TFL 252 1 RLCL Product information Conductor Stranded, annealed tinned copper, flexible according to IEC 60228 class 5 Insulation Flame retardant TPE, black Concentric conductor Tinplated, bunched copper wires Jacket Flame retardant TPE, grey or black. Operating voltage Max 300 V DC Operating temperature Max 90 ºC Fire resistance IEC 60332-3-24 Cat C UL 1685, Vertical Tray Flame Test UL 1581 VW-1 Application Coaxial power cable with halogen free insulation and jacket. DC cable intended for automotive and telecom applications. To be used indoors and under dry conditions. 287 01–TFL 252 1 Rev C Downloaded from Arrow.com. TFL 252 1 RLCL Technical data Part no. Conductors x size TFL 252106/8 TFL 252110/8 TFL 252116/0 TFL 252116/8 TFL 252125/8 TFL 252135/8 TFL 252150/8 1 x 6+6mm² (10 AWG) 1 x 10+10mm² (8 AWG) 1 x 16+16mm² (6 AWG) 1 x 16+16mm² (6 AWG) 1 x 25+25 mm² (4AWG) 1 x 35+35 mm² (2AWG) 1 x 50+50 mm² (1AWG) Diameter, nom. (mm) Conductor Insulation Jacket 3,0 4,7 5,4 5,4 6,7 8,0 9,9 4,5 6,1 7,0 7,0 8,3 10 12 7,5 10,7 11,8 11,8 13,5 15,2 18,6 Weight/100m (kg) Resistance (ohm/km) 14 22 35 35 53 71 100 3,39 1,95 1,24 1,24 0,795 0,565 0,393 Ordering Information Part no. Conductors x size TFL 252106/8 TFL 252110/8 TFL 252116/0 TFL 252116/8 TFL 252125/8 TFL 252135/8 TFL 252150/8 1 x 6+6mm² (10 AWG) 1 x 10+10mm² (8 AWG) 1 x 16+16mm² (6 AWG) 1 x 16+16mm² (6 AWG) 1 x 25+25 mm² (4AWG) 1 x 35+35mm² (2 AWG) 1 x 50+50 mm² (1AWG) 287 01–TFL 252 1 Rev C www.ericsson.com Downloaded from Arrow.com. Length (m) Drum Total weight (kg) 1000 500 500 500 500 500 300 K6 K6 K6 K6 K8 K8 K8 165 122 187 187 290 380 325 Ericsson AB 2010 Phone: +46 10 719 00 00 2 (2)