Senai Road Lighting Simulation Luminaire: LEDioc/SL-EY686-4-200W-WD Arrangement: on Median Pole Distance: 35.000 m & 45.000m Height: 12.000 m Overhang (2): 0.000 m Boom Angle (3): 0.0 ° Boom Length (4): 2.500 m Lighting Class: ME1 Street Profile Roadway 2 (Width: 7.000 m, Number of lanes: 2, tarmac: R3, q0: 0.070) Median 1 (Width: 5.000 m, Height: 0.000 m) Roadway 1 (Width: 7.000 m, Number of lanes: 2, tarmac: R3, q0: 0.070) Light loss factor: 0.80 Company: ELM Lighting Sdn. Bhd. Date: 27.10.2021 Operator: Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Table of contents Senai Road Lighting Simulation Project Cover Table of contents Luminaire parts list ELM Lighting Sdn. Bhd. LEDioc/SL-EY686-4-200W-WD Luminaire Data Sheet Street 1 (2 roadways, 2 Lanes/roadways ) Planning data Luminaire parts list Photometric Results 3D Rendering False Color Rendering Valuation Fields Valuation Field Roadway 1 Results overview Isolines (E) Greyscale (E) Value Chart (E) Table (E) Valuation Field Roadway 2 Results overview Isolines (E) Greyscale (E) Value Chart (E) Table (E) Street 2 (2 roadways, 2 Lanes/roadways ) Planning data Luminaire parts list Photometric Results 3D Rendering False Color Rendering Valuation Fields Valuation Field Roadway 1 Results overview Isolines (E) Greyscale (E) Value Chart (E) Table (E) Observer Observer 1 Isolines (L) Observer 2 Isolines (L) Valuation Field Roadway 2 Results overview Isolines (E) Greyscale (E) Value Chart (E) Table (E) Observer Observer 3 Isolines (L) Observer 4 Isolines (L) 1 2 3 4 5 6 7 9 10 11 12 13 14 15 17 18 19 20 21 23 24 25 27 28 29 30 31 32 33 35 36 37 38 39 40 41 43 44 Page 2 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Senai Road Lighting Simulation / Luminaire parts list 26 Pieces ELM Lighting Sdn. Bhd. LEDioc/SL-EY686-4200W-WD Article No.: Luminous flux (Luminaire): 25681 lm Luminous flux (Lamps): 25682 lm Luminaire Wattage: 204.9 W Luminaire classification according to CIE: 100 CIE flux code: 41 74 96 100 100 Fitting: 1 x User defined (Correction Factor 1.000). See our luminaire catalog for an image of the luminaire. Page 3 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail ELM Lighting Sdn. Bhd. LEDioc/SL-EY686-4-200W-WD / Luminaire Data Sheet Luminous emittance 1: See our luminaire catalog for an image of the luminaire. Luminaire classification according to CIE: 100 CIE flux code: 41 74 96 100 100 Due to missing symmetry properties, no UGR table can be displayed for this luminaire. Page 4 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 1 (2 roadways, 2 Lanes/roadways ) / Planning data Street Profile Roadway 2 Median 1 Roadway 1 (Width: 7.000 m, Number of lanes: 2, tarmac: R3, q0: 0.070) (Width: 5.000 m, Height: 0.000 m) (Width: 7.000 m, Number of lanes: 2, tarmac: R3, q0: 0.070) Light loss factor: 0.80 Luminaire Arrangements Luminaire: Luminous flux (Luminaire): Luminous flux (Lamps): Luminaire Wattage: Arrangement: Pole Distance: Mounting Height (1): Height: Overhang (2): Boom Angle (3): Boom Length (4): ELM Lighting Sdn. Bhd. LEDioc/SL-EY686-4-200W-WD 25681 lm Maximum luminous intensities 25682 lm 489 cd/klm at 70°: 204.9 W at 80°: 190 cd/klm on Median at 90°: 0.37 cd/klm Any direction forming the specified angle from the downward vertical, with the luminaire 35.000 m installed for use. 12.100 m 12.000 m Arrangement complies with luminous intensity class G1. 0.000 m Arrangement complies with glare index class D.3. 0.0 ° 2.500 m Page 5 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 1 (2 roadways, 2 Lanes/roadways ) / Luminaire parts list ELM Lighting Sdn. Bhd. LEDioc/SL-EY686-4200W-WD Article No.: Luminous flux (Luminaire): 25681 lm Luminous flux (Lamps): 25682 lm Luminaire Wattage: 204.9 W Luminaire classification according to CIE: 100 CIE flux code: 41 74 96 100 100 Fitting: 1 x User defined (Correction Factor 1.000). See our luminaire catalog for an image of the luminaire. Page 6 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 1 (2 roadways, 2 Lanes/roadways ) / Photometric Results Light loss factor: 0.80 Scale 1:294 Calculation Field List 1 Valuation Field Roadway 1 Length: 35.000 m, Width: 7.000 m Grid: 12 x 6 Points Accompanying Street Elements: Roadway 1. tarmac: R3, q0: 0.070 (All lighting performance requirements are met.) Selected Lighting Class: ME1 Calculated values: Required values according to class: Fulfilled/Not fulfilled: Lav [cd/m²] 2.90 ≥ 2.00 U0 0.58 ≥ 0.40 Ul 0.90 ≥ 0.70 TI [%] 10 ≤ 10 SR 0.86 ≥ 0.50 Page 7 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 1 (2 roadways, 2 Lanes/roadways ) / Photometric Results Calculation Field List 2 Valuation Field Roadway 2 Length: 35.000 m, Width: 7.000 m Grid: 12 x 6 Points Accompanying Street Elements: Roadway 2. tarmac: R3, q0: 0.070 (All lighting performance requirements are met.) Selected Lighting Class: ME1 Calculated values: Required values according to class: Fulfilled/Not fulfilled: Lav [cd/m²] 2.90 ≥ 2.00 U0 0.58 ≥ 0.40 Ul 0.90 ≥ 0.70 TI [%] 10 ≤ 10 SR 0.86 ≥ 0.50 Page 8 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 1 (2 roadways, 2 Lanes/roadways ) / 3D Rendering Page 9 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 1 (2 roadways, 2 Lanes/roadways ) / False Color Rendering Page 10 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 1 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Results overview Light loss factor: 0.80 Scale 1:294 Grid: 12 x 6 Points Accompanying Street Elements: Roadway 1. tarmac: R3, q0: 0.070 (All lighting performance requirements are met.) Selected Lighting Class: ME1 Calculated values: Required values according to class: Fulfilled/Not fulfilled: Lav [cd/m²] 2.90 ≥ 2.00 U0 0.58 ≥ 0.40 Ul 0.90 ≥ 0.70 TI [%] 10 ≤ 10 SR 0.86 ≥ 0.50 Assigned observer (2 Pieces): No. 1 2 Observer Position [m] Observer 1 Observer 2 (-60.000, 1.750, 1.500) (-60.000, 5.250, 1.500) Lav [cd/m²] U0 Ul TI [%] 3.22 2.90 0.58 0.59 0.92 0.90 7 10 Page 11 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 1 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Isolines (E) Values in Lux, Scale 1 : 294 Grid: 12 x 6 Points Eav [lx] 42 Emin [lx] 27 Emax [lx] 58 u0 0.644 Emin / Emax 0.467 Page 12 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 1 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Greyscale (E) Scale 1 : 294 Grid: 12 x 6 Points Eav [lx] 42 Emin [lx] 27 Emax [lx] 58 u0 0.644 Emin / Emax 0.467 Page 13 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 1 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Value Chart (E) Values in Lux, Scale 1 : 294 Not all calculated values could be displayed. Grid: 12 x 6 Points Eav [lx] 42 Emin [lx] 27 Emax [lx] 58 u0 0.644 Emin / Emax 0.467 Page 14 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 1 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Table (E) 6.417 57 53 49 42 36 34 34 36 42 49 5.250 58 54 48 41 35 32 32 35 41 48 4.083 57 54 47 41 34 32 32 34 41 47 2.917 54 51 46 39 33 30 30 33 39 46 1.750 50 47 43 37 32 29 29 32 37 43 0.583 43 41 38 34 30 27 27 30 34 38 m 1.458 4.375 7.292 10.208 13.125 16.042 18.958 21.875 24.792 27.708 Attention: The coordinates refer to the image above. Values in Lux. Grid: 12 x 6 Points Eav [lx] 42 Emin [lx] 27 Emax [lx] 58 u0 0.644 Emin / Emax 0.467 Page 15 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 1 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Table (E) 6.417 53 57 5.250 54 58 4.083 54 57 2.917 51 54 1.750 47 50 0.583 41 43 m 30.625 33.542 Attention: The coordinates refer to the image above. Values in Lux. Grid: 12 x 6 Points Eav [lx] 42 Emin [lx] 27 Emax [lx] 58 u0 0.644 Emin / Emax 0.467 Page 16 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 1 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Results overview Light loss factor: 0.80 Scale 1:294 Grid: 12 x 6 Points Accompanying Street Elements: Roadway 2. tarmac: R3, q0: 0.070 (All lighting performance requirements are met.) Selected Lighting Class: ME1 Calculated values: Required values according to class: Fulfilled/Not fulfilled: Lav [cd/m²] 2.90 ≥ 2.00 U0 0.58 ≥ 0.40 Ul 0.90 ≥ 0.70 TI [%] 10 ≤ 10 SR 0.86 ≥ 0.50 Assigned observer (2 Pieces): No. 1 2 Observer Position [m] Observer 3 Observer 4 (-60.000, 13.750, 1.500) (-60.000, 17.250, 1.500) Lav [cd/m²] U0 Ul TI [%] 2.90 3.22 0.59 0.58 0.90 0.92 10 7 Page 17 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 1 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Isolines (E) Values in Lux, Scale 1 : 294 Grid: 12 x 6 Points Eav [lx] 42 Emin [lx] 27 Emax [lx] 58 u0 0.644 Emin / Emax 0.467 Page 18 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 1 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Greyscale (E) Scale 1 : 294 Grid: 12 x 6 Points Eav [lx] 42 Emin [lx] 27 Emax [lx] 58 u0 0.644 Emin / Emax 0.467 Page 19 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 1 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Value Chart (E) Values in Lux, Scale 1 : 294 Not all calculated values could be displayed. Grid: 12 x 6 Points Eav [lx] 42 Emin [lx] 27 Emax [lx] 58 u0 0.644 Emin / Emax 0.467 Page 20 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 1 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Table (E) 6.417 43 41 38 34 30 27 27 30 34 38 5.250 50 47 43 37 32 29 29 32 37 43 4.083 54 51 46 39 33 30 30 33 39 46 2.917 57 54 47 41 34 32 32 34 41 47 1.750 58 54 48 41 35 32 32 35 41 48 0.583 57 53 49 42 36 34 34 36 42 49 m 1.458 4.375 7.292 10.208 13.125 16.042 18.958 21.875 24.792 27.708 Attention: The coordinates refer to the image above. Values in Lux. Grid: 12 x 6 Points Eav [lx] 42 Emin [lx] 27 Emax [lx] 58 u0 0.644 Emin / Emax 0.467 Page 21 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 1 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Table (E) 6.417 41 43 5.250 47 50 4.083 51 54 2.917 54 57 1.750 54 58 0.583 53 57 m 30.625 33.542 Attention: The coordinates refer to the image above. Values in Lux. Grid: 12 x 6 Points Eav [lx] 42 Emin [lx] 27 Emax [lx] 58 u0 0.644 Emin / Emax 0.467 Page 22 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 2 (2 roadways, 2 Lanes/roadways ) / Planning data Street Profile Roadway 2 Median 1 Roadway 1 (Width: 7.000 m, Number of lanes: 2, tarmac: R3, q0: 0.070) (Width: 5.000 m, Height: 0.000 m) (Width: 7.000 m, Number of lanes: 2, tarmac: R3, q0: 0.070) Light loss factor: 0.80 Luminaire Arrangements Luminaire: Luminous flux (Luminaire): Luminous flux (Lamps): Luminaire Wattage: Arrangement: Pole Distance: Mounting Height (1): Height: Overhang (2): Boom Angle (3): Boom Length (4): ELM Lighting Sdn. Bhd. LEDioc/SL-EY686-4-200W-WD 25681 lm Maximum luminous intensities 25682 lm 499 cd/klm at 70°: 204.9 W at 80°: 241 cd/klm on Median at 90°: 3.06 cd/klm Any direction forming the specified angle from the downward vertical, with the luminaire 45.000 m installed for use. 12.100 m 12.000 m Arrangement complies with glare index class D.0. 0.000 m 5.0 ° 2.491 m Page 23 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 2 (2 roadways, 2 Lanes/roadways ) / Luminaire parts list ELM Lighting Sdn. Bhd. LEDioc/SL-EY686-4200W-WD Article No.: Luminous flux (Luminaire): 25681 lm Luminous flux (Lamps): 25682 lm Luminaire Wattage: 204.9 W Luminaire classification according to CIE: 100 CIE flux code: 41 74 96 100 100 Fitting: 1 x User defined (Correction Factor 1.000). See our luminaire catalog for an image of the luminaire. Page 24 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 2 (2 roadways, 2 Lanes/roadways ) / Photometric Results Light loss factor: 0.80 Scale 1:365 Calculation Field List 1 Valuation Field Roadway 1 Length: 45.000 m, Width: 7.000 m Grid: 15 x 6 Points Accompanying Street Elements: Roadway 1. tarmac: R3, q0: 0.070 (All lighting performance requirements are met.) Selected Lighting Class: ME1 Calculated values: Required values according to class: Fulfilled/Not fulfilled: Lav [cd/m²] 2.14 ≥ 2.00 U0 0.57 ≥ 0.40 Ul 0.79 ≥ 0.70 TI [%] 10 ≤ 10 SR 0.84 ≥ 0.50 Page 25 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 2 (2 roadways, 2 Lanes/roadways ) / Photometric Results Calculation Field List 2 Valuation Field Roadway 2 Length: 45.000 m, Width: 7.000 m Grid: 15 x 6 Points Accompanying Street Elements: Roadway 2. tarmac: R3, q0: 0.070 (All lighting performance requirements are met.) Selected Lighting Class: ME1 Calculated values: Required values according to class: Fulfilled/Not fulfilled: Lav [cd/m²] 2.14 ≥ 2.00 U0 0.57 ≥ 0.40 Ul 0.79 ≥ 0.70 TI [%] 10 ≤ 10 SR 0.84 ≥ 0.50 Page 26 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 2 (2 roadways, 2 Lanes/roadways ) / 3D Rendering Page 27 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 2 (2 roadways, 2 Lanes/roadways ) / False Color Rendering Page 28 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Results overview Light loss factor: 0.80 Scale 1:365 Grid: 15 x 6 Points Accompanying Street Elements: Roadway 1. tarmac: R3, q0: 0.070 (All lighting performance requirements are met.) Selected Lighting Class: ME1 Calculated values: Required values according to class: Fulfilled/Not fulfilled: Lav [cd/m²] 2.14 ≥ 2.00 U0 0.57 ≥ 0.40 Ul 0.79 ≥ 0.70 TI [%] 10 ≤ 10 SR 0.84 ≥ 0.50 Assigned observer (2 Pieces): No. 1 2 Observer Position [m] Observer 1 Observer 2 (-60.000, 1.750, 1.500) (-60.000, 5.250, 1.500) Lav [cd/m²] U0 Ul TI [%] 2.35 2.14 0.58 0.57 0.79 0.86 8 10 Page 29 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Isolines (E) Values in Lux, Scale 1 : 365 Grid: 15 x 6 Points Eav [lx] 31 Emin [lx] 16 Emax [lx] 50 u0 0.515 Emin / Emax 0.313 Page 30 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Greyscale (E) Scale 1 : 365 Grid: 15 x 6 Points Eav [lx] 31 Emin [lx] 16 Emax [lx] 50 u0 0.515 Emin / Emax 0.313 Page 31 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Value Chart (E) Values in Lux, Scale 1 : 365 Not all calculated values could be displayed. Grid: 15 x 6 Points Eav [lx] 31 Emin [lx] 16 Emax [lx] 50 u0 0.515 Emin / Emax 0.313 Page 32 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Table (E) 6.417 47 44 38 31 25 21 18 18 18 21 5.250 50 46 39 31 24 20 18 17 18 20 4.083 50 47 40 32 25 20 18 17 18 20 2.917 49 45 39 32 24 20 17 17 17 20 1.750 46 43 37 31 24 20 17 16 17 20 0.583 41 39 34 29 23 19 17 16 17 19 m 1.500 4.500 7.500 10.500 13.500 16.500 19.500 22.500 25.500 28.500 Attention: The coordinates refer to the image above. Values in Lux. Grid: 15 x 6 Points Eav [lx] 31 Emin [lx] 16 Emax [lx] 50 u0 0.515 Emin / Emax 0.313 Page 33 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Table (E) 6.417 25 31 38 44 47 5.250 24 31 39 46 50 4.083 25 32 40 47 50 2.917 24 32 39 45 49 1.750 24 31 37 43 46 0.583 23 29 34 39 41 m 31.500 34.500 37.500 40.500 43.500 Attention: The coordinates refer to the image above. Values in Lux. Grid: 15 x 6 Points Eav [lx] 31 Emin [lx] 16 Emax [lx] 50 u0 0.515 Emin / Emax 0.313 Page 34 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Observer 1 / Isolines (L) Values in Candela/m², Scale 1 : 365 Grid: 15 x 6 Points Observer Position: (-60.000 m, 1.750 m, 1.500 m) tarmac: R3, q0: 0.070 Calculated values: Required values according to class ME1: Lav [cd/m²] 2.35 U0 0.58 Ul 0.79 TI [%] 8 ≥ 2.00 ≥ 0.40 ≥ 0.70 ≤ 10 Fulfilled/Not fulfilled: Page 35 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 1 / Observer 2 / Isolines (L) Values in Candela/m², Scale 1 : 365 Grid: 15 x 6 Points Observer Position: (-60.000 m, 5.250 m, 1.500 m) tarmac: R3, q0: 0.070 Calculated values: Required values according to class ME1: Lav [cd/m²] 2.14 U0 0.57 Ul 0.86 TI [%] 10 ≥ 2.00 ≥ 0.40 ≥ 0.70 ≤ 10 Fulfilled/Not fulfilled: Page 36 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Results overview Light loss factor: 0.80 Scale 1:365 Grid: 15 x 6 Points Accompanying Street Elements: Roadway 2. tarmac: R3, q0: 0.070 (All lighting performance requirements are met.) Selected Lighting Class: ME1 Calculated values: Required values according to class: Fulfilled/Not fulfilled: Lav [cd/m²] 2.14 ≥ 2.00 U0 0.57 ≥ 0.40 Ul 0.79 ≥ 0.70 TI [%] 10 ≤ 10 SR 0.84 ≥ 0.50 Assigned observer (2 Pieces): No. 1 2 Observer Position [m] Observer 3 Observer 4 (-60.000, 13.750, 1.500) (-60.000, 17.250, 1.500) Lav [cd/m²] U0 Ul TI [%] 2.14 2.35 0.57 0.58 0.86 0.79 10 8 Page 37 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Isolines (E) Values in Lux, Scale 1 : 365 Grid: 15 x 6 Points Eav [lx] 31 Emin [lx] 16 Emax [lx] 50 u0 0.515 Emin / Emax 0.313 Page 38 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Greyscale (E) Scale 1 : 365 Grid: 15 x 6 Points Eav [lx] 31 Emin [lx] 16 Emax [lx] 50 u0 0.515 Emin / Emax 0.313 Page 39 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Value Chart (E) Values in Lux, Scale 1 : 365 Not all calculated values could be displayed. Grid: 15 x 6 Points Eav [lx] 31 Emin [lx] 16 Emax [lx] 50 u0 0.515 Emin / Emax 0.313 Page 40 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Table (E) 6.417 41 39 34 29 23 19 17 16 17 19 5.250 46 43 37 31 24 20 17 16 17 20 4.083 49 45 39 32 24 20 17 17 17 20 2.917 50 47 40 32 25 20 18 17 18 20 1.750 50 46 39 31 24 20 18 17 18 20 0.583 47 44 38 31 25 21 18 18 18 21 m 1.500 4.500 7.500 10.500 13.500 16.500 19.500 22.500 25.500 28.500 Attention: The coordinates refer to the image above. Values in Lux. Grid: 15 x 6 Points Eav [lx] 31 Emin [lx] 16 Emax [lx] 50 u0 0.515 Emin / Emax 0.313 Page 41 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Table (E) 6.417 23 29 34 39 41 5.250 24 31 37 43 46 4.083 24 32 39 45 49 2.917 25 32 40 47 50 1.750 24 31 39 46 50 0.583 25 31 38 44 47 m 31.500 34.500 37.500 40.500 43.500 Attention: The coordinates refer to the image above. Values in Lux. Grid: 15 x 6 Points Eav [lx] 31 Emin [lx] 16 Emax [lx] 50 u0 0.515 Emin / Emax 0.313 Page 42 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Observer 3 / Isolines (L) Values in Candela/m², Scale 1 : 365 Grid: 15 x 6 Points Observer Position: (-60.000 m, 13.750 m, 1.500 m) tarmac: R3, q0: 0.070 Calculated values: Required values according to class ME1: Lav [cd/m²] 2.14 U0 0.57 Ul 0.86 TI [%] 10 ≥ 2.00 ≥ 0.40 ≥ 0.70 ≤ 10 Fulfilled/Not fulfilled: Page 43 Senai Road Lighting Simulation 27.10.2021 Operator Telephone Fax e-Mail Street 2 (2 roadways, 2 Lanes/roadways ) / Valuation Field Roadway 2 / Observer 4 / Isolines (L) Values in Candela/m², Scale 1 : 365 Grid: 15 x 6 Points Observer Position: (-60.000 m, 17.250 m, 1.500 m) tarmac: R3, q0: 0.070 Calculated values: Required values according to class ME1: Lav [cd/m²] 2.35 U0 0.58 Ul 0.79 TI [%] 8 ≥ 2.00 ≥ 0.40 ≥ 0.70 ≤ 10 Fulfilled/Not fulfilled: Page 44