Uploaded by Space Prawns

2100910CYA01 - Road Lighting

advertisement
Senai Road Lighting Simulation
Luminaire: LEDioc/SL-EY686-4-200W-WD
Arrangement: on Median
Pole Distance: 35.000 m & 45.000m
Height: 12.000 m
Overhang (2): 0.000 m
Boom Angle (3): 0.0 °
Boom Length (4): 2.500 m
Lighting Class: ME1
Street Profile
Roadway 2 (Width: 7.000 m, Number of lanes: 2, tarmac: R3, q0: 0.070)
Median 1 (Width: 5.000 m, Height: 0.000 m)
Roadway 1 (Width: 7.000 m, Number of lanes: 2, tarmac: R3, q0: 0.070)
Light loss factor: 0.80
Company: ELM Lighting Sdn. Bhd.
Date: 27.10.2021
Operator:
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Table of contents
Senai Road Lighting Simulation
Project Cover
Table of contents
Luminaire parts list
ELM Lighting Sdn. Bhd. LEDioc/SL-EY686-4-200W-WD
Luminaire Data Sheet
Street 1 (2 roadways, 2 Lanes/roadways )
Planning data
Luminaire parts list
Photometric Results
3D Rendering
False Color Rendering
Valuation Fields
Valuation Field Roadway 1
Results overview
Isolines (E)
Greyscale (E)
Value Chart (E)
Table (E)
Valuation Field Roadway 2
Results overview
Isolines (E)
Greyscale (E)
Value Chart (E)
Table (E)
Street 2 (2 roadways, 2 Lanes/roadways )
Planning data
Luminaire parts list
Photometric Results
3D Rendering
False Color Rendering
Valuation Fields
Valuation Field Roadway 1
Results overview
Isolines (E)
Greyscale (E)
Value Chart (E)
Table (E)
Observer
Observer 1
Isolines (L)
Observer 2
Isolines (L)
Valuation Field Roadway 2
Results overview
Isolines (E)
Greyscale (E)
Value Chart (E)
Table (E)
Observer
Observer 3
Isolines (L)
Observer 4
Isolines (L)
1
2
3
4
5
6
7
9
10
11
12
13
14
15
17
18
19
20
21
23
24
25
27
28
29
30
31
32
33
35
36
37
38
39
40
41
43
44
Page 2
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Senai Road Lighting Simulation / Luminaire parts list
26 Pieces
ELM Lighting Sdn. Bhd. LEDioc/SL-EY686-4200W-WD
Article No.:
Luminous flux (Luminaire): 25681 lm
Luminous flux (Lamps): 25682 lm
Luminaire Wattage: 204.9 W
Luminaire classification according to CIE: 100
CIE flux code: 41 74 96 100 100
Fitting: 1 x User defined (Correction Factor
1.000).
See our luminaire
catalog for an image of
the luminaire.
Page 3
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
ELM Lighting Sdn. Bhd. LEDioc/SL-EY686-4-200W-WD / Luminaire Data Sheet
Luminous emittance 1:
See our luminaire catalog for an image of the
luminaire.
Luminaire classification according to CIE: 100
CIE flux code: 41 74 96 100 100
Due to missing symmetry properties, no UGR table
can be displayed for this luminaire.
Page 4
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 1 (2 roadways, 2 Lanes/roadways ) / Planning data
Street Profile
Roadway 2
Median 1
Roadway 1
(Width: 7.000 m, Number of lanes: 2, tarmac: R3, q0: 0.070)
(Width: 5.000 m, Height: 0.000 m)
(Width: 7.000 m, Number of lanes: 2, tarmac: R3, q0: 0.070)
Light loss factor: 0.80
Luminaire Arrangements
Luminaire:
Luminous flux (Luminaire):
Luminous flux (Lamps):
Luminaire Wattage:
Arrangement:
Pole Distance:
Mounting Height (1):
Height:
Overhang (2):
Boom Angle (3):
Boom Length (4):
ELM Lighting Sdn. Bhd. LEDioc/SL-EY686-4-200W-WD
25681 lm
Maximum luminous intensities
25682 lm
489 cd/klm
at 70°:
204.9 W
at 80°:
190 cd/klm
on Median
at 90°:
0.37 cd/klm
Any direction forming the specified angle from the downward vertical, with the luminaire
35.000 m
installed for use.
12.100 m
12.000 m
Arrangement complies with luminous intensity class G1.
0.000 m
Arrangement complies with glare index class D.3.
0.0 °
2.500 m
Page 5
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 1 (2 roadways, 2 Lanes/roadways ) / Luminaire parts list
ELM Lighting Sdn. Bhd. LEDioc/SL-EY686-4200W-WD
Article No.:
Luminous flux (Luminaire): 25681 lm
Luminous flux (Lamps): 25682 lm
Luminaire Wattage: 204.9 W
Luminaire classification according to CIE: 100
CIE flux code: 41 74 96 100 100
Fitting: 1 x User defined (Correction Factor
1.000).
See our luminaire
catalog for an image of
the luminaire.
Page 6
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 1 (2 roadways, 2 Lanes/roadways ) / Photometric Results
Light loss factor: 0.80
Scale 1:294
Calculation Field List
1
Valuation Field Roadway 1
Length: 35.000 m, Width: 7.000 m
Grid: 12 x 6 Points
Accompanying Street Elements: Roadway 1.
tarmac: R3, q0: 0.070
(All lighting performance requirements are met.)
Selected Lighting Class: ME1
Calculated values:
Required values according to class:
Fulfilled/Not fulfilled:
Lav [cd/m²]
2.90
≥ 2.00
U0
0.58
≥ 0.40
Ul
0.90
≥ 0.70
TI [%]
10
≤ 10
SR
0.86
≥ 0.50
Page 7
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 1 (2 roadways, 2 Lanes/roadways ) / Photometric Results
Calculation Field List
2
Valuation Field Roadway 2
Length: 35.000 m, Width: 7.000 m
Grid: 12 x 6 Points
Accompanying Street Elements: Roadway 2.
tarmac: R3, q0: 0.070
(All lighting performance requirements are met.)
Selected Lighting Class: ME1
Calculated values:
Required values according to class:
Fulfilled/Not fulfilled:
Lav [cd/m²]
2.90
≥ 2.00
U0
0.58
≥ 0.40
Ul
0.90
≥ 0.70
TI [%]
10
≤ 10
SR
0.86
≥ 0.50
Page 8
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 1 (2 roadways, 2 Lanes/roadways ) / 3D Rendering
Page 9
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 1 (2 roadways, 2 Lanes/roadways ) / False Color Rendering
Page 10
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 1 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Results
overview
Light loss factor: 0.80
Scale 1:294
Grid: 12 x 6 Points
Accompanying Street Elements: Roadway 1.
tarmac: R3, q0: 0.070
(All lighting performance requirements are met.)
Selected Lighting Class: ME1
Calculated values:
Required values according to class:
Fulfilled/Not fulfilled:
Lav [cd/m²]
2.90
≥ 2.00
U0
0.58
≥ 0.40
Ul
0.90
≥ 0.70
TI [%]
10
≤ 10
SR
0.86
≥ 0.50
Assigned observer (2 Pieces):
No.
1
2
Observer
Position [m]
Observer 1
Observer 2
(-60.000, 1.750, 1.500)
(-60.000, 5.250, 1.500)
Lav [cd/m²]
U0
Ul
TI [%]
3.22
2.90
0.58
0.59
0.92
0.90
7
10
Page 11
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 1 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Isolines (E)
Values in Lux, Scale 1 : 294
Grid: 12 x 6 Points
Eav [lx]
42
Emin [lx]
27
Emax [lx]
58
u0
0.644
Emin / Emax
0.467
Page 12
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 1 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Greyscale (E)
Scale 1 : 294
Grid: 12 x 6 Points
Eav [lx]
42
Emin [lx]
27
Emax [lx]
58
u0
0.644
Emin / Emax
0.467
Page 13
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 1 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Value Chart
(E)
Values in Lux, Scale 1 : 294
Not all calculated values could be displayed.
Grid: 12 x 6 Points
Eav [lx]
42
Emin [lx]
27
Emax [lx]
58
u0
0.644
Emin / Emax
0.467
Page 14
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 1 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Table (E)
6.417
57
53
49
42
36
34
34
36
42
49
5.250
58
54
48
41
35
32
32
35
41
48
4.083
57
54
47
41
34
32
32
34
41
47
2.917
54
51
46
39
33
30
30
33
39
46
1.750
50
47
43
37
32
29
29
32
37
43
0.583
43
41
38
34
30
27
27
30
34
38
m
1.458
4.375
7.292
10.208
13.125
16.042
18.958
21.875
24.792
27.708
Attention: The coordinates refer to the image above. Values in Lux.
Grid: 12 x 6 Points
Eav [lx]
42
Emin [lx]
27
Emax [lx]
58
u0
0.644
Emin / Emax
0.467
Page 15
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 1 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Table (E)
6.417
53
57
5.250
54
58
4.083
54
57
2.917
51
54
1.750
47
50
0.583
41
43
m
30.625
33.542
Attention: The coordinates refer to the image above. Values in Lux.
Grid: 12 x 6 Points
Eav [lx]
42
Emin [lx]
27
Emax [lx]
58
u0
0.644
Emin / Emax
0.467
Page 16
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 1 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Results
overview
Light loss factor: 0.80
Scale 1:294
Grid: 12 x 6 Points
Accompanying Street Elements: Roadway 2.
tarmac: R3, q0: 0.070
(All lighting performance requirements are met.)
Selected Lighting Class: ME1
Calculated values:
Required values according to class:
Fulfilled/Not fulfilled:
Lav [cd/m²]
2.90
≥ 2.00
U0
0.58
≥ 0.40
Ul
0.90
≥ 0.70
TI [%]
10
≤ 10
SR
0.86
≥ 0.50
Assigned observer (2 Pieces):
No.
1
2
Observer
Position [m]
Observer 3
Observer 4
(-60.000, 13.750, 1.500)
(-60.000, 17.250, 1.500)
Lav [cd/m²]
U0
Ul
TI [%]
2.90
3.22
0.59
0.58
0.90
0.92
10
7
Page 17
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 1 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Isolines (E)
Values in Lux, Scale 1 : 294
Grid: 12 x 6 Points
Eav [lx]
42
Emin [lx]
27
Emax [lx]
58
u0
0.644
Emin / Emax
0.467
Page 18
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 1 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Greyscale (E)
Scale 1 : 294
Grid: 12 x 6 Points
Eav [lx]
42
Emin [lx]
27
Emax [lx]
58
u0
0.644
Emin / Emax
0.467
Page 19
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 1 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Value Chart
(E)
Values in Lux, Scale 1 : 294
Not all calculated values could be displayed.
Grid: 12 x 6 Points
Eav [lx]
42
Emin [lx]
27
Emax [lx]
58
u0
0.644
Emin / Emax
0.467
Page 20
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 1 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Table (E)
6.417
43
41
38
34
30
27
27
30
34
38
5.250
50
47
43
37
32
29
29
32
37
43
4.083
54
51
46
39
33
30
30
33
39
46
2.917
57
54
47
41
34
32
32
34
41
47
1.750
58
54
48
41
35
32
32
35
41
48
0.583
57
53
49
42
36
34
34
36
42
49
m
1.458
4.375
7.292
10.208
13.125
16.042
18.958
21.875
24.792
27.708
Attention: The coordinates refer to the image above. Values in Lux.
Grid: 12 x 6 Points
Eav [lx]
42
Emin [lx]
27
Emax [lx]
58
u0
0.644
Emin / Emax
0.467
Page 21
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 1 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Table (E)
6.417
41
43
5.250
47
50
4.083
51
54
2.917
54
57
1.750
54
58
0.583
53
57
m
30.625
33.542
Attention: The coordinates refer to the image above. Values in Lux.
Grid: 12 x 6 Points
Eav [lx]
42
Emin [lx]
27
Emax [lx]
58
u0
0.644
Emin / Emax
0.467
Page 22
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 2 (2 roadways, 2 Lanes/roadways ) / Planning data
Street Profile
Roadway 2
Median 1
Roadway 1
(Width: 7.000 m, Number of lanes: 2, tarmac: R3, q0: 0.070)
(Width: 5.000 m, Height: 0.000 m)
(Width: 7.000 m, Number of lanes: 2, tarmac: R3, q0: 0.070)
Light loss factor: 0.80
Luminaire Arrangements
Luminaire:
Luminous flux (Luminaire):
Luminous flux (Lamps):
Luminaire Wattage:
Arrangement:
Pole Distance:
Mounting Height (1):
Height:
Overhang (2):
Boom Angle (3):
Boom Length (4):
ELM Lighting Sdn. Bhd. LEDioc/SL-EY686-4-200W-WD
25681 lm
Maximum luminous intensities
25682 lm
499 cd/klm
at 70°:
204.9 W
at 80°:
241 cd/klm
on Median
at 90°:
3.06 cd/klm
Any direction forming the specified angle from the downward vertical, with the luminaire
45.000 m
installed for use.
12.100 m
12.000 m
Arrangement complies with glare index class D.0.
0.000 m
5.0 °
2.491 m
Page 23
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 2 (2 roadways, 2 Lanes/roadways ) / Luminaire parts list
ELM Lighting Sdn. Bhd. LEDioc/SL-EY686-4200W-WD
Article No.:
Luminous flux (Luminaire): 25681 lm
Luminous flux (Lamps): 25682 lm
Luminaire Wattage: 204.9 W
Luminaire classification according to CIE: 100
CIE flux code: 41 74 96 100 100
Fitting: 1 x User defined (Correction Factor
1.000).
See our luminaire
catalog for an image of
the luminaire.
Page 24
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 2 (2 roadways, 2 Lanes/roadways ) / Photometric Results
Light loss factor: 0.80
Scale 1:365
Calculation Field List
1
Valuation Field Roadway 1
Length: 45.000 m, Width: 7.000 m
Grid: 15 x 6 Points
Accompanying Street Elements: Roadway 1.
tarmac: R3, q0: 0.070
(All lighting performance requirements are met.)
Selected Lighting Class: ME1
Calculated values:
Required values according to class:
Fulfilled/Not fulfilled:
Lav [cd/m²]
2.14
≥ 2.00
U0
0.57
≥ 0.40
Ul
0.79
≥ 0.70
TI [%]
10
≤ 10
SR
0.84
≥ 0.50
Page 25
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 2 (2 roadways, 2 Lanes/roadways ) / Photometric Results
Calculation Field List
2
Valuation Field Roadway 2
Length: 45.000 m, Width: 7.000 m
Grid: 15 x 6 Points
Accompanying Street Elements: Roadway 2.
tarmac: R3, q0: 0.070
(All lighting performance requirements are met.)
Selected Lighting Class: ME1
Calculated values:
Required values according to class:
Fulfilled/Not fulfilled:
Lav [cd/m²]
2.14
≥ 2.00
U0
0.57
≥ 0.40
Ul
0.79
≥ 0.70
TI [%]
10
≤ 10
SR
0.84
≥ 0.50
Page 26
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 2 (2 roadways, 2 Lanes/roadways ) / 3D Rendering
Page 27
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 2 (2 roadways, 2 Lanes/roadways ) / False Color Rendering
Page 28
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Results
overview
Light loss factor: 0.80
Scale 1:365
Grid: 15 x 6 Points
Accompanying Street Elements: Roadway 1.
tarmac: R3, q0: 0.070
(All lighting performance requirements are met.)
Selected Lighting Class: ME1
Calculated values:
Required values according to class:
Fulfilled/Not fulfilled:
Lav [cd/m²]
2.14
≥ 2.00
U0
0.57
≥ 0.40
Ul
0.79
≥ 0.70
TI [%]
10
≤ 10
SR
0.84
≥ 0.50
Assigned observer (2 Pieces):
No.
1
2
Observer
Position [m]
Observer 1
Observer 2
(-60.000, 1.750, 1.500)
(-60.000, 5.250, 1.500)
Lav [cd/m²]
U0
Ul
TI [%]
2.35
2.14
0.58
0.57
0.79
0.86
8
10
Page 29
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Isolines (E)
Values in Lux, Scale 1 : 365
Grid: 15 x 6 Points
Eav [lx]
31
Emin [lx]
16
Emax [lx]
50
u0
0.515
Emin / Emax
0.313
Page 30
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Greyscale (E)
Scale 1 : 365
Grid: 15 x 6 Points
Eav [lx]
31
Emin [lx]
16
Emax [lx]
50
u0
0.515
Emin / Emax
0.313
Page 31
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Value Chart
(E)
Values in Lux, Scale 1 : 365
Not all calculated values could be displayed.
Grid: 15 x 6 Points
Eav [lx]
31
Emin [lx]
16
Emax [lx]
50
u0
0.515
Emin / Emax
0.313
Page 32
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Table (E)
6.417
47
44
38
31
25
21
18
18
18
21
5.250
50
46
39
31
24
20
18
17
18
20
4.083
50
47
40
32
25
20
18
17
18
20
2.917
49
45
39
32
24
20
17
17
17
20
1.750
46
43
37
31
24
20
17
16
17
20
0.583
41
39
34
29
23
19
17
16
17
19
m
1.500
4.500
7.500
10.500
13.500
16.500
19.500
22.500
25.500
28.500
Attention: The coordinates refer to the image above. Values in Lux.
Grid: 15 x 6 Points
Eav [lx]
31
Emin [lx]
16
Emax [lx]
50
u0
0.515
Emin / Emax
0.313
Page 33
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Table (E)
6.417
25
31
38
44
47
5.250
24
31
39
46
50
4.083
25
32
40
47
50
2.917
24
32
39
45
49
1.750
24
31
37
43
46
0.583
23
29
34
39
41
m
31.500
34.500
37.500
40.500
43.500
Attention: The coordinates refer to the image above. Values in Lux.
Grid: 15 x 6 Points
Eav [lx]
31
Emin [lx]
16
Emax [lx]
50
u0
0.515
Emin / Emax
0.313
Page 34
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Observer 1 /
Isolines (L)
Values in Candela/m², Scale 1 : 365
Grid: 15 x 6 Points
Observer Position: (-60.000 m, 1.750 m, 1.500 m)
tarmac: R3, q0: 0.070
Calculated values:
Required values according to class ME1:
Lav [cd/m²]
2.35
U0
0.58
Ul
0.79
TI [%]
8
≥ 2.00
≥ 0.40
≥ 0.70
≤ 10
Fulfilled/Not fulfilled:
Page 35
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Observer 2 /
Isolines (L)
Values in Candela/m², Scale 1 : 365
Grid: 15 x 6 Points
Observer Position: (-60.000 m, 5.250 m, 1.500 m)
tarmac: R3, q0: 0.070
Calculated values:
Required values according to class ME1:
Lav [cd/m²]
2.14
U0
0.57
Ul
0.86
TI [%]
10
≥ 2.00
≥ 0.40
≥ 0.70
≤ 10
Fulfilled/Not fulfilled:
Page 36
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Results
overview
Light loss factor: 0.80
Scale 1:365
Grid: 15 x 6 Points
Accompanying Street Elements: Roadway 2.
tarmac: R3, q0: 0.070
(All lighting performance requirements are met.)
Selected Lighting Class: ME1
Calculated values:
Required values according to class:
Fulfilled/Not fulfilled:
Lav [cd/m²]
2.14
≥ 2.00
U0
0.57
≥ 0.40
Ul
0.79
≥ 0.70
TI [%]
10
≤ 10
SR
0.84
≥ 0.50
Assigned observer (2 Pieces):
No.
1
2
Observer
Position [m]
Observer 3
Observer 4
(-60.000, 13.750, 1.500)
(-60.000, 17.250, 1.500)
Lav [cd/m²]
U0
Ul
TI [%]
2.14
2.35
0.57
0.58
0.86
0.79
10
8
Page 37
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Isolines (E)
Values in Lux, Scale 1 : 365
Grid: 15 x 6 Points
Eav [lx]
31
Emin [lx]
16
Emax [lx]
50
u0
0.515
Emin / Emax
0.313
Page 38
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Greyscale (E)
Scale 1 : 365
Grid: 15 x 6 Points
Eav [lx]
31
Emin [lx]
16
Emax [lx]
50
u0
0.515
Emin / Emax
0.313
Page 39
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Value Chart
(E)
Values in Lux, Scale 1 : 365
Not all calculated values could be displayed.
Grid: 15 x 6 Points
Eav [lx]
31
Emin [lx]
16
Emax [lx]
50
u0
0.515
Emin / Emax
0.313
Page 40
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Table (E)
6.417
41
39
34
29
23
19
17
16
17
19
5.250
46
43
37
31
24
20
17
16
17
20
4.083
49
45
39
32
24
20
17
17
17
20
2.917
50
47
40
32
25
20
18
17
18
20
1.750
50
46
39
31
24
20
18
17
18
20
0.583
47
44
38
31
25
21
18
18
18
21
m
1.500
4.500
7.500
10.500
13.500
16.500
19.500
22.500
25.500
28.500
Attention: The coordinates refer to the image above. Values in Lux.
Grid: 15 x 6 Points
Eav [lx]
31
Emin [lx]
16
Emax [lx]
50
u0
0.515
Emin / Emax
0.313
Page 41
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Table (E)
6.417
23
29
34
39
41
5.250
24
31
37
43
46
4.083
24
32
39
45
49
2.917
25
32
40
47
50
1.750
24
31
39
46
50
0.583
25
31
38
44
47
m
31.500
34.500
37.500
40.500
43.500
Attention: The coordinates refer to the image above. Values in Lux.
Grid: 15 x 6 Points
Eav [lx]
31
Emin [lx]
16
Emax [lx]
50
u0
0.515
Emin / Emax
0.313
Page 42
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Observer 3 /
Isolines (L)
Values in Candela/m², Scale 1 : 365
Grid: 15 x 6 Points
Observer Position: (-60.000 m, 13.750 m, 1.500 m)
tarmac: R3, q0: 0.070
Calculated values:
Required values according to class ME1:
Lav [cd/m²]
2.14
U0
0.57
Ul
0.86
TI [%]
10
≥ 2.00
≥ 0.40
≥ 0.70
≤ 10
Fulfilled/Not fulfilled:
Page 43
Senai Road Lighting Simulation
27.10.2021
Operator
Telephone
Fax
e-Mail
Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Observer 4 /
Isolines (L)
Values in Candela/m², Scale 1 : 365
Grid: 15 x 6 Points
Observer Position: (-60.000 m, 17.250 m, 1.500 m)
tarmac: R3, q0: 0.070
Calculated values:
Required values according to class ME1:
Lav [cd/m²]
2.35
U0
0.58
Ul
0.79
TI [%]
8
≥ 2.00
≥ 0.40
≥ 0.70
≤ 10
Fulfilled/Not fulfilled:
Page 44
Download