A B C D BRUCIATORI A GAS PROGRESSIVI PROGRESSIVE GAS BURNERS BRULEURS GAZ PROGRESSIVES QUEMADOR DE GAS PROGRESIVOS BLU 3000.1 PR BLU 4000.1 PR LB1616 27.06.2006 B LB 1616 BLU 3000.1 PR - BLU 4000.1 PR BLU 3000.1 PR/MD BLU 4000.1 PR/MD Technical data Thermal power max. kW 3000 3900 kcal/h 2.586.000 3.362.000 kW 630 875 kcal/h 543.100 754.300 mbar 40÷300 40÷300 mbar 37÷150 37÷150 V 230 / 400 230 / 400 kW 5,5 7,5 N° 2800 2800 P.c.i. Natural gas = 35,9 Mj / Nm3 = 8.600 kcal / Nm3 P.c.i. GPL 22.260 kcal / Nm3 Thermal power min. Natural gas pressure LPG pressure Voltage , 50 Hz Motor Rpm Fuel : OPERATING RANGE OF THE BURNERS mbar 16 12 10 U BL 8 6 .1 00 40 combustion chamber pressure 14 BLU 3000.1 4 2 0 500 1000 500 1500 1500 1000 2000 2000 2500 2500 3500 kcal/h x 1000 3000 3000 4000 kW 3500 capacity OVERALL DIMENSIONS E A D - D1 B C I L F M 0 1 I 2 3 H N G O O MODELS A B C D Blu 3000.1 Blu 4000.1 941 941 448 448 493 493 330 365 D1 E F G H 530 780 290 466 280 565 780 320 466 280 D= Short head D1= Long head pag.8 I L M N O 315 315 315 315 M16 M16 195 195 250 250 LB 1616 BLU 3000.1 PR - BLU 4000.1 PR B CONNECTION TO THE GAS PIPELINE Once connected the burner to the gas pipeline, it is necessary to control that this last is perfectly sealed. Also verify that the chimney is not obstructed. Open the gas cock and carefully bleed the piping through the pressure gauge connector, then check the pressure value trough a suitable gauge. Power on the system and adjust the thermostats to the desired temperature. When thermostats close, the sealing control device runs a seal test of valves; at the end of the test the burner will be enabled to run the start-up sequence. ELECTRICAL CONNECTIONS All burners factory tested at 400 V 50 Hz three-phase for motors and 230 V 50 Hz monophase with neutral for auxiliary equipment. If mains supply is 230 V 50 Hz threephase withuot neutral, change position of connectors on burner as in fig. Protect burner supply line with safety fuses and any other devices required by safety standards obtaining in the country in question. BURNER START-UP Once connected the burner to the gas pipe make sure that there are no leakages. Air bleed the pipe through the pressure gauge fixing point and check the pressure with a pressure gauge . Turn the thermostats to the desired temperature. PRELIMINARY CHECKS - Before starting up the boiler check the following: - gas type and feed pressure; - gas valves closed; - the seals in the pipe fittings; - gas pipe breather and input pressure; - that the cable complies with the diagram and the phase and neutral wires correspond; - that the burner shuts down when the boiler thermostat opens;- the seal of the boiler furnace which prevents air from entering; - the seal on the flue-boiler pipe fitting; - the condition of the flue (sealed, free from blockage, etc ).If all these conditions are present, start the burner. The control device starts the motor to carry out prewashing of the combustion chamber. During this prewash period (about 30 seconds) the device checks that air pressure is correct via the air pressure switch. At the end, it supplies power to the transformer and opens the gas valves. The flame must be lit and stabilize within 3 seconds, which is the device's safety time limit. Check to ensure the flame is lit before placing any control instrument in the flue. Adjust and check the gas flow necessary for the boiler at the meter. Adjust the air flow according to the gas flow to obtain correct combustion. ADJUSTING THE COMBUSTION PROCESS CO2 LPG 11,7% CO <50 ppm 30 1,3 25 1,25 20 15 10 AIR FACTOR CO2 CO Natural Gas 9,6% <50 ppm AIR EXCESS (%) IMPORTANT: to obtain the right adjustment of the combustion and thermal capacity it is important to analyze the reducts of combustion with the aid of suitable instruments. The combustion and thermal capacity adjustment is done simultaneously, together with the analysis of the products of combustion, making sure that the measured values are suitable and that they comply with current safety standards. On this matter, please refer to the table and figure below. THESE OPERATIONS MUST BE DONE BY PROFESSIONALLY-QUALIFIED TECHNICIANS. 1,2 1,2 1,2 1,15 1,1 10 20 30 40 50 60 70 80 100 90 200 300 400 500 THERMAL POWER (kW) pag.9 600 800 1000 700 900 2000 3000 4000 5000 6000 B LB 1616 BLU 3000.1 PR - BLU 4000.1 PR LANDIS & STAEFA, Model LFL1.622 OPERATING CYCLE Ref. t1 t2 t3 t4 t5 t6 Description Duration Duration Waiting time for confirmation of air pressure 8” Preventilation time 66” Safety time 2” Pressurizing time 4” Time for enabling operation of the main gas valve on minimum capacity 10” Time for enabling operation of the main gas valve on maximum capacity Operating cycle in the event of Ciclo di funzionamento in mancanza di fiamma operating all'accensione ignition failureNormal cycle CicloNormal di funzionamento normale operating cycle t1 t2 t3 t1 t2 t3 Pressostato gas Gas manostat Motore ventilatore Fan motor Pressostato aria Air Switch 10” Trasformatore Ignition di transformer accensione t4 t4 Valvola gas Gas valve The control box starts the burner t5 t6 Consenso Min/max capacity potenza fan, to carry out the prepurging of min./max. enabling device the combustion chamber, and 100% Serranda aria min cheks the vent air pressure throuAir damper 0 gh the air pressure switch. At the Farfalla gas Gas damper end of prepurging, the ignition Rivelazione Flame detector di fiamma transformer cuts-in and generates Cut-out pilot lamp Spia di blocco a spark between the electrodes. At the same time the two gas valves open (Vs safety valve and Vl working valve). The total safety, in case of missed ignition or casual burner's flame-out, is granted by a ionisation probe which cuts-in and sets the burner shutdown within the safety time. In case of gas lack or a major pressure drop, the minimum air pressure switch shuts down the burner. LANDIS & STAEFA SQM 50.481A2 AIR DAMPER MOTOR Remove cover to gain access to the adjusting cams.The cams are to be adjusted through the suitable key provided for. Description: Cam VIII is never used I II III IV V VI VII VIII - High flame opening position adjusting cam (Air) Min. flame opening position adjusting cam (Air). Low flame opening position adjusting cam (Air) Not used cam Not used cam Not used cam Not used cam Not used cam pag.10 LB 1616 BLU 3000.1 PR - BLU 4000.1 PR B AIR ADJUSTMENT -+ Part. 1 Part. 3 -SELECTOR COMMUTATORE AUTO 0 + Part. 2 0 = operating bloccaggio elements degli apparati per ilin an intermediate locked funzionamento in una posizione intermadia position = operation funzionamento alla massima potenza on maximum capacity = operation funzionamento alla minima potenza on minimum capacity AUTO = automatic funzionamento automatico operation ADJUSTING THE MINIMUM CAPACITY OF THE BURNER – AIR and GAS Position the selector placed on the control panel on position 2 and proceed as follows: Adjust the minimum gas flow rate using a suitable wrench, turn the butterfly valve until you reach the correct gas flow, as established by analyzing the combustion process. ADJUSTING THE MAXIMUM CAPACITY OF THE GAS Position the selector, situated on the control panel, on position 1 and proceed as follows: Adjusting the maximum gas flow rate (see figure on solenoid valve adjustments) or adjust the gas pressure in the governor. ADJUSTING THE MAXIMUM AIR FLOW RATE Adjusting the maximum air flow rate (see figure, detail 2). Loosen the nut holding the air damper transmission rod; The correct air flow as established by analyzing the combustion process. ADJUSTING THE INTERMEDIATE BURNER CAPACITY Using the selector, start the servomotor (closing or opening) and position on 0 to stop the stroke; the adjustment is made as outlined below. Repeat the operation for the other cam points. Adjustment the intermediate gas flow rates (see figure, detail 3): - using a suitable Allen wrench, change the position of the cam guide blade; if you screw it down, the flow rate is reduced; if you unscrew it, the flow rate increases. CALCULATING THE BURNER CAPACITY To calculate the burner's capacity in kW, proceed as follows: Check the gas flow rate (in liters) on the counter and the time of the reading in seconds. e x f = kW Proceed with the calculation using the following : sec pag.11 f e sec G20 G30 G31 = = = = = Litres gas Time in second 34,02 116 88 B LB 1616 BLU 3000.1 PR - BLU 4000.1 PR COMBUSTION ADJUSTMENT WARNING: In order to have a correct combustion and thermal output adjustments, these must be carried out together with a combustion analysis, to be executed through suitable devices, taking care that the values are the correct ones and are in accordance with the local safety regulations. The adjustments must be carried out by qualified and skilled technicians authorised by Ecoflam S.p.A. FIRING HEAD SETTING - + IGNITION ELECTRODE Ignition electrode Elettrodo di accensione 7 mm 4 mm " " 7 mm Ionization probe Elettrodo di rivelazione ADJUSTMENT OF GAS MINIMUM PRESSURE SWITCH 45 40 35 25 30 N M 2,5 20 5 10 2,7 2,1 3,0 1,5 1,8 D 0,4 1,2 Unscrew screws A and B and remove cover C.- Set the pressure switch to the minimum by I turning regulator D to position 1. L - Start the burner and keep in low flame running, while checking that combustion is correct. Through a small cardboard, progressively obstruct the air intake until to obtain a CO2 increase of 0,5÷0,8% or else, if a pressure gauge is available, connected to pressure port E, until reaching a pressure drop of 1 mbar (10 mm of W.G.). - Slowly increase the adjustment value of the air C pressure switch until to have the burner lockout. Remove the obstruction from the air intake, screw on the cover C and start the burner by pressing the control box rearm button. A 15 2,4 ADJUSTMENT OF THE AIR PRESSURE SWITCH 50 Unscrew off and remove cover M. - Set regulator N to a value equal to 60% of gas nominal feed pressure (i.e. for nat. gas nom. pressure = 20 mbar, set regulator to a value of 12 mbar; for L.P.G. nom. pressure of G30/G31- 30/37 mbar, set regulator to a value of 18 mbar).Screw up cover M 0,6 0,9 H E G B Note: The pressure measured at pressure port E must be within the limits of the pressure switch working range. If not, loose the locking nut of screw F and gradually turn the same: clockwise to reduce the pressure; counterclockwise to increase. At the end tighten the locking nut. pag.12 F LB 1616 BLU 3000.1 PR - BLU 4000.1 PR B IONIZATION CURRENT min. 6 µA 24 LANDIS LFL1.622 Microamperometro Microammeter fondo scala 50 µA 50 µA end of scale The ionization current is checked by inserting a microammeter with an end of scale of 50 µA (d.c.) in series with the ionization probe. A faulty position of the electrode can lead to a reduction in the ionization current and cause a safety cut-out of the burner due to a flame detection failure. In this case, check the position of the electrode, its electric connection and the earthing of the burner. FIRING HEAD DISASSEMBLY DESCRIPTION OF THE CONTROL PANEL OF THE BURNER F AUTO 0 I 0 A B C D E A - selector : 0 = operating elements locked in an intermediate position 1 = operation on maximum capacity 2 = operation on minimum capacity 3 = automatic operation B - working lamp C - termal lock-out lamp D - fuse E - main switch I / O F - reset key pag.13 COMUNICARE A TERZI IL CONTENUTO DEL PRESENTE. A TERMINE DI LEGGE E' VIETATO RIPRODURRE O PROPRIETA' RISERVATA DELLA DITTA ECOFLAM S.p.A. E D C SOST.DA SOST.IL IND.MOD. 00 DATA-FIRMA MV FMV KMV N T S R PE 230V 400V U R 3 V S W 50 Hz 400V FMV HLBT T NO 98 97 M DATA pag.26 01 FIRMA R S T N 2 3 4 5 6 CONTROLLATO DISEGNATO DESCRIZIONE MODIFICA Q 1 04 02 7 HLB 8 10 T STAB P 11 12 13 96 95 27-03-2006 9 FMV HLF SAL FU LINE LOAD 03 Z T T STS T STC SPA P P P YVG P1 HLF YVGS 04 L1 L1 0 1 2 P1 SAMA UFF.TECNICO-SETTORE ELETTRICO TV N N T1 T1 S3 S3 BROWN ER 05 FIRMA 07 3 05 LANDIS LFL 1.333-LFL 1.622 06 DUNGS VPS 504 ER 09 08 BEM06164 09 pos 0: FERMO / STOP pos 1: ALTA FIAMMA/HIGH FLAME/2meALLURE/ALTA LLAMA pos 2: BASSA FIAMMA/LOW FLAME/1re ALLURE/BAJA LLAMA pos 3: AUTOMATICO/AUTOMATIC/AUTOMATIQUE/AUTOMATICO CODICE 1 2 Femmina 10 COMMUTATORE MANUALE-AUTOMATICO SWITCH MANUAL-AUTOMATIC INTERRRUPTEUR MANUEL-AUTOMATIQUE CONMUTADOR MANUAL-AUTOMATICO 11 12 7 LANDIS SQM 50.481A2 CONTROLLO DI TENUTA SIST. RIVELAZ. 0 SAMA 8 9 4 1 Maschio 12 9 6 3 APPARECCHIATURA P 5 6 2 11 10 3 8 7 2 5 1 4 MOTORIDUTTORE T SPGmin LANDIS SQM 50.481A2 08 BLU 3000.1 - 4000.1 - 5000.1 - 6000.1 PR L1 KA M 07 N 11 1 21 12 2 22 13 3 23 14 4 24 15 5 25 16 6 26 17 7 27 1 06 DENOMINAZIONE T8 T7 T6 B5 N DUNGS VPS 504 T2 T2 S.p.A. N 3 BLUE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 31 32 LANDIS LFL 1.333 - LFL 1.622 03 BLACK 02 DATA B 01 YELLOW-GREEN A 00 PAGINA DI IND.MODIFICA 1/2 E D C B A ABCD LB 1616 BLU 3000.1 PR - BLU 4000.1 PR COMUNICARE A TERZI IL CONTENUTO DEL PRESENTE. A TERMINE DI LEGGE E' VIETATO RIPRODURRE O PROPRIETA' RISERVATA DELLA DITTA ECOFLAM S.p.A. E D C B A TERMOSTATO DI ALTA-BASSA FIAMMA HIGH-LOW FLAME THERMOSTAT THERMOSTAT GRANDE-PETIRE ALLURE TERMOSTATO DE ALTA-BAJA LLAMA STAB SOST.DA SOST.IL 00 DATA-FIRMA COMMUTATORE MANUALE-AUTOMATICO SWITCH (MANUAL-AUTOMATIC)) INTERRUPTEUR MANUEL-AUTOMATIQUE CONMUTADOR MANUAL-AUTOMATICO SAMA IND.MOD. LAMPADA DI BLOCCO TERMICO THERMAL LOCK-OUT LAMP LAMPE DE THERMAL DE SECURITE ESPIA DE BLOQUEO RELE TERMICO TERMOSTATO DI SICUREZZA SAFETY THERMOSTAT THERMOSTAT DE SECURITE TERMOSTATO DE SEGURIDAD STS HLBT TERMOSTATO CALDAIA BOILER THERMOSTAT THERMOSTAT CHAUDIERE TERMOSTATO CALDERA STC INTERRUTTORE DI LINEA WORKING SWITCH INTERRUPTEUR DE LIGNE INTERRUPTOR DE LINEA SAL PRESSOSTATO ARIA AIR PRESSURE SWITCH PRESSOSTAT AIR PRESOSTATO AIRE CONTATTORE MOTORE VENTILATORE REMOTE CONTROL SWITCH (FAN MOTOR) CONTACTEUR MOTEUR VENTILATEUR TELERRUPTOR MOTOR VENTILATOR KMV SPA LAMPADA DI BLOCCO LOCK-OUT LAMP LAMPE DE SECURITE ESPIA DE BLOQUEO FIRMA 01 RELE' TERMICO MOTORE VENTILATORE MOTOR THERMAL RELAY (FAN MOTOR) RELAIS THERMIQUE MOTEUR VENTILATEUR RELE' TERMICO MOTOR VENTILADOR FMV HLB ELETTRODO DI RIVELAZIONE IONISATION PROBE ELECTRODE D'IONISATION ELECTRODO DE IONIZACION ER MOTORE VENTILATORE MOTOR FAN MUTEUR VENTILATEUR MOTOR VENTILADOR MV TRASFORMATORE IGNITION TRANSFORMER TRANSFORMATEUR D'ALLUMAGE TRANSFORMADOR FUSIBILE FUSE FUSIBLE FUSIBLE FU TV FILTRO ANTIDISTURBO ANTJAMMING FILTER FILTRE ANTIPARASITES FILTRO DE PROTECION ANTIDISTURBIO Z CONTROLLATO DISEGNATO DESCRIZIONE MODIFICA KA HLF 02 SPGmin YVGS YVG 27-03-2006 RELE' RELAY RELAIS RELE' LAMPADA DI FUNZIONAMENTO WORKING LAMP LAMPE DE FONCTIONNEMENT ESPIA DE FUNCIONAMIENTO PRESSOSTATO GAS DI MINIMA GAS PRESSURE SWITCH MIN PRESSOSTAT GAZ PRESSION MIN PRESOSTATO GAS DE MINIMA POT. 03 ELETTROVALVOLA GAS DI SICUREZZA EXTRA SAFETY GAS SOLENOID VALVE ELECTROVANNE GAZ DE SECURITE ELECTROVALVULA GAS DE SEGURIDAD ELETTROVALVOLA GAS DI PRIMA FIAMMA FIRST STAGE GAS SOLENOID VALVE ELECTROVANNE GAZ PETITE ALLURE ELECTROVALVULA GAS DE 1^ LLAMA FIRMA INTERRUTTORE GENERALE CON FUSIBILE MAIN SWITCH WITH FUSE INTERRUPTEUR GENERAL AVEC FUSIBLE INTERRUPTOR GENERAL CON FUSIBLE 04 UFF.TECNICO-SETTORE ELETTRICO S.p.A. P1 N T1 N N T1 T2 T2 S3 1 07 DUNGS VDK 200-A 13 14 S3 PREDISPOSICION CONTROL DE ESTANQUIDAD PREVU POUR LE CONTROLE D'ETANCHEITI PREDISPOSED LEKAGE CONTROL PREDISPOSIZIONE CONTROLLO DI TENUTA SIST. RIVELAZ. 3 08 P T P SPGmin T SPGmin 05 LANDIS LFL 1.333-1.622 APPARECCHIATURA 06 CONTROLLO DI TENUTA ER 08 CODICE BEM06164 LANDIS SQM 50.481A2 YVGS L1 P1 N 07 MOTORIDUTTORE P1 YVGS L1 YELLOW-GREEN BLU 3000.1 - 4000.1 - 5000.1 - 6000.1 PR YVG YVG P1 06 BLACK DENOMINAZIONE 05 BLUE Q 04 BROWN 03 BLUE 02 YELLOW-GREEN 01 BLACK 00 BROWN pag.27 DATA 09 09 PAGINA DI IND.MODIFICA 2/2 E D C B A LB 1616 BLU 3000.1 PR - BLU 4000.1 PR ABCD DATA 14 7 13 pag.28 18 21 20 19 17 16 0 I 0 AUTO ER FIND 39 23 36 0 I 0 AUTO RWF 40 PGM KIT MD 22 5 15 EXIT K6 6 1 4 3 38 9 8 35 10 24 25 27 26 33 Blu 3000.1- 4000.1 PR 6 11 12 29 28 30 31 32 34 37 ABCD LB 1616 BLU 3000.1 PR - BLU 4000.1 PR B N° 1 2 3 4 5 6 7 LB 1616 BLU 3000.1 PR - BLU 4000.1 PR DESCRIPTION - 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 - AIR PRESSURE SWITCH AIR INTAKE SET PLUG WIELAND COVER GLASS PEED WINDOM FRAME MOTOR FAN FAN SCOOP AIR CONVEYOR AIR INTAKE AIR INTAKE PIPE CONTROL BOX BASE CONTROL BOX IGNITION TRANSFORMER REMOTE CONTROL SWITCH BLU 3000.1 PR/MD BLU 4000.1 PR/MD Q120 GRPA100 E226 BFC09254/038 BFC02004 BFC02006 M128/017 BFV10304/001 BFC08254/001 GRCA320 BFS02208/201 A401 A113 T106/4 R617 R513 R1020 R1020/5 E1510 E802/2 R905 R711 Q120 GRPA100 E226 BFC09254/038 BFC02004 BFC02006 M129/017 BFV10304/001 BFC08059/001 BFC08256/001 GRCA320 BFS02208/201 A401 A113 T106/4 R616 R513/1 R1020 R1020/5 E1510 E802/2 R905 R711 E1102/27 BFE01057/1 BFE01057/2 BFT14015/101 BFT14015/201 BFA08020/101 BFA08020/201 BFT14016/001 BFD03020 BFT12113/2 BFT12113/5 E1102/27 BFE01057/1 BFE01057/2 BFT14015/101 BFT14015/201 BFA08020/101 BFA08020/201 BFT14016/001 BFD03020 BFT12113/3 BFT12113/5 BFB07023/103 BFB07023/203 BFG04051/1 S132/4 M212/91 GRSIL04/01 BFB07026/103 BFB07026/203 BFG04051/1 S132/4 M212/91 GRSIL04/01 E2490/5514 E2490/5514 code DUNGS LGW10 A2P 6 pin 5500 W 7500 W 320 X 150 LANDIS LANDIS LFL1.622 COFI 820 PM BF25.00 BF40.00 MOTOR THERMAL RELAY Lovato RF25 9-15 A Lovato RF25 14-23 A MAIN SWITCH cod.40100I1509 MANUAL / AUTOMATIC SELECTOR LAMP EL/N-SC4 Elettrospring FUSE SUPPORT FUSIT FH-B528 RELAY BASE FINDER 5532 RELAY FINDER 5532 IGNITION CABLE IONIZATION CABLE IGNITION ELECTRODE IONIZATION PROBE PIPE TC TL ROD TC TL FIRING HEAD FRONT DISC FRONT PIPE NATURAL GAS LPG INNER ASSEMBLY TC TL BLAST TUBE TC TL GASKET ANTIJAMMING FILTER AIR DAMPER MOTOR SQM50.481A2 SILENCER model MD MODULATING KIT LANDIS RWF 40 TC = SHORT HEAD TL = LONG HEAD pag.30 code