DC Input, Field Configurable Limit Alarms - AP1080/1090
Action Pak models AP1080 single setpoint and AP1090 dual setpoint limit alarms offer flexible, wide-ranging DC input
capability. Voltage spans from 10mV to 200 volts and current spans from 1mA to 100mA can be field configured.
Bipolar inputs are also accepted. Both models offer configurable latching, failsafe and HI/LO operation. The AP1080
and AP1090 also include 0.25%-50% adjustable deadbands and selectable 120/240VAC operation.
Diagnostic LED
Models AP1080-2000 and AP1090-2000 are equipped with dual function diagnostic LED. The green center LED
indicates line power and input signal status. Active line power is indicated by an illuminated LED. If the center LED is
off, check line power and the wiring connection. If the input signal is above 100% full scale, the LED will flash at
approximately 8Hz. Below 0%, the flash rate is approximately 4Hz.
FEATURES:
Operation
●
http://www.eurotherm.com/products/signal-conditioning/action/actionpak/limit-alarms/ap1080-1090/?locale=en_US (1 of 5) [4/30/2010 2:25:02 PM]
Selectable 120/240VAC Operation (9 to 30 VDC Available)
Limit Alarms - AC Powered - Action Pak - DC Input, Field Configurable Limit Alarms - 1080/1090
The field configurable AP1080 and AP1090 limit alarm setpoints can be configured for HI, LO, latching or failsafe trip
operation. Non-latching HI and LO setpoints have respective HI and LO deadbands. In a tripped condition, the setpoint
is exceeded and the appropriate red LED will illuminate. The trip will reset only when the process falls below the HI
deadband or rise above the LO deadband. To reset a latched setpoint the signal must be in the safe region and the line
power turned off for at least 5 seconds. For proper deadband operation, a HI setpoint must always be set above a Lo
setpoint.
●
Field Configurable Input Ranges for DC Voltage and Current
●
Setpoint(s)Programmable HI or LO
●
Exclusive“Dynamic Deadband” Prevents False Trips
●
Selectable Failsafe/Latching Operation
MORE INFO:
Calibration
Note: To maximize thermal stability, final calibration should be performed in the operating installation, allowing
approximately 1 - 2 hours for warmup and thermal equilibrium of the system.
Setpoint: Set deadband at its minimum (about 20 turns Counter Clockwise) before adjusting the setpoint. With the
specified trip voltage or current input applied, adjust setpoint until the relay trips. For HI trip calibration, start with the
setpoint above the desired trip. For LO trip calibration, start below the desired trip.
●
Diagnostic LED
●
Calibration
●
Specifications
●
Ordering Information
Deadband: Set deadband to its minimum (about 20 turns Counter Clockwise). Set setpoint to desired trip. Adjust
voltage/current input until relay trips. Readjust deadband to 50% (20 turns CW). Set voltage/current input to
desired deadband position. Slowly adjust deadband until relay untrips.
TECHNICAL SPECIFICATION ( AP1080-2000/AP1090-2000)
Input
Repeatability (constant temp):
Ordering Information
Voltage Input:
Specify:
1. Model:
●
Range: 10mV to 200V
●
Impedance: >100K Ohmns
●
Overvoltage: Intermittent, 400Vrms Continuous, 264 Vrms
●
>50mV/5mA: .1% of full scale
●
<50mV/5mA: .2% of full scale
1080-2000-1 /
120V AC powered, single trip/dual trip limi
1090-2000-1
1080-2000-1-P /
-P = Ten turn top mounted clock face dial
Stability
1090-2000-1-P
-P = Ten turn top mounted clock face dial
1080-2000-1-PU /
Line Voltage: ± .01%, max.
-U = Conformal coating
1090-2000-1-PU
Temperature:
± .05% of full scale/°C, max.
1080-2000-2
/
-2 = 240V AC powered
1090-2000-2
1080-2000-2-U /
-2 = 240V AC powered,
-U = Conformal coating
1090-2000-2-U
Common Mode
1080-2000-D
/ Rejection
-D = 24V DC powered
1090-2000-D
DC to 60Hz: 120dB
1080-2000-D-P
/
-D = 24V DC powered
-P = Ten turn top mounted clock face dial
1090-2000-D-P
1080-2000-D-U /
-D = 24V DC powered
-U = Conformal coating
1090-2000-D-U
Isolation
1080-2001-1
/
-2001 = Latching
1090-2001-1
1000 VDC between contacts, input and power
1080-2004-1 /
-2004 = 35mS response time
1090-2004-1
1080-2004-D /
-D =24V DC powered
1090-2004-D
●
●
Current Input:
●
Full Scale Range: 1mA to 100mA
●
Impedance: 20 Ohms, typical
●
Overcurrent: 200mA, max
●
Overvoltage: 60VDC
●
Common Mode (Input toGround): 1500VDC, max
LED Indications
●
Input Range (Green)
ESD Susceptibility
http://www.eurotherm.com/products/signal-conditioning/action/actionpak/limit-alarms/ap1080-1090/?locale=en_US (2 of 5) [4/30/2010 2:25:02 PM]
Limit Alarms - AC Powered - Action Pak - DC Input, Field Configurable Limit Alarms - 1080/1090
❍
>100% input: 8Hz flash
●
❍
<0% input: 4Hz flash
Setpoint (Red) Tripped: Solid red
●
Safe: Off
-D - 24V DC powered
top mounted clock face dial
-2005 = Higher input limit (300V DC)
1080-2004-D-P
Meets IEC 801-2, Level
2 (4KV)
-P =
Ten turn
1080-2005-1
1080-2005-D /
-D = 24V DC powered
1090-2005-D
Humidity
(Non-Condensing)
-2005 = Higher input limit (300V DC)
1080-2005-D
-2007 = Adjustable response time (.5 - 3 m
1080-2007-1
Operating: 15 to 95% (@ 45°C)
-2008 = Higher input limit (500V DC)
1080-2008-1
Soak: 90% for-5001
24 hours
(@ 45°C)
= External
wires for 20K external se
1090-5001-1
pot
-D = 24V DC powered
1080-5001-D
●
Limit Differential
●
●
>50mV/5mA: .25% to 50% of span
●
<50mV/5mA: 1% to 50% of span
Temperature
Range
2. Optional Custom Factory Calibration
(specify
C620, see required settings under "Calibration
3. Accessories.
Response Time: Dynamic Deadband:
Relay status will change when proper setpoint/process condition exists uninterrupted for 100ms
Normal Mode (analog filtering)
Accessories
●
Operating:
●
Storage:
-15 to 60°C (5 to 140°F)
-25 to 70°C (-13 to 158°F)
All AP series need to mount to either an 8 or 11 pin base which connects to a standard TS35
or to a channel track mount.
M801-0000
Retaining Spring
Power
M011-A
11 pin Track Mount Socket
M004-0000
4
ft Long
Channel
Track
Consumption: 2W
typical,
5W max
MD11-0000
11 pin DIN Mount Socket
●
<250ms, (10-90%)
Downloads
●
Standard: selectable 120/240VAC, ±10%, 50-60Hz
●
Optional: 9 to 30VDC, inverter isolated
Setpoint: Effectivity:
Setpoints are adjustable over 100% of the selected input span.
Weight
AP1080: .46lbs; AP1090: .62lbs
Agency Approvals
Brochure & Specification Sheet
●
●
Action Instruments Brochure HA136737U001 (1.35 MB)
Action Instruments Product Handbook (Volume 18) (30.14 MB)
User Documentation (download requires registration)
●
Action PAK AP1080 & AP1090 DC Input, Field Configurable Limit Alarms Specification Sheet [721-0479-0 (338 KB)
http://www.eurotherm.com/products/signal-conditioning/action/actionpak/limit-alarms/ap1080-1090/?locale=en_US (3 of 5) [4/30/2010 2:25:02 PM]
●
CSA certified per standard C22.2, No. M1982.
●
UL recognized per standard UL508.
Limit Alarms - AC Powered - Action Pak - DC Input, Field Configurable Limit Alarms - 1080/1090
Get a Quote
» Indicates required fields
Request for Quote
Your Details
Salutation
First Name »
Last Name »
Company Details
Company Name »
Job Title
Industry » Select an Item
Address 1 »
Address 2
City »
Zip / Postal Code »
State / Province Code »
*Leave State / Province Code blank if not applicable*
Country » Select an Item
Contact Details
Phone »
Email »
How did you hear about us? » Select an Item
Product Requirements
Quantity »
Application Description
Comments
Submit
Reset
Get Support
Visit the Eurotherm Support site
Do you have feedback on our website? Tell us what you think
Text Only | Accessibility | Site Map | Text size: bigger / normal / smaller
http://www.eurotherm.com/products/signal-conditioning/action/actionpak/limit-alarms/ap1080-1090/?locale=en_US (4 of 5) [4/30/2010 2:25:02 PM]
Limit Alarms - AC Powered - Action Pak - DC Input, Field Configurable Limit Alarms - 1080/1090
©2010 Eurotherm | Legal Information | Privacy Policy | Trading Disclosure
Quick links: Temperature Controllers | Thermocouples | Graphic Recorders | Indicators | Power Control | Drives | PAC
Global sites: USA | UK | India | Spain | Korea | China | Italy | Sweden | France | Germany | Netherlands
http://www.eurotherm.com/products/signal-conditioning/action/actionpak/limit-alarms/ap1080-1090/?locale=en_US (5 of 5) [4/30/2010 2:25:02 PM]
Download