RS-100 100W Single Output Switching Power Supply series ■ ‧ ‧ ‧ ‧ ‧ ‧℃ ‧ ‧℃ ‧ ‧ ‧ Bauar t gepruft Sicherheit egel ma ge od o s be wac g www. tuv.com ID 2000000000 SPECIFICATION UL62368-1 MODEL OUTPUT INPUT EN62368-1 IEC62368-1 TPTC004 RS-100-3.3 RS-100-5 RS-100-12 RS-100-15 RS-100-24 RS-100-48 DC VOLTAGE 3.3V 5V 12V 15V 24V 48V RATED CURRENT 20A 16A 8.5A 7A 4.5A 2.3A CURRENT RANGE 0 ~ 20A 0 ~ 16A 0 ~ 8.5A 0 ~ 7A 0 ~ 4.5A 0 ~ 2.3A RATED POWER 66W 80W 102W 105W 108W 110.4W RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 120mVp-p 120mVp-p 120mVp-p 200mVp-p VOLTAGE ADJ. RANGE 4.75 ~ 5.5V ±2.0% 11.4 ~ 13.2V ±1.0% 14.25 ~ 16.5V ±1.0% 22.8 ~ 26.4V ±1.0% 45.6 ~ 52.8V ±1.0% 3.2V ~ 3.5V VOLTAGE TOLERANCE Note.3 ±3.0% LINE REGULATION Note.4 ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% LOAD REGULATION Note.5 ±2.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% 84% 84% 27.6 ~ 32.4V 55.2 ~ 64.8V SETUP, RISE TIME 500ms, 20ms/230VAC HOLD UP TIME (Typ.) 95ms/230VAC VOLTAGE RANGE 88 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 74% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2.5A/115VAC 1.5A/230VAC COLD START 40A/230VAC LEAKAGE CURRENT 1200ms, 30ms/115VAC at full load 17ms/115VAC at full load 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) 77% 81% 82% <2mA / 240VAC 110 ~ 150% rated output power OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 6) EMC EMISSION OTHERS Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70℃ (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85℃, 10 ~ 95% RH ±0.03%/℃ (0 ~ 50℃) 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes UL62368-1, TUV EN62368-1, EAC TP TC 004 approved I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A, EAC TP TC 020 MTBF 260.8Khrs min. MIL-HDBK-217F (25℃) 159*97*38mm (L*W*H) 0.6Kg; 24pcs/15.4Kg/0.7CUFT DIMENSION PACKING NOTE Protection type : Hiccup mode, recovers automatically after fault condition is removed 3.8 ~ 4.45V 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V ℃ For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) ℃℃ ※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:RS-100-SPEC 2020-09-29 RS-100 100W Single Output Switching Power Supply Mechanical Specification Case No. 901C series Unit:mm 3.5 7 152.5 1 3 84.5 8.2 4 5 2-M 6 97 65 9.5 2 3 7 .5 ψ3 4.5 78 24 159 150 Terminal Pin No. Assignment 22 Pin No. 1 2 3 38 M3 3.5 28.5 9 3- 18 3.5 ψ 18.5 9 6.5 Assignment AC/L AC/N FG Pin No. 4,5 6,7 Assignment DC OUTPUT -V DC OUTPUT +V 117 Block Diagram fosc : 60KHz RECTIFIERS & FILTER EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING DETECTION CIRCUIT FG O.L.P. +V -V CONTROL O.V.P. Derating Curve Static Characteristics 100 100 Others 90 80 80 70 3.3V,5V LOAD (%) LOAD (%) 60 40 20 -25 -25 0 0 10 20 30 40 50 AMBIENT TEMPERATURE (℃) 60 70 (HORIZONTAL) 60 50 40 88 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:RS-100-SPEC 2020-09-29