Uploaded by lameck murima

1599738721773 KARUWO-Model

24.00m stand boundary
FLOORS
CHROMADECK ROOF SHEETS
G
NGL
Precasted /prestressd
reinforced concrete lintols
NGL
INTERIOR
WEST ELEVATION :
∅100mm gew/pvc sewer drain @1;60
fall to drain line into septic tank & soak
away
Standard pressed steel window frame
scale 1:100
3m building line
scale 1:100
NORTH ELEVATION :
Standard cill bricks
150x150x20 window cills
Brickwall
DPC
R.W
100mm diameter p.v.c. drain fall 1:60
MH
Internal smooth cement plaster
4680
Minimum
3m building line
RW
PROPOSED
OUT-BUILDING
dpc
NGL
450mm I.L.
100mm diameter p.v.c. drain fall 1:60
MH
dpc
G
RW
NGL
10830
Finishes to rooms as indicated on floor plans.
300x300mm non-slip ceramic floor tiles to toilets
and bathrooms and kitchen.
Ground floor slab on damp proof membraine
(polythen)on 20mm sand binding on back fill to
structural Eng's specifications and approval.
All back fill to receive anti-proof treatment and
guarantee certificate to be issued by specialist.
s.v.p
CHROMADECK ROOF SHEETS
230
scale 1:100
ROOF
115
1925
230
3400
1820
B.I.W
230
PORCH
ab
RC BEAMS TO ENGINEER'S DETAIL
1925
4155
115
10170
D4F
Area 78.6sqm
CLIENT:
MR. W. KARUWO
LM DRAFTING DESIGN
Architectural ∞ Structural ∞ Mechanical
ALL RIGHTS RESERVED. NO REPRODUCTION UNLESS WRITTEN CONSENT GIVEN
p:
m:
w:
+263772217120
lmdrafting@gmail.com
www.lmdrafting.com
690
575
FOUNDATION:
690x230 concrete strip footing to take 230mm brickwork,
115
ROOM VENTILATION
A
Minimum of four airvents per room, exact positioning to be to builder's
discretion. Rooms without direct external ventilation to have either
perforated trap door or egg-crate ceiling or preferably mechanical
ventilation to be used.
575 x 230mm under 115mm internal partitions.
Depth to be determined by site conditions- min 700mm.
Brickwork under DPC to have brickforce every 2 courses.
24.00m stand boundary
STRUCTURAL WORK TO BE DONE AND SUPERVISED BY A STRUCTURAL ENGINEER
MATERIALS SHALL BE THE BEST OF THEIR RESPECTIVE KINDS
DESCRIBED ON THE DRAWINGS AND THE CONTRACTOR SHALL
WHERE REQUIRED HEREIN OR UPON REQUEST OF THE ARCHITECT
OR ENGINEER FURNISH VOUCHERS TO PROVE THAT THE
MATERIALS COMPLY HEREWITH
12m R O A D
SECTION A-A
scale 1:100
SITE PLAN
SCALE 1 : 200
NOTES
ALL MEASUREMENTS IN MILLIMETRES UNLESS OTHERWISE STATED.
6280
N
12000
7725
2100
2740
1005
115
4150
12mm plasterboard ceiling nailed to 38x38mm
timber battens fixed to underside of the beams trusses
-tyro leon plaster finish with 150mm smooth margins.
-100mm wood crown moulding cornice.
-3 coats external pva ceiling paint.
10m building line
230
115
scale 1:100
NGL
100mm concrete floor slab
on 150mm hardcore
on well compacted fill
690
ab
ab
dpc
dpc
3400
FLOOR PLAN :
DESIGNED & DRAWN BY:
115
1515
(tiles)
ab
230
D4F
BEDROOM 2
(tiles)
Bedroom 1
NGL
CEILING
230
355
Bedroom 2
115
3000
(tiles)
1370
1200
Hall
230
370
ab
C22F
1095
600
115
BATH
ab
D4F
ab
ab
115
D4F
(tiles)
B.I.W
1115
1.2m Arch over
LOUNGE / DINING
2000
SEPTIC TANK AND SOAKAWAY
1.2 m Arch over
1770
1500
308
4056
1285 115
1095
2348
plasterboard ceilings
(tiles)
FLD
Arc over
ROOF TIMBER BY SPECIALISTS
BEDROOM 1
curtain
shower
ab
21°
860
Pitch 21°
Chromadek roofing sheets
76 x 52mm purlins -on-edge on prefab trusses by
specialist on 115 x 38mm wall plate secured by stout
hoop iron straps built 5 courses into brickwork.
Eaves to be min.850mm.All fascia and barge board min.228 x 38mm for
painting matt enamel .All gambrel vents to be fixed louver
ex- varnished teak or equal approved hardwood
ab
KITCHEN
ab
ab
tub
(tiles)
7725
ab ab
RW
230
E4
115
Fittings
C2F
230
ab ab G
WC
3094
C2F
230
A
100mm diameter p.v.c. drain fall 1:60
ab
Above DPC, brickforce every four courses. Prestressed
lintols over door and window openings.
External brickwork woodfloat sand/cement render to take
two coats external PVA paint.Kitchen and bathroom areas
to have white-glazed wall tile to door head + render and
set + pva. All other rooms render and set to take two
coats external quality pva.
230 700 300
Min.
115
4155
BRICKWORK
STAND 1885
EAST ELEVATION :
scale 1:100
3m building line
SOUTH ELEVATION :
10170
230
NGL
NGL
52.00m stand boundary
NGL
NGL
ab
All water taps to be cobra or equal approved.
All toilet pans and cisterns to be white
dpc
STAND 909
dpc
STAND 1884
DRAINLAYER/PLUMBER :
MAIN HOUSE
100mm diameter p.v.c. drain fall 1:60
Scale 1:20
52.00m stand boundary
window/cill detail
THIS DRAWING IS TO BE READ AND UNDERSTOOD IN
CONJUNCTION WITH STRUCTURAL, MECHANICAL, ELECTRICAL
AND/ OR ANY OTHER CONSULTANT / s DOCUMENTATION AS MAY
BE APPLICABLE TO THE PROJECT PRIOR TO START OF WORKS
ITS DURATION.
PROPOSED OUT-BUILDING AT STAND No. 1884,
BAOBAB NORTH
HWANGE
SCALE
AS MUCH AS POSSIBLE THE BUILDER IS SUPPOSED TO COMPLY
WITH THE LOCAL BUILDING INSPECTOR'S DIRECTIVES AS SET OUT
IN THE M.B.B.L. OR UNDER LOCAL AUTHORITY'S BY-LAWS.
DRAWN
1:100 1:200
LM
1:20
DATE
CHECKED
18/08/2020
KM
JOB-DRAWING No.
WK/08/20
REVISION
A
A3