REV.
DATE
ENTRY
APPR.
"P" LEVEL CONFIG CODES
"F" LEVEL CONFIG CODES
OPTION CLASS
DRN.
DESCRIPTION
OPTION CLASS
INFO
ENTRY
INFO
POLE ORIENTATION
"A"
**NOTE: ALL HANDHOLES TO
HAVE HOOKS INSIDE TOP AND
BOTTOM
TOP VIEW
GIANT EMBEDDED SQUARE POLES
ALTERNATE DESIGN
TOP MOUNT DETAIL
1.
2.
3.
4.
5.
6.
7.
MIX (241N): WHITE-WHITE, MOLD FINISH WITH NO COATING.
ASTM C-150 TYPE I WHITE CEMENT.
f'c @ 28 DAYS = 7,000 PSI, USING SPUN CYLINDER TEST.
f'c @ 28 DAYS = 5,000 PSI, USING ASTM C-31 CYLINDER TEST.
POLES MANUFACTURED PER ASTM C-1089-13 SPECIFICATIONS.
PROTECTIVE COAT EXPOSED P.C. WIRES AT POLE ENDS.
MODFE: POLE BOTTOM PREPARATION FOR FREEZING OR CORROSIVE COASTAL ENVIRONMENTS; SEE
DOCUMENTATION.
8. MODDCI CORROSION INHIBITOR MIX MODIFICATION.
9. DUE TO THE NATURE & CHARACTERISTICS OF CONCRETE MANUFACTURING, SIDE MOUNT SPACING
DIMENSIONS CAN ONLY BE TAKEN TO THE NEAREST 1/8".
10. THE DOUBLE 5' OR 8' BOLTED ON STEEL ARM ASSEMBLY AT 29' AG (NOT TO EXCEED 1.91 SQ. FT. EPA,
31 LBS. EACH) DEPICTED ON THIS DRAWING IS DESIGNED TO WITHSTAND THE LOADS IMPARTED BY
HOLDING A SINGLE LUMINAIRE AT 31' AG (NOT TO EXCEED 3.3 SQ. FT. EPA, 75 LBS. EACH); THE POLE
DEPICTED ON THIS DRAWING IS DESIGNED TO WITHSTAND THE LOADS IMPARTED BY THE LMA AND
LUMINAIRE AS WELL AS (1) METER AT 5' AG (NOT TO EXCEED 1.05 SQ. FT. EPA, 15 LBS. EACH), (2) 36" X
60" BANNER CENTERED AT 19'-6" AG (NOT TO EXCEED 18 SQ. FT. EPA, 20 LBS. EACH), (1) DISCONNECT
AT 9' AG (NOT TO EXCEED 1.37 SQ. FT. EPA, 20 LBS. EACH), (1) SIDEMOUNT SHROUD UNIT WITH RADIOS
(NOT TO EXCEED 7.56 SQ. FT. EPA, 66 LBS. COMPLETE), HOLDING (1) OMNI CANISTER ANTENNA AT 37'-7"
AG (NOT TO EXCEED 2.43 SQ. FT. EPA, 15 LBS.) & 4X RADIO POLE TOP SHROUD (NOT TO EXCEED 1.7 SQ.
FT. EPA, 100 LBS. FILLED) AS DESIGNED PER THE ASCE7-10 USING A 115 MPH WIND ZONE (3-SECOND
GUST) CRITERIA. PLEASE CONTACT & ADVISE MANUFACTURER IF THE INTENDED LOADING EXCEEDS
THESE VALUES.
11.CUSTOMER TO ENSURE COMPLIANCE TO NEC.
CL
NOTES:
POLE SECTION
APPROVED BY
DATE
MEMPHIS SMALL CELL / AT&T
MEMPHIS, TN
GEQX12.2SPL POLE WITH DOUBLE 5' OR 8' ARMS
49-29
COMPLIANCE TO ANY CODE NOT EXPLICITLY LISTED ON THIS DRAWING IS NOT GUARANTEED.
PLEASE CONTACT NATIONAL OILWELL VARCO IF YOU HAVE SPECIFIC CODE REQUIREMENTS.
THIS DOCUMENT CONTAINS INFORMATION WHICH IS PROPRIETARY TO NATIONAL OILWELL VARCO. IT SHALL NOT BE
REPRODUCED, USED OR DISCLOSED TO ANYONE WITHOUT THE PRIOR WRITTEN PERMISSION OF NATIONAL OILWELL VARCO.
DETAIL "A"
signed by Wesley
Wesley Brian Digitally
Brian Myers
Date: 2020.08.07
Myers
09:18:11 -05'00'