SEL-787 Transformer Protection Relay SEL Advances the State of the Art in Transformer Protection • Synchrophasors detect system oscillations and potential instability. • Mirrored Bits® communications is ideal for teleprotection and remote control applications. • Flexible communications make control integration fast and easy. • Small form factor speeds new installations and retrofits of electromechanical relays. • Commissioning Assistant is the first transformer relaying software that recommends correction settings after identifying errors. Optimize the Life of Your Transformers by Monitoring Key Health Indicators Flexible Communications Single or Dual Copper or Fiber Ethernet Port Three or Four* Serial Ports Cumulative Through-Fault Current Recording Measurement and Logic Input Use Commissioning Assistant to Easily Generate Differential Compensation Settings *Optional Industry-Leading Quality, Reliability, and Customer Service —40°C +85°C Making Electric Power Safer, More Reliable, and More Economical ® Functional Overview SEL-787 Transformer Protection Relay Voltage Input 3 59 P Q Overvoltage • Phase • Neg. Seq. P 3 27 P Undervoltage • Phase P 50 QG 51 G Q BF 81 24 Volts/Hertz Frequency • Over • Under 49 Loss-of-Potential • Sequential Events Recorder • SEL ASCII, Ethernet*, Modbus TCP*, IEC 61850*, DNP3 LAN/WAN*, DNP3 Serial*, Modbus RTU, Telnet*, FTP*, and SNTP* • Synchrophasor Data and IEEE C37.118-Compliant Protocol • Front-Panel LED Programmable Targets 87 Temperature Alarm and Trip LOP • Event Reports 32 Overcurrent Time-Overcurrent Directional • Phase • Phase Power • Ground • Ground • Neg. Seq. • Neg. Seq. • Breaker Failure Internal or External RTD Inputs O U Current Differential • Two Inputs and Three Outputs Standard • I/O Expansion*—Additional Contact Inputs, Contact Outputs, Analog Inputs, Analog Outputs, and RTD Inputs • Single or Dual Ethernet Copper or Fiber-Optic Communications Port* 52 1 3 50N 51N Neutral Overcurrent Neutral Time-Overcurrent 50 P G Q BF P 51 G Q Overcurrent Time-Overcurrent • Phase • Phase • Ground • Ground • Neg. Seq. • Neg. Seq. • Breaker Failure 87G Restricted Earth Fault (REF) • Battery-Backed Clock, IRIG-B Time Synchronization • Instantaneous Metering • Programmable Pushbuttons and LED Indicators • Through-Fault Monitoring • Advanced SELOGIC® Control Equations • 32 Programmable Display Messages • MIRRORED BITS Communications • Transformer Thermal Monitoring *Optional Functions Ordering Options Feature Overview Power supply options include 24—48 Vdc or 110—250 Vdc/110—240 Vac. Optional Modbus TCP, Telnet, FTP, IEC 61850, and DNP3 LAN/WAN. Mirrored Bits communications. Single or dual copper or fiber Ethernet port. IRIG-B input. Fiber-optic serial port. Positions for optional expansion cards. Two-winding CT inputs. Shown with optional RTD inputs. Optional neutral CT input (REF). Optional voltage input. • CPU Board - Single or dual copper or fiber Ethernet port - EIA-232 or EIA-485 rear port - IRIG-B input • Optional Expansion Cards - 3 digital inputs/4 digital outputs/4—20 mA analog output - 4 digital inputs/4 digital outputs (electromechanical) - 4 digital inputs/4 digital outputs (fast, high-current interrupting) - 4 analog inputs/4 analog outputs - EIA-232 or EIA-485 serial communication - 8 digital inputs - 10 RTD inputs - Neutral ac current input - Neutral ac current input/three-phase ac voltage (300 Vac) input • Conformal Coating Pullman, Washington USA Tel: +1.509.332.1890 • Fax: +1.509.332.7990 • www.selinc.com • info@selinc.com © 2007–2019 by Schweitzer Engineering Laboratories, Inc. PF00167 • 20190404