Uploaded by Alex

LR-18-0042

advertisement
Layout Recommendation
LR-18-0042.DOCX
RF_35/05.10/6.0
Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG
SMP
Draft
Date
Approved
Date
S. Sevskiy
26.04.18
T. Kaubisch
27.04.18
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Rev.
Engineering change number
Tel. : +49 8684 18-0
Fax : +49 8684 18-499
Email : info@rosenberger.de
Name
Date
Page
1/4
Layout Recommendation
SMP
LR-18-0042.DOCX
RF_35/05.10/6.0
Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG
Layer stackup
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Fax : +49 8684 18-499
Email : info@rosenberger.de
Page
2/4
Layout Recommendation
SMP
LR-18-0042.DOCX
RF_35/05.10/6.0
Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG
Drawings
Notes:
- all dimensions are in mm, unless otherwise stated
- all via diameters are finished inner diameters (drill diameters are assumed to be 0.1mm larger)
- see also “Technical Data Sheet” for other dimensions
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Fax : +49 8684 18-499
Email : info@rosenberger.de
Page
3/4
Layout Recommendation
SMP
LR-18-0042.DOCX
RF_35/05.10/6.0
Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG
Simulation results
Note:
Presented data are generated by 3-D Simulation and are not evaluated by practical tests. Due to
simulation uncertainties and eventual deviations of the model from the realised application regarding
boundary conditions, Rosenberger cannot guarantee the presented performance.
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Fax : +49 8684 18-499
Email : info@rosenberger.de
Page
4/4
Download