Wood Beam (ASD) (version 98) — Floor Joist Created with ClearCalcs.com Client: Kate Date: Jun 25, 2021 Author: Mirko Restovic Job #: 002-2021 Project: Kate and Craig Fawcett Subject: B1 (Calculation Group 1) References: NDS 2018 (ASD) Summary Design Conditions M = 2190 lb ⋅ ft Allowable Bending Moment 13% Allowable Shear V ′ = 1970 lb 7% Allowable Bearing Load R′ = 3810 lb 4% Governing Live / Short-Term Combinations Cross-Sectional Area Strong Axis Moment of Inertia Section Modulus Critical Live / Short-Term (L/)ST = 9340 Deflection Ratio δ LT = −0.0105 in Governing Long-Term Deflection Governing Simplified DL+LL Critical Simplified DL+LL Deflection Ratio I xx = 178 in 4 S = 31.6 in 3 F b = 1600 psi Base Allowable Shear Stress F v = 175 psi Allowable Stress δ DL+LL = −0.012 in Deflection A = 16.9 in 2 Base Allowable Bending Stress Base Perpendicular Compression (L/)LT = 8020 Critical Long-Term Deflection Ratio International Building Code (IBC) 2018 Member Properties δ ST = −0.00899 in Deflection 3% Design Code for Load ′ 20% 3% PASS Base Modulus of Elasticity F c⊥ = 565 psi E = 1 800 000 psi Elastic Modulus (NDS 2018 2.3) (L/)DL+LL = 7020 Adjusted Modulus of Elasticity E ′ = 1 800 000 psi Section Bending (NDS 2018 2.3) Reactions: Size Factor Incising Factor Bearing: 6 in FactMax: 248 lb FactMin: 36.9 lb D: 61.6 lb L: 187 lb 0.0 Bearing: 4.5 in FactMax: 248 lb FactMin: 36.9 lb D: 61.6 lb L: 187 lb 1.0 2.0 3.0 4.0 5.0 6.0 7.0 Distance from Left of Beam (ft) Ci,b = 1 Positive Bending (NDS 2018 2.3) Governing Duration Factor Positive Bending Governing Beam Stability Factor Positive Bending Adjusted Bending Strength - Key Properties CF ,b = 1 Positive Bending + CD,b = 1 CL+ = 0.452 F b′+ = 831 psi Negative Bending (NDS 2018 2.3) Primary Loading Governing Duration Factor Negative Bending d=11.3 in Governing Beam Stability Factor Negative Bending Adjusted Bending Strength Negative Bending b=1.5 in − CD,b = 0.9 CL− = 1 F b′− = 1660 psi Shear Design (NDS 2018 3.4) Member 2x12 SYP SS LX = 7 ft Beam Plan Length Continuous Bracing for Lateral Torsional Buckling Bottom braced Loads Governing Duration Factor CD = 1 Adjusted Shear Strength F v′ = 175 psi Bearing (NDS 2018 3.10) Base Bearing Strength ′ F c⊥ /Cb = 565 psi Comments D: 13.3 plf L: 53.3 plf 7 ft Floor Load LW: 1.33 ft | D: 10 psf, L: 40 psf 0 0.0 D: 4.26 plf 7 ft Self-weight 0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 Distance from Left of Beam (ft) 1