MPM4809TD Level Transmitter Introduction MPM4809TD Level Transmitter is a submersible piezoresistive level measuring instrument with all seal construction. High stable and reliable piezoresistive pressure sensor and high-precision circuit chosen. Whole temperature range of digital temperature compensation is done. Specialized cable is sealed with the housing. The air vented tube is inside of the cable. MPM4809TD can be used for a long time in the liquid that is compatible with transmitter housing material. MPM4809TD Level Transmitter is small in size, light in weight, good stability in long term use. Customers do not need to adjust themselves. It can be used for level measurement and control in oil, chemical industry, medicine, metallurgy, power plant, mine, city water drainage and hydrology. Features • Integrated construction, without outer adjustment • Reversed polarity protection • Protection grade of sensor housing is IP68,protection grade of PD140 protection device is IP65. • High reliable, stable in long term use Specification Measuring range 0~2m Diesel Oil(proportion: 0.84~0.86) Overpressure 2 times of FS(variation <0.3%) Power supply 8~28V DC Output 4~20mA DC(2-wire) Accuracy ① Total error ② Stability error 0.5%FS 1%(-10~80℃ ) 0.5%FS/Year Working Temperature range -10~80℃ Storage Temperature range -20~80℃ Load resistance ≤(U-8)/0.02Ω Response time ≤3s Insulation ≥100MΩ/100V Protection IP68 Relative Humidity 10%~95%RH Vibration effect 3g(0~150Hz) Life Intrinsic Explosion proof 10×106times full scale Exia II BT6 Ga Note: ① Testing is under normal temperature (refer to 20℃ ± 5℃ ); non-linearity. Accuracy is rms root-mean-square of non-linearity, repeatability, hysteresis. ② Within the temperature range, it includes total index of non-linearity, repeatability, hysteresis, zero drift, sensitivity drift, zero short-term stability etc. www.microsensorcorp.com V3.1.1 MPM4809TD Level Transmitter Connected Control Equipment Connected Transmitter Construction material Outline Construction (Unit: mm) • Housing: Stainless Steel 316L • Cable: Polyurethane 2.Out:Blackcable wire with air vented tube • 1.+Vcc:Red 2.Out:Black wire wire Diaphragm: Stainless Steel 316L • Connection Device: PBT Engineering Plastics PBT Electrical Connection 1 ~130 +VCC OUT monitoring device R U ~130 3.+Vcc:Red wire 3.+Vcc:Red wire wire 4.Out:Black OUT 4.Out:Black wire Connected to the ground Connected to the ground R OUT A sensor GND m 4 φ26 GND +Vcc 3 +Vcc 7 5 ~130 Connected to the ground Connected Transmitter Black Connected Transmitter 6 ~3000 ~3000 Electrical definition Control Equipment sensor connected to A 1 Connected ControlGNDEquipment Wire Connected Color Red Connected to the ground connected to A ~3000 Connected Control Equipment 3.+Vcc:Red wire 4.Out:Black wire 8 4.Out:Black wire 1.+Vcc:Red wire Connected Transmitter GND 2 3.+Vcc:Red wire 2.Out:Black wire 1.+Vcc:Red wire shielding wire shielding wire 6 7 φ26 4 φ26 1 35 Control Equipment 71 50 26 16 OUT R OUT shielding wire shielding wire 2 5 monitoring device monitoring3 device U U R 10 Argon arc welded 12 11 9 8 7 6 71 50 19 38 sensor sensor Connected SW12 MPM4809TDLever Transmitter 71 54 ~3000 +Vcc +Vcc 85 2.Out:Black wire 1.+Vcc:Red wire 10 R35 9 3 SW12 14 Nylon GND hose connection components 2 1 19 12 13 4 10 11 38 5 Connected Transmitter Argon arc welding Transmitter cable Connected to the ground 71 71 54 54 5 4 sensor 9 35 OUT 35 9 R35 device monitoring 71 50 26 71 16 50 26 16 +Vcc 38 SW12 SW12 11 3 1938 2 10 19 1 φ26 10 ansmitter cable R Argon arc weldin 12 13 14 Nylon 85 7 6 85 3.+Vcc:Red wire 8 4.Out:Black wire ~130 35 10 10 02 U 8 7 6 shielding wire PD140 Lightning Protection Device Argon arc welding 5 Argon arc welding 11 12 13 14 www.microsensorcorp.com V3.1.1 11 12 Transmitter 13 14 4 cable Nylon hose connection components R35 Nylon hose connection components MPM4809TD Level Transmitter Order Guide MPM4809TD Lever transmitter range [0~2 m Diesel] L L: cable length, when choosing, suggest L - X = (1 ~ 2) m Code E Output signal 4~20mADC Code 24 Structure material Diaphragm Connection Housing 316L SS 316L SS 316LSS Code Others Yd PD140 Lightning Protection device F MPM4809TD [0~2m diesel] 3 E 24 *Flange installation assembly FB *Flange plate installation ZH *Rack installation assembly W *Bent pipe installation components YdFB whole spec. Notes 1.Measured media should be compatible with transmitter material, and the density of the measured media should be clearly indicated (except water). 2. It uses Polyurethane cable. 3. Cable length is as per the requirement of clients. 4. If clients has special requirement, please contact us. www.microsensorcorp.com V3.1.1 03 04 1 MPM4809TD Level Transmitter Appendix 3 Flange installation assembly diagram: 10 85 12 10 11 Argon arc welded 8 19 38 Bent pipe installation components: Exhaust pipe installation 71 50 26 16 Flange installation 2 2 5 71 54 9 8 7 6 5 1 ~3000 Transmitter cable 1 GND 3 Type O ring ( 28×2.65) 4 6 connected to A connected to A 7 5 1 1 6 3 1 MPM4809TD Level Transmitter4 7 6 2 4 3 PD140 Lightning Protection Device 4 Permanent magnet absorbing installation 7 8 13mm, shielding wire 7 Flange bushing 8 Welding bend component 9 Lock line seat 10 Rubber ring 11 Locking ring 71 54 Nylon hose connection components SW12 installation: 35 1 A cable assembly Grounding 5 6 R OUT sensor(cylindrical Gasket 16.5mm, inner circle thickness 1.4mm) 12 Flange mounting kit monitoring device Type O ring ( 28×1. 8) U 38 3 φ26 Flange set +Vcc 5 A M30×1nut Tank flange Connected to the ground 85 4 3.+Vcc:Red wire 4.Out:Black wire 2 ~130 Connected Transmitter 1 8 5 4 2 1 3 7 6 2 2 Connected Control Equipment 10 8 6 3 71 50 26 16 1 2 4 19 Argon arc welding connected connected to A 12 13 14 to A Nylon hose connection components 2.Out:Black wire 1.+Vcc:Red wire 2 Transmitter specialized cable 5 5 15m signal cable 3 Argon arc welding 12 13 14 Nylon hose connection components 11 7 9 R35 Tr 10 8 Bracket mounting kit Rack installation assembly diagram: 6 Argon arc welded 10 11 12 7 7 6 5 4 Transmitter cable 1 2 3 4 9 1 1 8 7 6 2 5 5 4 3 3 2 1 Transmitter cable 1 Stainless steel clip 10 11 Argon arc welded 2 Bracket cable saddle 3 Rack support arm 4 M3 9 bolt 5 8 7 6 6 7 4 5 3 M3 nut Steel cable Air-vented tube 12 M30x1 nut 2 fuel tank 3 Sealed gasket 4 flange plate 5 Enclosed tonsil loose core rivet 6 O ring( 28x2.65) 7 Flange cover 8 10 O ring ( 28x1.8) Sealed gasket (External circle 16.5, internal circle 13, thickness 1.4 Flange center tube 9 11 Welded bent pipe components 12 Cable locker base 13 Rubber ring 14 Lines seat www.microsensorcorp.com V3.1.1 2 1