24.00m stand boundary FLOORS CHROMADECK ROOF SHEETS G NGL Precasted /prestressd reinforced concrete lintols NGL INTERIOR WEST ELEVATION : ∅100mm gew/pvc sewer drain @1;60 fall to drain line into septic tank & soak away Standard pressed steel window frame scale 1:100 3m building line scale 1:100 NORTH ELEVATION : Standard cill bricks 150x150x20 window cills Brickwall DPC R.W 100mm diameter p.v.c. drain fall 1:60 MH Internal smooth cement plaster 4680 Minimum 3m building line RW PROPOSED OUT-BUILDING dpc NGL 450mm I.L. 100mm diameter p.v.c. drain fall 1:60 MH dpc G RW NGL 10830 Finishes to rooms as indicated on floor plans. 300x300mm non-slip ceramic floor tiles to toilets and bathrooms and kitchen. Ground floor slab on damp proof membraine (polythen)on 20mm sand binding on back fill to structural Eng's specifications and approval. All back fill to receive anti-proof treatment and guarantee certificate to be issued by specialist. s.v.p CHROMADECK ROOF SHEETS 230 scale 1:100 ROOF 115 1925 230 3400 1820 B.I.W 230 PORCH ab RC BEAMS TO ENGINEER'S DETAIL 1925 4155 115 10170 D4F Area 78.6sqm CLIENT: MR. W. KARUWO LM DRAFTING DESIGN Architectural ∞ Structural ∞ Mechanical ALL RIGHTS RESERVED. NO REPRODUCTION UNLESS WRITTEN CONSENT GIVEN p: m: w: +263772217120 lmdrafting@gmail.com www.lmdrafting.com 690 575 FOUNDATION: 690x230 concrete strip footing to take 230mm brickwork, 115 ROOM VENTILATION A Minimum of four airvents per room, exact positioning to be to builder's discretion. Rooms without direct external ventilation to have either perforated trap door or egg-crate ceiling or preferably mechanical ventilation to be used. 575 x 230mm under 115mm internal partitions. Depth to be determined by site conditions- min 700mm. Brickwork under DPC to have brickforce every 2 courses. 24.00m stand boundary STRUCTURAL WORK TO BE DONE AND SUPERVISED BY A STRUCTURAL ENGINEER MATERIALS SHALL BE THE BEST OF THEIR RESPECTIVE KINDS DESCRIBED ON THE DRAWINGS AND THE CONTRACTOR SHALL WHERE REQUIRED HEREIN OR UPON REQUEST OF THE ARCHITECT OR ENGINEER FURNISH VOUCHERS TO PROVE THAT THE MATERIALS COMPLY HEREWITH 12m R O A D SECTION A-A scale 1:100 SITE PLAN SCALE 1 : 200 NOTES ALL MEASUREMENTS IN MILLIMETRES UNLESS OTHERWISE STATED. 6280 N 12000 7725 2100 2740 1005 115 4150 12mm plasterboard ceiling nailed to 38x38mm timber battens fixed to underside of the beams trusses -tyro leon plaster finish with 150mm smooth margins. -100mm wood crown moulding cornice. -3 coats external pva ceiling paint. 10m building line 230 115 scale 1:100 NGL 100mm concrete floor slab on 150mm hardcore on well compacted fill 690 ab ab dpc dpc 3400 FLOOR PLAN : DESIGNED & DRAWN BY: 115 1515 (tiles) ab 230 D4F BEDROOM 2 (tiles) Bedroom 1 NGL CEILING 230 355 Bedroom 2 115 3000 (tiles) 1370 1200 Hall 230 370 ab C22F 1095 600 115 BATH ab D4F ab ab 115 D4F (tiles) B.I.W 1115 1.2m Arch over LOUNGE / DINING 2000 SEPTIC TANK AND SOAKAWAY 1.2 m Arch over 1770 1500 308 4056 1285 115 1095 2348 plasterboard ceilings (tiles) FLD Arc over ROOF TIMBER BY SPECIALISTS BEDROOM 1 curtain shower ab 21° 860 Pitch 21° Chromadek roofing sheets 76 x 52mm purlins -on-edge on prefab trusses by specialist on 115 x 38mm wall plate secured by stout hoop iron straps built 5 courses into brickwork. Eaves to be min.850mm.All fascia and barge board min.228 x 38mm for painting matt enamel .All gambrel vents to be fixed louver ex- varnished teak or equal approved hardwood ab KITCHEN ab ab tub (tiles) 7725 ab ab RW 230 E4 115 Fittings C2F 230 ab ab G WC 3094 C2F 230 A 100mm diameter p.v.c. drain fall 1:60 ab Above DPC, brickforce every four courses. Prestressed lintols over door and window openings. External brickwork woodfloat sand/cement render to take two coats external PVA paint.Kitchen and bathroom areas to have white-glazed wall tile to door head + render and set + pva. All other rooms render and set to take two coats external quality pva. 230 700 300 Min. 115 4155 BRICKWORK STAND 1885 EAST ELEVATION : scale 1:100 3m building line SOUTH ELEVATION : 10170 230 NGL NGL 52.00m stand boundary NGL NGL ab All water taps to be cobra or equal approved. All toilet pans and cisterns to be white dpc STAND 909 dpc STAND 1884 DRAINLAYER/PLUMBER : MAIN HOUSE 100mm diameter p.v.c. drain fall 1:60 Scale 1:20 52.00m stand boundary window/cill detail THIS DRAWING IS TO BE READ AND UNDERSTOOD IN CONJUNCTION WITH STRUCTURAL, MECHANICAL, ELECTRICAL AND/ OR ANY OTHER CONSULTANT / s DOCUMENTATION AS MAY BE APPLICABLE TO THE PROJECT PRIOR TO START OF WORKS ITS DURATION. PROPOSED OUT-BUILDING AT STAND No. 1884, BAOBAB NORTH HWANGE SCALE AS MUCH AS POSSIBLE THE BUILDER IS SUPPOSED TO COMPLY WITH THE LOCAL BUILDING INSPECTOR'S DIRECTIVES AS SET OUT IN THE M.B.B.L. OR UNDER LOCAL AUTHORITY'S BY-LAWS. DRAWN 1:100 1:200 LM 1:20 DATE CHECKED 18/08/2020 KM JOB-DRAWING No. WK/08/20 REVISION A A3