (of nuclear
power plant)
CBX
Cabinets for functional group control, installation in the secured area (of nuclear
power plant)
CBY
Cabinets for functional group control, installation in the secured area (of nuclear
power plant)
Printout date 14. Mrz. 01
Page CB1 of CB1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : CC
04.04.97
C
Instrumentation and control equipment
CC
Binary signal conditioning
CCA
Cabinets for binary signal conditioning
CCB
Cabinets for binary signal conditioning
CCC
Cabinets for binary signal conditioning
CCD
Cabinets for binary signal conditioning
CCE
Cabinets for binary signal conditioning
CCF
Cabinets for binary signal conditioning
CCG
Cabinets for binary signal conditioning
CCH
Cabinets for binary signal conditioning
CCJ
Cabinets for binary signal conditioning
CCK
Cabinets for binary signal conditioning
CCL
Cabinets for binary signal conditioning
CCM
Cabinets for binary signal conditioning
CCN
Cabinets for binary signal conditioning
CCP
Cabinets for binary signal conditioning
CCQ
Cabinets for binary signal conditioning
CCR
Cabinets for binary signal conditioning, installation in the secured area (of nuclear
power plant)
CCS
Cabinets for binary signal conditioning, installation in the secured area (of nuclear
power plant)
CCT
Cabinets for binary signal conditioning, installation in the secured area (of nuclear
power plant)
CCU
Cabinets for binary signal conditioning, installation in the secured area (of nuclear
power plant)
CCV
Cabinets for binary signal conditioning, installation in the secured area (of nuclear
power plant)
CCW
Cabinets for binary signal conditioning, installation in the secured area (of nuclear
power plant)
CCX
Cabinets for binary signal conditioning, installation in the secured area (of nuclear
power plant)
CCY
Cabinets for binary signal conditioning, installation in the secured area (of nuclear
power plant)
Printout date 14. Mrz. 01
Page CC1 of CC1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : CD
04.04.97
C
Instrumentation and control equipment
CD
Drive control interface
CDA
Cabinets for drive control interface
CDB
Cabinets for drive control interface
CDC
Cabinets for drive control interface
CDD
Cabinets for drive control interface
CDE
Cabinets for drive control interface
CDF
Cabinets for drive control interface
CDG
Cabinets for drive control interface
CDH
Cabinets for drive control interface
CDJ
Cabinets for drive control interface
CDK
Cabinets for drive control interface
CDL
Cabinets for drive control interface
CDM
Cabinets for drive control interface
CDN
Cabinets for drive control interface
CDP
Cabinets for drive control interface
CDQ
Cabinets for drive control interface
CDR
Cabinets for drive control interface, installation in the secured area (of nuclear
power plant)
CDS
Cabinets for drive control interface, installation in the secured area (of nuclear
power plant)
CDT
Cabinets for drive control interface, installation in the secured area (of nuclear
power plant)
CDU
Cabinets for drive control interface, installation in the secured area (of nuclear
power plant)
CDV
Cabinets for drive control interface, installation in the secured area (of nuclear
power plant)
CDW
Cabinets for drive control interface, installation in the secured area (of nuclear
power plant)
CDX
Cabinets for drive control interface, installation in the secured area (of nuclear
power plant)
CDY
Cabinets for drive control interface, installation in the secured area (of nuclear
power plant)
Printout date 14. Mrz. 01
Page CD1 of CD1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : CE
04.04.97
C
Instrumentation and control equipment
CE
Annunciation
CEA
Cabinets for annunciation systems
CEB
Cabinets for annunciation systems
CEC
Cabinets for annunciation systems
CED
Cabinets for annunciation systems
CEE
Cabinets for annunciation systems
CEF
Cabinets for annunciation systems
CEG
Cabinets for annunciation systems
CEH
Cabinets for annunciation systems
CEJ
Fault recording
CEK
Fault recording
CEL
Fault recording
CEM
Fault recording
CEN
Fault recording
CEP
Fault recording
CEQ
Fault recording
CER
Cabinets for annunciation systems, installation in the secured area (of nuclear
power plant)
CES
Cabinets for annunciation systems, installation in the secured area (of nuclear
power plant)
CET
Cabinets for annunciation systems, installation in the secured area (of nuclear
power plant)
CEU
Cabinets for annunciation systems, installation in the secured area (of nuclear
power plant)
CEV
Cabinets for annunciation systems, installation in the secured area (of nuclear
power plant)
CEW
Cabinets for annunciation systems, installation in the secured area (of nuclear
power plant)
CEX
Cabinets for annunciation systems, installation in the secured area (of nuclear
power plant)
CEY
Cabinets for annunciation systems, installation in the secured area (of nuclear
power plant)
Printout date 14. Mrz. 01
Page CE1 of CE1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : CF
04.04.97
C
Instrumentation and control equipment
CF
Measurement, recording
CFA
Cabinets for measurement
CFB
Cabinets for measurement
CFC
Cabinets for measurement
CFD
Cabinets for measurement
CFE
Cabinets for measurement
CFF
Cabinets for measurement
CFG
Cabinets for reactor instrumentation
CFH
Cabinets for reactor instrumentation
CFJ
Cabinets for reactor instrumentation
CFK
Cabinets for reactor instrumentation
CFL
Cabinets for radiation measurement
CFM
Cabinets for radiation measurement
CFN
Cabinets for radiation measurement
CFP
Cabinets for radiation measurement
CFQ
Cabinets for recording (meters, pen recorders)
CFR
Cabinets for measurement, installation in the secured area (of nuclear power
plant)
CFS
Cabinets for measurement, installation in the secured area (of nuclear power
plant)
CFT
Cabinets for measurement, installation in the secured area (of nuclear power
plant)
CFU
Cabinets for measurement, installation in the secured area (of nuclear power
plant)
CFV
Cabinets for measurement, installation in the secured area (of nuclear power
plant)
CFW
Cabinets for measurement, installation in the secured area (of nuclear power
plant)
CFX
Cabinets for measurement, installation in the secured area (of nuclear power
plant)
CFY
Cabinets for measurement, installation in the secured area (of nuclear power
plant)
Printout date 14. Mrz. 01
Page CF1 of CF1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : CG
04.04.97
C
Instrumentation and control equipment
CG
Closed-loop control (excl. power section)
CGA
Cabinets for closed-loop control
CGB
Cabinets for closed-loop control
CGC
Cabinets for closed-loop control
CGD
Cabinets for closed-loop control
CGE
Cabinets for closed-loop control
CGF
Cabinets for closed-loop control
CGG
Cabinets for closed-loop control
CGH
Cabinets for closed-loop control
CGJ
Cabinets for reactor control
CGK
Cabinets for reactor control
CGL
Cabinets for reactor control
CGM
Cabinets for reactor control
CGN
Cabinets for reactor control
CGP
Cabinets for reactor control
CGQ
Cabinets for reactor control
CGR
Cabinets for closed-loop control, installation in the secured area (of nuclear power
plant)
CGS
Cabinets for closed-loop control, installation in the secured area (of nuclear power
plant)
CGT
Cabinets for closed-loop control, installation in the secured area (of nuclear power
plant)
CGU
Cabinets for closed-loop control, installation in the secured area (of nuclear power
plant)
CGV
Cabinets for closed-loop control, installation in the secured area (of nuclear power
plant)
CGW
Cabinets for closed-loop control, installation in the secured area (of nuclear power
plant)
CGX
Cabinets for closed-loop control, installation in the secured area (of nuclear power
plant)
CGY
Cabinets for closed-loop control, installation in the secured area (of nuclear power
plant)
Printout date 14. Mrz. 01
Page CG1 of CG1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : CH
04.04.97
C
Instrumentation and control equipment
CH
Protection (excl. reactor protection)
CHA
Cabinets for generator and transformer protection
CHB
Cabinets for generator and transformer protection
CHC
Cabinets for generator and transformer protection
CHD
Cabinets for generator and transformer protection
CHE
Cabinets for protection (excl. reactor protection)
CHF
Cabinets for protection (excl. reactor protection)
CHG
Cabinets for protection (excl. reactor protection)
CHH
Cabinets for protection (excl. reactor protection)
CHJ
Cabinets for protection (excl. reactor protection)
CHK
Cabinets for protection (excl. reactor protection)
CHL
Cabinets for protection (excl. reactor protection)
CHM
Cabinets for protection (excl. reactor protection)
CHN
Cabinets for protection (excl. reactor protection)
CHP
Cabinets for protection (excl. reactor protection)
CHQ
Cabinets for protection (excl. reactor protection)
CHR
Cabinets for protection (excl. reactor protection)
CHS
Cabinets for protection (excl. reactor protection)
CHT
Cabinets for protection (excl. reactor protection)
CHU
Cabinets for protection (excl. reactor protection)
CHV
Cabinets for protection (excl. reactor protection)
CHW
Cabinets for protection (excl. reactor protection)
CHX
Cabinets for protection (excl. reactor protection)
CHY
Cabinets for protection (excl. reactor protection)
Printout date 14. Mrz. 01
Page CH1 of CH1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : CJ
04.04.97
C
Instrumentation and control equipment
CJ
Unit coordination level
CJA
Unit control system (including cabinets)
CJD
Start-up control, setpoint control (unit) (incl. cabinets)
CJF
Boiler control system (incl. cabinets)
CJJ
Instrumentation and control cabinets for steam turbine set
CJK
Instrumentation and control cabinets for steam turbine set
CJL
Instrumentation and control cabinets for steam turbine set
CJM
Instrumentation and control cabinets for steam turbine set
CJN
Instrumentation and control cabinets for steam turbine set
CJP
Instrumentation and control cabinets for gas turbine set
CJQ
Instrumentation and control cabinets for gas turbine set
CJR
Instrumentation and control cabinets for gas turbine set
CJS
Instrumentation and control cabinets for gas turbine set
CJT
Instrumentation and control cabinets for gas turbine set
CJU
Instrumentation and control cabinets for other main and heavy machinery
CJV
Instrumentation and control cabinets for other main and heavy machinery
CJW
Instrumentation and control cabinets for other main and heavy machinery
CJX
Instrumentation and control cabinets for other main and heavy machinery
CJY
Instrumentation and control cabinets for other main and heavy machinery
Printout date 14. Mrz. 01
Page CJ1 of CJ1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : CK
04.04.97
C
Instrumentation and control equipment
CK
Process computer system
CKA
Online supervisory and diagnostic computer
CKB
Online supervisory and diagnostic computer
CKC
Online supervisory and diagnostic computer
CKD
Online supervisory and diagnostic computer
CKE
Online supervisory and diagnostic computer
CKF
Online supervisory and diagnostic computer
CKG
Online supervisory and diagnostic computer
CKH
Online supervisory and diagnostic computer
CKJ
Access control computer
CKK
Access control computer
CKL
Access control computer
CKM
Access control computer
CKN
Process computer system
CKP
Process computer system
CKQ
Process computer system
CKR
Process computer system
CKS
Process computer system
CKT
Process computer system
CKU
Process computer system
CKV
Process computer system
CKW
Process computer system
CKX
Process computer system
CKY
Process computer system
Printout date 14. Mrz. 01
Page CK1 of CK1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : CL
04.04.97
C
Instrumentation and control equipment
CL
Reactor protection
CLA
Cabinets for reactor protection
CLB
Cabinets for reactor protection
CLC
Cabinets for reactor protection
CLD
Cabinets for reactor protection
CLE
Cabinets for reactor protection
CLF
Cabinets for reactor protection
CLG
Cabinets for reactor protection
CLH
Cabinets for reactor protection
CLJ
Cabinets for reactor protection
CLK
Cabinets for reactor protection
CLL
Cabinets for reactor protection
CLM
Cabinets for reactor protection
CLN
Cabinets for reactor protection
CLP
Cabinets for reactor protection
CLQ
Cabinets for reactor protection
CLR
Cabinets for reactor protection
CLS
Cabinets for reactor protection
CLT
Cabinets for reactor protection
CLU
Cabinets for reactor protection
CLV
Cabinets for reactor protection
CLW
Cabinets for reactor protection
CLX
Cabinets for reactor protection
CLY
Cabinets for reactor protection
Printout date 14. Mrz. 01
Page CL1 of CL1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : CR
04.04.97
C
Instrumentation and control equipment
CR
Programmable process control systems and associated cabinets
CRA
Cabinets for automation systems, e. g. unit control level, function unit 1
CRB
Cabinets for automation systems, function unit 2
CRC
Cabinets for automation systems, function unit 3
CRD
Cabinets for automation systems, function unit 4
CRE
Cabinets for automation systems, function unit 5
CRF
Cabinets for automation systems, function unit 6
CRG
Cabinets for automation systems, function unit 7
CRK
Cabinets for automation systems, e. g. several function units
CRN
Automation systems, e. g. operational
CRP
Automation systems, e. g. fail-safe
CRQ
Automation systems, e. g. AS620-T
CRR
Communications systems, e. g. terminal bus system
CRS
Communications systems, e. g. plant bus system
CRT
Communications systems, e. g. field bus system
CRU
Process control and information system, e. g. OM650
CRV
Configuring system, e. g. ES680
CRW
Diagnostics system, e. g. DS670
CRY
Common superordinate systems
Printout date 14. Mrz. 01
Page CR1 of CR1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : CU
04.04.97
C
Instrumentation and control equipment
CU
Closed-loop control (power section)
CUA
Cabinets for power adjuster 400V AC, e. g. function unit 1
CUB
Cabinets for power adjuster 400V AC, e. g. function unit 2
CUC
Cabinets for power adjuster 400V AC, e. g. function unit 3
CUD
Cabinets for power adjuster 400V AC, e. g. function unit 4
CUE
Cabinets for power adjuster 400V AC, e. g. function unit 5
CUF
Cabinets for power adjuster 400V AC, e. g. function unit 6
CUG
Cabinets for power adjuster 400V AC, e. g. function unit 7
CUH
Cabinets for power adjuster
CUJ
Cabinets for power adjuster
CUK
Cabinets for power adjuster
CUL
Cabinets for interposing relays for 24 V DC solenoid valves
CUM
Cabinets for power supply of hardwired control room
CUN
Cabinets for 24 V DC fuses
CUP
Cabinets for 230 V DC fuses
CUQ
Cabinets for power adjuster
CUR
Cabinets for power adjuster, installation in the secured area (of nuclear power
plant)
CUS
Cabinets for power adjuster, installation in the secured area (of nuclear power
plant)
CUT
Cabinets for power adjuster, installation in the secured area (of nuclear power
plant)
CUU
Cabinets for power adjuster, installation in the secured area (of nuclear power
plant)
CUV
Cabinets for power adjuster, installation in the secured area (of nuclear power
plant)
CUW
Cabinets for power adjuster, installation in the secured area (of nuclear power
plant)
CUX
Cabinets for power adjuster, installation in the secured area (of nuclear power
plant)
CUY
Cabinets for power adjuster, installation in the secured area (of nuclear power
plant)
Printout date 14. Mrz. 01
Page CU1 of CU1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : CV
04.04.97
C
Instrumentation and control equipment
CV
Marshalling racks
CVA
Marshalling racks
CVB
Marshalling racks
CVC
Marshalling racks
CVD
Marshalling racks
CVE
Marshalling racks
CVF
Marshalling racks
CVG
Marshalling racks
CVH
Marshalling racks
CVJ
Marshalling racks
CVK
Marshalling racks
CVL
Marshalling racks
CVM
Marshalling racks
CVN
Marshalling racks
CVP
Marshalling racks
CVQ
Marshalling racks
CVR
Marshalling racks
CVS
Marshalling racks
CVT
Marshalling racks
CVU
Marshalling racks
CVV
Marshalling racks
CVW
Marshalling racks
CVX
Marshalling racks
CVY
Marshalling racks
Printout date 14. Mrz. 01
Page CV1 of CV1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : CW
04.04.97
C
Instrumentation and control equipment
CW
Control rooms
CWA
Main control consoles
CWB
Main control consoles
CWC
Main control consoles
CWD
Main control consoles
CWE
Main control consoles
CWF
Main control panels
CWG
Main control panels
CWH
Main control panels
CWJ
Main control panels
CWK
Main control panels
CWL
Main control panels
CWM
Main control panels
CWN
Main control panels
CWP
Main control panels
CWQ
Consoles and panels in control rooms
CWR
Consoles and panels in control rooms
CWS
Consoles and panels in control rooms
CWT
Consoles and panels in control rooms
CWU
Consoles and panels in control rooms
CWV
Consoles and panels in control rooms
CWW
Consoles and panels in control rooms
CWX
Consoles and panels in control rooms
CWY
Consoles and panels in control rooms
Printout date 14. Mrz. 01
Page CW1 of CW1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : CX
04.04.97
C
Instrumentation and control equipment
CX
Local control stations (e. g. for solid fuel supply system, ash removal system,
cooling water system, diesel engine plant, monitoring of generator cooling,
emergency control station)
CXA
Local control station
CXB
Local control station
CXC
Local control station
CXD
Local control station
CXE
Local control station
CXF
Local control station
CXG
Local control station
CXH
Local control station
CXJ
Local control station
CXK
Local control station
CXL
Local control station
CXM
Local control station
CXN
Local control station
CXP
Local control station
CXQ
Local control station
CXR
Local control station
CXS
Local control station
CXT
Local control station
CXU
Local control station
CXV
Local control station
CXW
Local control station
CXX
Local control station
CXY
Local control station
Printout date 14. Mrz. 01
Page CX1 of CX1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : CY
04.04.97
C
Instrumentation and control equipment
CY
Communication equipment
CYA
Telephone system (PABX)
CYB
Control console telephone system
CYC
Alarm system (acoustic)
CYD
Alarm system (optical)
CYE
Fire alarm system
CYF
Clock system
CYG
Remote control system
CYH
Telemetry system
CYJ
Remote metering system
CYK
HF carrier telephone system
CYL
Staff paging system, wireless
CYM
Staff paging system, inductive
CYN
Staff paging system, hardwired
CYP
Optical monitoring system (Plant TV system)
CYQ
General gas detection system (if not assigned to specific system)
CYR
Pneumatic tube conveyor
CYS
Radiotelephone system
CYY
Telephone system for commissioning
Printout date 14. Mrz. 01
Page CY1 of CY1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : D
04.04.97
D
Instrumentation and control equipment
DA
Instrumentation and control equipment
DB
Instrumentation and control equipment
DC
Instrumentation and control equipment
DD
Instrumentation and control equipment
DE
Instrumentation and control equipment
DF
Instrumentation and control equipment
DG
Instrumentation and control equipment
DH
Instrumentation and control equipment
DJ
Instrumentation and control equipment
DK
Instrumentation and control equipment
DL
Instrumentation and control equipment
DM
Instrumentation and control equipment
DN
Instrumentation and control equipment
DP
Instrumentation and control equipment
DQ
Instrumentation and control equipment
DR
Instrumentation and control equipment
DS
Instrumentation and control equipment
DT
Instrumentation and control equipment
DU
Instrumentation and control equipment
DV
Instrumentation and control equipment
DW
Instrumentation and control equipment
DX
Instrumentation and control equipment
DY
Instrumentation and control equipment
DZ
Instrumentation and control equipment
Printout date 14. Mrz. 01
Page D1 of D1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : E
04.04.97
E
Conventional fuel supply and residues disposal
EA
Unloading and storage of solid fuels
EB
Mechanical treatment of solid fuels (also for gas generation and treatment)
(crushing, mixing, drying etc.)
EC
Distribution of solid fuels
Limit: from incl. receiving point
to excl.
discharge into other systems
ED
Chemical treatment of solid fuels incl. residues removal (e. g. desulfurization
plant)
EE
Conversion of solid fuels (gas generation and treatment see function key *R*)
EG
Supply of liquid fuels
EH
Chemical treatment of liquid fuels incl. residues removal
EK
Supply of gaseous fuels
EL
Chemical treatment of gaseous fuels incl. residues removal
EM
Supply and treatment of fluxing agents
EN
Supply of other fuels (only for combinations of different fuel types)
EP
Treatment of other fuels (only for combinations of different fuel types)
EQ
Conversion of other fuels (only for combiations of different fuel types)
ER
Ignition fuel supply
ET
Ash and slag removal system (from excl. removal equipment)
EU
Treatment and transport system for combustion, fuel treatment, fuel conversion,
flue gas cleaning, gas generation residues
EV
Lubricant supply system
EW
Sealing fluid supply system
EX
Fluid supply system for control and protection equipment
EY
Control and protection equipment
Printout date 14. Mrz. 01
Page E1 of E1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : EA
04.04.97
E
Conventional fuel supply and residues disposal
EA
Unloading and storage of solid fuels
EAA
Ship unloading system
Limit: from incl. unloading equipment
to excl.
transport or storage plant
EAB
Rail wagon and truck unloading bay
Limit: from incl. unloading equipment
to excl.
transport or storage plant
EAC
Transport system
Limit: from incl. receiving point
to excl.
storage incl. internal transport system
within unloading and storage plant
to excl.
stacker
EAD
Stacking system
Limit: from excl. transport system
to excl. storage plant
EAE
Bunker system, storage area (stockyard)
Limit: from excl. unloading equipment or transport system
to excl. transport or bucket wheel or reclaimer or stacking system
EAF
Bucket wheel system, reclaimer system
Limit: from excl. bunker system or stockyard
to excl. transport system
EAT
Weighing equipment
EAU
Sampling equipment
EAV
Lubricant supply system
EAX
Fluid supply system for control and protection equipment
EAY
Control and protection equipment
Printout date 14. Mrz. 01
Page EA1 of EA1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : EB
04.04.97
E
Conventional fuel supply and residues disposal
EB
Mechanical treatment of solid fuels (also for gas generation and treatment)
(crushing, mixing, drying etc.)
EBA
Transport system
Limit: from incl. receiving point
to excl.
discharge into treatment or mixing system
EBB
Mixing system
Limit: from incl. receiving point
to excl.
discharge into other system
EBC
Crushing system, pulverizing system
Limit: from incl. receiving point
to excl.
discharge into other system
EBD
Screening system
Limit: from incl. receiving point
to excl.
discharge into other system
EBE
Separator system and discharge equipment thereof
Hint: unless not structural part of one of the former systems
(*EBA* to *EBD)
Limit: from incl. receiving point
to excl.
discharge into other system
EBF
Temporary storage system for milled raw coal
Limit: from incl. receiving point
to excl.
discharge into other system
EBG
Predrying system
Limit: from incl. receiving point
to excl.
discharge into other system
EBH
Main drying system
Limit: from incl. receiving point
to excl.
discharge into other system
EBJ
Dried coal transport system incl. aftercooling
Limit: from incl. receiving point
to excl.
discharge into other system
EBK
Dried coal temporary storage system
Limit: from incl. receiving point
to excl.
discharge into other system
EBL
Vapor compressor system
Limit: from incl. receiving point
to excl.
discharge into other system
EBM
Exhaust system
Limit: from incl. receiving point
to excl.
discharge into other system
EBR
Residues removal system
EBT
Weighing equipment
EBU
Sampling equipment
EBV
Lubricant supply system
Printout date 14. Mrz. 01
Page EB1 of EB2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : EB
04.04.97
EBX
Fluid supply system for control and protection equipment
EBY
Control and protection equipment
Printout date 14. Mrz. 01
Page EB2 of EB2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : EC
04.04.97
E
Conventional fuel supply and residues disposal
EC
Distribution of solid fuels
Limit: from incl. receiving point
to excl.
discharge into other systems
ECA
Distribution of solid fuels
ECB
Distribution of solid fuels
ECC
Distribution of solid fuels
ECD
Distribution of solid fuels
ECE
Distribution of solid fuels
ECF
Distribution of solid fuels
ECG
Distribution of solid fuels
ECH
Distribution of solid fuels
ECJ
Distribution of solid fuels
ECK
Distribution of solid fuels
ECL
Distribution of solid fuels
ECM
Distribution of solid fuels
ECN
Distribution of solid fuels
ECP
Distribution of solid fuels
ECQ
Distribution of solid fuels
ECR
Distribution of solid fuels
ECS
Distribution of solid fuels
ECT
Weighing equipment
ECU
Sampling equipment
ECX
Fluid supply system for control and protection equipment
ECY
Control and protection equipment
Printout date 14. Mrz. 01
Page EC1 of EC1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : ED
04.04.97
E
Conventional fuel supply and residues disposal
ED
Chemical treatment of solid fuels incl. residues removal (e. g. desulfurization
plant)
EDA
Chemical treatment of solid fuels incl. residues removal
EDB
Chemical treatment of solid fuels incl. residues removal
EDC
Chemical treatment of solid fuels incl. residues removal
EDD
Chemical treatment of solid fuels incl. residues removal
EDE
Chemical treatment of solid fuels incl. residues removal
EDF
Chemical treatment of solid fuels incl. residues removal
EDG
Chemical treatment of solid fuels incl. residues removal
EDH
Chemical treatment of solid fuels incl. residues removal
EDJ
Chemical treatment of solid fuels incl. residues removal
EDK
Chemical treatment of solid fuels incl. residues removal
EDL
Chemical treatment of solid fuels incl. residues removal
EDM
Chemical treatment of solid fuels incl. residues removal
EDN
Chemical treatment of solid fuels incl. residues removal
EDP
Chemical treatment of solid fuels incl. residues removal
EDQ
Chemical treatment of solid fuels incl. residues removal
EDR
Chemical treatment of solid fuels incl. residues removal
EDS
Chemical treatment of solid fuels incl. residues removal
EDT
Chemical treatment of solid fuels incl. residues removal
EDU
Chemical treatment of solid fuels incl. residues removal
EDV
Lubricant supply system
EDX
Fluid supply system for control and protection equipment
EDY
Control and protection equipment
Printout date 14. Mrz. 01
Page ED1 of ED1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : EE
04.04.97
E
Conventional fuel supply and residues disposal
EE
Conversion of solid fuels (gas generation and treatment see function key *R*)
EEA
Conversion of solid fuels
EEB
Conversion of solid fuels
EEC
Conversion of solid fuels
EED
Conversion of solid fuels
EEE
Conversion of solid fuels
EEF
Conversion of solid fuels
EEG
Conversion of solid fuels
EEH
Conversion of solid fuels
EEJ
Conversion of solid fuels
EEK
Conversion of solid fuels
EEL
Conversion of solid fuels
EEM
Conversion of solid fuels
EEN
Conversion of solid fuels
EEP
Conversion of solid fuels
EEQ
Conversion of solid fuels
EER
Conversion of solid fuels
EES
Conversion of solid fuels
EET
Conversion of solid fuels
EEU
Conversion of solid fuels
EEV
Lubricant supply system
EEX
Fluid supply system for control and protection equipment
EEY
Control and protection equipment
Printout date 14. Mrz. 01
Page EE1 of EE1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : EG
04.04.97
E
Conventional fuel supply and residues disposal
EG
Supply of liquid fuels
EGA
Receiving equipment incl. pipeline
Limit: from excl. receiving point
to excl.
tank, incl. pump
EGB
Tank farm
Limit: from incl. tank inlet
to incl.
tank outlet
EGC
Pump system
Limit: from incl. pump system suction nozzle
to incl.
pump system discharge nozzle
EGD
Piping system
Limit: from excl. tank outlet
to excl.
temporary storage system or branch to user
EGR
Residues removal system
EGT
Heating medium system
Limit: from excl. branch off supply system
to excl.
user and
from excl. user
to excl.
inlet to other system
EGV
Lubricant supply system
EGX
Fluid supply system for control and protection equipment
EGY
Control and protection equipment
Printout date 14. Mrz. 01
Page EG1 of EG1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : EH
04.04.97
E
Conventional fuel supply and residues disposal
EH
Chemical treatment of liquid fuels incl. residues removal
EHA
Chemical treatment of liquid fuels
EHB
Chemical treatment of liquid fuels
EHC
Additive dosing system
EHD
Chemical treatment of liquid fuels
EHE
Chemical treatment of liquid fuels
EHF
Chemical treatment of liquid fuels
EHG
Chemical treatment of light fuel oil
EHH
Chemical treatment of liquid fuels
EHJ
Chemical treatment of liquid fuels
EHK
Chemical treatment of liquid fuels
EHL
Chemical treatment of liquid fuels
EHM
Chemical treatment of liquid fuels
EHN
Chemical treatment of heavy fuel oil
EHP
Chemical treatment of liquid fuels
EHQ
Chemical treatment of liquid fuels
EHR
Chemical treatment of liquid fuels
EHS
Chemical treatment of liquid fuels
EHT
Heating medium system
Limit: from excl. branch off supply system
to excl. user and
from excl. user
to excl. inlet to other system
EHU
Chemical treatment of liquid fuels
EHV
Lubricant supply system
EHX
Fluid supply system for control and protection equipment
EHY
Control and protection equipment
Printout date 14. Mrz. 01
Page EH1 of EH1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : EK
04.04.97
E
Conventional fuel supply and residues disposal
EK
Supply of gaseous fuels
EKA
Receiving equipment incl. pipeline
Limit: from excl. receiving point
to incl. inlet to other system
EKB
Moisture separation system
Limit: from incl. moisture separator inlet
to incl.
moisture separator outlet
EKC
Heating system
Limit: from incl. heater inlet
to incl.
heater outlet
EKD
Main reducing station, expansion turbine
Limit: from incl. main reducing station inlet, expansion turbine inlet
to incl.
main reducing station outlet, expansion turbine outlet
EKE
Mechanical cleaning, scrubbing
Limit: from incl. inlet of mechanical cleaning, scrubbing system
to incl.
outlet mechanical cleaning, scrubbing system
EKF
Storage system
Limit: from incl. storage system inlet
to incl.
storage system outlet
EKG
Piping system
Limit: from excl. receiving point
to excl. branch to user
EKH
Main pressure boosting system
Limit: from incl. pump system suction nozzle
to incl.
pump system discharge nozzle
EKR
Residues removal system
EKT
Heating medium system
Limit: from excl. branch off supply system
to excl. user and
from excl. user
to excl. inlet to other system
EKV
Lubricant supply system
EKW
Sealing fluid supply system
EKX
Fluid supply system for control and protection equipment
EKY
Control and protection equipment
Printout date 14. Mrz. 01
Page EK1 of EK1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : EL
04.04.97
E
Conventional fuel supply and residues disposal
EL
Chemical treatment of gaseous fuels incl. residues removal
ELA
Chemical treatment of gaseous fuels incl. residues removal
ELB
Chemical treatment of gaseous fuels incl. residues removal
ELC
Chemical treatment of gaseous fuels incl. residues removal
ELD
Chemical treatment of gaseous fuels incl. residues removal
ELE
Chemical treatment of gaseous fuels incl. residues removal
ELF
Chemical treatment of gaseous fuels incl. residues removal
ELG
Chemical treatment of gaseous fuels incl. residues removal
ELH
Chemical treatment of gaseous fuels incl. residues removal
ELJ
Chemical treatment of gaseous fuels incl. residues removal
ELK
Chemical treatment of gaseous fuels incl. residues removal
ELL
Chemical treatment of gaseous fuels incl. residues removal
ELM
Chemical treatment of gaseous fuels incl. residues removal
ELN
Chemical treatment of gaseous fuels incl. residues removal
ELP
Chemical treatment of gaseous fuels incl. residues removal
ELQ
Chemical treatment of gaseous fuels incl. residues removal
ELR
Chemical treatment of gaseous fuels incl. residues removal
ELS
Chemical treatment of gaseous fuels incl. residues removal
ELT
Chemical treatment of gaseous fuels incl. residues removal
ELU
Chemical treatment of gaseous fuels incl. residues removal
ELV
Lubricant supply system
ELW
Sealing fluid supply system
ELX
Fluid supply system for control and protection equipment
ELY
Control and protection equipment
Printout date 14. Mrz. 01
Page EL1 of EL1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : EM
04.04.97
E
Conventional fuel supply and residues disposal
EM
Supply and treatment of fluxing agents
EMA
Supply and treatment of fluxing agents
EMB
Supply and treatment of fluxing agents
EMC
Supply and treatment of fluxing agents
EMD
Supply and treatment of fluxing agents
EME
Supply and treatment of fluxing agents
EMF
Supply and treatment of fluxing agents
EMG
Supply and treatment of fluxing agents
EMH
Supply and treatment of fluxing agents
EMJ
Supply and treatment of fluxing agents
EMK
Supply and treatment of fluxing agents
EML
Supply and treatment of fluxing agents
EMM
Supply and treatment of fluxing agents
EMN
Supply and treatment of fluxing agents
EMP
Supply and treatment of fluxing agents
EMQ
Supply and treatment of fluxing agents
EMR
Supply and treatment of fluxing agents
EMS
Supply and treatment of fluxing agents
EMT
Supply and treatment of fluxing agents
EMU
Supply and treatment of fluxing agents
EMV
Lubricant supply system
EMX
Fluid supply system for control and protection equipment
EMY
Control and protection equipment
Printout date 14. Mrz. 01
Page EM1 of EM1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : EN
04.04.97
E
Conventional fuel supply and residues disposal
EN
Supply of other fuels (only for combinations of different fuel types)
ENA
Receiving equipment incl. pipeline
Limit: from excl. receiving point
to excl. tank, incl. pump
ENB
Tank farm
Limit: from incl. tank inlet
to incl.
tank outlet
ENC
Pump system
Limit: from incl. pump system suction nozzle
to incl.
pump system discharge nozzle
END
Piping system
Limit: from excl. tank outlet
to excl. temporary storage system or branch to user
ENR
Residues removal system
ENT
Heating medium system
Limit: from excl. branch off supply system
to excl. user and
from excl. user
to excl. inlet to other system
ENV
Lubricant supply system
ENX
Fluid supply system for control and protection equipment
ENY
Control and protection equipment
Printout date 14. Mrz. 01
Page EN1 of EN1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : EP
04.04.97
E
Conventional fuel supply and residues disposal
EP
Treatment of other fuels (only for combinations of different fuel types)
EPC
Pump system
Limit: from incl. pump system suction nozzle
to incl.
pump system discharge nozzle
EPG
Physical treatment of light fuel oil
EPN
Physical treatment of heavy fuel oil
EPT
Heating medium system
Limit: from excl. branch off supply system
to excl. user and
from excl. user
to excl. inlet to other system
EPV
Lubricant supply system
EPX
Fluid supply system for control and protection equipment
EPY
Control and protection equipment
Printout date 14. Mrz. 01
Page EP1 of EP1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : EQ
04.04.97
E
Conventional fuel supply and residues disposal
EQ
Conversion of other fuels (only for combiations of different fuel types)
EQA
Conversion of other fuels
EQB
Conversion of other fuels
EQC
Conversion of other fuels
EQD
Conversion of other fuels
EQE
Conversion of other fuels
EQF
Conversion of other fuels
EQG
Conversion of other fuels
EQH
Conversion of other fuels
EQJ
Conversion of other fuels
EQK
Conversion of other fuels
EQL
Conversion of other fuels
EQM
Conversion of other fuels
EQN
Conversion of other fuels
EQP
Conversion of other fuels
EQQ
Conversion of other fuels
EQR
Conversion of other fuels
EQS
Conversion of other fuels
EQT
Conversion of other fuels
EQU
Conversion of other fuels
EQV
Lubricant supply system
EQX
Fluid supply system for control and protection equipment
EQY
Control and protection equipment
Printout date 14. Mrz. 01
Page EQ1 of EQ1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : ER
04.04.97
E
Conventional fuel supply and residues disposal
ER
Ignition fuel supply
ERA
Pulverized coal supply system
Limit: from excl. receiving point
to excl. branch to boiler or
to excl. other users
ERB
Oil supply system
Limit: from excl. receiving point
to excl. branch to boiler or
to excl. other users
ERC
Gas supply system
Limit: from excl. receiving point
to excl. branch to boiler or
to excl. other users
ERV
Lubricant supply system
ERX
Fluid supply system for control and protection equipment
ERY
Control and protection equipment
Printout date 14. Mrz. 01
Page ER1 of ER1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : ET
04.04.97
E
Conventional fuel supply and residues disposal
ET
Ash and slag removal system (from excl. removal equipment)
ETA
Wet ash conveying system
Limit: from excl. removal equipment or
from excl. receiving point
to excl. storage facility or
to excl. discharge into other system
ETB
Storage or settling pond for wet ash
Limit: from excl. receiving point
to incl. removal equipment
ETC
Wet ash dredger
Limit: from excl. receiving point
to excl. discharge into other system
ETD
Conveying system for granulate
Limit: from excl. removal equipment
to excl. storage facility or
to excl. discharge into other system
ETE
Storage system for granulate
Limit: from excl. receiving point
to incl. removal equipment
ETG
Conveying system for dry ash
Limit: from excl. removal equipment (boiler, electrostatic precipitator)
to excl. storage facilities or
to excl. discharge into other system
ETH
Storage system for dry ash
Limit: from excl. receiving point
to incl. removal equipment
ETK
Common conveying system for wet and dry ash
Limit: from excl. receiving point
to excl. storage facility or
to excl. discharge into other system
ETL
Common storage system for wet and dry ash
Limit: from excl. receiving point
to incl. removal equipment
ETM
Settling plant for wet and dry ash
Limit: from excl. receiving point from conveying system
to excl. pit or
to excl. discharge into other system
ETN
Forwarding, distribution, recovery and disposal systems for flushing and ash water
Limit: from excl. inlet or
from incl. branch
to excl. inlet to other system
ETP
Generation and distribution systems for carrier air
Limit: from excl. branch or
from incl. compressor system
to excl. inlet to conveying system
ETV
Lubricant supply system
ETX
Fluid supply system for control and protection equipment
Printout date 14. Mrz. 01
Page ET1 of ET2
Siemens
2 nd complete, non-project related edition
Condition-Date:
ETY
KKS
Identification System for Power
Plants
Function key : ET
04.04.97
Control and protection equipment
Printout date 14. Mrz. 01
Page ET2 of ET2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : EU
04.04.97
E
Conventional fuel supply and residues disposal
EU
Treatment and transport system for combustion, fuel treatment, fuel conversion,
flue gas cleaning, gas generation residues
EUA
Treatment system for fuel treatment residues
Limit: from incl. inlet
to incl.
outlet
EUB
Treatment system for fuel conversion residues
Limit: from incl. inlet
to incl.
outlet
EUC
Treatment system for fuel combustion residues
Limit: from incl. inlet
to incl.
outlet
EUD
Treatment system for flue gas cleaning residues
Limit: from incl. inlet
to incl.
outlet
EUE
Treatment system for gas generation and treatment residues
Limit: from incl. inlet
to incl.
outlet
EUF
Treatment system for fuel treatment residues
Hint: only if *EUA* is not sufficient for identification
Limit: from incl. inlet
to incl.
outlet
EUG
Treatment system for fuel treatment residues
Hint: only if *EUA* and *EUF* are not sufficient for identification
Limit: from incl. inlet
to incl.
outlet
EUH
Treatment system for fuel conversion residues
Hint: only if *EUB* is not sufficient for identification
Limit: from incl. inlet
to incl.
outlet
EUJ
Treatment system for fuel conversion residues
Hint: only if *EUB* and *EUH* are not sufficient for identification
Limit: from incl. inlet
to incl.
outlet
EUK
Treatment system for fuel combustion residues
Hint: only if *EUC* is not sufficient for identification
Limit: from incl. inlet
to incl.
outlet
EUL
Treatment system for fuel combustion residues
Hint: only if *EUC* and *EUK* are not sufficient for identification
Limit: from incl. inlet
to incl.
outlet
EUM
Treatment system for flue gas cleaning residues
Hint: only if *EUD* is not sufficient for identification
Limit: from incl. inlet
to incl.
outlet
Printout date 14. Mrz. 01
Page EU1 of EU2
Siemens
2 nd complete, non-project related edition
Condition-Date:
EUN
KKS
Identification System for Power
Plants
Function key : EU
04.04.97
Treatment system for flue gas cleaning residues
Hint: only if *EUD* and *EUM* are not sufficient for identification
Limit: from incl. inlet
to incl.
outlet
EUP
Treatment system for gas generation and treatment residues
Hint: only if *EUE* is not sufficient for identification
Limit: from incl. inlet
to incl.
outlet
EUQ
Treatment system for gas generation and treatment residues
Hint: only if *EUE* and *EUP* are not sufficient for identification
Limit: from incl. inlet
to incl.
outlet
EUV
Lubricant supply system
EUX
Fluid supply system for control and protection equipment
EUY
Control and protection equipment
Printout date 14. Mrz. 01
Page EU2 of EU2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : EV
04.04.97
E
Conventional fuel supply and residues disposal
EV
Lubricant supply system
EVA
Lubricant supply system
EVB
Lubricant supply system
EVC
Lubricant supply system
EVD
Lubricant supply system
EVE
Lubricant supply system
EVF
Lubricant supply system
EVG
Lubricant supply system
EVH
Lubricant supply system
EVJ
Lubricant supply system
EVK
Lubricant supply system
EVL
Lubricant supply system
EVM
Lubricant supply system
EVN
Lubricant supply system
EVP
Lubricant supply system
EVQ
Lubricant supply system
EVR
Lubricant supply system
EVS
Lubricant supply system
EVT
Lubricant supply system
EVU
Lubricant supply system
Printout date 14. Mrz. 01
Page EV1 of EV1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : EW
04.04.97
E
Conventional fuel supply and residues disposal
EW
Sealing fluid supply system
EWA
Sealing fluid supply system
EWB
Sealing fluid supply system
EWC
Sealing fluid supply system
EWD
Sealing fluid supply system
EWE
Sealing fluid supply system
EWF
Sealing fluid supply system
EWG
Sealing fluid supply system
EWH
Sealing fluid supply system
EWJ
Sealing fluid supply system
EWK
Sealing fluid supply system
EWL
Sealing fluid supply system
EWM
Sealing fluid supply system
EWN
Sealing fluid supply system
EWP
Sealing fluid supply system
EWQ
Sealing fluid supply system
EWR
Sealing fluid supply system
EWS
Sealing fluid supply system
EWT
Sealing fluid supply system
EWU
Sealing fluid supply system
Printout date 14. Mrz. 01
Page EW1 of EW1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : EX
04.04.97
E
Conventional fuel supply and residues disposal
EX
Fluid supply system for control and protection equipment
EXA
Fluid supply system for control and protection equipment
EXB
Fluid supply system for control and protection equipment
EXC
Fluid supply system for control and protection equipment
EXD
Fluid supply system for control and protection equipment
EXE
Fluid supply system for control and protection equipment
EXF
Fluid supply system for control and protection equipment
EXG
Fluid supply system for control and protection equipment
EXH
Fluid supply system for control and protection equipment
EXJ
Fluid supply system for control and protection equipment
EXK
Fluid supply system for control and protection equipment
EXL
Fluid supply system for control and protection equipment
EXM
Fluid supply system for control and protection equipment
EXN
Fluid supply system for control and protection equipment
EXP
Fluid supply system for control and protection equipment
EXQ
Fluid supply system for control and protection equipment
EXR
Fluid supply system for control and protection equipment
EXS
Fluid supply system for control and protection equipment
EXT
Fluid supply system for control and protection equipment
EXU
Fluid supply system for control and protection equipment
Printout date 14. Mrz. 01
Page EX1 of EX1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : EY
04.04.97
E
Conventional fuel supply and residues disposal
EY
Control and protection equipment
EYA
Control and protection equipment
EYB
Control and protection equipment
EYC
Control and protection equipment
EYD
Control and protection equipment
EYE
Control and protection equipment
EYF
Control and protection equipment
EYG
Control and protection equipment
EYH
Control and protection equipment
EYJ
Control and protection equipment
EYK
Control and protection equipment
EYL
Control and protection equipment
EYM
Control and protection equipment
EYN
Control and protection equipment
EYP
Control and protection equipment
EYQ
Control and protection equipment
EYR
Control and protection equipment
EYS
Control and protection equipment
EYT
Control and protection equipment
EYU
Control and protection equipment
Printout date 14. Mrz. 01
Page EY1 of EY1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : F
04.04.97
F
Handling of nuclear equipment
FA
Storage of fuel assemblies (also includes breeder and reflector assemblies) and
other radioactive components
FB
Handling of fuel assemblies (also includes breeder and reflector assemblies) and
other reactor core internals
FC
Refueling and transport equipment for fuel assemblies (also includes breeder and
reflector assemblies) and other reactor core internals
FJ
Erection and in-service inspection equipment
FK
Decontamination equipment (excluding cleaning equipment for fuel assemblies
store *FAM* and fuel assemblies *FBC*)
FV
Lubricant supply system
FW
Sealing fluid supply system
FX
Fluid supply system for control and protection equipment
FY
Control and protection equipment
Printout date 14. Mrz. 01
Page F1 of F1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : FA
04.04.97
F
Handling of nuclear equipment
FA
Storage of fuel assemblies (also includes breeder and reflector assemblies) and
other radioactive components
FAA
New fuel assemblies store
Task: to accommodate fuel assemblies and other radioactive components,
associated tools for storage and, where applicable,
manipulation
Scope: lining and support structure, leakage monitoring equipment
and internals
FAB
Irradiated fuel assemblies store (fuel pool)
Task: to accommodate fuel assemblies and other radioactive components,
associated tools for storage and, where applicable,
manipulation
Scope: lining and support structure, leakage monitoring equipment
and internals
FAC
Irradiated breeder assemblies store (not internal store)
Task: to accommodate breeder assemblies and the associated tools
for storage and, where applicable, manipulation
Scope: lining and support structure, leakage monitoring equipment
and internals
FAD
Additional fuel assemblies store
FAE
Reactor well equipment
Scope: lining and support structure, leakage monitoring equipment
and internals
FAF
Setdown area equipment
Task: temporary storage of reactor internals
Scope: lining and support structure, leakage monitoring equipment
and internals
FAH
Reusable activated components store
FAK
Fuel assemblies store cooling system (also fuel pool cooling system)
Task: to remove heat from the fuel assemblies store
FAL
Fuel assemblies store coolant cleaning system (also fuel pool cleaning system)
Task: to remove contaminants from the fuel assemblies store
coolant
FAM
Fuel assemblies store cleaning system
Task: to remove contaminants from the fuel assemblies store
FAN
Emergency fuel assemblies store cooling system
Task: to remove heat from the fuel assemblies store in emergencies
FAR
Dedicated blanket gas system for fuel assemblies store
Task: to protect fuel assemblies against oxidation
FAT
Heating, cooling, flushing distribution system (also evacuation)
FAV
Lubricant supply system
FAW
Sealing fluid supply system
FAX
Fluid supply system for control and protection equipment
FAY
Control and protection equipment
Printout date 14. Mrz. 01
Page FA1 of FA1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : FB
04.04.97
F
Handling of nuclear equipment
FB
Handling of fuel assemblies (also includes breeder and reflector assemblies) and
other reactor core internals
FBA
Fuel assemblies and other reactor core internals testing equipment
Task: to establish the condition of reactor core internals
FBB
Fuel assemblies and other reactor core internals repair equipment
Task: to repair reactor core internals
FBC
Fuel assemblies and other reactor core internals cleaning equipment
Task: to clean reactor core internals (for decontamination equipment see *FK*)
FBD
Size reduction equipment for fuel assemblies and other reactor core internals,
excl. components classified under *J..*
FBT
Heating, cooling, flushing distribution system (also evacuation)
FBV
Lubricant supply system
FBW
Sealing fluid supply system
FBX
Fluid supply system for control and protection equipment
FBY
Control and protection equipment
Printout date 14. Mrz. 01
Page FB1 of FB1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : FC
04.04.97
F
Handling of nuclear equipment
FC
Refueling and transport equipment for fuel assemblies (also includes breeder and
reflector assemblies) and other reactor core internals
FCA
Charge and discharge equipment
Task: to insert fuel absorber assemblies and similar components
into and to remove same from the reactor core with the aid
of a carrier fluid
FCB
Refueling equipment at reactor
Task: to exchange and reshuffle fuel assemblies and other reactor
core internals
FCC
Reshuffling equipment for reactor core internals
Hint: only if separate from *FCA* and *FCB*
Task: to reshuffle fuel assemblies and other reactor core internals
FCD
Refueling equipment in store for fuel assemblies and other reactor core internals
Task: to manipulate fuel assemblies and other reactor core
internals within the store
FCF
Fuel transfer equipment
Task: to enable transfer between compartments subject to different
operating conditions, only for fuel assemblies and other
reactor core internals
FCJ
Transport equipment
Task: to transfer fuel assemblies and other reactor core internals
between different stores
Scope: equipment for the transport of fuel assemblies and other
reactor core internals between different stores
FCL
Pressurizing and cooling system for fuel assemblies transport equipment
FCT
Heating, cooling, flushing distribution system (also evacuation)
FCV
Lubricant supply system
FCW
Sealing fluid supply system
FCX
Fluid supply system for control and protection equipment
FCY
Control and protection equipment
Printout date 14. Mrz. 01
Page FC1 of FC1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : FJ
04.04.97
F
Handling of nuclear equipment
FJ
Erection and in-service inspection equipment
FJA
Tools and erection equipment for the reactor pressure vessel and closure head
FJB
Tools and erection equipment for reactor pressure vessel internals
FJC
In-service inspection equipment for the reactor pressure vessel and closure head
FJE
Tools and erection equipment for reactor coolant system components
FJF
In-service inspection equipment for reactor coolant system components
FJM
Equipment for reactor containment
FJN
Handling equipment for sodium-wetted parts
FJP
Washing and decontamination equipment
FJQ
Hot cell equipment
Printout date 14. Mrz. 01
Page FJ1 of FJ1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : FK
04.04.97
F
Handling of nuclear equipment
FK
Decontamination equipment (excluding cleaning equipment for fuel assemblies
store *FAM* and fuel assemblies *FBC*)
FKA
Decontamination equipment for primary system components
FKB
Decontamination equipment for spent fuel shipping cask
FKE
Decontamination equipment for apparatus and vessels
FKJ
Decontamination equipment for fabrics
FKK
Decontamination equipment for machine components
FKN
Mobile decontamination equipment
FKT
Heating, cooling, flushing distribution system (also evacuation)
FKV
Lubricant supply system
FKW
Sealing fluid supply system
FKX
Fluid supply system for control and protection equipment
FKY
Control and protection equipment
Printout date 14. Mrz. 01
Page FK1 of FK1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : FV
04.04.97
F
Handling of nuclear equipment
FV
Lubricant supply system
FVA
Lubricant supply system
FVB
Lubricant supply system
FVC
Lubricant supply system
FVD
Lubricant supply system
FVE
Lubricant supply system
FVF
Lubricant supply system
FVG
Lubricant supply system
FVH
Lubricant supply system
FVJ
Lubricant supply system
FVK
Lubricant supply system
FVL
Lubricant supply system
FVM
Lubricant supply system
FVN
Lubricant supply system
FVP
Lubricant supply system
FVQ
Lubricant supply system
FVR
Lubricant supply system
FVS
Lubricant supply system
FVT
Lubricant supply system
FVU
Lubricant supply system
Printout date 14. Mrz. 01
Page FV1 of FV1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : FW
04.04.97
F
Handling of nuclear equipment
FW
Sealing fluid supply system
FWA
Sealing fluid supply system
FWB
Sealing fluid supply system
FWC
Sealing fluid supply system
FWD
Sealing fluid supply system
FWE
Sealing fluid supply system
FWF
Sealing fluid supply system
FWG
Sealing fluid supply system
FWH
Sealing fluid supply system
FWJ
Sealing fluid supply system
FWK
Sealing fluid supply system
FWL
Sealing fluid supply system
FWM
Sealing fluid supply system
FWN
Sealing fluid supply system
FWP
Sealing fluid supply system
FWQ
Sealing fluid supply system
FWR
Sealing fluid supply system
FWS
Sealing fluid supply system
FWT
Sealing fluid supply system
FWU
Sealing fluid supply system
Printout date 14. Mrz. 01
Page FW1 of FW1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : FX
04.04.97
F
Handling of nuclear equipment
FX
Fluid supply system for control and protection equipment
FXA
Fluid supply system for control and protection equipment
FXB
Fluid supply system for control and protection equipment
FXC
Fluid supply system for control and protection equipment
FXD
Fluid supply system for control and protection equipment
FXE
Fluid supply system for control and protection equipment
FXF
Fluid supply system for control and protection equipment
FXG
Fluid supply system for control and protection equipment
FXH
Fluid supply system for control and protection equipment
FXJ
Fluid supply system for control and protection equipment
FXK
Fluid supply system for control and protection equipment
FXL
Fluid supply system for control and protection equipment
FXM
Fluid supply system for control and protection equipment
FXN
Fluid supply system for control and protection equipment
FXP
Fluid supply system for control and protection equipment
FXQ
Fluid supply system for control and protection equipment
FXR
Fluid supply system for control and protection equipment
FXS
Fluid supply system for control and protection equipment
FXT
Fluid supply system for control and protection equipment
FXU
Fluid supply system for control and protection equipment
Printout date 14. Mrz. 01
Page FX1 of FX1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : FY
04.04.97
F
Handling of nuclear equipment
FY
Control and protection equipment
FYA
Control and protection equipment
FYB
Control and protection equipment
FYC
Control and protection equipment
FYD
Control and protection equipment
FYE
Control and protection equipment
FYF
Control and protection equipment
FYG
Control and protection equipment
FYH
Control and protection equipment
FYJ
Control and protection equipment
FYK
Control and protection equipment
FYL
Control and protection equipment
FYM
Control and protection equipment
FYN
Control and protection equipment
FYP
Control and protection equipment
FYQ
Control and protection equipment
FYR
Control and protection equipment
FYS
Control and protection equipment
FYT
Control and protection equipment
FYU
Control and protection equipment
Printout date 14. Mrz. 01
Page FY1 of FY1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : G
04.04.97
G
Water supply and disposal
GA
Raw water supply
GB
Treatment system (carbonate hardness removal) incl. cooling tower make-up
water treatment system
GC
Treatment system (demineralization)
GD
Treatment system (others), blowdown demineralizing system
GH
Distribution systems (not drinking water)
GK
Drinking water supply
GM
Plant drainage system
GN
Plant drains treatment system
GQ
Domestic waste water collection and drainage systems
GR
Domestic waste water treatment system
GT
Water recovery from waste water
GU
Rainwater collection and drainage systems incl. treatment system
GV
Lubricant supply system
GW
Sealing fluid supply system
GX
Fluid supply system for control and protection equipment
GY
Control and protection equipment
Printout date 14. Mrz. 01
Page G1 of G1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : GA
04.04.97
G
Water supply and disposal
GA
Raw water supply
GAA
Extraction, mechanical cleaning
Limit: from incl. intake
to incl.
mechanical cleaning system outlet
GAC
Piping and channel system
Limit: from excl. intake or
from excl. outlet of other system
to excl. inlet to other system
GAD
Storage system
Limit: from incl. storage system inlet
to incl.
storage system outlet, incl. intake and outfall
GAF
Pump system
Limit: from incl. pump system suction nozzle
to incl.
pump system discharge nozzle
GAV
Lubricant supply system
GAX
Fluid supply system for control and protection equipment
GAY
Control and protection equipment
Printout date 14. Mrz. 01
Page GA1 of GA1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : GB
04.04.97
G
Water supply and disposal
GB
Treatment system (carbonate hardness removal) incl. cooling tower make-up
water treatment system
GBB
Filtering, mechanical cleaning system
Limit: from incl. separation equipment inlet
to incl.
separation equipment outlet
GBC
Aeration, gas injection system
Limit: from excl. atmosphere or
from incl. gas supply
GBD
Precipitation system (e. g. for carbonate hardness removal)
Limit: from incl. precipitation equipment inlet
to incl.
precipitation equipment outlet
GBE
Acid proportioning system (e. g. for carbonate hardness removal)
Limit: from incl. acid proportioning equipment
from excl. branch off chemicals supply system
to excl.
inlet to other system
GBF
Ion exchange, reverse osmosis system (e. g. for carbonate hardness removal)
Limit: from incl. ion exchanger inlet or
from incl. isolating valve of chemicals supply system or auxiliary fluid supply
system upstream of ion exchanger
GBG
Evaporation system (e. g. for carbonate hardness removal)
Limit: from incl. feedwater inlet
to incl.
steam outlet and
from incl. heating steam inlet
to incl.
condensate outlet
GBH
Deaeration, drying system
Limit: from incl. deaerator or tank inlet
to incl.
tank outlet incl. warm-up equipment of vapour condenser
GBJ
Preheating, cooling system
Limit: from incl. preheater or cooler inlet
to incl.
preheater or cooler outlet
GBK
Piping system, temporary storage system, pump system for main fluid
Limit: Piping system:
from excl. intake or
from excl. outlet of other system
to excl. inlet to other system
to incl. fluid treatment system outlet
Temporary storage system:
from incl. temporary storage system inlet
to incl. temporary storage system outlet
Pump system:
from incl. pump system suction nozzle
to incl. pump system discharge nozzle
GBL
Storage system outside fluid treatment system (if not part of another system)
Limit: from incl. inlet storage system
to excl.
outlet storage system incl. intake and outfall
GBN
Chemicals supply system
Limit: from incl. intake or
from incl. storage tank
to excl.
discharge into other system
Printout date 14. Mrz. 01
Page GB1 of GB2
Siemens
2 nd complete, non-project related edition
Condition-Date:
GBP
KKS
Identification System for Power
Plants
Function key : GB
04.04.97
Regeneration, flushing equipment
Limit: from incl. system inlet
to excl.
inlet to other system
from excl. chemicals or auxiliary fluid supply system and
flushing air supply system
to incl.
regenerating, flushing equipment
GBQ
Injection system for main fluid (for hardness stablization)
Limit: from incl. injection equipment
from excl. branch off chemicals supply system
to excl.
inlet to other system
GBR
Flushing water and residues removal system incl. neutralization
Limit: from excl. outlet of respective system
to excl. discharge into disposal system
GBS
Sludge thickening system
Limit: from excl. outlet of respective system
to excl. discharge into other system
GBT
Heating, cooling and flushing fluid distribution system
Limit: from incl. heating, cooling, flushing fluid generation equipment or
from excl. branch off heating, cooling, flushing fluid supply system
to excl.
user and
from excl. user
GBV
Lubricant supply system
GBX
Fluid supply system for control and protection equipment
GBY
Control and protection equipment
Printout date 14. Mrz. 01
Page GB2 of GB2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : GC
04.04.97
G
Water supply and disposal
GC
Treatment system (demineralization)
GCB
Filtering, mechanical cleaning system
Limit: from incl. separation equipment inlet
to incl.
separation equipment outlet
GCC
Aeration, gas injection system
Limit: from excl. atmosphere or
from incl. gas supply
GCD
Precipitation system (e. g. for carbonate hardness removal)
Limit: from incl. precipitation equipment inlet
to incl.
precipitation equipment outlet
GCE
Acid proportioning system (e. g. for carbonate hardness removal)
Limit: from incl. acid proportioning equipment or
from excl. branch off chemicals supply system
to excl.
inlet to other system
GCF
Ion exchange, reverse osmosis system (e. g. for demineralization)
Limit: from incl. ion exchanger inlet
from incl. isolating valve of chemicals supply system or
auxiliary fluid supply system upstream of ion exchanger
GCG
Evaporation system (e. g. for demineralization)
Limit: from incl. feedwater inlet
to incl.
steam outlet and
from incl. heating steam inlet
to incl.
condensate outlet
GCH
Deaeration, drying system
Limit: from incl. deaerator or tank inlet
to incl.
tank outlet incl. warm-up equipment of vapour condenser
GCJ
Preheating, cooling system
Limit: from incl. preheater or cooler inlet
to incl.
preheater or cooler outlet
GCK
Piping system, temporary storage system, pump system for main fluid
Limit: Piping system:
from excl. intake or
from excl. outlet of other system
to excl. inlet to other system
to incl. fluid treatment system outlet
Temporary storage system:
from incl. temporary storage system inlet
to incl. temporary storage system outlet
Pump system:
from incl. pump system suction nozzle
to incl. pump system discharge nozzle
GCL
Storage system outside fluid treatment system (if not part of another system)
Limit: from incl. inlet storage system
to incl.
outlet storage system incl. intake and outfall
GCN
Chemicals supply system
Limit: from incl. intake or
from incl. storage tank
to excl.
discharge into other system
Printout date 14. Mrz. 01
Page GC1 of GC2
Siemens
2 nd complete, non-project related edition
Condition-Date:
GCP
KKS
Identification System for Power
Plants
Function key : GC
04.04.97
Regeneration, flushing equipment
Limit: from incl. system inlet
to excl.
inlet to other system
from excl. chemicals or auxiliary fluid supply system and
flushing air supply system
to incl.
regenerating, flushing equipment
GCQ
Injection system for main fluid
Limit: from incl. injection equipment or
from excl. branch off chemicals supply system
to excl.
inlet to other system
GCR
Flushing water and residues removal system incl. neutralization
Limit: from excl. outlet of respective system
to excl. discharge into disposal system
GCS
Sludge thickening system
Limit: from excl. outlet of respective system
to excl. discharge into other system
GCT
Heating, cooling and flushing fluid distribution system
Limit: from incl. heating, cooling and flushing fluid generation equipment or
from excl. branch off heating, cooling, flushing fluid supply system
to excl.
user and
from excl. user
GCV
Lubricant supply system
GCX
Fluid supply system for control and protection equipment
GCY
Control and protection equipment
Printout date 14. Mrz. 01
Page GC2 of GC2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : GD
04.04.97
G
Water supply and disposal
GD
Treatment system (others), blowdown demineralizing system
GDB
Filtering, mechanical cleaning system
Limit: from incl. separation equipment inlet
to incl.
separation equipment outlet
GDC
Aearation, gas injection system
Limit: from excl. atmosphere or
from incl. gas supply
GDD
Precipitation system (e. g. for carbonate hardness removal)
Limit: from incl. precipitation equipment inlet
to incl.
precipitation equipment outlet
GDE
Acid proportioning system (e. g. for carbonate hardness removal)
Limit: from incl. acid proportioning equipment or
from excl. branch off chemicals supply system
to excl.
inlet to other system
GDF
Ion exchange, reverse osmosis system (e. g. for demineralization)
Limit: from incl. ion exchanger inlet or
from incl. isolating valve of chemicals supply system or
auxiliary fluid supply system upstream of ion exchanger
GDG
Evaporation system (e. g. for demineralization)
Limit: from incl. feedwater inlet
to incl.
steam outlet and
from incl. heating steam inlet
to incl.
condensate outlet
GDH
Deaeration, drying system
Limit: from incl. deaerator or tank inlet
to incl.
tank outlet incl. warm-up equipment of vapour condenser
GDJ
Preheating, cooling system
Limit: from incl. preheater or cooler inlet
to incl.
preheater or cooler outlet
GDK
Piping system, temporary storage system, pump system for main fluid
Limit: Piping system:
from excl. intake or
from excl. outlet of other system
to excl. inlet to other system
to incl. fluid treatment system outlet
Temporary storage system:
from incl. temporary storage system inlet
to incl. temporary storage system outlet
Pump system:
from incl. pump system suction nozzle
to incl.
pump system discharge nozzle
GDL
Storage system outside fluid treatment system (if not part of another system)
Limit: from incl. inlet storage system
to incl.
outlet storage system incl. intake and outfall
GDN
Chemicals supply system
Limit: from incl. intake or
from incl. storage tank
to excl.
discharge into other system
Printout date 14. Mrz. 01
Page GD1 of GD2
Siemens
2 nd complete, non-project related edition
Condition-Date:
GDP
KKS
Identification System for Power
Plants
Function key : GD
04.04.97
Regeneration, flushing equipment
Limit: from incl. system inlet
to excl.
inlet to other system
from excl. chemicals or auxiliary fluid supply system and
flushing air supply system
to incl.
regenerating, flushing equipment
GDQ
Injection system for main fluid
Limit: from incl. injection equipment or
from excl. branch off chemicals supply system
to excl.
inlet to other system
GDR
Flushing water and residues removal system incl. neutralization
Limit: from excl. outlet of respective system
to excl. discharge into disposal system
GDS
Sludge thickening system
Limit: from excl. outlet of respective system
to excl. discharge into other system
GDT
Heating, cooling and flushing fluid distribution system
Limit: from incl. heating, cooling, flushing fluid generation equipment or
from excl. branch off heating, cooling, flushing fluid supply system
to excl.
user and
from excl. user
GDV
Lubricant supply system
GDX
Fluid supply system for control and protection equipment
GDY
Control and protection equipment
Printout date 14. Mrz. 01
Page GD2 of GD2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : GH
04.04.97
G
Water supply and disposal
GH
Distribution systems (not drinking water)
GHB
Distribution system after treatment (carbonate hardness removal)
Limit: to excl.
GHC
Distribution system after treatment (demineralization) (demineralized water
supply system)
Limit: to excl.
GHD
inlet to other system
inlet to other system
Distribution system after treatment (others) (stand-by water supply)
Limit: to excl.
inlet to other system
GHE
Distribution system (not drinking water)
GHF
Distribution system (not drinking water)
GHG
Distribution system (not drinking water)
GHH
Distribution system (not drinking water)
GHJ
Distribution system (not drinking water)
GHK
Distribution system (not drinking water)
GHL
Distribution system (not drinking water)
GHM
Distribution system (not drinking water)
GHN
Distribution system (not drinking water)
GHP
Distribution system (not drinking water)
GHQ
Distribution system (not drinking water)
GHR
Distribution system (not drinking water)
GHS
Distribution system (not drinking water)
GHT
Distribution system (not drinking water)
GHU
Distribution system (not drinking water)
GHX
Fluid supply system for control and protection equipment
GHY
Control and protection equipment
Printout date 14. Mrz. 01
Page GH1 of GH1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : GK
04.04.97
G
Water supply and disposal
GK
Drinking water supply
GKA
Receiving point
GKB
Storage, forwarding, distribution system
GKC
Drinking water supply (e. g. assigned to structures)
GKD
Drinking water supply (e. g. assigned to structures)
GKE
Drinking water supply (e. g. assigned to structures)
GKF
Drinking water supply (e. g. assigned to structures)
GKG
Drinking water supply (e. g. assigned to structures)
GKH
Drinking water supply (e. g. assigned to structures)
GKJ
Drinking water supply (e. g. assigned to structures)
GKK
Drinking water supply (e. g. assigned to structures)
GKL
Drinking water supply (e. g. assigned to structures)
GKM
Drinking water supply (e. g. assigned to structures)
GKN
Drinking water supply (e. g. assigned to structures)
GKP
Drinking water supply (e. g. assigned to structures)
GKQ
Drinking water supply (e. g. assigned to structures)
GKR
Drinking water supply (e. g. assigned to structures)
GKS
Drinking water supply (e. g. assigned to structures)
GKT
Drinking water supply (e. g. assigned to structures)
GKU
Drinking water supply (e. g. assigned to structures)
GKX
Fluid supply system for control and protection equipment
GKY
Control and protection equipment
Printout date 14. Mrz. 01
Page GK1 of GK1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : GM
04.04.97
G
Water supply and disposal
GM
Plant drainage system
GMA
Plant drainage system (e. g. assigned to structures)
GMB
Plant drainage system (e. g. assigned to structures)
GMC
Plant drainage system (e. g. assigned to structures)
GMD
Plant drainage system (e. g. assigned to structures)
GME
Plant drainage system (e. g. assigned to structures)
GMF
Plant drainage system (e. g. assigned to structures)
GMG
Plant drainage system (e. g. assigned to structures)
GMH
Plant drainage system (e. g. assigned to structures)
GMJ
Plant drainage system (e. g. assigned to structures)
GMK
Plant drainage system (e. g. assigned to structures)
GML
Plant drainage system (e. g. assigned to structures)
GMM
Plant drainage system (e. g. assigned to structures)
GMN
Plant drainage system (e. g. assigned to structures)
GMP
Plant drainage system (e. g. assigned to structures)
GMQ
Plant drainage system (e. g. assigned to structures)
GMR
Plant drainage system (e. g. assigned to structures)
GMS
Plant drainage system (e. g. assigned to structures)
GMT
Plant drainage system (e. g. assigned to structures)
GMU
Plant drainage system (e. g. assigned to structures)
GMX
Fluid supply system for control and protection equipment
GMY
Control and protection equipment
Printout date 14. Mrz. 01
Page GM1 of GM1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : GN
04.04.97
G
Water supply and disposal
GN
Plant drains treatment system
GNB
Filtering, mechanical cleaning system
Limit: from incl. separation equipment inlet
to incl.
separation equipment outlet
GNC
Aeration, gas injection system
Limit: from excl. atmosphere or
from incl. gas supply
GND
Precipitation system (e. g. for carbonate hardness removal)
Limit: from incl. precipitation equipment inlet
to incl.
precipitation equipment outlet
GNE
Acid proportioning system (e. g. for carbonate hardness removal)
Limit: from incl. acid proportioning equipment or
from excl. branch off chemicals supply system
to excl.
inlet to other system
GNF
Ion exchange system (e. g. for demineralization)
Limit: from incl. ion exchanger inlet
from incl. isolating valve of chemicals supply system or
auxiliary fluid supply system upstream of ion exchanger
GNG
Evaporation system (e. g. for demineralization)
Limit: from incl. feedwater inlet
to incl.
steam outlet and
from incl. heating steam inlet
to incl.
condensate outlet
GNH
Deaeration, drying system
Limit: from incl. deaerator or tank inlet
to incl.
tank outlet incl. warm-up equipment of
vapour condenser
GNJ
Preheating, cooling system
Limit: from incl. preheater or cooler inlet
to incl.
preheater or cooler outlet
GNK
Piping system, temporary storage system, pump system for main fluid
Limit: Piping system:
from excl. intake or
from excl. outlet of other system
to excl. inlet to other system
to incl. fluid treatment system outlet
Temporary storage system:
from incl. temporary storage system inlet
to incl. temporary storage system outlet
Pump system:
from incl. pump system suction nozzle
to incl. pump system discharge nozzle
GNL
Storage system outside fluid treatment system (if not part of another system)
Limit: from incl. inlet storage system
to incl.
outlet storage system incl. intake and outfall
GNN
Chemicals supply system
Limit: from incl. intake or
from incl. storage tank
to excl.
discharge into other system
Printout date 14. Mrz. 01
Page GN1 of GN2
Siemens
2 nd complete, non-project related edition
Condition-Date:
GNP
KKS
Identification System for Power
Plants
Function key : GN
04.04.97
Regeneration, flushing equipment
Limit: from incl. system inlet
to excl.
inlet to other system
from excl. chemicals or auxiliary fluid supply system and
flushing air supply system
to incl.
regenerating, flushing equipment
GNQ
Injection system for main fluid
Limit: from incl. injection equipment or
from excl. branch off chemicals supply system
to excl.
inlet to other system
GNR
Flushing water and residues removal system incl. neutralization
Limit: from excl. outlet of respective system
to excl. discharge into disposal system
GNS
Sludge thickening system
Limit: from excl. outlet of respective system
to excl. discharge into other system
GNT
Heating, cooling and flushing fluid distribution system
Limit: from incl. heating, cooling, flushing fluid generation equipment or
from excl. branch off heating, cooling, flushing fluid supply system
to excl.
user and
from excl. user
GNV
Lubricant supply system
GNX
Fluid supply system for control and protection equipment
GNY
Control and protection equipment
Printout date 14. Mrz. 01
Page GN2 of GN2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : GQ
04.04.97
G
Water supply and disposal
GQ
Domestic waste water collection and drainage systems
GQA
Domestic waste water collection and drainage system (e. g. assigned to
structures)
GQB
Domestic waste water collection and drainage system (e. g. assigned to
structures)
GQC
Domestic waste water collection and drainage system (e. g. assigned to
structures)
GQD
Domestic waste water collection and drainage system (e. g. assigned to
structures)
GQE
Domestic waste water collection and drainage system (e. g. assigned to
structures)
GQF
Domestic waste water collection and drainage system (e. g. assigned to
structures)
GQG
Domestic waste water collection and drainage system (e. g. assigned to
structures)
GQH
Domestic waste water collection and drainage system (e. g. assigned to
structures)
GQJ
Domestic waste water collection and drainage system (e. g. assigned to
structures)
GQK
Domestic waste water collection and drainage system (e. g. assigned to
structures)
GQL
Domestic waste water collection and drainage system (e. g. assigned to
structures)
GQM
Domestic waste water collection and drainage system (e. g. assigned to
structures)
GQN
Domestic waste water collection and drainage system (e. g. assigned to
structures)
GQP
Domestic waste water collection and drainage system (e. g. assigned to
structures)
GQQ
Domestic waste water collection and drainage system (e. g. assigned to
structures)
GQR
Domestic waste water collection and drainage system (e. g. assigned to
structures)
GQS
Domestic waste water collection and drainage system (e. g. assigned to
structures)
GQT
Domestic waste water collection and drainage system (e. g. assigned to
structures)
GQU
Domestic waste water collection and drainage system (e. g. assigned to
structures)
GQX
Fluid supply system for control and protection equipment
Printout date 14. Mrz. 01
Page GQ1 of GQ2
Siemens
2 nd complete, non-project related edition
Condition-Date:
GQY
KKS
Identification System for Power
Plants
Function key : GQ
04.04.97
Control and protection equipment
Printout date 14. Mrz. 01
Page GQ2 of GQ2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : GR
04.04.97
G
Water supply and disposal
GR
Domestic waste water treatment system
GRB
Filtering, mechanical cleaning system
Limit: from incl. separation equipment inlet
to incl.
separation equipment outlet
GRC
Aeration, gas injection system
Limit: from excl. atmosphere or
from incl. gas supply
GRD
Precipitation system (e. g. for carbonate hardness removal)
Limit: from incl. precipitation equipment inlet
to incl.
precipitation equipment outlet
GRE
Acid proportioning system (e. g. for carbonate hardness removal)
Limit: from incl. acid proportioning equipment or
from excl. branch off chemicals supply system
to excl.
inlet to other system
GRF
Ion exchange system (e. g. for demineralization)
Limit: from incl. ion exchanger inlet or
from incl. isolating valve of chemicals supply system or
auxiliary fluid supply system upstream of ion exchanger
GRG
Evaporation system (e. g. for demineralization)
Limit: from incl. feedwater inlet
to incl.
steam outlet and
from incl. heating steam inlet
to incl.
condensate outlet
GRH
Deaeration, drying system
Limit: from incl. deaerator or tank inlet
to incl.
tank outlet incl. warm-up equipment of vapour condenser
GRJ
Preheating, cooling system
Limit: from incl. preheater or cooler inlet
to incl.
preheater or cooler outlet
GRK
Piping system, temporary storage system, pump system for main fluid
Limit: Piping system:
from excl. intake or
from excl. outlet of other system
to excl. inlet to other system
to incl. fluid treatment system outlet
Temporary storage system:
from incl. temporary storage system inlet
to incl. temporary storage system outlet
Pump system:
from incl. pump system suction nozzle
to incl. pump system discharge nozzle
GRL
Storage system outside fluid treatment system (if not part of another system)
Limit: from incl. inlet storage system
to incl.
outlet storage system incl. intake and outfall
GRN
Chemicals supply system
Limit: from incl. intake or
from incl. storage tank
to excl.
discharge into other system
Printout date 14. Mrz. 01
Page GR1 of GR2
Siemens
2 nd complete, non-project related edition
Condition-Date:
GRP
KKS
Identification System for Power
Plants
Function key : GR
04.04.97
Regeneration,flushing equipment
Limit: from incl. system inlet
to excl.
inlet to other system
from excl. chemicals or auxiliary fluid supply system and
flushing air supply system
to incl.
regenerating, flushing equipment
GRQ
Injection system for main fluid
Limit: from incl. injection equipment or
from excl. branch off chemicals supply system
to excl.
inlet to other system
GRR
Flushing water and residues removal system incl. neutralization
Limit: from excl. outlet of respective system
to excl. discharge into disposal system
GRS
Sludge thickening system
Limit: from excl. outlet of respective system
to excl. discharge into other system
GRT
Heating, cooling and flushing fluid distribution system
Limit: from incl. heating, cooling, flushing fluid generation equipment or
from excl. branch off heating, cooling, flushing fluid supply system
to excl.
user and
from excl. user
GRV
Lubricant supply system
GRX
Fluid supply system for control and protection equipment
GRY
Control and protection equipment
Printout date 14. Mrz. 01
Page GR2 of GR2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : GT
04.04.97
G
Water supply and disposal
GT
Water recovery from waste water
GTA
Water recovery from waste water
GTB
Water recovery from waste water
GTC
Water recovery from waste water
GTD
Water recovery from waste water
GTE
Water recovery from waste water
GTF
Water recovery from waste water
GTG
Water recovery from waste water
GTH
Water recovery from waste water
GTJ
Water recovery from waste water
GTK
Water recovery from waste water
GTL
Water recovery from waste water
GTM
Water recovery from waste water
GTN
Water recovery from waste water
GTP
Water recovery from waste water
GTQ
Water recovery from waste water
GTR
Water recovery from waste water
GTS
Water recovery from waste water
GTT
Water recovery from waste water
GTU
Water recovery from waste water
GTX
Fluid supply system for control and protection equipment
GTY
Control and protection equipment
Printout date 14. Mrz. 01
Page GT1 of GT1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : GU
04.04.97
G
Water supply and disposal
GU
Rainwater collection and drainage systems incl. treatment system
GUA
Rainwater collection and drainage systems incl. treatment system
(e. g. assigned to structures)
GUB
Rainwater collection and drainage systems incl. treatment system
(e. g. assigned to structures)
GUC
Rainwater collection and drainage systems incl. treatment system
(e. g. assigned to structures)
GUD
Rainwater collection and drainage systems incl. treatment system
(e. g. assigned to structures)
GUE
Rainwater collection and drainage systems incl. treatment system
(e. g. assigned to structures)
GUF
Rainwater collection and drainage systems incl. treatment system
(e. g. assigned to structures)
GUG
Rainwater collection and drainage systems incl. treatment system
(e. g. assigned to structures)
GUH
Rainwater collection and drainage systems incl. treatment system
(e. g. assigned to structures)
GUJ
Rainwater collection and drainage systems incl. treatment system
(e. g. assigned to structures)
GUK
Rainwater collection and drainage systems incl. treatment system
(e. g. assigned to structures)
GUL
Rainwater collection and drainage systems incl. treatment system
(e. g. assigned to structures)
GUM
Rainwater collection and drainage systems incl. treatment system
(e. g. assigned to structures)
GUN
Rainwater collection and drainage systems incl. treatment system
(e. g. assigned to structures)
GUP
Rainwater collection and drainage systems incl. treatment system
(e. g. assigned to structures)
GUQ
Rainwater collection and drainage systems incl. treatment system
(e. g. assigned to structures)
GUR
Rainwater collection and drainage systems incl. treatment system
(e. g. assigned to structures)
GUS
Rainwater collection and drainage systems incl. treatment system
(e. g. assigned to structures)
GUT
Rainwater collection and drainage systems incl. treatment system
(e. g. assigned to structures)
GUU
Rainwater collection and drainage systems incl. treatment system
(e. g. assigned to structures)
GUX
Fluid supply system for control and protection equipment
Printout date 14. Mrz. 01
Page GU1 of GU2
Siemens
2 nd complete, non-project related edition
Condition-Date:
GUY
KKS
Identification System for Power
Plants
Function key : GU
04.04.97
Control and protection equipment
Printout date 14. Mrz. 01
Page GU2 of GU2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : GV
04.04.97
G
Water supply and disposal
GV
Lubricant supply system
GVA
Lubricant supply system
GVB
Lubricant supply system
GVC
Lubricant supply system
GVD
Lubricant supply system
GVE
Lubricant supply system
GVF
Lubricant supply system
GVG
Lubricant supply system
GVH
Lubricant supply system
GVJ
Lubricant supply system
GVK
Lubricant supply system
GVL
Lubricant supply system
GVM
Lubricant supply system
GVN
Lubricant supply system
GVP
Lubricant supply system
GVQ
Lubricant supply system
GVR
Lubricant supply system
GVS
Lubricant supply system
GVT
Lubricant supply system
GVU
Lubricant supply system
Printout date 14. Mrz. 01
Page GV1 of GV1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : GW
04.04.97
G
Water supply and disposal
GW
Sealing fluid supply system
GWA
Sealing fluid supply system
GWB
Sealing fluid supply system
GWC
Sealing fluid supply system
GWD
Sealing fluid supply system
GWE
Sealing fluid supply system
GWF
Sealing fluid supply system
GWG
Sealing fluid supply system
GWH
Sealing fluid supply system
GWJ
Sealing fluid supply system
GWK
Sealing fluid supply system
GWL
Sealing fluid supply system
GWM
Sealing fluid supply system
GWN
Sealing fluid supply system
GWP
Sealing fluid supply system
GWQ
Sealing fluid supply system
GWR
Sealing fluid supply system
GWS
Sealing fluid supply system
GWT
Sealing fluid supply system
GWU
Sealing fluid supply system
Printout date 14. Mrz. 01
Page GW1 of GW1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : GX
04.04.97
G
Water supply and disposal
GX
Fluid supply system for control and protection equipment
GXA
Fluid supply system for control and protection equipment
GXB
Fluid supply system for control and protection equipment
GXC
Fluid supply system for control and protection equipment
GXD
Fluid supply system for control and protection equipment
GXE
Fluid supply system for control and protection equipment
GXF
Fluid supply system for control and protection equipment
GXG
Fluid supply system for control and protection equipment
GXH
Fluid supply system for control and protection equipment
GXJ
Fluid supply system for control and protection equipment
GXK
Fluid supply system for control and protection equipment
GXL
Fluid supply system for control and protection equipment
GXM
Fluid supply system for control and protection equipment
GXN
Fluid supply system for control and protection equipment
GXP
Fluid supply system for control and protection equipment
GXQ
Fluid supply system for control and protection equipment
GXR
Fluid supply system for control and protection equipment
GXS
Fluid supply system for control and protection equipment
GXT
Fluid supply system for control and protection equipment
GXU
Fluid supply system for control and protection equipment
Printout date 14. Mrz. 01
Page GX1 of GX1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : GY
04.04.97
G
Water supply and disposal
GY
Control and protection equipment
GYA
Control and protection equipment
GYB
Control and protection equipment
GYC
Control and protection equipment
GYD
Control and protection equipment
GYE
Control and protection equipment
GYF
Control and protection equipment
GYG
Control and protection equipment
GYH
Control and protection equipment
GYJ
Control and protection equipment
GYK
Control and protection equipment
GYL
Control and protection equipment
GYM
Control and protection equipment
GYN
Control and protection equipment
GYP
Control and protection equipment
GYQ
Control and protection equipment
GYR
Control and protection equipment
GYS
Control and protection equipment
GYT
Control and protection equipment
GYU
Control and protection equipment
Printout date 14. Mrz. 01
Page GY1 of GY1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : H
04.04.97
H
Conventional heat generation
HA
Pressure system, feedwater and steam sections
HB
Support structure, enclosure, steam generator interior
HC
Fireside heat transfer surface cleaning equipment
HD
Ash and slag removal, particulate removal
HF
Bunker, feeder and pulverizing system
HH
Main firing system (electric-powered as well)
HJ
Ignition firing equipment (if separate)
HL
Combustion air system (primary air, secondary air)
HM
Gas heating system (for closed cycle)
HN
Flue gas exhaust (without flue gas treatment)
HR
Chemical flue gas treatment system incl. residues removal, adsorptive process
HS
Chemical flue gas treatment system incl. residues removal, catalytic process
(e. g. DENOX)
HT
Chemical flue gas treatment system incl. residues removal, absorptive process
(e. g. flue gas desulfurization plants)
HU
Flue gas reheating system
HV
Lubricant supply system
HW
Sealing fluid supply system
HX
Fluid supply system for control and protection equipment
HY
Control and protection equipment
Printout date 14. Mrz. 01
b
Page H1 of H1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : HA
04.04.97
H
Conventional heat generation
HA
Pressure system, feedwater and steam sections
HAA
LP part-flow feed heating system (flue-gas-heated)
Limit: from incl. LP part-flow feed heating system inlet
to incl.
LP part-flow feed heating system outlet
HAB
HP part-flow feed heating system (flue-gas-heated)
Limit: from incl. HP part-flow feed heating system inlet
to incl.
HP part-flow feed heating system outlet
HAC
Economizer system
Limit: from incl. oiler inlet header
to excl.
evaporator inlet incl. control and
auxiliary heat transfer surfaces
HAD
Evaporator system
a
Limit: from incl. evaporator system inlet
to incl.
evaporator system outlet and
to incl.
water/steam separator and water collecting vessel
HAG
Circulation system
a
Limit: from excl. water/steam separator and water collecting vessel
to excl. inlet to heat transfer surface system
(removal systems are classified under *L..*) or
to excl. feedwater system
HAH
HP superheater system
Limit: from excl. evaporator system outlet
to incl. boiler outlet header
HAJ
Reheat system
Limit: from incl. reheater inlet header
to incl.
reheater outlet header
HAK
Secondary reheat system
Limit: from incl. second reheater inlet header
to incl.
second reheater outlet header
HAM
Triflux system
Limit: from incl. triflux system inlet
to incl.
triflux system outlet
HAN
Pressure system drainage and venting systems
Limit: from incl. collecting point or
from excl. final drain/vent valve
to excl.
discharge into other system
HAV
Lubricant supply system
HAW
Sealing fluid supply system
HAX
Fluid supply system for control and protection equipment
HAY
Control and protection equipment
Printout date 14. Mrz. 01
Page HA1 of HA1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : HB
04.04.97
H
Conventional heat generation
HB
Support structure, enclosure, steam generator interior
HBA
Frame incl. foundations
HBB
Enclosures
HBC
Brick linings incl. insulating brickwork
HBD
Platforms, stairways
HBE
Pressure vessel (supercharged boiler)
HBK
Steam generator interior
Limit: from excl. furnace
to excl. flue gas exhaust
Printout date 14. Mrz. 01
Page HB1 of HB1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : HC
04.04.97
H
Conventional heat generation
HC
Fireside heat transfer surface cleaning equipment
HCA
Air sootblowing system
Limit: from excl. branch off supply system
HCB
Steam sootblowing system
Limit: from excl. branch off supply system
HCC
Water sootblowing system
Limit: from excl. branch off supply system
HCD
Flushing equipment
Limit: from excl. branch off supply system
HCE
Rapping gear
HCF
Shot cleaning system
HCG
Soundwave system
HCV
Lubricant supply system
HCW
Sealing fluid supply system
HCX
Fluid supply system for control and protection equipment
HCY
Control and protection equipment
Printout date 14. Mrz. 01
Page HC1 of HC1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : HD
04.04.97
H
Conventional heat generation
HD
Ash and slag removal, particulate removal
HDA
Furnace ash removal, furnace slag removal, bed ash removal
Limit: from incl. removal equipment
to excl.
discharge into disposal system or
to incl.
pressure vessel outlet or
to excl.
ash return system
HDB
Bed ash return system
Limit: from excl. furnace outlet or
from excl. bed ash removal outlet
to excl. furnace inlet
HDC
Ash return system incl. temporary storage
Limit: from incl. removal equipment for heat recovery surfaces or
from excl. *HDD*, *HDE*, *HDF*
to excl.
ash disposal system *ETG* or
to excl.
inlet to other system
HDD
Mechanical dust handling and return system
Limit: from excl. flue gas duct inlet
to excl. flue gas duct outlet or
to excl. discharge to other system
HDE
Electrostatic precipitator and return system
Limit: from excl. flue gas duct inlet
to excl. flue gas duct outlet or
to excl. discharge to other system
HDF
Cyclone dust removal and return system
Limit: from excl. flue gas duct inlet
to excl. flue gas duct outlet or
to excl. discharge to other system
HDT
Fluid supply system for ash, slag and dust moistening
Limit: from excl. intake
to excl. user
HDU
Carrier air supply system
Limit: from excl. branch off or
from incl. compressor system
to excl. inlet to carrier air system
HDV
Lubricant supply system
HDW
Sealing fluid supply system
HDX
Fluid supply system for control and protection equipment
HDY
Control and protection equipment
Printout date 14. Mrz. 01
Page HD1 of HD1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : HF
04.04.97
H
Conventional heat generation
HF
Bunker, feeder and pulverizing system
HFA
Bunker for pulverizing system
Limit: from excl. receiving point
to incl. outlet
HFB
Feeder system
Limit: from excl. bunker outlet
to excl. oversize reject shaft or pulverizing system
HFC
Pulverizing system (incl. classifier)
Limit: from incl. pulverizing system inlet
to excl.
pulverized coal line
HFD
Flue gas return system
Limit: from excl. outlet of other system
to excl. pulverizing system
HFE
Mill air system, carrier air system
Limit: from incl.
from excl.
to excl.
to excl.
to excl.
HFF
air inlet or
branch off *HLA*
downcomer shaft or
pulverizing system or
flue gas recirculation system
Vapour/exhaust gas system
Limit: from excl. separation equipment
to excl. other system
HFG
Pulverized coal temporary storage bunker after central pulverizing system
(indirect firing)
Limit: from excl. pulverizing system outlet
to incl. temporary storage bunker outlet, incl. rotary vane feeder
HFV
Lubricant supply system
HFW
Sealing fluid supply system
HFX
Fluid supply system for control and protection equipment
HFY
Control and protection equipment
Printout date 14. Mrz. 01
Page HF1 of HF1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
04.04.97
H
Conventional heat generation
HH
Main firing system (electric-powered as well)
HHA
Main burners
Limit: from incl.
HHB
Identification System for Power
Plants
Function key : HH
respective fuel-side and air-side burner inlet
Retarded combustion grate
Limit: from incl. retarded combustion grate inlet
to excl.
inlet to other system
HHC
Grate combustion system
Limit: from incl. fuel receiving point or
from incl. grate combustion inlet
to excl.
inlet to other system
HHD
Other burner equipment (e. g. vapour burner, flue dust burner)
Limit: from incl. inlet
to incl.
outlet
HHE
Pulverized coal bin, forwarding and distribution system
Limit: from excl. pulverizing system outlet or
from excl. pulverized coal bin outlet after central pulverizing system
(indirect feed) *HFG* or
from excl. outlet of other system
to excl. main burner equipment
HHF
Oil temporary storage, pump and distribution system
Limit: from excl. branch off main supply line or
from incl. temporary storage tank
to excl. main burner equipment
HHG
Gas pressure reduction, distribution system
Limit: from excl. branch off main supply line
to excl. main burner equipment
HHH
Temporary storage, forwarding and distribution system for other fuels, fluid 1
HHJ
Temporary storage, forwarding and distribution system for other fuels, fluid 2
HHK
Temporary storage, forwarding and distribution system for other fuels, fluid 3
HHL
Combustion air supply system
Limit: from incl. branch off ducting system (*HLA*)
to excl.
user
HHM
Atomizer medium supply system (steam)
Limit: from excl. branch off supply system
to excl. user
HHN
Atomizer medium supply system (air)
Limit: from excl. branch off supply system
to excl. user
HHP
Coolant supply system (steam)
Limit: from excl. branch off supply system
to excl. user
HHQ
Coolant supply system (air)
Limit: from excl. branch off supply system
to excl. user
Printout date 14. Mrz. 01
Page HH1 of HH2
Siemens
2 nd complete, non-project related edition
Condition-Date:
HHR
KKS
Identification System for Power
Plants
Function key : HH
04.04.97
Purging medium supply system (steam)
Limit: from excl. branch off supply system
to excl. user
HHS
Purging medium supply system (air)
Limit: from excl. branch off supply system
to excl. user
HHT
Heating medium supply system (steam)
Limit: from excl. branch off supply system
to excl. user and
from excl. user
to excl. inlet to other system
HHU
Heating medium supply system (hot water)
Limit: from excl. branch off supply system
to excl. user and
from excl. user
to excl. inlet to other system
HHV
Lubricant supply system
HHW
Sealing fluid supply system
HHX
Fluid supply system for control and protection equipment
HHY
Control and protection equipment
HHZ
Electric heating system
Printout date 14. Mrz. 01
Page HH2 of HH2
Siemens
2 nd complete, non-project related edition
Condition-Date:
04.04.97
H
Conventional heat generation
HJ
Ignition firing equipment (if separate)
HJA
Ignition burners
Limit: from incl.
HJE
KKS
Identification System for Power
Plants
Function key : HJ
resp. fuel-side and air-side burner inlet
Pulverized coal bin, forwarding and distribution system
Limit: from excl. pulverizing system outlet or
from excl. pulverized coal temporary storage bunker outlet
(if central pulverizing system,* HFG*) or
from excl. outlet of other system
to excl. ignition burner equipment
HJF
Oil temporary storage, pump and distribution system
Limit: from excl. branch off main supply line or
from incl. temporary storage tank
to excl. ignition burner equipment
HJG
Gas pressure reduction, distribution system
Limit: from excl. branch off main supply line
to excl. lignition burner equipment
HJL
Combustion air supply system
Limit: from incl. branch off ducting system (*HLA*) or
from incl. air inlet, incl. fan
to excl.
user
HJM
Atomizer medium supply system (steam)
Limit: from excl. branch off supply system
to excl. user
HJN
Atomizer medium supply system (air)
Limit: from excl. branch off supply system
to excl. user
HJP
Cooling supply system (steam)
Limit: from excl. branch off supply system
to excl. user
HJQ
Cooling supply system (air)
Limit: from excl. branch off supply system
to excl. user
HJR
Purging medium supply system (steam)
Limit: from excl. branch off supply system
to excl. user
HJS
Purging medium supply system (air)
Limit: from excl. branch off supply system
to excl. user
HJT
Heating medium supply system (steam)
Limit: from excl. branch off supply system
to excl. user and
from excl. user
to excl. inlet to other system
HJU
Heating medium supply system (hot water)
Limit: from excl. branch off supply system
to excl. user and
from excl. user
to excl. inlet to other system
Printout date 14. Mrz. 01
Page HJ1 of HJ2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : HJ
04.04.97
HJV
Lubricant supply system
HJW
Sealing fluid supply system
HJX
Fluid supply system for control and protection equipment
HJY
Control and protection equipment
Printout date 14. Mrz. 01
Page HJ2 of HJ2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : HL
04.04.97
H
Conventional heat generation
HL
Combustion air system (primary air, secondary air)
HLA
Ducting system
Limit: from incl. air inlet
to excl.
branch off firing system or mill air system,
carrier air system or
to excl.
branch to *HFE*, excl. fan system, air heater system
and gas turbine exhaust gas system
HLB
Fan system, forced-draught fan system
Limit: from incl. fan system inlet
to excl.
fan system outlet
HLC
External air heating system (not flue-gas-heated)
Limit: from incl. heater inlet
to incl.
heater outlet
HLD
Air heating system (flue-gas-heated)
Limit: from incl. heater inlet
to incl.
heater outlet
HLU
Air pressure relief system
Task: to relief pressure in air system
HLV
Lubricant supply system
HLW
Sealing fluid supply system
HLX
Fluid supply system for control and protection equipment
HLY
Control and protection equipment
Printout date 14. Mrz. 01
Page HL1 of HL1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : HM
04.04.97
H
Conventional heat generation
HM
Gas heating system (for closed cycle)
HMA
Primary heater (primary convection section)
Limit: from incl. cold gas inlet header or
from excl. heat exchanger cold gas outlet
to incl.
primary heater outlet or
to excl.
mixing header inlet
HMB
Radiation section
Limit: from incl. mixing header inlet
to incl.
radiation section outlet or
to excl.
secondary heater inlet header
HMC
Secondary heater (second convection section)
Limit: from incl. inlet header
to incl.
hot gas outlet header
HMD
Reheat system
Limit: from incl. reheater inlet header
to incl.
reheater outlet header
HMV
Lubricant supply system
HMW
Sealing fluid supply system
HMX
Fluid supply system for control and protection equipment
HMY
Control and protection equipment
Printout date 14. Mrz. 01
Page HM1 of HM1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : HN
04.04.97
H
Conventional heat generation
HN
Flue gas exhaust (without flue gas treatment)
HNA
Ducting system
Limit: from excl. boiler outlet or
from excl. outlet of other system
to excl. smoke stack, excl. air heater, flue gas dust handling system,
induced-draught fan system, gas scrubber system,
chemical flue gas treatment system
HNC
Induced-draught fan system
Limit: from incl. induced-draught fan system inlet
to incl.
induced-draught fan system outlet
HNE
Smoke stack system (chimney)
Limit: from incl.
HNF
inlet
Flue gas recirculation system
Limit: from excl. branch off main flue gas exhaust system
to excl. inlet to other system, incl. fan system
HNU
Flue gas pressure relief system
Task: to relief pressure in flue gas system
HNV
Lubricant supply system
HNW
Sealing fluid supply system
HNX
Fluid supply system for control and protection equipment
HNY
Control and protection equipment
Printout date 14. Mrz. 01
Page HN1 of HN1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : HR
20.01.99
H
Conventional heat generation
HR
Chemical flue gas treatment system incl. residues removal, adsorptive process
b
HRA
Flue gas ducting system within *HR.*
b
Limit: from excl. *HNA*
to excl. inlet to *HNA*
HRB
Flue gas-side heat exchanger
b
Limit: from incl. inlet
to incl.
outlet
HRC
Flue gas fan system
b
Limit: from incl. inlet
to incl.
outlet
HRD
Adsorption system (reactor)
b
Limit: from incl. inlet
to incl.
outlet
HRE
Flue gas-side cleaning equipment
b
Limit: from excl. branch off supply system
HRH
Residues separation
b
Limit: from incl. inlet
to incl.
outlet
HRJ
Fresh coke supply incl. storage
b
Limit: from excl. receiving point
to excl. fresh coke distribution system or
to excl. fresh coke treatment
HRK
Fresh coke treatment and distribution
b
Limit: from excl. fresh coke supply
to excl. reactor
HRL
Water supply and disposal system
b
HRM
Coke removal system
b
Limit: from excl. reactor
to excl. spent coke handling or
to excl. spent coke treatment
HRN
Spent coke handling incl. storage
b
Limit: from excl. coke removal or
from excl. spent coke treatment
to incl. discharge
HRP
Spent coke treatment and disposal
b
Limit: from excl. spent coke handling
to excl. spent coke handling or
to incl. discharge
HRQ
Dust extraction and disposal
b
Limit: from incl. inlet
to incl.
discharge
HRR
Inerting system
b
Limit: from incl. storage
to excl.
inlet to other system
Printout date 19. Mrz. 01
Page HR1 of HR2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : HR
20.01.99
HRV
Lubricant supply system
HRW
Sealing fluid supply system
HRX
Fluid supply system for control and protection equipment
HRY
Control and protection equipment
Printout date 19. Mrz. 01
Page HR2 of HR2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : HS
04.04.97
H
Conventional heat generation
HS
Chemical flue gas treatment system incl. residues removal, catalytic process
(e. g. DENOX)
HSA
Flue gas ducting system within *HS.*
Limit: from excl. *HNA*
to incl. evaporator system outlet and
to excl. inlet to *HNA*
HSB
Flue gas-side heat exchanger, gas heater (not *HU.*)
Limit: from incl. inlet
to incl.
outlet
HSC
Flue gas fan system
Limit: from incl. inlet
to incl.
outlet
HSD
Reactor (reduction)
Limit: from incl. inlet
to incl.
outlet
HSE
Converter (oxidation)
Limit: from incl. inlet
to incl.
outlet
HSF
Flue gas-side cleaning equipment for reactor
Limit: from excl. branch off supply system
HSG
Reduction agent dilution system
Limit: from excl. outlet of other system or
from incl. supply system
to excl. reduction agent treatment system
HSH
(Residues) separator
Limit: from incl. inlet
to incl.
outlet
HSJ
Reduction agent supply system incl. storage
HSK
Reduction agent treatment and distribution system
Limit: from excl. reduction agent supply
to incl. reduction agent injection incl. coolant inlet
HSL
Water supply and disposal system
HSM
Chemicals and additives supply system
HSN
Drainage systems
Task: water collecting, storage, return
HSP
Flyash collecting system (incl. filtering) and removal system
Limit: from incl. separator/filter or
from excl. flue gas ducting system
to excl.
inlet to disposal system
HSQ
Sprinkler system incl. drainage
Limit: from incl. inlet
to excl.
inlet to other system
HSR
Oxidizing agent treatment and distribution system
Limit: from excl. outlet converter
to excl. inlet converter
Printout date 14. Mrz. 01
Page HS1 of HS2
Siemens
2 nd complete, non-project related edition
Condition-Date:
HSS
KKS
Identification System for Power
Plants
Function key : HS
04.04.97
(Residues) forwarding, storage, loading system
Limit: from excl. outlet residues separator
HST
Flushing fluid system incl. supply
Task: flushing of reducing agent systems
HSU
Heating fluid system
Limit: from excl. heating fluid supply
to excl. evaporator inlet
from excl. evaporator outlet
to excl. inlet to other system
HSV
Lubricant supply system
HSW
Sealing fluid supply system
HSX
Fluid supply system for control and protection equipment
HSY
Control and protection equipment
Printout date 14. Mrz. 01
Page HS2 of HS2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : HT
04.04.97
H
Conventional heat generation
HT
Chemical flue gas treatment system incl. residues removal, absorptive process
(e. g. flue gas desulfurization plants)
HTA
Flue gas ducting system within *HT.*
Limit: from excl. *HNA*
to excl. inlet to *HNA*
HTB
Flue gas-side heat exchanger, gas heater (not *HU.*)
Limit: from incl. inlet
to incl.
outlet
HTC
Flue gas fan system
Limit: from incl. inlet
to incl.
outlet
HTD
Flue gas scrubbing system
Limit: from incl. flue gas inlet
to incl.
moisture separator outlet
HTE
Flue gas cleaning and filtering system
HTF
Absorption cycle
Limit: from incl. inlet
to incl.
outlet
HTG
Oxidation system incl. supply system
Limit: to excl.
HTH
user or scrubber
Flue gas cooling system
Limit: from incl. inlet flue gas cooler incl. heat dissipation system
without second heat sink
to incl.
outlet flue gas cooler
HTJ
Absorbent supply system incl. storage system
Limit: to excl.
HTK
mashing (*HTK*)
Absorbent preparation and distribution system
Limit: from incl. mashing, slaking
to excl.
user or scrubber
HTL
Piping system for discharge of solids incl. water removal and return excl.
thickening and solids dewatering systems
HTM
Thickening and solids dewatering system
Limit: from incl. inlet
to incl.
outlet
HTN
Solids drying, compacting system
HTP
(Solids/ product) forwarding, storage, loading system
HTQ
Water supply and disposal system
HTS
Chemicals and additives supply system
HTT
Drainage systems
Task: water collecting, storage, return
HTV
Lubricant supply system
HTW
Sealing fluid supply system
Printout date 14. Mrz. 01
Page HT1 of HT2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : HT
04.04.97
HTX
Fluid supply system for control and protection equipment
HTY
Control and protection equipment
Printout date 14. Mrz. 01
Page HT2 of HT2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : HU
04.04.97
H
Conventional heat generation
HU
Flue gas reheating system
HUA
Flue gas reheating system
HUB
Flue gas reheating system
HUC
Flue gas reheating system
HUD
Flue gas reheating system
HUE
Flue gas reheating system
HUF
Flue gas reheating system
HUG
Flue gas reheating system
HUH
Flue gas reheating system
HUJ
Flue gas reheating system
HUK
Flue gas reheating system
HUL
Flue gas reheating system
HUM
Flue gas reheating system
HUN
Flue gas reheating system
HUP
Flue gas reheating system
HUQ
Flue gas reheating system
HUR
Flue gas reheating system
HUS
Flue gas reheating system
HUT
Flue gas reheating system
HUU
Flue gas reheating system
HUV
Lubricant supply system
HUW
Sealing fluid supply system
HUX
Fluid supply system for control and protection equipment
HUY
Control and protection equipment
Printout date 14. Mrz. 01
Page HU1 of HU1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : HV
04.04.97
H
Conventional heat generation
HV
Lubricant supply system
HVA
Lubricant supply system
HVB
Lubricant supply system
HVC
Lubricant supply system
HVD
Lubricant supply system
HVE
Lubricant supply system
HVF
Lubricant supply system
HVG
Lubricant supply system
HVH
Lubricant supply system
HVJ
Lubricant supply system
HVK
Lubricant supply system
HVL
Lubricant supply system
HVM
Lubricant supply system
HVN
Lubricant supply system
HVP
Lubricant supply system
HVQ
Lubricant supply system
HVR
Lubricant supply system
HVS
Lubricant supply system
HVT
Lubricant supply system
HVU
Lubricant supply system
Printout date 14. Mrz. 01
Page HV1 of HV1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : HW
04.04.97
H
Conventional heat generation
HW
Sealing fluid supply system
HWA
Sealing fluid supply system
HWB
Sealing fluid supply system
HWC
Sealing fluid supply system
HWD
Sealing fluid supply system
HWE
Sealing fluid supply system
HWF
Sealing fluid supply system
HWG
Sealing fluid supply system
HWH
Sealing fluid supply system
HWJ
Sealing fluid supply system
HWK
Sealing fluid supply system
HWL
Sealing fluid supply system
HWM
Sealing fluid supply system
HWN
Sealing fluid supply system
HWP
Sealing fluid supply system
HWQ
Sealing fluid supply system
HWR
Sealing fluid supply system
HWS
Sealing fluid supply system
HWT
Sealing fluid supply system
HWU
Sealing fluid supply system
Printout date 14. Mrz. 01
Page HW1 of HW1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : HX
04.04.97
H
Conventional heat generation
HX
Fluid supply system for control and protection equipment
HXA
Fluid supply system for control and protection equipment
HXB
Fluid supply system for control and protection equipment
HXC
Fluid supply system for control and protection equipment
HXD
Fluid supply system for control and protection equipment
HXE
Fluid supply system for control and protection equipment
HXF
Fluid supply system for control and protection equipment
HXG
Fluid supply system for control and protection equipment
HXH
Fluid supply system for control and protection equipment
HXJ
Fluid supply system for control and protection equipment
HXK
Fluid supply system for control and protection equipment
HXL
Fluid supply system for control and protection equipment
HXM
Fluid supply system for control and protection equipment
HXN
Fluid supply system for control and protection equipment
HXP
Fluid supply system for control and protection equipment
HXQ
Fluid supply system for control and protection equipment
HXR
Fluid supply system for control and protection equipment
HXS
Fluid supply system for control and protection equipment
HXT
Fluid supply system for control and protection equipment
HXU
Fluid supply system for control and protection equipment
Printout date 14. Mrz. 01
Page HX1 of HX1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : HY
04.04.97
H
Conventional heat generation
HY
Control and protection equipment
HYA
Control and protection equipment
HYB
Control and protection equipment
HYC
Control and protection equipment
HYD
Control and protection equipment
HYE
Control and protection equipment
HYF
Control and protection equipment
HYG
Control and protection equipment
HYH
Control and protection equipment
HYJ
Control and protection equipment
HYK
Control and protection equipment
HYL
Control and protection equipment
HYM
Control and protection equipment
HYN
Control and protection equipment
HYP
Control and protection equipment
HYQ
Control and protection equipment
HYR
Control and protection equipment
HYS
Control and protection equipment
HYT
Control and protection equipment
HYU
Control and protection equipment
Printout date 14. Mrz. 01
Page HY1 of HY1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : J
04.04.97
J
Nuclear heat generation
JA
Reactor system
JB
Reactor vessel internals (use *JB* only if *JAC *is not sufficient for identification)
JD
Reactor control and shutdown equipment
JE
Reactor coolant system
JF
Moderator system
JG
Secondary coolant system (applicable only to three-cycle plants)
JK
Reactor core with appurtenances
Task: energy conversion
Scope: components to be removed during refueling
JM
Containment and internals
JN
Residual heat removal systems for reactor coolant system
JR
Reactor protection system
Task: to detect and identify accident conditions and
to actuate protective actions to contain and control accidents
JS
Reactor control system
Task: to control reactor state variables in normal operation
JT
Reactor operational, protective and status limitation system
JV
Lubricant supply system
JW
Sealing fluid supply system
JX
Fluid supply system for control and protection equipment
JY
Control and protection equipment (other than *JR*, *JS*, *JT*)
Printout date 14. Mrz. 01
Page J1 of J1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : JA
04.04.97
J
Nuclear heat generation
JA
Reactor system
JAA
Reactor pressure vessel
Scope: reactor pressure vessel including nozzles and
parts welded directly to the vessel
JAB
Reactor pressure vessel closure head (use only if *JAA* is not sufficient for
identification)
Scope: includes flanges, seals and bolts;
for rotating plugs incl. drives
JAC
Reactor pressure vessel internals (code reactor vessel internals under *JB* if
*JAC* not sufficient for identification)
JAD
Reactor vessel liner
Limit: liner anchor; for liners with attachment-welded piping:
to excl.
liner cooling system
JAE
Liner cooling system
Limit: connection to liner cooling system or header thereof;
otherwise incl. piping
Task: to remove heat from the liner
JAF
Reactor vessel prestressing equipment
Task: to maintain and monitor tension of prestressing cables
of reactor pressure vessel
JAG
Reactor internal insulation
Limit: associated fasterners, incl. closure head insulation
JAH
Reactor external insulation
Limit: associated fasterners, incl. closure head insulation
JAJ
Reactor vessel cooling system (only if separate from liner cooling system)
Task: to remove heat from reactor vessel wall
JAT
Leak-off system and leakage detection system
JAV
Lubricant supply system
JAW
Sealing fluid supply system
JAX
Fluid supply system for control and protection equipment
JAY
Control and protection equipment
Printout date 14. Mrz. 01
Page JA1 of JA1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : JB
04.04.97
J
Nuclear heat generation
JB
Reactor vessel internals (use *JB* only if *JAC *is not sufficient for identification)
JBA
Reactor vessel internals
JBB
Reactor vessel internals
JBC
Reactor vessel internals
JBD
Reactor vessel internals
JBE
Reactor vessel internals
JBF
Reactor vessel internals
JBG
Reactor vessel internals
JBH
Reactor vessel internals
JBJ
Reactor vessel internals
JBK
Reactor vessel internals
JBL
Reactor vessel internals
JBM
Reactor vessel internals
JBN
Reactor vessel internals
JBP
Reactor vessel internals
JBQ
Reactor vessel internals
JBR
Reactor vessel internals
JBS
Reactor vessel internals
JBT
Reactor vessel internals
JBU
Reactor vessel internals
Printout date 14. Mrz. 01
Page JB1 of JB1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : JD
04.04.97
J
Nuclear heat generation
JD
Reactor control and shutdown equipment
JDA
Control rod drive mechanism (control drive)
Limit: coupling to control assembly; connectors to power supply
Task: to move control assemblies
Scope: components that have to be removed when the reactor vessel
is opened up. Guide components welded onto the reactor vessel
to be identified under *JAC*.
JDC
Mechanical control equipment for coolant flow rate
Task: to control coolant flow rate during operation
JDE
Solid neutron absorber shutdown system
Task: to render and maintain the reactor core subcritical
JDH
Liquid neutron absorber shutdown system (extra borating system)
Task: to render and maintain the reactor core subcritical
JDJ
2nd backup liquid neutron absorber shutdown system (boron shutdown system)
Task: to render and maintain the reactor core subcritical during
specific transients
JDK
Emergency shutdown system
Task: to render and maintain the reactor core subcritical in case
of emergencies
JDM
Gaseous neutron absorber shutdown system
Task: to render and maintain the reactor core subcritical
JDP
Power supply for shutdown system
JDT
Leak-off collecting system
JDV
Lubricant supply system
JDW
Sealing fluid supply system
JDX
Fluid supply system for control and protection equipment
JDY
Control and protection equipment
Printout date 14. Mrz. 01
Page JD1 of JD1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : JE
04.04.97
J
Nuclear heat generation
JE
Reactor coolant system
JEA
Reactor coolant heat exchanger (in dual-cycle plants: steam generation system)
Limit: on primary and secondary sides
from incl. inlet heat exchanger
to incl.
outlet
JEB
Reactor coolant circulation pump system
Limit: from incl. suction nozzle
to incl.
discharge nozzle
If circulation pumps inside the reactor vessel:
to excl.
connection flange on reactor vessel
JEC
Reactor coolant piping system (not at direct-cycle plants)
Limit: from excl. reactor coolant heat exchanger
to excl. reactor coolant pumps
from excl. reactor coolant pump outlet
to excl. reactor pressure vessel
from excl. reactor pressure vessel
to excl. reactor coolant heat exchanger
JEF
Reactor coolant pressurizing system
Limit: In dual-cycle plants:
from excl. reactor coolant piping system
to incl. relief and safety valves
JEG
Reactor coolant pressure relief system (at direct-cycle plants see *LBK*)
Limit: In dual-cycle plants:
from excl. relief and safety valves
to incl. relief tank and the associated recirculation cooling equipment
In direct-cycle plants:
from excl. reactor pressure vessel
to excl. pressure suppression system
Task: to relieve impermissble pressures in the reactor coolant system
JET
Reactor coolant leak-off system
JEV
Lubricant supply system
JEW
Sealing fluid supply system
JEX
Fluid supply system for control and protection equipment
JEY
Control and protection equipment
Printout date 14. Mrz. 01
Page JE1 of JE1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : JF
04.04.97
J
Nuclear heat generation
JF
Moderator system
JFA
Moderator heat exchanger
Limit: on primary and secondary sides
from incl. inlet
to incl.
outlet
JFB
Moderator circulation system
Limit: from incl. inlet nozzle
to incl.
outlet nozzle
JFC
Moderator piping system
Limit: from excl. moderator heat exchanger
to excl. moderator circulating system
from excl. moderator circulating system
to excl. moderator tank
from incl. reactor pressure vessel
to excl. moderator heat exchanger
JFD
Moderator tank
Task: to surround the reactor core with moderator. If enclosed in
the reactor pressure vessel: identification under reactor
pressure vessel internals.
JFF
Moderator pressurizing system
Limit: from excl. moderator piping system
to incl. relief and safety valves
JFG
Moderator pressure relief system
Limit: from excl. relief and safety valves
to incl. recirculation cooling system
Task: to relieve impermissible pressures in the moderator system
JFT
Moderator leak-off system
JFV
Lubricant supply system
JFW
Sealing fluid supply system
JFX
Fluid supply system for control and protection equipment
JFY
Control and protection equipment
Printout date 14. Mrz. 01
Page JF1 of JF1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : JG
04.04.97
J
Nuclear heat generation
JG
Secondary coolant system (applicable only to three-cycle plants)
JGA
Secondary coolant heat exchanger (steam generation system)
Limit: on primary and secondary sides
from incl. inlet
to incl.
outlet
JGB
Secondary coolant circulation system
Limit: from incl. inlet nozzle
to incl.
outlet nozzle
JGC
Secondary coolant piping system
Limit: excl. circulation system and heat exchangers
JGF
Secondary coolant pressurizing system
Limit: from excl. secondary coolant piping system
to incl. relief and safety valves
JGG
Secondary coolant pressure relief system
Limit: from excl. safety valve
to incl. transfer point
Task: to relief impermissible pressures in the secondary coolant
system
JGT
Secondary coolant leak-off system
JGV
Lubricant supply system
JGW
Sealing fluid supply system
JGX
Fluid supply system for control and protection equipment
JGY
Control and protection equipment
Printout date 14. Mrz. 01
Page JG1 of JG1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : JK
04.04.97
J
Nuclear heat generation
JK
Reactor core with appurtenances
Task: energy conversion
Scope: components to be removed during refueling
JKA
Reactor core
JKB
Reactor core
JKC
Reactor core
JKD
Reactor core
JKE
Reactor core
JKF
Reactor core
JKG
Reactor core
JKH
Reactor core
JKJ
Reactor core
JKK
Reactor core
JKL
Reactor core
JKM
Reactor core
JKN
Reactor core
JKP
Reactor core
JKQ
Aeroball system
Task: to measure the flux distribution in the core by means of
mobile, activatable probes
JKS
In-core instrumentation system
Task: to measure temperature and neutron flux in the core
JKT
Ex-core instrumentation system
Task: to measure temperature and neutron flux outside the core
JKU
Failed fuel assemblies detection system
Task: to detect leaks in fuel assemblies cladding tubes
Printout date 14. Mrz. 01
Page JK1 of JK1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : JM
04.04.97
J
Nuclear heat generation
JM
Containment and internals
JMA
Containment
Task: to retain activity released from the reactor coolant system
JMC
Annulus leak-off system
Task: controlled removal of leakages from the containment
JME
Equipment airlock
Limit: weld between airlock enclosure and containment
Task: passage from compartments within the containment to the
exterior whilst maintaining the various operating conditions
JMF
Personnel airlock (motor-operated)
Limit: weld between airlock enclosure and containment
Task: passage from compartments within the containment to the
exterior whilst maintaining the various operating conditions
JMG
Emergency airlock (hand-operated)
Limit: weld between airlock enclosure and containment
Task: passage from compartments within the containment to the
exterior whilst maintaining the various operating conditions
JMH
Construction opening
Limit: weld between construction opening and containment
Task: passage from compartments within the containment to the
exterior
JMJ
Structural components inside containment (for point of installation coding only)
JMK
Piping penetration (for point of installation coding only)
JML
Cable penetration (for point of installation coding only)
JMM
Leakage monitoring and leak-off system
Task: detection and controlled removal of leakages through
penetrations and other points
JMN
Containment spray system
Limit: from incl. storage tank
to incl.
nozzle outlet
Task: to reduce pressure in containment
JMP
Pressure suppression system
Task: to limit pressure build-up in containment by condensation
Scope: suppression chamber incl. steam vent pipes, excl. parts in
common with the containment
JMT
Hydrogen reduction system (if separate from *JMU*)
Task: to reduce hydrogen concentration inside containment
JMU
Hydrogen monitoring system (also reduction and mixing if only one system)
Task: to measure hydrogen concentration in the containment atmosphere
JMV
Lubricant supply system
JMW
Sealing fluid supply system
JMX
Fluid supply system for control and protection equipment
JMY
Control and protection equipment
Printout date 14. Mrz. 01
Page JM1 of JM2
Siemens
2 nd complete, non-project related edition
Condition-Date:
JMZ
KKS
Identification System for Power
Plants
Function key : JM
04.04.97
Hydrogen mixing system (if separate from *JMU*)
Task: to mix containment atmosphere
Printout date 14. Mrz. 01
Page JM2 of JM2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : JN
04.04.97
J
Nuclear heat generation
JN
Residual heat removal systems for reactor coolant system
JNA
Residual heat removal system
Task: to remove residual heat from shutdown reactor core
JNB
Emergency residual heat removal system
Task: to remove residual heat from shutdown reactor core in case
of emergencies
JND
HP safety injection system (if separate from *JNA*)
Limit: connection to reactor coolant system
Task: to compensate small and medium size loss of coolant
JNG
LP safety injection system (if separate from *JNA*), core flooding system
Limit: connection to reactor coolant system
Task: to flood the reactor core in the event of large loss of coolant
JNK
Borated water storage system
Task: to provide borated water for residual heat removal purposes
JNP
Function testing system
Task: function testing of residual heat removal system during
operation
JNV
Lubricant supply system
JNW
Sealing fluid supply system
JNX
Fluid supply system for control and protection equipment
JNY
Control and protection equipment
Printout date 14. Mrz. 01
Page JN1 of JN1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : JR
04.04.97
J
Nuclear heat generation
JR
Reactor protection system
Task: to detect and identify accident conditions and
to actuate protective actions to contain and control accidents
JRA
Reactor protection system
JRB
Reactor protection system
JRC
Reactor protection system
JRD
Reactor protection system
JRE
Reactor protection system
JRF
Reactor protection system
JRG
Reactor protection system
JRH
Reactor protection system
JRJ
Reactor protection system
JRK
Reactor protection system
JRL
Reactor protection system
JRM
Reactor protection system
JRN
Reactor protection system
JRP
Reactor protection system
JRQ
Reactor protection system
JRR
Reactor protection system
JRS
Reactor protection system
JRT
Reactor protection system
JRU
Reactor protection system
Printout date 14. Mrz. 01
Page JR1 of JR1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : JS
04.04.97
J
Nuclear heat generation
JS
Reactor control system
Task: to control reactor state variables in normal operation
JSA
Reactor control system
JSB
Reactor control system
JSC
Reactor control system
JSD
Reactor control system
JSE
Reactor control system
JSF
Reactor control system
JSG
Reactor control system
JSH
Reactor control system
JSJ
Reactor control system
JSK
Reactor control system
JSL
Reactor control system
JSM
Reactor control system
JSN
Reactor control system
JSP
Reactor control system
JSQ
Reactor control system
JSR
Reactor control system
JSS
Reactor control system
JST
Reactor control system
JSU
Reactor control system
Printout date 14. Mrz. 01
Page JS1 of JS1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : JT
04.04.97
J
Nuclear heat generation
JT
Reactor operational, protective and status limitation system
JTA
Reactor operational, protective and status limitation system
JTB
Reactor operational, protective and status limitation system
JTC
Reactor operational, protective and status limitation system
JTD
Reactor operational, protective and status limitation system
JTE
Reactor operational, protective and status limitation system
JTF
Reactor operational, protective and status limitation system
JTG
Reactor operational, protective and status limitation system
JTH
Reactor operational, protective and status limitation system
JTJ
Reactor operational, protective and status limitation system
JTK
Reactor operational, protective and status limitation system
JTL
Reactor operational, protective and status limitation system
JTM
Reactor operational, protective and status limitation system
JTN
Reactor operational, protective and status limitation system
JTP
Reactor operational, protective and status limitation system
JTQ
Reactor operational, protective and status limitation system
JTR
Reactor operational, protective and status limitation system
JTS
Reactor operational, protective and status limitation system
JTT
Reactor operational, protective and status limitation system
JTU
Reactor operational, protective and status limitation system
Printout date 14. Mrz. 01
Page JT1 of JT1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : JV
04.04.97
J
Nuclear heat generation
JV
Lubricant supply system
JVA
Lubricant supply system
JVB
Lubricant supply system
JVC
Lubricant supply system
JVD
Lubricant supply system
JVE
Lubricant supply system
JVF
Lubricant supply system
JVG
Lubricant supply system
JVH
Lubricant supply system
JVJ
Lubricant supply system
JVK
Lubricant supply system
JVL
Lubricant supply system
JVM
Lubricant supply system
JVN
Lubricant supply system
JVP
Lubricant supply system
JVQ
Lubricant supply system
JVR
Lubricant supply system
JVS
Lubricant supply system
JVT
Lubricant supply system
JVU
Lubricant supply system
Printout date 14. Mrz. 01
Page JV1 of JV1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : JW
04.04.97
J
Nuclear heat generation
JW
Sealing fluid supply system
JWA
Sealing fluid supply system
JWB
Sealing fluid supply system
JWC
Sealing fluid supply system
JWD
Sealing fluid supply system
JWE
Sealing fluid supply system
JWF
Sealing fluid supply system
JWG
Sealing fluid supply system
JWH
Sealing fluid supply system
JWJ
Sealing fluid supply system
JWK
Sealing fluid supply system
JWL
Sealing fluid supply system
JWM
Sealing fluid supply system
JWN
Sealing fluid supply system
JWP
Sealing fluid supply system
JWQ
Sealing fluid supply system
JWR
Sealing fluid supply system
JWS
Sealing fluid supply system
JWT
Sealing fluid supply system
JWU
Sealing fluid supply system
Printout date 14. Mrz. 01
Page JW1 of JW1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : JX
04.04.97
J
Nuclear heat generation
JX
Fluid supply system for control and protection equipment
JXA
Fluid supply system for control and protection equipment
JXB
Fluid supply system for control and protection equipment
JXC
Fluid supply system for control and protection equipment
JXD
Fluid supply system for control and protection equipment
JXE
Fluid supply system for control and protection equipment
JXF
Fluid supply system for control and protection equipment
JXG
Fluid supply system for control and protection equipment
JXH
Fluid supply system for control and protection equipment
JXJ
Fluid supply system for control and protection equipment
JXK
Fluid supply system for control and protection equipment
JXL
Fluid supply system for control and protection equipment
JXM
Fluid supply system for control and protection equipment
JXN
Fluid supply system for control and protection equipment
JXP
Fluid supply system for control and protection equipment
JXQ
Fluid supply system for control and protection equipment
JXR
Fluid supply system for control and protection equipment
JXS
Fluid supply system for control and protection equipment
JXT
Fluid supply system for control and protection equipment
JXU
Fluid supply system for control and protection equipment
Printout date 14. Mrz. 01
Page JX1 of JX1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : JY
04.04.97
J
Nuclear heat generation
JY
Control and protection equipment (other than *JR*, *JS*, *JT*)
JYF
Loose parts monitoring system
Task: to detect loose and circulating parts by measurement of
structure-borne noise
JYG
Vibration monitoring system
Task: to measure and monitor operational vibrations
JYH
Leakage monitoring system
JYK
Radioactivity monitoring system
JYL
Fatigue monitoring system for components as separate system
Task: to record and process operational data for the purpose of
fatigue monitoring
Printout date 14. Mrz. 01
Page JY1 of JY1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : K
04.04.97
K
Reactor auxiliary systems
KA
Component cooling systems
KB
Coolant treatment
KH
Nuclear heat tracing systems (not electric)
Task: external heating to keep systems at operating temperature
KJ
Nuclear refrigerant systems
KL
Heating, ventilation, air-conditioning (HVAC) system in controlled areas and
exclusion areas
KP
Radioactive waste processing
KR
Nuclear gas supply and disposal (see *SE* for welding blanket gas systems)
KT
Nuclear collecting and disposal systems (also venting systems)
Limit: from incl. cheader
to excl.
radioactive waste processing or coolant
treatment systems
Task: controlled collection and disposal of fluids
KU
Nuclear sampling systems
Task: to extract and supply samples of fluids for measurement
purposes
KV
Lubricant supply system
KW
Nuclear sealing and flushing fluid supply system
Limit: from incl. storage tank
to excl.
fed system
Task: to supply fluids for sealing and flushing
KX
Fluid supply system for control and protection equipment
KY
Control and protection equipment
Printout date 14. Mrz. 01
Page K1 of K1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : KA
04.04.97
K
Reactor auxiliary systems
KA
Component cooling systems
KAA
Component cooling system for safety-related cooling loads
Limit: from excl. heat exchanger and
to excl. heat exchanger in system to be cooled
Task: to absorb and remove waste heat in a separate cooling circuit,
to prevent transfer of radioactivity to other cooling circuits
KAB
Component cooling system for process-related cooling loads
Limit: from excl. heat exchanger and
to excl. heat exchanger in system to be cooled
Task: to absorb and remove waste heat in a separate cooling circuit,
to prevent transfer of radioactivity to other cooling circuits
KAC
Component cooling system for fuel pool cooler
Limit: from excl. heat exchanger and
to excl. heat exchanger in system to be cooled
Task: to absorb and remove waste heat in a separate cooling circuit,
to prevent transfer of radioactivity to other cooling circuits
KAD
Emergency component cooling system
Limit: from excl. heat exchanger and
to excl. heat exchanger in system to be cooled
Task: to absorb and remove waste heat in case of emergencies in a
separate cooling circuit, to prevent transfer of radioactivity
to other cooling circuits
KAV
Lubricant supply system
KAW
Sealing fluid supply system
KAX
Fluid supply system for control and protection equipment
KAY
Control and protection equipment
Printout date 14. Mrz. 01
Page KA1 of KA1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : KB
04.04.97
K
Reactor auxiliary systems
KB
Coolant treatment
KBA
Level and volume control system
Task: In reactor with set liquid level: to maintain liquid level.
In reactor without set liquid level: to compensate volume.
KBB
Coolant supply system
Limit: from incl. storage tank
to excl.
fed system
Task: to store and inject process-grade coolant
KBC
Boric acid and demineralized water control system
Limit: from incl. demineralized water tank and
from incl. boric acid storage tank
to excl.
connection to fed system
KBD
Chemical control system
Limit: from incl. chemical mixing tank
to excl.
fed system
Task: to condition coolant
KBE
Coolant purification system
Task: to limit coolant impurities in the coolant system
KBF
Coolant treatment system (also evaporation)
KBG
Coolant degasification, drying system
KBH
Coolant purification regenerating system
KBJ
Tritium extraction system
KBK
Secondary coolant purification system (applicable only to three-cycle plants)
KBL
D2O/H2O purification system
KBM
D2O upgrading and distribution system
KBV
Lubricant supply system
KBW
Sealing fluid supply system
KBX
Fluid supply system for control and protection equipment
KBY
Control and protection equipment
Printout date 14. Mrz. 01
Page KB1 of KB1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : KH
04.04.97
K
Reactor auxiliary systems
KH
Nuclear heat tracing systems (not electric)
Task: external heating to keep systems at operating temperature
KHA
Heat tracing system for reactor coolant system
KHB
Heat tracing system for secondary coolant system
KHC
Heat tracing system for other systems
KHW
Sealing fluid supply system
KHX
Fluid supply system for control and protection equipment
KHY
Control and protection equipment
Printout date 14. Mrz. 01
Page KH1 of KH1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : KJ
04.04.97
K
Reactor auxiliary systems
KJ
Nuclear refrigerant systems
KJA
Low temperature system for coolant treatment
Task: to supply refrigerants below 0 °C for coolant treatment
KJB
Low temperature system for gaseous radioactive waste processing
Task: to supply refrigerants below 0 °C for gaseous radioactive
waste processing
KJL
Chilled water system for coolant treatment
Task: to supply water at about 0 °C for coolant treatment
KJM
Chilled water system for gaseous radioactive waste processing
Task: to supply water at about 0 °C for gaseous radioactive
waste processing
KJN
Chilled water system for back-up coolers
Task: to supply water at a lower temperature than that in the
component cooling system
KJP
Chilled water system for back-up coolers
KJQ
Chilled water system for back-up coolers
KJW
Sealing fluid supply system
KJX
Fluid supply system for control and protection equipment
KJY
Control and protection equipment
Printout date 14. Mrz. 01
Page KJ1 of KJ1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : KL
04.04.97
K
Reactor auxiliary systems
KL
Heating, ventilation, air-conditioning (HVAC) system in controlled areas and
exclusion areas
KLA
Heating, ventilation, air-conditioning systems
KLB
Heating, ventilation, air-conditioning systems
KLC
Heating, ventilation, air-conditioning systems
KLD
Heating, ventilation, air-conditioning systems
KLE
Heating, ventilation, air-conditioning systems
KLF
Heating, ventilation, air-conditioning systems
KLG
Heating, ventilation, air-conditioning systems
KLH
Heating, ventilation, air-conditioning systems
KLJ
Heating, ventilation, air-conditioning systems
KLK
Heating, ventilation, air-conditioning systems
KLL
Heating, ventilation, air-conditioning systems
KLM
Heating, ventilation, air-conditioning systems
KLN
Heating, ventilation, air-conditioning systems
KLP
Heating, ventilation, air-conditioning systems
KLQ
Heating, ventilation, air-conditioning systems
KLR
Heating, ventilation, air-conditioning systems
KLS
Heating, ventilation, air-conditioning systems
KLT
Heating, ventilation, air-conditioning systems
KLU
Heating, ventilation, air-conditioning systems
KLV
Lubricant supply system
KLW
Sealing fluid supply system
KLX
Fluid supply system for control and protection equipment
KLY
Control and protection equipment
Printout date 14. Mrz. 01
Page KL1 of KL1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : KP
04.04.97
K
Reactor auxiliary systems
KP
Radioactive waste processing
KPA
Solid radioactive waste processing system
KPB
Solid radioactive waste processing system
KPC
Solid radioactive waste processing system
KPD
Solid radioactive waste processing system
KPE
Solid radioactive waste storage system
KPF
Liquid radioactive waste processing system
KPG
Liquid radioactive waste processing system
KPH
Liquid radioactive waste processing system
KPJ
Liquid radioactive waste processing system
KPK
Liquid radioactive waste storage system
KPL
Gaseous radioactive waste processing system
KPM
Gaseous radioactive waste processing system
KPN
Gaseous radioactive waste processing system
KPP
Gaseous radioactive waste processing system
KPQ
Gaseous radioactive waste storage system
KPV
Lubricant supply system
KPW
Sealing fluid supply system
KPX
Fluid supply system for control and protection equipment
KPY
Control and protection equipment
Printout date 14. Mrz. 01
Page KP1 of KP1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : KR
04.04.97
K
Reactor auxiliary systems
KR
Nuclear gas supply and disposal (see *SE* for welding blanket gas systems)
KRA
Blanket gas supply
KRB
Blanket gas supply
KRC
Blanket gas supply
KRJ
Inert gas supply
KRK
Inert gas supply
KRL
Inert gas supply
KRP
Gas supply
KRQ
Gas supply
KRR
Gas supply
KRV
Lubricant supply system
KRW
Sealing fluid supply system
KRX
Fluid supply system for control and protection equipment
KRY
Control and protection equipment
Printout date 14. Mrz. 01
Page KR1 of KR1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : KT
04.04.97
K
Reactor auxiliary systems
KT
Nuclear collecting and disposal systems (also venting systems)
Limit: from incl. cheader
to excl.
radioactive waste processing or coolant
treatment systems
Task: controlled collection and disposal of fluids
KTA
Collecting systems for disposal (drained and vented fluids)
KTB
Collecting systems for disposal (drained and vented fluids)
KTC
Collecting systems for disposal (drained and vented fluids)
KTD
Collecting systems for disposal (drained and vented fluids)
KTE
Collecting systems for disposal (drained and vented fluids)
KTF
Collecting systems for disposal (drained and vented fluids)
KTG
Collecting systems for disposal (drained and vented fluids)
KTH
Collecting systems for disposal (drained and vented fluids)
KTJ
Collecting systems for disposal (drained and vented fluids)
KTK
Collecting systems for disposal (drained and vented fluids)
KTL
Collecting systems for disposal (drained and vented fluids)
KTM
Collecting systems for disposal (drained and vented fluids)
KTN
Collecting systems for disposal (drained and vented fluids)
KTP
Collecting systems for disposal (drained and vented fluids)
KTQ
Collecting systems for disposal (drained and vented fluids)
KTR
Collecting systems for disposal (drained and vented fluids)
KTS
Collecting systems for disposal (drained and vented fluids)
KTT
Collecting systems for disposal (drained and vented fluids)
KTU
Collecting systems for disposal (drained and vented fluids)
KTX
Fluid supply system for control and protection equipment
KTY
Control and protection equipment
Printout date 14. Mrz. 01
Page KT1 of KT1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : KU
04.04.97
K
Reactor auxiliary systems
KU
Nuclear sampling systems
Task: to extract and supply samples of fluids for measurement
purposes
KUA
Sampling system (liquid)
KUB
Sampling system (liquid)
KUC
Sampling system (liquid)
KUD
Sampling system (liquid)
KUE
Sampling system (liquid)
KUF
Sampling system (gaseous)
KUG
Sampling system (gaseous)
KUH
Sampling system (gaseous)
KUJ
Sampling system (gaseous)
KUK
Sampling system (gaseous)
KUL
Fault sampling system
Task: to extract samples after reactor fault out of the reactor
containment
KUM
Fault sampling system
Task: to extract samples after reactor fault out of the reactor
containment
KUN
Fault sampling system
Task: to extract samples after reactor fault out of the reactor
containment
KUX
Fluid supply system for control and protection equipment
KUY
Control and protection equipment
Printout date 14. Mrz. 01
Page KU1 of KU1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : KV
04.04.97
K
Reactor auxiliary systems
KV
Lubricant supply system
KVA
Lubricant supply system
KVB
Lubricant supply system
KVC
Lubricant supply system
KVD
Lubricant supply system
KVE
Lubricant supply system
KVF
Lubricant supply system
KVG
Lubricant supply system
KVH
Lubricant supply system
KVJ
Lubricant supply system
KVK
Lubricant supply system
KVL
Lubricant supply system
KVM
Lubricant supply system
KVN
Lubricant supply system
KVP
Lubricant supply system
KVQ
Lubricant supply system
KVR
Lubricant supply system
KVS
Lubricant supply system
KVT
Lubricant supply system
KVU
Lubricant supply system
Printout date 14. Mrz. 01
Page KV1 of KV1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : KW
04.04.97
K
Reactor auxiliary systems
KW
Nuclear sealing and flushing fluid supply system
Limit: from incl. storage tank
to excl.
fed system
Task: to supply fluids for sealing and flushing
KWA
Nuclear sealing and flushing fluid supply system
KWB
Nuclear sealing and flushing fluid supply system
KWC
Nuclear sealing and flushing fluid supply system
KWD
Nuclear sealing and flushing fluid supply system
KWE
Nuclear sealing and flushing fluid supply system
KWF
Nuclear sealing and flushing fluid supply system
KWG
Nuclear sealing and flushing fluid supply system
KWH
Nuclear sealing and flushing fluid supply system
KWJ
Nuclear sealing and flushing fluid supply system
KWK
Nuclear sealing and flushing fluid supply system
KWL
Nuclear sealing and flushing fluid supply system
KWM
Nuclear sealing and flushing fluid supply system
KWN
Nuclear sealing and flushing fluid supply system
KWP
Nuclear sealing and flushing fluid supply system
KWQ
Nuclear sealing and flushing fluid supply system
KWR
Nuclear sealing and flushing fluid supply system
KWS
Nuclear sealing and flushing fluid supply system
KWT
Nuclear sealing and flushing fluid supply system
KWU
Nuclear sealing and flushing fluid supply system
KWX
Fluid supply system for control and protection equipment
KWY
Control and protection equipment
Printout date 14. Mrz. 01
Page KW1 of KW1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : KX
04.04.97
K
Reactor auxiliary systems
KX
Fluid supply system for control and protection equipment
KXA
Fluid supply system for control and protection equipment
KXB
Fluid supply system for control and protection equipment
KXC
Fluid supply system for control and protection equipment
KXD
Fluid supply system for control and protection equipment
KXE
Fluid supply system for control and protection equipment
KXF
Fluid supply system for control and protection equipment
KXG
Fluid supply system for control and protection equipment
KXH
Fluid supply system for control and protection equipment
KXJ
Fluid supply system for control and protection equipment
KXK
Fluid supply system for control and protection equipment
KXL
Fluid supply system for control and protection equipment
KXM
Fluid supply system for control and protection equipment
KXN
Fluid supply system for control and protection equipment
KXP
Fluid supply system for control and protection equipment
KXQ
Fluid supply system for control and protection equipment
KXR
Fluid supply system for control and protection equipment
KXS
Fluid supply system for control and protection equipment
KXT
Fluid supply system for control and protection equipment
KXU
Fluid supply system for control and protection equipment
Printout date 14. Mrz. 01
Page KX1 of KX1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : KY
04.04.97
K
Reactor auxiliary systems
KY
Control and protection equipment
KYA
Control and protection equipment
KYB
Control and protection equipment
KYC
Control and protection equipment
KYD
Control and protection equipment
KYE
Control and protection equipment
KYF
Control and protection equipment
KYG
Control and protection equipment
KYH
Control and protection equipment
KYJ
Control and protection equipment
KYK
Control and protection equipment
KYL
Control and protection equipment
KYM
Control and protection equipment
KYN
Control and protection equipment
KYP
Control and protection equipment
KYQ
Control and protection equipment
KYR
Control and protection equipment
KYS
Control and protection equipment
KYT
Control and protection equipment
KYU
Control and protection equipment
Printout date 14. Mrz. 01
Page KY1 of KY1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : L
04.04.97
L
Steam, water, gas cycles
LA
Feedwater system
LB
Steam system
LC
Condensate system
LD
Condensate polishing plant
LF
Common installations for steam, water, gas cycles
LK
Gas system (closed cycle)
LL
Gas cleaning system (only for closed cycle)
LN
Water impounding works for hydroelectric power plant
LP
Intake system, upperwater system for hydroelectric power plant
LQ
Tail-race system, underwater system for hydroelectric power plant
LS
Common installations for hydroelectric power plant
LV
Lubricant supply system
LW
Sealing fluid supply system for steam, water, gas cycles
LX
Fluid supply system for control and protection equipment
LY
Control and protection equipment
Printout date 14. Mrz. 01
Page L1 of L1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : LA
04.04.97
L
Steam, water, gas cycles
LA
Feedwater system
LAA
Storage, deaeration (incl. feedwater tank)
Limit: from incl. deaerator or tank inlet
to incl.
tank outlet incl. warm-up equipment and
vapour condenser
LAB
Feedwater piping system (excl. feedwater pump and feedwater heating system)
Limit: from excl. feedwater tank outlet
to excl. boiler inlet header or heat exchanger
LAC
Feedwater pump system
Limit: from incl. pump system suction nozzle
to incl.
pump system discharge nozzle
LAD
HP feedwater heating system
Limit: from incl. respective feed heater inlet
to incl.
respective feed heater outlet incl. desuperheater
and cooler
LAE
HP desuperheating spray system
Limit: from excl. branch off feedwater piping system
to excl. user
LAF
IP desuperheating spray system
Limit: from excl. pump system discharge nozzle or
from excl. branch off other system
to excl. user
LAH
Start-up and shutdown piping system
Limit: from excl. outlet of or branch off feedwater system
to excl. feedwater piping system or other system
LAJ
Start-up and shutdown pump system
Limit: from incl. pump system suction nozzle
to incl.
pump system discharge nozzle
LAR
Emergency feedwater piping system incl. storage (excl. emergency feedwater
pump system)
Limit: from excl. branch off other system
to excl. feedwater piping system inlet
LAS
Emergency feedwater pump system
Limit: from incl. pump system suction nozzle
to incl.
pump system discharge nozzle
LAT
Back-up emergency feedwater system
Limit: from excl. branch off other system
to excl. feedwater piping system inlet
LAV
Lubricant supply system
LAW
Feedwater sealing water system
LAX
Fluid supply system for control and protection equipment
LAY
Control and protection equipment
Printout date 14. Mrz. 01
Page LA1 of LA1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : LB
04.04.97
L
Steam, water, gas cycles
LB
Steam system
LBA
Main steam piping system
Limit: from excl. boiler outlet or
from excl. heat exchanger
to excl. turbine main stop valve or HP reducing station
or turbine bypass or other user (system)
LBB
Hot reheat piping system
Limit: from excl. reheater or moisture separator/reheater outlet
to excl. intercept valve or turbine inlet or turbine bypass
or other user (system)
LBC
Cold reheat piping system
Limit: from excl. turbine outlet or high pressure reducing station
to excl. reheater inlet excl. moisture separator or
user (system)
LBD
Extraction piping system
Limit: from excl. branch off crossover line
to excl. user (system)
LBE
Back-pressure piping system
Limit: from excl. turbine outlet
to excl. user (system)
LBF
Overpressure suppression and safety device incl. injection and hydraulic station
for safety function
Limit: from excl. inlet
to incl. outlet
LBG
Auxiliary steam piping system
Limit: from excl. receiving point from other system
to excl. user (system)
LBH
Start-up steam system, shutdown steam system
Limit: from excl. boiler outlet or
from excl. branch off main steam line, incl. start-up condenser or
from excl. outlet of other system
to excl. inlet to other systems
LBJ
Moisture separator/reheater (MSR)
Limit: from incl. inlet
to incl.
outlet
LBK
Main steam safety/relief system inside reactor containment for single-cycle plants
Limit: from excl. main steam piping system
to excl. pressure suppression system
Task: pressure limitation in main steam piping system *LBA*
LBQ
Extraction steam piping system for HP feedwater heating
Limit: from excl. turbine outlet or branch off other system
to excl. feedwater heating system or user (system)
LBR
Piping system for branch or auxiliary turbine
Limit: from excl. branch off main turbine or
from excl. branch off other system or
from excl. branch or auxiliary turbine outlet
to excl. branch or auxiliary turbine isolating valve or
to excl. inlet to other system
Printout date 14. Mrz. 01
Page LB1 of LB2
Siemens
2 nd complete, non-project related edition
Condition-Date:
LBS
KKS
Identification System for Power
Plants
Function key : LB
04.04.97
Extraction steam piping system for LP feedwater heating (main condensate)
Limit: from excl. turbine outlet or branch off other system
to excl. LP feedwater heating system ot deaerator or
user (system)
LBT
Emergency condensing system
Limit: from excl. steam generator outlet or
from excl. branch off main steam piping system incl. condenser
to excl. inlet to other system
LBU
Common dump line
LBV
Lubricant supply system
LBW
Sealing steam system
LBX
Fluid supply system for control and protection equipment
LBY
Control and protection equipment
Printout date 14. Mrz. 01
Page LB2 of LB2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : LC
04.04.97
L
Steam, water, gas cycles
LC
Condensate system
LCA
Main condensate piping system (excl. main condensate pump system, LP
feedwater heating system, condensate polishing plant)
Limit: from excl. condenser outlet
to excl. deaerator inlet or
to excl. feedwater pump system (in plants without
feedwater tank)
LCB
Main condensate pump system
Limit: from incl. pump system suction nozzle
to incl.
pump system discharge nozzle
LCC
Main condensate heating system
Limit: from incl. heater inlet
to incl.
heater outlet incl.desuperheater and cooler
LCE
Condensate desuperheating spray system
Limit: from excl. branch off main condensate piping system or
from excl. branch off branch turbine condensate piping system
to excl. user
LCF
Branch turbine condensate piping system
Limit: from excl. condenser outlet
to excl. inlet to other system, excl. branch turbine condensate pump system
LCG
Branch turbine condensate pump system
Limit: from incl. pump system suction nozzle
to incl.
pump system discharge nozzle
LCH
HP heater drains system
Limit: from excl. heater outlet
to excl. inlet to other systems
LCJ
LP heater drains system
Limit: from excl. heater outlet
to excl. inlet to other systems
LCL
Steam generator drains system
Limit: from excl. branch off pressure system or
from incl. start-up flash tank
to excl. inlet to other systems
LCM
Clean drains system (collecting and return system)
Limit: from incl. collecting tank or
from excl. final drain valve or
from excl. inlet from other collecting system
to excl.
inlet to other systems
LCN
Auxiliary steam condensate system (collecting and return system)
Limit: from excl. (steam) user
to excl. inlet to other systems
LCP
Standby condensate system, incl. storage and pump system
Limit: from excl. branch off other system
to excl. inlet to other systems
LCQ
Steam generator blowdown system
Limit: from excl. steam generator outlet
from incl. blowdown flash tank (caustic flash tank)
to excl. inlet to other systems
Printout date 14. Mrz. 01
Page LC1 of LC2
Siemens
2 nd complete, non-project related edition
Condition-Date:
LCR
KKS
Identification System for Power
Plants
Function key : LC
04.04.97
Standby condensate distribution system
Limit: from excl. branch off other system
to excl. inlet to other systems
LCS
Reheater drains system (moisture separator/reheater)
Limit: from excl. reheater
to excl. inlet to other systems
LCT
Moisture separator drains system (moisture separator/reheater)
Limit: from excl. moisture separator
to excl. inlet to other systems
LCV
Lubricant supply system
LCW
Sealing and cooling drains system
Limit: from excl. branch off other system
to excl. user, incl. recirculation
LCX
Fluid supply system for control and protection equipment
LCY
Control and protection equipment
Printout date 14. Mrz. 01
Page LC2 of LC2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : LD
04.04.97
L
Steam, water, gas cycles
LD
Condensate polishing plant
LDA
Fluid treatment extraction system (if not part of another system)
Limit: from excl. fluid treatment system outlet
to excl. inlet into other system
LDB
Filtering, mechanical cleaning
Limit: from incl. separation equipment inlet
to incl.
separation equipment outlet
LDC
Aeration, gas injection system
Limit: from excl. atmosphere or
from incl. gas supply
LDD
Electromagnetic polishing system
Limit: from incl. electromagnetic polishing system inlet
to incl.
electromagnetic polishing system outlet
LDE
Acid proportioning system (e. g. for carbonate hardness removal)
Limit: from incl. acid proportioning equipment or
from excl. branch off chemicals supply system
to excl.
inlet to other system
LDF
Ion exchange, reverse osmosis system (e. g. demineralization)
Limit: from incl. ion exchanger inlet
to incl.
ion exchanger outlet
LDG
Evaporation system (e. g. demineralization)
Limit: from incl. feedwater inlet
to incl.
steam outlet and
from incl. heating steam inlet
to incl.
condensate outlet
LDH
Deaeration, drying system
Limit: from incl. deaerator or tank inlet
to incl.
tank outlet, incl. warm-up equipment of
vapour condenser
LDJ
Preheating, cooling system
Limit: from incl. preheater or cooler inlet
to incl.
preheater or cooler outlet
LDK
Piping system, temporary storage system, pump system for main fluid
Limit: Piping system:
from excl. intake or
from excl. outlet of other system
to excl. inlet to other system
to incl. fluid treatment system outlet
Temporary storage system:
from incl. temporary storage system inlet
to incl. temporary storage system outlet
Pump system:
from incl. pump system suction nozzle
to incl. pump system discharge nozzle
LDL
Storage system outside fluid treatment system (if not part of another system)
Limit: from incl. storage system inlet
to incl.
storage system outlet, incl. intake and
outfall
Printout date 14. Mrz. 01
Page LD1 of LD2
Siemens
2 nd complete, non-project related edition
Condition-Date:
LDN
KKS
Identification System for Power
Plants
Function key : LD
04.04.97
Chemicals supply system
Limit: from incl. intake or
from incl. storage tank
to excl.
discharge into other system
LDP
Regeneration, flushing equipment
Limit: from incl. system inlet
to excl.
inlet to other system
from excl. chemicals or auxiliary fluid supply system and
flushing air supply system
to incl.
regeneration, flushing equipment
LDQ
Injection system for main fluid
Limit: from incl. injection equipment or
from excl. branch off chemicals supply system
to excl.
inlet to other system
LDR
Flushing water and residues removal system incl. neutralization
Limit: from excl. outlet of respective system
to excl. discharge into disposal system
LDS
Sludge thickening system
Limit: from excl. outlet of respective system
to excl. discharge into disposal system
LDT
Heating, cooling and flushing fluid distribution system
Limit: from incl. heating, cooling, flushing fluid generation equipment or
from excl. branch off heating, cooling, flushing fluid supply system
to excl.
user and
from excl. user
LDV
Lubricant supply system
LDX
Fluid supply system for control and protection equipment
LDY
Control and protection equipment
Printout date 14. Mrz. 01
Page LD2 of LD2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : LF
04.04.97
L
Steam, water, gas cycles
LF
Common installations for steam, water, gas cycles
LFC
Common drain and vent systems
LFG
Secondary-side steam generator tubesheet lancing system
Limit: from excl. primary coolant heat exchanger outlet
to excl. primary coolant heat exchanger inlet
LFJ
Steam generator layup system
LFN
Proportioning system for feedwater, condensate system, incl. proportioning in
boiler and turbine area
Printout date 14. Mrz. 01
Page LF1 of LF1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : LK
04.04.97
L
Steam, water, gas cycles
LK
Gas system (closed cycle)
LKA
Storage system
Limit: from excl. receiving point from gas supply system
to excl. piping system inlet
LKB
Piping system
Limit: from excl. gas heater outlet
to excl. gas heater inlet, excl. turbine, compressor,
preheater, cooler
LKC
Compressor system (if separate from gas turbine)
Limit: from incl. compressor inlet
to incl.
compressor outlet
LKD
Preheating system
Limit: from incl. preheater inlet
to incl.
preheater outlet
LKE
Precooling system
Limit: from incl. precooler inlet
to incl.
precooler outlet
LKF
Intercooling system
Limit: from incl. intercooler inlet
to incl.
intercooler outlet
LKG
Pressurizing system
Limit: from incl. pressurizing system inlet
to excl.
discharge into piping system
LKV
Lubricant supply system
LKW
Sealing fluid supply system
LKX
Fluid supply system for control and protection equipment
LKY
Control and protection equipment
Printout date 14. Mrz. 01
Page LK1 of LK1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : LL
04.04.97
L
Steam, water, gas cycles
LL
Gas cleaning system (only for closed cycle)
LLA
Gas cleaning system (only for closed cycle)
LLB
Gas cleaning system (only for closed cycle)
LLC
Gas cleaning system (only for closed cycle)
LLD
Gas cleaning system (only for closed cycle)
LLE
Gas cleaning system (only for closed cycle)
LLF
Gas cleaning system (only for closed cycle)
LLG
Gas cleaning system (only for closed cycle)
LLH
Gas cleaning system (only for closed cycle)
LLJ
Gas cleaning system (only for closed cycle)
LLK
Gas cleaning system (only for closed cycle)
LLL
Gas cleaning system (only for closed cycle)
LLM
Gas cleaning system (only for closed cycle)
LLN
Gas cleaning system (only for closed cycle)
LLP
Gas cleaning system (only for closed cycle)
LLQ
Gas cleaning system (only for closed cycle)
LLR
Gas cleaning system (only for closed cycle)
LLS
Gas cleaning system (only for closed cycle)
LLT
Gas cleaning system (only for closed cycle)
LLU
Gas cleaning system (only for closed cycle)
LLW
Sealing fluid supply system
LLX
Fluid supply system for control and protection equipment
LLY
Control and protection equipment
Printout date 14. Mrz. 01
Page LL1 of LL1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : LN
04.04.97
L
Steam, water, gas cycles
LN
Water impounding works for hydroelectric power plant
LNA
Head and tail race system, storage system
Limit: from incl. water intake incl. transfer conduit and pump system
to excl.
dam (incl. measuring equipment) or
to excl.
headwater piping system or
to excl.
headrace system
LNB
Trash rack, trash/fish barrier
Limit: to excl.
LNC
inlet to other system
Dam, weir system
Limit: Dam:
from incl. foundation
to incl.
crest, incl. inspection and instrumentation equipment
Weir system:
from incl. inlet
to incl.
outlet to other system
LND
Spillway
LNE
Drainage system
LNF
Pump system
Task: pumping of the water within the head and tail race system
LNV
Lubricant supply system
LNW
Sealing fluid supply system
LNX
Fluid supply system for control and protection equipment
LNY
Control and protection equipment
Printout date 14. Mrz. 01
Page LN1 of LN1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : LP
04.04.97
L
Steam, water, gas cycles
LP
Intake system, upperwater system for hydroelectric power plant
LPA
Rake and rake cleaning system
Task: separate out and collect floating matter from headrace
LPB
Isolating equipment
Limit: from incl. isolating equipment inlet
to incl.
outlet to other system
LPC
Piping and penstock system
Limit: from incl. receiving point
to incl.
discharge into turbine system, incl.
connecting piping for pump system
LPE
Surge tank
LPV
Lubricant supply system
LPW
Sealing fluid supply system
LPX
Fluid supply system for control and protection equipment
LPY
Control and protection equipment
Printout date 14. Mrz. 01
Page LP1 of LP1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : LQ
04.04.97
L
Steam, water, gas cycles
LQ
Tail-race system, underwater system for hydroelectric power plant
LQA
Underwater piping and culvert system
Limit: from excl. main machine set *ME.*, *MF.*, *MG.* inlet
to incl. outlet to other system
LQB
Surge tank
LQC
Isolating equipment
Limit: from incl. isolating equipment inlet
to incl.
outlet to other system
LQE
Rake and rake cleaning system for pumped-storage operation
Task: separate out and collect floating matter from tailrace
LQV
Lubricant supply system
LQW
Sealing fluid supply system
LQX
Fluid supply system for control and protection equipment
LQY
Control and protection equipment
Printout date 14. Mrz. 01
Page LQ1 of LQ1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : LS
04.04.97
L
Steam, water, gas cycles
LS
Common installations for hydroelectric power plant
LSA
Common installations for hydroelectric power plant
LSB
Common installations for hydroelectric power plant
LSC
Common installations for hydroelectric power plant
LSD
Common installations for hydroelectric power plant
LSE
Common installations for hydroelectric power plant
LSF
Common installations for hydroelectric power plant
LSG
Common installations for hydroelectric power plant
LSH
Common installations for hydroelectric power plant
LSJ
Common installations for hydroelectric power plant
LSK
Common installations for hydroelectric power plant
LSL
Drainage system
LSM
Common installations for hydroelectric power plant
LSN
Common installations for hydroelectric power plant
LSP
Common installations for hydroelectric power plant
LSQ
Common installations for hydroelectric power plant
LSR
Common installations for hydroelectric power plant
LSS
Common installations for hydroelectric power plant
LST
Common installations for hydroelectric power plant
LSU
Common installations for hydroelectric power plant
Printout date 14. Mrz. 01
Page LS1 of LS1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : LV
04.04.97
L
Steam, water, gas cycles
LV
Lubricant supply system
LVA
Lubricant supply system
LVB
Lubricant supply system
LVC
Lubricant supply system
LVD
Lubricant supply system
LVE
Lubricant supply system
LVF
Lubricant supply system
LVG
Lubricant supply system
LVH
Lubricant supply system
LVJ
Lubricant supply system
LVK
Lubricant supply system
LVL
Lubricant supply system
LVM
Lubricant supply system
LVN
Lubricant supply system
LVP
Lubricant supply system
LVQ
Lubricant supply system
LVR
Lubricant supply system
LVS
Lubricant supply system
LVT
Lubricant supply system
LVU
Lubricant supply system
Printout date 14. Mrz. 01
Page LV1 of LV1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : LW
04.04.97
L
Steam, water, gas cycles
LW
Sealing fluid supply system for steam, water, gas cycles
LWA
Sealing fluid supply system for steam, water, gas cycles
LWB
Sealing fluid supply system for steam, water, gas cycles
LWC
Sealing fluid supply system for steam, water, gas cycles
LWD
Sealing fluid supply system for steam, water, gas cycles
LWE
Sealing fluid supply system for steam, water, gas cycles
LWF
Sealing fluid supply system for steam, water, gas cycles
LWG
Sealing fluid supply system for steam, water, gas cycles
LWH
Sealing fluid supply system for steam, water, gas cycles
LWJ
Sealing fluid supply system for steam, water, gas cycles
LWK
Sealing fluid supply system for steam, water, gas cycles
LWL
Sealing fluid supply system for steam, water, gas cycles
LWM
Sealing fluid supply system for steam, water, gas cycles
LWN
Sealing fluid supply system for steam, water, gas cycles
LWP
Sealing fluid supply system for steam, water, gas cycles
LWQ
Sealing fluid supply system for steam, water, gas cycles
LWR
Sealing fluid supply system for steam, water, gas cycles
LWS
Sealing fluid supply system for steam, water, gas cycles
LWT
Sealing fluid supply system for steam, water, gas cycles
LWU
Sealing fluid supply system for steam, water, gas cycles
Printout date 14. Mrz. 01
Page LW1 of LW1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : LX
04.04.97
L
Steam, water, gas cycles
LX
Fluid supply system for control and protection equipment
LXA
Fluid supply system for control and protection equipment
LXB
Fluid supply system for control and protection equipment
LXC
Fluid supply system for control and protection equipment
LXD
Fluid supply system for control and protection equipment
LXE
Fluid supply system for control and protection equipment
LXF
Fluid supply system for control and protection equipment
LXG
Fluid supply system for control and protection equipment
LXH
Fluid supply system for control and protection equipment
LXJ
Fluid supply system for control and protection equipment
LXK
Fluid supply system for control and protection equipment
LXL
Fluid supply system for control and protection equipment
LXM
Fluid supply system for control and protection equipment
LXN
Fluid supply system for control and protection equipment
LXP
Fluid supply system for control and protection equipment
LXQ
Fluid supply system for control and protection equipment
LXR
Fluid supply system for control and protection equipment
LXS
Fluid supply system for control and protection equipment
LXT
Fluid supply system for control and protection equipment
LXU
Fluid supply system for control and protection equipment
Printout date 14. Mrz. 01
Page LX1 of LX1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : LY
04.04.97
L
Steam, water, gas cycles
LY
Control and protection equipment
LYA
Control and protection equipment
LYB
Control and protection equipment
LYC
Control and protection equipment
LYD
Control and protection equipment
LYE
Control and protection equipment
LYF
Control and protection equipment
LYG
Control and protection equipment
LYH
Control and protection equipment
LYJ
Control and protection equipment
LYK
Control and protection equipment
LYL
Control and protection equipment
LYM
Control and protection equipment
LYN
Control and protection equipment
LYP
Control and protection equipment
LYQ
Control and protection equipment
LYR
Control and protection equipment
LYS
Control and protection equipment
LYT
Control and protection equipment
LYU
Control and protection equipment
Printout date 14. Mrz. 01
Page LY1 of LY1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : M
04.04.97
M
Main machine sets
MA
Steam turbine plant
MB
Gas turbine plant
MD
Wind turbine plant
ME
Hydraulic turbine plant
MF
Pumping turbine plant in pumped-storage power plants
MG
Pumped-storage plant
MJ
Diesel engine plant
MK
Generator plant
ML
Electro-motive plant (incl. motor generator)
MM
Compressor plant
MP
Common installations for main machine sets
MR
Gas engine plant
MV
Lubricant supply system
MW
Sealing fluid supply system
MX
Fluid supply system for control and protection equipment
MY
Control and protection equipment
Printout date 14. Mrz. 01
Page M1 of M1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : MA
04.04.97
M
Main machine sets
MA
Steam turbine plant
MAA
HP turbine
Limit: from incl. steam admission (main stop valve) or combined
main stop and control valve
to incl.
automatic/non-automatic extraction and exhaust
nozzles and
to incl.
the interfaces with other turbine-internal systems
MAB
IP turbine
Limit: from incl. crossover line, incl. control element or
from incl. intercept valve
to incl.
automatic/non-automatic extraction and
exhaust nozzles and
to incl.
the interfaces with other turbine-internal systems
MAC
LP turbine
Limit: from incl. crossover line, incl. control element or
from incl. intercept valve or steam inlet nozzle
(in reheat system without intercept valve)
to incl.
automatic/non-automatic extraction and
exhaust nozzles and
to incl.
the interfaces with other turbine-internal systems
MAD
Bearings
MAG
Condensing system
Limit: from incl. condenser neck or inlet nozzle
to incl.
condenser outlet nozzle, incl. connected flash
tanks, incl. instrumentation equipment associated
with condenser
MAH
Motive water system (if separate from *MAJ*)
Limit: from excl. outlet of other system
to excl. water-operated air ejector inlet
MAJ
Air removal system
Limit: from excl. condenser outlet
to excl. inlet atmosphere
MAK
Transmission gear between prime mover and driven machine, incl. turning gear
MAL
Drain and vent systems
Limit: from incl. collector point or
from incl. final drain
to excl.
discharge into other system
MAM
Leak-off steam system
Limit: from excl. branch off seal leak-off
to excl. discharge into other system
MAN
Turbine bypass station, incl. desuperheating spray system
Limit: from incl. bypass valve and
from incl. desuperheating spray valve
to incl.
steam inlet to condenser
MAP
LP turbine bypass
Limit: from excl. bypass valve and
from excl. branch off steam system
to excl. condenser
Printout date 14. Mrz. 01
Page MA1 of MA2
Siemens
2 nd complete, non-project related edition
Condition-Date:
MAQ
KKS
Identification System for Power
Plants
Function key : MA
04.04.97
Vent system (if separate from *MAL*)
Limit: from incl. venting point
to excl.
discharge into other system
MAV
Lubricant supply system
Limit: from incl. dedicated lubricant tank or common lubricant
and control fluid tank or
from excl. branch off lubricant supply system
to excl.
user and
from excl. user
MAW
Sealing, heating and cooling steam system
Limit: from excl. branch
to excl. casing nozzle of seal steam user and leak-off
to excl. condenser or
to incl. gland steam condenser or
to excl. heating/cooling steam user
MAX
Non-electric control and protection equipment, incl. fluid supply system
MAY
Electrical control and protection equipment
Printout date 14. Mrz. 01
Page MA2 of MA2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : MB
04.04.97
M
Main machine sets
MB
Gas turbine plant
MBA
Turbine, compressor rotor with common casing
Limit: from incl. compressor inlet
to incl.
compressor outlet
from incl. turbine inlet
to incl.
turbine outlet, incl. exhaust gas diffuser
MBB
Turbine casing and rotor
Limit: from incl. turbine inlet
to incl.
turbine outlet, incl. exhaust gas diffuser
MBC
Compressor casing and rotor
Limit: from incl. compressor inlet
to incl.
compressor outlet
MBD
Bearings
MBE
Coolant system for gas turbine plant
a
Limit: from excl. branch off coolant
to excl. user
MBH
Cooling and sealing gas system
Limit: from incl. extraction point
to excl.
user and
from excl. user, incl. leak-off
to incl.
inlet to other system
MBJ
Start-up unit
MBK
Transmission gear between prime mover and driven machine, incl. turning gear,
barring gear
MBL
Intake air, cold gas system (open cycle)
Limit: from excl. atmosphere
to excl. combustion chamber or
to excl. compressor inlet or
to incl. exhaust gas heat exchanger, excl. compressor
MBM
Combustion chamber (gas heating, combustion)
Limit: from incl. cold gas, fuel inlet
to incl.
hot gas outlet
MBN
Fuel supply system (liquid)
Limit: from excl. branch off main supply line or
from incl. temporary (day) tank
to excl. combustion chamber or
to excl. motive gas generating unit, incl. fuel return system
MBP
Fuel supply system (gaseous)
Limit: from excl. branch off main supply line
to excl. combustion chamber or
to excl. motive gas generating unit
MBQ
Ignition fuel supply system (if separate)
Limit: from excl. branch off main supply line or
from incl. storage tank
to excl. combustion chamber or
to excl. motive gas generating unit
Printout date 14. Mrz. 01
Page MB1 of MB2
Siemens
2 nd complete, non-project related edition
Condition-Date:
MBR
KKS
Identification System for Power
Plants
Function key : MB
04.04.97
Exhaust gas system (open cycle)
Limit: from excl. combustion chamber or
from excl. exhaust gas diffuser
to excl. discharge into atmosphere, excl. turbine or
to excl. inlet to other system (e. g. combustion air system)
MBS
Storage system
Limit: to excl.
connection to main system and
from excl. connection to main system
MBT
Motive gas generator unit, incl. combustion chamber
Limit: from incl. air/fuel inlet
to incl.
motive gas outlet of motive gas generating unit
MBU
Additive system
Limit: from incl. supply
to incl.
injection
MBV
Lubricant supply system
Limit: from incl. dedicated lubricant tank or common lubricant and
control fluid tank or
from excl. branch off control fluid supply system
to excl.
user and
from excl. user
MBW
Sealing oil supply system
Limit: from incl. dedicated seal oil tank or
from excl. seal oil pump suction line
to excl.
user and
from excl. user
MBX
Non-electric control and protection equipment, incl. fluid supply system
MBY
Electrical control and protection equipment
MBZ
Lubricant and control fluid treatment system
Printout date 14. Mrz. 01
Page MB2 of MB2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : MD
04.04.97
M
Main machine sets
MD
Wind turbine plant
MDA
Rotor (incl. hub)
MDB
Blade pitch regulating system
MDD
Rotor bearings
MDK
Transmission gear (gearbox, propeller shaft, brake)
MDL
Yaw control system
MDV
Lubricant supply system
MDX
Non-electric control and protection equipment, incl. fluid supply system
MDY
Electrical control and protection equipment
Printout date 14. Mrz. 01
Page MD1 of MD1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : ME
04.04.97
M
Main machine sets
ME
Hydraulic turbine plant
MEA
Turbine (casing, shaft, runner, draft tube etc.)
Limit: from excl. turbine inlet or
from excl. isolating valve
to incl. turbine outlet or
to excl. isolating valve
MEB
Isolating valve
Task: to isolate headwater from turbine *MEA* and/or
to control headwater flow to turbine *MEA*
MED
Bearings
MEG
Stabilizing air system
Limit: from incl. air compressor
to incl.
outlet to turbine
MEK
Transmission gear between prime mover and driven machine
MEL
Water depression air supply system
Limit: from incl. air compressor
to incl.
outlet to turbine
MES
Shaft gland cooling water system
MEV
Lubricant supply system
Limit: from incl. lubricant tank
to excl.
user and
from excl. user
MEW
Sealing water supply system
Limit: from incl. sealing water supply main isolating valve
to excl.
casing nozzle of sealing water user
MEX
Non-electric control and protection equipment, incl. fluid supply system
MEY
Electrical control and protection equipment
Printout date 14. Mrz. 01
Page ME1 of ME1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : MF
04.04.97
M
Main machine sets
MF
Pumping turbine plant in pumped-storage power plants
MFA
Pumping turbine, pump and turbine as integral unit
a
Limit: from excl. connection to pumping turbine or
from excl. isolating valve
to incl. connection to pumping turbine or
to excl. isolating valve
Task: An integral unit that at different times fulfils the task of
a prime mover (turbine) resp. a driven machine (pump)
MFB
Isolating valve
Task: to isolate water from pumping turbine *MFA* and/or
to control water flow to pumping turbine *MFA*
MFD
Bearings
MFG
Stabilizing air system
Limit: from incl. air compressor
to incl.
inlet to turbine
MFK
Transmission gear between motor generator set and pumping turbine
a
MFL
Water depression air supply system
a
Limit: from incl. air compressor
to incl.
inlet to pumping turbine
MFM
Start-up unit
MFS
Shaft gland cooling water system
MFV
Lubricant supply system
Limit: from incl. lubricant tank
to excl.
user and
from excl. user
MFW
Sealing water supply system
Limit: from incl. sealing water supply main isolating valve
to excl.
casing nozzle of sealing water user
MFX
Non-electric control and protection equipment, incl. fluid supply system
MFY
Electrical control and protection equipment
Printout date 14. Mrz. 01
Page MF1 of MF1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : MG
04.04.97
M
Main machine sets
MG
Pumped-storage plant
MGA
Storage pump (casing, shaft, runner etc.)
Limit: from excl. storage pump inlet or
from excl. isolating valve
to incl. storage pump outlet or
to excl. isolating valve
MGB
Isolating valve
Task: to isolate water from storage pump *MGA* and/or
to control water flow to storage pump *MGA*
MGD
Bearings
MGK
Transmission gear between motor generator set and storage pump
MGL
Water depression air supply system
a
Limit: from incl. air compressor
to incl.
inlet to storage pump
MGM
Start-up unit
MGS
Shaft gland cooling water system
MGV
Lubricant supply system
Limit: from incl. lubricant tank
to excl.
user and
from excl. user
MGW
Sealing water supply system
Limit: from incl. sealing water supply main isolating valve
to excl.
casing nozzle of sealing water user
MGX
Non-electric control and protection equipment, incl. fluid supply system
MGY
Electrical control and protection equipment
Printout date 14. Mrz. 01
Page MG1 of MG1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : MJ
04.04.97
M
Main machine sets
MJ
Diesel engine plant
MJA
Engine
Limit: from incl. fuel injection nozzle inlet or
from incl. air intake nozzles or
from incl. cooling water inlet nozzles
to incl.
exhaust nozzle outlet or
to incl.
cooling water nozzle outlet,
incl. engine-internal systems
MJB
Turbocharger, blower
Limit: from incl. turbocharger or blower inlet
to incl.
turbocharger or blower outlet
MJG
Liquid cooling system
Limit: from excl. engine cooling water nozzle outlet or
from incl. turbocharger air cooling system inlet
to excl. engine cooling water nozzle inlet or
to incl. turbocharger air cooler outlet
MJH
Air intercooling system
Limit: from incl. intercooler inlet
to incl.
intercooler outlet
to excl.
outlet to other cooling systems
MJK
Transmission gear between prime mover and driven machine
MJN
Fuel systems
Limit: from incl. temporary (day) tank or
from excl. branch off piping system
to excl.
fuel injection nozzle inlet
MJP
Start-up unit (incl. flywheel)
MJQ
Air intake system
Limit: from excl. atmosphere
to excl. turbocharger or
to excl. engine air intake nozzles
MJR
Exhaust gas system
Limit: from excl. engine exhaust nozzle outlet
to excl. discharge into atmosphere
MJV
Lubricant supply system
Limit: from incl. dedicated lubricant tank or common lubricant and
control fluid tank or
from excl. branch off control fluid supply system
to excl.
user
from excl. user
MJW
Sealing fluid supply system
MJX
Fluid supply system for control and protection equipment
MJY
Control and protection equipment
Printout date 14. Mrz. 01
Page MJ1 of MJ1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : MK
04.04.97
M
Main machine sets
MK
Generator plant
MKA
Generator, complete, incl. stator, rotor and all integral cooling equipment
Limit: to incl.
generator bushing
MKB
Generator exciter set, including set with electrical breaking system (use only if
*MKC* is not sufficient for identification)
MKC
Generator exciter set, including set with electrical breaking system, complete
(10 auxiliary excitation, 20 main excitation unit)
MKD
Bearings
MKF
Stator/rotor liquid cooling system, incl. coolant supply system
Hint: for cooling oil see *MKU*
Limit: from excl. stator/rotor outlet
to excl. stator/rotor inlet
Task: dissipate heat produced by stator/rotor to liquid coolant
MKG
Stator/rotor hydrogen (H2) cooling system, incl. coolant supply system
a
Hint: for nitrogen / carbon dioxyde cooling see *MKH*
Limit: from excl. stator/rotor outlet
to excl. stator/rotor inlet
Task: dissipate heat produced by stator/rotor to hydrogen coolant
MKH
Stator/rotor nitrogen (N2) / carbon dioxyde (CO2) cooling system, incl. coolant
supply system
a
Hint: for other gas cooling see *MKG*
Limit: from excl. stator/rotor outlet
to excl. stator/rotor inlet
Task: dissipate heat produced by stator/rotor to nitrogen / carbon
dioxyde coolant
MKJ
Stator/rotor air cooling system, incl. coolant supply system
Hint: for other gas cooling see *MKG* and *MKH*
Limit: from excl. stator/rotor outlet
to excl. stator/rotor inlet
Task: dissipate heat produced by stator/rotor to air coolant
MKQ
Exhaust gas system (if separate from *MKG* and *MKH*)
MKU
Stator/rotor cooling oil cooling system, incl. coolant supply system
Hint: for other liquid cooling see *MKF*
Limit: from excl. stator/rotor outlet
to excl. stator/rotor inlet
Task: dissipate heat produced by stator/rotor to cooling oil
coolant
MKV
Lubricant supply system (if separate system for generator)
MKW
Sealing oil system, incl. supply and treatment
Limit: from excl. branch off sealing oil supply system
to excl. stator inlet and
from excl. stator outlet
to excl. inlet to other system or in closed systems
from excl. stator outlet
to excl. stator inlet
MKX
Fluid supply system for control and protection equipment
Printout date 14. Mrz. 01
Page MK1 of MK2
Siemens
2 nd complete, non-project related edition
Condition-Date:
MKY
KKS
Identification System for Power
Plants
Function key : MK
04.04.97
Control and protection equipment
Printout date 14. Mrz. 01
Page MK2 of MK2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : ML
04.04.97
M
Main machine sets
ML
Electro-motive plant (incl. motor generator)
MLA
Motor frame, motor generator frame, incl. stator, rotor and all integral cooling
equipment
Limit: to incl.
motor or generator bushing
MLC
Exciter set
MLD
Bearings
MLF
Stator/rotor liquid cooling system, incl. coolant supply system
Hint: for cooling oil see *MLU*
Limit: from excl. stator/rotor outlet
to excl. stator/rotor inlet
Task: dissipate heat produced by stator/rotor to coolant
MLG
Stator/rotor gas cooling system, incl. coolant supply system
Hint: for nitrogen cooling see *MLH*
Limit: from excl. stator/rotor outlet
to excl. stator/rotor inlet
Task: dissipate heat produced by stator/rotor to coolant
MLH
Stator/rotor nitrogen cooling system, incl. coolant supply system
Hint: for other gas cooling see *MLG*
Limit: from excl. stator/rotor outlet
to excl. stator/rotor inlet
Task: dissipate heat produced by stator/rotor to coolant
MLQ
Exhaust gas system (if separate from *MLG* and *MLH*)
MLU
Stator/rotor cooling oil cooling system, incl. coolant supply system
Hint: for other liquid cooling see *MLF*
Limit: from excl. stator/rotor outlet
to excl. stator/rotor inlet
Task: dissipate heat produced by stator/rotor to coolant
MLV
Lubricant supply system (if separate system for electro-motive units)
MLW
Sealing oil system, incl. supply and treatment
Limit: from excl. branch off sealing oil supply system
to excl. stator inlet or
from excl. stator outlet
to excl. inlet to other system or in closed systems
from excl. stator outlet
to excl. stator inlet
MLX
Fluid supply system for control and protection equipment
MLY
Control and protection equipment
Printout date 14. Mrz. 01
Page ML1 of ML1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : MM
04.04.97
M
Main machine sets
MM
Compressor plant
MMA
Compressor incl. internal systems
Limit: from incl. air, cooling fluid inlet
to incl.
air, cooling fluid outlet
MMC
Air intake piping system
Limit: from excl. atmosphere
to excl. compressor inlet
MMD
Bearings
MME
Intercooling system
MMF
Aftercooling system
MMG
Final cooling system
MMH
Discharge piping system
Limit: from excl. compressor outlet
to excl. inlet to other system
MMV
Lubricant supply system
MMW
Sealing fluid supply system
MMX
Fluid supply system for control and protection equipment
MMY
Control and protection equipment
Printout date 14. Mrz. 01
Page MM1 of MM1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : MP
04.04.97
M
Main machine sets
MP
Common installations for main machine sets
MPA
Foundation
MPB
Sheating
MPG
Frame, support structure
MPR
Forced cooling system
MPS
Drying and layup system
Printout date 14. Mrz. 01
Page MP1 of MP1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : MR
04.04.97
M
Main machine sets
MR
Gas engine plant
MRA
Gas engine plant
MRB
Gas engine plant
MRC
Gas engine plant
MRD
Gas engine plant
MRE
Gas engine plant
MRF
Gas engine plant
MRG
Gas engine plant
MRH
Gas engine plant
MRJ
Gas engine plant
MRK
Gas engine plant
MRL
Gas engine plant
MRM
Gas engine plant
MRN
Gas engine plant
MRP
Gas engine plant
MRQ
Gas engine plant
MRR
Gas engine plant
MRS
Gas engine plant
MRT
Gas engine plant
MRU
Gas engine plant
MRV
Lubricant supply system
MRW
Sealing fluid supply system
MRX
Fluid supply system for control and protection equipment
MRY
Control and protection equipment
Printout date 14. Mrz. 01
Page MR1 of MR1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : MV
04.04.97
M
Main machine sets
MV
Lubricant supply system
MVA
Lubricant supply system
MVB
Lubricant supply system
MVC
Lubricant supply system
MVD
Lubricant supply system
MVE
Lubricant supply system
MVF
Lubricant supply system
MVG
Lubricant supply system
MVH
Lubricant supply system
MVJ
Lubricant supply system
MVK
Lubricant supply system
MVL
Lubricant supply system
MVM
Lubricant supply system
MVN
Lubricant supply system
MVP
Lubricant supply system
MVQ
Lubricant supply system
MVR
Lubricant supply system
MVS
Lubricant supply system
MVT
Lubricant supply system
MVU
Lubricant supply system
Printout date 14. Mrz. 01
Page MV1 of MV1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : MW
04.04.97
M
Main machine sets
MW
Sealing fluid supply system
MWA
Sealing fluid supply system
MWB
Sealing fluid supply system
MWC
Sealing fluid supply system
MWD
Sealing fluid supply system
MWE
Sealing fluid supply system
MWF
Sealing fluid supply system
MWG
Sealing fluid supply system
MWH
Sealing fluid supply system
MWJ
Sealing fluid supply system
MWK
Sealing fluid supply system
MWL
Sealing fluid supply system
MWM
Sealing fluid supply system
MWN
Sealing fluid supply system
MWP
Sealing fluid supply system
MWQ
Sealing fluid supply system
MWR
Sealing fluid supply system
MWS
Sealing fluid supply system
MWT
Sealing fluid supply system
MWU
Sealing fluid supply system
Printout date 14. Mrz. 01
Page MW1 of MW1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : MX
04.04.97
M
Main machine sets
MX
Fluid supply system for control and protection equipment
MXA
Fluid supply system for control and protection equipment
MXB
Fluid supply system for control and protection equipment
MXC
Fluid supply system for control and protection equipment
MXD
Fluid supply system for control and protection equipment
MXE
Fluid supply system for control and protection equipment
MXF
Fluid supply system for control and protection equipment
MXG
Fluid supply system for control and protection equipment
MXH
Fluid supply system for control and protection equipment
MXJ
Fluid supply system for control and protection equipment
MXK
Fluid supply system for control and protection equipment
MXL
Fluid supply system for control and protection equipment
MXM
Fluid supply system for control and protection equipment
MXN
Fluid supply system for control and protection equipment
MXP
Fluid supply system for control and protection equipment
MXQ
Fluid supply system for control and protection equipment
MXR
Fluid supply system for control and protection equipment
MXS
Fluid supply system for control and protection equipment
MXT
Fluid supply system for control and protection equipment
MXU
Fluid supply system for control and protection equipment
Printout date 14. Mrz. 01
Page MX1 of MX1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : MY
04.04.97
M
Main machine sets
MY
Control and protection equipment
MYA
Control and protection equipment
MYB
Control and protection equipment
MYC
Control and protection equipment
MYD
Control and protection equipment
MYE
Control and protection equipment
MYF
Control and protection equipment
MYG
Control and protection equipment
MYH
Control and protection equipment
MYJ
Control and protection equipment
MYK
Control and protection equipment
MYL
Control and protection equipment
MYM
Control and protection equipment
MYN
Control and protection equipment
MYP
Control and protection equipment
MYQ
Control and protection equipment
MYR
Control and protection equipment
MYS
Control and protection equipment
MYT
Control and protection equipment
MYU
Control and protection equipment
Printout date 14. Mrz. 01
Page MY1 of MY1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : N
04.04.97
N
Process energy supply for external users (e. g. district heating)
NA
Process steam system (incl. condensate return)
ND
Process hot water system
NG
Process air system
NK
Process gas system
Printout date 14. Mrz. 01
Page N1 of N1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : NA
04.04.97
N
Process energy supply for external users (e. g. district heating)
NA
Process steam system (incl. condensate return)
NAA
Piping system (steam)
NAB
Piping system (condensate)
NAD
Process heat transmission system
Limit: from incl. heat exchanger inlet
to incl.
heat exchanger outlet
NAE
Piping system (steam) (only to be used if *NAA* is not sufficient for identification)
NAF
Piping system (steam) (only to be used if *NAA* is not sufficient for identification)
NAG
Piping system (steam) (only to be used if *NAA* is not sufficient for identification)
NAH
Piping system (steam) (only to be used if *NAA* is not sufficient for identification)
NAJ
Piping system (steam) (only to be used if *NAA* is not sufficient for identification)
NAK
Piping system (condensate) (only to be used if *NAB* is not sufficient for
identification)
NAL
Piping system (condensate) (only to be used if *NAB* is not sufficient for
identification)
NAM
Piping system (condensate) (only to be used if *NAB* is not sufficient for
identification)
NAX
Fluid supply system for control and protection equipment
NAY
Control and protection equipment
Printout date 14. Mrz. 01
Page NA1 of NA1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : ND
04.04.97
N
Process energy supply for external users (e. g. district heating)
ND
Process hot water system
NDA
Piping system (forward)
NDB
Piping system (return)
NDC
Process hot water pump system
NDD
Process heat transfer
Limit: from incl. heat exchanger inlet
to incl.
heat exchanger outlet
NDE
Hot water storage system
Limit: from incl. tank inlet
to incl.
tank outlet
NDF
Distribution system
NDG
Distribution system
NDH
Distribution system
NDJ
Distribution system
NDK
Pressurizing system
NDV
Lubricant supply system
NDX
Fluid supply system for control and protection equipment
NDY
Control and protection equipment
Printout date 14. Mrz. 01
Page ND1 of ND1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : NG
04.04.97
N
Process energy supply for external users (e. g. district heating)
NG
Process air system
NGB
Piping system
NGC
Forwarding system
NGW
Sealing fluid supply system
NGX
Fluid supply system for control and protection equipment
NGY
Control and protection equipment
Printout date 14. Mrz. 01
Page NG1 of NG1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : NK
04.04.97
N
Process energy supply for external users (e. g. district heating)
NK
Process gas system
NKB
Piping system
NKW
Sealing fluid supply system
NKX
Fluid supply system for control and protection equipment
NKY
Control and protection equipment
Printout date 14. Mrz. 01
Page NK1 of NK1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : P
04.04.97
P
Cooling water systems
PA
Circulating (main cooling) water system
PB
Circulating (main cooling) water treatment system
PC
Service (secondary cooling) water system for conventional area
PD
Service (secondary cooling) water treatment system, conventional area
PE
Service (secondary cooling) water system for secured area
PF
Service (secondary cooling) water treatment system for secured area
PG
Closed cooling water system for conventional area
PH
Closed cooling water treatment system for conventional area
PJ
Closed cooling water system for secured area
PK
Closed cooling water treatment system for secured area
PM
Closed cooling water system for transformers (if separate closed cooling water
system)
PS
Cooling tower blowdown system (if separate from *PAB*)
PU
Common equipment for cooling water systems
PV
Lubricant supply system
PW
Sealing fluid supply system
PX
Fluid supply system for control and protection equipment
PY
Control and protection equipment
Printout date 14. Mrz. 01
Page P1 of P1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : PA
04.04.97
P
Cooling water systems
PA
Circulating (main cooling) water system
PAA
Extraction, mechanical cleaning for direct cooling
Limit: from incl. intake system
to incl.
mechanical cleaning system outlet
PAB
Circulating (main cooling) water piping and culvert system
Limit: from excl. outlet of circulating (main cooling) water
extraction system (excl. any user)
to incl. outfall in direct cooling system or
from excl. cooling tower outlet
to excl. cooling tower inlet in recirculation cooling
system
PAC
Circulating (main cooling) water pump system
Limit: from incl. pump system suction nozzle
to incl.
pump system discharge nozzle
PAD
Recirculating cooling system, outfall cooling system
Limit: from incl. hot water riser
to incl.
basin outlet
PAE
Cooling tower pump system (if separate)
PAH
Condenser cleaning system, incl. all appurtenances
PAR
Make-up water piping system
Limit: from excl. intake
to excl. inlet to other system
PAS
Make-up water pump system
Limit: from incl. pump system suction nozzle
to incl.
pump system discharge nozzle
PAV
Lubricant supply system
PAX
Fluid supply system for control and protection equipment
PAY
Control and protection equipment
Printout date 14. Mrz. 01
Page PA1 of PA1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : PB
04.04.97
P
Cooling water systems
PB
Circulating (main cooling) water treatment system
PBA
Discharge from fluid treatment system (if not part of another system)
Limit: from excl. fluid treatment system outlet
to excl. inlet to other system
PBB
Filtering, mechanical cleaning system
Limit: from incl. separation equipment inlet
to incl.
separation equipment outlet
PBC
Aeration, gas injection system
Limit: from excl. atmosphere or
from incl. gas supply
PBD
Precipitation system (e. g. for carbonate hardness removal)
Limit: from incl. precipitation equipment inlet
to incl.
precipitation equipment outlet
PBE
Acid proportioning system (e. g. for carbonate hardness removal)
Limit: from incl. acid dosing equipment or
from excl. branch off chemicals supply system
to excl.
inlet to other system
PBF
Ion exchange system (e. g. for demineralization)
Limit: from incl. ion exchanger inlet and
from incl. isolating valve of chemicals supply system or
auxiliary fluid supply system upstream of ion
exchanger
PBG
Evaporation system (e. g. for demineralisation)
Limit: from incl. feedwater inlet
to incl.
steam outlet and
from incl. heating steam inlet
to incl.
condensate outlet
PBH
Deaeration, drying system
Limit: from incl. deaerator or tank inlet
to incl.
tank outlet incl. warm-up equipment of vapour
condenser
PBJ
Preheating, cooling system
Limit: from incl. preheater or cooler inlet
to incl.
preheater or cooler outlet
PBK
Piping system, temporary storage system, pump system for main fluid
Limit: Piping system:
from excl. intake or
from excl. outlet of other system
to excl. inlet to other system
to incl. fluid treatment system outlet
Temporary storage system:
from incl. temporary storage system inlet
to incl. temporary storage system outlet
Pump system:
from incl. pump system suction nozzle
to incl. pump system discharge nozzle
PBL
Storage system outside fluid treatment system (if not part of another system)
Limit: from incl. storage system inlet
to incl.
storage system outlet incl. intake and outfall
Printout date 14. Mrz. 01
Page PB1 of PB2
Siemens
2 nd complete, non-project related edition
Condition-Date:
PBN
KKS
Identification System for Power
Plants
Function key : PB
04.04.97
Chemicals supply system
Limit: from incl. intake or
from incl. storage tank
to excl.
discharge into other system
PBP
Regeneration, flushing equipment
Limit: from incl. system inlet
to excl.
inlet to other system
from excl. chemicals or auxiliary fluid supply system
and flushing air supply system
to incl.
regenerating, flushing equipment
PBQ
Injection system for main fluid
Limit: from incl. injection equipment or
from excl. branch off chemicals supply system
to excl.
inlet to other system
PBR
Flushing water and residues removal system, incl. neutralization
Limit: from excl. outlet of respective system
to excl. discharge into disposal system
PBS
Sludge thickening system
Limit: from excl. outlet of respective system
to excl. discharge into other system
PBT
Heating, cooling and flushing fluid distribution system
Limit: from incl. heating, cooling, flushing fluid generation
equipment or
from excl. branch off heating, cooling, flushing fluid
supply system
to excl.
user and
from excl. user
PBV
Lubricant supply system
PBX
Fluid supply system for control and protection equipment
PBY
Control and protection equipment
Printout date 14. Mrz. 01
Page PB2 of PB2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : PC
04.04.97
P
Cooling water systems
PC
Service (secondary cooling) water system for conventional area
PCA
Extraction, mechanical cleaning for direct cooling
Limit: from incl. intake system
to incl.
mechanical cleaning system outlet
PCB
Piping and culvert system
Limit: from excl. outlet of service (secondary cooling) water extraction system or
from excl. branch off circulating water system
to excl. inlet to other system, excl. respective user and
from excl. make-up water treatment and distribution system
PCC
Pump system
Limit: from incl. pump system suction nozzle
to incl.
pump system discharge nozzle
PCD
Recirculation cooling system, outfall cooling system
Limit: from incl. hot water riser
to incl.
basin outlet
PCH
Heat exchanger cleaning system
PCM
Service (secondary cooling) water system for generator, motor generator cooling
Limit: from excl. branch off *PCB*
to excl. generator cooler and
from excl. generator cooler
to excl. inlet to *PCB* or other systems
PCV
Lubricant supply system
PCX
Fluid supply system for control and protection equipment
PCY
Control and protection equipment
Printout date 14. Mrz. 01
Page PC1 of PC1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : PD
04.04.97
P
Cooling water systems
PD
Service (secondary cooling) water treatment system, conventional area
PDA
Discharge from fluid treatment system (if not part of another system)
Limit: from excl. fluid treatment system outlet
to excl. inlet to other system
PDB
Filtering, mechanical cleaning system
Limit: from incl. separation equipment inlet
to incl.
separation equipment outlet
PDC
Aeration, gas injection system
Limit: from excl. atmosphere or
from incl. gas supply
PDD
Precipitation system (e. g. for carbonate hardness removal)
Limit: from incl. precipitation equipment inlet
to incl.
precipitation equipment outlet
PDE
Acid proportioning system (e. g. for carbonate hardness removal)
Limit: from incl. acid proportioning equipment or
from excl. branch off chemicals supply system
to excl.
inlet to other system
PDF
Ion exchange system (e. g. for demineralization)
Limit: from incl. ion exchanger inlet and
from incl. isolating valve of chemicals supply system or
auxiliary fluid supply system upstream of
ion exchanger
PDG
Evaporation system (e. g. for demineralization)
Limit: from incl. feedwater inlet
to incl.
steam outlet and
from incl. heating steam inlet
to incl.
condensate outlet
PDH
Deaeration, drying system
Limit: from incl. deaerator or tank inlet
to incl.
tank outlet incl. warm-up equipment of
vapour condenser
PDJ
Preheating, cooling system
Limit: from incl. preheater or cooler inlet
to incl.
preheater or cooler outlet
PDK
Piping system, temporary storage system, pump system for main fluid
Limit: Piping system:
from excl. intake or
from excl. outlet of other system
to excl.
inlet to other system
to incl.
fluid treatment system outlet
Temporary storage system:
from incl. temporary storage system inlet
to incl.
temporary storage system outlet
Pump system:
from incl. pump system suction nozzle
to incl.
pump system discharge nozzle
PDL
Storage system outside fluid treatment system (if not part of another system)
Limit: from incl. storage system inlet
to incl.
storage system outlet incl. intake and outfall
Printout date 14. Mrz. 01
Page PD1 of PD2
Siemens
2 nd complete, non-project related edition
Condition-Date:
PDN
KKS
Identification System for Power
Plants
Function key : PD
04.04.97
Chemicals supply system
Limit: from incl. intake or
from incl. storage tank
to excl.
discharge into other system
PDP
Regeneration, flushing equipment
Limit: from incl. system inlet
to excl.
inlet to other system
from excl. chemicals or auxiliary fluid supply system
and flushing air supply system
to incl.
regenerating, flushing equipment
PDQ
Injection system for main fluid
Limit: from incl. injection equipment or
from excl. branch off chemicals supply system
to excl.
inlet to other system
PDR
Flushing water and residues removal system, incl. neutralization
Limit: from excl. outlet of respective system
to excl. discharge into disposal system
PDS
Sludge thickening system
Limit: from excl. outlet of respective system
to excl. discharge into other system
PDT
Heating, cooling and flushing fluid distribution system
Limit: from incl. heating, cooling, flushing fluid generation
equipment or
from excl. branch off heating, cooling, flushing fluid
supply system
to excl.
user and
from excl. user
PDV
Lubricant supply system
PDX
Fluid supply system for control and protection equipment
PDY
Control and protection equipment
Printout date 14. Mrz. 01
Page PD2 of PD2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : PE
04.04.97
P
Cooling water systems
PE
Service (secondary cooling) water system for secured area
PEA
Extraction, mechanical cleaning for direct cooling
Limit: from incl. intake works
to incl.
mechanical cleaning system outlet
PEB
Piping and culvert system
Limit: from excl. outlet of service (secondary cooling) water
extraction system or
from excl. cooling tower outlet with surge pond and return
to excl. inlet to other system, excl. respective user and
from excl. make-up water treatment and distribution system
PEC
Pump system
Limit: from incl. pump system suction nozzle
to incl.
pump system discharge nozzle
PED
Recirculation cooling system, outfall cooling system
Limit: from incl. hot water riser
to incl.
basin outlet
PEH
Secured component cooler cleaning system
PEV
Lubricant supply system
PEX
Fluid supply system for control and protection equipment
PEY
Control and protection equipment
Printout date 14. Mrz. 01
Page PE1 of PE1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : PF
04.04.97
P
Cooling water systems
PF
Service (secondary cooling) water treatment system for secured area
PFA
Discharge from fluid treatment system (if not part of another system)
Limit: from excl. fluid treatment system outlet
to excl. inlet to other system
PFB
Filtering, mechanical cleaning system
Limit: from incl. separation equipment inlet
to incl.
separation equipment outlet
PFC
Aeration, gas injection system
Limit: from excl. atmosphere or
from incl. gas supply
PFD
Precipitation system (e. g. for carbonate hardness removal)
Limit: from incl. precipitation equipment inlet
to incl.
precipitation equipment outlet
PFE
Acid proportioning system (e. g. for carbonate hardness removal)
Limit: from incl. acid dosing equipment or
from excl. branch off chemicals supply system
to excl.
inlet to other system
PFF
Ion exchange system (e. g. for demineralization)
Limit: from incl. ion exchanger inlet and
from incl. isolating valve of chemicals supply system or
auxiliary fluid supply system upstream of
ion exchanger
PFG
Evaporation system (e. g. for demineralization)
Limit: from incl. feedwater inlet
to incl.
steam outlet and
from incl. heating steam inlet
to incl.
condensate outlet
PFH
Deaeration, drying system
Limit: from incl. deaerator or tank inlet
to incl.
tank outlet incl. warm-up equipment of
vapour condenser
PFJ
Preheating, cooling system
Limit: from incl. preheater or cooler inlet
to incl.
preheater or cooler outlet
PFK
Piping system, temporary storage system, pump system for main fluid
Limit: Piping system:
from excl. intake or
from excl. outlet of other system
to excl. inlet to other system
to incl. fluid treatment system outlet
Temporary storage system:
from incl. temporary storage system inlet
to incl. temporary storage system outlet
Pump system:
from incl. pump system suction nozzle
to incl. pump system discharge nozzle
PFL
Storage system outside fluid treatment system (if not part of another system)
Limit: from incl. storage system inlet
to incl.
storage system outlet incl. intake and outfall
Printout date 14. Mrz. 01
Page PF1 of PF2
Siemens
2 nd complete, non-project related edition
Condition-Date:
PFN
KKS
Identification System for Power
Plants
Function key : PF
04.04.97
Chemicals supply system
Limit: from incl. intake or
from incl. storage tank
to excl.
discharge into other system
PFP
Regeneration, flushing equipment
Limit: from incl. system inlet
to excl.
inlet to other system
from excl. chemicals or auxiliary fluid supply system
and flushing air supply system
to incl.
regenerating, flushing equipment
PFQ
Injection system for main fluid
Limit: from incl. injection equipment or
from excl. branch off chemicals supply system
to excl.
inlet to other system
PFR
Flushing water and residues removal system, incl. neutralization
Limit: from excl. outlet of respective system
to excl. discharge into disposal system
PFS
Sludge thickening system
Limit: from excl. outlet of respective system
to excl. discharge into other system
PFT
Heating, cooling and flushing fluid distribution system
Limit: from incl. heating, cooling, flushing fluid generation
equipment or
from excl. branch off heating, cooling, flushing fluid
supply system
to excl.
user and
from excl. user
PFV
Lubricant supply system
PFX
Fluid supply system for control and protection equipment
PFY
Control and protection equipment
Printout date 14. Mrz. 01
Page PF2 of PF2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : PG
04.04.97
P
Cooling water systems
PG
Closed cooling water system for conventional area
PGA
Closed cooling water system for conventional area
PGB
Closed cooling water system for conventional area
PGC
Closed cooling water system for conventional area
PGD
Closed cooling water system for conventional area
PGE
Closed cooling water system for conventional area
PGF
Closed cooling water system for conventional area
PGG
Closed cooling water system for conventional area
PGH
Closed cooling water system for conventional area
PGJ
Closed cooling water system for conventional area
PGK
Closed cooling water system for conventional area
PGL
Closed cooling water system for conventional area
PGM
Closed cooling water system for conventional area
PGN
Closed cooling water system for conventional area
PGP
Closed cooling water system for conventional area
PGQ
Closed cooling water system for conventional area
PGR
Closed cooling water system for conventional area
PGS
Closed cooling water system for conventional area
PGT
Closed cooling water system for conventional area
PGU
Closed cooling water system for conventional area
PGV
Lubricant supply system
PGX
Fluid supply system for control and protection equipment
PGY
Control and protection equipment
Printout date 14. Mrz. 01
Page PG1 of PG1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : PH
04.04.97
P
Cooling water systems
PH
Closed cooling water treatment system for conventional area
PHA
Discharge from fluid treatment system (if not part of another system)
Limit: from excl. fluid treatment system outlet
to excl. inlet to other system
PHB
Filtering, mechanical cleaning system
Limit: from incl. separation equipment inlet
to incl.
separation equipment outlet
PHC
Aeration, gas injection system
Limit: from excl. atmospere or
from incl. gas supply
PHD
Precipitation system (e. g. for carbonate hardness removal)
Limit: from incl. precipitation equipment inlet
to incl.
precipitation equipment outlet
PHE
Acid proportioning system (e. g. for carbonate hardness removal)
Limit: from incl. acid proportioning equipment or
from excl. branch off chemicals supply system
to excl.
inlet to other system
PHF
Ion exchangesystem (e. g. for demineralization)
Limit: from incl. ion exchanger inlet and
from incl. isolating valve of chemicals supply system or
auxiliary fluid supply system upstream of
ion exchanger
PHG
Evaporation system (e. g. for demineralization)
Limit: from incl. feedwater inlet
to incl.
steam outlet and
from incl. heating steam inlet
to incl.
condensate outlet
PHH
Deaeration, drying system
Limit: from incl. deaerator or tank inlet
to incl.
tank outlet, incl. warm-up equipment of
vapour condenser
PHJ
Preheating, cooling system
Limit: from incl. preheater or cooler inlet
to incl.
preheater or cooler outlet
PHK
Piping system, temporary storage system, pump system for main fluid
Limit: Piping system:
from excl. intake or
from excl. outlet of other system
to excl. inlet to other system
to incl. fluid treatment system outlet
Temporary storage system:
from incl. temporary storage system inlet
to incl. temporary storage system outlet
Pump system:
from incl. pump system suction nozzle
to incl. pump system discharge nozzle
PHL
Storage system outside fluid treatment system (if not part of another system)
Limit: from incl. storage system inlet
to incl.
storage system outlet, incl. intake and outfall
Printout date 14. Mrz. 01
Page PH1 of PH2
Siemens
2 nd complete, non-project related edition
Condition-Date:
PHN
KKS
Identification System for Power
Plants
Function key : PH
04.04.97
Chemicals supply system
Limit: from incl. intake or
from incl. storage tank
to excl.
discharge into other system
PHP
Regeneration, flushing equipment
Limit: from incl. system inlet
to excl.
inlet to other system
from excl. chemicals or auxiliary fluid supply system and
flushing air supply system
to incl.
regenerating, flushing equipment
PHQ
Injection system for main fluid
Limit: from incl. injection equipment or
from excl. branch off chemicals supply system
to excl.
inlet to other system
PHR
Flushing water and residues removal system, incl. neutralization
Limit: from excl. outlet of respective system
to excl. discharge into disposal system
PHS
Sludge thickening system
Limit: from excl. outlet of respective system
to excl. discharge into other system
PHT
Heating, cooling and flushing fluid distribution system
Limit: from incl. heating, cooling, flushing fluid generation
equipment or
from excl. branch off heating, cooling, flushing fluid
supply system
to excl.
user and
from excl. user
PHV
Lubricant supply system
PHX
Fluid supply system for control and protection equipment
PHY
Control and protection equipment
Printout date 14. Mrz. 01
Page PH2 of PH2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : PJ
04.04.97
P
Cooling water systems
PJ
Closed cooling water system for secured area
PJA
Closed cooling water system for secured area
PJB
Closed cooling water system for secured area
PJC
Closed cooling water system for secured area
PJD
Closed cooling water system for secured area
PJE
Closed cooling water system for secured area
PJF
Closed cooling water system for secured area
PJG
Closed cooling water system for secured area
PJH
Closed cooling water system for secured area
PJJ
Closed cooling water system for secured area
PJK
Closed cooling water system for secured area
PJL
Closed cooling water system for secured area
PJM
Closed cooling water system for secured area
PJN
Closed cooling water system for secured area
PJP
Closed cooling water system for secured area
PJQ
Closed cooling water system for secured area
PJR
Closed cooling water system for secured area
PJS
Closed cooling water system for secured area
PJT
Closed cooling water system for secured area
PJU
Closed cooling water system for secured area
PJV
Lubricant supply system
PJX
Fluid supply system for control and protection equipment
PJY
Control and protection equipment
Printout date 14. Mrz. 01
Page PJ1 of PJ1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : PK
04.04.97
P
Cooling water systems
PK
Closed cooling water treatment system for secured area
PKA
Discharge from fluid treatment system (if not part of another system)
Limit: from excl. fluid treatment system outlet
to excl. inlet to other system
PKB
Filtering, mechanical cleaning system
Limit: from incl. separation equipment inlet
to incl.
separation equipment outlet
PKC
Aeration, gas injection system
Limit: from excl. atmosphere or
from incl. gas supply
PKD
Precipitation system (e. g. for carbonate hardness removal)
Limit: from incl. precipitation equipment inlet
to incl.
precipitation equipment outlet
PKE
Acid proportioning system (e. g. for carbonate hardness removal)
Limit: from incl. acid proportioning equipment or
from excl. branch off chemicals supply system
to excl.
inlet to other system
PKF
Ion exchange system (e. g. for demineralization)
Limit: from incl. ion exchanger inlet and
from incl. isolating valve of chemicals supply system or
auxiliary fluid supply system upstream of
ion exchanger
PKG
Evaporation system (e. g. for demineralization)
Limit: from incl. feedwater inlet
to incl.
steam outlet and
from incl. heating steam inlet
to incl.
condensate outlet
PKH
Deaeration, drying system
Limit: from incl. deaerator or tank inlet
to incl.
tank outlet, incl. warm-up equipment of
vapour condenser
PKJ
Preheating, cooling system
Limit: from incl. preheater or cooler inlet
to incl.
preheater or cooler outlet
PKK
Piping system, temporary storage system, pump system for main fluid
Limit: Piping system:
from excl. intake or
from excl. outlet of other system
to excl. inlet to other system
to incl. fluid treatment system outlet
Temporary storage system:
from incl. temporary storage system inlet
to incl. temporary storage system outlet
Pump system:
from incl. pump system suction nozzle
to incl. pump system discharge nozzle
PKL
Storage system outside fluid treatment system (if not part of another system)
Limit: from incl. storage system inlet
to incl.
storage system outlet, incl. intake and outfall
Printout date 14. Mrz. 01
Page PK1 of PK2
Siemens
2 nd complete, non-project related edition
Condition-Date:
PKN
KKS
Identification System for Power
Plants
Function key : PK
04.04.97
Chemicals supply system
Limit: from incl. intake or
from incl. storage tank
to excl.
discharge into other system
PKP
Regeneration, flushing equipment
Limit: from incl. system inlet
to excl.
inlet to other system
from excl. chemicals or auxiliary fluid supply system and
flushing air supply system
to incl.
regenerating, flushing equipment
PKQ
Injection system for main fluid
Limit: from incl. injection equipment or
from excl. branch off chemicals supply system
to excl.
inlet to other system
PKR
Flushing water and residues removal system, incl. neutralization
Limit: from excl. outlet of respective system
to excl. discharge into disposal system
PKS
Sludge thickening system
Limit: from excl. outlet of respective system
to excl. discharge into other system
PKT
Heating, cooling and flushing fluid distribution system
Limit: from incl. heating, cooling, flushing fluid generation
equipment or
from excl. branch off heating, cooling, flushing fluid
supply system
to excl.
user and
from excl. user
PKV
Lubricant supply system
PKX
Fluid supply system for control and protection equipment
PKY
Control and protection equipment
Printout date 14. Mrz. 01
Page PK2 of PK2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : PM
04.04.97
P
Cooling water systems
PM
Closed cooling water system for transformers (if separate closed cooling water
system)
PMA
Closed cooling water system for transformers
PMB
Closed cooling water system for transformers
PMC
Closed cooling water system for transformers
PMD
Closed cooling water system for transformers
PME
Closed cooling water system for transformers
PMF
Closed cooling water system for transformers
PMG
Closed cooling water system for transformers
PMH
Closed cooling water system for transformers
PMJ
Closed cooling water system for transformers
PMK
Closed cooling water system for transformers
PML
Closed cooling water system for transformers
PMM
Closed cooling water system for transformers
PMN
Closed cooling water system for transformers
PMP
Closed cooling water system for transformers
PMQ
Closed cooling water system for transformers
PMR
Closed cooling water system for transformers
PMS
Closed cooling water system for transformers
PMT
Closed cooling water system for transformers
PMU
Closed cooling water system for transformers
PMV
Lubricant supply system
PMX
Fluid supply system for control and protection equipment
PMY
Control and protection equipment
Printout date 14. Mrz. 01
Page PM1 of PM1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : PS
04.04.97
P
Cooling water systems
PS
Cooling tower blowdown system (if separate from *PAB*)
PSA
Cooling tower blowdown system
PSB
Cooling tower blowdown system
PSC
Cooling tower blowdown system
PSD
Cooling tower blowdown system
PSE
Cooling tower blowdown system
PSF
Cooling tower blowdown system
PSG
Cooling tower blowdown system
PSH
Cooling tower blowdown system
PSJ
Cooling tower blowdown system
PSK
Cooling tower blowdown system
PSL
Cooling tower blowdown system
PSM
Cooling tower blowdown system
PSN
Cooling tower blowdown system
PSP
Cooling tower blowdown system
PSQ
Cooling tower blowdown system
PSR
Cooling tower blowdown system
PSS
Cooling tower blowdown system
PST
Cooling tower blowdown system
PSU
Cooling tower blowdown system
PSV
Lubricant supply system
PSX
Fluid supply system for control and protection equipment
PSY
Control and protection equipment
Printout date 14. Mrz. 01
Page PS1 of PS1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : PU
04.04.97
P
Cooling water systems
PU
Common equipment for cooling water systems
PUA
Common equipment for cooling water systems
PUB
Common equipment for cooling water systems
PUC
Common equipment for cooling water systems
PUD
Common equipment for cooling water systems
PUE
Common equipment for cooling water systems
PUF
Common equipment for cooling water systems
PUG
Common equipment for cooling water systems
PUH
Common equipment for cooling water systems
PUJ
Common equipment for cooling water systems
PUK
Common equipment for cooling water systems
PUL
Common equipment for cooling water systems
PUM
Common equipment for cooling water systems
PUN
Proportioning equipment
PUP
Common equipment for cooling water systems
PUQ
Common equipment for cooling water systems
PUR
Impressed current cathodic protection for mechanical equipment within the
cooling water system
PUS
Common equipment for cooling water systems
PUT
Common equipment for cooling water systems
PUU
Common equipment for cooling water systems
Printout date 14. Mrz. 01
Page PU1 of PU1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : PV
04.04.97
P
Cooling water systems
PV
Lubricant supply system
PVA
Lubricant supply system
PVB
Lubricant supply system
PVC
Lubricant supply system
PVD
Lubricant supply system
PVE
Lubricant supply system
PVF
Lubricant supply system
PVG
Lubricant supply system
PVH
Lubricant supply system
PVJ
Lubricant supply system
PVK
Lubricant supply system
PVL
Lubricant supply system
PVM
Lubricant supply system
PVN
Lubricant supply system
PVP
Lubricant supply system
PVQ
Lubricant supply system
PVR
Lubricant supply system
PVS
Lubricant supply system
PVT
Lubricant supply system
PVU
Lubricant supply system
Printout date 14. Mrz. 01
Page PV1 of PV1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : PW
04.04.97
P
Cooling water systems
PW
Sealing fluid supply system
PWA
Sealing fluid supply system
PWB
Sealing fluid supply system
PWC
Sealing fluid supply system
PWD
Sealing fluid supply system
PWE
Sealing fluid supply system
PWF
Sealing fluid supply system
PWG
Sealing fluid supply system
PWH
Sealing fluid supply system
PWJ
Sealing fluid supply system
PWK
Sealing fluid supply system
PWL
Sealing fluid supply system
PWM
Sealing fluid supply system
PWN
Sealing fluid supply system
PWP
Sealing fluid supply system
PWQ
Sealing fluid supply system
PWR
Sealing fluid supply system
PWS
Sealing fluid supply system
PWT
Sealing fluid supply system
PWU
Sealing fluid supply system
Printout date 14. Mrz. 01
Page PW1 of PW1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : PX
04.04.97
P
Cooling water systems
PX
Fluid supply system for control and protection equipment
PXA
Fluid supply system for control and protection equipment
PXB
Fluid supply system for control and protection equipment
PXC
Fluid supply system for control and protection equipment
PXD
Fluid supply system for control and protection equipment
PXE
Fluid supply system for control and protection equipment
PXF
Fluid supply system for control and protection equipment
PXG
Fluid supply system for control and protection equipment
PXH
Fluid supply system for control and protection equipment
PXJ
Fluid supply system for control and protection equipment
PXK
Fluid supply system for control and protection equipment
PXL
Fluid supply system for control and protection equipment
PXM
Fluid supply system for control and protection equipment
PXN
Fluid supply system for control and protection equipment
PXP
Fluid supply system for control and protection equipment
PXQ
Fluid supply system for control and protection equipment
PXR
Fluid supply system for control and protection equipment
PXS
Fluid supply system for control and protection equipment
PXT
Fluid supply system for control and protection equipment
PXU
Fluid supply system for control and protection equipment
Printout date 14. Mrz. 01
Page PX1 of PX1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : PY
04.04.97
P
Cooling water systems
PY
Control and protection equipment
PYA
Control and protection equipment
PYB
Control and protection equipment
PYC
Control and protection equipment
PYD
Control and protection equipment
PYE
Control and protection equipment
PYF
Control and protection equipment
PYG
Control and protection equipment
PYH
Control and protection equipment
PYJ
Control and protection equipment
PYK
Control and protection equipment
PYL
Control and protection equipment
PYM
Control and protection equipment
PYN
Control and protection equipment
PYP
Control and protection equipment
PYQ
Control and protection equipment
PYR
Control and protection equipment
PYS
Control and protection equipment
PYT
Control and protection equipment
PYU
Control and protection equipment
Printout date 14. Mrz. 01
Page PY1 of PY1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : Q
04.04.97
Q
Auxiliary systems
QC
Central chemicals supply
QE
General compressed air and carrier air supply
QF
General control air supply
QG
Central gas supply for closed gas cycles (as working fluid)
QH
Auxiliary steam generating system
QJ
Central gas supply, also inert gas (see *SE* for welding blanket gas supply
systems, see *MK*, *ML*, *XK*, *XL* for central gas supply systems for main
and heavy machinery)
QK
Chilled water systems for conventional area
QL
Feedwater, steam, condensate cycle of auxiliary steam generating and
distribution system
QM
Air humidifying system
QS
Central oil supply and disposal system (for systems assignable to more than one
F1-function)
QU
Sampling systems for conventional area
Printout date 14. Mrz. 01
Page Q1 of Q1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : QC
04.04.97
Q
Auxiliary systems
QC
Central chemicals supply
QCA
Central chemicals supply
QCB
Central chemicals supply
QCC
Central chemicals supply
QCD
Central chemicals supply
QCE
Central chemicals supply
QCF
Central chemicals supply
QCG
Central chemicals supply
QCH
Central chemicals supply
QCJ
Central chemicals supply
QCK
Central chemicals supply
QCL
Central chemicals supply
QCM
Central chemicals supply
QCN
Central chemicals supply
QCP
Central chemicals supply
QCQ
Central chemicals supply
QCR
Central chemicals supply
QCS
Central chemicals supply
QCT
Central chemicals supply
QCU
Central chemicals supply
QCV
Lubricant supply system
QCX
Fluid supply system for control and protection equipment
QCY
Control and protection equipment
Printout date 14. Mrz. 01
Page QC1 of QC1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : QE
04.04.97
Q
Auxiliary systems
QE
General compressed air and carrier air supply
QEA
Central compressed air and carrier air generation system
QEB
Central compressed air and carrier air distribution system
QEC
General compressed air and carrier air supply
QED
General compressed air and carrier air supply
QEE
General compressed air and carrier air supply
QEF
General compressed air and carrier air supply
QEG
General compressed air and carrier air supply
QEH
General compressed air and carrier air supply
QEJ
General compressed air and carrier air supply
QEK
General compressed air and carrier air supply
QEL
General compressed air and carrier air supply
QEM
General compressed air and carrier air supply
QEN
General compressed air and carrier air supply
QEP
General compressed air and carrier air supply
QEQ
General compressed air and carrier air supply
QER
General compressed air and carrier air supply
QES
General compressed air and carrier air supply
QET
General compressed air and carrier air supply
QEU
General compressed air and carrier air supply
QEV
Lubricant supply system
QEW
Sealing fluid supply system
QEX
Fluid supply system for control and protection equipment
QEY
Control and protection equipment
Printout date 14. Mrz. 01
Page QE1 of QE1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : QF
04.04.97
Q
Auxiliary systems
QF
General control air supply
QFA
Central control air generation system
QFB
Central control air distribution system
QFC
General control air supply
QFD
General control air supply
QFE
General control air supply
QFF
General control air supply
QFG
General control air supply
QFH
General control air supply
QFJ
General control air supply
QFK
General control air supply
QFL
General control air supply
QFM
General control air supply
QFN
General control air supply
QFP
General control air supply
QFQ
General control air supply
QFR
General control air supply
QFS
General control air supply
QFT
General control air supply
QFU
General control air supply
QFV
Lubricant supply system
QFW
Sealing fluid supply system
QFX
Fluid supply system for control and protection equipment
QFY
Control and protection equipment
Printout date 14. Mrz. 01
Page QF1 of QF1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : QG
04.04.97
Q
Auxiliary systems
QG
Central gas supply for closed gas cycles (as working fluid)
QGA
Central gas supply for closed gas cycles (as working fluid)
QGB
Central gas supply for closed gas cycles (as working fluid)
QGC
Central gas supply for closed gas cycles (as working fluid)
QGD
Central gas supply for closed gas cycles (as working fluid)
QGE
Central gas supply for closed gas cycles (as working fluid)
QGF
Central gas supply for closed gas cycles (as working fluid)
QGG
Central gas supply for closed gas cycles (as working fluid)
QGH
Central gas supply for closed gas cycles (as working fluid)
QGJ
Central gas supply for closed gas cycles (as working fluid)
QGK
Central gas supply for closed gas cycles (as working fluid)
QGL
Central gas supply for closed gas cycles (as working fluid)
QGM
Central gas supply for closed gas cycles (as working fluid)
QGN
Central gas supply for closed gas cycles (as working fluid)
QGP
Central gas supply for closed gas cycles (as working fluid)
QGQ
Central gas supply for closed gas cycles (as working fluid)
QGR
Central gas supply for closed gas cycles (as working fluid)
QGS
Central gas supply for closed gas cycles (as working fluid)
QGT
Central gas supply for closed gas cycles (as working fluid)
QGU
Central gas supply for closed gas cycles (as working fluid)
QGV
Lubricant supply system
QGW
Sealing fluid supply system
QGX
Fluid supply system for control and protection equipment
QGY
Control and protection equipment
Printout date 14. Mrz. 01
Page QG1 of QG1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : QH
04.04.97
Q
Auxiliary systems
QH
Auxiliary steam generating system
QHA
Pressure system
QHB
Support structure, enclosure, steam generator interior
QHC
Fireside heat transfer surface cleaning equipment
QHD
Ash and slag removal
QHE
Blowdown system, flash drain system
QHF
Bunker, feeder and pulverizing system
QHG
Boiler water circulation system (also for electrode steam boiler)
QHH
Main firing system (electric-powered as well)
QHJ
Ignition firing equipment (if separate)
QHL
Combustion air system (primary air, secondary air)
QHM
Gas heating system (for closed cycle)
QHN
Flue gas exhaust (without flue gas treatment)
QHP
Mechanical dust handling system
QHQ
Electrostatic precipitator
QHR
Chemical flue gas treatment system, incl. residues removal, adsorptive process
QHS
Chemical flue gas treatment system, incl. residues removal, catalytic process
QHT
Chemical flue gas treatment system, incl. residues removal, absorptive process
QHU
Flue gas reheating system
QHV
Lubricant supply system
QHX
Fluid supply system for control and protection equipment
QHY
Control and protection equipment
Printout date 14. Mrz. 01
Page QH1 of QH1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : QJ
04.04.97
Q
Auxiliary systems
QJ
Central gas supply, also inert gas (see *SE* for welding blanket gas supply
systems, see *MK*, *ML*, *XK*, *XL* for central gas supply systems for main
and heavy machinery)
QJA
Central gas supply, also inert gas
QJB
Central gas supply, also inert gas
QJC
Central gas supply, also inert gas
QJD
Central gas supply, also inert gas
QJE
Central gas supply, also inert gas
QJF
Central gas supply, also inert gas
QJG
Central gas supply, also inert gas
QJH
Central gas supply, also inert gas
QJJ
Central gas supply, also inert gas
QJK
Central gas supply, also inert gas
QJL
Central gas supply, also inert gas
QJM
Central gas supply, also inert gas
QJN
Central gas supply, also inert gas
QJP
Central gas supply, also inert gas
QJQ
Central gas supply, also inert gas
QJR
Central gas supply, also inert gas
QJV
Lubricant supply system
QJW
Sealing fluid supply system
QJX
Fluid supply system for control and protection equipment
QJY
Control and protection equipment
Printout date 14. Mrz. 01
Page QJ1 of QJ1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : QK
04.04.97
Q
Auxiliary systems
QK
Chilled water systems for conventional area
QKA
Chilled water systems for conventional area
QKB
Chilled water systems for conventional area
QKC
Chilled water systems for conventional area
QKD
Chilled water systems for conventional area
QKE
Chilled water systems for conventional area
QKF
Chilled water systems for conventional area
QKG
Chilled water systems for conventional area
QKH
Chilled water systems for conventional area
QKJ
Chilled water systems for conventional area
QKK
Chilled water systems for conventional area
QKL
Chilled water systems for conventional area
QKM
Chilled water systems for conventional area
QKN
Chilled water systems for conventional area
QKP
Chilled water systems for conventional area
QKQ
Chilled water systems for conventional area
QKR
Chilled water systems for conventional area
QKS
Chilled water systems for conventional area
QKT
Chilled water systems for conventional area
QKU
Chilled water systems for conventional area
QKV
Lubricant supply system
QKX
Fluid supply system for control and protection equipment
QKY
Control and protection equipment
Printout date 14. Mrz. 01
Page QK1 of QK1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : QL
04.04.97
Q
Auxiliary systems
QL
Feedwater, steam, condensate cycle of auxiliary steam generating and
distribution system
QLA
Feedwater system
QLB
Steam system
QLC
Condensate system
QLD
Condensate polishing plant
QLF
Common equipment for auxiliary steam generation and distribution systems
QLV
Lubricant supply system
QLX
Fluid supply system for control and protection equipment
QLY
Control and protection equipment
Printout date 14. Mrz. 01
Page QL1 of QL1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : QM
04.04.97
Q
Auxiliary systems
QM
Air humidifying system
QMA
Air humidifying system
QMB
Air humidifying system
QMC
Air humidifying system
QMD
Air humidifying system
QME
Air humidifying system
QMF
Air humidifying system
QMG
Air humidifying system
QMH
Air humidifying system
QMJ
Air humidifying system
QMK
Air humidifying system
QML
Air humidifying system
QMM
Air humidifying system
QMN
Air humidifying system
QMP
Air humidifying system
QMQ
Air humidifying system
QMR
Air humidifying system
QMS
Air humidifying system
QMT
Air humidifying system
QMU
Air humidifying system
QMV
Lubricant supply system
QMX
Fluid supply system for control and protection equipment
QMY
Control and protection equipment
Printout date 14. Mrz. 01
Page QM1 of QM1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : QS
04.04.97
Q
Auxiliary systems
QS
Central oil supply and disposal system (for systems assignable to more than one
F1-function)
QSA
Central oil supply and disposal system
QSB
Central oil supply and disposal system
QSC
Central oil supply and disposal system
QSD
Central oil supply and disposal system
QSE
Central oil supply and disposal system
QSF
Central oil supply and disposal system
QSG
Central oil supply and disposal system
QSH
Central oil supply and disposal system
QSJ
Central oil supply and disposal system
QSK
Central oil supply and disposal system
QSL
Central oil supply and disposal system
QSM
Central oil supply and disposal system
QSN
Central oil supply and disposal system
QSP
Central oil supply and disposal system
QSQ
Central oil supply and disposal system
QSR
Central oil supply and disposal system
QSS
Central oil supply and disposal system
QST
Central oil supply and disposal system
QSU
Central oil supply and disposal system
QSV
Lubricant supply system
QSX
Fluid supply system for control and protection equipment
QSY
Control and protection equipment
Printout date 14. Mrz. 01
Page QS1 of QS1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : QU
04.04.97
Q
Auxiliary systems
QU
Sampling systems for conventional area
QUA
Sampling systems for conventional area
QUB
Sampling systems for conventional area
QUC
Sampling systems for conventional area
QUD
Sampling systems for conventional area
QUE
Sampling systems for conventional area
QUF
Sampling systems for conventional area
QUG
Sampling systems for conventional area
QUH
Sampling systems for conventional area
QUJ
Sampling systems for conventional area
QUK
Sampling systems for conventional area
QUL
Sampling systems for conventional area
QUM
Sampling systems for conventional area
QUN
Sampling systems for conventional area
QUP
Sampling systems for conventional area
QUQ
Sampling systems for conventional area
QUR
Sampling systems for conventional area
QUS
Sampling systems for conventional area
QUT
Sampling systems for conventional area
QUU
Sampling systems for conventional area
QUX
Fluid supply system for control and protection equipment
QUY
Control and protection equipment
Printout date 14. Mrz. 01
Page QU1 of QU1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : R
04.04.97
R
Gas generation and treatment
RA
Gas generation
RB
Support structure
RC
Feedstock systems
RD
Discharge systems for gasification residues
RE
Gasifying agent generation and distribution
RG
Main gas cooling systems (if not *RA*)
RH
Main gas piping systems, storage, compression, expansion
RJ
Main gas precipitator
RK
Main gas clean-up (not *RJ*) including regeneration
RL
Acid gas, including treatment systems
RM
Gas recycle, storage and compression systems
RN
Collection, storage and recycle systems for gas condensate
RP
Inert gas, including recovery systems
RS
Supply and removal systems for water, steam and condensate
RT
Waste water collection and drainage systems
RU
Waste water treatment systems
RV
Lubricant supply systems
RW
Sealing fluid supply systems
RX
Fluid supply systems for control and protection equipment
RY
Control and protection equipment
RZ
Injection and proportioning systems
Printout date 14. Mrz. 01
Page R1 of R1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : RA
04.04.97
R
Gas generation and treatment
RA
Gas generation
RAA
Gas generator
Limit: from incl. fuel, ignition fuel and fluxing agent inlet or
from excl. burner and nozzle system
to excl.
removal system or
to excl.
solids separator and reycle system or
to excl.
gas generator quench gas section or
to incl.
main gas outlet
RAB
Gas generator interior
RAC
Gas generator internals
RAD
Lining and refractory brickwork
RAE
Cooling system
Limit: from incl. gas generator cooling system inlet
to incl.
gas generator cooling system outlet
RAF
Solids separator and recycle system
Limit: from excl. gas generator outlet
to excl. gas generator inlet
to incl. main gas outlet
RAG
Gas generator quench gas section
Limit: from incl. quench gas section inlet
to incl.
quench gas section outlet
RAH
Main burner system
Limit: from excl. feedstock system or
from excl. gasifying agent generation and distribution system
to excl. gas generator interior
RAJ
Pilot burner system
Limit: from excl. pilot burner fuel storage and distribution system or
from excl. gasifying agent generation and distribution system
to excl. gas generator interior
RAK
Gas generator ignition and standby burner system incl. combustion air system
Limit: from excl. ignition fuel storage and distribution system or
from incl. combustion air inlet
to excl. gas generator interior
RAL
Ignition and standby hot gas generation and feed system incl. combustion air
system
Limit: from excl. ignition fuel storage and distribution system or
from incl. combustion air inlet
to excl. gas generator interior
RAM
Separate gasifying agent injection system
Limit: from excl. gasifying agent generation and distribution system
to excl. gas generator interior
RAN
Injection from gas recycle system
Limit: from excl. gas recycle system
to excl. gas generator interior
RAP
Gas condensate injection system
Limit: from excl. gas recycle system for gas condensate
to excl. gas generator interior
Printout date 14. Mrz. 01
Page RA1 of RA2
Siemens
2 nd complete, non-project related edition
Condition-Date:
RAQ
KKS
Identification System for Power
Plants
Function key : RA
04.04.97
Injection system for other feedstock
Limit: from excl. other feedstock system
to excl. gas generator interior
RAR
Fluxing agent injection system
Limit: from excl. feed system for fluxing agents
to excl. gas generator interior
RAS
Filter cleaning system
Limit: from excl. branch off supply system
RAT
Fluidizing air injection system
Limit: from excl. fluidizing gas piping system
to excl. gas generator interior
RAV
Lubricant supply system
RAW
Sealing fluid supply system
RAX
Fluid supply system for control and protection equipment
RAY
Control and protection equipment
Printout date 14. Mrz. 01
Page RA2 of RA2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : RB
04.04.97
R
Gas generation and treatment
RB
Support structure
RBA
Frame including foundations
RBB
Enclosures, insulations
RBD
Platforms and stairways
RBE
Support structure (available for use as process demands)
RBF
Support structure (available for use as process demands)
Printout date 14. Mrz. 01
Page RB1 of RB1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : RC
04.04.97
R
Gas generation and treatment
RC
Feedstock systems
RCA
Fuel storage bunker, hopper (atmospheric pressure)
Limit: from excl. receiving point
to excl. distribution and transport system (atmospheric pressure)
RCB
Distribution and transport system (atmospheric pressure)
Limit: from excl. fuel storage bunker, hopper outlet
to excl. pulverizing and mixing system (slurry) or
to excl. air lock system, slurry pump system
RCC
Pulverizing and mixing system (slurry)
Limit: from excl. distribution and transport system (atmospheric pressure)
to excl. airlock system, slurry pump system
RCE
Airlock system, slurry pump system
Limit: from excl. distribution and transport system (atmospheric pressure) or
from excl. pulverizing and mixing system (slurry)
to excl. fuel hopper (pressurized)
RCF
Fuel storage bunker, container (pressurized)
Limit: from excl. airlock system, slurry pump system
to excl. distribution and transport system (pressurized)
RCG
Distribution and transport system (pressurized)
Limit: from excl. fuel hopper (pressurized)
to excl. gas generator or
to excl. main burner system
RCJ
Ignition fuel storage and distribution system
Limit: from excl. ignition fuel supply system
to excl. gas generator or
to excl. gas generator ignition and standby burner system or
to excl. ignition and standby hot gas generation and
feed system or
to excl. feedstock system
RCK
Pilot burner fuel storage and distribution system
Limit: from excl. fuel supply system
to excl. pilot burner system
RCL
Proportioning system for other feedstock
Limit: from excl. supply system
to excl. gas generator or
to excl. feedstock system
RCM
Proportioning system for fluxing agents
Limit: from excl. supply system
to excl. gas generator or
to excl. feed system for fluxing agents
RCS
Filter cleaning system
Limit: from excl. branch off supply system
RCV
Lubricant supply system
RCW
Sealing fluid supply system
RCX
Fluid supply system for control and protection equipment
RCY
Control and protection equipment
Printout date 14. Mrz. 01
Page RC1 of RC1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : RD
04.04.97
R
Gas generation and treatment
RD
Discharge systems for gasification residues
RDA
Collection, transport and treatment system (pressurized) (system 1)
Limit: from excl. receiving point
to excl. gas generator or
to excl. pressure relief system
RDB
Pressure relief system (system 1)
Limit: from excl. collection, transport and treatment system (pressurized)
to excl. collection, transport and treatment system (atmospheric pressure)
RDC
Collection, transport and treatment system (atmospheric pressure) (system 1)
Limit: from excl. pressure relief system
to excl. transport and treatment system for fuel
conversion residues or
to excl. feedstock system
RDE
Collection, transport and treatment system (pressurized) (system 2)
Limit: from excl. receiving point
to excl. gas generator or
to excl. pressure relief system
RDF
Pressure relief system (system 2)
Limit: from excl. collection, transport and treatment system (pressurized)
to excl. collection, transport and treatment system (atmospheric pressure)
RDG
Collection, transport and treatment system (atmospheric pressure) (system 2)
Limit: from excl. pressure relief system
to excl. transport and treatment system for fuel
conversion residues or
to excl. feedstock system
RDJ
Collection, transport and treatment system (pressurized) (system 3)
Limit: from excl. receiving point
to excl. gas generator or
to excl. pressure relief system
RDK
Pressure relief system (system 3)
Limit: from excl. collection, transport and treatment system (pressurized)
to excl. collection, transport and treatment system (atmospheric pressure)
RDL
Collection, transport and treatment system (atmospheric pressure) (system 3)
Limit: from excl. pressure relief system
to excl. transport and treatment system for fuel
conversion residues or
to excl. feedstock system
RDN
Collection, transport and treatment system (pressurized) (system 4)
Limit: from excl. receiving point
to excl. gas generator or
to excl. pressure relief system
RDP
Pressure relief system (system 4)
Limit: from excl. collection, transport and treatment system (pressurized)
to excl. collection, transport and treatment system (atmospheric pressure)
RDQ
Collection, transport and treatment system (atmospheric pressure) (system 4)
Limit: from excl. pressure relief system
to excl. transport and treatment system for fuel
conversion residues or
to excl. feedstock system
Printout date 14. Mrz. 01
Page RD1 of RD2
Siemens
2 nd complete, non-project related edition
Condition-Date:
RDS
KKS
Identification System for Power
Plants
Function key : RD
04.04.97
Filter cleaning system
Limit: from excl. branch off supply system
RDV
Lubricant supply system
RDW
Sealing fluid supply system
RDX
Fluid supply system for control and protection equipment
RDY
Control and protection equipment
Printout date 14. Mrz. 01
Page RD2 of RD2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : RE
04.04.97
R
Gas generation and treatment
RE
Gasifying agent generation and distribution
REA
Air (gasifying agent) compression and supercompression system
Limit: from excl. atmosphere or
from excl. compressor casing outlet of gas turbine
to excl. compressed air distribution system or
to excl. gasifying agent heater
REB
Gasifying agent heater (other than *RGC*)
Limit: from incl. preheater inlet
to incl.
preheater outlet or
to incl.
preheater outlet incl. desuperheater
REC
Compressed air distribution system (incl. oxygen-enriched air)
Limit: from excl. air (gasifying agent) compression and
supercompression system outlet or
from excl. oxygen piping system (pressurized) or
from excl. other system
to excl. other system or
to excl. main burner system or
to excl. pilot burner system or
to excl. separate gasifying agent injection system
REE
Air compression and supercompression system upstream of air separation plant
Limit: from excl. atmosphere or
from excl. compressor casing outlet of gas turbine
to incl. air compression and supercompression system
outlet upstream of air separation plant
REF
Air separation plant
Limit: from excl. air (gasifying agent) compression and supercompression
system outlet upstream of air separation plant
to excl. oxygen piping system (pressurized) or
to excl. oxygen compression and supercompression system or
to excl. liquid oxygen discharge system or
to excl. discharge system for other gases (inert gases)
from air separation plant or
to excl. liquid nitrogen discharge system or
to excl. inert gas, including recovery system or
to excl. nitrogen piping system (*RPG*)
REG
Oxygen compression and supercompression system
Limit: from incl. oxygen compression and supercompression system inlet
to incl.
oxygen compression and supercompression system outlet
REH
Oxygen piping system (pressurized)
Limit: from excl. air separation plant or
from excl. oxygen compression and supercompression system or
from excl. other system
to excl. other system or
to excl. main burner system or
to excl. pilot burner system or
to excl. separate gasifying agent injection system
REJ
Liquid oxygen outlet system
Limit: from excl. air separation plant
to excl. oxygen piping system (pressurized) or
to excl. other system
Printout date 14. Mrz. 01
Page RE1 of RE2
Siemens
2 nd complete, non-project related edition
Condition-Date:
REK
KKS
Identification System for Power
Plants
Function key : RE
04.04.97
Discharge system for other gases from air separation plant (inert gases)
Limit: from excl. air separation plant
to incl. dispatch facility or
to excl. other system
REL
Liquid nitrogen discharge system
Limit: from excl. air separation plant
to excl. inert gas, including recovery system or
to excl. other system or
to incl. dispatch facility
REP
External oxygen supply system
Limit: from excl. receiving point
to excl. oxygen compression and supercompression system or
to excl. oxygen piping system (pressurized)
RER
Gasifying steam system
Limit: from excl. water/steam system or
from excl. other system
to excl. main burner system or
to excl. pilot burner system or
to excl. separate gasifying agent injection system
REV
Lubricant supply system
REW
Sealing fluid supply system
REX
Fluid supply system for control and protection equipment
REY
Control and protection equipment
Printout date 14. Mrz. 01
Page RE2 of RE2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : RG
04.04.97
R
Gas generation and treatment
RG
Main gas cooling systems (if not *RA*)
RGA
Indirect heat transfer to water/steam cycle
Limit: from incl. main gas inlet or
from incl. water/steam inlet
to incl.
main gas outlet or
to incl.
water/steam outlet or
to incl.
gas condensate outlet
RGB
Indirect heat transfer to gas
Limit: from incl.
from incl.
from incl.
to incl.
to incl.
to incl.
to incl.
RGC
main gas inlet or
gas recycle system inlet or
inert gas inlet
main gas outlet or
gas recycle system outlet or
inert gas outlet or
gas condensate outlet
Indirect heat transfer to gasifying agent
Limit: from incl. main gas inlet or
from incl. gasifying agent inlet
to incl.
main gas outlet or
to incl.
gasifying agent outlet or
to incl.
gas condensate outlet
RGD
Indirect heat transfer to combustion air
Limit: from incl. main gas inlet or
from incl. combustion air inlet
to incl.
main gas outlet or
to incl.
combustion air outlet or
to incl.
gas condensate outlet
RGE
Indirect heat transfer to cooling water
Limit: from incl. main gas inlet or
from incl. cooling water inlet
to incl.
main gas outlet or
to incl.
cooling water outlet or
to incl.
gas condensate outlet
RGJ
Direct heat transfer (quench) to gas
Limit: from incl. main gas inlet or
from incl. coolant inlet
from excl. coolant supply line
to incl.
main gas outlet
RGK
Direct heat transfer (quench, saturation) to steam
RGL
Direct heat transfer (quench, saturation) to water
RGM
Direct heat transfer (quench) to other fluids
RGS
Filter cleaning system
Limit: from excl. branch off supply system
RGV
Lubricant supply system
RGW
Sealing fluid supply system
RGX
Fluid supply system for control and protection equipment
RGY
Control and protection equipment
Printout date 14. Mrz. 01
Page RG1 of RG2
Siemens
2 nd complete, non-project related edition
Condition-Date:
RGZ
KKS
Identification System for Power
Plants
Function key : RG
04.04.97
Injection and proportioning system
Printout date 14. Mrz. 01
Page RG2 of RG2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : RH
04.04.97
R
Gas generation and treatment
RH
Main gas piping systems, storage, compression, expansion
RHA
Main gas piping system
Limit: from excl. other system
to excl. other system
RHE
Humidification system
Limit: from excl. main gas piping system or
from excl. water/steam cycle or
from excl. collection, storage and recycle system for gas condensate
to excl. main gas piping system or
to excl. water/steam cycle or
to excl. collection, storage and recycle system for gas condensate
RHF
Conditioning system 1
Limit: from excl. branch off supply system or
from incl. unloading facility
RHG
Conditioning system 2
Limit: from excl. branch off supply system or
from incl. unloading facility
RHK
Gas storage system
Limit: from excl. main gas piping system or
from excl. gas compression system
to excl. main gas piping system or
to excl. gas pressure reducing system
RHM
Gas compression system
Limit: from excl. main gas piping system
to excl. main gas piping system or
to excl. gas storage system or
to excl. gas recycle system
RHN
Gas pressure reducing system
Limit: from excl. main gas piping system or
from excl. gas storage system
to excl. main gas piping system or
to excl. other system
RHP
Flare system 1
Limit: from excl. main gas piping system
to incl. flare system outlet
RHQ
Flare system 2
Limit: from excl. main gas piping system
to incl. flare system outlet
RHS
Filter cleaning system
Limit: from excl. branch off supply system
RHV
Lubricant supply system
RHW
Sealing fluid supply system
RHX
Fluid supply system for control and protection equipment
RHY
Control and protection equipment
RHZ
Injection and proportioning system
Printout date 14. Mrz. 01
Page RH1 of RH1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : RJ
04.04.97
R
Gas generation and treatment
RJ
Main gas precipitator
RJA
Cartridge filter system
Limit: from incl. cartridge filter inlet
from excl. filter cleaning system
to incl.
cartridge filter outlet
to excl.
gasification residues removal system
RJB
Cyclone filter system
Limit: from incl. cyclone filter inlet
from excl. filter cleaning system
to incl.
cyclone filter outlet
to excl.
gasification residues removal system
RJC
Bag filter system
Limit: from incl. bag filter inlet
from excl. filter cleaning system
to incl.
bag filter outlet
to excl.
gasification residues removal system
RJD
Packed-bed filter system
Limit: from incl. packed-bed filter inlet
from excl. filter cleaning system
to incl.
packed-bed filter outlet
to excl.
gasification residues removal system
RJE
Electrostatic precipitator system
Limit: from incl. electrostatic precipitator inlet
from excl. filter cleaning system
to incl.
electrostatic precipitator outlet
to excl.
gasification residues removal system
RJS
Filter cleaning system
Limit: from excl. branch off supply system
RJV
Lubricant supply system
RJW
Sealing fluid supply system
RJX
Fluid supply system for control and protection equipment
RJY
Control and protection equipment
Printout date 14. Mrz. 01
Page RJ1 of RJ1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : RK
04.04.97
R
Gas generation and treatment
RK
Main gas clean-up (not *RJ*) including regeneration
RKA
Scrubber system
Limit: from incl. inlet
to incl.
outlet
RKB
Conversion system including hydrolysis
Limit: from incl. inlet
to incl.
outlet
RKC
Gas purification system
Limit: from incl. inlet
to incl.
outlet
RKG
Scrubber regeneration system 1
Limit: from incl. inlet
to incl.
outlet
RKH
Scrubber regeneration system 2
Limit: from incl. inlet
to incl.
outlet
RKJ
Scrubber regeneration system 3
Limit: from incl. inlet
to incl.
outlet
RKL
Regeneration system 1 for purification system
Limit: from incl. inlet
to incl.
outlet
RKM
Regeneration system 2 for purification system
Limit: from incl. inlet
to incl.
outlet
RKN
Regeneration system 3 for purification system
Limit: from incl. inlet
to incl.
outlet
RKQ
Refrigeration system
Limit: from incl. inlet
to incl.
outlet
RKV
Lubricant supply system
RKW
Sealing fluid supply system
RKX
Fluid supply system for control and protection equipment
RKY
Control and protection equipment
RKZ
Injection and proportioning system
Printout date 14. Mrz. 01
Page RK1 of RK1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : RL
04.04.97
R
Gas generation and treatment
RL
Acid gas, including treatment systems
RLA
Thermal treatment (Claus process)
Limit: from incl. inlet
to incl.
outlet
RLB
Catalytic treatment (Claus process)
Limit: from incl. inlet
to incl.
outlet
RLE
Absorber, wet oxidation system
Limit: from incl. inlet
to incl.
outlet
RLH
Thermal treatment (tail gas)
Limit: from incl. inlet
to incl.
outlet
RLJ
Catalytic treatment (tail gas)
Limit: from incl. inlet
to incl.
outlet
RLK
Absorption treatment (tail gas)
Limit: from incl. inlet
to incl.
outlet
RLN
Sulphur treatment system
Limit: from incl. inlet
to incl.
outlet
RLP
Sulphur forwarding and storage system
Limit: from incl. inlet
to incl.
outlet
RLR
Sulphuric acid system
Limit: from incl. inlet
to incl.
outlet
RLS
Sulphuric acid storage system
Limit: from incl. inlet
to incl.
outlet
RLW
Sealing fluid supply system
RLX
Fluid supply system for control and protection equipment
RLY
Control and protection equipment
RLZ
Injection and proportioning system
Printout date 14. Mrz. 01
Page RL1 of RL1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : RM
04.04.97
R
Gas generation and treatment
RM
Gas recycle, storage and compression systems
RMA
Quench gas piping system
Limit: from excl. main gas piping system or
from excl. branch off other system
to excl. direct heat transfer (quench) to gas or
to excl. gas generator quench gas section
RMB
Piping system for expanded gas (not from airlock system)
Limit: from excl. pressure reducing valve
to excl. other system (excl. quench gas compressor)
RMC
Acid gas piping system
Limit: from excl. regeneration system
to excl. acid gas, incl. treatment system
RMD
Fluidizing gas piping system
Limit: from excl. main gas piping system
to excl. fluidizing air injection system or
to excl. load system (excl. fluidizing gas compressor)
RME
Airlock gas piping system (not inert gas)
Limit: from excl. branch off other system
to excl. airlocks (excl. airlock gas compressor)
RMF
Other gas piping system
Limit: from excl. branch off other system
to excl. other system
RMH
Storage system 1
Limit: from excl. store inlet
to excl. other gas piping system
RMJ
Storage system 2
Limit: from excl. store inlet
to excl. other gas piping system
RMM
Quench gas compressor system
Limit: from incl. compressor system inlet
to incl.
compressor system outlet
RMN
Expanded gas compressor system
Limit: from incl. compressor system inlet
to incl.
compressor system outlet
RMP
Acid gas compressor system
Limit: from incl. compressor system inlet
to incl.
compressor system outlet
RMQ
Fluidizing gas compressor system
Limit: from incl. compressor system inlet
to incl.
compressor system outlet
RMR
Airlock gas compressor system (not inert gas)
Limit: from incl. compressor system inlet
to incl.
compressor system outlet
RMS
Compressor system for other gases
Limit: from incl. compressor system inlet
to incl.
compressor system outlet
Printout date 14. Mrz. 01
Page RM1 of RM2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : RM
04.04.97
RMV
Lubricant supply system
RMW
Sealing fluid supply system
RMX
Fluid supply system for control and protection equipment
RMY
Control and protection equipment
RMZ
Injection and proportioning system
Printout date 14. Mrz. 01
Page RM2 of RM2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : RN
04.04.97
R
Gas generation and treatment
RN
Collection, storage and recycle systems for gas condensate
RNA
Collection, storage and recycle systems for gas condensate
RNB
Collection, storage and recycle systems for gas condensate
RNC
Collection, storage and recycle systems for gas condensate
RND
Collection, storage and recycle systems for gas condensate
RNE
Collection, storage and recycle systems for gas condensate
RNF
Collection, storage and recycle systems for gas condensate
RNG
Collection, storage and recycle systems for gas condensate
RNH
Collection, storage and recycle systems for gas condensate
RNJ
Collection, storage and recycle systems for gas condensate
RNK
Collection, storage and recycle systems for gas condensate
RNL
Collection, storage and recycle systems for gas condensate
RNM
Collection, storage and recycle systems for gas condensate
RNN
Collection, storage and recycle systems for gas condensate
RNP
Collection, storage and recycle systems for gas condensate
RNQ
Collection, storage and recycle systems for gas condensate
RNR
Collection, storage and recycle systems for gas condensate
RNS
Collection, storage and recycle systems for gas condensate
RNT
Collection, storage and recycle systems for gas condensate
RNU
Collection, storage and recycle systems for gas condensate
RNV
Lubricant supply system
RNW
Sealing fluid supply system
RNX
Fluid supply system for control and protection equipment
RNY
Control and protection equipment
Printout date 14. Mrz. 01
Page RN1 of RN1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : RP
04.04.97
R
Gas generation and treatment
RP
Inert gas, including recovery systems
RPA
Inert gas generation by air fractionation
Limit: from excl. atmosphere
to incl. inert gas distribution system inlet
RPB
Inert gas generation by molecular sieving
Limit: from excl. atmosphere
to incl. inert gas distribution system inlet
RPC
Inert gas generation by combustion
Limit: from excl. atmosphere
to incl. inert gas distribution system inlet
RPG
Nitrogen piping system for addition ahead of burner gas turbine
Limit: from excl. air separation plant outlet or
from excl. compressor outlet
to excl. compressor inlet or
to excl. combustion chamber inlet
RPH
Supercompression of nitrogen from *RPG*
Limit: from incl. compressor inlet
to incl.
compressor outlet
RPJ
Inert gas distribution system including storage system
Limit: from excl. inert gas generator outlet or
from excl. air separation plant *REF* outlet or
from excl. compressor outlet
to excl. compressor inlet or
to excl. inert gas load system inlet
RPK
Inert gas distribution system including storage system
Limit: from excl. inert gas generator outlet or
from excl. air separation plant *REF* outlet or
from excl. compressor outlet
to excl. compressor inlet or
to excl. inert gas load system inlet
RPL
Inert gas distribution system including storage system
Limit: from excl. inert gas generator outlet or
from excl. air separation plant *REF* outlet or
from excl. compressor outlet
to excl. compressor inlet or
to excl. inert gas load system inlet
RPM
Inert gas distribution system including storage system
Limit: from excl. inert gas generator outlet or
from excl. air separation plant *REF* outlet or
from excl. compressor outlet
to excl. compressor inlet or
to excl. inert gas load system inlet
RPN
Inert gas distribution system including storage system
Limit: from excl. inert gas generator outlet or
from excl. air separation plant *REF* outlet or
from excl. compressor outlet
to excl. compressor inlet or
to excl. inert gas load system inlet
Printout date 14. Mrz. 01
Page RP1 of RP2
Siemens
2 nd complete, non-project related edition
Condition-Date:
RPP
KKS
Identification System for Power
Plants
Function key : RP
04.04.97
Inert gas compressor system
Limit: from incl. compressor inlet
to incl.
compressor outlet
RPQ
Inert gas compressor system
Limit: from incl. compressor inlet
to incl.
compressor outlet
RPR
Inert gas compressor system
Limit: from incl. compressor inlet
to incl.
compressor outlet
RPS
Inert gas compressor system
Limit: from incl. compressor inlet
to incl.
compressor outlet
RPW
Sealing fluid supply system
RPX
Fluid supply system for control and protection equipment
RPY
Control and protection equipment
Printout date 14. Mrz. 01
Page RP2 of RP2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : RS
04.04.97
R
Gas generation and treatment
RS
Supply and removal systems for water, steam and condensate
RSA
Supply and removal systems for water, steam and condensate
Limit: The following applies to supply systems :
from excl. branch off other system
to excl. user
The following applies to removal systems :
from excl. producer
to excl. discharge into other system
RSB
Supply and removal systems for water, steam and condensate
Limit: The following applies to supply systems :
from excl. branch off other system
to excl. user
The following applies to removal systems :
from excl. producer
to excl. discharge into other system
RSC
Supply and removal systems for water, steam and condensate
Limit: The following applies to supply systems :
from excl. branch off other system
to excl. user
The following applies to removal systems :
from excl. producer
to excl. discharge into other system
RSD
Supply and removal systems for water, steam and condensate
Limit: The following applies to supply systems :
from excl. branch off other system
to excl. user
The following applies to removal systems :
from excl. producer
to excl. discharge into other system
RSE
Supply and removal systems for water, steam and condensate
Limit: The following applies to supply systems :
from excl. branch off other system
to excl. user
The following applies to removal systems :
from excl. producer
to excl. discharge into other system
RSF
Supply and removal systems for water, steam and condensate
Limit: The following applies to supply systems :
from excl. branch off other system
to excl. user
The following applies to removal systems :
from excl. producer
to excl. discharge into other system
RSG
Supply and removal systems for water, steam and condensate
Limit: The following applies to supply systems :
from excl. branch off other system
to excl. user
The following applies to removal systems :
from excl. producer
to excl. discharge into other system
Printout date 14. Mrz. 01
Page RS1 of RS3
Siemens
2 nd complete, non-project related edition
Condition-Date:
RSH
KKS
Identification System for Power
Plants
Function key : RS
04.04.97
Supply and removal systems for water, steam and condensate
Limit: The following applies to supply systems :
from excl. branch off other system
to excl. user
The following applies to removal systems :
from excl. producer
to excl. discharge into other system
RSJ
Supply and removal systems for water, steam and condensate
Limit: The following applies to supply systems :
from excl. branch off other system
to excl. user
The following applies to removal systems :
from excl. producer
to excl. discharge into other system
RSK
Supply and removal systems for water, steam and condensate
Limit: The following applies to supply systems :
from excl. branch off other system
to excl. user
The following applies to removal systems :
from excl. producer
to excl. discharge into other system
RSL
Supply and removal systems for water, steam and condensate
Limit: The following applies to supply systems :
from excl. branch off other system
to excl. user
The following applies to removal systems :
from excl. producer
to excl. discharge into other system
RSM
Supply and removal systems for water, steam and condensate
Limit: The following applies to supply systems :
from excl. branch off other system
to excl. user
The following applies to removal systems :
from excl. producer
to excl. discharge into other system
RSN
Supply and removal systems for water, steam and condensate
Limit: The following applies to supply systems :
from excl. branch off other system
to excl. user
The following applies to removal systems :
from excl. producer
to excl. discharge into other system
RSP
Supply and removal systems for water, steam and condensate
Limit: The following applies to supply systems :
from excl. branch off other system
to excl. user
The following applies to removal systems :
from excl. producer
to excl. discharge into other system
Printout date 14. Mrz. 01
Page RS2 of RS3
Siemens
2 nd complete, non-project related edition
Condition-Date:
RSQ
KKS
Identification System for Power
Plants
Function key : RS
04.04.97
Supply and removal systems for water, steam and condensate
Limit: The following applies to supply systems :
from excl. branch off other system
to excl. user
The following applies to removal systems :
from excl. producer
to excl. discharge into other system
RSR
Supply and removal systems for water, steam and condensate
Limit: The following applies to supply systems :
from excl. branch off other system
to excl. user
The following applies to removal systems :
from excl. producer
to excl. discharge into other system
RSS
Supply and removal systems for water, steam and condensate
Limit: The following applies to supply systems :
from excl. branch off other system
to excl. user
The following applies to removal systems :
from excl. producer
to excl. discharge into other system
RST
Supply and removal systems for water, steam and condensate
Limit: The following applies to supply systems :
from excl. branch off other system
to excl. user
The following applies to removal systems :
from excl. producer
to excl. discharge into other system
RSU
Supply and removal systems for water, steam and condensate
Limit: The following applies to supply systems :
from excl. branch off other system
to excl. user
The following applies to removal systems :
from excl. producer
to excl. discharge into other system
RSV
Lubricant supply system
RSW
Sealing fluid supply system
RSX
Fluid supply system for control and protection equipment
RSY
Control and protection equipment
RSZ
Injection and proportioning system
Printout date 14. Mrz. 01
Page RS3 of RS3
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : RT
04.04.97
R
Gas generation and treatment
RT
Waste water collection and drainage systems
RTA
Waste water collection and drainage systems
Limit: from excl. producer
to excl. discharge into other system
RTB
Waste water collection and drainage systems
Limit: from excl. producer
to excl. discharge into other system
RTC
Waste water collection and drainage systems
Limit: from excl. producer
to excl. discharge into other system
RTD
Waste water collection and drainage systems
Limit: from excl. producer
to excl. discharge into other system
RTE
Waste water collection and drainage systems
Limit: from excl. producer
to excl. discharge into other system
RTF
Waste water collection and drainage systems
Limit: from excl. producer
to excl. discharge into other system
RTG
Waste water collection and drainage systems
Limit: from excl. producer
to excl. discharge into other system
RTH
Waste water collection and drainage systems
Limit: from excl. producer
to excl. discharge into other system
RTJ
Waste water collection and drainage systems
Limit: from excl. producer
to excl. discharge into other system
RTK
Waste water collection and drainage systems
Limit: from excl. producer
to excl. discharge into other system
RTL
Waste water collection and drainage systems
Limit: from excl. producer
to excl. discharge into other system
RTM
Waste water collection and drainage systems
Limit: from excl. producer
to excl. discharge into other system
RTN
Waste water collection and drainage systems
Limit: from excl. producer
to excl. discharge into other system
RTP
Waste water collection and drainage systems
Limit: from excl. producer
to excl. discharge into other system
RTQ
Waste water collection and drainage systems
Limit: from excl. producer
to excl.
discharge into other system
Printout date 14. Mrz. 01
Page RT1 of RT2
Siemens
2 nd complete, non-project related edition
Condition-Date:
RTR
KKS
Identification System for Power
Plants
Function key : RT
04.04.97
Waste water collection and drainage systems
Limit: from excl. producer
to excl. discharge into other system
RTS
Waste water collection and drainage systems
Limit: from excl. producer
to excl. discharge into other system
RTT
Waste water collection and drainage systems
Limit: from excl. producer
to excl. discharge into other system
RTU
Waste water collection and drainage systems
Limit: from excl. producer
to excl. discharge into other system
RTV
Lubricant supply system
RTW
Sealing fluid supply system
RTX
Fluid supply system for control and protection equipment
RTY
Control and protection equipment
RTZ
Injection and proportioning system
Printout date 14. Mrz. 01
Page RT2 of RT2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : RU
04.04.97
R
Gas generation and treatment
RU
Waste water treatment systems
RUA
Waste water treatment system
Limit: from excl. inlet
to incl. outlet
RUB
Waste water treatment system
Limit: from excl. inlet
to incl. outlet
RUC
Waste water treatment system
Limit: from excl. inlet
to incl. outlet
RUD
Waste water treatment system
Limit: from excl. inlet
to incl. outlet
RUE
Waste water treatment system
Limit: from excl. inlet
to incl. outlet
RUF
Waste water treatment system
Limit: from excl. inlet
to incl. outlet
RUG
Waste water treatment system
Limit: from excl. inlet
to incl. outlet
RUJ
Processing material system
Limit: from incl. receiving point
to excl.
discharge
RUK
Processing material system
Limit: from incl. receiving point
to excl.
discharge
RUL
Processing material system
Limit: from incl. receiving point
to excl.
discharge
RUM
Waste water treatment system
Limit: from excl. inlet
to incl. outlet
RUN
Waste water treatment system
Limit: from excl. inlet
to incl. outlet
RUP
Waste water treatment system
Limit: from excl. inlet
to incl. outlet
RUQ
Waste water treatment system
Limit: from excl. inlet
to incl. outlet
RUR
Waste water treatment system
Limit: from excl. inlet
to incl. outlet
Printout date 14. Mrz. 01
Page RU1 of RU2
Siemens
2 nd complete, non-project related edition
Condition-Date:
RUS
KKS
Identification System for Power
Plants
Function key : RU
04.04.97
Residues treatment and removal system
Limit: from excl. receiving point
to excl. discharge
RUT
Residues treatment and removal system
Limit: from excl. receiving point
to excl. discharge
RUU
Residues treatment and removal system
Limit: from excl. receiving point
to excl. discharge
RUV
Lubricant supply system
RUW
Sealing fluid supply system
RUX
Fluid supply system for control and protection equipment
RUY
Control and protection equipment
RUZ
Injection and proportioning system
Printout date 14. Mrz. 01
Page RU2 of RU2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : RV
04.04.97
R
Gas generation and treatment
RV
Lubricant supply systems
RVA
Lubricant supply systems
RVB
Lubricant supply systems
RVC
Lubricant supply systems
RVD
Lubricant supply systems
RVE
Lubricant supply systems
RVF
Lubricant supply systems
RVG
Lubricant supply systems
RVH
Lubricant supply systems
RVJ
Lubricant supply systems
RVK
Lubricant supply systems
RVL
Lubricant supply systems
RVM
Lubricant supply systems
RVN
Lubricant supply systems
RVP
Lubricant supply systems
RVQ
Lubricant supply systems
RVR
Lubricant supply systems
RVS
Lubricant supply systems
RVT
Lubricant supply systems
RVU
Lubricant supply systems
Printout date 14. Mrz. 01
Page RV1 of RV1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : RW
04.04.97
R
Gas generation and treatment
RW
Sealing fluid supply systems
RWA
Sealing fluid supply systems
RWB
Sealing fluid supply systems
RWC
Sealing fluid supply systems
RWD
Sealing fluid supply systems
RWE
Sealing fluid supply systems
RWF
Sealing fluid supply systems
RWG
Sealing fluid supply systems
RWH
Sealing fluid supply systems
RWJ
Sealing fluid supply systems
RWK
Sealing fluid supply systems
RWL
Sealing fluid supply systems
RWM
Sealing fluid supply systems
RWN
Sealing fluid supply systems
RWP
Sealing fluid supply systems
RWQ
Sealing fluid supply systems
RWR
Sealing fluid supply systems
RWS
Sealing fluid supply systems
RWT
Sealing fluid supply systems
RWU
Sealing fluid supply systems
Printout date 14. Mrz. 01
Page RW1 of RW1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : RX
04.04.97
R
Gas generation and treatment
RX
Fluid supply systems for control and protection equipment
RXA
Fluid supply systems for control and protection equipment
RXB
Fluid supply systems for control and protection equipment
RXC
Fluid supply systems for control and protection equipment
RXD
Fluid supply systems for control and protection equipment
RXE
Fluid supply systems for control and protection equipment
RXF
Fluid supply systems for control and protection equipment
RXG
Fluid supply systems for control and protection equipment
RXH
Fluid supply systems for control and protection equipment
RXJ
Fluid supply systems for control and protection equipment
RXK
Fluid supply systems for control and protection equipment
RXL
Fluid supply systems for control and protection equipment
RXM
Fluid supply systems for control and protection equipment
RXN
Fluid supply systems for control and protection equipment
RXP
Fluid supply systems for control and protection equipment
RXQ
Fluid supply systems for control and protection equipment
RXR
Fluid supply systems for control and protection equipment
RXS
Fluid supply systems for control and protection equipment
RXT
Fluid supply systems for control and protection equipment
RXU
Fluid supply systems for control and protection equipment
Printout date 14. Mrz. 01
Page RX1 of RX1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : RY
04.04.97
R
Gas generation and treatment
RY
Control and protection equipment
RYA
Control and protection equipment
RYB
Control and protection equipment
RYC
Control and protection equipment
RYD
Control and protection equipment
RYE
Control and protection equipment
RYF
Control and protection equipment
RYG
Control and protection equipment
RYH
Control and protection equipment
RYJ
Control and protection equipment
RYK
Control and protection equipment
RYL
Control and protection equipment
RYM
Control and protection equipment
RYN
Control and protection equipment
RYP
Control and protection equipment
RYQ
Control and protection equipment
RYR
Control and protection equipment
RYS
Control and protection equipment
RYT
Control and protection equipment
RYU
Control and protection equipment
Printout date 14. Mrz. 01
Page RY1 of RY1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : RZ
04.04.97
R
Gas generation and treatment
RZ
Injection and proportioning systems
RZA
Injection and proportioning systems
RZB
Injection and proportioning systems
RZC
Injection and proportioning systems
RZD
Injection and proportioning systems
RZE
Injection and proportioning systems
RZF
Injection and proportioning systems
RZG
Injection and proportioning systems
RZH
Injection and proportioning systems
RZJ
Injection and proportioning systems
RZK
Injection and proportioning systems
RZL
Injection and proportioning systems
RZM
Injection and proportioning systems
RZN
Injection and proportioning systems
RZP
Injection and proportioning systems
RZQ
Injection and proportioning systems
RZR
Injection and proportioning systems
RZS
Injection and proportioning systems
RZT
Injection and proportioning systems
RZU
Injection and proportioning systems
Printout date 14. Mrz. 01
Page RZ1 of RZ1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : S
04.04.97
S
Ancillary systems
SA
Heating, ventilation, air-conditioning (HVAC) systems for conventional area
SB
Space heating systems
SC
Stationary compressed air supplies
SD
Stationary cleaning systems (see *FK.* for decontamination systems)
SE
Stationary welding gas systems
SF
Heating and fuel gas systems
SG
Stationary fire protection systems
SH
Waterway facilities
SM
Cranes, stationary hoists and conveying appliances
SN
Elevators
SP
Railway installations
SQ
Road installations
SR
Workshop, stores, laboratory equipment and staff amenities inside controlled area
ST
Workshop, stores, laboratory equipment and staff amenities outside controlled
area
Printout date 14. Mrz. 01
Page S1 of S1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : SA
04.04.97
S
Ancillary systems
SA
Heating, ventilation, air-conditioning (HVAC) systems for conventional area
SAA
Heating, ventilation, air-conditioning (HVAC) systems for conventional area
SAB
Heating, ventilation, air-conditioning (HVAC) systems for conventional area
SAC
Heating, ventilation, air-conditioning (HVAC) systems for conventional area
SAD
Heating, ventilation, air-conditioning (HVAC) systems for conventional area
SAE
Heating, ventilation, air-conditioning (HVAC) systems for conventional area
SAF
Heating, ventilation, air-conditioning (HVAC) systems for conventional area
SAG
Heating, ventilation, air-conditioning (HVAC) systems for conventional area
SAH
Heating, ventilation, air-conditioning (HVAC) systems for conventional area
SAJ
Heating, ventilation, air-conditioning (HVAC) systems for conventional area
SAK
Heating, ventilation, air-conditioning (HVAC) systems for conventional area
SAL
Heating, ventilation, air-conditioning (HVAC) systems for conventional area
SAM
Heating, ventilation, air-conditioning (HVAC) systems for conventional area
SAN
Heating, ventilation, air-conditioning (HVAC) systems for conventional area
SAP
Heating, ventilation, air-conditioning (HVAC) systems for conventional area
SAQ
Heating, ventilation, air-conditioning (HVAC) systems for conventional area
SAR
Heating, ventilation, air-conditioning (HVAC) systems for conventional area
SAS
Heating, ventilation, air-conditioning (HVAC) systems for conventional area
SAT
Heating, ventilation, air-conditioning (HVAC) systems for conventional area
SAU
Heating, ventilation, air-conditioning (HVAC) systems for conventional area
SAV
Lubricant supply system
SAX
Fluid supply system for control and protection equipment
SAY
Control and protection equipment
Printout date 14. Mrz. 01
Page SA1 of SA1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : SB
04.04.97
S
Ancillary systems
SB
Space heating systems
SBA
Space heating systems
SBB
Space heating systems
SBC
Space heating systems
SBD
Space heating systems
SBE
Space heating systems
SBF
Space heating systems
SBG
Space heating systems
SBH
Space heating systems
SBJ
Space heating systems
SBK
Space heating systems
SBL
Space heating systems
SBM
Space heating systems
SBN
Space heating systems
SBP
Space heating systems
SBQ
Space heating systems
SBR
Space heating systems
SBS
Space heating systems
SBT
Space heating systems
SBU
Space heating systems
SBX
Fluid supply system for control and protection equipment
SBY
Control and protection equipment
Printout date 14. Mrz. 01
Page SB1 of SB1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : SC
04.04.97
S
Ancillary systems
SC
Stationary compressed air supplies
SCA
Compressed air generation system
SCB
Compressed air distribution system
SCC
Stationary compressed air supplies
SCD
Stationary compressed air supplies
SCE
Stationary compressed air supplies
SCF
Stationary compressed air supplies
SCG
Stationary compressed air supplies
SCH
Stationary compressed air supplies
SCJ
Stationary compressed air supplies
SCK
Stationary compressed air supplies
SCL
Stationary compressed air supplies
SCM
Stationary compressed air supplies
SCN
Stationary compressed air supplies
SCP
Stationary compressed air supplies
SCQ
Stationary compressed air supplies
SCR
Stationary compressed air supplies
SCS
Stationary compressed air supplies
SCT
Stationary compressed air supplies
SCU
Stationary compressed air supplies
SCV
Lubricant supply system
SCX
Fluid supply system for control and protection equipment
SCY
Control and protection equipment
Printout date 14. Mrz. 01
Page SC1 of SC1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : SD
04.04.97
S
Ancillary systems
SD
Stationary cleaning systems (see *FK.* for decontamination systems)
SDA
Stationary cleaning systems
SDB
Stationary cleaning systems
SDC
Stationary cleaning systems
SDD
Stationary cleaning systems
SDE
Stationary cleaning systems
SDF
Stationary cleaning systems
SDG
Stationary cleaning systems
SDH
Stationary cleaning systems
SDJ
Stationary cleaning systems
SDK
Stationary cleaning systems
SDL
Stationary cleaning systems
SDM
Stationary cleaning systems
SDN
Stationary cleaning systems
SDP
Stationary cleaning systems
SDQ
Stationary cleaning systems
SDR
Stationary cleaning systems
SDS
Stationary cleaning systems
SDT
Stationary cleaning systems
SDU
Stationary cleaning systems
SDX
Fluid supply system for control and protection equipment
SDY
Control and protection equipment
Printout date 14. Mrz. 01
Page SD1 of SD1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : SE
04.04.97
S
Ancillary systems
SE
Stationary welding gas systems
SEA
Stationary welding gas systems
SEB
Stationary welding gas systems
SEC
Stationary welding gas systems
SED
Stationary welding gas systems
SEE
Stationary welding gas systems
SEF
Stationary welding gas systems
SEG
Stationary welding gas systems
SEH
Stationary welding gas systems
SEJ
Stationary welding gas systems
SEK
Stationary welding gas systems
SEL
Stationary welding gas systems
SEM
Stationary welding gas systems
SEN
Stationary welding gas systems
SEP
Stationary welding gas systems
SEQ
Stationary welding gas systems
SER
Stationary welding gas systems
SES
Stationary welding gas systems
SET
Stationary welding gas systems
SEU
Stationary welding gas systems
Printout date 14. Mrz. 01
Page SE1 of SE1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : SF
04.04.97
S
Ancillary systems
SF
Heating and fuel gas systems
SFA
Heating and fuel gas systems
SFB
Heating and fuel gas systems
SFC
Heating and fuel gas systems
SFD
Heating and fuel gas systems
SFE
Heating and fuel gas systems
SFF
Heating and fuel gas systems
SFG
Heating and fuel gas systems
SFH
Heating and fuel gas systems
SFJ
Heating and fuel gas systems
SFK
Heating and fuel gas systems
SFL
Heating and fuel gas systems
SFM
Heating and fuel gas systems
SFN
Heating and fuel gas systems
SFP
Heating and fuel gas systems
SFQ
Heating and fuel gas systems
SFR
Heating and fuel gas systems
SFS
Heating and fuel gas systems
SFT
Heating and fuel gas systems
SFU
Heating and fuel gas systems
SFY
Control and protection equipment
Printout date 14. Mrz. 01
Page SF1 of SF1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : SG
04.04.97
S
Ancillary systems
SG
Stationary fire protection systems
SGA
Fire water system, conventional area
SGB
Fire water system, nuclear area
SGC
Spray deluge systems, conventional area
SGD
Spray deluge systems, nuclear area
SGE
Sprinkler systems
SGF
Foam fire-fighting systems
SGG
Tank roof, tank shell cooling systems
SGJ
CO2 fire-fighting systems
SGK
Halon fire-fighting systems
SGL
Powder fire-fighting systems
SGM
Inergen fire-fighting systems
SGV
Lubricant supply system
SGX
Fluid supply system for control and protection equipment
SGY
Control and protection equipment
Printout date 14. Mrz. 01
Page SG1 of SG1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : SH
04.04.97
S
Ancillary systems
SH
Waterway facilities
SHA
Intake system (upper pound)
Limit: to excl.
lock chamber gate (upstream)
SHB
Lock chamber incl. chamber filling and emptying system
SHC
Lock chamber gate (upstream)
SHD
Lock chamber gate (intermediate)
SHE
Lock chamber gate (downstream)
SHF
Discharge system (lower pound)
Limit: from excl. lock chamber gate (downstream)
SHJ
Anti-icing system
SHK
Ship impact system
SHL
Leakage drain system
SHM
Draining system
SHS
Minimum water system
SHT
Fish ladder
SHU
Raft canal
SHV
Lubricant supply system
SHW
Sealing fluid supply system
SHX
Fluid supply system for control and protection equipment
SHY
Control and protection equipment
Printout date 14. Mrz. 01
Page SH1 of SH1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : SM
04.04.97
S
Ancillary systems
SM
Cranes, stationary hoists and conveying appliances
SMA
Cranes, stationary hoists and conveying appliances
SMB
Cranes, stationary hoists and conveying appliances
SMC
Cranes, stationary hoists and conveying appliances
SMD
Cranes, stationary hoists and conveying appliances
SME
Cranes, stationary hoists and conveying appliances
SMF
Cranes, stationary hoists and conveying appliances
SMG
Cranes, stationary hoists and conveying appliances
SMH
Cranes, stationary hoists and conveying appliances
SMJ
Cranes, stationary hoists and conveying appliances
SMK
Cranes, stationary hoists and conveying appliances
SML
Cranes, stationary hoists and conveying appliances
SMM
Cranes, stationary hoists and conveying appliances
SMN
Cranes, stationary hoists and conveying appliances
SMP
Cranes, stationary hoists and conveying appliances
SMQ
Cranes, stationary hoists and conveying appliances
SMR
Cranes, stationary hoists and conveying appliances
SMS
Cranes, stationary hoists and conveying appliances
SMT
Cranes, stationary hoists and conveying appliances
SMU
Cranes, stationary hoists and conveying appliances
SMX
Fluid supply system for control and protection equipment
SMY
Control and protection equipment
Printout date 14. Mrz. 01
Page SM1 of SM1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : SN
04.04.97
S
Ancillary systems
SN
Elevators
SNA
Elevators
SNB
Elevators
SNC
Elevators
SND
Elevators
SNE
Elevators
SNF
Elevators
SNG
Elevators
SNH
Elevators
SNJ
Elevators
SNK
Elevators
SNL
Elevators
SNM
Elevators
SNN
Elevators
SNP
Elevators
SNQ
Elevators
SNR
Elevators
SNS
Elevators
SNT
Elevators
SNU
Elevators
SNY
Control and protection equipment
Printout date 14. Mrz. 01
Page SN1 of SN1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : SP
04.04.97
S
Ancillary systems
SP
Railway installations
SPA
Railway installations
SPB
Railway installations
SPC
Railway installations
SPD
Railway installations
SPE
Railway installations
SPF
Railway installations
SPG
Railway installations
SPH
Railway installations
SPJ
Railway installations
SPK
Railway installations
SPL
Railway installations
SPM
Railway installations
SPN
Railway installations
SPP
Railway installations
SPQ
Railway installations
SPR
Railway installations
SPS
Railway installations
SPT
Railway installations
SPU
Railway installations
SPY
Control and protection equipment
Printout date 14. Mrz. 01
Page SP1 of SP1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : SQ
04.04.97
S
Ancillary systems
SQ
Road installations
SQA
Road installations
SQB
Road installations
SQC
Road installations
SQD
Road installations
SQE
Road installations
SQF
Road installations
SQG
Road installations
SQH
Road installations
SQJ
Road installations
SQK
Road installations
SQL
Road installations
SQM
Road installations
SQN
Road installations
SQP
Road installations
SQQ
Road installations
SQR
Road installations
SQS
Road installations
SQT
Road installations
SQU
Road installations
SQY
Control and protection equipment
Printout date 14. Mrz. 01
Page SQ1 of SQ1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : SR
04.04.97
S
Ancillary systems
SR
Workshop, stores, laboratory equipment and staff amenities inside controlled area
SRA
Hot workshop equipment
SRC
Maintenance areas in controlled area
SRG
Hot laboratory equipment
SRH
Health physics laboratory equipment
SRP
Staff amenities in controlled area
SRY
Control and protection equipment
Printout date 14. Mrz. 01
Page SR1 of SR1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : ST
04.04.97
S
Ancillary systems
ST
Workshop, stores, laboratory equipment and staff amenities outside controlled
area
STA
Workshop equipment outside controlled area
STC
Maintenance areas outside controlled area
STE
Stores and filling station equipment
STG
Laboratory equipment
STP
Staff amenities
STY
Control and protection equipment
Printout date 14. Mrz. 01
Page ST1 of ST1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : U
04.04.97
U
Structures
UA
Structures for grid and distribution systems
UB
Structures for power transmission and auxiliary power supply
UC
Structures for instrumentation and control
UE
Structures for conventional fuel supply and residues disposal
UF
Structures for the handling of nuclear equipment
UG
Structures for water supply and disposal
UH
Structures for conventional heat generation
UJ
Structures for nuclear heat generation
UK
Structures for reactor auxiliary systems
UL
Structures for steam-, water-, gas-cycles
UM
Structures for main machine sets
UN
Structures for process energy supply
UP
Structures for circulating (cooling) water systems (e. g. circulating water intake)
UQ
Structures for circulating (cooling) water systems (e. g. circulating water pumps
and outfall)
UR
Structures for circulating (cooling) water systems (e. g. recirculation cooling)
US
Structures for ancillary systems
UT
Structures for auxiliary systems
UU
Shaft structures
UV
Structures for chemical flue gas treatment incl. residues removal (for *HR.*,
*HS.*, *HT.*)
UX
Structures for external systems (power plant-specific)
UY
General service structures
UZ
Structures for transport, traffic, fencing, gardens and other purposes
Printout date 14. Mrz. 01
Page U1 of U1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : UA
04.04.97
U
Structures
UA
Structures for grid and distribution systems
UAA
Switchyard structure
UAB
Grid systems switchgear building
UAC
Grid systems control building
UAE
Structure for pneumatic control system
UAG
Structure for transformers
UAH
Structure for supports and equipment
UAX
Special structure (plant-specific)
UAY
Bridge structure
UAZ
Ducting structure
Printout date 14. Mrz. 01
Page UA1 of UA1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : UB
04.04.97
U
Structures
UB
Structures for power transmission and auxiliary power supply
UBA
Switchgear building
UBC
Structure for offsite system transformers
UBD
Structure for low-voltage auxiliary power transformers
UBE
Structure for medium-voltage auxiliary power transformers
UBF
Structure for generator transformers
UBG
Structure for start-up transformers
UBH
Structure for oil collecting pits
UBJ
Structure for transformer tracks
UBK
Transformer assembly building
UBL
Structure for busbars
UBM
Structure for transformer cooling systems
UBN
Structure for emergency power generating sets (without central water chiller)
UBP
Emergency power generating and central water chiller building
UBQ
Structure for emergency power generator fuel supply system
UBX
Special structure (plant-specific)
UBY
Bridge structure
UBZ
Ducting structure
Printout date 14. Mrz. 01
Page UB1 of UB1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : UC
04.04.97
U
Structures
UC
Structures for instrumentation and control
UCA
Unit control room building
UCB
Control station building
UCL
Structure for measuring equipment
UCP
Cooling water monitoring structure
UCX
Special structure (plant-specific)
UCY
Bridge structure
UCZ
Ducting structure
Printout date 14. Mrz. 01
Page UC1 of UC1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : UE
04.04.97
U
Structures
UE
Structures for conventional fuel supply and residues disposal
UEA
Structure for unloading of solid fuels
UEB
Structure for storage of solid fuels
UED
Structure for transport of solid fuels
UEE
Structure for treatment of solid fuels
UEF
Structure for transfer (e. g. junction tower)
UEG
Structure for conversion of solid fuels
UEH
Structure for unloading and reception of liquid fuels
UEJ
Structure for storage of liquid fuels
UEL
Structure for forwarding of liquid fuels (e. g. pump house)
UEM
Structure for treatment and handling of liquid fuels
UEN
Structure for transfer, conversion, storage of gaseous fuels
UER
Structure for forwarding of gaseous fuels
UET
Structure for ash storage
UEU
Structure for ash transport
UEV
Structure for ash settling pond
UEW
Structure for combustion residues handling
UEX
Special structure (plant-specific)
UEY
Bridge structure
UEZ
Ducting structure
Printout date 14. Mrz. 01
Page UE1 of UE1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : UF
04.04.97
U
Structures
UF
Structures for the handling of nuclear equipment
UFA
Fuel pool building
UFB
Fuel handling building
UFC
Fuel storage building
UFJ
Structure for hot cell
UFX
Special structure (plant-specific)
UFY
Bridge structure
UFZ
Ducting structure
Printout date 14. Mrz. 01
Page UF1 of UF1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : UG
04.04.97
U
Structures
UG
Structures for water supply and disposal
UGA
Structure for raw water supply
UGD
Structure for demineralization system
UGE
Structure for neutralization system
UGF
Structure for fire water supply
UGG
Structure for drinking water supply
UGH
Structure for rainwater
UGJ
Structure for cooling tower make-up water treatment
UGK
Flocculant mixing chamber
UGL
Flocculator structure, flocculator
UGN
Treated water basin
UGP
Sludge thickener
UGQ
Sludge dewatering building
UGR
Sludge storage structure
UGU
Structure for effluent disposal
UGV
Structure for sewerage plant
UGX
Special structure (plant-specific)
UGY
Bridge structure
UGZ
Ducting structure
Printout date 14. Mrz. 01
Page UG1 of UG1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : UH
04.04.97
U
Structures
UH
Structures for conventional heat generation
UHA
Steam generator enclosure, steam generator building (boiler house)
UHF
Bunker bay
UHL
Structure for boiler compressed air supply
UHN
Smoke stack, incl. structure for flue gas circulation (e. g. for induced draft fan)
UHQ
Structure for flue gas filtering system
UHU
Structure for flue gas reheating system
UHV
Structure for combustion air circulation (e. g. for forced draft fan)
UHW
Boiler blowdown structure
UHX
Special structure (plant-specific)
UHY
Bridge structure
UHZ
Ducting structure
Printout date 14. Mrz. 01
Page UH1 of UH1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : UJ
04.04.97
U
Structures
UJ
Structures for nuclear heat generation
UJA
Reactor building, containment interior (when separate from *UJB*)
UJB
Reactor building annulus (when separate from *UJA*)
UJC
Heat exchanger building (not for light water reactors)
UJD
Steam generator building (not for light water reactors)
UJE
Main steam and feedwater valve compartment
UJF
Equipment air lock enclosure
UJG
Gantry (reactor building)
UJX
Special structure (plant-specific)
UJY
Bridge structure
UJZ
Ducting structure
Printout date 14. Mrz. 01
Page UJ1 of UJ1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : UK
04.04.97
U
Structures
UK
Structures for reactor auxiliary systems
UKA
Reactor auxiliary building
UKB
Reactor ancillary systems building (e. g. for BWR plants)
UKC
Nuclear services building (not for light water reactors)
UKD
Emergency standby structure (not for light water reactors)
UKH
Structure for air exhaust (vent stack)
UKJ
Tritium extraction system building
UKS
Radioactive waste processing building
UKT
Structure for radioactive waste storage
UKX
Special structure (plant-specific)
UKY
Bridge structure
UKZ
Ducting structure
Printout date 14. Mrz. 01
Page UK1 of UK1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : UL
04.04.97
U
Structures
UL
Structures for steam-, water-, gas-cycles
ULA
Feedwater pump house
ULB
Emergency feed building
ULC
Structure for condensate system
ULD
Structure for condensate polishing plant (if separate)
ULE
Structure for emergency supply systems (if separate)
ULN
Structure for hydroelectric power plant water impounding works
ULP
Structure for hydroelectric power plant intake systems
ULQ
Structure for hydroelectric power plant tail-race systems
ULX
Special structure (plant-specific)
ULY
Bridge structure
ULZ
Ducting structure
Printout date 14. Mrz. 01
Page UL1 of UL1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : UM
04.04.97
U
Structures
UM
Structures for main machine sets
UMA
Steam turbine building
UMB
Gas turbine building
UMC
Gas and steam turbine building (tandem arrangement)
UME
Hydraulic turbine building
UMG
Pumped storage turbine building
UMJ
Diesel engine building
UMM
Compressor system building
UMR
Gas engine plant building
UMX
Special structure (plant-specific)
UMY
Bridge structure
UMZ
Ducting structure
Printout date 14. Mrz. 01
Page UM1 of UM1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : UN
04.04.97
U
Structures
UN
Structures for process energy supply
UNX
Special structure (plant-specific)
UNY
Bridge structure
UNZ
Ducting structure
Printout date 14. Mrz. 01
Page UN1 of UN1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : UP
04.04.97
U
Structures
UP
Structures for circulating (cooling) water systems (e. g. circulating water intake)
UPA
Circulating (cooling) water intake culvert
UPB
Service (secondary cooling) water intake culvert
UPC
Circulating (cooling) water intake structure
UPD
Service (secondary cooling) water intake structure
UPH
Circulating (cooling) water treatment structure
UPJ
Service (secondary cooling) water treatment structure
UPN
Circulating (cooling) water inlet culvert
UPP
Service (secondary cooling) water inlet culvert
UPQ
Biocide treatment building
UPS
Debris trough
UPT
Screen wash water cleaning structure
UPX
Special structure (plant-specific)
UPY
Bridge structure
UPZ
Ducting structure
Printout date 14. Mrz. 01
Page UP1 of UP1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : UQ
04.04.97
U
Structures
UQ
Structures for circulating (cooling) water systems (e. g. circulating water pumps
and outfall)
UQA
Circulating (cooling) water pump building
UQB
Service (secondary cooling) water pump building
UQG
Circulating (cooling) water overflow structure, surge tank
UQH
Screen wash water discharge culvert
UQJ
Circulating (cooling) water seal pit, incl. circulating (cooling) water aeration
structure
UQK
Circulating (cooling) water venting structure
UQL
Service (secondary cooling) water surge pond
UQM
Service (secondary cooling) water collecting pond
UQN
Circulating (cooling) water outfall culvert
UQP
Service (secondary cooling) water outfall culvert
UQQ
Circulating (cooling) water outfall structure
UQR
Service (secondary cooling) water outfall structure
UQS
Circulating (cooling) water discharge culvert
UQT
Service (secondary cooling) water discharge culvert
UQU
Circulating (cooling) water spillway structure, incl. circulating (cooling) water
aeration structure
UQV
Structure for artificial circulating (cooling) water aeration
UQW
Routing structure for circulating (cooling) water discharge
UQX
Special structure (plant-specific)
UQY
Bridge structure
UQZ
Ducting structure
Printout date 14. Mrz. 01
Page UQ1 of UQ1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : UR
04.04.97
U
Structures
UR
Structures for circulating (cooling) water systems (e. g. recirculation cooling)
URA
Cooling tower structure (circulating/main cooling water)
URB
Cooling tower structure (service/secondary cooling water)
URD
Cooling tower pump building (circulating/main cooling water)
URE
Cooling tower pump building (service/secondary cooling water)
URG
Cooling tower connecting structure
URH
Cooling tower outlet structure
URJ
Cooling tower outfall culvert
URK
Cooling tower return structure
URL
Cooling tower return culvert
URM
Circulating (cooling) water distribution building
URN
Cooling tower bypass structure
URP
Cooling tower blowdown structure
URQ
Cooling tower blowdown culvert
URX
Special structure (plant-specific)
URY
Bridge structure
URZ
Ducting structure
Printout date 14. Mrz. 01
Page UR1 of UR1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : US
04.04.97
U
Structures
US
Structures for ancillary systems
USA
Structure for heating, ventilation, air-conditioning (HVAC) systems
USB
Structure for space heating systems
USC
Structure for stationary compressed air supply system
USG
Fire pump house
USH
Structure for waterway facilities
USR
Structure for conventional waste treatment
UST
Workshop and stores building
USU
Consumables storage building
USV
Laboratory building
USX
Special structure (plant-specific)
USY
Bridge structure
USZ
Ducting structure
Printout date 14. Mrz. 01
Page US1 of US1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : UT
04.04.97
U
Structures
UT
Structures for auxiliary systems
UTA
Supply systems building
UTB
Central water chiller building, conventional area
UTC
Central water chiller building, nuclear area
UTF
Compressed air system building
UTG
Central gas supply systems building (no fuel supply)
UTH
Auxiliary steam generator building
UTJ
Smoke stack
UTS
Chemical storage tank pit
UTX
Special structure (plant-specific)
UTY
Bridge structure
UTZ
Ducting structure
Printout date 14. Mrz. 01
Page UT1 of UT1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : UU
04.04.97
U
Structures
UU
Shaft structures
Printout date 14. Mrz. 01
Page UU1 of UU1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : UV
04.04.97
U
Structures
UV
Structures for chemical flue gas treatment incl. residues removal (for *HR.*,
*HS.*, *HT.*)
UVA
Structure for flue gas-side heat exchanger
UVB
Structure for flue gas fan system
UVC
Structure for flue gas scrubber, reactor
UVD
Structure for adsorbent/absorbent circuit
UVE
Structure for reagent supply, incl. preparation/treatment, storage, forwarding
UVF
Structure for thickening and solids dewatering, solids drying and compacting
system
UVG
Structure for chemical flue gas treatment
UVH
Structure for (solids/product) forwarding, storage, loading
UVM
Structure for catalyst handling and storage
UVX
Special structure (plant-specific)
UVY
Bridge structure
UVZ
Ducting structure
Printout date 14. Mrz. 01
Page UV1 of UV1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : UX
04.04.97
U
Structures
UX
Structures for external systems (power plant-specific)
UXA
Structure for seawater desalination plant
UXX
Special structure (plant-specific)
UXY
Bridge structure
UXZ
Ducting structure
Printout date 14. Mrz. 01
Page UX1 of UX1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : UY
04.04.97
U
Structures
UY
General service structures
UYA
Office and staff amenities building
UYB
Staff amenities building
UYC
Administration building
UYD
Canteen
UYE
Gate house
UYF
Security gate house
UYG
Information center
UYH
Training facilities
UYJ
Medical center
UYN
Railway engine shed
UYP
Fire station
UYQ
Garage
UYR
Automobile workshop
UYS
Filling station
UYX
Special structure (plant-specific)
UYY
Bridge structure
UYZ
Ducting structure
Printout date 14. Mrz. 01
Page UY1 of UY1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : UZ
04.04.97
U
Structures
UZ
Structures for transport, traffic, fencing, gardens and other purposes
UZA
Works roadways, paths, incl. associated structures
UZC
Yards
UZD
Parking areas, incl. associated structures
UZE
Railway structures
UZF
Lifting gear structures
UZJ
Fencing and gates
UZK
Gardens, incl. structures
UZL
Noise abatement structures
UZM
Protective structures against external impact (EI)
UZN
Structure for flood protection
UZP
Structure for bank/shoreline stabilization
UZQ
Structure for river regulation
UZR
Jetty, quay
UZS
Breakwaters
UZT
Outdoor area, plots of land and land rights
UZU
Site security structure
UZW
Residential buildings, residential area
UZX
Special structure (plant-specific), scrap yard
UZY
Bridge structure
UZZ
Ducting structure
Printout date 14. Mrz. 01
Page UZ1 of UZ1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : W
04.04.97
W
Renewable energy plants
WA
Solar system (for coordinates)
WB
Solar system (for coordinates)
WC
Solar system (for coordinates)
WD
Solar system (for coordinates)
WE
Solar system (for coordinates)
WF
Solar system (for coordinates)
WG
Solar system (for coordinates)
WH
Solar system (for coordinates)
WJ
Solar system (for coordinates)
WK
Solar system (for coordinates)
WL
Solar system (for coordinates)
WM
Solar system (for coordinates)
WN
Solar system (for coordinates)
WP
Solar system (for coordinates)
WQ
Solar system (for coordinates)
WR
Solar system (for coordinates)
WS
Solar system (for coordinates)
WT
Solar heating system
WV
Lubricant supply system
WW
Sealing fluid supply system
WX
Fluid supply system for control and protection equipment
WY
Control and protection equipment
Printout date 14. Mrz. 01
Page W1 of W1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : WT
04.04.97
W
Renewable energy plants
WT
Solar heating system
WTA
Solar heating system
WTB
Solar heating system
WTC
Solar heating system
WTD
Solar heating system
WTE
Solar heating system
WTF
Solar heating system
WTG
Solar heating system
WTH
Solar heating system
WTJ
Solar heating system
WTK
Solar heating system
WTL
Solar heating system
WTM
Solar heating system
WTN
Solar heating system
WTP
Solar heating system
WTQ
Solar heating system
WTR
Solar heating system
WTS
Solar heating system
WTT
Solar heating system
WTU
Solar heating system
WTX
Fluid supply system for control and protection equipment
WTY
Control and protection equipment
Printout date 14. Mrz. 01
Page WT1 of WT1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : WV
04.04.97
W
Renewable energy plants
WV
Lubricant supply system
WVA
Lubricant supply system
WVB
Lubricant supply system
WVC
Lubricant supply system
WVD
Lubricant supply system
WVE
Lubricant supply system
WVF
Lubricant supply system
WVG
Lubricant supply system
WVH
Lubricant supply system
WVJ
Lubricant supply system
WVK
Lubricant supply system
WVL
Lubricant supply system
WVM
Lubricant supply system
WVN
Lubricant supply system
WVP
Lubricant supply system
WVQ
Lubricant supply system
WVR
Lubricant supply system
WVS
Lubricant supply system
WVT
Lubricant supply system
WVU
Lubricant supply system
Printout date 14. Mrz. 01
Page WV1 of WV1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : WW
04.04.97
W
Renewable energy plants
WW
Sealing fluid supply system
WWA
Sealing fluid supply system
WWB
Sealing fluid supply system
WWC
Sealing fluid supply system
WWD
Sealing fluid supply system
WWE
Sealing fluid supply system
WWF
Sealing fluid supply system
WWG
Sealing fluid supply system
WWH
Sealing fluid supply system
WWJ
Sealing fluid supply system
WWK
Sealing fluid supply system
WWL
Sealing fluid supply system
WWM
Sealing fluid supply system
WWN
Sealing fluid supply system
WWP
Sealing fluid supply system
WWQ
Sealing fluid supply system
WWR
Sealing fluid supply system
WWS
Sealing fluid supply system
WWT
Sealing fluid supply system
WWU
Sealing fluid supply system
Printout date 14. Mrz. 01
Page WW1 of WW1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : WX
04.04.97
W
Renewable energy plants
WX
Fluid supply system for control and protection equipment
WXA
Fluid supply system for control and protection equipment
WXB
Fluid supply system for control and protection equipment
WXC
Fluid supply system for control and protection equipment
WXD
Fluid supply system for control and protection equipment
WXE
Fluid supply system for control and protection equipment
WXF
Fluid supply system for control and protection equipment
WXG
Fluid supply system for control and protection equipment
WXH
Fluid supply system for control and protection equipment
WXJ
Fluid supply system for control and protection equipment
WXK
Fluid supply system for control and protection equipment
WXL
Fluid supply system for control and protection equipment
WXM
Fluid supply system for control and protection equipment
WXN
Fluid supply system for control and protection equipment
WXP
Fluid supply system for control and protection equipment
WXQ
Fluid supply system for control and protection equipment
WXR
Fluid supply system for control and protection equipment
WXS
Fluid supply system for control and protection equipment
WXT
Fluid supply system for control and protection equipment
WXU
Fluid supply system for control and protection equipment
Printout date 14. Mrz. 01
Page WX1 of WX1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : WY
04.04.97
W
Renewable energy plants
WY
Control and protection equipment
WYA
Control and protection equipment
WYB
Control and protection equipment
WYC
Control and protection equipment
WYD
Control and protection equipment
WYE
Control and protection equipment
WYF
Control and protection equipment
WYG
Control and protection equipment
WYH
Control and protection equipment
WYJ
Control and protection equipment
WYK
Control and protection equipment
WYL
Control and protection equipment
WYM
Control and protection equipment
WYN
Control and protection equipment
WYP
Control and protection equipment
WYQ
Control and protection equipment
WYR
Control and protection equipment
WYS
Control and protection equipment
WYT
Control and protection equipment
WYU
Control and protection equipment
Printout date 14. Mrz. 01
Page WY1 of WY1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : X
04.04.97
X
Heavy machinery (not main machine sets)
XA
Steam turbuine plant
XB
Gas turbine plant
XE
Hydraulic turbine plant
XG
Pumped-storage plant
XJ
Diesel engine plant
XK
Generator plant
XL
Electro-motive plant (incl. motor generator)
XP
Common installations for heavy machinery
XR
Gas engine plant
XV
Lubricant supply system
XW
Sealing fluid supply system
XX
Fluid supply system for control and protection equipment
XY
Control and protection equipment
Printout date 14. Mrz. 01
a
Page X1 of X1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : XA
04.04.97
X
Heavy machinery (not main machine sets)
XA
Steam turbuine plant
XAA
HP turbine
Limit: from incl. steam admission (main stop valve) or combined
main stop and control valve
to incl.
automatic/non-automatic extraction and exhaust
nozzles and
to incl.
the interfaces with other turbine internal systems
XAB
IP turbine
Limit: from incl. crossover line, incl. control element or
from incl. intercept valve
to incl.
automatic/non-automatic extraction and exhaust
nozzles and
to incl.
the interfaces with other turbine internal systems
XAC
LP turbine
Limit: from incl. crossover line, incl. control element or
from incl. intercept valve or steam inlet nozzle
(in reheat system without intercept valve)
to incl.
automatic/non-automatic extraction and exhaust
nozzles and
to incl.
the interfaces with other turbine
XAD
Bearings
XAG
Condensing system
Limit: from incl. condenser neck or inlet nozzle
to incl.
condenser outlet nozzle, incl. connected flash
tanks, incl. instrumentation equipment associated
with condenser
XAH
Motive water system (if separate from *XAJ*)
Limit: from excl. outlet of other system
to excl. water-operated air ejector inlet
XAJ
Air removal system
Limit: from excl. condenser outlet
to excl. atmosphere
XAK
Transmission gear between prime mover and driven machine, incl. turning gear
XAL
Drain and vent systems
Limit: from incl. collector point or
from incl. final drain
to excl.
discharge into other system
XAM
Leak-off steam system
Limit: from excl. branch from seal leak-off
to excl. discharge into other system
XAN
Turbine bypass station, incl. desuperheating spray system
Limit: from incl. bypass valve and
from incl. desuperheating spray valve
to incl.
steam inlet to condenser
XAP
LP turbine bypass
Limit: from excl. bypass valve and
from excl. branch off steam system
to excl. condenser
Printout date 14. Mrz. 01
Page XA1 of XA2
Siemens
2 nd complete, non-project related edition
Condition-Date:
XAQ
KKS
Identification System for Power
Plants
Function key : XA
04.04.97
Vent system (if separate from *XAL*)
Limit: from incl. venting point
to excl.
discharge into other system
XAV
Lubricant supply system
Limit: from incl. dedicated lubricant tank or common lubricant
and control fluid tank or
from excl. branch off lubricant fluid supply system
to excl.
user and
from excl. user
XAW
Sealing, heating and cooling steam system
Limit: from excl. branch
to excl. casing nozzle of steam user and leak-off
to excl. condenser or
to incl. gland steam condenser or
to excl. heating/cooling steam user
XAX
Non-electric control and protection equipment, incl. fluid supply system
XAY
Electrical control and protection equipment
Printout date 14. Mrz. 01
Page XA2 of XA2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : XB
04.04.97
X
Heavy machinery (not main machine sets)
XB
Gas turbine plant
XBA
Turbine, compressor rotor with common casing
Limit: from incl. compressor inlet
to incl.
compressor outlet
from incl. turbine inlet
to incl.
turbine outlet, incl. exhaust gas diffuser
XBB
Turbine casing and rotor
Limit: from incl. turbine inlet
to incl.
turbine outlet, incl. exhaust gas diffuser
XBC
Compressor casing and rotor
Limit: from incl. compressor inlet
to incl.
compressor outlet
XBD
Bearings
XBH
Cooling and sealing gas system
Limit: from incl. extraction point
to excl.
user and
from excl. user, incl. leak-off
to incl.
inlet to other system
XBJ
Start-up unit
XBK
Transmission gear between prime mover and driven machine, incl. turning gear,
barring gear
XBL
Intake air, cold gas system (open cycle)
Limit: from excl. atmosphere
to excl. combustion chamber or
to excl. compressor inlet or
to incl. exhaust gas heat exchanger, excl. compressor
XBM
Combustion chamber (gas heating, combustion)
Limit: from incl. cold gas, fuel inlet
to incl.
hot gas outlet
XBN
Fuel supply system (liquid)
Limit: from excl. branch off main supply line or
from incl. temporary (day) tank
to excl. combustion chamber or
to excl. motive gas generating unit, incl. fuel return system
XBP
Fuel supply system (gaseous)
Limit: from excl. branch off main supply line
to excl. combustion chamber or
to excl. motive gas generating unit
XBQ
Ignition fuel supply system (if separate)
Limit: from excl. branch off main supply line or
from incl. storage tank
to excl. combustion chamber or
to excl. motive gas generating unit
XBR
Exhaust gas system (open cycle)
Limit: from excl. combustion chamber or
from excl. exhaust gas diffuser
to excl. discharge into atmosphere, excl. turbine, or
to excl. inlet to other system (e. g. combustion air system)
Printout date 14. Mrz. 01
Page XB1 of XB2
Siemens
2 nd complete, non-project related edition
Condition-Date:
XBS
KKS
Identification System for Power
Plants
Function key : XB
04.04.97
Storage system
Limit: to excl.
connection to main system and
from excl. connection to main system
XBT
Motive gas generator unit, incl. combustion chamber
Limit: from incl. air/fuel inlet
to incl.
motive gas outlet of motive gas generating unit
XBU
Additive system
Limit: from incl. supply
to incl.
injection
XBV
Lubricant supply system
Limit: from incl. dedicated lubricant tank or common lubricant
and control fluid tank or
from excl. branch off control fluid supply system
to excl.
user and
from excl. user
XBW
Seal oil supply
Limit: from incl. dedicated sealing oil tank or
from excl. sealing oil pump suction line
to excl.
user and
from excl. user
XBX
Non-electric control and protection equipment, incl. fluid supply system
XBY
Electrical control and protection equipment
XBZ
Lubricant and control fluid treatment system
Printout date 14. Mrz. 01
Page XB2 of XB2
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : XE
04.04.97
X
Heavy machinery (not main machine sets)
XE
Hydraulic turbine plant
XEA
Turbine (casing, shaft, runner, draft tube etc.)
Limit: from excl. turbine inlet or
from excl. isolating valve
to incl. turbine outlet or
to excl. isolating valve
XEB
Isolating valve
Task: to isolate headwater from turbine *XEA* and/or
to control headwater flow to turbine *XEA*
XED
Bearings
XEG
Stabilizing air system
Limit: from incl. air compressor
to incl.
outlet to turbine
XEK
Transmission gear between prime mover and driven machine
XEL
Water depression air supply system
Limit: from incl. air compressor
to incl.
outlet to turbine
XES
Shaft gland cooling water system
XEV
Lubricant supply system
Limit: from incl. lubricant tank
to excl.
user and
from excl. user
XEW
Sealing water supply system
Limit: from incl. sealing water supply main isolating valve
to excl.
casing nozzle of sealing water user
XEX
Non-electric control and protection equipment, incl. fluid supply system
XEY
Electrical control and protection equipment
Printout date 14. Mrz. 01
Page XE1 of XE1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : XG
31.07.98
X
Heavy machinery (not main machine sets)
XG
Pumped-storage plant
a
XGA
Storage pump (casing, shaft, runner etc.)
a
Limit: from excl. storage pump inlet or
from excl. isolating valve
to incl. storage pump outlet or
to excl. isolating valve
XGB
Isolating valve
a
Task: to isolate water from storage pump *XGA* and/or
to control water flow to storage pump *XGA*
XGD
Bearings
a
XGK
Transmission gear between motor generator set and storage pump
a
XGL
Water depression air supply system
a
Limit: from incl. air compressor
to incl.
inlet to storage pump
XGM
Start-up unit
a
XGS
Shaft gland cooling water system
a
XGV
Lubricant supply system
a
Limit: from incl. lubricant tank
to excl.
user and
from excl. user
XGW
Sealing water supply system
a
Limit: from incl. sealing water supply main isolating valve
to excl.
casing nozzle of sealing water user
XGX
Non-electric control and protection equipment, incl. fluid supply system
a
XGY
Electrical control and protection equipment
a
Printout date 19. Mrz. 01
Page XG1 of XG1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : XJ
04.04.97
X
Heavy machinery (not main machine sets)
XJ
Diesel engine plant
XJA
Engine
Limit: from incl. fuel injection nozzle inlet or
from incl. air intake nozzles or
from incl. cooling water inlet nozzles
to incl.
exhaust nozzle outlet or
to incl.
cooling water nozzle outlet,
incl. engine-internal systems
XJB
Turbocharger, blower
Limit: from incl. turbocharger or blower inlet
to incl.
turbocharger or blower outlet
XJG
Liquid cooling system
Limit: from excl. engine cooling water nozzle outlet or
from incl. turbocharger air cooling system inlet
to excl. engine cooling water nozzle inlet or
to incl. turbocharger air cooler outlet
XJH
Air intercooling system
Limit: from incl. intercooler inlet
to incl.
intercooler outlet
to excl.
outlet to other cooling systems
XJK
Transmission gear between prime mover and driven machine
XJN
Fuel systems
Limit: from incl. temporary (day) tank or
from excl. branch off piping system
to excl.
fuel injection nozzle inlet
XJP
Start-up unit, (incl. flywheel)
XJQ
Air intake system
Limit: from excl. atmosphere
to excl. turbocharger or
to excl. engine air intake nozzles
XJR
Exhaust gas system
Limit: from excl. engine exhaust nozzle outlet
to excl. discharge to atmosphere
XJV
Lubricant supply system
Limit: from incl. dedicated lubricant tank or common lubricant
and control fluid tank or
from excl. branch off control fluid supply system
to excl.
user and
from excl. user
XJW
Sealing fluid supply system
XJX
Fluid supply system for control and protection equipment
XJY
Control and protection equipment
Printout date 14. Mrz. 01
Page XJ1 of XJ1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : XK
04.04.97
X
Heavy machinery (not main machine sets)
XK
Generator plant
XKA
Generator frame, incl. stator, rotor and all integral cooling equipment
Limit: to incl.
generator bushing
XKB
Generator exciter set, including set with electrical braking system (use only if
*XKC* is not sufficient for identification)
XKC
Generator exciter set, including set with electrical braking system
XKD
Bearings
XKF
Stator/rotor liquid cooling system, incl. coolant supply system
Hint: for cooling oil see *XKU*
Limit: from excl. stator/rotor outlet
to excl. stator/rotor inlet
Task: dissipate heat produced by stator/rotor to liquid coolant
XKG
Stator/rotor hydrogen (H2) cooling system, incl. coolant supply system
a
Hint: for nitrogen / carbon dioxyde cooling see *XKH*
Limit: from excl. stator/rotor outlet
to excl. stator/rotor inlet
Task: dissipate heat produced by stator/rotor to hydrogen coolant
XKH
Stator/rotor nitrogen (N2) / carbon dioxyde (CO2) cooling system, incl. coolant
supply system
a
Hint: for other gas cooling see *XKG*
Limit: from excl. stator/rotor outlet
to excl. stator/rotor inlet
Task: dissipate heat produced by stator/rotor to nitrogen / carbon
dioxyde coolant
XKJ
Stator/rotor air cooling system, incl. coolant supply system
Hint: for other gas cooling see *XKG* and *XKH*
Limit: from excl. stator/rotor outlet
to excl. stator/rotor inlet
Task: dissipate heat produced by stator/rotor to air coolant
XKQ
Exhaust gas system (if separate from *XKG* and *XKH*)
XKU
Stator/rotor cooling oil cooling system, incl. coolant supply system
Hint: for other liquid cooling see *XKF*
Limit: from excl. stator/rotor outlet
to excl. stator/rotor inlet
Task: dissipate heat produced by stator/rotor to cooling oil
coolant
XKV
Lubricant supply system (if separate system for generator)
XKW
Sealing oil system, incl. supply and treatment
Limit: from excl. branch off sealing oil supply system
to excl. stator inlet and
from excl. stator outlet
to excl. inlet to other system or in closed systems
from excl. stator outlet
to excl. stator inlet
XKX
Fluid supply system for control and protection equipment
XKY
Control and protection equipment
Printout date 14. Mrz. 01
Page XK1 of XK1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : XL
04.04.97
X
Heavy machinery (not main machine sets)
XL
Electro-motive plant (incl. motor generator)
XLA
Motor frame, motor generator frame, incl. stator, rotor and all integral cooling
equipment
Limit: to incl.
motor or generator bushing
XLC
Exciter set
XLD
Bearings
XLF
Stator/rotor liquid cooling system, incl. coolant supply system
Hint: for cooling oil see *XLU*
Limit: from excl. stator/rotor outlet
to excl. stator/rotor inlet
Task: dissipate heat produced by stator/rotor to coolant
XLG
Stator/rotor gas cooling system, incl. coolant supply system
Hint: for nitrogen cooling see *XLH*
Limit: from excl. stator/rotor outlet
to excl. stator/rotor inlet
Task: dissipate heat produced by stator/rotor to coolant
XLH
Stator/rotor nitrogen cooling system, incl. coolant supply system
Hint: for other gas cooling see *XLG*
Limit: from excl. stator/rotor outlet
to excl. stator/rotor inlet
Task: dissipate heat produced by stator/rotor to coolant
XLQ
Exhaust gas system (if separate from *XLG* and *XLH*)
XLU
Stator/rotor cooling oil cooling system, incl. coolant supply system
Hint: for other liquid cooling see *XLF*
Limit: from excl. stator/rotor outlet
to excl. stator/rotor inlet
Task: dissipate heat produced by stator/rotor to coolant
XLV
Lubricant supply system (if separate system for electro-motive units)
XLW
Sealing oil system, incl. supply and treatment
Limit: from excl. branch off sealing oil supply system
to excl. stator inlet and
from excl. stator outlet
to excl. inlet to other system or in closed systems
from excl. stator outlet
to excl. stator inlet
XLX
Fluid supply system for control and protection equipment
XLY
Control and protection equipment
Printout date 14. Mrz. 01
Page XL1 of XL1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : XP
04.04.97
X
Heavy machinery (not main machine sets)
XP
Common installations for heavy machinery
XPA
Foundations
XPB
Sheating
XPG
Frame, support structure
XPR
Forced cooling system
XPS
Drying and layup system
Printout date 14. Mrz. 01
Page XP1 of XP1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : XR
04.04.97
X
Heavy machinery (not main machine sets)
XR
Gas engine plant
XRA
Gas engine plant
XRB
Gas engine plant
XRC
Gas engine plant
XRD
Gas engine plant
XRE
Gas engine plant
XRF
Gas engine plant
XRG
Gas engine plant
XRH
Gas engine plant
XRJ
Gas engine plant
XRK
Gas engine plant
XRL
Gas engine plant
XRM
Gas engine plant
XRN
Gas engine plant
XRP
Gas engine plant
XRQ
Gas engine plant
XRR
Gas engine plant
XRS
Gas engine plant
XRT
Gas engine plant
XRU
Gas engine plant
XRV
Lubricant supply system
XRW
Sealing fluid supply system
XRX
Fluid supply system for control and protection equipment
XRY
Control and protection equipment
Printout date 14. Mrz. 01
Page XR1 of XR1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : XV
04.04.97
X
Heavy machinery (not main machine sets)
XV
Lubricant supply system
XVA
Lubricant supply system
XVB
Lubricant supply system
XVC
Lubricant supply system
XVD
Lubricant supply system
XVE
Lubricant supply system
XVF
Lubricant supply system
XVG
Lubricant supply system
XVH
Lubricant supply system
XVJ
Lubricant supply system
XVK
Lubricant supply system
XVL
Lubricant supply system
XVM
Lubricant supply system
XVN
Lubricant supply system
XVP
Lubricant supply system
XVQ
Lubricant supply system
XVR
Lubricant supply system
XVS
Lubricant supply system
XVT
Lubricant supply system
XVU
Lubricant supply system
Printout date 14. Mrz. 01
Page XV1 of XV1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : XW
04.04.97
X
Heavy machinery (not main machine sets)
XW
Sealing fluid supply system
XWA
Sealing fluid supply system
XWB
Sealing fluid supply system
XWC
Sealing fluid supply system
XWD
Sealing fluid supply system
XWE
Sealing fluid supply system
XWF
Sealing fluid supply system
XWG
Sealing fluid supply system
XWH
Sealing fluid supply system
XWJ
Sealing fluid supply system
XWK
Sealing fluid supply system
XWL
Sealing fluid supply system
XWM
Sealing fluid supply system
XWN
Sealing fluid supply system
XWP
Sealing fluid supply system
XWQ
Sealing fluid supply system
XWR
Sealing fluid supply system
XWS
Sealing fluid supply system
XWT
Sealing fluid supply system
XWU
Sealing fluid supply system
Printout date 14. Mrz. 01
Page XW1 of XW1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : XX
04.04.97
X
Heavy machinery (not main machine sets)
XX
Fluid supply system for control and protection equipment
XXA
Fluid supply system for control and protection equipment
XXB
Fluid supply system for control and protection equipment
XXC
Fluid supply system for control and protection equipment
XXD
Fluid supply system for control and protection equipment
XXE
Fluid supply system for control and protection equipment
XXF
Fluid supply system for control and protection equipment
XXG
Fluid supply system for control and protection equipment
XXH
Fluid supply system for control and protection equipment
XXJ
Fluid supply system for control and protection equipment
XXK
Fluid supply system for control and protection equipment
XXL
Fluid supply system for control and protection equipment
XXM
Fluid supply system for control and protection equipment
XXN
Fluid supply system for control and protection equipment
XXP
Fluid supply system for control and protection equipment
XXQ
Fluid supply system for control and protection equipment
XXR
Fluid supply system for control and protection equipment
XXS
Fluid supply system for control and protection equipment
XXT
Fluid supply system for control and protection equipment
XXU
Fluid supply system for control and protection equipment
Printout date 14. Mrz. 01
Page XX1 of XX1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Function key : XY
04.04.97
X
Heavy machinery (not main machine sets)
XY
Control and protection equipment
XYA
Control and protection equipment
XYB
Control and protection equipment
XYC
Control and protection equipment
XYD
Control and protection equipment
XYE
Control and protection equipment
XYF
Control and protection equipment
XYG
Control and protection equipment
XYH
Control and protection equipment
XYJ
Control and protection equipment
XYK
Control and protection equipment
XYL
Control and protection equipment
XYM
Control and protection equipment
XYN
Control and protection equipment
XYP
Control and protection equipment
XYQ
Control and protection equipment
XYR
Control and protection equipment
XYS
Control and protection equipment
XYT
Control and protection equipment
XYU
Control and protection equipment
Printout date 14. Mrz. 01
Page XY1 of XY1
Siemens
2 nd complete, non-project related edition
Condition-Date:
Z
KKS
Identification System for Power
Plants
Function key : Z
04.04.97
Workshop and office equipment
Printout date 14. Mrz. 01
Page Z1 of Z1
Siemens
2 nd complete, non-project related edition
Identification System for Power
Plants
General view Equipment unit
key
Condition-Date: 04.04.97
A
Mechanical equipment
B
Mechanical equipment
C
Direct measuring circuits
D
Closed loop control circuits
E
Analog and binary signal conditioning
F
Indirect measuring circuits (gated, corrected, suppressed, calculated)
G
Electrical equipment
H
Subassemblies of main and heavy machinery
J
Nuclear assemblies
Printout date: 12. Sep. 01
Page 1 of 1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Equipment unit key
04.04.97
A
Mechanical equipment
AA
Valves, dampers, etc., incl. actuators, also manual, rupture disk equipment
AB
Isolating elements, air locks
AC
Heat exchangers, heat transfer surfaces
AE
Turning, driving, lifting and slewing gear (also manipulators)
AF
Continuous conveyors, feeders (escalators)
AG
Generator units
AH
Heating, cooling and air conditioning units
AJ
Size reduction equipment, only as part of process
AK
Compacting and packaging equipment, only as part of process
AM
Mixers, agitators
AN
Compressor units, fans
AP
Pump units
AS
Adjusting and tensioning equipment for non-electrical variables
AT
Cleaning, drying, filtering and separating equipment, excl. *BT*
AU
Braking, gearbox, coupling equipment, non-electrical converters
AV
Combustion equipment
AW
Stationary tooling, treatment equipment
AX
Test and monitoring equipment for plant maintenance
Printout date 14. Mrz. 01
Page 1 of 9
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Equipment unit key
04.04.97
B
Mechanical equipment
BB
Storage equipment (vessels, tanks)
BE
Shafts (for erection and maintenance only)
BF
Foundations
BN
Jet pumps, ejectors, injectors
BP
Flow restrictors, limiters, orifices (not metering orifices)
BQ
Hangers, supports, racks, piping penetrations
BR
Piping, ductwork, chutes
BS
Silencers
BT
Flue gas catalytic converter modules
BU
Insulation, sheathing
Printout date 14. Mrz. 01
Page 2 of 9
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Equipment unit key
04.04.97
C
Direct measuring circuits
CB
Radiation variables, e. g. thermal radiation, flame monitoring (other than *CR* and
*CQ*)
CD
Density
CE
Electrical variables (e. g. current, voltage, power, electr. frequency)
CF
Flow, rate
CG
Distance, length, position, direction of rotation
CH
Manual input (as manually operated sensor) (e. g. fire detector)
CJ
Power (mechanical, thermal)
CK
Time
CL
Level (also for dividing line)
CM
Moisture, humidity
CP
Pressure
CQ
Quality variables (analysis, material properties other than *CD*, *CM*, *CV*)
CR
Radiation variables
CS
Velocity, speed, frequency (mechanical), acceleration
CT
Temperature
CU
Combined and other variables
CV
Viscosity
CW
Weight, mass
CY
Vibration, expansion
Printout date 14. Mrz. 01
Page 3 of 9
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Equipment unit key
04.04.97
D
Closed loop control circuits
DB
Radiation variables, e. g. thermal radiation, flame monitoring (other than *DR* and
*DQ*)
DD
Density
DE
Electrical variables (e. g. current, voltage, power, electr. frequency)
DF
Flow, rate
DG
Distance, length, position, direction of rotation
DJ
Power (mechanical, thermal)
DK
Time
DL
Level (also for dividing line)
DM
Moisture, humidity
DP
Pressure
DQ
Quality variables (analysis, material properties other than *DD*, *DM*, *DV*)
DR
Radiation variables
DS
Velocity, speed, frequency (mechanical), acceleration
DT
Temperature
DU
Combined and other variables
DV
Viscosity
DW
Weight, mass
DY
Vibration, expansion
Printout date 14. Mrz. 01
Page 4 of 9
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Equipment unit key
04.04.97
E
Analog and binary signal conditioning
EA
Open loop control, unit control
EB
Open loop control, group control
EC
Open loop control, subgroup control
EE
Open loop control, subloop control, equipment unit changeover
EG
Alarm, annunciation, alarm logics
EH
Alarm, annunciation, hard-wired alarm annunciation system
EJ
Alarm, annunciation, visualization of operation and monitoring displays
EK
Alarm, annunciation, alarm logics
EM
Process computer, access control
EN
Process computer, status-display computer, criterion display
EP
Process computer, supervisory computer
EQ
Process computer, internal automation (signal processing)
ES
Process computer, internal automation (signal conditioning)
EU
Combined analog and binary signal conditioning
EV
Signal transmission, bus coupling
EY
Protection, protective logics, priority, non-equipment-unit-related
EZ
Protection, equipment unit protection (superordinate equipment unit protection)
Printout date 14. Mrz. 01
Page 5 of 9
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Equipment unit key
04.04.97
F
Indirect measuring circuits (gated, corrected, suppressed, calculated)
FB
Radiation variables, e. g. thermal radiation, flame monitoring (other than *FR* and
*FQ*)
FD
Density
FE
Electrical variables (e. g. electr. efficiency, power)
FF
Flow, rate
FG
Distance, length, position, direction of rotation
FJ
Power (mechanical, thermal)
FK
Time
FL
Level (also for dividing line)
FM
Moisture, humidity
FP
Pressure
FQ
Quality variables (analysis, material properties other than *FD*, *FM*, *FV*)
FR
Radiation variables
FS
Velocity, speed, frequency (mechanical), acceleration
FT
Temperature
FU
Combined and other variables
FV
Viscosity
FW
Weight, mass
FY
Vibration, expansion
Printout date 14. Mrz. 01
Page 6 of 9
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Equipment unit key
04.04.97
G
Electrical equipment
GA
Junction boxes for analog measured data
GB
Junction boxes for binary signals
GC
Junction boxes for analog safety I&C (SILT) measured data
GD
Junction boxes for power cables > 1 kV
GE
Junction boxes for power cables < 1 kV
GF
Junction boxes for operational I&C (BELT) measured data
GG
Junction boxes for thermocouples
GH
Electrical and instrumentation and control installation units (e. g. cubicles, boxes)
GJ
Processing and storage equipment for process computers and automation
systems (automation equipment and servers, etc.)
GK
Information display and operator control equipment for process computers and
automation systems (keyboards, monitors, printers)
GM
Junction boxes for light-current systems of national telecommunications services
GN
Networking equipment (bus couplers and optic transceivers, etc.)
GP
Subdistribution/junction boxes for lighting
GQ
Subdistribution/junction boxes for power sockets
GR
DC generating equipment, batteries
GS
Switchgear equipment if not identified under process equipment
GT
Transformer equipment
GU
Converter equipment
GV
Structure-related earthing and lightning protection equipment, surge arrestors
GW
Cabinet power supply equipment
GX
Actuating equipment for electrical variables
GY
Junction boxes for light-current systems (not of national telecommunications
services)
GZ
Hangers, supports and racks for electrical and instrumentation and control
equipment
Printout date 14. Mrz. 01
Page 7 of 9
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Equipment unit key
04.04.97
H
Subassemblies of main and heavy machinery
HA
Machine stationary assembly
HB
Machine rotating assembly
HD
Bearing assembly
Printout date 14. Mrz. 01
Page 8 of 9
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Equipment unit key
04.04.97
J
Nuclear assemblies
JA
Absorber assemblies
JB
Fuel assemblies (also includes block-type, cluster-type and spherical fuel
elements)
JC
Breeder assemblies
JD
Flow restrictors (assemblies)
JE
Burnable absorber assemblies
JF
Reflector assemblies
JG
Plenum assemblies
JM
Moderator assemblies
JN
Neutron sources
JS
Shielding equipment
JZ
Special assemblies
Printout date 14. Mrz. 01
Page 9 of 9
Siemens
2 nd complete, non-project related edition
Identification System for Power
Plants
General view Component key
Condition-Date: 04.04.97
-
Electrical components
K
Mechanical components
M
Mechanical components
Q
Instrumentation and control components (non-electrical)
X
Signal origins
Y
Signal applications
Printout date: 12. Sep. 01
Page 1 of 1
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Component key
04.04.97
-
Electrical components
-A
Assemblies and subassemblies
-B
Transducers for non-electrical to electrical variables and vice-versa
-C
Capacitors
-D
Binary elements, delay devices, memory devices
-E
Special components
-F
Protective devices
-G
Generators, power supplies
-H
Signalling devices
-K
Relays, contactors
-L
Inductors
-M
Motors
-N
Amplifiers, controllers
-P
Measuring instruments, testing equipment
-Q
Power switchgear
-R
Resistors
-S
Switches, selectors
-T
Transformers
-U
Modulators, convertors from electrical to other electrical variables
-V
Tubes, semiconductors
-W
Transmission paths, waveguides, aerials
-X
Terminals, plugs, sockets
-Y
Electrical positioners, e. g. solenoids (not motors)
-Z
Terminations, balancing equipment, filters, limiters, cable terminations,
equalizers, hybrid transformers
Printout date 14. Mrz. 01
Page 1 of 6
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Component key
04.04.97
K
Mechanical components
KA
Gate valves, globe valves, dampers, cocks, rupture disks, orifices
KB
Gates, doors, dam boards
KC
Heat exchangers, coolers
KD
Vessels/tanks, pools, surge tanks (fluid systems)
KE
Turning, driving, lifting and slewing gear
KF
Continuous conveyors, feeders
KJ
Size reduction machines
KK
Compacting, packaging machines
KM
Mixers, agitators
KN
Compressors, blowers, fans
KP
Pumps
KT
Cleaning machines, dryers, separators, filters
KV
Burners, grates
KW
Stationary tooling and treatment machines for maintenance
Printout date 14. Mrz. 01
Page 2 of 6
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Component key
04.04.97
M
Mechanical components
MB
Brakes
MF
Foundations
MG
Gearboxes
MK
Clutches, couplings
MM
Engines, not electrical
MR
Piping components, ductwork components
MS
Positioners, not electrical
MT
Turbines
MU
Transmission gear, non electrical, converters and boosters other than couplings
and gearboxes
Printout date 14. Mrz. 01
Page 3 of 6
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Component key
04.04.97
Q
Instrumentation and control components (non-electrical)
QA
Enclosures (for I&C component protection only)
QB
Sensors if not structurally integral with *QP*, metering orifices
QH
Signalling devices
QN
Controllers, flybolt governor
QP
Measuring instruments, testing equipment
QR
Instrument piping
QS
Condensation chambers (datum reservoir) in measuring circuits
QT
Thermowells and pockets for protection of sensors
Printout date 14. Mrz. 01
Page 4 of 6
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Component key
04.04.97
X
Signal origins
XA
Functional group control/subloop control
XB
Control interface
XC
Closed-loop control
XD
Reactor protection, signals in binary signal processing section
XE
Reactor protection, signals in analog and binary sections
XF
Priority control
XG
Binary process signals conditioned by binary signal conditioning modules
XH
Binary limit signals derived from analog process signals
XJ
Signals from non-standard areas (e. g. black box, dedicated I&C)
XK
Equipment unit/component protection
XL
Control room and control stations, signals not assigned to specific control
systems (e. g. control interface tiles)
XM
Alarm signals
XN
Status-display computer/criterion display
XP
Supervisory computer (process computer)
XQ
Analog signals
XR
Priority control and limitation function (controls other than *XC* and *XT*,*YC*
and *YT*)
XS
Functional group control step signals
XT
Turbine generator I&C, binary signals
XU
Non-floating dynamic alarm signals
XW
Hardwired alarm annunciation system
Printout date 14. Mrz. 01
Page 5 of 6
Siemens
2 nd complete, non-project related edition
Condition-Date:
KKS
Identification System for Power
Plants
Component key
04.04.97
Y
Signal applications
YA
Functional group control/subloop control
YB
Control interface
YC
Closed-loop control
YD
Reactor protection, signals in binary signal processing section
YE
Reactor protection, signals in analog and binary sections
YF
Priority control
YJ
Signals from non-standard areas (e. g. black box, dedicated I&C)
YL
Control room and control stations, signals not assigned to specific control
systems (e. g. control interface tiles)
YN
Status-display computer/criterion display
YP
Supervisory computer (process computer)
YQ
Analog signals
YR
Priority control and limitation function (controls other than *XC* and *XT*,*YC*
and *YT*)
YT
Turbine generator I&C, binary signals
YV
Signal gating (protective logic, alarm logic, etc.)
YW
Hardwired alarm annunciation system
Printout date 14. Mrz. 01
Page 6 of 6
Download