CREATING AIR MOVEMENT FOR INNOVATION .................... This Fan! 14th edition Introduction Axial Fans Motors Radial Fans Pumps High Temperature Application Control Equipment Technical Information Wiring Diagrams 2 This Fan 14th edition Index_2019 Large Square Plate 24 Basket Grille 26 Compact Range 30 ESM Fans 32 34 iQ- and Q-Motors 34 40 Backward Curved 42 Forward Curved – Single Inlet 46 Forward Curved – Double Inlet 48 52 Evaporative Cooler 52 54 Oven Fans & Heaters 54 56 Controllers & Sensors 56 58 Velocity Pressure – Air (Pv) Chart Hooke‘s Law for Fans Humidity Classes 58 59 60 61 Wiring Connection Diagrams EC Wiring Diagrams 61 71 Introduction 22 Axial Fans Square & Round Plate Motors 20 Radial Fans Motorised Impeller 18 Pumps 4 5 6 9 10 14 Controls HiTemp This Fan Certification About ebm-papst EC Technology Fan Identification ebm-papst Part Numbers & Label Location Tech Info 2 Page Diagrams Page 3 This Fan ebm-papst, a certified company This is a short form catalogue directed at the replacement market, and therefore is intentionally brief. Local Product ebm-papst stocks a large variety of different fans and motors in Australia and New Zealand for the local market. This catalogue covers the products typically used in Australia and New Zealand. Imported Products There are overseas manufacturers‘ products imported into Australia and New Zealand using our fans and motors, which we may not stock locally. Usually a locally stocked fan or motor will satisfactorily replace the original. As we have products for a wide range of different power supplies, when replacing components of imported product it is very important to check operating voltage and frequency as well as air flow direction. Product Identification Identification labels are placed on all fans before leaving the factory; correct identification makes replacement an easy exercise – see page 15 to 17 for more identification information. Warranty All ebm-papst labelled products sold in AU & NZ carry 2 years warranty from date of purchase, subject to correct use and application. Specific warranty details are available on request. Availability To locate your nearest wholesaler contact ebm-papst on (03) 9360 6400 in Australia or (09) 525 0245 in New Zealand or check our website www.ebmpapst.com.au or www.ebmpapst.co.nz. 4 Disclaimer Whilst every care has been taken in compilation of this catalogue, ebm-papst A&NZ Pty Ltd takes no responsibility for any errors or inaccuracies. For more information please contact your ebm-papst representative. Quality ISO 9001 Environment ISO 14001 In this catalogue, we have identified all high efficiency EC products with green text and logo. EC fans can lower power consumption by up to 90%. 5 Introduction Sound Data The suction-side sound power levels L�(A) and sound pressure levels at 1m Lp(A) provided in this publication are measured as per ISO 13347. The acoustic values given are only valid under the measurement conditions and will vary depending on the installation situation. About ebm-papst The engineer's choice The engineers choice! ebm-papst provides a wide range of high quality and highly efficient air movement systems. Combined with excellent customer service and local engineering support, it is a brand you and your customer can rely on. Our offices in Melbourne, Sydney and Auckland consist of a team of qualified engineers, developers, logistics and other highly qualified professionals, accounting for more than 100 years of combined fan engineering experience. Specialising in aerodynamics, motor technology and controls allows us to offer the best air-movement solution for your application. 6 Introduction Above: AIRAH Awards Night 2018 – Winner 'Excellence in Diversity and Inclusion Award' Above: ebm-papst A&NZ Team gathering 2019 7 Experience ebm-papst A&NZ: Excellent Sales Team Our sales representatives are engineers with excellent product knowledge, who work in close collaboration with you to select the most suitable fan product. We aim to not just be a fan supplier, but be your development partner. Development and Engineering Our recently launched Centre of Excellence allows our project and design engineers to develop local fan products and accessories to provide an innovative solution to your air-movement requirement. We aim to maximise the performance of our products in your application and offer free testing on our local air performance test rig. 8 Technical Support Our sales team is supported by highly qualified local engineers. If you need support on site, we aim to be there within 24 hours. Logistics We work closely with your supply team to ensure adequate stock availability and delivery when you need it. EC Upgrades Together with our partners we can find an upgrade solution for your existing system.We upgrade your HVAC-R installation to boost performance, save energy or reduce maintenance cost. In most cases, there is no need to invest in new capital equipment to benefit from innovative fan technologies: Simply switch to Green Intelligence EC fans. EC Technology ebm-papst EC technology (EC = electronically commutated) is an environmentally sound and a more cost-effective alternative to AC technology. ebm-papst EC fans and motors give you high-performance, silent speed control and long life expectancy in a product which is the same size as the power hungry AC products it replaces. More information and case studies are available on ECupgrades.com.au. Power Consumption Input Power P [%] 100 75 50 AC EC 25 0 25 50 75 100 Air Flow qv [%] Low energy consumption: The bars show the power input of fans that are activated incrementally as needed. The air performance is reduced by 50% if 50% of the fans are shut off. The blue line shows the power input with continuous speed adjustment. If all EC fans are reduced to 50% of their maximum speed, the power is reduced by 87.5%, compared to 50% reduction when half of the AC fans are turned off. Lower noise: While shutting off half of the fans (one-half of the air flow) decreases the noise level by only about 3 dB. When reducing the speed of all fans to 50% of the maximum speed, the noise is reduced by 15dB(A). 9 Introduction Upgrade to EC Centrifugal or radial (D, E or F) Looks like a rotating drum ‘S’ Blades (B) HyBlade (C) Sickle shaped blades (5, 7 or 9 blades) HyBlade (3 or 5 blades, plastic) Backward curved cetrifugal (D or F) Forward curved centrifugal (E) Few blades Many Blades Radial ‘A’ Blades (A) Straight blades (typically 5 blades) Axial 3. What do the blades look like? Up to 1250mm Radial Up to 1600mm Axial 2. What is the diameter of the impeller? Axial (A, B or C) Looks like a propeller 1. What does the impeller look like? Fan Identification Helpful hints for fan identification D A E B F C 11 (B1 or B2) (C) Welded sheet steel HyBlade (composite plastic) (E, I or J) Aluminum (H) (A, B or C) Flat grille No mounting Radial Fans Motors (J, K or L) Scroll housing 2 inlets Pumps (I) Scroll housing 1 inlet Controls HiTemp (Commonly) forward curved (I, J, K or L) Housing Diagrams (Commonly) backward curved (D or E) No housing Tech Info (G) Basket grille Radial (F1 or F2) Wall plate square or round Axial 5. What is the mounting Style or Housing? (D, K or L) Plastic Radial ‘S’ Blade (bolted fastening) (A) Die-cast alloy Axial 4. What is the material of the blades? Axial Fans F2 A J D K Introduction G B1 E H B2 F1 L I C (B) EC Airflow ‘V’ (out over mounting brackets) Blow away from you? At 90° angle to the motor Radial Airflow ‘A’ Blow towards you? When looking at rotor (spinning part) does the air: Axial 7. Which way does the air flow? (A) AC 6. Is it an AC or EC Motor (EC has electronics built into the back of the motor)? What fan is that? Helpful hints for fan identification A B 13 Single-phase We can only offer the closest alternative We may be able to find the model depending on the brand 8 pole ~720rpm Diagrams Controls HiTemp 6 pole ~960rpm Tech Info 4 pole ~1440rpm Not applicable to EC motors 2 pole ~2800rpm Pumps Radial Fans 10. What is the fan speed? (Customers may not know this if the label has worn off) Local equipment Imported equipment 9. Is the equipment manufactured locally or overseas Other voltage may apply if from imported equipment If a capacitor is present Single-phase (230V), three-phase (400V) or DC 8. What is the power supply (Lead count is not an indication) Motors Axial Fans Introduction Evaporator: cool room, freezer room, display cabinet Condenser: rooftop, bottle cooler Air conditioning: air handling unit (AHU), fan coil unit, supply/return air fans Ventilation: exhaust, inline High temperature application: oven, heater Examples of typical applications: 11. What is the application? To better understand your needs, and to propose a suitable replacement, the more you know and can tell us about the application, the better we can help you. 0 A S 5 7 2 4 6 4 C T Indicates carton version 2,4,6 or 8 = Number of poles (speed) 1 or 3 = 1 or 3 core EC products, it is not representative of speed D= Three-phase motor E = Single-phase motor G = EC motor S = Shaded pole motor Q = Square motor Impeller diameter Fan and motor configuration 3 4 5 6 R = Bare fan and motor D = Forward curved (double inlet) with housing G = Forward curved (single inlet) with housing K = Centrifugal assembly 0 4 Radial/Centrifugal 3 2 1 3 E A = Bare fan and motor S = With grille W = With wall plate M = Motor 4 Axial fans 2 1 S Ebm-papst Axial and Radial/Centrifugal Part number system 15 Diagrams Tech Info AC axial – label Controls HiTemp Pumps Radial Fans AC axial – print Part Number / Label Location Motors Axial Fans Axial wall plate Introduction AC double inlet Compact fan EC axial Part Number/Label Locations EC axial wallplate – motor EC axial wallplate – plate 17 Diagrams Tech Info EC double inlet Controls HiTemp Pumps Radial Fans Radial cube design Motors Axial Fans Q-motor Introduction EC spider mount Axial Fans 19 Diagrams Tech Info Controls HiTemp Pumps Radial Fans Motors Axial Fans Introduction Axial fans are typically used for high air volume, low pressure applications. With this fan type it is recommended to use a housing with full inlet nozzle as it provides the best aerodynamic performance. Not using a housing with full inlet nozzle can result in performance losses of 10-15%, a reduction in efficiency and an increase in noise. As the name suggests, Axial fans move air in an axial direction. Looking at the rotor, they can either push air away from you (V-flow) or towards you (A-flow). Axial Fans Motorised Impeller HyBlade A S JB = Junction Box Part No. A2E200AK3801 A2E200AI3801 A4S200AH0401 A4S200AI0401 A2E250AL0601 A2E250AE6502 A4S250AH0201 A2E300AC4702 A4E300AS7201-CT0 A4E300AS7202-CT0 A4E350AA1032-CT0 A4E350AN0201 A4D400AP1620 A6E400AP1012-CT0 A4D450AO1401 A4E450AO0909 A6E450AJ0811-CT0 A6E450AQ0511-CT0 A4D500AJ0301 A6E500AJ0305-CT0 Dimensions Style S S S S S A S A HyBlade HyBlade A HyBlade S S HyBlade HyBlade S S HyBlade HyBlade A 198 197 197 197 251 250 251 300 300 300 353 352 392 392 446 446 446 446 497 497 B 61 57 54 55 52 66 52 50 71 58 91 97 94 86 103 103 100 96 108 108 C 48 39 39 39 34 39 34 20 58 51 70 87 68 88 96 96 93 92 105 105 D 64 62 62 62 72 83 72 98 73 80 102 105 117 104 148 148 122 117 124 124 E 450 450 450 450 450 450 450 450 450 450 350 600 2500 1250 JB 600 1500 1500 JB 1800 21 Style S S S S S A S A HyBlade HyBlade A HyBlade S S HyBlade HyBlade S S HyBlade HyBlade FA = Free air at 0Pa ML = Maximum load Diagrams Tech Info Part No. A2E200AK3801 A2E200AI3801 A4S200AH0401 A4S200AI0401 A2E250AL0601 A2E250AE6502 A4S250AH0201 A2E300AC4702 A4E300AS7201-CT0 A4E300AS7202-CT0 A4E350AA1032-CT0 A4E350AN0201 A4D400AP1620 A6E400AP1012-CT0 A4D450AO1401 A4E450AO0909 A6E450AJ0811-CT0 A6E450AQ0511-CT0 A4D500AJ0301 A6E500AJ0305-CT0 Airflow Direction Hz 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 Frequency Pumps V 230 230 230 230 230 230 230 230 230 230 230 230 400 Δ/400 Y 230 400 Δ/400 Y 230 230 230 400 Δ/400 Y 230 Nominal Voltage Controls HiTemp V A V A V A V A V A V V V V V V V V V V Airflow at 0Pa Radial Fans m3/hr 930 890 470 470 1820 1610 1000 2440 1800 1800 3100 3300 4180/3780 3290 7070/6030 7070 4445 4475 9030/7670 6100 Nominal Data at RPM 2670 2600 1370 1370 2450 2550 1390 2650 1320 1320 1400 1340 1440/1300 940 1360/1110 1310 850 910 1340/1060 915 Speed Motors FA FA FA FA FA FA FA FA ML ML FA ML FA n/a ML ML ML FA ML ML Power Input Axial Fans W 60 64 30 30 115 115 69 140 72 72 130 165 170/115 120 480/340 490 160 155 710/480 270 Current Draw A 0.3 0.3 0.21 0.21 0.51 0.51 0.53 0.62 0.32 0.32 0.55 0.73 0.53/0.21 0.56 0.98/0.58 2.36 0.7 0.7 1.4/0.8 1.18 Sound Pressure Level at 1m °C 65 65 75 75 65 55 50 55 50 50 45 65 55/85 55 65 65 55 70 60 65 Max. Perm. Amb. Temperature Introduction dB(A) 57 65 42 42 69 72 54 75 53 53 n/a 56 67/65 59 62 62 n/a 62 64/58 56 Capacitor μF/V 1.5/450 1.5/450 – – 3.0/400 4.0/400 – 5.0/400 2.0/400 2.0/4.00 4.0/400 4.0/400 – 3.0/450 – 10.0/400 4.0/400 4.0/450 – 8.0/400 Approximate Weight kg 1.3 1.3 1.2 1.2 2 2.2 1.7 2.5 1.8 1.8 3.1 3.5 4.3 n/a 7.2 7.3 3.7 4 7.7 7.5 Wiring Diagram A1 A1 B B A1 A1 B A1 A1 A1 A1 A1 F1a / F2a A1 F1b / F2b A2a A1 A1 F1b / F2b A2a AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC Motor Type Axial Fans Square and Round Plate Square Wall Plate Round Wall Plate A 200 200 200 257 257 257 326 326 327 W2E200DH3801 W2E200DI3801 W4S200DI0401 W2E250DE6502 W4S250DI0201 W2E300DC4702 W4E300DS72CT-002 200 200 200 257 256 326 327 Square Plate Dimensions Part No. W2E200CH3801 W2E200CI3801 W4S200CI0401 W2E250CL0601 W2E250CE6502 W4S250CI0201 W2E300CC4702 W4E300CS72CT-001 W4E300CS72CT-002 Round Plate Dimensions 64 62 62 83 73 98 113 B 80 80 80 87 85 87 80 113 113 312 312 312 370 370 430 430 C 280 280 280 320 320 320 397 397 397 260 260 260 320 320 380 380 D 250 250 250 295 295 295 380 380 380 23 Diagrams FA = Free air ML = Maximum load Part No. W2E200DH3801 W2E200DI3801 W4S200DI0401 Part No. W2E200CH3801 W2E200CI3801 W4S200CI0401 W2E250CL0601 W2E250CE6502 W4S250CI0201 W2E300CC4702 W4E300CS72CT-001 W4E300CS72CT-002 Tech Info V A A V A A A V A Airflow Direction Controls HiTemp W4E300DS72CT-002 W2E250DE6502 W4S250DI0201 W2E300DC4702 Square Plate Round Plate Nominal Voltage Pumps V 230 230 230 230 230 230 230 230 230 Frequency m3/hr 930 890 470 1820 1610 1000 2440 1800 1800 Airflow at 0Pa Radial Fans Hz 50 50 50 50 50 50 50 50 50 Nominal Data at Motors FA FA FA FA FA FA FA ML ML Speed RPM 2600 2600 1370 2450 2550 1390 2650 1320 1320 Power Input Axial Fans W 64 64 30 115 115 69 140 72 72 Current Draw A 0.3 0.3 0.21 0.51 0.51 0.53 0.62 0.32 0.32 Sound Pressure Level at 1m dB(A) 65 65 42 69 72 54 75 53 53 Max. Perm. Amb. Temperature Introduction °C 65 65 75 65 55 50 55 50 50 Capacitor μF/V 1.5/450 1.5/450 – 3.0/400 4.0/400 – 5.0/400 2.0/400 2.0/4.00 Approximate Weight kg 2.3 2.4 1.2 1.9 4.1 3.1 4.7 3.7 4 Wiring Diagram A1 A1 B A1 A1 B A1 A1 A1 AC AC AC AC AC AC AC AC AC Motor Type <"V" "A" > Axial Fans Large Square Plate D C nice axiBlade pic plus on cover Part No. W4D500GJ0311 W3G500GN3307 W3G500GM5694 W4D630GD0101 W3G630GU2301 W6D800KG1301 W8D800KG0101 W3G800KS3903 W3G800KU2103 W3G910KS3503 W3G910KU2503 Dimensions A 542 542 542 696 696 923 923 923 923 1022 1022 B 176 170 170 227 250 336 336 334 334 338 338 C 600 600 656 805 805 970 970 970 970 1070 1070 D 560 560 615 750 750 910 910 910 910 1010 1010 25 Diagrams FA = Free air ML = Maximum load *Data shown is for 50Hz Δ/Y Part No. W4D500GJ0311 W3G500GN3307 W3G500GM5694 W4D630GD0101 W3G630GU2301 W6D800KG1301* W8D800KG0101* W3G800KS3903 W3G800KU2103 W3G910KS3503 W3G910KU2503 Tech Info Style HyBlade HyBlade HyBlade HyBlade HyBlade AxiBlade AxiBlade AxiBlade AxiBlade AxiBlade AxiBlade Airflow Direction Hz 50 50/60 50/60 50 50/60 50/50 50/60 50/60 50/60 50/60 50/60 Frequency Pumps V 400 Δ /400 Y 380-480 200-277 400 Δ /400 Y 380-480 400 Δ /400 Y 400 Δ /400 Y 380-480 380-480 380-480 380-480 Nominal Voltage Controls HiTemp V V V V V V V V V V V Airflow at 0Pa Radial Fans ML ML ML ML ML ML ML ML ML ML ML Nominal Data at Motors m3/hr 9030/7670 10390 9245 19890 /16680 21190 23030/19070 17890/15590 25740 29510 29145 33630 Speed W 710/480 980 750 2630/1750 3200 1430/840 730/460 1950 2900 1770 2250 Power Input Axial Fans RPM 1340/1060 1600 1420 1320/1050 1510 870/650 680/540 940 1080 850 980 Current Draw dB(A) 64 / 58 68 66 73/67 78 74/64 65/58 79 85 79 75 Sound Pressure Level at 1m Introduction A 1.4/ 0.8 1.6 3.4 4.78/2.95 5 2.8/1.6 2.0/0.96 3.1 4.4 2.8 3.9 Max. Perm. Amb. Temperature °C 60 60 60 60 65 60/60 60/60 60 60 60 60 Approximate Weight kg 14 15.8 14.8 38.9 40 44 44 43 47.5 45 48 Wiring Diagram F1b / F2b L2 L7 F1b / F2b L5 F1b / F2b F1b / F2b RP6 RP6 RP6 RP6 AC EC EC AC EC AC AC EC EC EC EC Motor Type C D A B V A Axial Fans Basket Grille Part No. S2D170BA0406 S4E300AR26CT-002 S4E300AS72CT-001 S4E300AS72A2-CT0 S1G300FO0111-CT0 S3G300AK1358-CT0 S3G300AK1360-CT0 S4E350AN02CT-048 S4E350AN02CT-060 S3G350AN01CT-002 S3G350AP0160-CT0 Dimensions A 170 300 300 300 300 300 300 352 352 352 352 B 220 360 360 360 360 360 360 422 442 442 422 C 4 100 115 99.5 68.5 116 126 122 111 116 126 D 63 49 23 49.4 33.8 28 28 55 65 56 58 27 Diagrams FA = Free air ML = Maximum load Part No. S2D170BA0406 S4E300AR26CT-002 S4E300AS72CT-001 S4E300AS72A2-CT0 S1G300FO0111-CT0 S3G300AK1358-CT0 S3G300AK1360-CT0 S4E350AN02CT-048 S4E350AN02CT-060 S3G350AN01CT-002 S3G350AP0160-CT0 Tech Info Style A S HyBlade HyBlade HyBlade HyBlade S HyBlade HyBlade S S Airflow Direction V 400 Y 230 230 230 200-240 200-240 200-240 230 230 200-240 200-240 Nominal Voltage Controls HiTemp V V V A V V V V V V V Frequency Pumps Hz 50 50 50 50/60 50/60 50/60 50/60 50 50 50/60 50/60 Airflow at 0Pa FA FA ML ML ML ML ML ML ML ML ML Nominal Data at Radial Fans m3/hr 470 1935 1800 1800 1550 1975 2265 3305 3305 3420 3925 Speed Motors W 45 70 70 72 62 60 85 165 165 160 165 Power Input Axial Fans RPM 2750 1380 1330 1320 1250 (high speed) 1360 1500 1340 1340 1450 1475 Current Draw A 0.13 0.32 0.31 0.32 0.55 0.53 0.8 0.73 0.73 1.3 1.35 Sound Pressure Level at 1m dB(A) 64 59 53 53 56 54 58 56 56 57 57 Max. Perm. Amb. Temperature μF/V – 2.0/400 2.0/400 2.0/4.00 – – – 4.0/400 4.0/400 – – Capacitor Introduction °C 75 55 40 50 40 60 60 40 40 40 60 Approximate Weight kg 1.4 3.1 3 2.9 1.6 2.5 2.7 5.1 5.1 3.7 4.3 Wiring Diagram C2 A1 A1 A1 ESM H3 H4 A1 A1 H3 H4 AC AC AC AC EC EC EC AC AC EC EC Motor Type C D A B V A Axial Fans Basket Grille Part No. S4E400AP0244-CT0 S4E450AU0337-CT0 S4E450BU0335-CT0 S4D500AM0301-CT0 S4E500AM0301-CT0 S3G500AM56CT-001 S6E560AN0101 S6D630AN0101 S6E630AN0101 S3G630AU2301 S6E710AR0301 Dimensions A 392 445 445 497 497 497 552 626 626 627 703 B 470 522 522 565 565 565 700 750 750 750 853 C 117 116 36 126 126 108 102 124 124 178 155 D 67 57 107 84 84 64 108 86 86 76 70 29 Diagrams FA = Free air ML = Maximum load Part No. S4E400AP0244-CT0 S4E450AU0337-CT0 S4E450BU0335-CT0 S4D500AM0301-CT0 S4E500AM0301-CT0 S3G500AM56CT-001 S6E560AN0101 S6D630AN0101 S6E630AN0101 S3G630AU2301 S6E710AR0301 Tech Info Style S S S HyBlade HyBlade HyBlade HyBlade HyBlade HyBlade HyBlade HyBlade Airflow Direction V 230 230 230 400 Δ /400 Y 230 200-277 230 400 Δ /400 Y 230 380-480 230 Nominal Voltage Controls HiTemp V V V V V V V V V V V Frequency Pumps Hz 50 50 50 50 50 50/60 50 50 50 50/60 50 Airflow at 0Pa Radial Fans m3/hr 4235 5770 5770 9195/8255 8905 9245 8105 11270/9620 11020 21190 11700 Nominal Data at RPM 1430 1300 1300 1390/1180 1300 1420 920 890/690 860 1510 900 Speed Motors FA ML ML ML ML ML ML ML ML ML ML Power Input Axial Fans W 160 350 350 720/550 680 750 390 600/400 600 3200 630 Current Draw A 0.73 1.55 1.55 1.41/0.9 3 3.4 1.78 1.2/0.68 2.62 5 2.79 Sound Pressure Level at 1m °C 60 55 55 65 65 60 75 65 55 65 65 Max. Perm. Amb. Temperature Introduction dB(A) 67 70 65/62 65 66 61 60/55 61 78 70 Capacitor μF/V 6.0/400 8.0/400 8.0/450 12.0/450 10.0/400 14.0/400 14.0/450 Approximate Weight kg 6.1 7 6.3 13 13 10.5 14.5 14 14 32.4 19.3 Wiring Diagram A1 A1 A1 F1b/F2b A2b L1 A2b F1b/F2b A2b L5 A2b AC AC AC AC AC EC AC AC AC EC AC Motor Type Axial Fans Compact Range A C D B Part No. 8314 8556N 3956 4412FM-CT0 9956-CT1 4314-CT0 4184NX-CT1 4650Z-CT1 4650N-CT1 4656Z-CT1 4656N-CT1 ACi4420HHR-CT1 5958 7214N 6224N W2S130AA0363 W2S130BM0301 W1G130AA2511 W2E142BB0101 W2E200HK3801 Dimensions Case Style B B B B B B B B B B B B B A C A A A A D A 80 80 92 119 119 119 119 119 119 119 119 119 127 150d 172d 150d 150d 150d 153d 225 B 32 38 25 25 25 32 38 38 38 38 38 38 38 55 51 55 55 58 38 80 C 72 72 83 105 105 105 105 105 105 105 105 105 113 162d 162d 162d 162d 162 162d 170 D 5 3 4 4 4 5 6 10 6 10 6 6 7 6 – 6 6 10 11 7 31 Airflow Direction V V V V V V A V A V A V V V V V A V V V V 24 230 230 12 230 24 24 230 230 230 230 195-265 230 24 24 230 230 230 230 230 Nominal Voltage PIN connectors require seperate lead. LZ126 Lead + Plug 1000mm Part No. 8314 8556N 3956 4412FM-CT0 9956-CT1 4314-CT0 4184NX-CT1 4650Z-CT1 4650N-CT1 4656Z-CT1 4656N-CT1 ACi4420HHR-CT1 5958 7214N 6224N W2S130AA0363 W2S130BM0301 W1G130AA2511 W2E142BB0101 W2E200HK3801 Frequency Pumps Hz – 50 50 – 50 – – 50 50 50 50 50/60 50 – – 50 50 50/60 50 50 Airflow at 0Pa Radial Fans m3/hr 54 50 59 140 117 170 180 160 160 160 160 180 180 360 410 340 385 370 320 880 Motors Speed RPM 3300 2800 2650 2400 2450 2800 3200 2650 2650 2650 2650 3350 2750 3050 3400 2800 2700 3200 2800 2550 Power Input Axial Fans W 2.7 12 11 3.2 14 5 4.9 19 19 19 19 4.4 18 12 18 45 47 23 27 64 Sound Pressure Level at 1m dB(A) 36 31 35 38 37 45 49 40 46 40 47 42 44 53 55 49 60 55 51 58 Max. Perm. Amb. Temperature Introduction °C 75 90 80 75 70 75 70 50 55 75 85 75 60 72 72 50 50 70 55 60 Approximate Weight kg 0.17 0.49 0.28 0.175 0.8 0.22 0.39 0.54 0.55 0.54 0.55 0.25 0.57 0.725 0.82 1.13 1.1 0.8 0.8 2.1 Lead 310 310 PIN 310 PIN 310 PIN PIN PIN PIN PIN PIN PIN 365 PIN 1500 330 1500 PIN Terminal DC AC AC DC AC DC DC AC AC AC AC EC AC DC DC AC AC EC AC AC Motor Type Axial Fans ESM Fans Truncated Standard Part No. W1G172EC9101-CT0 W1G200EC9110-CT0 W1G200EC9145-CT0 W1G230EB9122-CT2 Dimensions Type standard truncated standard truncated A 172 200 200 250 B 208 236 236 266 C 222 250 250 280 D 78.5 78.5 78.5 78.5 E 35 40 40 50 33 Airflow Direction V V V V Nominal Voltage V 230 230 230 230 Frequency Hz 50/60 50/60 50/60 50/60 Airflow at 0Pa m3/hr 525 750 750 1060 Speed RPM 2500 2100 2100 1600 Power Input W 22 31 31 32 Current Draw A 0.18 0.24 0.24 0.3 Sound Pressure Level at 1m dB(A) 54 54 54 n/a Max. Perm. Amb. Temperature °C 50 50 50 50 Speed Step high–low high–low high–low high–low Approximate Weight kg 0.8 1 1 1 ESM ESM ESM ESM Wiring Diagram EC EC EC EC Diagrams Tech Info Controls HiTemp Pumps Radial Fans Motors Axial Fans Introduction ebm-papst energy-saving motors (ESM fans) have 2 programmable speeds with a motor and electronics system that is robust, maintenance-free and durable. ESM fans are designed for refrigeration applications, especially for display cases and bottle cooler evaporators. Part No. W1G172EC9101-CT0 W1G200EC9110-CT0 W1G200EC9145-CT0 W1G230EB9122-CT2 Motor Type Motors iQ- and Q-Motors The iQ3620 can replace all 16W and 18W Q-motors as well as 23W, 25W and 34W Q-motors up to a certain impeller size. For details, refer to page 38. The iQ3612 and iQC3612 can replace all 5W, 7W and 10W Q-motors. One iQ-motor part number can replace several Q-motor part numbers. The iQ-motor has been designed as a high efficiency replacement for the existing Q-motors currently used in many different applications. With up to 93% power savings there is an iQ-motor suitable for almost all replacement applications. 35 Diagrams Tech Info Blade pitch 22 degrees 170 2 230 2.6 360 3.4 520 6 710 11.3 1380 24.3 Impeller diameter 154 172 200 230 254 300 *Free airflow with wall ring m3/h Controls HiTemp W Airflow @ 0Pa* mm iQ-Motor Power Consumption Technical Data Typical iQ-motor combined with different axial impellers (speed 1,300 RPM) Q-Motor Power Consumption Pumps 29 29 31 36 58 62 W SAVE Radial Fans 93% 91% 89% 83% 81% 61% % Airflow @ 0Pa* W iQ-Motor Power Consumption Motors Blade pitch 28 degrees 190 2.8 270 2.9 410 5.3 710 13.1 980 23.1 m3/h Q-Motor Power Consumption 29 29 31 36 58 W SAVE 90% 90% 83% 64% 60% % Airflow @ 0Pa* W iQ-Motor Power Consumption Introduction Blade pitch 34 degrees 220 3.3 310 3.8 470 7.3 750 16.9 1010 28.4 m3/h Q-Motor Power Consumption 29 29 31 36 62 W 89% 87% 76% 53% 54% % SAVE Motors iQ- and Q-Motors iQC motor iQ motor Q motor See page 39 for impeller sizes Part No. M4Q045BD0138-CT0 M4Q045CA0138-CT0 M4Q045CA0172A01-CT0 M4Q045CA0338A01-CT0 M4Q045CA0375B01-CT0 iQ3612-00-CT0 iQC3612-00-CT0 M4Q045CF0138-CT0 M4Q045CF0175B01-CT0 M4Q045DA0538-CT0 M4Q045DA0575B01-CT0 M4Q045EA0138-CT0 iQ3620-01-CT0 M4Q045EF0138-CT0 M4Q045EF0175B01-CT0 Dimensions A 42 42 42 42 42 43.5 43.5 42 42 54 54 59 43.5 79 79 B 76 82 82 82 82 82 85 87 87 93 93 103 82 125 125 C+D 27 25 25 25 25 27 30.5 25 25 25 25 26 27 43 43 37 Direction of Rotation CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW W 5 7 7 10 10 ≤15 ≤15 16 16 23 23 25 ≤25 34 34 Power Output Diagrams Tech Info Pumps V 230 230 230 230 230 220-240 220-240 230 230 230 230 230 220-240 230 230 Voltage Controls HiTemp KL = Ball bearing GK = Sleeve bearing *Also available with Lyall and AMP plug connector on request Part No. M4Q045BD0138-CT0 M4Q045CA0138-CT0 M4Q045CA0172A01-CT0 M4Q045CA0338A01-CT0 M4Q045CA0375B01-CT0 iQ3612-00-CT0* iQC3612-00-CT0* M4Q045CF0138-CT0 M4Q045CF0175B01-CT0 M4Q045DA0538-CT0 M4Q045DA0575B01-CT0 M4Q045EA0138-CT0 iQ3620-01-CT0 M4Q045EF0138-CT0 M4Q045EF0175B01-CT0 Frequency Motors RPM 1300 1300 1300 1300 1300 1300 1300/1500 1300 1300 1300 1300 1300 1300 1300 1300 Speed Radial Fans Hz 50 50 50 50 50 50/60 50/60 50 50 50 50 50 50/60 50 50 Power Input W 29 31 31 36 36 23 20/22 60 60 86 86 90 32 110 110 Current A 0.19 0.2 0.2 0.25 0.25 ≤0.2 0.18/0.19 0.42 0.42 0.62 0.62 0.62 ≤0.22 0.75 0.75 Bearing GK GK GK GK GK KL KK GK GK KL KL KL KL KL GK Max. Perm. Amb. Temperature Introduction °C 40 40 40 40 40 50 50 40 40 40 40 40 50 40 40 Approximate Weight kg 0.9 1.1 1.1 1.2 1.2 0.6 0.5 1.3 1.3 1.6 1.6 2 0.8 2.2 2.2 Lead Length mm 450 450 380 450 1500 1500 2000 450 1500 450 1500 450 1500 450 1500 AC AC AC AC AC EC EC AC AC AC AC AC EC AC AC Motor Type Power Output 5 7 7 10 10 ≤15 ≤15 16 16 23 23 25 ≤25 34 34 Part No. M4Q045BD0138-CT0 M4Q045CA0138-CT0 M4Q045CA0172A01-CT0 M4Q045CA0338A01-CT0 M4Q045CA0375B01-CT0 iQ3612-00-CT0 iQC3612-00-CT0 M4Q045CF0138-CT0 M4Q045CF0175B01-CT0 M4Q045DA0538-CT0 M4Q045DA0575B01-CT0 M4Q045EA0138-CT0 iQ3620-01-CT0 M4Q045EF0138-CT0 M4Q045EF0175B01-CT0 Recommended Impellers Motors iQ- and Q-Motors X X X X X X X X 22° X 28° X 22° X 34° X 172mm 154mm X X 28° X X X 34° X X X 22° X X X 200mm X X X X 28° X X X X 34° X X X X X X 22° 230mm X X X X 28° X X X X 34° X X X X X X 28° X X X X X X 22° 254mm X 34° X X X X X X 22° 300mm X X X X X 28° X X 34° 39 Diagrams Part No. ‘V’ Flow 73801-2-3634 73802-2-3634 73803-2-3634 73804-2-3634 73805-2-3634 73806-2-3634 73807-2-3634 73808-2-3634 73809-2-3634 73810-2-3634 73811-2-3634 73812-2-3634 73813-2-3634 73814-2-3634 73815-2-3634 73816-2-3634 73817-2-3634 73818-2-3634 Controls HiTemp Part No. ‘A’ Flow 73761-2-3634 73762-2-3634 73763-2-3634 73764-2-3634 73765-2-3634 73766-2-3634 73767-2-3634 73768-2-3634 73769-2-3634 73770-2-3634 73771-2-3634 73772-2-3634 73773-2-3634 73774-2-3634 73775-2-3634 73776-2-3634 73777-2-3634 73778-2-3634 Tech Info Impeller Part Number Pumps Radial Fans Size & Blade Angle 154mm 22° ± 1°30’ 154mm 28° ± 1°30’ 154mm 34° ± 1°30’ 172mm 22° ± 1°30’ 172mm 28° ± 1°30’ 172mm 34° ± 1°30’ 200mm 22° ± 1°30’ 200mm 28° ± 1°30’ 200mm 34° ± 1°30’ 230mm 22° ± 1°30’ 230mm 28° ± 1°30’ 230mm 34° ± 1°30’ 254mm 22° ± 1°30’ 254mm 28° ± 1°30’ 254mm 34° ± 1°30’ 300mm 22° ± 1°30’ 300mm 28° ± 1°30’ 300mm 34° ± 1°30’ Motors Introduction Radial Fans 41 Radial Fans In contrast to backward curved fans, forward curved fans must have a scroll housing for optimum air flow. The housing can either have single inlet, meaning air intake only from one side, or double inlet, with air intake from 2 sides. Due to the requirement of a housing and air direction, forward curved fans are often also called forward curved blowers. Backward curved fans have a free-running impeller and do not need a scroll housing. Backward curved fans are typically used for applications with medium air volume and medium to high back pressure. It is always recommended to use backward curved fans with inlet rings. The air intake of a radial fan runs in parallel with the shaft. The air flow is then diverted by 90° in the impeller and discharged in a centrifugal direction. A Radial Fans Backward Curved C B A Part No. R2S133AE1705-CT0 R1G175AB6359-CT0 R2E180CB2809-CT0 R2E190RA2651-CT0 R3G190RB0101-CT0 R3G190RD4503 K3G190RD4509 R2E220RA3801-CT0 R3G220RC0503-CT0 K3G220RD5303 R2E225RA9209-CT0 R3G225RE0703 K3G225RE0703 R2E250RA5001 R4E250RA0105 R2E280AE5205 R4E280AD0805 R3G280RR03H1 Dimensions Type A A A A A A B A A B A A B A A A A A A 133 175 180 190 190 190 226 220 220 270 225 225 270 250 250 281 281 294 B 93 131 132 132 133 133 133 161 161 161 154 154 154 173 173 191 191 188 C 91 69 55 69 69 91 102 71 71 111 99 101 131 99 93 125 125 190 D 61 62 48 63 63 63 63 63.7 64 64 88 88 88 85 85 82 112 127 43 FA = Free air ML = Maximum load Part No. R2S133AE1705-CT0 R1G175AB6359-CT0 R2E180CB2809-CT0 R2E190RA2651-CT0 R3G190RB0101-CT0 R3G190RD4503 K3G190RD4509 R2E220RA3801-CT0 R3G220RC0503-CT0 K3G220RD5303 R2E225RA9209-CT0 R3G225RE0703 K3G225RE0703 R2E250RA5001 R4E250RA0105 R2E280AE5205 R4E280AD0805 R3G280RR03H1 Direction of Rotation CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW Nominal Voltage V 230 24 230 240 200-240 200-240 200-240 230 200-240 200-240 230 200-240 200-240 230 230 230 230 200-277 Frequency Hz 50 – 50 50 50/60 50/60 50/60 50/60 50/60 50/60 50 50/60 50/60 50 50 50 50 50/60 Airflow at 0Pa m3/hr 280 555 440 540 640 975 975 885 1015 1290 1195 1300 1300 1420 775 2110 1425 3415 Nominal Data at Radial Fans FA FA FA ML ML ML ML ML ML ML ML ML ML ML ML FA FA ML Speed RPM 2780 3100 2550 2400 2710 4120 4120 2100 2580 3230 2500 2860 2860 2500 1350 2700 1420 2700 Power Input W 36 34 60 50 57 169 169 88 85 168 155 170 170 210 47 225 78 500 Current Draw A 0.25 1.6 0.28 0.25 0.43 1.35 1.35 0.39 0.7 1.4 0.68 1.4 1.4 0.93 0.22 1 0.35 2.2 Sound Pressure Level at 1m dB(A) 55 n/a n/a 54 60 66 63 52 n/a 66 63 60 60 58 43 n/a n/a 66 Max. Perm. Amb. Temperature °C 40 60 40 55 60 60 60 50 60 45 70 60 60 70 55 40 40 60 Capacitor μF/V – – 1.5/450 1.5/450 – – – 2.0/450 – – 3.5/450 – – 5.0/400 1.5/400 7.0/400 2.5/450 – Approximate Weight kg 0.9 0.85 1.4 1.2 1 1.38 2 1.3 1.13 2.1 2.3 1.75 2.5 2.9 1.9 3.5 3.18 5 Wiring Diagram B n/a A1 A1 H3 H4 H4 A1 H4 H4 A1 H4 H4 A1 A1 A1 A1 P5 AC EC AC AC EC EC EC AC EC EC AC EC EC AC AC AC AC EC Motor Type C C B A B A Radial Fans Backward Curved D Spider mount (K) Cube design (C) Part No. K3G250PR04H2 K3G250PR17I9 K3G280PR04I2 K3G310AZ8802 K3G355PH4932 K3G400PI9202 K3G450PA23B1 K3G450PA3103 K3G500PA2371 K3G500PB2403 K3G500PB3331 K3G560RB3175 K3G560PC0431 K3G630RB3271 K3G630PV0401 K3G710PV0501 K3G800PV1301 K3G900AR1001 Dimensions Type K K K K K K K K K K K K K K C C C C A 400 400 400 500 500 500 630 630 630 630 630 800 800 800 760 960 960 1180 B 350 350 350 450 450 450 580 580 580 580 580 750 750 750 666 880 880 950 C 235 251 259 328 398 446 477 440 508 471 587 415 658 463 664 749 858 748 D 298 270 294 360 405 455 530 530 585 585 585 570 655 660 716 806 909 n/a 45 FA = Free air ML = Maximum load Part No. K3G250PR04H2 K3G250PR17I9 K3G280PR04I2 K3G310AZ8802 K3G355PH4932 K3G400PI9202 K3G450PA23B1 K3G450PA3103 K3G500PA2371 K3G500PB2403 K3G500PB3331 K3G560RB3175 K3G560PB3103 K3G560PC0431 K3G630RB3271 K3G630PV0401 K3G710PV0501 K3G800PV1301 K3G900AR1001 Direction of Rotation CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW Nominal Voltage V 200-277 200-277 200-277 380-480 380-480 380-480 380-480 380-480 380-480 380-480 380-480 380-480 380-480 380-480 380-480 380-480 380-480 380-480 380-480 Frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Airflow at 0Pa m3/hr 2990 3435 4000 6230 7230 10020 12265 14000 15200 15935 18160 14335 19300 21265 16845 25220 30565 37840 39435 Nominal Data at RPM 3080 3450 3000 4100 2870 2450 2140 2480 1910 2000 2250 1650 1700 1760 1300 1750 1430 1215 860 Speed Radial Fans ML ML ML ML ML ML ML ML ML ML ML ML ML ML ML ML ML ML ML Power Input W 500 750 750 3240 1900 2500 2900 4500 3450 4200 5700 2900 4400 5000 2800 7060 7050 7950 7520 Current Draw A 2.3 3.3 3.3 4.9 3.0 3.8 4.5 6.8 5.3 6.4 9.0 4.43 6.6 7.7 4.2 10.8 10.7 12.1 11.5 Sound Pressure Level at 1m dB(A) 66 73 69 84 73 74 74 78 76 79 80 69 75 77 70 78 76 76 73 Max. Perm. Amb. Temperature °C 40 40 45 40 55 40 60 40 40 45 40 55 40 40 55 40 40 40 40 Conduit and Cable Glands – – – CFK001 CFK001 CFK001 CFK001 – CFK001 – CFK002 CFK001 – CFK002 CFK001 CFK002 CFK002 CFK002 CFK002 Anti-Vibration Mount No No No No No No No No No No No No No No No Yes Yes Yes Yes Approximate Weight kg 8.8 9.5 9.1 25 25 26 37 33.2 38.7 43.3 45.5 42.6 53.3 68 55 97.3 128.7 148.3 222 Wiring Diagram P5 (RP3) P5 (RP3) P5 (RP3) M3 (RP1) M3 (RP1) M3 (RP1) M5 (RP2) RP6 M5 (RP2) RP6 M3 (RP1) M5 (RP2) RP6 M3 (RP1) M5 (RP2) M3 (RP1) M3 (RP1) M3 (RP1) M3 (RP1) EC EC EC EC EC EC EC EC EC EC EC EC EC EC EC EC EC EC EC Motor Type Radial Fans Forward Curved - Single Inlet Part No. G2E120CR2603 G2E140AI2801 G2E160AY4701 Dimensions A 110 130 130 C 98 120 120 E 67.5 92 92 F 77 94 94 I 99 100 100 K 171 227 227 M 180 248 248 47 FA = Free air ML = Maximum load Part No. G2E120CR2603 G2E140AI2801 G2E160AY4701 Direction of Rotation CW CW CW Nominal Voltage V 240 230 230 Frequency Hz 50 50 50 Airflow at 0Pa FA FA FA Nominal Data at Radial Fans m3/hr 290 500 590 Speed RPM 2200 2400 2100 Power Input W 80 160 240 Current Draw A 0.34 0.7 1.05 Max. Perm. Amb. Temperature °C 60 70 50 Capacitor μF/V 2.0/450 4.0/400 6.0/400 Approximate Weight kg 1.9 3.5 4 Wiring Diagram A1 A1 A1 AC AC AC Motor Type C A Radial Fans Forward Curved - Double Inlet D B Case Style B B C B D A A Type A and D require plug and lead option D2E133DM4701-CT0 D2E133AM8398-CT0 D2E146AP4722-CT0 D4E146AA0702-CT0 D3G146LV1330-CT2 D2E146HS9704-CT2 D2E146HT6701-CT2 Part No. Dimensions – – 270 – 272 173 173 A – – 142 – 116 162 162 C 104 71 102 104 98 150 150 E 232 215 233 232 226 Round Round F 232 215 232 232 244 194 199 I 203 171 205 205 202 220 223 K 213 180 219 219 209 216 216 M 49 FA = Free air ML = Maximum load Part No. D2E133DM4701-CT0 D2E133AM8398-CT0 D2E146AP4722-CT0 D4E146AA0702-CT0 D3G146LV1330-CT1 D2E146HS9704-CT1 D2E146HT6701-CT1 Nominal Voltage V 230 230 230 230 200-240 230 230 Frequency Hz 50 50 50 50 50/60 50 50 Airflow at 0Pa m3/hr 760 705 970 835 1155 760 1060 Nominal Data at ML FA ML FA FA FA ML Speed Radial Fans RPM 1650 1500 2050 1000 1550 1350 1850 Power Input W 175 185 300 100 167 195 355 Current Draw A 0.78 0.81 1.31 0.44 1.3 0.86 1.55 Sound Pressure Level at 1m dB(A) 58 60 63 55 61 57 66 Max. Perm. Amb. Temperature °C 40 35 30 50 60 45 55 Capacitor μF/V 3.0/450 3.0/500 8.0/400 2.0/450 – 5.0/400 (P2) 8.0/450 (P2) Approximate Weight kg 3.8 3.7 4.4 3.3 2.9 3.4 3.44 Wiring Diagram A1 ebm-5-speed A1 A1 H6 ebm-4-speed ebm-4-speed AC AC AC AC EC AC AC Motor Type K M F A A Radial Fans Forward Curved - Fan Coil Unit F EC Part No. K3G146AD0101 Dimensions Case Style A A 677 C 116 E 98 F 226 K 202 M 209 51 ML = Maximum load Part No. K3G146AD0101 V 200-240 Nominal Voltage Hz 50/60 Frequency m3/hr 2295 Airflow at 0Pa Radial Fans ML Nominal Data at RPM 1400 Speed W 243 Power Input A 1.8 Current Draw dB(A) 63 Sound Pressure Level at 1m °C 40 Max. Perm. Amb. Temperature kg 4.2 Approximate Weight H6 Wiring Diagram EC Motor Type 104 94 44 87 ebm papst 105 92 63 52.5 MIN WATER 57 MAX WATER 135 157 3 4.5mm FIXING HOLE 30 81 NOTE: ALL DIMENSIONS ARE IN mm 20 OUTLET SUITABLE FOR 20mm PVC HOSE PUMP MODEL ON SIDE OF CASE MOUNTING PLATE MOTOR DIAMETER LEAD LENGTH 1000 mm Pumps Evaporative Cooler 225 53 Part No. EBM ALPHA-CT0 V 240 Nominal Voltage Hz 50 Frequency Pumps RPM 2700 Speed W 50 Power Input L/s 32 Flow rate at 1m head L/s 25 Flow rate at 2 m head kg 1.4 Approximate Weight AC Motor Type High Temperature Applications Oven Fans / Heaters R2K150 55 Fa = Free air ML = Maximum lead *RLA108/0034A76 replaces G2K 108AA0145 & 46 Part No. R2K150AC0325 RLA108/0034A76* RLA97/4200-3030LH Article Number HiTemp 55466.32180 55461.21760 55465.12040 Nominal Voltage V 230 230 230 Frequency Hz 50 50 50 Airflow at 0Pa m3/hr 200 162 108 Speed RPM 2000 2520 2520 Power Input W 32 54 28 Current Draw A 0.27 n/a n/a Max. Perm. Amb. Temperature °C 120 105/150 90/220 Approximate Weight kg 0.9 1.5 3 AC AC AC Motor Type A D B Control Equipment Controllers / Sensors E C • Head Pressure Controller for refrigeration systems • Temperature Sensor for easy temperature control • Differential pressure controller for pressure measurement or closed loop pressure control • Data Center Fan Controller Kit for complete pressure control • EC Fan Gateway for monitoring and incorporation in BACnet Building Management System (BMS) • EC Fan Display for easy monitoring Bringing our systems approach to the next level, we now introduce our connECtor range. The connECtor range makes the best use of already existing features of our GreenTech EC products and is perfectlysuited for industries like refrigeration, ventilation, air conditioning, information technology, data centres, agriculture and more. The connECtor range helps monitor, control and measure your fan system. Our always expanding connECtor range currently includes the following products: ebm-papst's GreenTech EC technology offers all-inclusive air movement from one supplier. Our EC products come with everything you need: PID control amplifier, interference suppression filter, power filter, motor protection and a power supply for external sensors. That’s how easy it is with “Plug & Play”. 57 BACnet Gateway Generation II Fan condition monitor and Auto addressing MODBUS display with speed setting 240VAC switch 3 speed controller Head pressure sensor range 4 to 12.5 bar Head pressure sensor range 10 to 21 bar Head pressure sensor range 12 to 28 bar Temperature sensor range +10°C to +45°C Temperature sensor range +30°C to +55°C Differential air pressure controller range 0 to 500 Pa Differential air pressure controller range 0 to 4000 Pa 10 kΩ potentiometer with housing ECCN02-CT0 ECCN03-CT0 ECCN04-CT0 ECCN05-CT0 PRESS12-CT0 PRESS21-CT0 PRESS28-CT0 50010-1-0174 50011-1-0174 DPC200-EP500-001 DPC200-EP4000-001 CLC000AE0401 Controls Data centre controller with 0-50Pa pressure sensors Data centre controller with potentiometer Description Part No. ECCN01-CT0 ECCN01-CT1 Type – – – A A A B B D D C E E E Nominal Voltage 20 to 38VDC/24VAC 20 to 38VDC/24VAC 20 to 38VDC/24VAC 10 VDC 10 VDC 10 VDC 10 VDC 10 VDC 10-30 VDC 10-30 VDC 10 VDC 24VDC/24VAC V 20 to 38VDC/24VAC 20 to 38VDC/24VAC Application guide available via QR code on the controller Application guide available via QR code on the controller Connect and control Modbus capable fans to BACnet BMS via High Level Interface – – – Suitable for refrigerant R-134A Suitable for refrigerant R-407C/R-404A/R-507 Suitable for refrigerant R-410A – – Can act as a sensor or stand-alone controller Can act as a sensor or stand-alone controller Use for manual adjustment of speed Comment Dynamic Pressure (Pfd) Pa 0.60 0.94 1.35 1.84 2.40 3.04 3.75 4.54 5.40 6.34 7.35 8.44 9.6 10.8 12.2 13.5 Velocity (v) m/s 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 m/s 5.00 5.25 5.50 5.75 6.00 6.25 6.50 6.75 7.00 7.25 7.50 7.75 8.00 8.25 8.50 8.75 Velocity (v) Pa 15.0 16.5 18.2 19.8 21.6 23.4 25.4 27.3 29.4 32 34 36 38 41 43 46 Dynamic Pressure (Pfd) m/s 9.00 9.25 9.50 9.75 10.0 12.5 15.0 17.5 20.0 22.5 25.0 27.5 30.0 40.0 45.0 50.0 Velocity (v) Technical Information Dynamic Pressure - Air velocity chart at 20°C ambient temperature Pa 49 51 54 57 60 94 135 184 240 304 375 454 735 960 1215 1500 Dynamic Pressure (Pfd) 59 Tech Info n2 qv2 = qv1 __ n1 The air volume qv changes proportionally to the speed n: Technical Information Hooke's Law for Fans n2 pfs2 = pfs1 __ n1 2 ( ) The static pressure pfs changes proportionally to the square of the speed n: 3 ( ) n2 P2 = P1 __ n1 The input power P changes proportionally to the third power of the speed n: • Water action from condensation • Maximum relative humidity (%): 100 • Corrosion requirements: Yes • Example application: Refrigerated display case at a supermarket • Maximum relative humidity (%): ≤ 95 • Corrosion requirements: No • Example application: Condensing technology H1 (moist) • No water action, no condensation H0 (dry) Technical Information Humidity Classes • Example application: Outdoor condenser without rain protection • Corrosion requirements: Yes • Maximum relative humidity (%): 100 • Direct water exposure such as rain, snow and ice H2 (wet) 61 Diagrams Tech Info Please check our website www.ebmpapst.com.au or catalogue for complete wiring information. Notes 1. BE CAREFUL – always check the data on the motor, if in doubt ask an ebm-papst A&NZ representative 2. 3 phase – change direction of rotation by changing any 2 phases (applies for AC motors only, not EC) 3. All connection leads brought out by ebm-papst are ‘internal leads’ as defined by EN 60335-1 4. ‘PE’ = Earth The following information applies generally, but not exhaustively, to the majority of AC products sold in Australia & New Zealand. Wiring Diagrams AC Wiring Connection Diagrams U1 PE C U2 Z N A1. Single phase capacitor motor with TOP wired internally TOP L 1 ~ 230 VAC power line U1 = blue U2 = black Z = brown = green/ yellow Wiring Diagrams AC Wiring Connection Diagrams U1 PE C U2 Z N TOP A2a. Single phase capacitor motor with connection for external TOP L U1 = blue U2 = black Z = brown = green/ yellow 63 N PE Z U2 C TOP TOP Diagram A2b. Single phase capacitor motor with connection for external TOP Fans with terminal box L U 1 ~ 230 VAC power line U1 = blue U2 = black Z = brown = green/ yellow PE B. Shaded pole motor with TOP wired internally TOP L N L N = blue = brown = green/ yellow V2 U2 W L2 W2 L C1. Delta Connection (3 ~ 230 VAC power system) without TOP V L U PE 1 speed 3 ~ 230 VAC power line U1 U2 V1 V2 W1 W2 = = = = = = = black green blue white brown yellow green/ yellow Wiring Diagrams AC Wiring Connection Diagrams U2 U L V2 V W2 W L2 L C2. Star connection (3 ~ 400 VAC power system) without TOP PE 1 speed 3 ~ 400 VAC power line U1 U2 V1 V2 W1 W2 = = = = = = = black green blue white brown yellow green/ yellow 65 V2 U2 W1 L2 W2 L3 TOP Diagram D1. Delta Connection (3 ~ 230 VAC power line) with TOP V1 L1 U1 PE 1 speed 3 ~ 230 VAC power line U1 U2 V1 V2 W1 W2 = = = = = = = black green blue white brown yellow green/yellow U2 U1 L1 V2 V1 W2 W1 L2 L3 TOP D2. Star connection (3 ~ 400 or 480 VAC power line) with TOP PE 1 speed 3 ~ 400 or 480 VAC power line U1 U2 V1 V2 W1 W2 = = = = = = = black green blue white brown yellow green/yellow V V2 U2 L U PE W L2 W2 L TOP U1 U2 V1 V2 W1 W2 = = = = = = = Direction of rotation is reversed by swapping 2 line phases F1a. Delta Connection (high speed) with TOP Δ 2 speeds via Δ / λ-switch 3 ~ 400 VAC power line black green blue white brown yellow green/ yellow Wiring Diagrams AC Wiring Connection Diagrams U2 U L F2a. Star connection (low speed) with TOP PE V2 V W2 W L2 L TOP U1 U2 V1 V2 W1 W2 = = = = = = = black green blue white brown yellow green/ yellow 67 Diagram F1b. Delta Connection (high speed) with TOP Fans with terminal box L L2 L U V W W2 U2 V2 TOP TOP PE 2 speeds via Δ / Y-switch 3 ~ 400 VAC power line U1 U2 V1 V2 W1 W2 = = = = = = = black green blue white brown yellow green/ yellow F2b. Star connection (low speed) with TOP Fans with terminal box L L2 L U V W W2 U2 V2 TOP TOP PE U1 U2 V1 V2 W1 W2 = = = = = = = black green blue white brown yellow green/ yellow ebm 3 Single phase 3 speed green/yellow bl blue br brown gb yellow SW2 black #2 SW3 black #3 SW5 black #5 ebm 2 Single phase 2 speed Rotation speed fast (level II) Rotation speed slow (level I) Wiring Diagrams AC Wiring Connection Diagrams 69 Single phase 5 speed bl blue br brown ge yellow SW1 white SW2 red SW3 grey SW4 orange SW5 black Single phase 4 speed control Connection Diagram When changing speeds, the switch must break the circuit Diagram ebm 5 ebm 4 See publication/downloads at ebmpapst.com.au – Electr. connection: ESM 115 or 230 VAC L or N Speed selection Power system: 115 or 230 VAC, 50/60 Hz Wiring Diagrams AC Wiring Connection Diagrams l rt brown blue black N L1 5 2 1 Energysaving motor (ESM) 71 Diagram H3 H4 K1 L1 L2 L5 L6 L7 RP1 (previously M3) RP2 (previously M5) RP3 (previously P5) RP6 Wiring Type Power Supply 1~ 230V 50/60Hz 1~ 230V 50/60Hz 1~ 230V 50/60Hz 1~ 230V 50/60Hz 3~ 400V 50/60Hz 3~ 400V 50/60Hz 3~ 400V 50/60Hz 1~ 230V 50/60Hz 3~ 400V 50/60Hz 3~ 400V 50/60Hz 1~ 230V 50/60Hz 3~ 400V 50/60Hz Wiring Diagrams EC Wiring Connection Diagrams Description Two speed selectable 0-10V speed control 0-10V speed control EC Gen I control interface EC Gen I control interface EC Gen II control interface EC Gen I control interface EC Gen I control interface EC Gen II control interface EC Gen II control interface EC Gen II control interface EC Gen III control interface Alarm Relay No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Bus Interface No No No ebmBUS ebmBUS MODBUS MODBUS MODBUS MODBUS MODBUS MODBUS MODBUS New Zealand Unit H, 61 Hugo Johnston Drive Penrose Auckland 1061 Phone +64 (9) 525 0245 all_nzsales@au.ebmpapst.com New South Wales Unit 13, 19 Aero Road Ingleburn NSW 2565 Phone +61 (02) 9827 6400 sales@ebmpapst.com.au ebm-papst A&NZ Pty Ltd Victoria 10 Oxford Road Laverton North VIC 3026 Phone +61 (03) 9360 6400 sales@ebmpapst.com.au www.ebmpapst.com.au www.ebmpapst.co.nz 2019-05